Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Space tug thermal control follow-on

The Space Tug Thermal Control Follow-On program was conducted to further explore some of the thermal control concepts proposed for use in space tug in a breadboard test program. The objectives were to demonstrate the thermal control capabilities of a louver/battery configuration and a thermal conditioning panel/heat pipe radiator configuration. An additional objective was added to model the header pipe and radiator of the second test and correlate the analysis with the test results. These three objectives were achieved and are discussed within this report.

Ward, T. L.↗

Cloud Radiative Forcing at the ARM Climate Research Facility: Technique, Validation, and Comparison to Satellite-derived Diagnostic Quantities - Part 1

It has been hypothesized that continuous ground-based remote sensing measurements from active and passive remote sensors combined with regular soundings of the atmospheric thermodynamic structure can be combined to describe the effects of clouds on the clear sky radiation fluxes. We critically test that hypothesis in this paper and a companion paper (Part II). Using data collected at the Southern Great Plains (SGP) Atmospheric Radiation Measurement (ARM) site sponsored by the U.S. Department of Energy, we explore an analysis methodology that results in the characterization of the physical state of the atmospheric profile at time resolutions of five minutes and vertical resolutions of 90 m. The description includes thermodynamics and water vapor profile information derived by merging radiosonde soundings with ground-based data, and continues through specification of the cloud layer occurrence and microphysical and radiative properties derived from retrieval algorithms and parameterizations. The description of the atmospheric physical state includes a calculation of the infrared and clear and cloudy sky solar flux profiles. Validation of the methodology is provided by comparing the calculated fluxes with top of atmosphere (TOA) and surface flux measurements and by comparing the total column optical depths to independently derived estimates. We find over a 1-year period of comparison in overcast uniform skies, that the calculations are strongly correlated to measurements with biases in the flux quantities at the surface and TOA of less than 10% and median fractional errors ranging from 20% to as low as 2%. In the optical depth comparison for uniform overcast skies during the year 2000 where the optical depth varies over 3 orders of magnitude we find a mean positive bias of 46% with a median bias of less than 10% and a 0.89 correlation coefficient. The slope of the linear regression line for the optical depth comparison is 0.86 with a normal deviation of 20% about this line. In addition to a case study where we examine the cloud radiative effects at the TOA, surface and atmosphere by a middle latitude synoptic-scale cyclone, we examine the cloud top pressure and optical depth retrievals of ISCCP and LBTM over a period of 1 year. Using overcast period from the year 2000, we find that the satellite algorithms tend to bias cloud tops into the middle troposphere and underestimate optical depth in high optical depth events (greater than 100) by as much as a factor of 2.

Mace, Gerald G.↗

TPS: From Arc-Jet to Flight

This slide presentation reviews the testing of thermal protection system materials. All space vehicles that reenter Earth's atmosphere from either LEO or from Lunar/Mars missions require thermal protection system (TPS) materials. These TPS materials requires ground test facilities that simulate the aerothermodynamic environments experienced by reentry. The existing arc-jet facility requires expansion to combine convective and radiation heating and to test the capability to protect with the CO2 atmosphere that will be encountered for Martian entry.

Buslog, Stanley A.↗

Hot Hydrogen Testing of Tungsten-Uranium Dioxide (W-UO2) CERMET Fuel Materials for Nuclear Thermal Propulsion

CERMET fuel materials are being developed at the NASA Marshall Space Flight Center for a Nuclear Cryogenic Propulsion Stage. Recent work has resulted in the development and demonstration of a Compact Fuel Element Environmental Test (CFEET) System that is capable of subjecting depleted uranium fuel material samples to hot hydrogen. A critical obstacle to the development of an NCPS engine is the high-cost and safety concerns associated with developmental testing in nuclear environments. The purpose of this testing capability is to enable low-cost screening of candidate materials, fabrication processes, and further validation of concepts. The CERMET samples consist of depleted uranium dioxide (UO2) fuel particles in a tungsten metal matrix, which has been demonstrated on previous programs to provide improved performance and retention of fission products1. Numerous past programs have utilized hot hydrogen furnace testing to develop and evaluate fuel materials. The testing provides a reasonable simulation of temperature and thermal stress effects in a flowing hydrogen environment. Though no information is gained about radiation damage, the furnace testing is extremely valuable for development and verification of fuel element materials and processes. The current work includes testing of subscale W-UO2 slugs to evaluate fuel loss and stability. The materials are then fabricated into samples with seven cooling channels to test a more representative section of a fuel element. Several iterations of testing are being performed to evaluate fuel mass loss impacts from density, microstructure, fuel particle size and shape, chemistry, claddings, particle coatings, and stabilizers. The fuel materials and forms being evaluated on this effort have all been demonstrated to control fuel migration and loss. The objective is to verify performance improvements of the various materials and process options prior to expensive full scale fabrication and testing. Post test analysis will include weight percent fuel loss, microscopy, dimensional tolerance, and fuel stability.

Hickman, Robert↗

Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module

This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with “generic” component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A gamma-ray testing technique for spacecraft

The simulated cosmic radiation effect on a spacecraft structure is evaluated by gamma ray testing in relation to structural thickness. A drawing of the test set-up is provided and measurement errors are discussed.

Gribov, B. S.↗

Performance of Goddard Earth Observing System GCM Column Radiation Models under Heterogeneous Cloud Conditions

We test the performance of the shortwave (SW) and longwave (LW) Column Radiation Models (CORAMs) of Chou and collaborators with heterogeneous cloud fields from a global single-day dataset produced by NCAR's Community Atmospheric Model with a 2-D CRM installed in each gridbox. The original SW version of the CORAM performs quite well compared to reference Independent Column Approximation (ICA) calculations for boundary fluxes, largely due to the success of a combined overlap and cloud scaling parameterization scheme. The absolute magnitude of errors relative to ICA are even smaller for the LW CORAM which applies similar overlap. The vertical distribution of heating and cooling within the atmosphere is also simulated quite well with daily-averaged zonal errors always below 0.3 K/d for SW heating rates and 0.6 K/d for LW cooling rates. The SW CORAM's performance improves by introducing a scheme that accounts for cloud inhomogeneity. These results suggest that previous studies demonstrating the inaccuracy of plane-parallel models may have unfairly focused on worst scenario cases, and that current radiative transfer algorithms of General Circulation Models (GCMs) may be more capable than previously thought in estimating realistic spatial and temporal averages of radiative fluxes, as long as they are provided with correct mean cloud profiles. However, even if the errors of the particular CORAMs are small, they seem to be systematic, and the impact of the biases can be fully assessed only with GCM climate simulations.

Oreopoulos, L.↗

National Emission Standards for Hazardous Air Pollutants – Radionuclide Emissions (CY 2019)

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) operates the Nevada National Security Site (NNSS) and the North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NNSS activities has been monitored since the initiation of atmospheric testing. After 1962, testing was limited to underground detonations, which greatly reduced radiation exposure to the public. Since the end of nuclear testing in 1992, radiation monitoring has focused on detecting airborne radionuclides from historically contaminated soils because this source dominates the potential offsite dose. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of legacy-related tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas.

99 GENERAL AND MISCELLANEOUS↗

National Emission Standards for Hazardous Air Pollutants – Radionuclide Emissions Calendar Year 2020

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) operates the Nevada National Security Site (NNSS) and the North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons. Radionuclides in air from NNSS activities have been monitored since the initiation of atmospheric testing. After 1962, testing was limited to underground detonations, which greatly reduced radiation exposure to the public. Since the end of nuclear testing in 1992, radiation monitoring has focused on detecting airborne radionuclides from historically contaminated soils because this sources dominates the potential offsite dose. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of legacy-related tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas. To protect the public from harmful levels of manmade radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP), specifically the National Emission Standards for Emissions of Radionuclides Other Than Radon From Department of Energy Facilities (40 CFR 61, Subpart H, 2020) limits the release of radioactivity from a DOE facility to that which would cause 10 millirem per year (mrem/y) effective dose equivalent (EDE) to any member of the public. This limit does not include radiation unrelated to NNSS activities. Unrelated doses could come from naturally occurring radioactive elements, from sources such as medically or commercially used radionuclides, or from sources outside of the United States, such as Japan’s Fukushima nuclear power plant, which was damaged in 2011. NNSA/NFO demonstrates compliance with the NESHAP limit by reporting environmental measurements of radionuclide air concentrations at critical receptor locations on the NNSS. This alternative was proposed and formerly submitted to the U.S. Environmental Protection Agency (EPA) in 2001 (EPA 2001a) and has been the method used to demonstrate compliance with the 40 CFR 61.92 dose standard since 2005. Six locations on the NNSS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are closer to radionuclide releases than where the public resides so they act as protective substitutes for public receptor locations. Compliance is demonstrated if the measured annual average concentration is less than the NESHAP Concentration Level (CL) for Environmental Compliance listed in Table 2 of 40 CFR 61, Appendix E. For multiple radionuclides, compliance is demonstrated when the sum of the fractions (determined by dividing each radionuclide’s concentration by its CL and then adding the fractions together) is less than 1.0. The EPAapproved air transport model, called the Clean Air Package 1988 (CAP88-PC) is also used to calculate the effective dose equivalent to the maximally exposed individual from NNSS air emissions. CAP88-PC was also used to calculate the population dose, or the collective EDE (expressed as person-rem [roentgen equivalent man] per year [person-rem/y]) for all individuals combined who reside within 80 kilometers (km) of NNSS emission sources. In 2020, the potential dose from radiological emissions to air from both current and past NNSS activities was well below the 10 mrem/y dose limit. This is demonstrated by both the air sampling data collected at critical receptor air monitoring stations and CAP88-PC modeling. The average concentrations of radioactivity at air critical receptor stations ranged from 0.2% to a maximum of 4.2% of the allowed NESHAP limit. CAP88-PC modeling of all 2020 NNSS radionuclide emissions showed the maximally exposed individual to be in Amargosa Valley and this individual received a potential dose of 0.063 mrem/y. The collective dose was calculated to be 0.29 person-rem/year for the 521,300 people who lived within 80 km of NNSS emission sources.

99 GENERAL AND MISCELLANEOUS↗

RADIATION EFFECTS ON EPOXY/CARBON FIBER COMPOSITE

The Department of Energy Savannah River Site vitrifies nuclear waste incident to defense programs through its Defense Waste Processing Facility (DWPF). The piping in the DWPF seal pot jumper configuration must withstand the stresses during an unlikely but potential deflagration event, and maintain its safety function for a 20-year service life. Carbon fiber-reinforced epoxy composites (CFR) were proposed for protection and reinforcement of piping during such an event. The proposed CFR materials have been ASME-approved (Section XI, Code Case N-589-1) for post-construction maintenance and is DOT-compliant per 49CFR 192 and 195. The proposed carbon fiber/epoxy composite reinforcement system was originally developed for pipeline rehabilitation and post-construction maintenance in petrochemical, refineries, DOT applications and other industries. The effects of ionizing radiation on polymers and organic materials have been studied for many years. The majority of available data are based on traditional exposures to gamma irradiation at high dose rates ({approx}10,000 Gy/hr) allowing high total dose within reasonable test periods and general comparison of different materials exposed at such conditions. However, studies in recent years have shown that degradation of many polymers are sensitive to dose rate, with more severe degradation often observed at similar or even lower total doses when exposed to lower dose rates. This behavior has been primarily attributed to diffusion-limited oxidation which is minimized during very high dose rate exposures. Most test standards for accelerated aging and nuclear qualification of components acknowledge these limitations. The results of testing to determine the radiation resistance and microstructural effects of gamma irradiation exposure on a bisphenol-A based epoxy matrix composite reinforced with carbon fibers are presented. This work provides a foundation for a more extensive evaluation of dose rate effects on advanced epoxy reinforced composites.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The use of solar simulation systems for producing artificial global radiation for the purpose of determining the heat load of rooms

Certain climatic tests which require solar and sky radiation were carried out in the laboratory by using simulated global radiation. The advantages of such a method of measurement and the possibilities and limitations resulting from the simulation of global radiation are described. Experiments concerning the thermal load in rooms were conducted in order to test the procedure. In particular, the heat gain through a window with sunshade is discussed, a venetian blind between the panes of a double-glazed window being used in most cases.

Kalt, A. C.↗

TU-F-CAMPUS-T-02: Vernier Picket Fence Test: A Non-Imaging Method to Localize the Radiation Isocenter with Submillimeter Accuracy

Purpose: The purpose of this study is to propose a new non-imaging method to localize the radiation isocenter with submillimeter accuracy. Methods: The Vernier picket fence (VPF) is a multileaf collimator (MLC) picket fence sequence in which the fence spacing is 1/N smaller than the detector spacing of the QA phantom, where N is the magnification factor, typically set to 10 or 20. Similar to reading a Vernier caliper, the user can easily achieve the resolution of 1/N of the detector spacing by visually inspecting the maximum signal. To achieve higher accuracy, a Gaussian model was used to interpolate the peak position, which can fall between adjacent detectors. In two separate tests, precise MLC offsets and imprecise couch offsets were applied to a 2D detector array (MapCheck, Sun Nuclear Corp., Melbourne, Florida) to introduce setup errors. Two vertical VPF fields were delivered with collimator angles at 0° and 90° to detect the lateral and longitudinal setup errors, respectively. For a rotational QA phantom, an additional lateral VPF field is needed to detect the vertical setup error for three-dimensional capabilities. Results: With N set to 20 and a detector spacing of 5 mm for MapCheck, the resolution of the VPF’s visual analysis is 0.25 mm. With the Gaussian interpretation, the VPF can achieve an accuracy of 0.02 mm, as shown by the MLC offset test. The couch offset test measured the couch hysteresis and demonstrated that the setup error detected by the VPF differed from the ExacTrac™ (Brainlab AG, Feldkirchen, Germany) optical tracking by 0.055 mm in the lateral direction and 0.041 mm in the longitudinal direction on average. The VPF was also shown to be feasible in the vertical direction as well. Conclusion: This study verified the VPF as a non-imaging method to localize the radiation isocenter with submillimeter accuracy. Funding is in part by the Portland Chapter of the Achievement Rewards for College Scientists. The content is solely the responsibility of the authors, and does not necessarily represent the official views of the sponsors. The authors declare no conflict of interest.

60 APPLIED LIFE SCIENCES↗

Impact of specimen preparation method on photovoltaic backsheet degradation during accelerated aging test

In this study, we highlight some important factors in the specimen preparation methods for evaluating photovoltaic backsheet properties after accelerated aging. Two different sequences are considered: Method (I) cut-then-age: cut into 1-cm wide strips and then expose to stress, and Method (II) age-then-cut: expose a larger sheet to stress and then cut into 1-cm widths for mechanical property measurements. We also compare the effect of three cutting methods, (a) tensile specimen punch, (b) paper cutter, and (c) fresh razor blade. Several commercial backsheets were evaluated, with stress exposures including (a) pressure cooker test (PCT), (b) dry ultraviolet (UV) radiation exposure, and (c) UV combined damp heat tests. Fourier transform infrared spectrometer (FTIR) and intrinsic viscosity (IV) were used to analyze the materials on unstressed materials and samples exposed to PCT. The results show that both the cutting method and the time of cutting have an impact on the backsheet mechanical properties. Additionally, under UV exposure, Method II, age-then-cut, generally resulted in a higher average value, with more variation than Method I; however, if the side strips from Method II were excluded, the variation dropped to the same level. This is because the specimens at the sides of the sheet get additional damage from UV light from the exposed sides of the sample. In contrast to UV exposure, PCT specimens prepared by Method II result in lower average values and higher variability. This is attributed to embrittlement through the bulk of the sample where the cutting of embrittled specimens appears to result in more edge defects which can then initiate a break at smaller strains. The data suggest that for UV exposures, the specimens should be cut after aging and the exposed side specimens discarded, and that for PCT exposures, the specimens should be cut before the exposure.

14 SOLAR ENERGY↗

Detecting Radiation-Induced Injury Using Rapid 3D Variogram Analysis of CT Images of Rat Lungs

A new heterogeneity analysis approach to discern radiation-induced lung damage was tested on CT images of irradiated rats. The method, combining octree decomposition with variogram analysis, demonstrated a significant correlation with radiation exposure levels, whereas conventional measurements and pulmonary function tests did not. The results suggest the new approach may be highly sensitive for assessing even subtle radiation-induced changes

Jacob, Rick E.↗

A simplified CFD model for spectral radiative heat transfer in high-pressure hydrocarbon–air combustion systems

Detailed radiation modeling in piston engines has received relatively little attention to date. Recently, it is being revisited in light of current trends towards higher operating pressures and higher levels of exhaust-gas recirculation (EGR), both of which enhance molecular gas radiation. Advanced high-efficiency engines also are expected to function closer to the limits of stable operation, where even small perturbations to the energy balance can have a large influence on system behavior. Detailed radiation modeling using sophisticated tools like photon Monte Carlo/line-by-line (PMC/LBL) is computationally expensive. Here, guided by results from PMC/LBL, a simplified stepwise-gray spectral model in combination with a first-order spherical harmonics (P1 method) radiative transfer equation (RTE) solver is proposed and tested for engine-relevant conditions. Radiative emission, reabsorption and radiation reaching the walls are computed for a heavy-duty compression-ignition engine at part-load and full-load operating conditions with different levels of EGR and soot. The results are compared with those from PMC/LBL, P1/FSK (P1 with a full-spectrum k-distribution spectral model) and P1/Gray radiation models to assess the proposed model’s accuracy and computational cost. The results show that the proposed P1/StepwiseGray model can calculate reabsorption locally and globally with less than 10% error (with respect to PMC/LBL) at a small fraction of the computational cost of PMC/LBL (a factor of 30) and P1/FSK (a factor of 15). In contrast, error in computed reabsorption by the P1/Gray model is as high as 60%. Finally, it is expected that the simplified model should be broadly applicable to high-pressure hydrocarbon–air combustion systems, with or without soot.

42 ENGINEERING↗

Laser-driven cylindrical compression of targets for fast electron transport study in warm and dense plasmas

Fast ignition requires a precise knowledge of fast electron propagation in a dense hydrogen plasma. In this context, a dedicated HiPER (High Power laser Energy Research) experiment was performed on the VULCAN laser facility where the propagation of relativistic electron beams through cylindrically compressed plastic targets was studied. In this paper, we characterize the plasma parameters such as temperature and density during the compression of cylindrical polyimide shells filled with CH foams at three different initial densities. X-ray and proton radiography were used to measure the cylinder radius at different stages of the compression. By comparing both diagnostics results with 2D hydrodynamic simulations, we could infer densities from 2 to 11 g/cm{sup 3} and temperatures from 30 to 120 eV at maximum compression at the center of targets. According to the initial foam density, kinetic, coupled (sometimes degenerated) plasmas were obtained. The temporal and spatial evolution of the resulting areal densities and electrical conductivities allow for testing electron transport in a wide range of configurations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synchrotron-based coherent scatter x-ray projection imaging using an array of monoenergetic pencil beams

Traditional projection x-ray imaging utilizes only the information from the primary photons. Low-angle coherent scatter images can be acquired simultaneous to the primary images and provide additional information. In medical applications scatter imaging can improve x-ray contrast or reduce dose using information that is currently discarded in radiological images to augment the transmitted radiation information. Other applications include non-destructive testing and security. A system at the Canadian Light Source synchrotron was configured which utilizes multiple pencil beams (up to five) to create both primary and coherent scatter projection images, simultaneously. The sample was scanned through the beams using an automated step-and-shoot setup. Pixels were acquired in a hexagonal lattice to maximize packing efficiency. The typical pitch was between 1.0 and 1.6 mm. A Maximum Likelihood-Expectation Maximization-based iterative method was used to disentangle the overlapping information from the flat panel digital x-ray detector. The pixel value of the coherent scatter image was generated by integrating the radial profile (scatter intensity versus scattering angle) over an angular range. Different angular ranges maximize the contrast between different materials of interest. A five-beam primary and scatter image set (which had a pixel beam time of 990 ms and total scan time of 56 min) of a porcine phantom is included. For comparison a single-beam coherent scatter image of the same phantom is included. The muscle-fat contrast was 0.10 {+-} 0.01 and 1.16 {+-} 0.03 for the five-beam primary and scatter images, respectively. The air kerma was measured free in air using aluminum oxide optically stimulated luminescent dosimeters. The total area-averaged air kerma for the scan was measured to be 7.2 {+-} 0.4 cGy although due to difficulties in small-beam dosimetry this number could be inaccurate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗