Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mcnp”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Forward Modeling of Gamma Reaction History Signatures From Anticipated Deuterium-Tritium Filled MagLIF Implosions on Sandia’s Z-Machine

Nuclear reaction history measurements provide a bang time and burn width of Inertial Confinement Fusion (ICF) implosions and are essential for understanding implosion performance to constrain ICF capsule design. When fusion fuel contains Deuterium (D) and Tritium (T) gas, reaction history is informed by measuring the 16.75 MeV gamma rays generated from the D(T,γ) 5 He reaction. Such DT based reaction history measurements have not been made on the Magnetized Laser Inertial Fusion (MagLIF) platform on Sandia’s Z-Machine due to the lack of Tritium being used. The recent development of ICF implosions with tritiated fuel will open the possibility of measuring the gamma reaction history on the Z-Machine. A forward model of the Gamma Reaction History diagnostic on Z (GRH-Z) has been developed using the MCNP6.3 (Monte-Carlo N-Particle) radiation transport code. The model included the Z-Machine geometry of interest to characterize the impact of neutron induced gamma rays on the DT reaction history measurements. In addition, the impulse response functions of the GRH-Z diagnostic to understand the temporal response of the detector, and the minimum yields required to make a reaction history measurement were calculated. This approach also predicted that with T 2 gas doping of MagLIF implosions a reaction history may be made for high performance shots >8e12-2.4e13 depending on the chosen threshold for the detector, with a maximum signal to background ratio of 25%. It was found that for long duration ICF implosions that additional collimation will be needed to prevent the neutron induced gamma rays from modifying the shape of the measured DT reaction history curve.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutronic Safety Analysis of Pu-238 Production at Idaho National Laboratory

This analysis was completed to support the irradiation of plutonium fuel services (PFS) targets in the NEFT in the Advanced Test Reactor (ATR) as a part of the campaign to restart domestic production of plutonium-238 used in radioisotope power systems (RPS) by the National Aeronautical and Space Administration (NASA) and Department of Energy (DOE) Office of Nuclear Energy (NE), Office of Nuclear Infrastructure Program (NE-3). Referred to as the PFS-ATR-GEN1-NEFT experiment, the assembly was designed to hold 46 PFS targets in the NEFT. The scope of this paper is to outline the MOPY method used to calculate the heat generation rates (HGRs), flux, fission density, and quantify the viability of the target design for Pu-238 production in ATR.

07 ISOTOPE AND RADIATION SOURCES↗

Validation of Jezebel Reactivity Coefficients and Sensitivity Analysis

Nuclear data validation is often performed today using criticality measurements. The gold standard for criticality measurements is the International Criticality Safety Benchmark Experiment Project (ICSBEP). The validation specifically focuses on the effective multiplication factor ($k_{eff}$). $K_{eff}$ is a relatively easy parameter to infer and has reduced uncertainty due to being at or above critical. However, while $k_{eff}$ is the most documented parameter and its uncertainties and sensitivities have been evaluated in great detail, it cannot be used as a standalone metric to determine inaccuracies in nuclear data (e.g., cross section data, PFNS, nu), which is based on theory, physics, and differential measurements. The Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) project aims to identify compensating errors in specific isotope nuclear data by optimally designing experiments that are, or are not sensitive to a suite of measurement parameters beyond $k_{eff}$. By identifying parameters that are sensitive to each other, oppositely sensitive, or have substantial magnitude differences in sensitivity, experiments can be designed to constrain questionable nuclear data. One sensitivity that is of particular interest to this project includes the sensitivity of reactivity coefficients. Reactivity coefficients compare reactivity, which is related to $k_{eff}$ at two different states therefore being sensitive to small changes in the system. The most common type of reactivity coefficient measurements is comparison to void for a small sample within the assembly. It is key that the sample sizes are small enough to not affect the flux of the full system. Reactivity coefficients were evaluated for many early experiments to better understand transport corrected cross sections. In fact, ICSBEP includes reactivity coefficient results as “Supplemental Measurements” in appendices for a handful of older benchmarks. One of those benchmarks is Jezebel, the bare Pu critical assembly. This paper compares new simulations of reactivity coefficients for Jezebel, and explores the sensitivity of reactivity coefficients to small changes in nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of Critical Experiments Targeting Epithermal Cross Sections of Tantalum

Sandia National Laboratories (SNL) and Oak Ridge National Laboratory (ORNL) are collaborating to develop a capability to test the epithermal/intermediate cross sections of tantalum (Ta) at the SNL critical experiments facility using the Seven Percent Critical Experiment (7uPCX) fuel. The Sandia Critical Experiments (SCX) Program provides a specialized facility for performing water moderated and reflected critical experiments with UO 2 fuel rod arrays. A history of safe reactor operations and flexibility in reactor core configuration has resulted in the completion of several benchmark critical experiment evaluations that are published in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The critical experiments described here are scheduled to be performed at SCX in fiscal year 2023. Currently, fabrication details for the needed new equipment are being finalized for completion of the procurement process. The experiments will then be executed and documented for publication consideration by the ICSBEP.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Update on Benchmark Analysis of Component Critical Configurations of KRUSTY

Kilowatt Reactor Using Stirling Technology (KRUSTY) is prototype designed as a proof of concept for NASA’s Kilo power program, which was funded in order to create a small reactor for various space applications such as providing power for a colony on Mars or the moon and eventually as a possible option for powering rockets on deep space missions. Before the final prototype design was tested in March 2018, the component critical configuration, which had less external equipment than the prototype design, was created in November 2017. Both of these designs had less external equipment than the final version will have. This component critical con figuration was used to determine the worth of the beryllium oxide (BeO) reflector and of the boron carbide (B4C) control rod as well as creating necessary benchmark configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigation of Application Specific k eff Sensitivities to Existing and New Subcritical and Critical Experiments

Integral subcritical and critical experiments are essential in providing validation of computational codes which improve confidence in the predicted k eff results of specific applications. This work discusses the relevance of existing integral subcritical and critical experiments to applications far reaching across the nuclear complex. These applications include Travelling Wave Reactors (TWR), Kilopower Reactor Using Stirling Technology (KRUSTY), and plutonium reflected by tantalum. The primary goal of this work is to improve knowledge of energy-dependent cross-section sensitivities for specific applications, identify nuclear data gaps in existing experiments, enable an optimized design of new experiments to address these gaps, and design practical new experiments that could be executed at the National Criticality Experiments Research Center (NCERC) that have a high-value to these applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lead Slowing Down Spectrometer Status Report

This report documents the progress that has been completed in the first half of FY2012 in the MPACT-funded Lead Slowing Down Spectrometer project. Significant progress has been made on the algorithm development. We have an improve understanding of the experimental responses in LSDS for fuel-related material. The calibration of the ultra-depleted uranium foils was completed, but the results are inconsistent from measurement to measurement. Future work includes developing a conceptual model of an LSDS system to assay plutonium in used fuel, improving agreement between simulations and measurement, design of a thorium fission chamber, and evaluation of additional detector techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Continuous-Estimator Representation for Monte Carlo Criticality Diagnostics [Slides]

An alternate means of computing diagnostics for Monte Carlo criticality calculations is proposed. Overlapping spherical regions or estimators are placed covering the fissile material with a minimum center-to-center separation of the 'fission distance', which is defined herein, and a radius that is some multiple thereof. Fission neutron production is recorded based upon a weighted average of proximities to centers for all the spherical estimators. These scores are used to compute the Shannon entropy, and shown to reproduce the value, to within an additive constant, determined from a well-placed mesh by a user. The spherical estimators are also used to assess statistical coverage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CRDIAC: Coupled Reactor Depletion Instrument with Automated Control

When modeling the behavior of a nuclear reactor over time, it is important to understand how the isotopes in the reactor will change, or transmute, over that time. This is especially important in the reactor fuel itself. Many nuclear physics modeling codes model how particles interact in the system, but do not model this over time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uranium Neutron Coincidence Collar Model Utilizing 3 He

The Department of Energy Office of Nuclear Safeguards (NA-241) is supporting the project 'Coincidence Counting With Boron-Based Alternative Neutron Detection Technology' at Pacific Northwest National Laboratory (PNNL) for development of an alternative neutron coincidence counter. The goal of this project is to design, build and demonstrate a boron-lined proportional tube based alternative system in a configuration typically used for 3 He-based coincidence counter applications. The specific application selected for boron-lined tube replacement in this project was one of the Uranium Neutron Coincidence Collar (UNCL) designs. This report, providing results for model development of a UNCL, is a deliverable under Task 2 of the project. The current UNCL instruments utilize 3 He tubes. As the first step in developing and optimizing a boron-lined proportional counter based version of the UNCL, models of eight different 3 He-based UNCL detectors currently in use were developed and evaluated. A comparison was made between the simulated results and measured efficiencies for those systems with values reported in the literature. The reported experimental measurements for efficiencies and die-away times agree to within 10%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calculation of Ambient (H*(10)) and Personal (H p (10)) Dose Equivalent from a 252 Cf Neutron Source

The neutron emission rate from radioisotope neutron sources such as 252 Cf sources can be calibrated by the National Institute of Standards and Technology (NIST) by the manganous sulfite bath method. This calibration method does not compute the dose or dose equivalent rate from the source. Because there is no accepted transfer standard for neutron dose measurements, secondary calibration facilities are responsible for determining their own neutron dose factors. This report describes a neutron source and irradiation apparatus in use at the Pacific Northwest National Laboratory Calibration Facility. The neutron source is a SR-Cf-3000 design 252 Cf neutron source. The neutron source is contained in an aluminum transfer capsule that is used to transport the neutron source between its storage location and it’s irradiation location. During irradiations, the source is located in a transfer tube assembly that consists of two concentric aluminum tubes. When moderated neutrons are desired, the transfer tube assembly is surrounded by a sphere that is filled with D 2 O as a moderating medium. Ambient dose equivalent (H*(10)) and Personal dose equivalent (H p (10)) dose rates and dose conversion factors were calculated for moderated and unmoderated neutron spectra based on the data provided in ICRP Publication 74. The neutron fluence-to-dose-equivalent conversion factors calculated for this report are summarized and compared to published values in Table 47. The calculated coefficients for the unmoderated 252 Cf spectra agree very well with published reference values, within about 2%. The calculated coefficients for the D 2 O moderated 252 Cf spectra, however, differ from published reference values by about 22%. The PNNL coefficients are higher than the published values which could be interpreted to mean that the PNNL D 2 O moderated spectrum is harder, i.e. higher average energy, than the spectrum published by the ISO (2000), which formed the basis for the published coefficients. The D 2 O moderating sphere in use at PNNL contains less D 2 O moderator than did the D 2 O moderating sphere that was used to calculate the ISO spectrum and this is the likely reason for much of the spectral differences. The exact location of the 252 Cf activity in the source encapsulation is unknown. Preliminary measurements, not described in this report, indicate that the activity may be offset from the location that has been assumed in the past. Corrections for the offset are being proposed and will be the subject of another report. This report was written in a calculation package format to help meet various Quality Assurance requirements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Validation of a Monte Carlo Based Depletion Methodology Using HFIR Post-Irradiation Measurements

Post-irradiation uranium isotopic atomic densities within the core of the High Flux Isotope Reactor (HFIR) were calculated and compared to uranium mass spectrographic data measured in the late 1960s and early 70s. This study was performed in order to validate a Monte Carlo based depletion methodology for calculating the burn-up dependent nuclide inventory, specifically the post-irradiation uranium

HFIR benchmark MCNP ALEPH depletion power pie post↗

MCNP6 Dose Calculations for the Carousel in the LDRGIF

All calculated results are satisfactory. The 66% confidence intervals for all results are less than 5%. A comparison was made between a simple model and a detailed model. The simple model consists of the source, room walt the carousel AI disks, sample cans, and the samples. The detailed model includes the entire simple model along with the safe, and all of the details of the carousel. There was no difference between the two models for the dose absorbed by the samples. If these calculations are performed in the future, one should use the simple model. The simple model runs faster and the results are easier to understand. Dose rates to various polymers in the carousel assembly were calculated. The source of radiation is a 6.61 curie 137 Cs source. The experiments are planned for Bldg 6631. LK3626 absorbed the largest dose, 791000±554 rads/yr. The lowest absorbed dose is 696000±487 rads/yr. The lowest absorbed dose is for the gold disk #1 and TLDs 1a and 1b, Au disk 658000±3950 rads/yr and TLD 1a 481000±4450 rads/yr. The Au disk with the highest absorbed dose is #3 at 3640000±9460 rads/yr. The TLD with the highest absorbed dose is 6a at 1820000±106 rads/yr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of the High Flux Isotope Reactor HEU to LEU Fuel Conversion on Cold Source Nuclear Heat Generation Rates

Under the sponsorship of the US Department of Energy National Nuclear Security Administration, staff members at the Oak Ridge National Laboratory have been conducting studies to determine whether the High Flux Isotope Reactor (HFIR) can be converted from high enriched uranium (HEU) fuel to low enriched uranium (LEU) fuel. As part of these ongoing studies, an assessment of the impact that the HEU to LEU fuel conversion has on the nuclear heat generation rates in regions of the HFIR cold source system and its moderator vessel was performed and is documented in this report. Silicon production rates in the cold source aluminum regions and few-group neutron fluxes in the cold source moderator were also estimated. Neutronics calculations were performed with the Monte Carlo N-Particle code to determine the nuclear heat generation rates in regions of the HFIR cold source and its vessel for the HEU core operating at a full reactor power (FP) of 85 MW(t) and the reference LEU core operating at an FP of 100 MW(t). Calculations were performed with beginning-of-cycle (BOC) and end-of-cycle (EOC) conditions to bound typical irradiation conditions. Average specific BOC heat generation rates of 12.76 and 12.92 W/g, respectively, were calculated for the hemispherical region of the cold source liquid hydrogen (LH2) for the HEU and LEU cores, and EOC heat generation rates of 13.25 and 12.86 W/g, respectively, were calculated for the HEU and LEU cores. Thus, the greatest heat generation rates were calculated for the EOC HEU core, and it is concluded that the conversion from HEU to LEU fuel and the resulting increase of FP from 85 MW to 100 MW will not impact the ability of the heat removal equipment to remove the heat deposited in the cold source system. Silicon production rates in the cold source aluminum regions are estimated to be about 12.0% greater at BOC and 2.7% greater at EOC for the LEU core in comparison to the HEU core. Silicon is aluminum s major transmutation product and affects mechanical properties of aluminum including density, neutron irradiation hardening, swelling, and loss of ductility. Because slightly greater quantities of silicon will be produced in the cold source moderator vessel for the LEU core, these effects will be slightly greater for the LEU core than for the HEU core. Three-group (thermal, epithermal, and fast) neutron flux results tallied in the cold source LH2 hemisphere show greater values for the LEU core under both BOC and EOC conditions. The thermal neutron flux in the LH2 hemisphere for the LEU core is about 12.4% greater at BOC and 2.7% greater at EOC than for the HEU core. Therefore, cold neutron scattering will not be adversely affected and the 4 12 neutrons conveyed to the cold neutron guide hall for research applications will be enhanced.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗