Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

A position-aware linear solid constitutive model for peridynamics

A position-aware linear solid (PALS) peridynamic constitutive model is proposed for isotropic elastic solids. The PALS model addresses problems that arise, in ordinary peridynamic material models such as the linear peridynamic solid (LPS), due to incomplete neighborhoods near the surface of a body. We improved model behavior in the vicinity of free surfaces through the application of two influence functions that correspond, respectively, to the volumetric and deviatoric parts of the deformation. Furthermore, the model is position-aware in that the influence functions vary over the body and reflect the proximity of each material point to free surfaces. Demonstration calculations on simple benchmark problems show a sharp reduction in error relative to the LPS model.

36 MATERIALS SCIENCE↗

Position-Sensitive Fast-Neutron Detector Development in Support of Fuel-Cycle R&D MPACT Campaign

In the present work, fast-neutron imaging detectors with centimeter position resolution are developed whose active volume is liquid scintillator EJ-309, allowing neutron-gamma discrimination via pulse shape. Furthermore, a production version sealed detector is constructed that allows arrangement in a close-packed array for imaging applications. The combination of position resolution, neutron-gamma discrimination, and ready assembly into an imaging array will enable sensitive diagnostic fast-neutron imaging of neutron sources of interest to fuel cycle applications.

Blackston, Matthew A.↗

Beam Position Detection Along the Collider Arms

A small position monitor is presented here which meets the Collider specifications for the detection of the beam position along the arms. This is a summary of the points worth noting regarding the operation of this detector.

Accelerators↗

High-Energy 3D Calorimeter based on position-sensitive virtual Frisch-grid CdZnTe detectors for use in Gamma-ray Astronomy

We present a concept for a calorimeter based on a novel approach of 3D position-sensitive virtual Frischgrid CZT detectors. This calorimeter aims to measure photons with energies from ~100 keV to 10 (goal 50) MeV. The expected energy resolution at 662 keV is ~1% FWHM, and the photon interaction positionmeasurement accuracy is ~1 mm in all 3 dimensions. Each CZT bar is a rectangular prism with typical cross-section of 6x6 mm 2 and length of 2-4 cm. The bars are arranged in modules of 4 x 4 bars, and the modules themselves can be assembled into a larger array. The 3D virtual voxel approach solves a long-standing problem with CZT detectors associated with material imperfections that limit the performance and usefulness of relatively thick detectors (i.e., > 1 cm). Also, it allows us to relax the requirements on the quality of the crystals, maintaining good energy resolution and significantly reducing the instrument cost. Such a calorimeter can be successfully used in space telescopes that use Compton scattering of γ rays, such as AMEGO, serving as part of its calorimeter and providing the position and energy measurement for Compton-scattered photons. Also, it could provide suitable energy resolution to allow for spectroscopic measurements of γ-ray lines from nuclear decays. Another viable option is to use this calorimeter as a focal plane to conduct spectroscopic measurements of cosmic γ-ray events. In combination with a coded-aperture mask, it potentially could provide mapping of the 511-keV radiation from the Galactic Center region.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A beam profile and position measurement system for the IPF target

Currently one determines the size and position of the proton beam at the IPF target using plastic films. These films are installed in a target carrier, lowered into position, exposed to the beam, raised back up to the hot cell, removed from the target carrier, and assessed via a video feed. About an hour is required for each cycle of measurement. Because of this high cost in terms of time the users usually settle for a beam that is good enough to meet their needs, but not as good as they would like. I propose here a diagnostic device that would enable a measurement of under two seconds. This would enable delivery of a better-quality beam in less time.

43 PARTICLE ACCELERATORS↗

A Double Sided LGAD-Based Detector Providing Timing, Position, and Track Angle Information

We describe a detector concept which combines small pixels enabled by 3D sensor-electronics integration with gain produced by a Low Gain Avalanche Diode (LGAD) layer. The detector is double-sided, with electrons collected by the cathode, which provides timing information, and an anode with small pixels to provide position and angle information. The cathode can be coarse grained, providing timing with fewer fast amplifiers to limit power consumption. The anode layer benefits from the gain of the LGAD, with larger signals that also limit the power needed. Position can be reconstructed by measuring the pattern of total charge deposited on the anode. Angle and depth of charge deposit can be measured by the shapes of the anode pulses. We describe a possible assembly technology based on 3D integration.

3D Integration↗

Position Papers for the ASCR Workshop on Cybersecurity and Privacy for Scientific Computing Ecosystems

At the request of the Department of Energy's (DOE) Office of Advanced Scientific Computing Research (ASCR), this program committee has been tasked with organizing a workshop to identify basic research needs in cybersecurity and privacy to better support DOE's science and energy mission. As part of the process, the program committee is soliciting community input in the form of position papers to help identify significant use cases, facility issues, and other barriers to enabling verifiably trustworthy computational science while preserving data confidentiality as appropriate for scientific workflows of interest to DOE. The program committee will review these position papers and based on the fit of their area of expertise and interest, selected contributors will have the opportunity to participate in the workshop currently planned as a virtual event November 3-5th, 2021. The thrust areas that will be explored by this workshop are the following: (1) Algorithms for secure, scalable, privacy-enhancing technologies and frameworks, including: Federated AI/ML, Differential privacy, Randomized algorithms, Adversarial modeling & simulation, Graph algorithms, and Formal methods; (2) Platforms to support the entire scientific-computing ecosystem, including edge computing for large-scale experiments, focusing on heterogeneous systems and distributed systems, including: Heterogeneous computing systems, Distributed computing systems, and Secure data architectures; and (3) Data workflows to allow agile use of data while preserving integrity and privacy, making the important properties verifiable either at runtime or post-computation, including: Integrity and provenance and Data management infrastructure. Topics that are out-of-scope for the workshop include discussing specific proposed solutions or areas that are clearly out of DOE's fundamental and applied-sciences mission scope, e.g., cryptography, enterprise security, and general-operations technology.

97 MATHEMATICS AND COMPUTING↗

Beam Position Monitor: Sensors, Calibration and Analysis [Slides]

A beam position monitor (BPM) provides information on electron beam current and position, essential to meeting the performance requirements for the Scorpius accelerator as laid down in FR1.1 –FR1.8 and FR2.2. The critical elements in employing BPM’s to meet those requirements are design of the sensor, design of calibration equipment for the sensor, and design of methods to record and process data.

43 PARTICLE ACCELERATORS↗

DARHT-II Beam Position Monitor B-Dot Owner’s Manual

Azimuthal arrays of magnetic and electric field detectors are used to measure the position of the centroid of the DARHT relativistic electron beams. These arrays consist of four detectors with 90-degree azimuthal separation. Differencing the opposing detectors and normalizing to the sum of all four gives the position of the beam, subject to negligibly small errors as discussed in Attachment A. This measurement yields the centroid of the current density, independent of the beam azimuthal asymmetry.

42 ENGINEERING↗

Calibration of the ProtoDUNE Horizontal-Drift position reconstruction using a laser system

Forthcoming in the next decade of neutrino physics advancements is the construction of the Deep Underground Neutrino Experiment (DUNE), a long baseline neutrino oscillation experiment which has the potential to answer fundamental questions such as why there is more matter than antimatter in the universe, and ultimately why we exist at all. A prototype of this experiment, ProtoDUNE, sits in a charged particle test beam at the European Organization for Nuclear Research (CERN) and uses Liquid Argon time projection chambers to image interactions of these particles. ProtoDUNE Single-Phase (ProtoDUNESP) had positively charged hadrons as well as positrons in its initial 2018 beam data run. Because ProtoDUNE is a surface-based time projection chamber, it experiences a constant influx of cosmic rays. These cosmic rays ionize the liquid argon within the detector, resulting in an accumulation of slow moving positive ions towards the cathode. This local charge distribution results in electric field non uniformities, which can have a significant effect on the accuracy of the event reconstruction. This paper outlines a monte carlo simulation study which adapts methodology from the MicroBooNE experiment, another neutrino oscillation experiment, to derive electric field correction maps which can correct for distortions of the electric field within the detector. These correction maps accurately estimate the electric field throughout the detector volume and correct for uncertainties in reconstructed event data enabling for physics discoveries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Position-Dependent Neutron Time-of-Flight Deviation at VULCAN Diffractometer

In neutron diffraction, it is critical to precisely measure the lattice spacing, as it is an indicator of a material’s physical characteristics, such as lattice strain, thermal expansion, and phase structures. In time-of-flight (TOF) measurements, the lattice spacing is determined by the recorded TOF from a well-calibrated instrument. However, changes in neutron time-of-flight are sensitive to many factors, such as the alignment of instrument optics, temperature, sample positions, sample dimensions, internal strains, and chemical or physical heterogeneities at the grain level. At VULCAN (SNS, ORNL), which is a high-flux engineering neutron diffractometer, we used a 1-mm-diameter diamond powder sample to scan for changes in TOF by measuring d-spacing values at different sample positions under several configurations. The 2D map of the TOF deviation or d-spacing deviation, in terms of lattice shift/lattice strain, is reported. The change in TOF is dependent on the scanned location in the beam as well as on detector locations. The results are informative for experimental planning, data interpretation, and future instrument design.

36 MATERIALS SCIENCE↗

Development of a Target Rod Rabbit Holder Facility in the Large Removable Beryllium Position

A new facility, the removable beryllium-target rod rabbit holder facility (RB*-TRRH), was designed and fielded in the large removable beryllium (RB*) position in the High Flux Isotope Reactor (HFIR). This facility supports three shortened target rod rabbit holders (sTRRHs), which allow for the irradiation of six axially stacked rabbit capsules per sTRRH. This will allow for the simultaneous irradiation of 18 rabbit capsules in the RB* position and will provide an alternative location for low-cost rabbit capsules to be irradiated in HFIR. The first capsules inserted into this facility are 18 perforated capsules that contain representative steel specimens of interest to the calandria of Canada deuterium uranium (CANDU) reactors as part of a lifetime extension program with Canadian Nuclear Laboratories (CNL).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Positioning and Geometric Distortion Correction on the SNS SiPM Anger Camera

Neutron Anger cameras are scintillator-based thermal neutron detectors that utilize pixelated photosensors to read out visible light signals and position neutrons accurately They are versatile detectors that can cover large areas for diffraction instruments and offer high efficiency and sub-millimeter spatial resolution. Photomultiplier Tube (PMT) based cameras are installed on three instruments at Spallation Neutron Source (SNS). The next generation camera uses Silicon Photomultipliers (SiPMs) instead of PMTs, which allows for a more compact design and higher spatial resolution. In this report, the Gaussian least-squares position fitting method is described in detail, as well as the method used to correct for geometric distortions across the face of the camera. Results from neutron camera tests before and after the distortion correction are shown and the spatial resolution is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies on two classes of positive electrode materials for lithium-ion batteries

The development of advanced lithium-ion batteries is key to the success of many technologies, and in particular, hybrid electric vehicles. In addition to finding materials with higher energy and power densities, improvements in other factors such as cost, toxicity, lifetime, and safety are also required. Lithium transition metal oxide and LiFePO 4 /C composite materials offer several distinct advantages in achieving many of these goals and are the focus of this report. Two series of layered lithium transition metal oxides, namely LiNi 1/3 Co 1/3-y M y Mn 1/3 O 2 (M=Al, Co, Fe, Ti) and LiNi 0.4 Co 0.2-y M y Mn 0.4 O 2 (M = Al, Co, Fe), have been synthesized. The effect of substitution on the crystal structure is related to shifts in transport properties and ultimately to the electrochemical performance. Partial aluminum substitution creates a high-rate positive electrode material capable of delivering twice the discharge capacity of unsubstituted materials. Iron substituted materials suffer from limited electrochemical performance and poor cycling stability due to the degradation of the layered structure. Titanium substitution creates a very high rate positive electrode material due to a decrease in the anti-site defect concentration. LiFePO 4 is a very promising electrode material but suffers from poor electronic and ionic conductivity. To overcome this, two new techniques have been developed to synthesize high performance LiFePO 4 /C composite materials. The use of graphitization catalysts in conjunction with pyromellitic acid leads to a highly graphitic carbon coating on the surface of LiFePO 4 particles. Under the proper conditions, the room temperature electronic conductivity can be improved by nearly five orders of magnitude over untreated materials. Using Raman spectroscopy, the improvement in conductivity and rate performance of such materials has been related to the underlying structure of the carbon films. The combustion synthesis of LiFePO 4 materials allows for the formation of nanoscale active material particles with high-quality carbon coatings in a quick and inexpensive fashion. The carbon coating is formed during the initial combustion process at temperatures that exceed the thermal stability limit of LiFePO 4 . The olivine structure is then formed after a brief calcination at lower temperatures in a controlled environment. The carbon coating produced in this manner has an improved graphitic character and results in superior electrochemical performance. The potential co-synthesis of conductive carbon entities, such as carbon nanotubes and fibers, is also briefly discussed.

25 ENERGY STORAGE↗

Completely Positive, Simple, and Possibly Highly Accurate Approximation of the Redfield Equation

Here we present a Lindblad master equation that approximates the Redfield equation, a well known master equation derived from first principles, without significantly compromising the range of applicability of the Redfield equation. Instead of full-scale coarse-graining, this approximation only truncates terms in the Redfield equation that average out over a time-scale typical of the quantum system. The first step in this approximation is to properly renormalize the system Hamiltonian, to symmetrize the gains and losses of the state due to the environmental coupling. In the second step, we swap out an arithmetic mean of the spectral density with a geometric one, in these gains and losses, thereby restoring complete positivity. This completely positive approximation, GAME (geometric-arithmetic master equation), is adaptable between its time-independent, time-dependent, and Floquet form. In the exactly solvable, three-level, Jaynes-Cummings model, we find that the error of the approximate state is almost an order of magnitude lower than that obtained by solving the coarse-grained stochastic master equation. As a test-bed, we use a ferromagnetic Heisenberg spin-chain with long-range dipole-dipole coupling between up to 25-spins, and study the differences between various master equations. We find that GAME has the highest accuracy per computational resource.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simultaneous Momentum and Position Measurement and the Instrumental Weyl-Heisenberg Group

The canonical commutation relation, [Q,P]=iℏ, stands at the foundation of quantum theory and the original Hilbert space. The interpretation of P and Q as observables has always relied on the analogies that exist between the unitary transformations of Hilbert space and the canonical (also known as contact) transformations of classical phase space. Now that the theory of quantum measurement is essentially complete (this took a while), it is possible to revisit the canonical commutation relation in a way that sets the foundation of quantum theory not on unitary transformations but on positive transformations. This paper shows how the concept of simultaneous measurement leads to a fundamental differential geometric problem whose solution shows us the following. The simultaneous P and Q measurement (SPQM) defines a universal measuring instrument, which takes the shape of a seven-dimensional manifold, a universal covering group we call the instrumental Weyl-Heisenberg (IWH) group. The group IWH connects the identity to classical phase space in unexpected ways that are significant enough that the positive-operator-valued measure (POVM) offers a complete alternative to energy quantization. Five of the dimensions define processes that can be easily recognized and understood. The other two dimensions, the normalization and phase in the center of the IWH group, are less familiar. The normalization, in particular, requires special handling in order to describe and understand the SPQM instrument.

47 OTHER INSTRUMENTATION↗

Simultaneous Measurements of Noncommuting Observables: Positive Transformations and Instrumental Lie Groups

We formulate a general program for describing and analyzing continuous, differential weak, simultaneous measurements of noncommuting observables, which focuses on describing the measuring instrument autonomously, without states. The Kraus operators of such measuring processes are time-ordered products of fundamental differential positive transformations, which generate nonunitary transformation groups that we call instrumental Lie groups. The temporal evolution of the instrument is equivalent to the diffusion of a Kraus-operator distribution function, defined relative to the invariant measure of the instrumental Lie group. This diffusion can be analyzed using Wiener path integration, stochastic differential equations, or a Fokker-Planck-Kolmogorov equation. This way of considering instrument evolution we call the Instrument Manifold Program. We relate the Instrument Manifold Program to state-based stochastic master equations. We then explain how the Instrument Manifold Program can be used to describe instrument evolution in terms of a universal cover that we call the universal instrumental Lie group, which is independent not just of states, but also of Hilbert space. The universal instrument is generically infinite dimensional, in which case the instrument’s evolution is chaotic. Special simultaneous measurements have a finite-dimensional universal instrument, in which case the instrument is considered principal, and it can be analyzed within the differential geometry of the universal instrumental Lie group. Principal instruments belong at the foundation of quantum mechanics. We consider the three most fundamental examples: measurement of a single observable, position and momentum, and the three components of angular momentum. As these measurements are performed continuously, they converge to strong simultaneous measurements. For a single observable, this results in the standard decay of coherence between inequivalent irreducible representations. For the latter two cases, it leads to a collapse within each irreducible representation onto the classical or spherical phase space, with the phase space located at the boundary of these instrumental Lie groups.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗