Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Frequency domain analysis of the random loading of cracked panels

The primary effort concerned the development of analytical methods for the accurate prediction of the effect of random loading on a panel with a crack. Of particular concern was the influence of frequency on the stress intensity factor behavior. Many modern structures, such as those found in advanced aircraft, are lightweight and susceptible to critical vibrations, and consequently dynamic response plays a very important role in their analysis. The presence of flaws and cracks can have catastrophic consequences. The stress intensity factor, K, emerges as a very significant parameter that characterizes the crack behavior. In analyzing the dynamic response of panels that contain cracks, the finite element method is used, but because this type of problem is inherently computationally intensive, a number of ways of calculating K more efficiently are explored.

Doyle, James F.↗

Interleukin-2 therapy reverses some immunosuppressive effects of skeletal unloading

Using antiorthostatic suspension, we characterized hematopoietic changes that may be responsible for the detrimental effect of skeletal unloading on macrophage development. Skeletally unloaded mice had suppressed macrophage development in unloaded and loaded bones, which indicated a systemic effect. Bone marrow cells from unloaded mice secreted less macrophage colony-stimulating factor and interleukin-6 than control mice. Additionally, T-lymphocyte proliferation was reduced after skeletal unloading. We show that polyethylene glycol-interleukin-2 therapy reversed the effects of skeletal unloading on macrophage development and cell proliferation.

Armstrong, Jason W.↗

The Merging of Fatigue and Fracture Mechanics Concepts: A Historical Perspective

The seventh Jerry L. Swedlow Memorial Lecture presents a review of some of the technical developments, that have occurred during the past 40 years, which have led to the merger of fatigue and fracture mechanics concepts. This review is made from the viewpoint of 'crack propagation.' As methods to observe the 'fatigue' process have improved, the formation of fatigue micro-cracks have been observed earlier in life and the measured crack sizes have become smaller. These observations suggest that fatigue damage can now be characterized by 'crack size.' In parallel, the crack-growth analysis methods, using stress-intensity factors, have also improved. But the effects of material inhomogeneities, crack-fracture mechanisms, and nonlinear behavior must now be included in these analyses. The discovery of crack-closure mechanisms, such as plasticity, roughness, and oxide/corrosion/fretting product debris, and the use of the effective stress-intensity factor range, has provided an engineering tool to predict small- and large-crack-growth rate behavior under service loading, conditions. These mechanisms have also provided a rationale for developing, new, damage-tolerant materials. This review suggests that small-crack growth behavior should be viewed as typical behavior, whereas large-crack threshold behavior should be viewed as the anomaly. Small-crack theory has unified 'fatigue' and 'fracture mechanics' concepts; and has bridged the cap between safe-life and durability/damage-tolerance design concepts.

Newman, James C., Jr.↗

Stress Concentrations in Filamentary Structures

Theoretical analyses are made of the stress distributions in a sheet of parallel filaments which carry normal loads and are imbedded in a matrix which carries only shear. In all cases, uniform loading at infinity is assumed and small-deflection elasticity theory is used. Static and dynamic stress-concentration factors due to one or more filaments being broken are determined. Particular attention is paid the dynamic overshoot resulting when the filaments are suddenly broken. The dynamic-response factor increases from 1.15 to 1.27 as the number of broken filaments is increased from one to infinity. A somewhat lower dynamic-response factor is obtained when a hole is suddenly caused in the filament sheet.

Hedgepeth, John M.↗

Large Bandwidth and Low Noise in a Diffusion-Cooled Hot-Electron Bolometer Mixer

Heterodyne measurements have been made at 533 GHz using a novel superconducting hot-electron bolometer in a waveguide mixer. The bolometer is a 0.3 micrometer long niobium microbridge with a superconducting transition temperature of 5 K. The short length ensures that electron diffusion dominates over electron-phonon interactions as the electron cooling mechanism, which should allow heterodyne detection with intermediate frequencies (if) of several GHz. A Y-factor response of 1.15 dB has been obtained at an if of 1.4 GHz with 77 and 295 K loads, indicating a receiver noise temperature of 650 K DSB. The -3 dB rolloff in the if response occurs at 1.7 GHz.

Skalare, A.↗

SDBI 1904: Human Factors Assessment of Vibration Effects on Visual Performance during Launch

The primary objective of the of Human Factors Short Duration Bioastronautics Investigation (SDBI) 1904 is to determine visual performance limits during operational vibration and g-loads, specifically through the determination of minimal usable font sizes using Orion-type display formats. Currently there is little to no data available to quantify human visual performance under these extreme conditions. Existing data on shuttle vibration magnitude and frequency is incomplete, does not address seat and crew vibration in the current configuration, and does not address human visual performance. There have been anecdotal reports of performance decrements from shuttle crews, but no structured data has been collected. The SDBI is a companion effort to the Detailed Test Objective (DTO) 695, which will measure shuttle seat accelerations (vibration) during ascent. Data from the SDBI will serve an important role in interpreting the DTO vibration data. This data will be collected during the ascent phase of three shuttle missions (STS-119, 127, and 128). Both SDBI1904 and DTO 695 are low impact with respect to flight resources, and combined they represent an efficient and focused problem solving approach. The SDBI and DTO data will be correlated to determine the nature of perceived visual performance under varying vibrations and g-loads. This project will provide: * Immediate data for developing preliminary human performance vibration requirements * Flight validated inputs for ongoing and future ground-based research * Information of functional needs that will drive Orion display format design decisions

Shelby G Thompson↗

Human-in-the-Loop Evaluation of Dynamic Multi-Flight Common Route Advisories

Flights often experience large delays when they are routed around weather. Multi-flight common route advisories provide delay recovery by suggesting time-saving re-routes for groups of flights whose current weather-avoidance routes have become outdated because the weather has dissipated and/or moved away. A laboratory evaluation of these advisories was conducted by four subject matter experts having extensive experience in traffic flow management operations. These experts provided a total of 120 data points in the airspace of Houston Center. The multi-flight common route tool provides time-saving route change advisories taking into account flight plans, wind fields, and the spatio-temporal evolution of predicted convective weather. It is not designed to account for complex operational factors such as non-standard sector traversal and interactions with local traffic management initiatives; hence a relatively low percentage (37%) of advisories generated by the tool were rated as acceptable. However, a high percentage (81%) of advisories were rated as acceptable after the subject matter experts used the tool's user interface to make route modifications that accounted for relevant operational factors not considered by the tool. The workload associated with using the tool, as measured by the NASA Task Load Index, was quite low (1.1 on a scale of 0 to 10). The results of this evaluation make a good case for human-automation teaming to design operationally valid weather re-routes for delay recovery.

Traffic Flow Management↗

Human-in-the-Loop Evaluation of Dynamic Multi-Flight Common Route Advisories

Flights often experience large delays when they are routed around weather. Multi-flight common route advisories provide delay recovery by suggesting time-saving re-routes for groups of flights whose current weather-avoidance routes have become outdated because the weather has dissipated and/or moved away. A laboratory evaluation of these advisories was conducted by four subject matter experts having extensive experience in traffic flow management operations. These experts provided a total of 120 data points in the airspace of Houston Center. The multi-flight common route tool provides time-saving route change advisories taking into account flight plans, wind fields, and the spatio-temporal evolution of predicted convective weather. It is not designed to account for complex operational factors such as non-standard sector traversal and interactions with local traffic management initiatives; hence a relatively low percentage (37%) of advisories generated by the tool were rated as acceptable. However, a high percentage (81%) of advisories were rated as acceptable after the subject matter experts used the tool's user interface to make route modifications that accounted for relevant operational factors not considered by the tool. The workload associated with using the tool, as measured by the NASA Task Load Index, was quite low (1.1 on a scale of 0 to 10). The results of this evaluation make a good case for human-automation teaming to design operationally valid weather re-routes for delay recovery.

Traffic Flow Management↗

Large Bandwidth and Low Noise in a Diffusion-Cooled Hot-Electron Bolometer Mixer

X Heterodyne measurements have been made at 533 GHz using a novel superconducting hot-electron bolometer in a waveguide mixer. The bolometer is a 0.3 ??ong niobium microbridge with T c =(approx. equal to)5K. The short length ensures that electron diffusion dominates over electron-phonon interactions as the electron cooling mechanism, which should allow heterodyne detection with intermediate frequencies (if{italics})) of several GHz. A Y-factor response of 1.15dB has been obtained at an if(italics) of 1.4 GHz with 77k and 295k loads, indicating a receiver noise temperature of 650 k DSB. The -3 dB rolloff in the if(italics) response occurs at 1.7 GHz.

Heterodyne↗

Predicting Unreinforced Fabric Mechanical Behavior with Recurrent Neural Networks

Unreinforced woven fabrics are widely employed in various high-performance applications, including parachute deployment systems, airbags, and ballistic armor. The analysis of such materials is inherently complex due to the multiscale structure of these materials, and the dependence of macroscale behavior on changes that occur at lower scales. Previously, NASA’s Multiscale Analysis Tool (NASMAT) showed its capability in predicting unreinforced fabric behavior at the macroscale by capturing finite rotations that occur at the mesoscale. Though effective, the tool can face high computational cost for large, complex problems, motivating the need for the development of a surrogate model that can capture the same behavior. A recurrent neural network (RNN) was developed and trained on virtual NASMAT data to mimic the physics-based solutions while improving the computational runtime. The architecture of the RNN to best simulate the fabric behavior was carefully crafted based on heuristic knowledge of predicting physics-based temporal data, manual hyperparameter case studies, and Hyperband optimization.. The resultant model was able to predict a variety of stress-strain curves for fabrics with different mesoscale geometries, and was further validated by comparing to experimental data for the K706 style Kevlar plain-weave fabric, demonstrating the ability of the model to effectively capture the geometric changes in the fabric without explicitly calculating them, as is done in NASMAT. Furthermore, the tool showed its ability to improve on the runtime by a factor of 10 for fabric solutions compared to the multiscale tool, which would further enable the simulation of complex loading scenarios on unreinforced fabrics.

Fabric↗

Analysis of different operating strategies of thermal energy storage with radiant cooling system

Thermal energy storage systems in building cooling applications have been explored extensively as a peak load-shifting technology. Thermal energy storage performance has been recognized and studied from an energy cost-savings point of view because of peak-valley price differences, but not many studies have been conducted from an energy savings viewpoint. This study experimentally investigates the performance of the energy storage-retrofitted to a ceiling-type radiant cooling system. To study the performance, a water-based storage system was designed and developed for an academic office building equipped with a radiant cooling system. The water in the storage tank was cooled to a certain storage temperature in the nighttime, and the same water was used during the daytime for meeting the cooling load. Different combinations of charging and discharging schedules were analyzed. The key objective of the study was to achieve energy savings and energy-cost savings simultaneously. This objective was accomplished by identifying the major factors contributing to the energy consumption of the storage-retrofitted cooling system and devising novel operating strategies, leading to an enhanced energy savings potential. Two operating strategies comprising 24 operating scenarios were compared and the storage was used to dispatch the load for 3 hours of the day as a full storage unit. Results showed that in hot and dry climate conditions, using the storage with the radiant cooling system offered energy savings of 3% to 14%. The energy-cost analysis was also performed using a time-of-day electricity tariff plan. The energy-cost savings varied from 17.5% to 22.4% for these operating scenarios.

25 ENERGY STORAGE↗

Influence of biogenic emissions from boreal forests on aerosol–cloud interactions

Boreal forest acts as a carbon sink and contributes to the formation of secondary organic aerosols via emission of aerosol precursor compounds. However, these influences on the climate system are poorly quantified. Here we show direct observational evidence that aerosol emissions from the boreal forest biosphere influence warm cloud microphysics and cloud-aerosol interactions in a scale-dependent and highly dynamic manner. Analyses of in situ and ground-based remote-sensing observations from the SMEAR II station in Finland, conducted over eight months in 2014, reveal substantial increases in aerosol load over the forest one to three days after aerosol-poor marine air enters the forest environment. We find that these changes are consistent with secondary organic aerosol formation and, together with water-vapour emissions from evapotranspiration, are associated with changes in the radiative properties of warm, low-level clouds. Here, the feedbacks between boreal forest emissions and aerosol-cloud interactions and the highly dynamic nature of these interactions in air transported over the forest over timescales of several days suggest boreal forests have the potential to mitigate climate change on a continental scale. Our findings suggest that even small changes in aerosol precursor emissions, whether due to changing climatic or anthropogenic factors, may substantially modify the radiative properties of clouds in moderately polluted environments. Emissions from the boreal forest biosphere can substantially increase aerosol load above the forest and influence the radiative properties of clouds, according to analysis of observations from a monitoring station in Finland.

54 ENVIRONMENTAL SCIENCES↗

Advances in the analysis and design of adhesive-bonded joints in composite aerospace structures

Several aspects of adhesive-bonded joint analysis and design are presented from the reference of size of structure or load intensity. This integrates the individual characterizations of double-lap, single-lap, stepped-lap, tapered-lap and scarf joints. The paper includes an overview of bonded joint selection from the standpoints of design, fabrication, and processing, each bearing in mind the influence of such considerations on the strength of the joint. A case study is presented of the optimization of a specific relatively thick titanium-to-graphite epoxy stepped-lap joint, using the digital computer analysis program A4EG. The factors accounted for are adhesive plasticity, adherend stiffness imbalance, adherend thermal mismatch, and change of material properties within the range of temperature environment and with load direction. The strength increases obtainable by refining the initial design are demonstrated.

Hart-Smith, L. J.↗

A Method for Calculating Strain Energy Release Rates in Preliminary Design of Composite Skin/Stringer Debonding Under Multi-Axial Loading

Three simple procedures were developed to determine strain energy release rates, G, in composite skin/stringer specimens for various combinations of unaxial and biaxial (in-plane/out-of-plane) loading conditions. These procedures may be used for parametric design studies in such a way that only a few finite element computations will be necessary for a study of many load combinations. The results were compared with mixed mode strain energy release rates calculated directly from nonlinear two-dimensional plane-strain finite element analyses using the virtual crack closure technique. The first procedure involved solving three unknown parameters needed to determine the energy release rates. Good agreement was obtained when the external loads were used in the expression derived. This superposition technique was only applicable if the structure exhibits a linear load/deflection behavior. Consequently, a second technique was derived which was applicable in the case of nonlinear load/deformation behavior. The technique involved calculating six unknown parameters from a set of six simultaneous linear equations with data from six nonlinear analyses to determine the energy release rates. This procedure was not time efficient, and hence, less appealing. A third procedure was developed to calculate mixed mode energy release rates as a function of delamination lengths. This procedure required only one nonlinear finite element analysis of the specimen with a single delamination length to obtain a reference solution for the energy release rates and the scale factors. The delamination was extended in three separate linear models of the local area in the vicinity of the delamination subjected to unit loads to obtain the distribution of G with delamination lengths. This set of sub-problems was Although additional modeling effort is required to create the sub- models, this local technique is efficient for parametric studies.

Krueger, Ronald↗

What Is the Value of Alternative Methods for Estimating Ramping Needs?

Power system operators procure and deploy flexibility reserves or ramping products to address balancing needs caused by uncertainty and variability of load and generation. Existing methods estimate ramping needs using calendar information and historical forecast errors. Novel methods investigate if real-time weather information could inform ramping and other balancing requirements. This paper compares estimation methods for ramping requirements in theory and practice. The theoretical framework indicates when an alternative method could yield improved economic or reliability performance than existing methods by requiring lower or higher levels of ramping products. Preliminary simulations on a 118-bus test system for 4 days in May 2019 illustrate how system performance improves or deteriorates when ramping requirements are weather-informed (alternative) instead of calendar-based (baseline). Preliminary results suggest high variability in change of performance and underline the impact of additional factors, such as system conditions, on the realized performance change.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Effect of strain isolator pad modulus on inplane strain in Shuttle Orbiter thermal protection system tiles

The thermal protection system used on the Space Shuttle orbiter to determine strains in the reusable surface insulation tiles under simulated flight loads was investigated. The effects of changes in the strain isolator pad (SIP) moduli on the strains in the tile were evaluated. To analyze the SIP/tile system, it was necessary to conduct tests to determine inplane tension and compression modulus and inplane failure strain for the densified layer of the tiles. It is shown that densification of the LI-900 tile material increases the modulus by a factor of 6 to 10 and reduces the failure strain by about 50%. It is indicated that the inplane strain levels in the Shuttle tiles in the highly loaded regions are approximately 2 orders of magnitude lower than the failure strain of the material. It is concluded that most of the LI-900 tiles on the Shuttle could be mounted on a SIP with tensile and shear stiffnesses 10 times those of the present SIP without inplane strain failure in the tile.

Sawyer, J. W.↗

Unified aeroacoustics analysis for high speed turboprop aerodynamics and noise. Volume 3: Application of theory for blade loading, wakes, noise, and wing shielding

Results of the program for the generation of a computer prediction code for noise of advanced single rotation, turboprops (prop-fans) such as the SR3 model are presented. The code is based on a linearized theory developed at Hamilton Standard in which aerodynamics and acoustics are treated as a unified process. Both steady and unsteady blade loading are treated. Capabilities include prediction of steady airload distributions and associated aerodynamic performance, unsteady blade pressure response to gust interaction or blade vibration, noise fields associated with thickness and steady and unsteady loading, and wake velocity fields associated with steady loading. The code was developed on the Hamilton Standard IBM computer and has now been installed on the Cray XMP at NASA-Lewis. The work had its genesis in the frequency domain acoustic theory developed at Hamilton Standard in the late 1970s. It was found that the method used for near field noise predictions could be adapted as a lifting surface theory for aerodynamic work via the pressure potential technique that was used for both wings and ducted turbomachinery. In the first realization of the theory for propellers, the blade loading was represented in a quasi-vortex lattice form. This was upgraded to true lifting surface loading. Originally, it was believed that a purely linear approach for both aerodynamics and noise would be adequate. However, two sources of nonlinearity in the steady aerodynamics became apparent and were found to be a significant factor at takeoff conditions. The first is related to the fact that the steady axial induced velocity may be of the same order of magnitude as the flight speed and the second is the formation of leading edge vortices which increases lift and redistribute loading. Discovery and properties of prop-fan leading edge vortices were reported in two papers. The Unified AeroAcoustic Program (UAAP) capabilites are demonstrated and the theory verified by comparison with the predictions with data from tests at NASA-Lewis. Steady aerodyanmic performance, unsteady blade loading, wakes, noise, and wing and boundary layer shielding are examined.

Hanson, D. B.↗