Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software differences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

TH-C-BRD-06: A Novel MRI Based CT Artifact Correction Method for Improving Proton Range Calculation in the Presence of Severe CT Artifacts

Purpose: Severe CT artifacts can impair our ability to accurately calculate proton range thereby resulting in a clinically unacceptable treatment plan. In this work, we investigated a novel CT artifact correction method based on a coregistered MRI and investigated its ability to estimate CT HU and proton range in the presence of severe CT artifacts. Methods: The proposed method corrects corrupted CT data using a coregistered MRI to guide the mapping of CT values from a nearby artifact-free region. First patient MRI and CT images were registered using 3D deformable image registration software based on B-spline and mutual information. The CT slice with severe artifacts was selected as well as a nearby slice free of artifacts (e.g. 1cm away from the artifact). The two sets of paired MRI and CT images at different slice locations were further registered by applying 2D deformable image registration. Based on the artifact free paired MRI and CT images, a comprehensive geospatial analysis was performed to predict the correct CT HU of the CT image with severe artifact. For a proof of concept, a known artifact was introduced that changed the ground truth CT HU value up to 30% and up to 5cm error in proton range. The ability of the proposed method to recover the ground truth was quantified using a selected head and neck case. Results: A significant improvement in image quality was observed visually. Our proof of concept study showed that 90% of area that had 30% errors in CT HU was corrected to 3% of its ground truth value. Furthermore, the maximum proton range error up to 5cm was reduced to 4mm error. Conclusion: MRI based CT artifact correction method can improve CT image quality and proton range calculation for patients with severe CT artifacts.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-I-01: EIT Imaging to Monitor Human Salivary Gland Functionality: A Feasibility Study

Purpose: Clinically, there exists a need to develop a non-invasive technique for monitoring salivary activity. In this study, we investigate the feasibility of a using the electrical conductivity information from Electrical Impedance Tomography (EIT) to monitor salivary flow activity. Methods: To acquire EIT data, eight Ag/AgCl ECG electrodes were placed around the mandible of the subject. An EIT scan was obtained by injecting current at 50 KHz, 0.4 mA through each pair of electrodes and recording voltage across other electrode pairs. The functional conductivity image was obtained through reconstruction of the voltage data, using Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software (EIDORS) in Matlab. In using EIDORS, forward solution was obtained using a user-defined finite element model shape and inverse solution was obtained using one-step Gaussian solver. EIT scans of volunteer research team members were acquired for three different physiological states: pre-stimulation, stimulation and post-stimulation. For pre-stimulation phase, data were collected in intervals of 5 minutes for 15 minutes. The salivary glands were then stimulated in the subject using lemon and the data were collected immediately. Post-stimulation data were collected at 4 different timings after stimulation. Results: Variations were observed in the electrical conductivity patterns near parotid regions between the pre- and post-stimulation stages. The three images acquired during the 15 minute pre-stimulation phase showed no major changes in the conductivity. Immediately after stimulation, electrical conductivity increased near parotid regions and 15 minutes later slowly returned to pre-stimulation level. Conclusion: In the present study involving human subjects, the change in electrical conductivity pattern shown in the EIT images, acquired at different times with and without stimulation of salivary glands, appeared to be consistent with the change in salivary gland activity. The conductivity changes imaged through EIT are potentially useful for the purpose of salivary monitoring.

60 APPLIED LIFE SCIENCES↗

Sandia Generated Matrix Tool (SGMT) v. 1.0

Provides a tool with which create and characterize a very large set of matrix-based visual analogy problems that have properties that are similar to Raven's Progressive Matrices (RPMs)™. The software uses the same underlying patterns found in RPMs to generate large numbers of unique matrix problems using parameters chosen by the researcher. Specifically, the software is designed so that researchers can choose the type, direction, and number of relations in a problem and then create any number of unique matrices that share the same underlying structure (e.g. changes in numerosity in a diagonal pattern) but have different surface features (e.g. shapes, colors).Raven's Progressive Matrices (RPMs) ™ are a widely-used test for assessing intelligence and reasoning ability. Since the test is non-verbal, it can be applied to many different populations and has been used all over the world. However, there are relatively few matrices in the sets developed by Raven, which limits their use in experiments requiring large numbers of stimuli. This tool creates a matrix set in a systematic way that allows researchers to have a great deal of control over the underlying structure, surface features, and difficulty of the matrix problems while providing a large set of novel matrices with which to conduct experiments.

Benz, Zachary↗

AMReX v2024

The software framework, AMReX, supports the development of block-structured adaptive mesh refinement (AMR) algorithms for solving systems of partial differential equations. AMR reduces the computational cost and memory footprint compared to a uniform mesh while preserving the essential local descriptions of different physical processes in complex multiphysics algorithms. AMR uses a hierarchical representation of the solution at multiple levels of resolution where the solution on each level is defined on the union of data containers at that resolution. These data containers, which represent the solution over a logically rectangular subregion of the domain, can contain field data defined on a mesh, Lagrangian particles or combinations of both. In addition to these basic data types, AMReX supports a multilevel embedded boundary representation of complex geometry; linear solvers for cell-centered and nodal data; asynchronous I/O in a native format readable by ParaView, VisIt and yt; and interfaces to hypre and PETSc solvers. AMReX enables applications to run on distributed memory architectures with multicore CPUs and with GPU accelerators. AMReX uses a lightweight abstraction layer that effectively hides the details of the architecture from the application. The framework currently supports CUDA, HIP and SYCL for GPU acceleration and OpenMP for multi-core CPU architectures.

Almgren, Ann↗

Multiyear Plan for Validation of EnergyPlus Multi-Zone HVAC System Modeling using ORNL's Flexible Research Platform

This document describes the Oak Ridge National Laboratory (ORNL) multiyear experimental plan for validation and uncertainty characterization of whole-building energy simulation for a multi-zone research facility using a traditional rooftop unit (RTU) as a baseline heating, ventilating, and air conditioning (HVAC) system. The project’s overarching objective is to increase the accuracy of energy simulation tools by enabling empirical validation of key inputs and algorithms. Doing so is required to inform the design of increasingly integrated building systems and to enable accountability for performance gaps between design and operation of a building. The project will produce documented data sets that can be used to validate key functionality in different energy simulation tools and to identify errors and inadequate assumptions in simulation engines so that developers can correct them. ASHRAE Standard 140, Method of Test for the Evaluation of Building Energy Analysis Computer Programs (ASHRAE 2004), currently consists primarily of tests to compare different simulation programs with one another. This project will generate sets of measured data to enable empirical validation, incorporate these test data sets in an extended version of Standard 140, and apply these tests to the Department of Energy’s (DOE) EnergyPlus software (EnergyPlus 2016) to initiate the correction of any significant deficiencies. The fitness-for-purpose of the key algorithms in EnergyPlus will be established and demonstrated, and vendors of other simulation programs will be able to demonstrate the validity of their products. The data set will be equally applicable to validation of other simulation engines as well.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2014 Runtime Systems Summit. Runtime Systems Report

This report summarizes runtime system challenges for exascale computing, that follow from the fundamental challenges for exascale systems that have been well studied in past reports, e.g., [6, 33, 34, 32, 24]. Some of the key exascale challenges that pertain to runtime systems include parallelism, energy efficiency, memory hierarchies, data movement, heterogeneous processors and memories, resilience, performance variability, dynamic resource allocation, performance portability, and interoperability with legacy code. In addition to summarizing these challenges, the report also outlines different approaches to addressing these significant challenges that have been pursued by research projects in the DOE-sponsored X-Stack and OS/R programs. Since there is often confusion as to what exactly the term “runtime system” refers to in the software stack, we include a section on taxonomy to clarify the terminology used by participants in these research projects. In addition, we include a section on deployment opportunities for vendors and government labs to build on the research results from these projects. Finally, this report is also intended to provide a framework for discussing future research and development investments for exascale runtime systems, and for clarifying the role of runtime systems in exascale software.

97 MATHEMATICS AND COMPUTING↗

Upgrade of the Graphical User Interface (GUI) of otsdaq

otsdaq is a data acquisition software. The purpose of this project was to improve the design and the functionality of some features on the Graphical User Interface of otsdaq. The GUI interface is developed in HTML and JavaScript. The code is maintained on GitHub and developed by different users working on a remote machine environment.

Najjuma, Brenda↗

Extended Bandwidth Spread Spectrum Time Domain Reflectometry Cable Test for Thermal Aging, Low Resistance Fault, and Water Detection

In 2022, researchers at Pacific Northwest National Laboratory (PNNL) used the Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed to characterize spread spectrum time domain reflectometry (SSTDR) and compare the responses of an SSTDR instrument to those of a frequency domain reflectometry (FDR) instrument. Results showed both techniques could detect and locate cable anomalies such as phase-to-phase low resistance and shorts, thermal insulation damage, mechanical insulation damage, and the presence or absence of water in some conditions. The SSTDR tests used a commercial instrument provided by LiveWire Innovations Inc. This commercial instrument performed tests at 6, 12, 24, and 48 MHz bandwidth. The results of these tests were compared to FDR tests where bandwidths could be extended up to 1.3 GHz, although the best responses for cable tests were from 100 to 500 MHz. Lower bandwidth signals can propagate better along the cable while higher bandwidths have higher resolution for impedance change reflections allowing more precise indication of location and separation of anomalies. The 2022 research found that FDR responses were clearer than SSTDR and speculated that a higher bandwidth SSTDR could more successfully detect and locate cable anomalies. One advantage of the SSTDR system investigated was that it was designed for energized online use up to 1,000 volts, which may be a significant advantage for nuclear power plant use. The LiveWire SSTDR instrument is an established product in the rail and aircraft industry and updating the SSTDR hardware parameters is difficult to justify without more conclusive testing. Therefore, a software adjustable laboratory SSTDR instrument was developed by PNNL and was used to test extended bandwidth SSTDR cable tests. Within the ARENA test bed, 42 cable conditions were tested with the PNNL SSTDR, FDR, and the LiveWire SSTDR—each operating at four different bandwidths. Observations and conclusions regarding the relative performance of the three instruments over different bandwidths are note below. Responses of the PNNL SSTDR (at 50 MHz) and the LiveWire SSTDR (at 48 MHz) were similar. The PNNL SSTDR higher frequency bandwidths behaved as expected showing sharper peaks and higher noise. This validated the PNNL SSTDR as a reasonable implementation of the SSTDR technology. Lower bandwidth SSTDR responses (particularly 6 and 12 MHz) may have increased value for use within longer cables but were not particularly effective at identifying anomalous cable behavior in the 100 ft cables tested here. The higher bandwidths of the PNNL SSTDR (50, 100, 200, and 400 MHz) did not provide substantially clearer cable reflectometry responses, but having the higher frequency responses available did add to the cable test evaluation. Strong responses to shorts and low impedance faults between phases were particularly evident in the higher bandwidth PNNL SSTDR and the FDR data. Measurements were repeatable, with similar responses obtained from a thermally aged cable for tests taken a month apart. Signal noise was affected in the unshielded cable by the local in-tray cable arrangement including proximity to metal edges and rungs of the cable tray. Foam isolation of the cable from the tray metal reduced in both FDR and SSTDR responses. Cable condition monitoring in nuclear power plants will likely benefit from both more informative off-line testing methods and from the development of on-line methods for continuous monitoring of cables in use. The LWRS-funded ARENA test bed was a valuable resource for this development and direct comparison of nuclear electrical cable condition monitoring technologies. Test results are targeted to guide industry advancement of testing and monitoring tools for cable aging management.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Creating Apptainer Workflows with Docker-Compose-like Utilities

Creating Apptainer Workflows with Docker-Compose-like Utilities In this presentation, I will explore the utilization of a tool called process-compose, inspired by docker-compose, to create Apptainer-based services. This approach allows for easy deployment and management of fully containerized applications on High Performance Computing (HPC) systems without requiring elevated privileges. Benefits to the Ecosystem: By incorporating process-compose and Apptainer, I aim to address several key challenges in the HPC ecosystem: Simplified Workflow Management: Process-compose provides a user-friendly interface for defining and managing complex containerized application services, reducing the setup time and lowering the barrier to entry for new users. Enhanced Portability: Apptainer ensures that containerized applications can run consistently across different HPC environments, promoting greater portability and reducing compatibility issues. Process-compose is also a single binary that does not need to be installed by admin level users. Community Driven Solutions: This approach aligns with the goals of the High Performance Software Foundation (HPSF) to advance community-driven solutions. By sharing our experiences and insights, I hope to foster collaboration and innovation within the HPC community. Increased Productivity: The combination of process-compose and Apptainer streamlines the serve deployment process, allowing researchers and developers to focus more on their scientific work rather than the intricacies of system or service administration. Through this presentation, attendees will gain valuable insights into the practical implementation of containerized workflows on HPC systems, learn about the benefits of using process-compose and Apptainer, and understand how these tools can contribute to a more efficient HPC ecosystem.

97 - MATHEMATICS AND COMPUTING↗

Initial Process Planning of a Hybrid Multi-Tasking Platform

Abstract Applications of hybrid technology are expanding from refurbishment and repair to low quantity, specialty part production, which are staple characteristics in medical implant, energy, and aerospace industry sectors, among others. This expansion has led to the development of the Mazak VC-500A/5X AM HWD, a wire fed laser cladding unit equipped with a standard 5 axis CNC. This unit is capable of building near net geometry of complex medium to large parts within a profitable timeframe, due to its comparatively high rate of deposition to that of a powder fed hybrid system. In this study, deposition and machining capabilities of the VC-500A/5X AM HWD are assessed through the production of three different test geometries by different process plans. Production of these test geometries is supported by an open loop sensor package primarily for monitoring machine health, data collection, and machine operator aid. The viability of extended deposition followed by machining is evaluated against a more cyclical strategy of reoccurring deposition and machining operations. Lastly, common defects in as-built geometries are evaluated and addressed through revisions to original process plans and toolpaths, indicating the need for continued innovation in hybrid manufacturing specific CAM/CAD software, as well as closed loop machine monitoring and quality control.

DeWitte, Lisa N.↗

Validation of deformable image registration algorithms on CT images of ex vivo porcine bladders with fiducial markers

Purpose: The spatial accuracy of deformable image registration (DIR) is important in the implementation of image guided adaptive radiotherapy techniques for cancer in the pelvic region. Validation of algorithms is best performed on phantoms with fiducial markers undergoing controlled large deformations. Excised porcine bladders, exhibiting similar filling and voiding behavior as human bladders, provide such an environment. The aim of this study was to determine the spatial accuracy of different DIR algorithms on CT images ofex vivo porcine bladders with radiopaque fiducial markers applied to the outer surface, for a range of bladder volumes, using various accuracy metrics. Methods: Five excised porcine bladders with a grid of 30–40 radiopaque fiducial markers attached to the outer wall were suspended inside a water-filled phantom. The bladder was filled with a controlled amount of water with added contrast medium for a range of filling volumes (100–400 ml in steps of 50 ml) using a luer lock syringe, and CT scans were acquired at each filling volume. DIR was performed for each data set, with the 100 ml bladder as the reference image. Six intensity-based algorithms (optical flow or demons-based) implemented in theMATLAB platform DIRART, a b-spline algorithm implemented in the commercial software package VelocityAI, and a structure-based algorithm (Symmetric Thin Plate Spline Robust Point Matching) were validated, using adequate parameter settings according to values previously published. The resulting deformation vector field from each registration was applied to the contoured bladder structures and to the marker coordinates for spatial error calculation. The quality of the algorithms was assessed by comparing the different error metrics across the different algorithms, and by comparing the effect of deformation magnitude (bladder volume difference) per algorithm, using the Independent Samples Kruskal-Wallis test. Results: The authors found good structure accuracy without dependency on bladder volume difference for all but one algorithm, and with the best result for the structure-based algorithm. Spatial accuracy as assessed from marker errors was disappointing for all algorithms, especially for large volume differences, implying that the deformations described by the registration did not represent anatomically correct deformations. The structure-based algorithm performed the best in terms of marker error for the large volume difference (100–400 ml). In general, for the small volume difference (100–150 ml) the algorithms performed relatively similarly. The structure-based algorithm exhibited the best balance in performance between small and large volume differences, and among the intensity-based algorithms, the algorithm implemented in VelocityAI exhibited the best balance. Conclusions: Validation of multiple DIR algorithms on a novel physiological bladder phantom revealed that the structure accuracy was good for most algorithms, but that the spatial accuracy as assessed from markers was low for all algorithms, especially for large deformations. Hence, many of the available algorithms exhibit sufficient accuracy for contour propagation purposes, but possibly not for accurate dose accumulation.

60 APPLIED LIFE SCIENCES↗

Optimization of an on-board imaging system for extremely rapid radiation therapy

Purpose: Next-generation extremely rapid radiation therapy systems could mitigate the need for motion management, improve patient comfort during the treatment, and increase patient throughput for cost effectiveness. Such systems require an on-board imaging system that is competitively priced, fast, and of sufficiently high quality to allow good registration between the image taken on the day of treatment and the image taken the day of treatment planning. In this study, three different detectors for a custom on-board CT system were investigated to select the best design for integration with an extremely rapid radiation therapy system. Methods: Three different CT detectors are proposed: low-resolution (all 4 × 4 mm pixels), medium-resolution (a combination of 4 × 4 mm pixels and 2 × 2 mm pixels), and high-resolution (all 1 × 1 mm pixels). An in-house program was used to generate projection images of a numerical anthropomorphic phantom and to reconstruct the projections into CT datasets, henceforth called “realistic” images. Scatter was calculated using a separate Monte Carlo simulation, and the model included an antiscatter grid and bowtie filter. Diagnostic-quality images of the phantom were generated to represent the patient scan at the time of treatment planning. Commercial deformable registration software was used to register the diagnostic-quality scan to images produced by the various on-board detector configurations. The deformation fields were compared against a “gold standard” deformation field generated by registering initial and deformed images of the numerical phantoms that were used to make the diagnostic and treatment-day images. Registrations of on-board imaging system data were judged by the amount their deformation fields differed from the corresponding gold standard deformation fields—the smaller the difference, the better the system. To evaluate the registrations, the pointwise distance between gold standard and realistic registration deformation fields was computed. Results: By most global metrics (e.g., mean, median, and maximum pointwise distance), the high-resolution detector had the best performance but the medium-resolution detector was comparable. For all medium- and high-resolution detector registrations, mean error between the realistic and gold standard deformation fields was less than 4 mm. By pointwise metrics (e.g., tracking a small lesion), the high- and medium-resolution detectors performed similarly. For these detectors, the smallest error between the realistic and gold standard registrations was 0.6 mm and the largest error was 3.6 mm. Conclusions: The medium-resolution CT detector was selected as the best for an extremely rapid radiation therapy system. In essentially all test cases, data from this detector produced a significantly better registration than data from the low-resolution detector and a comparable registration to data from the high-resolution detector. The medium-resolution detector provides an appropriate compromise between registration accuracy and system cost.

60 APPLIED LIFE SCIENCES↗

Why Vascular Surgeons and Interventional Radiologists Collaborate or Compete: A Look at Endovascular Stent Placements

PurposeTo understand how cultural differences between vascular surgeons (VSs) and interventional radiologists (IRs) affect their clinical decision making and inter-specialty relationships.MethodsTwenty-four conversational interviews were conducted with IRs and VSs about their approaches to patient care, views of their specialty and others, and solutions to any expressed concerns. Interview transcripts were systematically analyzed to identify and compare key themes according to the constructivist grounded theory and content analysis using NVivo 10 software. These data were supplemented with a retrospective analysis of 3658 endovascular stent placements performed at a large medical academic center over 11 years. Aggregate counts were divided by provider specialty, and trends were assessed via correlation coefficients.ResultsEndovascular stent placements were relatively equally divided between IR and VS over 11 years with some variability from placements by cardiology. IRs tend to lay claim to treatments as masters of procedures, whereas VSs base their claims on being masters of the treated diseases, leading to collaboration in some practices and bitter competition in others. The level of perceived competition was most associated with specialists’ awareness of and appreciation for specialty-specific values rather than differences in practice structure/reimbursement.ConclusionsUnderstanding cultural differences between IRs and VSs is imperative for fostering better collaboration to grow shared territory rather than competing for the same slice of the pie.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Regression-Based Analytics for Response Dynamics of SDN Solutions and Components

We consider Software-Defined Network (SDN) solutions that dynamically setup and teardown connections, and also their response dynamics of connectivity and TCP throughput. There is a wide variety of choices for controllers, switches, andsoftware modules, and objective analytics of measurements are needed to compare the response dynamics of solutions based on their combinations. Throughput and ping measurements during connection changes contain significant statistical variations due to the complexities of controllers, northbound scripts, and network devices. We propose analytical methods to estimate response regression functions, which provide a rigorous and objective comparison of different SDN solutions and their components, namely, controllers, switches, and OpenFlow versions. We apply this approach in two scenarios: (a) switching of long-haul connections emulated in hardware by ANUE devices over a testbed consisting of HP and Cisco switches, and (b) multi-site science infrastructure emulated using VMs and Mininet. The results provide useful practical insights including: (i) the dpctl method responds seconds faster than the OpenDayLight (ODL) method on average under OpenFlow 1.0, but performs similar to ODL under OpenFlow 1.3, and (ii) the ping response of dpctl is about 0.6 sec faster than ODL for the second scenario.

97 MATHEMATICS AND COMPUTING↗

Modeling of wave processes in blocky media with porous and fluid-saturated interlayers

The wave processes in blocky media are analyzed by applying different mathematical models, wherein the elastic blocks interact with each other via pliant interlayers with the complex mechanical properties. Four versions of constitutive equations are considered. In the first version, an elastic interaction between the blocks is simulated within the framework of linear elasticity theory, and the model of elastic–plastic interlayers is constructed to take into account the appearance of irreversible deformation of interlayers at short time intervals. In the second one, the effects of viscoelastic shear in the interblock interlayers are taken into the consideration using the Poynting–Thomson rheological scheme. In the third option, the model of an elastic porous material is used in the interlayers, where the pores collapse if an abrupt compressive stress is applied. In the fourth case, the model of a fluid-saturated material with open pores is examined based on Biot's equations. The collapse of pores is modeled by the generalized rheological approach, wherein the mechanical properties of a material are simulated using four rheological elements. Three of them are the traditional elastic, viscous and plastic elements, the fourth element is the so-called rigid contact, which is used to describe the behavior of materials with the different resistance to tension and compression. It was shown that the thermodynamically consistent model is provided, which means that the energy balance equation is fulfilled for an entire blocky structure, where the kinetic and potential energy of the system is the sum of the kinetic and potential energies of the blocks and interlayers. Under numerical implementation of the interlayers models, the dissipationless finite difference Ivanov's method was used. The splitting method by spatial variables in the combination with the Godunov gap decay scheme was applied in the blocks. As a result, robust and stable computational algorithms are built and tested. Using MPI technology, the parallel software was designed for the modeling of wave processes in 2D setting. The numerical results are presented, discussed and future studies are outlined. - Highlights: • We model the propagation of waves in a blocky medium with compliant interlayers. • Models of porous and fluid saturated interlayers are proposed using Biot's approach. • A parallel computational algorithm is developed for supercomputers of cluster type. • Problems of instant rotation of central and boundary blocks are solved numerically. • Wave motions are compared in the cases of elastic and fluid-saturated interlayers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Initial experience of ArcCHECK and 3DVH software for RapidArc treatment plan verification

The purpose of this study was to perform delivery quality assurance with ArcCHECK and 3DVH system (Sun Nuclear, FL) and to evaluate the suitability of this system for volumetric-modulated arc therapy (VMAT) (RapidArc [RA]) verification. This software calculates the delivered dose distributions in patients by perturbing the calculated dose using errors detected in fluence or planar dose measurements. The device is tested to correlate the gamma passing rate (%GP) and the composite dose predicted by 3DVH software. A total of 28 patients with prostate cancer who were treated with RA were analyzed. RA treatments were delivered to a diode array phantom (ArcCHECK), which was used to create a planned dose perturbation (PDP) file. The 3DVH analysis used the dose differences derived from comparing the measured dose with the treatment planning system (TPS)-calculated doses to perturb the initial TPS-calculated dose. The 3DVH then overlays the resultant dose on the patient's structures using the resultant “PDP” beams. Measured dose distributions were compared with the calculated ones using the gamma index (GI) method by applying the global (Van Dyk) normalization and acceptance criteria, i.e., 3%/3 mm. Paired differences tests were used to estimate statistical significance of the differences between the composite dose calculated using 3DVH and %GP. Also, statistical correlation by means of logistic regression analysis has been analyzed. Dose-volume histogram (DVH) analysis for patient plans revealed small differences between treatment plan calculations and 3DVH results for organ at risk (OAR), whereas planning target volume (PTV) of the measured plan was systematically higher than that predicted by the TPS. The t-test results between the planned and the estimated DVH values showed that mean values were incomparable (p < 0.05). The quality assurance (QA) gamma analysis 3%/3 mm showed that in all cases there were only weak-to-moderate correlations (Pearson r: 0.12 to 0.74). Moreover, clinically relevant differences increased with increasing QA passing rate, indicating that some of the largest dose differences occurred in the cases of high QA passing rates, which may be called “false negatives.” The clinical importance of any disagreement between the measured and the calculated dose is often difficult to interpret; however, beam errors (either in delivery or in TPS calculation) can affect the effectiveness of the patient dose. Further research is needed to determinate the role of a PDP-type algorithm to accurately estimate patient dose effect.

61 RADIATION PROTECTION AND DOSIMETRY↗

MaterialsMap: A CALPHAD-based tool to design composition pathways through feasibility map for desired dissimilar materials, demonstrated with resistance spot welding joining of Ag-Al-Cu

Assembly of dissimilar metals can be achieved by different methods, for example, casting, welding, and additive manufacturing (AM). However, undesired phases formed in liquid-phase assembling processes due to solute segregation during solidification diminish mechanical and other properties of the processed parts. In the present work, an open-source software named MaterialsMap, has been developed based on the CALculation of Phase Diagrams (CALPHAD) approach. The primary objective of MaterialsMap is to facilitate the design of an optimal composition pathway for assembling dissimilar alloys with liquid-phases based on the formation of desired and undesired phases along the pathway. In MaterialsMap, equilibrium thermodynamic calculations are used to predict equilibrium phases formed at slow cooling rate, while Scheil-Gulliver simulations are employed to predict non-equilibrium phases formed during rapid cooling. Additionally, by combining these two simulations, MaterialsMap offers a thorough guide for understanding phase formation in various manufacturing processes, assisting users in making informed decisions during material selection and production. As a demonstration of this approach, a compositional pathway was designed from pure Al to pure Cu through Ag using MaterialsMap. The design was experimentally verified using resistance spot welding (RSW).

36 MATERIALS SCIENCE↗

Empirically Driven multiwavelength K-c orrections at low redshift

K -corrections – a necessary ingredient for converting between flux in observed bands to flux in rest-frame bands – are critical for comparing galaxies at differing redshifts. These corrections often rely on fits to empirical or theoretical spectral energy distribution (SED) templates of galaxies. However, templates can only produce reliable K-corrections in regimes where SED models are robust. For instance, the templates utilized in some popular software packages are not well-constrained in some bands (e.g. WISE W4 in KCORRECT ), which results in ill-behaved K -corrections. We address this shortcoming by developing an empirically driven approach to K -corrections that limits the dependence on SED templates. We perform a polynomial fit for the K -correction as a function of a galaxy’s rest-frame colour determined in a pair of well-constrained bands (e.g. 0 (g − r)) and redshift, exploiting the fact that galaxy SEDs can be approximated as a one-parameter family at low redshift. For bands well-constrained by SED templates, our empirically driven K -corrections yield results comparable to the SED fitting methods used by KCORRECT and the GSWLC-M2 catalogue (the updated medium-deep GALEX–SDSS–WISE Legacy Catalogue). However, our method dramatically outperforms Kcorrect derived K -corrections for WISE W4 . Our method is also robust to incorrect template assumptions outside of the optical bands and enforces that the K -correction must be zero at z = 0. Our K -corrected photometry and code are publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗