Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Investigation of the tip clearance flow inside and at the exit of a compressor rotor passage. II - Turbulence properties

The flow in the tip clearance region of a compressor rotor is highly turbulent due to the strong interaction of the leakage flow with the annulus wall boundary layer. This paper deals with the turbulence properties of the flow in the tip clearance region of a moderately loaded compressor rotor. The experimental results reported in this paper were obtained using a two-sensor hot-wire probe in combination with an ensemble averaging technique. Blade-to-blade distribution of the axial and tangential turbulence intensities at various radial locations and ten axial locations (four inside the blade passage and the remaining six outside the passage) were derived from this data. Isointensity contours in the clearance region at various radial locations were also obtained from the experimental data. A region of very high turbulence intensities was indicated at the half-chord location from these results. The turbulence intensity profiles also indicated that the leakage flow travels toward the midpassage before rolling up. The turbulence is almost isotropic beyond three-quarter chord downstream of the trailing edge.

Pandya, A.↗

A Two-Step Load Disaggregation Algorithm for Quasi-static Time-series Analysis on Actual Distribution Feeders

This paper focuses on developing a two-step load disaggregation method for conducting quasi-static time-series analysis using actual distribution feeder data. This can help utilities conduct power flow studies using smart meter measurements to assess the impact of high penetration of distributed energy resources. In the first step, load profiles of residential and commercial buildings obtained from smart meter data are used to match the load profile at the feeder head. This step will determine the number of residential and commercial loads on the feeder. The second step is to allocate the selected load profiles to each load node based on its transformer rating. This allows each load node to have its own load profile and the aggregation of those nodal load profiles matches closely to the metered feeder load shape at the substation. This algorithm is validated using smart meter data and the SCADA data of a real feeder. We compared the performance of the proposed method with the traditional load allocation method (i.e. use the feeder load shape for all subsequent load nodes scaling by the transformer capacities) when conducting quasi-static power flow studies. Results show that the proposed algorithm matches the utility data well and the obtained voltage profiles reveal more voltage dynamics than using the conventional load allocation method. (PDF) A Two-Step Load Disaggregation Algorithm for Quasi-static Time-series Analysis on Actual Distribution Feeders.

load disaggregation, load shape, quasi-static, tim↗

The effect of circumferential distortion on fan performance at two levels of blade loading

Single stage fans designed for two levels of pressure ratio or blade loading (rotor tip D-factor of 0.43 and 0.54) were subjected to screen-induced circumferential distortions of 90-degree extent. Both fan rotors were designed for a blade tip speed of 425 m/sec, blade solidity of 1.3 and a hub-to-tip radius ratio of 0.5. Circumferential measurements of total pressure, temperature, static pressure, and flow angle were obtained at the hub, mean and tip radii at five axial stations (three between the screen and rotor and behind rotor and stator blade rows). Rotor loading level did not appear to have a significant influence on rotor response to distorted flow. Losses in overall pressure ratio due to distortion were most severe in the stator hub region of the more highly loaded stage. At the near stall operating condition tip and hub regions of (either) rotor demonstrated different response characteristics to the distorted flow. No effect of loading was apparent on interactions between rotor and upstream distorted flow fields.

Hartmann, M. J.↗

Structural Analysis Findings of Open Spelter Socket Cable Terminations

A three-dimensional nonlinear finite element model of a representative open spelter socket termination was developed to examine the underlying mechanics of load transfer from a structural cable through the termination, the sensitivity of the joint design to wire brooming, zinc material nonlinearity, contact friction between the zinc and socket, voids within the zinc, and, finally, the effects of repeated loading on the joint. Primary factors affecting open spelter socket design are cast zinc plastic flow, depth of zinc slug seating, and quality of wire brooming. Zinc plasticity and proper brooming allows for efficient load transfer by developing confining pressure on the broomed wires in the narrow part of the socket, which keep the wires from pulling out of the zinc and shift failure to occur outside the socket. Highest wire stresses in the cable occur in the outer ring adjacent to the termination. While industry use of stay cables are typically designed to carry less than half the rated breaking force in aggregate, the constituent stresses within the zinc and the wires have the potential to exceed their respective allowable in operation and should be evaluated for fatigue- and creep-critical applications.

Pavel Babuska↗

Optimization of a Centrifugal Impeller Design Through CFD Analysis

This paper discusses the procedure, approach and Rocketdyne CFD results for the optimization of the NASA consortium impeller design. Two different approaches have been investigated. The first one is to use a tandem blade arrangement, the main impeller blade is split into two separate rows with the second blade row offset circumferentially with respect to the first row. The second approach is to control the high losses related to secondary flows within the impeller passage. Many key parameters have been identified and each consortium team member involved will optimize a specific parameter using 3-D CFD analysis. Rocketdyne has provided a series of CFD grids for the consortium team members. SECA will complete the tandem blade study, SRA will study the effect of the splitter blade solidity change, NASA LeRC will evaluate the effect of circumferential position of the splitter blade, VPI will work on the hub to shroud blade loading distribution, NASA Ames will examine the impeller discharge leakage flow impacts and Rocketdyne will continue to work on the meridional contour and the blade leading to trailing edge work distribution. This paper will also present Rocketdyne results from the tandem blade study and from the blade loading distribution study. It is the ultimate goal of this consortium team to integrate the available CFD analysis to design an advanced technology impeller that is suitable for use in the NASA Space Transportation Main Engine (STME) fuel turbopump.

Chen, W. C.↗

Load Shed Recovery With Transmission Switching and Intentional Islanding Methods After (N-2) Line Contingencies

Changing power system configuration may result in load shed recovery (LSR) because topology change can provide power flow control in meshed network. Some topologies may favor generation redispatch as compared to others and can eliminate line congestion which leads to LSR. One of the known methods for topology change is called transmission switching (TS) and research conducted in the past showed that TS is an effective means of mitigating load shedding. Another method of topology control is intentional islanding (IIS). In this manuscript, we explore IIS as a potential solution for LSR. IIS based on generator coherency has been presented in literature for mitigating cascading failures. However, IIS has not been explored solely as a LSR mechanism. In this paper, we compare the LSR based on IIS with well known LSR algorithm based on TS. The comparison is performed for IEEE 39-bus system and IEEE 118- bus system. The results show that IIS has a potential to perform better than TS in terms of computational efficiency and LSR.

42 ENGINEERING↗

Characterization of self-magnetic pinch radiographic diode performance on RITS-6 at Sandia National Laboratories. II. Coupling between the inductive voltage adder and the SMP load

The self-magnetic pinch (SMP) diode is a type of radiographic diode used to generate an intense electron beam for radiographic applications. At Sandia National Laboratories, SMP was the diode load for the six-cavity radiographic integrated test stand inductive voltage adder (IVA) driver operated in a magnetically insulated transmission line (MITL). The MITL contributes a flow current in addition to the current generated within the diode itself. Extensive experiments with a MITL of 40Ω load impedance [T. J. Renk et al., Phys. Plasmas 29, 023105 (2022)] indicate that the additional flow current leads to results similar to what might be expected from a conventional high-voltage interface driver, where flow current is not present. However, when the MITL flow impedance was increased to 80 Ω, qualitatively different diode behavior was observed. This includes large retrapping waves suggestive of an initial coupling to low impedance as well as diode current decreasing with time even as the total current does not. A key observation is that the driver generates total current (flow + diode) consistent with the flow impedance of the MITL used. The case is made in this paper that the 80Ω MITL experiments detailed here can only be understood when the IVA-MITL-SMP diode is considered as a total system. Additionally, the constraint of fixed total current plus the relatively high flow impedance limits the ability of the diode (whether SMP or other type) to act as an independent load. An unexpected new result is that in tracking the behavior of the electron strike angle on the converter as a function of time, we observed that the conventional cIV x “Radiographic” radiation scaling (where x~2.2) begins to break down for voltages above 8 MV, and cubic scaling is required to recover accurate angle tracking.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources: Preprint

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

61 RADIATION PROTECTION AND DOSIMETRY↗

Flow strength of tantalum under ramp compression to 250 GPa

A magnetic loading technique was used to study the strength of polycrystalline tantalum ramp compressed to peak stresses between 60 and 250 GPa. Velocimetry was used to monitor the planar ramp compression and release of various tantalum samples. A wave profile analysis was then employed to determine the pressure-dependence of the average shear stress upon unloading at strain rates on the order of 10{sup 5} s{sup −1}. Experimental uncertainties were quantified using a Monte Carlo approach, where values of 5% in the estimated pressure and 9–17% in the shear stress were calculated. The measured deviatoric response was found to be in good agreement with existing lower pressure strength data as well as several strength models. Significant deviations between the experiments and models, however, were observed at higher pressures where shear stresses of up to 5 GPa were measured. Additionally, these data suggest a significant effect of the initial material processing on the high pressure strength. Heavily worked or sputtered samples were found to support up to a 30% higher shear stress upon release than an annealed material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of turbulence and thermophysical fluid properties on cavitation erosion predictions in channel flow geometries

Cavitation and cavitation-induced erosion have been observed in fuel injectors in regions of high acceleration and low pressure. Although these phenomena can have a large influence on the performance and lifetime of injector hardware, questions still remain on how these physics should be accurately and efficiently represented within a computational fluid dynamics model. While several studies have focused on the validation of cavitation predictions within canonical and realistic injector geometries, it is not well documented what influence the numerical and physical parameters selected to represent turbulence and phase change will have on the predictions for cavitation erosion propensity and severity. In this work, a range of numerical and physical parameters are evaluated within the mixture modeling approach in CONVERGE to understand their influence on predictions of cavitation, condensation and erosion. Particular attention is paid to grid resolution, turbulence model and near-wall treatment, fuel surrogate properties, and non-condensable gas content. Assessment of cavitation predictions are conducted through comparison of measured and predicted mass flow rates and cavitation probability distributions for flow through a channel with a sharp inlet. Predictions for hydrodynamic impact loading and cavitation erosion are compared with the experimentally measured incubation period and critical site for erosion. Based on these findings, recommendations are provided for modeling turbulent cavitating flows, using the single fluid mixture modeling approach, to improve predictions for cavitation-induced erosion. In particular, to capture the fluid dynamic phenomena characterizing cavitation cloud formation, development and shedding, a Large Eddy simulation with grid resolution as fine as 2.50 μm is recommended. The assumed concentration of non-condensable gas content is observed to have a strong influence on the predicted cavitation erosion severity, which motivates the need for dissolved gas concentration measurements for future cavitation erosion experimental studies. Using the best practices established in this work, good agreement is achieved between the measured and predicted cavitation parameters, as well as the critical site for cavitation-induced erosion.

Magnotti, Gina Maureen↗

A study of forced flow separation in rocket nozzle

The characteristics of flow profile in a rocket nozzle during the start transient were investigated as well as possibilities of reducing the side-load thrust by sticking trip wires in the nozzle. To simplify the geometry of flow configuration around the trip wire, it was assumed that the flow is passing through square steps instead of round wires. Since a purely analytic solution is not available, a series of semiempirical solutions was proposed.

Chiou, J. N.↗

Further Investigations of Control Surface Seals for the X-38 Re-Entry Vehicle

NASA is currently developing the X-38 vehicle that will be used to demonstrate the technologies required for a potential crew return vehicle (CRV) for the International Space Station. This vehicle would serve both as an ambulance for medical emergencies and as an evacuation vehicle for the Space Station. Control surfaces on the X-38 (body flaps and rudder/fin assemblies) require high temperature seals to limit hot gas ingestion and transfer of heat to underlying low-temperature structures to prevent over-temperature of these structures and possible loss of the vehicle. NASAs Johnson Space Center (JSC) and Glenn Research Center (GRC) are working together to develop and evaluate seals for these control surfaces. This paper presents results for compression. flow, scrub, and arc jet tests conducted on the baseline X-38 rudder/fin seal design. Room temperature seal compression tests were performed at low compression levels to determine load versus linear compression, preload. contact area, stiffness. and resiliency characteristics under low load conditions. For all compression levels that were tested, unit loads and contact pressures for the seals were below the 5 lb/in. and 10 psi limits required to limit the loads on the adjoining Shuttle thermal tiles that the seals will contact. Flow rates through an unloaded (i.e. 0% compression) double arrangement were twice those of a double seal compressed to the 20% design compression level. The seals survived an ambient temperature 1000 cycle scrub test over relatively rough Shuttle tile surfaces. The seals were able to disengage and re-engage the edges of the rub surface tiles while being scrubbed over them. Arc jet tests were performed to experimentally determine anticipated seal temperatures for representative flow boundary conditions (pressures and temperatures) under simulated vehicle re-entry conditions. Installation of a single seat in the gap of the test fixture caused a large temperature drop (1710 F) across the seal location as compared to an open gap condition (140 F) confirming the need for seals in the rudder/fin gap location. The seal acted as an effective thermal barrier limiting heat convection through the seal gap and minimizing temperature increases downstream of the seal during maximum heating conditions.

Dunlap, Patrick H., Jr.↗

Comparative Analysis of HEATNETS for Geothermal Network Performance: Preprint

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer, rather than also comparing control systems responses. HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study shows that HEATNETS, while not intended to replace other modeling tools, can be a unique modeling tool for the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Enabling Secure Scalable Microgrids with High Penetration Renewables

Laboratory Directed Research and Design (LDRD) originating technologies are being developed to address challenges inherent to highly stochastic energy sources and loads, to conceivably satisfy the electrical energy needs of national/international power systems. The Enabling Secure, Scalable Microgrids with High Penetration Renewables Grand Challenge LDRD (FY11-FY13) aimed to develop a novel intelligent grid architecture, Secure Scalable Microgrid (SSM), based on closed loop controls and an agent-based architecture supporting intelligent power flow control. The approach was to enable self-healing, self-adapting, self-organizing architectures and allow a trade-off between storage in the grid versus information flow to control generation sources, power distribution, and where necessary, loads. L

24 POWER TRANSMISSION AND DISTRIBUTION↗

Forced flow cooling of high field, REBCO-based, fusion magnets using supercritical hydrogen, helium, and neon

Rare Earth Barium Copper Oxide (REBCO) High Temperature Superconductor (HTS) tapes are being considered for the Toroidal Field (TF) magnets of a highly compact, high field fusion reactor operating at magnetic fields as high as 21 T and operating temperatures in the range of 10–30 K. Due to the increase in range of operating conditions made available through HTS tapes, a new set of cryogenic fluids are being considered for forced flow cooling. The present study investigates helium, hydrogen, and neon as a forced flow coolant for REBCO HTS tapes used in a highly compact, high-field reactor design. Four design criteria are considered, including current sharing temperature, fluid inlet temperature, cable pressure drop (dP), and operating pressure. From these simulations, neon is removed from consideration due to its high required pressure drop and low temperature margins with respect to the current sharing limit. Helium and hydrogen are then compared, with hydrogen producing the highest overall heat transfer rate at its optimum operating condition (1.5 MPa/15 K). A compromise across inlet temperature, dP, and operating pressure is found when helium has a minimum initial temperature of 10 K and an inlet pressure of 2.0 MPa. For the current design, helium is selected as a coolant due its acceptable cable pressure drop, required cooling load, and system complexity inherent to a forced-flow cryogenic system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of processing defects on the dynamic tensile mechanical behavior of laser-solid-formed Ti-6Al-4 V

Highlights: • Tensile tests are conducted under coupled effects of strain rate and temperature. • Defects act as crack initiation and propagation sites for dynamic tensile fracture. • Dynamic tension-compression asymmetry is due to different behaviors of defects. • Different deformation of defects results in tensile mechanical anisotropy. • Mechanical anisotropy and asymmetry are sensitive to strain rate and temperature. - Abstract: The initial processing defects, i.e. voids, lack-of-fusion pores and inclusions, are the inevitable and unique microstructural features in the Ti-6Al-4 V (Ti64) alloy manufactured by laser solid forming (LSF). This study was to gain insight into the influences of these processing defects on the tensile thermomechanical response of the material under various strain rates of 0.001/s, 500/s, 1000/s and 3000/s, and under a wide range of temperatures from 298 K to 1273 K. The drastic effects of processing defects on the flow stress were founded to be susceptible to tensile loading and increase with the increasing strain rate. The SEM analysis was carried out to further understand the effect of initial processing defects on the dynamic fracture behavior. These processing defects, such as voids and lack-of-fusion pores, are the most vulnerable position to release impact energy instantaneously and then evolve into the initiation site and propagation path for dynamic tensile crack. The tensile crack under high strain rate and high temperature propagates through the columnar prior-β grain boundary α colony. It was analyzed that the typical tension-compression asymmetry in strength is positively associated with the strain rate in the Ti64 alloy by LSF. Such asymmetry is due to the differences in the deformation mechanism of processing defects and in the activated slip system under tensile and compressive loading. Additionally, the anisotropy of the mechanical property was discussed by examining the positive strain rate effects in two orientations (i.e., perpendicular and parallel to the crystal growth direction). This anisotropy is caused by different mechanical behaviors of lack-of-fusion defects and β grain boundary α colony in different orientations.

36 MATERIALS SCIENCE↗

Potential flow applications to complex configurations

Recent advances in CFD methods have enabled the analytic calculation of the carriage loads for stores mounted on complex aircraft. The latest results have demonstrated excellent agreement with test data for the F-15 at M = 0.98. However, in a preliminary design environment, the necessity of generating and validating a Euler grid to fit the aircraft and store arrangement may not be feasible, particularly when effects of configuration changes are considered. For that reason alternative approaches which require less time to arrive at an answer deserve consideration. The paper presents the results of a study to determine if potential flow solutions can give acceptable estimates of store carriage loads at transonic speeds in a timely manner.

Cenko, A.↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗