Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Tailoring Interfaces for Enhanced Methanol Production from Photoelectrochemical CO 2 Reduction

Efficient and stable photoelectrochemical reduction of CO 2 into highly reduced liquid fuels remains a formidable challenge, which requires an innovative semiconductor/catalyst interface to tackle. In this study, we introduce a strategy involving the fabrication of a silicon micropillar array structure coated with a superhydrophobic fluorinated carbon layer for the photoelectrochemical conversion of CO 2 into methanol. The pillars increase the electrode surface area, improve catalyst loading and adhesion without compromising light absorption, and help confine gaseous intermediates near the catalyst surface. The superhydrophobic coating passivates parasitic side reactions and further enhances local accumulation of reaction intermediates. Upon one-electron reduction of the molecular catalyst, the semiconductor–catalyst interface changes from adaptive to buried junctions, providing a sufficient thermodynamic driving force for CO 2 reduction. These structures together create a unique microenvironment for effective reduction of CO 2 to methanol, leading to a remarkable Faradaic efficiency reaching 20% together with a partial current density of 3.4 mA cm –2 , surpassing the previous record based on planar silicon photoelectrodes by a notable factor of 17. Furthermore, this work demonstrates a new pathway for enhancing photoelectrocatalytic CO 2 reduction through meticulous interface and microenvironment tailoring and sets a benchmark for both Faradaic efficiency and current density in solar liquid fuel production.

14 SOLAR ENERGY↗

Subsonic Ultra Green Aircraft Research: Phase IV Final Report – Volume I Mach 0.80 Transonic Truss-Braced Wing High-Speed Design Report

This design report summarizes work performed by the Boeing Subsonic Ultra-Green Aircraft Research (SUGAR) team from December 2016 through June 2018. In Phase IV of the SUGAR program, Boeing is working to improve the productivity of a TTBW configuration by updating the Mach 0.745 vehicle concept to operate efficiently at Mach 0.80. Due to the aerodynamic and structural design challenges associated with adapting the design to a higher speed, design tasks have been broken into several subtasks. The information in this report (Volume I) documents the development of a Mach 0.80 vehicle outer mold line, maturation of TTBW structural concepts, and presents a preliminary high-liftsystem assessment. Results from these studies were integrated into an aircraft-level performance code that estimates the benefits of TTBW technology, both on its own and as a part of the SUGAR integrated technology suite. The aerodynamic performance results presented herein detail the high cruise efficiency of the TTBW concept operating at M=0.80. Results from the RANS code OVERFLOW indicate that the TTBW is aerodynamically well suited for operation at the design M=0.80 transonic cruise Mach number. Aircraft-level performance predictions show that the TTBW offers a 7.2% improvement in fuel burn (per seat) for an economic mission of 900nm, and a 9.0% improvement in fuel burn (per seat) for a 3500nm mission with full passenger payload, relative to an aspect ratio 13 conventional tube and wing configuration of equivalent technology. Integration of the TTBW performance benefits into the SUGAR technology suite shows a 55.9% reduction in fuel burn (for the economic mission) relative to the reference (SUGAR Free) aircraft, which is a consistently sized traditional cantilever wing, single-aisle transport typical of the 2008 fleet. This benefit does not include the performance improvement potential of hybrid-electric systems studied in earlier phases of the SUGAR program Structural concept development work completed in Phase IV has identified several strut attachment concepts that are worth additional development activity – an inboard strut attachment swivel joint concept (which enables the strut to carry axial loads while avoiding strut bending induced by wing twist during flight) significantly simplifies the construction of the main strut. An outboard offset strut attachment concept holds significant potential for further reductions in wing-strut interference drag. Based on work performed to date on Phase IV and the previous phases of the SUGAR program, the TTBW concept continues to remain a viable concept for significantly improving the performance of future aircraft. High-fidelity aerodynamic analysis of the Mach 0.80 TTBW aircraft has shown fuel burn improvement that has exceeded initial expectations despite the increase in cruise Mach number. Structural concept maturation has continued to refine the TTBW structure, and has found no obvious ‘show-stoppers’ to date. Therefore, the potential benefit of improved performance through the use of a very high aspect ratio strut-braced wing continues to warrant additional study

SUGAR↗

Load Distribution in Transmissions "Split"

The transmission system of a helicopter must meet particularly critical requirements. It must transmit engine power to the rotor, at the same time ensuring a typical speed reduction of 60 to 1. It must also be safe, reliable, light, and reach a high level of performance while, at the same time, it must produce few vibrations and little noise. Helicopter transmissions have achieved high-level performances thanks to the combination of analyses, experiments, and the application of practical field experience. However, the new generation of helicopters will require transmission systems that are even safer, lighter, less noisy, and more reliable.

Krantz, Timothy L.↗

Experimental Characterization of Hysteresis in a Revolute Joint for Precision Deployable Structures

Recent studies of the micro-dynamic behavior of a deployable telescope metering truss have identified instabilities in the equilibrium shape of the truss in response to low-energy dynamic loading. Analyses indicate that these micro-dynamic instabilities arise from stick-slip friction within the truss joints (e.g., hinges and latches). The present study characterizes the low-magnitude quasi-static load cycle response of the precision revolute joints incorporated in the deployable telescope metering truss, and specifically, the hysteretic response of these joints caused by stick-slip friction within the joint. Detailed descriptions are presented of the test setup and data reduction algorithms, including discussions of data-error sources and data-filtering techniques. Test results are presented from thirteen specimens, and the effects of joint preload and manufacturing tolerances are investigated. Using a simplified model of stick-slip friction, a relationship is made between joint load-cycle behavior and micro-dynamic dimensional instabilities in the deployable telescope metering truss.

Lake, Mark S.↗

Traction Drives for Zero Stick-Slip Robots, and Reaction Free, Momentum Balanced Systems

Two differential (dual input, single output) drives (a roller-gear and a pure roller), and a momentum balanced (single input, dual output) drive (pure roller ) were designed, fabricated, and tested. The differential drives are each rated at 295 rad/sec (2800 rpm) input speed, 450 N-m (4,000 in-lbf) output torque. The momentum balanced drive is rated at 302 rad/sec (2880 rpm) input speed, and dual output torques of 434N-m (3840 in-lbf). The Dual Input Differential Roller-Gear Drive (DC-700) has a planetary roller-gear system with a reduction ratio (one input driving the output with the second input fixed) of 29.23: 1. The Dual Input Differential Roller Drive (DC-500) has a planetary roller system with a reduction ratio of approximately 24:1. Each of the differential drives features dual roller-gear or roller arrangements consisting of a sun, four first row planets, four second row planets, and a ring. The Momentum Balanced (Grounded Ring) Drive (DC-400) has a planetary roller system with a reduction ratio of 24:1 with both outputs counterrotating at equal speed. Its single roller cluster consists of a sun, five first and five second row planets, a roller cage or spider and a ring. Outputs are taken from both the roller cage and the ring which counterrotate. Test results reported for all three drives include angular and torque ripple (linearity and cogging), viscous and Coulomb friction, and forward and reverse power efficiency. Of the two differential drives, the Differential Roller Drive had better linearity and less cogging than did the Differential Roller-Gear Drive, but it had higher friction and lower efficiency (particularly at low power throughput levels). Use of full preloading rather than a variable preload system in the Differential Roller Drive assessed a heavy penalty in part load efficiency. Maximum measured efficiency (ratio of power out to power in) was 95% for the Differential Roller-Gear Drive and 86% for the Differential Roller Drive. The Momentum Balanced (Grounded Ring) Drive performed as expected kinematically. Reduction r-atios to the two counterrotating outputs (design nominal=24:1) were measured to be 23.98:1 and 24.12:1 at zero load.. At 25ONm (2200 in-lbf) output torque the ratio changed 2% due to roller creep. This drive was the smoothest of all three as determined from linearity and cogging tests, and maximum measured efficiency (ratio of power out to power in) was 95%. The disadvantages of full preloading as comvared to variable preload were apparent in this drive as in the Differential Roller Drive. Efficiencies at part load were low, but improved dramatically with increases in torque. These were consistent with friction measurements which indicated losses primarily from Coulomb friction. The initial preload level setting was low so roller slip was encountered at higher torques during testing.

Anderson, William J.↗

Room Temperature Quasi-static Characterization and Constitutive Model Parametrization of Flexible Polyurethane Foams of Different Densities Loaded in Different Orientations

This report describes the efforts to characterize and model General Plastics TF6070 and EF4000 flexible polyurethane foams under room temperature, large deformation quasi-static cyclic mechanical loading conditions. Densities from three to fifteen pound per cubic foot (PCF) are examined, which correspond to relative densities of approximately 4 to 20%. These foams are open cell structured and flexible at room temperature with a glass transition transition less than -30°C, and they fully recover their original shape when unloaded (at room temperature). Uniaxial compression tests were conducted with accompanying lateral image series for Digital Image Correlation (DIC) analysis with the goal of extracting transverse strain responses. Due to difficulties with DIC analysis at large strains, lateral strains were instead extracted for each test via edge tracking. The experimental results exhibit a nonlinear elastic response and anisotropic material behavior (particularly for the lower densities). Some hysteresis is observed that is different between the first and subsequent cycles of deformation indicating both a small degree of permanent damage (reduced stiffness during reloading) and viscoelasticity. These inelastic mechanisms are not considered in the modeling and calibration in this report. This work considers only the rate independent, room temperature foam behavior. Individual foam densities were calibrated for loading in two directions, parallel and perpendicular to the foam bubble rise direction, since the mechanical behavior is different in these two directions. The Flex Foam constitutive model was used for all parameterizations despite the fact that the model is isotropic. A review of the constitutive model is given as well as necessary data reduction procedures to parameterize it for each foam density and orientation are discussed. Finally, two different parameterizations are developed that take the undeformed foam density as an input that span all densities considered. These two parameterized models represent foams loaded in the rise and transverse directions respectively. We summarize the assumptions and limitations of the parameterizations provided in this report to guide analysis choices with them. All parameterizations presented herein have the following traits, room temperature, rate independent, damage-free, and non-dissipative . Isotropy (even if they are representing anisotropic data). Supplied Sierra Solid Mechanics Flex Foam Model Inputs are in units: pounds, inches, Celsius, and seconds

36 MATERIALS SCIENCE↗

Open Water Blade Strain Measurements on a Vertical-Axis Tidal Turbine

Open-water testing of marine renewable energy devices represents a significant milestone and hurdle for research teams and companies that seek to reduce the levelized cost of energy to allow these devices to compete in the open electrical generation market. For open-water testing of tidal energy converters (TECs), accurate measurements of loading characteristics on the blades and other structural components correlated with power performance metrics can be invaluable to further refine design principles and models, allowing continued improvement and cost reductions of new turbine designs. This paper will describe the modifications and additions made to a TEC system to achieve time-correlated blade strain measurements during full turbine operation along with a discussion on the overall impacts the required modifications had on the unmodified turbine.

mechanical loads↗

Reducing microgrid availability to reduce costs for coastal Puerto Rican communities

Renewable microgrids are sustainable, resilient solutions to mitigate and adapt to climate change. Making electric loads nearly 100% available (i.e., power remains on) during outages increases cost. Near 100% availability is required when human life or high-cost assets are involved, but availability can be reduced for less consequential loads leading to lower costs. This study analyses costs for photo-voltaic and lithium-ion battery microgrids with availability ranging from 0–99%. We develop a methodology to analyse three Puerto Rican coastal communities. Here, we consider power outage effects for hurricanes, earthquakes, and everyday outages. The results show cost versus availability from 0–99%. There is 27–31% cost reduction at 80% availability in comparison to 99% availability. A regression model of microgrid availability versus three ratios: 1) the annual generation to demand ratio, 2) storage to interruption energy ratio, and 3) peak storage to load ratio produced a coefficient of determination of 0.99949 with 70% of the data used for training and 30% for testing. The results can therefore be extended to other coastal Puerto Rican communities of varying sizes that have ratios within the ranges analysed in this study. This can empower decision makers to rapidly analyse designs that have availabilities well below 100%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental evaluation of 150-millimeter bore ball bearing to 3 million DN using either solid or drilled balls

Seven 150-mm bore ball bearings were run under 8900 Newton (2000 lb) thrust load at speeds from 6670 to 20,000 rpm (1 to 3 million DN). Four of the bearings had conventional solid balls and three bearing had drilled (cylindrically hollow) balls with 50 percent mass reduction. The bearings were under-race cooled and slot-lubricated with Type 2 ester oil at flow rates from 4.35 to 5.80 liters per minute (1.15 to 1.57 gal min). Friction torque and temperatures were measured on all bearings. No significant difference in torque was noted, between the solid and drilled ball bearings. One bearing of each type was rerun at 17,800 Newtons (4000 lb) thrust load. The solid ball bearings performed satisfactorily at 3 million DN. However, at about 2 million DN the drilled ball bearing experienced a broken ball and cracks appeared in two other balls as the result of flexure fatigue. Metallurgical examination of the cracked balls indicated a brittle structure in the bore of the drilled balls.

Scibbe, H. W.↗

Two-Stage Deep Reinforcement Learning for Distribution System Voltage Regulation and Peak Load Management

The growing integration of distributed solar photovoltaic (PV) in distribution systems could result in adverse effects during grid operation. This paper develops a two-agent soft actor critic-based deep reinforcement learning (SAC-DRL) solution to simultaneously control PV inverters and battery energy storage systems for voltage regulation and peak demand reduction. The novel two-stage framework, featured with two different control agents, is applied for daytime and nighttime operations to enhance control performance. Comparison results with other control methods on a real feeder in Western Colorado demonstrate that the proposed method can provide advanced voltage regulation with modest active power curtailment and reduce peak load demand from feeder's head.

deep reinforcement learning↗

Experimental Investigation of Air-Fuel Equivalence Ratio Effects on Advanced Dual-fuel Diesel/Ammonia Combustion on a Single-Cylinder Medium-Duty Diesel Engine at High Load

Ammonia (NH3) has gathered a lot of interest as a low-lifecycle-carbon fuel in sectors with high weight and distance requirements, such as shipping. The International Maritime Organization (IMO) mandates a 70-80% greenhouse gas (GHG) reduction by 2040, which is only possible with advanced engine technologies and fuels like NH3. Prior research studies at the US Department of Energy’s Oak Ridge National Laboratory have shown strong performance with NH3 under dual-fuel mode using conventional diesel combustion (CDC) manifold air pressure (MAP) settings. Diesel airflow was initially used to simplify retrofitting (no turbocharger modification), which resulted in air-fuel equivalence ratios (λ) greater than 1.5. To characterize potential improvements in dual-fuel NH3 combustion performance at richer in-cylinder conditions, a global λ sweep using a diesel pilot ignition (DPI) strategy with diesel fuel injected near top-dead center (TDC) and a reactivity-controlled compression ignition (RCCI) injection strategy with diesel fuel injected earlier during the compression stroke were compared. The experiments were conducted at 1200 RPM and 12.6 bar (75% load), and λ was varied by decreasing the commanded air flow to the engine at greater than 90% ammonia energy substitution (AES) level. A diesel injection timing sweep was conducted for both the combustion modes at fixed λ, and the timing with the lowest engine-out N2O emissions was identified. The results indicated an optimal balance between CO2, eq and thermal efficiency benefits for both DPI and RCCI injection strategy cases compared to CDC at a λ of 1.4. The indicated N-based emissions exhibited a strong correlation to the ratio of CA5–50 and ignition delay for DPI, but no apparent trend emerged for the RCCI injection strategy at the tested boundary conditions.

Tyrewala, Daanish [ORNL] (ORCID:0000000208599324)↗

The Role of Adaptation in Body Load-Regulating Mechanisms During Locomotion

Body loading is a fundamental parameter that modulates motor output during locomotion, and is especially important for controlling the generation of stepping patterns, dynamic balance, and termination of locomotion. Load receptors that regulate and control posture and stance in locomotion include the Golgi tendon organs and muscle spindles at the hip, knee, and ankle joints, and the Ruffini endings and the Pacinian corpuscles in the soles of the feet. Increased body weight support (BWS) during locomotion results in an immediate reorganization of locomotor control, such as a reduction in stance and double support duration and decreased hip, ankle, and knee angles during the gait cycle. Previous studies on the effect during exposure to increased BWS while walking showed a reduction in lower limb joint angles and gait cycle timing that represents a reorganization of locomotor control. Until now, no studies have investigated how locomotor control responds after a period of exposure to adaptive modification in the body load sensing system. The goal of this research was to determine the adaptive properties of body load-regulating mechanisms in locomotor control during locomotion. We hypothesized that body load-regulating mechanisms contribute to locomotor control, and adaptive changes in these load-regulating mechanisms require reorganization to maintain forward locomotion. Head-torso coordination, lower limb movement patterns, and gait cycle timing were evaluated before and after a 30-minute adaptation session during which subjects walked on a treadmill at 5.4 km/hr with 40% body weight support (BWS). Before and after the adaptation period, head-torso and lower limb 3D kinematic data were obtained while performing a goal directed task during locomotion with 0% BWS using a video-based motion analysis system, and gait cycle timing parameters were collected by foot switches positioned under the heel and toe of the subjects shoes. Subjects showed adaptive modification in the body load-regulating mechanisms that included increased head movement amplitude, increased knee and ankle flexion, and increased stance, stride, and double support time, with no change in the performance of the task with respect to that measured before exposure to BWS. These changes in locomotor control are opposite to that reported during 40% BWS exposure and indicative of an after-effect after removal of the adaptive stimulus. Therefore, it is evident that just 30 minutes of 40% BWS during locomotion was sufficient to induce adaptive modifications in the body load sensing systems that contribute to reorganization of sensory contributions to stable locomotor control.

Ruttley, Tara↗

Electronic structure of reduced CeO 2 (111) surfaces interacting with hydrogen as revealed through electron energy loss spectroscopy in comparison with theoretical investigations

Based on both, ab-initio cluster calculations as well as periodic density functional based loss function calculations, we have assigned the origins of the valence electron excitation regime in electron energy loss spectra of well-ordered ceria films in (111) orientation at various states of reduction as well as after exposing the reduced films to hydrogen from the gas phase (Li et al, Angew. Chem. Int. Ed., 58 (2019) 14686–14693). The explicit calculation of intensity distributions using the dipole approximation allow us to draw conclusions about the nature of oxygen vacancies, which occur upon reduction and how those interact with hydrogen to form hydride species. Herein, we also reports a brief discussion of vibrational excitations of hydrogen loaded ceria and corroborates previous interpretations, based on inelastic neutron scattering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of precooling unit design options in hydrogen refueling station for heavy-duty fuel-cell electric vehicles

Precooling gaseous hydrogen fuel to a cold temperature before refueling a heavy-duty (HD) hydrogen fuel cell electric vehicle (HFCEV) is essential to avoid overheating the vehicle tank, as well as achieving a high state of charge (SOC). Because a large volume of hydrogen is dispensed during each fill, the need for a shorter fill time amplifies the need to precool each load for refueling a HFCEV. Thus, the design and operation of a precooling unit (PCU), as well as the associated capital and operating costs, plays a pivotal role in any plans for heavy-duty hydrogen refueling stations. Here, in this paper, we present a thermodynamic and technoeconomic analysis of a PCU in a gaseous hydrogen refueling station (HRS) for HD HFCEVs. By employing Argonne National Laboratory's hydrogen station cost optimization and performance evaluation (H2SCOPE) model, the refueling of 50 kg of hydrogen on-board type IV tank at ambient temperatures of 15–45 °C and varying fill rates is simulated. The required degree of precooling temperature to obtain either 100% or the maximum possible SOC is obtained from the simulation. Additionally, the simulation results demonstrate that the average flow rate of hydrogen is approximately 40% lower than the maximum flow rate during a typical fill; which motivates further evaluation of the instantaneous hydrogen mass flow rate profile and suggests the scope of improving precooling unit design. Accordingly, a hybrid strategy of precooling hydrogen has been proposed to address the cooling load by sizing the refrigeration unit for the average flow rate of hydrogen, while supplementing the above average peak hydrogen flow cooling load through thermal buffering. The combined technique enables the downsizing of the original PCU capacity by 25–40% and demonstrates a potential cost reduction of the PCU by approximately 30%, which translates to an installed cost reduction of ∼$125,000 per dispenser.

25 ENERGY STORAGE↗

Integrated hydrogeophysical modelling and data assimilation for geoelectrical leak detection

Time-lapse electrical resistivity tomography (ERT) measurements provide indirect observations of hydrological processes in the Earth's shallow subsurface at high spatial and temporal resolution. ERT has been used in the past decades to detect leaks and monitor the evolution of associated contaminant plumes. Specifically, inverted resistivity images allow visualization of the dynamic changes in the structure of the plume. However, existing methods do not allow the direct estimation of leak parameters (e.g. leak rate, location, etc.) and their uncertainties. We propose an ensemble-based data assimilation framework that evaluates proposed hydrological models against observed time-lapse ERT measurements without directly inverting for the resistivities. Each proposed hydrological model is run through the parallel coupled hydro-geophysical simulation code PFLOTRAN-E4D to obtain simulated ERT measurements. The ensemble of model proposals is then updated using an iterative ensemble smoother. In this paper, we demonstrate the proposed framework on synthetic and field ERT data from controlled tracer injection experiments. Our results show that the approach allows joint identification of contaminant source location, initial release time, and solute loading from the cross-borehole time-lapse ERT data, alongside with an assessment of uncertainties in these estimates. We demonstrate a reduction in site-wide uncertainty by comparing the prior and posterior plume mass discharges at a selected image plane. This framework is particularly attractive to sites that have previously undergone extensive geological investigation (e.g., nuclear sites). It is well suited to complement ERT imaging and we discuss practical issues in its application to field problems.

58 GEOSCIENCES↗

Investigation of the Microstructure and Rheology of Iridium Oxide Catalyst Inks for Low-Temperature Polymer Electrolyte Membrane Water Electrolyzers

Here, we present an investigation of the structure and rheological behavior of catalyst inks for low-temperature polymer electrolyte membrane water electrolyzers. The ink consists of iridium oxide (IrO 2 ) catalyst particles and a Nafion ionomer dispersed in a mixture of 1-propanol and water. The effects of ionomer concentration and catalyst concentration on the microstructure of the catalyst ink were studied. Studies on dilute inks (0.1 wt % IrO 2 ) using zeta potential and dynamic light scattering measurements indicated a strong adsorption of the ionomer onto the catalyst particles which resulted in an increase in the ..zeta..-potential and the z-average diameter. Steady-shear and dynamic-oscillatory-shear rheological measurements of concentrated IrO 2 dispersions (35 wt % IrO 2 ) indicated that the particles are strongly agglomerated in the absence of the ionomer. The addition of even a small amount of the ionomer (2.4 wt % with respect to total solids) caused the rheology to transition from shear thinning to Newtonian because of the reduction in agglomerated structure due to stabilization of the aggregates by the ionomer, consistent with the behavior of dilute inks. At intermediate ionomer loadings, between 2.4 and 9 wt %, the viscosity increased with increasing ionomer wt %, though remained Newtonian, predominantly due to the increasing ionomer volume fraction in the ink. For ionomer loadings greater than 9 wt %, the particles were found to be flocculated, likely induced by a dispersed ionomer. The flocculated inks exhibited strong shear-thinning and gel-like behaviors in steady-shear and oscillatory-shear rheology. The onset of flocculation was found to be sensitive to the catalyst concentration, where below 35 wt % of IrO 2 , flocculation was not observed. The rheological observations were further verified by ultra-small-angle X-ray scattering.

36 MATERIALS SCIENCE↗