Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “penetration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converter-interfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. A potential interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a varied-length transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

grid-following inverters↗

Inserting a Low-Refractive-Index Dielectric Rear Reflector into PERC Cells: Challenges and Opportunities

One of the simplest and most effective ways to reduce the operating temperature of photovoltaic systems in the field is to reflect unusable, 'sub-bandgap' light with energies below the cell absorber's bandgap energy. In this work, low-refractive index SiO2 nanoparticle films inserted between c-Si wafers and metal electrodes significantly increase the reflectance of sub-bandgap light in fabricated test structures. These films are then integrated into the standard PERC fabrication sequence, revealing that the reflection benefits remains after some processing steps but are lost in certain conditions. The SiO2 nanoparticle films are easily ablated during laser contact opening, but are undesirably etched during post-laser cleaning. After Al metallization, the fully fabricated devices show enhanced sub-bandgap reflection when annealed at moderate temperatures, but energy-dispersive X-ray spectroscopy shows that high-temperature firing causes unwanted Al penetration into the SiO2 nanoparticle film, compromising reflection.

14 SOLAR ENERGY↗

Quantifying Solar PV Variability at Multiple Timescales for Power Systems Studies: Preprint

Increasing penetration of solar photovoltaics (PV) has concerned power system operators about their ability to balance load and generation over multiple timescales and maintain acceptable frequency profile because of the variability and uncertainty associated with solar PV. This paper focuses on developing metrics to quantify solar PV variability at multiple temporal scales ranging from seconds to an hour to help power system operators and planners better understand and account for solar PV variability under high solar PV penetration. Fourier coefficients of solar irradiation spectrum and average size of solar irradiation ramps over a day are the two metrics that are used to quantity the variability. It is shown that by using the two metrics the days with highest and lowest solar irradiation variability can be identified, which is useful information for operations planning or long-term power system planning studies. The key findings of the paper are (i) single sensor-based variability quantification can significantly exaggerate the variability of a solar PV plant, particularly at seconds to 1-min temporal resolution, (ii) at 1-minute or lower temporal resolutions, single sensor-based variability quantification of an entire plant can be fairly accurate, with the accuracy increasing as the temporal resolution reduces from 1-minute to 1-hour, (iii) at each 1-minute and lower temporal resolutions, maximum solar irradiation ramps appear to be independent of the geographical location of the sensor, and (iv) significant reduction in solar PV plant variability over a region with multiple plants is possible at all temporal scales, but more high quality, high temporal resolution data is needed to quantify the reduction with high confidence.

photovoltaics↗

Identification of Intraday False Data Injection Attack on DER Dispatch Signals

The urgent need for the decarbonization of power grids has accelerated the integration of renewable energy. Concurrently, increasing distributed energy resources (DER) and advanced metering infrastructure (AMI) have transformed the power grids into a more sophisticated cyber-physical system with numerous communication devices. While these transitions provide economic and environmental value, they also impose increased risk of cyber attacks and operation al challenges. This paper investigates the vulnerabilit y of the power grids with high renewable penetration against an intraday false data injection (FDI) attack on DER dispatch signals and proposes a kernel support vector regression (SVR) based detection model as a countermeasure. The intraday FDI attack scenario and the detection model are demonstrated in a numerical experiment using the HCE 187-bus test system.

Kim, Jip↗

Improving Distribution System Operations Using Fleet Control of Electrolyzers

The proliferation of electrolyzers presents an opportunity for grid operators. Fast response times and the use of hydrogen as storage can be leveraged in a symbiotic way to support increasing penetration levels of photovoltaics (PV) in the distribution grid. This work presents the grid integration of an electrolyzer fleet and its control applications to minimize the impact of increasing solar PV penetration in the distribution network. The study involves a feeder model of a real utility circuit from a utility partner with an operational model of a fleet of electrolyzers. The operational improvements are quantified with performance metrics. The metrics show that the fleet control application of the electrolyzers can aid in reducing overvoltages, voltage fluctuations, and control device operations induced by intermittent solar generation. The locational dependence of electrolyzers are also discussed in terms of performance metrics.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

TPCPF: Three-Phase Continuation Power Flow Tool for Voltage Stability Assessment of Distribution Networks With Distributed Energy Resources

This article presents a three-phase unbalanced continuation power flow algorithm for voltage stability assessment of distribution systems with high penetration of distributed energy resources (DERs). Analyzing distribution system voltage stability with DER will allow high penetration of renewable energy necessary for the sustainability goals. The developed algorithm can analyze voltage stability for both the meshed and radial systems and the balanced and unbalanced three-phase distribution systems. The developed tool allows the voltage stability analysis to facilitate the planning, operation, control, and distribution system management. The impact of DER on the voltage stability of several test cases has been analyzed considering constant power (P Q) and regulated-voltage (P V ) modes of operation for DER units. Moreover, different voltage stability case studies are presented to demonstrate the impact of unbalance, load increment, and network topology on the maximum loading capacity. Finally, results using the IEEE 13-node feeder, the 18-bus balanced shipboard system, the 13-node CIGRE benchmark system, and the 136-bus redial distribution feeder demonstrate that the developed continuation power flow tool can efficiently perform voltage stability analysis for active distribution systems.

42 ENGINEERING↗

Probabilistic Sizing of Energy Storage Systems for Reliability and Frequency Security in Wind-Rich Power Grids

The penetration of wind energy has increased significantly in the power grid in recent times. Although wind is abundant, environment-friendly, and cheap, it is variable in nature and does not contribute to system inertia as much as conventional synchronous generators. Coupled with the low inertia contribution, the generation intermittency of wind power leads to reliability and stability issues in the power system. Energy storage systems (ESSs) are among the most prominent alternatives to alleviate these concerns associated with high wind penetration. This paper proposes a planning strategy to size ESS for the reliability and frequency security of wind-rich power grids. A probabilistic methodology for ESS sizing is developed utilizing a composite reliability-based framework with sequential Monte Carlo simulation (MCS). The MCS generates composite reliability indices for the power system, which are employed to obtain the capacity for a reliability energy storage system (RESS). Simultaneously, the MCS-derived probability of synchronization of conventional generators is integrated into an analytical approach for sizing a frequency support energy storage system (FESS). The effect of wind farm dispersion across geographical regions is incorporated in the framework to study possible reductions in the ESS size while maintaining the system reliability and frequency security. Furthermore, the efficacy of the proposed strategy is demonstrated on the RTS-GMLC test system.

25 ENERGY STORAGE↗

Holistic Small-Signal Stability Analysis for Large-Scale Inverter-Intensive Power Systems with Coupled and Full-Order Dynamics from Control Systems and Power Networks

The increasing penetration of inverter-based resources (IBRs) into the existing power systems introduces tremendous benefits for enhanced sustainability but also poses inevitable challenges in terms of insufficient inertia, potential instability, and complex network dynamics, among others. However, the additional coupling introduced by the interactions among gridfollowing (GFL) and grid-forming (GFM) IBRs and the other components (i.e., synchronous generators [SGs], loads, and network, etc.) has not been clearly explored. A holistic, scalable, and quantitative stability analysis framework with the control systems and power networks is still missing. Here, in this paper, to fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established. An extended power flow model with operation dynamics from both generator control schemes and power networks is proposed to provide the varying steady-state operating points for small-signal modeling. The proposed method is compared with MATLAB solvers, and the results show that the proposed approach has a minimum calculation time, which can be less than 12 seconds for a large-scale power system with up to 2,000 buses. Furthermore, a quantitative method is developed to identify the impacts of IBRs on system performance with emphases on the potential stability issues with GFL IBRs, additional benefits of employing GFM IBRs, the feasibility of replacing SGs with GFM IBRs, and the impact of penetration level of different kinds of generation units. Finally, a field island power system is used to verify the proposed approach, and hardware-in-the-loop (HIL) tests are provided to further demonstrate the effectiveness of the proposed analysis.

14 SOLAR ENERGY↗

Safe Deep Reinforcement Learning for Active Distribution System Model Predictive Control with EVs and DERs

The temporal and spatial mismatch between PV generation and electric vehicle (EV) charging and discharging may cause voltage violations in active distribution networks. Despite the widespread use of deep reinforcement learning (DRL) in power system optimization and control, it lacks guarantees on constraint satisfaction during both training and deployment. This paper proposes a Lagrangian-based safe DRL approach for model predictive control (MPC) of active distribution systems with large-scale integration of PVs, EVs, and energy storage systems (ESSs). A Transformer-LSTM time-series model is proposed to forecast EV charging demand, which is then formulated as a constraint to ensure charging requirements are met. Using this prediction, a Lagrangian-based safe soft actor-critic (SAC) framework is developed for real-time control in a three-phase unbalanced distribution system, enforcing voltage safety constraints while optimizing the cumulative net reward. By integrating the forecasting model with multi-period constraints, the proposed framework jointly coordinates PV systems, EV charging and discharging, and ESS scheduling within the MPC horizon. Numerical experiments on a modified IEEE 123-bus system with real-world data show that, under a high PV penetration scenario, the proposed method increases the net reward by 30.74% and reduces average voltage violations from 0.0011 p.u. to 0.0002 p.u. compared with standard SAC. Compared with the optimal power flow (OPF) approach, it achieves similar voltage security while yielding lower line losses. It also maintains real-time control capability, reducing operation latency to 53.21 ms per 15-minute control interval. The proposed method remains effective under varying PV/EV penetrations and load conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Maneuver Planning With Connected and Automated Vehicles for Boosting Traffic Efficiency

Connected and automated vehicles (CAVs) have the potential to improve traffic throughput and achieve a more efficient utilization of the available roadway infrastructure. They also have the potential to reduce energy consumption through traffic motion harmonization, even when operating in mixed traffic with other human-driven vehicles. The key to realizing these potentials are coordinated control schemes that can be implemented in a distributed manner with the CAVs. In this paper, we propose a distributed predictive control framework that features a two-dimensional maneuver planner incorporating explicit coordination constraints between connected vehicles operating in mixed traffic at various penetration levels. Here, the framework includes a distributed implementation of a reference speed assigner that estimates local traffic speed from on-board measurements and communicated information. We present an extensive evaluation of the proposed framework in traffic micro-simulations at various CAV penetrations from traffic flow, energy use, and lane utilization points of view. Results are compared to a baseline scenario with no CAVs, as well as, a benchmark one-dimensional planner.

33 ADVANCED PROPULSION SYSTEMS↗

Modeling of Grid-Forming and Grid-Following Inverters for Dynamic Simulation of Large-Scale Distribution Systems

Historically, distribution system planning studies mainly focused on steady state and quasi-steady state analysis, with limited attention paid to dynamic analysis. This paper develops three-phase, electromechanical models for both grid-forming and grid-following inverters, and integrates them into an open source, three-phase distribution network solver, thereby enabling dynamic simulation of large-scale, three-phase unbalanced distribution systems with high penetration of inverter-based DERs. The proposed inverter models are validated against electromagnetic simulation and field test data from the CERTS/AEP microgrid testbed, and simulated in an islanded 5252 node distribution system in the GridLAB-D simulation environment. Simulation verifies the effectiveness of the proposed inverter models for large-scale distribution system analysis. Finally, study results show that compared to traditional grid-following inverters, the high penetration of grid-forming inverters can improve the voltage and frequency stability of islanded distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parameter Reduction of Composite Load Model Using Active Subspace Method

Over the past decades, the increasing penetration of distributed energy resources (DERs) has dramatically changed the power load composition in the distribution networks. The traditional static and dynamic load models can hardly capture the dynamic behavior of modern loads especially for fault-induced delayed voltage recovery (FIDVR) events. Thus, a more comprehensive composite load model with combination of static load, different types of induction motors, single-phase A/C motor, electronic load and DERs has been proposed by Western Electricity Coordinating Council (WECC). However, due to the large number of parameters and model complexity, the WECC composite load model (WECC CMLD) raises new challenges to power system studies. To overcome these challenges, in this paper, a cutting-edge parameter reduction (PR) approach for WECC CMLD based on active subspace method (ASM) is proposed. Firstly, the WECC CMLD is parameterized in a discrete-time manner for the application of the proposed method. Then, parameter sensitivities are calculated by discovering the active subspace, which is a lower-dimensional linear subspace of the parameter space of WECC CMLD in which the dynamic response is most sensitive. The interdependency among parameters can be taken into consideration by our approach. Finally, the numerical experiments validate the effectiveness and advantages of the proposed approach for WECC CMLD model.

active subspace↗

Encoding Frequency Constraints in Preventive Unit Commitment Using Deep Learning With Region-of-Interest Active Sampling

With the increasing penetration of renewable energy, frequency response and its security are of significant concerns for reliable power system operations. Frequency-constrained unit commitment (FCUC) is proposed to address this challenge. Despite existing efforts in modeling frequency characteristics in unit commitment (UC), current strategies can only handle oversimplified low-order frequency response models and do not consider wide-range operating conditions. This paper presents a generic data-driven framework for FCUC under high renewable penetration. Here, deep neural networks (DNNs) are trained to predict the frequency response using real data or high-fidelity simulation data. Next, the DNN is reformulated as a set of mixed-integer linear constraints to be incorporated into the ordinary UC formulation. In the data generation phase, all possible power injections are considered, and a region-of-interest active sampling is proposed to include power injection samples with frequency nadirs closer to the UFLC threshold, which enhances the accuracy of frequency constraints in FCUC. The proposed FCUC is investigated on the IEEE 39-bus system. Then, a full-order dynamic model simulation using PSS/E verifies the effectiveness of FCUC in frequency-secure generator commitments.

42 ENGINEERING↗

Ambient-Frequency-Data Based System-Level Inertia Estimation Using Physical Equation and its Practice on Hawaii Islands

Here, in this paper, a practical ambient-frequency-data-based inertia estimation method using a physical equation is proposed and validated by real measurement data from Hawaii island grids. With high renewable penetration, accurate inertia estimation is important and urgent. Ambient frequency oscillation always exists in power grids, so the proposed method has advantages of real-time inertia estimation and no need for additional disturbances. This paper first developed the physical equation for inertia estimation to offer a clear mechanism for easy implementation in practice. To apply the proposed method in actual grids, a practical method to extract the ambient frequency oscillation from frequency measurement is further proposed. The inertia estimation using the physical equation is validated by KIUC simulation data and HECO field data, in which error rates are around 2% and 8%, respectively. Practical inertia estimation is challenging due to the large amounts of resources contributing to the power grid's effective inertia, but the method provided in this paper can offer a novel way for practical inertia estimation, which can help renewable penetration to boost carbon-free grid.

14 SOLAR ENERGY↗

Frequency Support From Electric Vehicles for Advancing Renewable Energy Integration

The integration of renewable energy resources (RERs) in the modern power grid is increasing rapidly because of aggressive decarbonization goals, lower costs, and increased government investment. However, higher penetrations of inverter-based generation can lead to frequency stability issues because of reduced system inertia. This paper develops a framework for quantifying the contribution of electric vehicles (EVs) toward providing frequency support to the grid and thus increasing the penetration limit of renewable energy resources (RERs). EVs are considered to provide both inertial response and primary frequency response support to the grid. A stochastic approach incorporating the uncertainties associated with the behavior of EVs is developed to derive the discharge limit of EV aggregators. A multi-machine system frequency response (MM-SFR) model is developed, which incorporates the dynamic virtual inertia and droop coefficients of EV aggregators derived from the EV control modules. Frequency security constraints are developed from this MM-SFR model, which, along with the converter voltage security and low voltage ride-through constraints, are integrated within a nonlinear optimization framework to determine the RER integration limit. Here, the efficacy of the proposed approach is validated using the RTS-GMLC test system.

25 ENERGY STORAGE↗

A Hierarchical Local Electricity Market for a DER-rich Grid Edge

We report with increasing penetration of distributed energy resources (DER) in the distribution system, it is critical to design market structures that enable smooth integration of DERs. A hierarchical local electricity market (LEM) structure is proposed in this paper with a secondary market (SM) at the lower level representing secondary feeders and a primary market (PM) at the upper level, representing primary feeders, in order to effectively use DERs to increase grid efficiency and resilience. The lower level SM enforces budget, power balance, and flexibility constraints and accounts for costs related to consumers, such as their disutility, flexibility limits, and commitment reliability, while the upper level PM enforces grid physics constraints such as power balance and capacity limits, and also minimizes line losses. The hierarchical LEM is extensively evaluated using a modified IEEE-123 bus with high DER penetration, with each primary feeder consisting of at least three secondary feeders. Data from a GridLAB-D model is used to emulate realistic power injections and load profiles over the course of 24 hours. The performance of the LEM is illustrated by delineating the family of power-injection profiles across the primary and secondary feeders as well as corresponding local electricity tariffs that vary across the distribution grid. Through numerical simulations, the hierarchical LEM is shown to improve the efficiency of the market in terms of lowering overall costs, including both the distribution-level locational marginal prices (d-LMP) as well as retail tariffs paid by customers. Together, it represents an overall framework for a Distribution System Operator (DSO) who can provide the oversight for the entire LEM.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchro-Waveform-Based Event Identification Using Multi-Task Time-Frequency Transform Networks

Influenced by the transient dynamics and reduced inertia characteristics of high-penetration renewable energy systems, power system events frequently exhibit distinct characteristics such as high-frequency components including wide-band oscillations and hyper-harmonics. This makes standard systems face challenges including significant latency and reduced accuracy due to limited data resolution. However, current methods face significant limitations, including insufficient pattern capture ability, low noise immunity, limited feature learning, and restricted localization capabilities, thereby hindering real-time performance. To tackle this issue, this paper proposed a novel synchro-waveform-based event identification approach via a Multi-task Time-frequency Transform Network (MTTNet). Initially, a Time-frequency Transform Block (TTB) is developed to extract both local and global information. The TTB leverages both Fourier and S-transforms to derive comprehensive time-frequency information from synchro-waveforms. Subsequently, a multi-task learning strategy is employed to identify the type and distinguish localization of events. Integrating the TTB and multi-task learning, the MTTNet is designed for synchro-waveform-based event identification, incorporating an adaptive weighting strategy and simplified computation for the S-transform. Two different datasets, comprising simulated and actual synchro-waveforms, are collected from the IEEE 123 bus system and a real-world high-penetration renewable energy system using a universal grid analyzer. Extensive experiments on various conditions are carried out. In conclusion, results demonstrated that the MTTNet consistently surpasses both basic and advanced baselines, with maximum improvements of 13.24% and 9.86%, respectively, while reducing the calculation burden by 15-19 times to achieve real-time event identification.

Event identification↗

Multi-Segment Decentralized Control Strategies for Renewables-Rich Microgrids in Extreme Conditions

Microgrids provide a promising approach to accommodating various distributed energy resources (DERs), while requiring significant communication infrastructures that may be affected by extreme conditions such as natural disasters and cyber-attacks. In this paper, a fully decentralized control strategy without the need for communication is proposed for islanded microgrids with high renewables penetration. First, special multi-segment power/frequency characteristic curves are designed, so that different DERs can be automatically coordinated in a prioritized manner such as renewables first to maintain power balance while DER frequencies are regulated at their reference values. Second, piecewise linear served load versus frequency models are designed to prioritize loads according to their significance, so that only noncritical loads will be curtailed as needed while critical loads are supplied without any interruptions during power deficiency. The proposed strategy can effectively deal with various normal and extreme system conditions including 100% renewables penetration, loads and renewables variations, power deficiencies requiring load curtailments, disconnection of existing DERs, connection of new DERs as well as network sectionalization and reconfiguration. As a result, the proposed control strategy is validated in the real-time digital simulator (RTDS) model of the IIT Campus Microgrid to demonstrate its effectiveness in enhancing the resiliency of renewables-rich microgrids in extreme conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗