Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reliability analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Coupling MD Simulations and X-ray Absorption Spectroscopy to Study Ions in Solution

The structure of ionic solutions is a key-point in understanding physicochemical properties of electrolyte solutions. Among the reduced number of experimental techniques which can supply direct information on the ion environment, X-ray Absorption techniques (XAS) have gained importance during the last decades although they are not free of difficulties associated to the data analysis leading to provide reliable structures. Computer simulations of ions in solution is a theoretical alternative to provide information on the solvation structure. Thus, the use of computational chemistry can increase the understanding of these systems although an accurate description of ionic solvation phenomena represents nowadays a significant challenge to theoretical chemistry. We present: (a) the assignment of features in the XANES spectrum to well defined structural motif in the ion environment, (b) MD-based evaluation of EXAFS parameters used in the fitting procedure to make easier the structural resolution, and (c) the use of the agreement between experimental and simulated XANES spectra to help in the choice of a given intermolecular potential for Computer Simulations. Chemical problems examined are: (a) the identification of the second hydration shell in dilute aqueous solutions of highly-charged cations, such as Cr{sup 3+}, Rh{sup 3+}, Ir{sup 3+}, (b) the invisibility by XAS of certain structures characterized by Computer Simulations but exhibiting high dynamical behavior and (c) the solvation of Br{sup -} in acetonitrile.

74 ATOMIC AND MOLECULAR PHYSICS↗

Advancing the Fork detector for quantitative spent nuclear fuel verification

The Fork detector is widely used by the safeguards inspectorate of the European Atomic Energy Community (EURATOM) and the International Atomic Energy Agency (IAEA) to verify spent nuclear fuel. Fork measurements are routinely performed for safeguards prior to dry storage cask loading. Additionally, spent fuel verification will be required at the facilities where encapsulation is performed for acceptance in the final repositories planned in Sweden and Finland. The use of the Fork detector as a quantitative instrument has not been prevalent due to the complexity of correlating the measured neutron and gamma ray signals with fuel inventories and operator declarations. A spent fuel data analysis module based on the ORIGEN burnup code was recently implemented to provide automated real-time analysis of Fork detector data. This module allows quantitative predictions of expected neutron count rates and gamma units as measured by the Fork detectors using safeguards declarations and available reactor operating data. This study describes field testing of the Fork data analysis module using data acquired from 339 assemblies measured during routine dry cask loading inspection campaigns in Europe. Assemblies include both uranium oxide and mixed-oxide fuel assemblies. More recent measurements of 50 spent fuel assemblies at the Swedish Central Interim Storage Facility for Spent Nuclear Fuel are also analyzed. An evaluation of uncertainties in the Fork measurement data is performed to quantify the ability of the data analysis module to verify operator declarations and to develop quantitative go/no-go criteria for safeguards verification measurements during cask loading or encapsulation operations. The goal of this approach is to provide safeguards inspectors with reliable real-time data analysis tools to rapidly identify discrepancies in operator declarations and to detect potential partial defects in spent fuel assemblies with improved reliability and minimal false positive alarms. Finally, the results are summarized, and sources and magnitudes of uncertainties are identified, and the impact of analysis uncertainties on the ability to confirm operator declarations is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trajectory analysis of Polar Patrol Balloon (PPB) flights in the stratosphere over Antarctica in summer and spring: A preliminary result

Actual trajectories of two PPB's which flew in the Antarctic stratosphere in austral summer and spring are compared with those calculated based on objective analysis data of Japan Meteorological Agency (JMA). The differences between the actual and calculated trajectories are discussed to check reliability of the JMA objective analysis data for the stratosphere, and to detect subsynoptic scale variability due to gravity waves and others.

Kanzawa, Hiroshi↗

Reusable Solid Rocket Motor - Accomplishment, Lessons, and a Culture of Success

The Reusable Solid Rocket Motor (RSRM) represents the largest solid rocket motor (SRM) ever flown and the only human-rated solid motor. High reliability of the RSRM has been the result of challenges addressed and lessons learned. Advancements have resulted by applying attention to process control, testing, and postflight through timely and thorough communication in dealing with all issues. A structured and disciplined approach was taken to identify and disposition all concerns. Careful consideration and application of alternate opinions was embraced. Focus was placed on process control, ground test programs, and postflight assessment. Process control is mandatory for an SRM, because an acceptance test of the delivered product is not feasible. The RSRM maintained both full-scale and subscale test articles, which enabled continuous improvement of design and evaluation of process control and material behavior. Additionally RSRM reliability was achieved through attention to detail in post flight assessment to observe any shift in performance. The postflight analysis and inspections provided invaluable reliability data as it enables observation of actual flight performance, most of which would not be available if the motors were not recovered. RSRM reusability offered unique opportunities to learn about the hardware. NASA is moving forward with the Space Launch System that incorporates propulsion systems that takes advantage of the heritage Shuttle and Ares solid motor programs. These unique challenges, features of the RSRM, materials and manufacturing issues, and design improvements will be discussed in the paper.

Moore, D. R.↗

REPEATABILITY OF SPITZER/IRAC EXOPLANETARY ECLIPSES WITH INDEPENDENT COMPONENT ANALYSIS

The research of effective and reliable detrending methods for Spitzer data is of paramount importance for the characterization of exoplanetary atmospheres. To date, the totality of exoplanetary observations in the mid- and far-infrared, at wavelengths >3 μm, have been taken with Spitzer. In some cases, in past years, repeated observations and multiple reanalyses of the same data sets led to discrepant results, raising questions about the accuracy and reproducibility of such measurements. Morello et al. (2014, 2015) proposed a blind-source separation method based on the Independent Component Analysis of pixel time series (pixel-ICA) to analyze InfraRed Array Camera (IRAC) data, obtaining coherent results when applied to repeated transit observations previously debated in the literature. Here we introduce a variant to the pixel-ICA through the use of wavelet transform, wavelet pixel-ICA, which extends its applicability to low-signal-to-noise-ratio cases. We describe the method and discuss the results obtained over 12 eclipses of the exoplanet XO3b observed during the “Warm Spitzer” era in the 4.5 μm band. The final results are reported, in part, also in Ingalls et al. (2016), together with results obtained with other detrending methods, and over 10 synthetic eclipses that were analyzed for the “IRAC Data Challenge 2015.” Our results are consistent within 1σ with the ones reported in Wong et al. (2014) and with most of the results reported in Ingalls et al. (2016), which appeared on arXiv while this paper was under review. Based on many statistical tests discussed in Ingalls et al. (2016), the wavelet pixel-ICA method performs as well as or better than other state-of-art methods recently developed by other teams to analyze Spitzer/IRAC data, and, in particular, it appears to be the most repeatable and the most reliable, while reaching the photon noise limit, at least for the particular data set analyzed. Another strength of the ICA approach is its highest objectivity, as it does not use prior information about the instrument systematics, making it a promising method to analyze data from other observatories. The self-consistency of individual measurements of eclipse depth and phase curve slope over a span of more than three years proves the stability of Warm Spitzer/IRAC photometry within the error bars, at the level of 1 part in 10{sup 4} in stellar flux.

79 ASTRONOMY AND ASTROPHYSICS↗

A Methodology for Reliability Assessments of Arbitrary Satellite Constellations

The commercial success of small satellite development and multi-satellite missions has led to constellation missions being proposed in every sector of the market. This paradigm shift has the potential to enable more capable and cost-effective space science missions. However, these novel approaches to space missions have outstripped existing policy and analysis methods for assessing the reliability of multi-satellite missions. Mission designers and decisionmakers need new methods and standards for modeling how the reliability of constituent spacecraft elements affect the aggregate reliability of constellations across a wide range of concepts and application-specific requirements. The Space Mission Analysis Branch at NASA’s Langley Research Center has developed a methodology for simulating the on-orbit reliability of arbitrary spacecraft constellations. In this paper, the authors describe the methodology and provides examples of how it can be used to evaluate specific constellation designs. To demonstrate the flexibility of the approach, several different constellation configurations are considered, including both homogenous and heterogenous designs. Next, the authors demonstrate the ability to perform broad parameter sweeps to develop greater insight into the intrinsic reliability trends associated with constellation concepts. Finally, the authors provide tables and novel data graphics which enable decisionmakers to quickly discern the relationships between constellation sizes, topologies, replenishment strategies, and overall constellation reliability.

satellite↗

Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components

Introduction Bioelectrical impedance analysis (BIA) systems are gaining popularity for use in research and fitness assessments as the technology improves and becomes more affordable and easier to use. Multifrequency BIA (MF-BIA) may improve accuracy and precision using octopolar contacts for segmental analyses. Purpose Evaluate reliability, biological variability, and accuracy of component measures (total body water, mass, and composition) of commercially available MF-BIA system (InBody 770, Cerritos, California, USA). Methods Fourteen healthy military-age adults were assessed by MF-BIA in duplicate on five laboratory visits across 3 weeks (10 measures each). Participants were evaluated at the same time of day after refraining from strenuous exercise (> 48 h), alcohol consumption (> 24 h), and caffeine, nicotine, and food (> 10 h). Systematic error (test–retest reliability) and biological variability (day-to-day reliability) were summarized by intraclass correlation coefficient (ICC) values determined for body mass (fat, fat-free, total) and body water (extracellular, intracellular, total). Body composition measurements derived from BIA on the second visit were also tested for accuracy compared to dual-energy x-ray absorptiometry (DXA). Results Test–retest reliability was very high for all measurements of whole-body water and mass (ICC ≥ 0.999) and high for regional body water and mass (ICC 0.973–1.000). Biological variability was observable with very minor differences between tests (same day) for total and regional body water (0.0–0.2 L) and total and regional body mass measurements (0.0–0.2 kg); while between day differences were slightly higher (0.0–0.5 L and 0.1–0.7 kg). Compared to DXA, the MF-BIA whole-body measures showed an offset in %BF (Bias −4.0 ± 2.8%; Standard error of the estimate (SEE), 2.6%), an overprediction for total body fat-free mass (Bias 2.8 ± 2.1 kg; SEE 2.2 kg) and an underprediction of total body fat mass (Bias −2.9 ± 2.0 kg; SEE 1.9 kg). Conclusion Under controlled conditions with fit and healthy men and women, this MF-BIA system has high methodological reliability and demonstrates stable day-to-day measurements of major body composition components. Previously reported ~3% body fat offset compared to criterion methods was again confirmed. Precision of the InBody 770 shows consistency and supports further testing of this specific device as a new military standards method and suitability across a wider range of %BF.

Nutrition & Dietetics↗

Topology property analysis and application of stable time-delay regions for linear multiple time-delay systems

This study examines the relationship between the topology of stable time-delay regions and the stability analysis of an linear multiple time delay system. To analyze the topology of stable time-delay regions, we construct a function with a value equal to zero for the time-delay points on the boundaries of stable time-delay regions. The function is continuous and differentiable in the whole defining field with a global minimum of zero so that we can locate the boundaries by minimizing the value of the function. Based on the topology analysis, we proposed a performance validation approach for controllers that are designed to stabilize the system using feedback signals with time delays. The method based on the topology analysis is simple and reliable so that can deal with a linear time-invariant system with high order and multiple time delays (more than 3). The example case study shows that the above method is reliable and enables ultra-low latency coordination and control for the future power grid with ubiquitous power electronics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-cell, triple pane, vacuum insulated glazing

A novel Triple Pane Vacuum Insulated Glazing (TPVIG) architecture consisting of three panes of glass separated by two offset grids is described. The grids are made of frit-coated fibers fused with the glass panes in a vacuum to create many independent hermetic cells. Unlike traditional VIGs, which are separated by support pillars, these cells significantly increase the redundancy in sealing, and the additional bonds formed by the grid lines reduce the stresses on the edge bonds thereby increasing VIG reliability. A numerical thermal analysis was conducted to determine the thermal performance of the VIG and suggested U-values below 0.5 W/m 2 -K (greater than R=11.4 hr-ft 2 -°F/Btu) can be obtained. A prototype of the VIG unit consisting of three glass panes (5.7 mm, 1.1 mm and 5.7 mm thick with low-e coating on two surfaces) was fabricated and tested for thermal performance using the hot box method. The experimental center of glass U-value for the VIG was found to be 0.42 W/m 2 K (R=13.2 hr-ft 2 -°F/Btu). Furthermore, this U-value is about four times lower than a typical Argon filled double pane window.

14 SOLAR ENERGY↗

Bringing Molecular Dynamics Simulation Data into View

Molecular Dynamics (MD) simulations monitor time-resolved motions of macromolecules. While visualization of MD trajectories allows an instant and intuitive understanding of dynamics and function, so far mainly static representations are provided in published literature. Recent advances in browser technology may allow for the sharing of trajectories through interactive visualization on the web. We believe that by providing intuitive and interactive visualization along with related protocols and analysis data promotes understanding, reliability, and re-usability of MD simulations. Existing barriers for sharing MD simulations are discussed and emerging solutions are highlighted. We predict that interactive visualization of MD trajectories will quickly be adopted by researchers, research consortiums, journals, and funding agencies to gather and distribute results from MD simulations via the web.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mapping Composition Evolution through Synthesis, Purification, and Depolymerization of Random Heteropolymers

Random heteropolymers (RHPs) consisting of three or more comonomers have been routinely used to synthesize functional materials. While increasing the monomer variety diversifies the side-chain chemistry, this substantially expands the sequence space and leads to ensemble-level sequence heterogeneity. Most studies have relied on monomer composition and simulated sequences to design RHPs, but the questions remain unanswered regarding heterogeneities within each RHP ensemble and how closely these simulated sequences reflect the experimental outcomes. Here, we quantitatively mapped out the evolution of monomer compositions in four-monomer-based RHPs throughout a design-synthesis-purification-depolymerization process. By adopting a Jaacks method, we first determined 12 reactivity ratios directly from quaternary methacrylate RAFT copolymerization experiments to account for the influences of competitive monomer addition and the reversible activation/deactivation equilibria. The reliability of in silico analysis was affirmed by a quantitative agreement (<4% difference) between the simulated RHP compositions and the experimental results. Furthermore, we mapped out the conformation distribution within each ensemble in different solvents as a function of monomer chemistry, composition, and segmental characteristics via high-throughput computation based on self-consistent field theory (SCFT). These comprehensive studies confirmed monomer composition as a viable design parameter to engineer RHP-based functional materials as long as the reactivity ratios are accurately determined and the livingness of RHP synthesis is ensured.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Source Levels of In‐Cloud Air in Shallow Cumulus: Consistency Between Paluch Diagram and Lagrangian Particle Tracking

Abstract The Paluch diagram is a widely used tool for interpreting aircraft measurements of shallow cumulus clouds. A prior study conducted by Heus et al. (2008,https://doi.org/10.1175/2008jas2572.1) concluded that the source levels of in‐cloud air inferred from the Paluch diagram exhibit biases, sometimes of several hundred meters, in comparison to those derived from Lagrangian particle tracking. In this short study we revisit this comparison. The results indicate that the upper source levels of in‐cloud air determined from the Lagrangian Particle Tracking and the Paluch diagram are consistent, and the choice of statistical methods is crucial. The significance of this research lies in confirming the reliability of the Paluch analysis, enabling its confident application to aircraft data.

Meteorology & Atmospheric Sciences↗

ToF-SIMS evaluation of PEG-related mass peaks and applications in PEG detection in cosmetic products

Polyethylene glycols (PEGs) are used in industrial, medical, health care, and personal care applications. The cycling and disposal of synthetic polymers like PEGs pose significant environmental concerns. Detecting and monitoring PEGs in the real world calls for immediate attention. This study unveils the efficacy of time-of-flight secondary ion mass spectrometry (ToF-SIMS) as a reliable approach for precise analysis and identification of reference PEGs and PEGs used in cosmetic products. By comparing SIMS spectra, we show remarkable sensitivity in pinpointing distinctive ion peaks inherent to various PEG compounds. Moreover, the employment of principal component analysis effectively discriminates compositions among different samples. Notably, the application of SIMS two-dimensional image analysis visually portrays the spatial distribution of various PEGs as reference materials. The same is observed in authentic cosmetic products. The application of ToF-SIMS underscores its potential in distinguishing PEGs within intricate environmental context. ToF-SIMS provides an effective solution to studying emerging environmental challenges, offering straightforward sample preparation and superior detection of synthetic organics in mass spectral analysis. These features show that SIMS can serve as a promising alternative for evaluation and assessment of PEGs in terms of the source, emission, and transport of anthropogenic organics.

36 MATERIALS SCIENCE↗

Detection and characterization of nanoparticles in suspension at low concentrations using the X-ray total scattering pair distribution function technique

Difference atomic pair distribution function methods have been applied to detect and characterize nanoparticles suspended in a solvent at very dilute concentrations. We specifically consider nanoparticles of a pharmaceutical compound in aqueous solution using X-ray PDF methods, a challenging case due to the low atomic number of the nanoparticle species. In this work, the nanoparticles were unambiguously detected at the level of 0.25 wt%. Even at these low concentrations the signals were highly reproducible, allowing for reliable detection and quantitative analysis of the nanoparticle structure.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Implementation of IAEA /1/INT/054 Project in Nuclear Analytical Techniques Group of Argentina: Current State

This paper presents the implementation of the training received through the IAEA Project 'Preparation of Reference Materials and Organization of Proficiency Tests Rounds' in the Nuclear Analytical (NAT) Group of CNEA. Special emphasis is done on those activities related to the first Proficiency Test being carried out by the NAT Group.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Improved Boosting to Amplify Signal with Isobaric Labeling (iBASIL) Strategy for Precise Quantitative Single-cell Proteomics

Mass spectrometry (MS)-based proteomics has great potential for overcoming the limitations of antibody-based immunoassays for antibody-independent, comprehensive, and quantitative proteomic analysis of single cells. Indeed, recent advances in nanoscale sample preparation have enabled effective processing of single cells. In particular, the concept of using boosting/carrier channels in isobaric labeling to increase the sensitivity in MS detection has also been increasingly used for quantitative proteomic analysis of small-sized samples including single cells. However, the full potential of such boosting/carrier approaches has not been significantly explored, nor has the resulting quantitation quality been carefully evaluated. Herein, we have further evaluated and optimized our recent boosting to amplify signal with isobaric labeling (BASIL) approach, originally developed for quantifying phosphorylation in small number of cells, for highly effective analysis of proteins in single cells. This improved BASIL (iBASIL) approach enables reliable quantitative single-cell proteomics analysis with greater proteome coverage by carefully controlling the boosting-to-sample ratio (e.g. in general <100×) and optimizing MS automatic gain control (AGC) and ion injection time settings in MS/MS analysis (e.g. 5E5 and 300 ms, respectively, which is significantly higher than that used in typical bulk analysis). By coupling with a nanodroplet-based single cell preparation (nanoPOTS) platform, iBASIL enabled identification of ~2500 proteins and precise quantification of ~1500 proteins in the analysis of 104 FACS-isolated single cells, with the resulting protein profiles robustly clustering the cells from three different acute myeloid leukemia cell lines. This study highlights the importance of carefully evaluating and optimizing the boosting ratios and MS data acquisition conditions for achieving robust, comprehensive proteomic analysis of single cells.

59 BASIC BIOLOGICAL SCIENCES↗

Deep neural network uncertainty quantification for LArTPC reconstruction

We evaluate uncertainty quantification (UQ) methods for deep learning applied to liquid argon time projection chamber (LArTPC) physics analysis tasks. As deep learning applications enter widespread usage among physics data analysis, neural networks with reliable estimates of prediction uncertainty and robust performance against overconfidence and out-of-distribution (OOD) samples are critical for their full deployment in analyzing experimental data. While numerous UQ methods have been tested on simple datasets, performance evaluations for more complex tasks and datasets are scarce. Here we assess the application of selected deep learning UQ methods on the task of particle classification using the PiLArNet monte carlo 3D LArTPC point cloud dataset. We observe that UQ methods not only allow for better rejection of prediction mistakes and OOD detection, but also generally achieve higher overall accuracy across different task settings. We assess the precision of uncertainty quantification using different evaluation metrics, such as distributional separation of prediction entropy across correctly and incorrectly identified samples, receiver operating characteristic curves (ROCs), and expected calibration error from observed empirical accuracy. We conclude that ensembling methods can obtain well calibrated classification probabilities and generally perform better than other existing methods in deep learning UQ literature.

47 OTHER INSTRUMENTATION↗

Experimental study of the isomeric state in 16 N using the 16 N$^{g,m}$($\textit{d}$, 3 He) reaction

Here, the isomeric state of 16 N was studied using the 16 N$^{g,m}$($\textit{d}$, 3 He) proton-removal reactions at 11.8 MeV/u in inverse kinematics. The 16 N beam, of which 24% was in the isomeric state, was produced using the Argonne Tandem-Linac Accelerator System (ATLAS) in-flight system and delivered to the Helical Orbit Spectrometer (HELIOS), which was used to analyze the 3 He ions from the ($\textit{d}$, 3 He) reactions. The simultaneous measurement of reactions on both the ground state and the isomeric states, reduced the systematic uncertainties from the experiment and in the analysis. A direct and reliable extraction of the relative spectroscopic factors was made based on a distorted-wave Born approximation approach. The experimental results suggest that the isomeric state of 16N is an excited neutron-halo state. The results can be understood through calculations using a Woods-Saxon potential model, which captures the effects of weak binding.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗