Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “materials modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Mechanical Thrombectomy of Iliac Vein Thrombosis in a Pig Model Using the Rotarex and Aspirex Catheters

Purpose: To investigate the efficacy and safety of mechanical thrombectomy for iliac vein thrombosis using Rotarex and Aspirex catheters in a pig model. Materials and Methods: Iliac vein thrombosis was induced in six pigs by means of an occlusion-balloon catheter and thrombin injection. The presence of thrombi was verified by digital subtraction angiography (DSA) and computed tomography (CT). Thrombectomy was performed using 6F and 8F Rotarex and 6F, 8F, and 10F Aspirex catheters (Straub Medical AG, Wangs, Switzerland). After intervention, DSA and CT were repeated to evaluate the efficacy of mechanical thrombectomy and to exclude local complications. In addition, pulmonary CT was performed to rule out pulmonary embolism. Finally, all pigs were killed, and iliac veins were dissected to perform macroscopic and histological examination. Results: Thrombus induction was successfully achieved in all animals as verified by DSA and CT. Subsequent thrombectomy lead to incomplete recanalization of the iliac veins with residual thrombi in all cases. However, the use of the 6F and 8F Rotarex catheters caused vessel perforation and retroperitoneal hemorrhage in all cases. Application of the Aspirex device caused one small transmural perforation in a vessel treated with a 10F Aspirex catheter, and this was only seen microscopically. Pulmonary embolism was detected in one animal treated with the Rotarex catheters, whereas no pulmonary emboli were seen in animals treated with the Aspirex catheters. Conclusion: The Aspirex catheter allowed subtotal and safe recanalization of iliac vein thrombosis. In contrast, the use of the Rotarex catheter caused macroscopically obvious vessel perforations in all cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Alcohol and Onyx Mixture for Embolization: Feasibility and Proof of Concept in Both In Vitro and In Vivo Models

IntroductionOnyx and ethanol are well-known embolic and sclerotic agents that are frequently used in embolization. These agents present advantages and disadvantages regarding visibility, injection control and penetration depth. Mixing both products might yield a new product with different characteristics. The aim of this study is to evaluate the injectability, radiopacity, and mechanical and occlusive properties of different mixtures of Onyx 18 and ethanol in vitro and in vivo (in a swine model).Materials and MethodsVarious Onyx 18 and ethanol formulations were prepared and tested in vitro for their injectability, solidification rate and shrinkage, cohesion and occlusive properties. In vivo tests were performed using 3 swine. Ease of injection, radiopacity, cohesiveness and penetration were analyzed using fluoroscopy and high-resolution CT.ResultsAll mixtures were easy to inject through a microcatheter with no resistance or blockage in vitro and in vivo. The 50%-ethanol mixture showed delayed copolymerization with fragmentation and proximal occlusion. The 75%-ethanol mixture showed poor radiopacity in vivo and was not tested in vitro. The 25%-ethanol mixture showed good occlusive properties and accepted penetration and radiopacity.ConclusionMixing Onyx and ethanol is feasible. The mixture of 25% of ethanol and 75% of Onyx 18 could be a new sclero-embolic agent. Further research is needed to study the chemical changes of the mixture, to confirm the significance of the added sclerotic effect and to find out the ideal mixture percentages.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Accumulation and Effects of Liposomal Doxorubicin in Tissues Treated by Radiofrequency Ablation and Irreversible Electroporation in Liver: In Vivo Experimental Study on Porcine Models

Purpose: To compare the accumulation and effect of liposomal doxorubicin in liver tissue treated by radiofrequency ablation (RFA) and irreversible electroporation (IRE) in in vivo porcine models. Materials and Methods: Sixteen RFA and 16 IRE procedures were performed in healthy liver of two groups of three pigs. Multi-tined RFA parameters included: 100 W, target temperature 105°C for 7 min. 100 IRE pulses were delivered using two monopolar electrodes at 2250 V, 1 Hz, for 100 µsec. For each group, two pigs received 50 mg liposomal doxorubicin (0.5 mg/kg) as a drip infusion during ablation procedure, with one pig serving as control. Samples were harvested from the central and peripheral zones of the ablation at 24 and 72 h. Immunohistochemical analysis to evaluate the degree of cellular stress, DNA damage, and degree of apoptosis was performed. These and the ablation sizes were compared. Doxorubicin concentrations were also analyzed using fluorescence photometry of homogenized tissue. Results: RFA treatment zones created with concomitant administration of doxorubicin at 24 h were significantly larger than controls (2.5 ± 0.3 cm vs. 2.2 ± 0.2 cm; p = 0.04). By contrast, IRE treatment zones were negatively influenced by chemotherapy (2.2 ± 0.4 cm vs. 2.6 ± 0.4 cm; p = 0.05). At 24 h, doxorubicin concentrations in peripheral and central zones of RFA were significantly increased in comparison with untreated parenchyma (0.431 ± 0.078 µg/g and 0.314 ± 0.055 µg/g vs. 0.18 ± 0.012 µg/g; p < 0.05). Doxorubicin concentrations in IRE zones were not significantly different from untreated liver (0.191 ± 0.049 µg/g and 0.210 ± 0.049 µg/g vs. 0.18 ± 0.012 µg/g). Conclusions: Whereas there is an increased accumulation of periprocedural doxorubicin and an associated increase in ablation zone following RFA, a contrary effect is noted with IRE. These discrepant findings suggest that different mechanisms and synergies will need to be considered in order to select optimal adjuvants for different classes of ablation devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vivo Feasibility of Arterial Embolization with Permanent and Absorbable Suture: The FAIR-Embo Concept

Purpose: Arterial embolization has been shown to be effective and safe for the management of bleeding, especially for postpartum and pelvic traumatic bleeding. We propose to evaluate the proof of concept of feasibility and effectiveness of arterial embolization with absorbable and non-absorbable sutures in a porcine model. Materials and Methods: In the acute setting (n = 1), several different arteries (mesenteric, splenic, pharyngeal, kidney) were embolized using non-absorbable sutures (NAS): Mersutures™ braided sutures (polyethylene terephthalate). In the chronic setting (n = 3), only lower pole renal arteries were embolized. On the right side, NAS was used, whereas on the left side embolization was realized with absorbable suture (AS): Vicryl{sup ®} braided suture (polyglactin 910). The chronic group was followed for 3 months. The pigs received contrast-enhanced CT the day before embolization (D-1), after the embolization (D0), at 1 month and 3 months after embolization (M1 and M3); digital subtraction angiography (DSA) was done at D0 and M3 and histological analysis at M3. Results: All vascular targets were effectively embolized without any pre- or postoperative complications. Both DSAs and CTs at M3 showed a 100% recanalization rate for the AS embolization and a partial reversal rate for the NAS embolization. A renal hypotrophy in the embolized region was observed during both the M1 and M3 scans for both sutures (AS and NAS) with a clear hypotrophy for the NAS embolized kidney. Conclusion: Embolization by AS and NAS (FAIR-Embo) is a feasible and effective treatment which opens up the possibility of global use of this inexpensive and widely available embolization agent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon-Expandable Biodegradable Stents Versus Self-Expandable Metallic Stents: A Comparison Study of Stent-Induced Tissue Hyperplasia in the Rat Urethra

Purpose: To compare the degrees of stent-induced tissue hyperplasia of balloon-expandable, biodegradable stents (BEBSs) with those of self-expandable metallic stents (SEMSs) in a rat urethral model. Materials and Methods: A total of 20 rats were randomized into two groups. The BEBS group (n = 10) received a poly-l-lactic acid (PLLA) biodegradable stent. The SEMS group (n = 10) received a nitinol bare stent. All rats were killed eight weeks after stent placement. The degree of stent-induced tissue hyperplasia was assessed by comparing the results of retrograde urethrography and histologic examination between the two groups. Results: Stent placement was technically successful in all rats. Two rats in the BEBS group were excluded due to procedure-related death. The mean luminal diameter of stented urethra on urethrograms was not significantly different at 4 and 8 weeks between the two groups. On histologic analysis, the percentage of granulation tissue area (p < 0.001) and the thickness of papillary projection (p < 0.001) were significantly higher in the BEBS group compared with the SEMS group. The inflammatory cell infiltration showed a clear tendency to significance (p = 0.050). There were no statistical differences in the number of epithelial layers and the thickness of submucosal fibrosis between the two groups. Conclusion: Formation of stent-induced tissue hyperplasia was significantly evident in the rat urethra with similar degrees between the BEBS and the SEMS. The BEBS was associated with a thicker papillary projection and larger granulation tissue area resulting from higher inflammation compared with the SEMS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unveiling mechanism of surface-guided platinum nanowire growth

We report surface-guided growth of non-planar nanowires on functional substrates offers the new opportunity to precisely control their diameter, length, density and alignment, which will greatly benefit their direct integration into practical devices for large-scale applications. However, control of noble metal nanowires growth and arrangement remains a great challenge, and the mechanistic understanding is still limited. Herein, we choose Pt as a model material system to study the synthesis conditions required to control the in situ growth of aligned Pt nanowires on flat titanium substrate via a one-step and room-temperature green chemical synthesis process in aqueous solution. Most importantly, it is for the first time discovered that ordered nanoarrays and self-assembled nanoflowers can be directly grown on flat Ti substrate by merely adjusting the reaction times, without use of any soft/hard templates, surfactants and organic solvents. The proposed surface-guided growth mechanisms for nanoarray and nanoflower formation in this study may shed light on understanding of oriented arrangement/assembly of one-dimensional Pt nanowires into desirable morphologies for a variety of practical device applications.

Pt nanoflower↗

Ultrasonic Attenuation Due to Grain Boundary Scattering in Pure Niobium

Experimental confirmation of various grain scattering theories exist but there are still outstanding questions concerning the characterization of microstructure using ultrasound. In this study, high purity niobium serves as a model material devoid of extrinsic scattering centers (e.g., voids, precipitates, second phase particles etc.) A range of microstructures were obtained by annealing in ultrahigh vacuum at different temperatures (600–800°C) after routine cold-rolling and recrystallization heat treatment. Ultrasonic attenuation is measured as a function of a frequency for each sample. For the samples with an intermediate grain size (typically ∼50 μm), attenuation follows a power law dependence on frequency with an exponent of n∼1.6, which is close to the prediction, n=2, of classical Stochastic scattering theory. However, quantitative comparison shows that the observed attenuation is higher than predicted by the classical theory. The Stanke-Kino unified grain scattering theory may provide an explanation for the lower frequency dependence than traditional theories predict, though it still under predicts the magnitude of the attenuation. In any event, the resulting empirical relations provide a useful approach for practical grain size measurement with an acceptable level of uncertainty. The effect of a layered microstructure typical of some sheets/plates is discussed.

36 MATERIALS SCIENCE↗

Effect of Fragile Speckle Patterns on Accuracy of Digital Volume Correlation

Due to challenges in generating high-quality 3D speckle patterns for Digital Volume Correlation (DVC) strain measurements, DVC experiments often utilize the intrinsic texture and contrast of composite microstructures. One common deficiency of these natural speckle patterns is their poor durability under large deformations, which can lead to decorrelation and inaccurate strain measurements. Using syntactic foams as a model material, the effects of speckle pattern degradation on the accuracy of DVC displacement and strain measurements are assessed with both experimentally-acquired and numerically-generated images. It is shown that measurement error can be classified into two regimes as a function of the percentage of markers that have disappeared from the speckle pattern. For minor levels of damage beneath a critical level of damage, displacement and strain error remained near the noise floor of less than 0.05 voxels and 100 με, respectively; above this level, error rapidly increased to unacceptable levels above 0.2 voxels and 10,000 με. This transition occurred after 30%–40% of the speckles disappeared, depending on characteristics of the speckle pattern and its degradation mechanisms. Furthermore, these results suggest that accurate DVC measurements can be obtained in many types of fragile materials despite severe damage to the speckle pattern.

42 ENGINEERING↗

An Integrated High-Speed Microstructural Characterization Method Using Simultaneous XRD, Stereo-DIC, and PCI

High-speed characterization of the deformation mechanisms in polycrystalline metals requires the quantification of full strain fields and local microstructural evolutions simultaneously. In this paper, we present a novel experimental method to integrate phase-contrast imaging (PCI), stereographic digital image correlation (stereo-DIC), and full-ring X-ray diffraction (XRD) to allow for the simultaneous characterization of polycrystalline metals at 1MHz or higher. A Kolsky bar was integrated into the synchrotron X-ray source in Sector 32 ID-B at the Advance Photon Source (APS) at Argonne National Laboratory. When the sample is dynamically loaded, the diagnostic methods of full-ring XRD, PCI, and stereo-DIC are properly synchronized to record the deformation behavior at both continuum and microstructural scales as a function of the loading history. An advanced high-strength steel (AHSS) is used as a model material to demonstrate the capabilities of this new experimental method.

36 MATERIALS SCIENCE↗

Building Toward the Future in Chemical and Materials Simulation with Accessible and Intelligently Designed Web Applications

Over the last few decades, significant progress has been made in the development and use of electronic structure and other molecular simulation methods. As these methods become more mature and are able to simulate larger and more complex chemical simulations, the need for improvement in scientific visualization, molecular builders, simplified input to simulation methods, and the development of new approaches and languages to describe simulations, along with workflows to carry them out, becomes more apparent. In this chapter, we describe our recent efforts in developing a prototype open-source computational tool called Arrows that combines NWChem, SQL and NoSQL databases, email, web APIs, and web applications in a way that make molecular and materials modeling accessible to all scientists and engineers. At the same time, because of its simplified input, it provides a framework for expert users to carry out large numbers of calculations and run complex workflows.

Achieving high strength and ductility in traditionally brittle soft magnetic intermetallics via additive manufacturing

Intermetallic alloys possess exceptional soft magnetic properties, including high permeability, low coercivity, and high saturation induction, but exhibit poor mechanical properties that make them impractical to bulk process and use at ideal compositions. We used laser-based Additive Manufacturing to process traditionally brittle Fe–Co and Fe–Si alloys in bulk form without macroscopic defects and at near-ideal compositions for electromagnetic applications. The binary Fe–50Co, as a model material, demonstrated simultaneous high strength (600–700 MPa) and high ductility (35%) in tension, corresponding to a ~300% increase in strength and an order-of-magnitude improvement in ductility relative to conventionally processed material. Atomic-scale toughening and strengthening mechanisms, based on engineered multiscale microstructures, are proposed to explain the unusual combination of mechanical properties. Here, this work presents an instance in which metal Additive Manufacturing processes are enabling, rather than limiting, the development of higher-performance alloys.

36 MATERIALS SCIENCE↗

An additive manufacturing design approach to achieving high strength and ductility in traditionally brittle alloys via laser powder bed fusion

Additive Manufacturing (AM) presents unprecedented opportunities to enable design freedom in parts that are unachievable via conventional manufacturing. However, AM-processed components generally lack the necessary performance metrics for widespread commercial adoption. We present a novel AM processing and design approach using removable heat sink artifacts to tailor the mechanical properties of traditionally low strength and low ductility alloys. The design approach is demonstrated with the Fe-50 at.% Co alloy, as a model material of interest for electromagnetic applications. AM-processed components exhibited unprecedented performance, with a 300 % increase in strength and an order-of-magnitude improvement in ductility relative to conventional wrought material. These results are discussed in the context of product performance, production yield, and manufacturing implications toward enabling the design and processing of high-performance, next-generation components, and alloys.

36 MATERIALS SCIENCE↗

In vivo study of breast carcinoma radiosensitization by targeting eIF4E

Highlights: Black-Right-Pointing-Pointer eIF4E is associated with the formation and progression for breast cancer. Black-Right-Pointing-Pointer pSecX-t4EBP1 can downregulated the expression of eIF4E in direct binding. Black-Right-Pointing-Pointer We transfected pSecX-t4EBP1 into a mouse xenograft model. Black-Right-Pointing-Pointer It can significantly inhibit tumor growth and enhance the radiosensitivity. Black-Right-Pointing-Pointer The possible mechanism is downregulation of HIF-1{alpha} expression. -- Abstract: Background: Eukaryotic initiation factor eIF4E, an important regulator of translation, plays a crucial role in the malignant transformation, progression and radioresistance of many human solid tumors. The overexpression of this gene has been associated with tumor formation in a wide range of human malignancies, including breast cancer. In the present study, we attempted to explore the use of eIF4E as a therapeutic target to enhance radiosensitivity for breast carcinomas in a xenograft BALB/C mice model. Materials and methods: Ninety female BALB/C mice transfected with EMT-6 cells were randomly divided into six groups: control, irradiation (IR), pSecX-t4EBP1, pSecX-t4EBP1 + irradiation, pSecX and pSecX + irradiation. At the end of the experiments, all mice were sacrificed, the xenografts were harvested to measure the tumor volume and mass, and the tumor inhibition rates were calculated. Apoptosis was detected with a flow cytometric assay. Immunohistochemistry was used to detect the expression of HIF-1{alpha}. Results: The xenografts in pSecX-t4EBP1 mice showed a significantly delayed growth and smaller tumor volume, with a higher tumor inhibition rate compared with the control and pSecX groups. A similar result was obtained in the pSecX-t4EBP1 + IR group compared with IR alone and pSecX + irradiation. The expression of HIF-1{alpha} in the tumor cells was significantly decreased, while the apoptosis index was much higher. Conclusions: pSecX-t4EBP1 can significantly inhibit tumor growth and enhance the radiosensitivity of breast carcinoma xenografts in BALB/C mice. This is possibly associated with the downregulation of HIF-1{alpha} expression, which suggests that pSecX-t4EBP1 may serve as an ideal molecular target for the radiosensitization of breast carcinoma.

60 APPLIED LIFE SCIENCES↗

Embedded smoothed particle hydrodynamics

In this paper, a hybrid method for embedding a meshfree smoothed particle hydrodynamics into mesh-based ALE hydro schemes is presented. The method relies on the embedded mesh framework presented in Puso et al. (2015, 2012) and utilizes SPH (Owen, 2010) in the solid foreground; when an appropriate damage or failure model is used with SPH, it becomes a natural way to model material fracture and cracking in high-explosive driven experiments. Overall, we provide various examples which validate the coupling between SPH and the embedded mesh method.

42 ENGINEERING↗

Towards improved speed and accuracy of laser powder bed fusion simulations via multiscale spatial representations

Due to the growing popularity of laser powder bed fusion (LPBF) as a metal additive manufacturing technique, there is a strong need to be able to accurately predict build outcomes. Full fidelity simulations of this process are not feasible due to the vast range of length and time scales inherent to it. While part-scale codes for simulating residual stress and distortion have shown reasonable predictive capability, they often neglect many aspects of the process occurring over smaller length/time scales, and thus are unable to capture effects of process parameter adjustments or the behavior of fine features. One way of capturing aspects at more refined length scales is through the use of adaptive mesh refinement (AMR). AMR allows for the process to be simulated at scales approaching the physical spatial dimensions without drastically increasing the total degrees of freedom in the simulation. This manuscript describes the implementation of an AMR algorithm within a multiphysics, parallelized finite element code, and its application to the LPBF problem. In this work, part-scale examples are provided where the use of AMR has allowed for higher fidelity thermal and thermomechanical simulations, as compared to experimental measurements. Results from these higher resolution simulations show that while AMR is a necessary component for increased accuracy in a computationally efficient manner, other improvements are also necessary, including handling of the multiple time scales inherent to the problem and the need for improved AM-specific material models.

42 ENGINEERING↗

Toward an Understanding of Surface Layer Formation, Growth, and Transformation at the Glass–Fluid Interface

Silicate glass is a metastable and durable solid that has application to a number of energy and environmental challenges (e.g., microelectronics, fiber optics, and nuclear waste storage). If allowed to react with water over time silicate glass develops an altered layer at the solid-fluid interface. In this study, we used borosilicate glass (LAWB45) as model material to develop a robust understanding of altered layer formation (i.e., amorphous hydrated surface layer and crystalline reaction products). Experiments were conducted at high surface area-to-volume ratio (~200,000 m-1) and 90 °C in the pressurized unsaturated flow (PUF) apparatus for 1.5-years to facilitate the formation of thick altered layers and allow for the effluent solution chemistry to be monitored continuously. A variety of microscopy techniques were used to characterized reacted grains and suggest the average altered layer thickness is 13.2 ± 8.3 μm with the hydrated and clay layer representing 74.8% and 25.2% of the total altered layer, respectively. This estimate is within the experimental error of the value estimated from the B release rate data (~10 ±1 μm/yr) over the 1.5-year duration. PeakForce® quantitative nanomechanical mapping results suggest the hydrated layer has a modulus that ranges between ~20 to 40 GPa, which is in the range of porous silica that contains from ~20 to ~50% porosity, yet significantly lower than dense silica (~70 to 80 GPa). Scanning transmission electron microscopy (STEM) images confirm the presence of pores and an analysis of a higher resolution image of a region provides a qualitative estimate of ≥ 22% porosity in this layer with variations in the hydrated layer in void volume with increasing distance from the unaltered glass. Chemical composition analyses, based on a combination of time-of-flight secondary-ion mass spectrometry (ToF-SIMS) and scanning electron microscopy with X-ray energy dispersive spectroscopy (EDS) and STEM-EDS, clearly show that the altered layer is mainly composed of Al, H, Si, and O with the clay layer being enriched in Li, Zn, Fe, and Mg. The amorphous hydrated layer is enriched in Ca, H, and Zr with a minor amount of K. Furthermore, ToF-SIMS results also suggest the B profile is anti-correlated with the H profile in the hydrated layer. Our selected-area electron diffraction results suggest the structure of the hydrated layer closely resembles opal-AG (amorphous gel-like) with an average crystallite size of ~0.7 nm which is smaller than the critical nucleus for silica nanoparticles (i.e., 1.4 to 3 nm). These results suggest the hydrated layer is more consistent with a polymeric gel rather than a colloidal gel and is comprised of molecular units (<1 nm in size) that result from the difficult to hydrolyze bonds, such as Si—O—Zr units, during the glass corrosion process. The size of individual particles or molecular units is a function of formation conditions (e.g., pH, ionic strength, nano-confinement, solute composition) in the hydrated layer.

36 MATERIALS SCIENCE↗

Dual-scale folding in cutting of commercially pure aluminum alloys

We examine a, hitherto, little-studied and curious machining chip morphology, with tell-tale signs of folding at two different length scales, that is common in cutting of certain ductile and highly strain-hardening metals like soft aluminum alloys, tantalum and niobium. This chip morphology does not appear in the usual catalogues of common chip types. The mechanics of formation of the “dual-scale folded chip” is studied in model material systems of commercially pure aluminum alloys (AA 1100 and AA 8040), that prominently exhibit this chip morphology. The flow, folding and associated plastic instabilities are investigated using micro/macro structure observations of the chip in a plane-strain cutting framework, with high-speed in situ imaging and image analysis of material flow; and force measurements. The smaller-scale folding is shown to develop in the primary deformation zone while the larger-scale folding occurs as the chip traverses the rake face of the tool. The resulting chip is composed of irregularly-spaced large folds, superimposed onto which are the quasi periodic small folds. The representative wavelengths of the two folds differ on average by an order of magnitude, 0.1 mm vs. 2 mm. The observations reveal a direct coupling between the material flow and chip morphology, and how specific attributes of the dual-scale folded chip arise from the flow mechanism. Plastic buckling is found to play a key role in the folding at both length scales. The small-scale folds are characteristic of a sinuous plastic flow mode, while the large-scale folding is characterized by buckling and stick-slip along the tool rake face, triggered by adhesive pinning of the chip to the tool. Important consequences of the dualscale folding are very large cutting forces, and force oscillations of large amplitude, despite the alloys being very soft, only ~ 25 HV. Here, the dual-scale folding is why many of these alloys are classified as “gummy” to machine. Since the dual-scale folded chip is associated with large cutting forces and poor surface quality, there is much to be gained by disrupting this flow type in practical machining applications. Methods for controlling the folding to improve machining performance with the gummy alloys are briefly discussed.

36 MATERIALS SCIENCE↗

A sharp interface Lagrangian-Eulerian method for flexible-body fluid-structure interaction

This paper introduces a sharp-interface approach to simulating fluid-structure interaction (FSI) involving flexible bodies described by general nonlinear material models and across a broad range of mass density ratios. This new flexible-body immersed Lagrangian-Eulerian (ILE) scheme extends our prior work on integrating partitioned and immersed approaches to rigid-body FSI. Our numerical approach incorporates the geometrical and domain solution flexibility of the immersed boundary (IB) method with an accuracy comparable to body-fitted approaches that sharply resolve flows and stresses up to the fluid-structure interface. Unlike many IB methods, our ILE formulation uses distinct momentum equations for the fluid and solid subregions with a Dirichlet-Neumann coupling strategy that connects fluid and solid subproblems through simple interface conditions. As in earlier work, we use approximate Lagrange multiplier forces to treat the kinematic interface conditions along the fluid-structure interface. This penalty approach simplifies the linear solvers needed by our formulation by introducing two representations of the fluid-structure interface, one that moves with the fluid and another that moves with the structure, that are connected by stiff springs. This approach also enables the use of multi-rate time stepping, which allows us to use different time step sizes for the fluid and structure subproblems. Our fluid solver relies on an immersed interface method (IIM) for discrete surfaces to impose stress jump conditions along complex interfaces while enabling the use of fast structured-grid solvers for the incompressible Navier-Stokes equations. The dynamics of the volumetric structural mesh are determined using a standard finite element approach to large-deformation nonlinear elasticity via a nearly incompressible solid mechanics formulation. This formulation also readily accommodates compressible structures with a constant total volume, and it can handle fully compressible solid structures for cases in which at least part of the solid boundary does not contact the incompressible fluid. Selected grid convergence studies demonstrate second-order convergence in volume conservation and in the pointwise discrepancies between corresponding positions of the two interface representations as well as between first and second-order convergence in the structural displacements. The time stepping scheme is also demonstrated to yield second-order convergence. To assess and validate the robustness and accuracy of the new algorithm, comparisons are made with computational and experimental FSI benchmarks. Test cases include both smooth and sharp geometries in various flow conditions. Furthermore, we also demonstrate the capabilities of this methodology by applying it to model the transport and capture of a geometrically realistic, deformable blood clot in an inferior vena cava filter.

97 MATHEMATICS AND COMPUTING↗