Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Wave properties near the subsolar magnetopause - Pc 1 waves in the sheath transition layer

We study the waves in the frequency range of Pc 1 in the sheath transition layer of the magnetopause from the ISEE 1 and 2 observations. The waves are enhanced in the sheath transition layer, although they are scattered into the magnetosheath when the outer edge of the sheath transition layer is not sharp. The wave frequency is proportional to, and equal to, about 44 percent of the ion gyrofrequency. The waves are left-handed polarized for southward IMF, but linearly polarized for northward IMF. The direction of maximum variation is perpendicular to both the background field and the gradients of the field and density for northward IMF; for southward IMF, the waves are more turbulent. Wave generation mechanisms may depend on IMF orientations rather than the shock geometry. To investigate the free energy generating the waves for northward IMF, a method is developed combining the measurements from the fast plasma experiment and Lepedea to obtain a high time resolution estimate of the temperature anisotropy for strongly northward IMF. The estimated ion temperature anisotropy is enhanced, up to a factor of 2, within the sheath transition layer for northward IMF.

Song, P.↗

Controller Design for the ST7 Disturbance Reduction System

The Space Technology 7 experiment will perform an on-orbit system-level validation of two specific Disturbance Reduction System technologies: a gravitational reference sensor employing a free-floating test mass and a set of micro-Newton colloidal thrusters. The Disturbance Reduction System is designed to maintain a spacecraft's position with respect to the free-floating test mass to less than 10 nm/ square root of Hz, over the frequency range 10(exp -3) Hz to 10(exp -2) Hz. This paper presents the design and analysis of the coupled drag-free and attitude control system that closes the loop between the gravitational reference sensor and the micro-Newton thrusters while incorporating star tracker data at low frequencies. The effects of actuation and measurement noise and disturbances on the spacecraft and test masses are evaluated in a seven-degree-of-freedom planar model incorporating two translational and one rotational degrees of freedom for the spacecraft and two translational degrees of freedom for each test mass.

Maghami, Peiman↗

Passive Millimeter-wave Signatures of Ice Particles in Hurricane Erin

Observations of Hurricane Erin (2001) taken during the Fourth Convection and Moisture Experiment (CAMEX-Q) are used to elucidate relationships between measurements and models. Measurements include active and passive microwave sensors, and dropsondes. Models used in the analysis include radiative transfer (RT) models, mesoscale models (MM5), and particle parameterizations. Various combinations of the models and observational constraints are used in the RT model to provide calculated brightness temperatures to compare to the passive observations. In order to match the wide frequency range 10 to 183±10 GHg model modifications were needed. The 55.5 GHz channel provided insight to the tropospheric temperature profile, while the 10 GHz channel provided knowledge of (near) ocean surface conditions. The channels less than ~90 GHz are mostly responsive to liquid in the cloud, while higher frequencies respond to ice particles in the cloud.

Ice clouds↗

Phase Calibration of Microphones by Measurement in the Free-field

Over the past several years, significant effort has been expended at NASA Langley developing new Micro-Electro-Mechanical System (MEMS)-based microphone directional array instrumentation for high-frequency aeroacoustic measurements in wind tunnels. This new type of array construction solves two challenges which have limited the widespread use of large channel-count arrays, namely by providing a lower cost-per-channel and a simpler method for mounting microphones in wind tunnels and in field-deployable arrays. The current generation of array instrumentation is capable of extracting accurate noise source location and directivity on a variety of airframe components using sophisticated data reduction algorithms [1-2]. Commercially-available MEMS microphones are condenser-type devices and have some desirable characteristics when compared with conventional condenser-type microphones. The most important advantages of MEMS microphones are their size, price, and power consumption. However, the commercially-available units suffer from certain important shortcomings. Based on experiments with array prototypes, it was found that both the bandwidth and the sound pressure limit of the microphones should be increased significantly to improve the performance and flexibility of the microphone array [3]. It was also desired to modify the packaging to eliminate unwanted Helmholtz resonance s exhibited by the commercial devices. Thus, new requirements were defined as follows: Frequency response: 100 Hz to 100 KHz (+/-3dB) Upper sound pressure limit: Design 1: 130 dB SPL (THD less than 5%) Design 2: 150-160 dB SPL (THD less than 5%) Packaging: 3.73 x 6.13 x 1.3 mm can with laser-etched lid. In collaboration with Novusonic Acoustic Innovation, NASA modified a Knowles SiSonic MEMS design to meet these new requirements. Coupled with the design of the enhanced MEMS microphones was the development of a new calibration method for simultaneously obtaining the sensitivity and phase response of the devices over their entire broadband frequency range. Traditionally, electrostatic actuators (EA) have been used to characterize air-condenser microphones; however, MEMS microphones are not adaptable to the EA method due to their construction and very small diaphragm size [4]. Hence a substitution based, free-field method was developed to calibrate these microphones at frequencies up to 80 kHz. The technique relied on the use of a random, ultrasonic broadband centrifugal sound source located in a small anechoic chamber. The free-field sensitivity (voltage per unit sound pressure) was obtained using the procedure outlined in reference 4. Phase calibrations of the MEMS microphones were derived from cross spectral phase comparisons between the reference and test substitution microphones and an adjacent and invariant grazing-incidence 1/8-inch standard microphone. The free-field calibration procedure along with representative sensitivity and phase responses for the new high-frequency MEMS microphones are presented here.

Shams, Qamar A.↗

Ionization of N{sub 2} in radio-frequent electric field

Rate coefficients for the electron impact ionization of the N{sub 2} molecule are calculated in non-equilibrium conditions in the presence of time-dependent electric field. A Monte Carlo simulation has been developed in order to determine non-equilibrium electron energy distribution functions within one period of the radio-frequent (RF) electric field. By using these distribution functions, rate coefficients for ionization of the N{sub 2} molecule have been obtained time resolved within one period in the frequency range from 13.56 up to 500 MHz, at effective reduced electric field values up to 700 Td. This work presents an insight into the temporal characteristics of ionizing process and provides the ionization rate coefficients that can be of great use for correct implementation in modeling RF plasma discharges. A behavior of rate coefficients under the influence of magnitude and frequency of the fields was studied separately revealing some interesting features in time dependence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Change of translational-rotational coupling in liquids revealed by field-cycling {sup 1}H NMR

Applying the field-cycling nuclear magnetic resonance technique, the frequency dependence of the {sup 1}H spin-lattice relaxation rate, R{sub 1}(ω)=T{sub 1}{sup −1}(ω), is measured for propylene glycol (PG) which is increasingly diluted with deuterated chloroform. A frequency range of 10 kHz–20 MHz and a broad temperature interval from 220 to about 100 K are covered. The results are compared to those of experiments, where glycerol and o-terphenyl are diluted with their deuterated counter-part. Reflecting intra- as well as intermolecular relaxation, the dispersion curves R{sub 1}(ω,x) (x denotes mole fraction PG) allow to extract the rotational time constant τ{sub rot}(T, x) and the self-diffusion coefficient D(T, x) in a single experiment. The Stokes-Einstein-Debye (SED) relation is tested in terms of the quantity D(T, x) τ{sub rot}(T, x) which provides a measure of an effective hydrodynamic radius or equivalently of the spectral separation of the translational and the rotational relaxation contribution. In contrast to o-terphenyl, glycerol and PG show a spectral separation much larger than suggested by the SED relation. In the case of PG/chloroform mixtures, not only an acceleration of the PG dynamics is observed with increasing dilution but also the spectral separation of rotational and translational relaxation contributions continuously decreases. Finally, following a behavior similar to that of o-terphenyl already at about x = 0.6; i.e., while D(T, x) τ{sub rot}(T, x) in the mixture is essentially temperature independent, it strongly increases with x signaling thus a change of translational-rotational coupling. This directly reflects the dissolution of the hydrogen-bond network and thus a change of solution structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE LOW-FREQUENCY RADIO CATALOG OF FLAT-SPECTRUM SOURCES

A well known property of the γ-ray sources detected by Cos-B in the 1970s, by the Compton Gamma-Ray Observatory in the 1990s, and recently by the Fermi observations is the presence of radio counterparts, particularly for those associated with extragalactic objects. This observational evidence is the basis of the radio-γ-ray connection established for the class of active galactic nuclei known as blazars. In particular, the main spectral property of the radio counterparts associated with γ-ray blazars is that they show a flat spectrum in the GHz frequency range. Our recent analysis dedicated to search blazar-like candidates as potential counterparts for the unidentified γ-ray sources allowed us to extend the radio-γ-ray connection in the MHz regime. We also showed that blazars below 1 GHz maintain flat radio spectra. Thus, on the basis of these new results, we assembled a low-frequency radio catalog of flat-spectrum sources built by combining the radio observations of the Westerbork Northern Sky Survey and of the Westerbork in the southern hemisphere catalog with those of the NRAO Very Large Array Sky survey (NVSS). This could be used in the future to search for new, unknown blazar-like counterparts of γ-ray sources. First, we found NVSS counterparts of Westerbork Synthesis Radio Telescope radio sources, and then we selected flat-spectrum radio sources according to a new spectral criterion, specifically defined for radio observations performed below 1 GHz. We also described the main properties of the catalog listing 28,358 radio sources and their logN-logS distributions. Finally, a comparison with the Green Bank 6 cm radio source catalog was performed to investigate the spectral shape of the low-frequency flat-spectrum radio sources at higher frequencies.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of noise in Josephson-effect mixers

We present new heterodyne receiver results obtained at 100 GHz using resistively-shunted Nb and NbN tunnel junctions. In addition, we have carried out accurate measurements of the available noise power of these devices at the L-band (1.5 GHz) IF (infrasonic) frequency. Both the heterodyne and the output noise measurements show that the noise of these devices can be a factor of five or more higher than that predicted by the simple current-biased RSJ model. The noise approaches the appropriate thermal or thermal and shot noise limits for bias voltages where the nonlinearity is not strong (i.e., V greater than I(sub C)R(sub N)), but as expected from the RSJ model, can be significantly higher at the low voltages where the mixers are typically biased. The bias voltage dependence of the noise shows structure which is associated with resonances in the RF embedding circuit. Surprisingly, we find that changes in the high-frequency (100 GHz) impedance presented to the junction can dramatically affect the magnitude and voltage dependence of the low-frequency (1.5 GHz) noise. This emphasizes the necessity of very closely matching the junction to free space over a wide frequency range.

NOISE MEASUREMENT↗

Electromagnetic interference shielding effectiveness of polypropylene/conducting fiber composites

Electromagnetic released from the automotive electronic parts is harmful to human body. Electromagnetic interference (EMT) shielding refers to the reflection and/or adsorption of electromagnetic radiation by a material, which thereby acts as a shield against the penetration of the radiation through the shield. Polypropylene (PP)/conductive micro fiber composites containing various fiber contents and fiber length were injection-molded. The effect of fiber content and length on electrical properties of the composites was studied by electrical resistivity and EMT shielding measurements. The through-plane electrical conductivity and dielectric permittivity were obtained by measuring dielectric properties. The EMT shielding effectiveness (SE) was investigated by using S-parameter in the range of 100 ~ 1500 MHz. Reflection, absorption and multiple-reflection are the EMT attenuation mechanisms. From the measurement of S-Parameters, the absorption coefficient, reflection coefficient, and the shielding efficiency of the materials were calculated. The EMT SE of PP/conducing fiber composites is 40 dB over a wide frequency range up to 1.5 GHz, which is higher than that of PP/talc composite used automotive parts, viz. 0 dB.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Planar multifrequency mid-IR microwave-pumped lasers

The characteristics of planar repetitively pulsed diffusion-cooled HF, DF, HF – DF, Xe, and HF – DF – Xe(Kr) lasers pumped by a microwave discharge (2.45 GHz) are studied depending on the pump pulse duration (10 – 40 μs) and repletion rate (50 – 400 Hz), as well as on the composition and pressure of the working gas mixture (30 – 200 Torr) at low (to 0.6 L s{sup −1}) gas flow rates. It is demonstrated for the first time that a HF – DF – Xe gas-discharge laser may simultaneously operate as a HF – DF chemical molecular laser and a recombination laser based on xenon atom transitions and generate broadband (octave) radiation in the range 2.0 – 4.2 μm with an average output power of 43 mW and an efficiency of 0.9 %. With substitution of xenon for krypton, lasing in a HF – DF – Kr laser is obtained at wavelengths of 2.52 – 4.15 μm. Lasing in a HF – DF laser was achieved simultaneously in two spectral regions (2.7 – 2.9 and 3.6 – 4.2 μm) with an output power of ∼50 mW. It is found that a decrease in the pump pulse duration with a simultaneous increase in the pulse repletion rate for retaining the average energy deposition leads to an increase in the average output power and efficiency of the laser. At low pulse repetition rates (50 – 100 Hz) and a low gas mixture flow rate, helium buffer gas can be effectively substituted for neon. Operation of the Xe laser was achieved in the spectral range 2.03 – 3.65 μm with an average output power of 580 Mw at a pump pulse duration of 20 μs, a pulse repetition rate to 10 kHz, and a maximum efficiency of 55 %. The obtained experimental results demonstrate the possibility of creating broadband HF – DF – Xe lasers emitting in the frequency range 2 – 4 μm with a desired ratio of intensities in different spectral ranges. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-frequency gravitational wave detection by the BREAD experiment

The use of experiments searching for light axion dark matter as high-frequency gravitational wave detectors has garnered increasing attention in recent years. We explore the capabilities of the Broadband Reflector Experiment for Axion Detection (BREAD) in probing the GW parameter space and study the directional dependence of its coverage. This detector can investigate frequencies ranging from 0.05 to 200 THz. We find that by employing single photon detectors, BREAD is sensitive to GWs with characteristic strains as low as 10 −21 at 0.1 THz and 10 −25 at 200 THz with a year exposure time, making it competitive with other proposals operating at similar frequencies.

axions↗

Searching for synchrotron emission from the geminga TeV halo using the planck satellite

Pulsars convert a significant fraction of their total spin-down power into very high-energy electrons, leading to the formation of TeV halos. While these halos are well characterized at TeV energies, it remains unclear whether pulsars also accelerate electrons efficiently at lower energies and how these particles propagate through their surrounding environments. We aim to test whether synchrotron emission from $\sim 50$–$300 \, \textrm{GeV}$ electrons around the Geminga pulsar can be detected in the frequency range observed by the Planck satellite. This would help constrain low-energy particle acceleration and diffusion in the vicinity of pulsars. We model the expected synchrotron emission from Geminga’s TeV halo based on various diffusion and injection spectrum scenarios and compare these predictions to publicly available multi-frequency Planck data. We find no conclusive evidence of spatially extended synchrotron emission associated with Geminga in any of Planck’s frequency bands. Our calculations show that even under favorable diffusion and injection conditions, the predicted synchrotron flux lies well below Planck’s measured background levels.

79 ASTRONOMY AND ASTROPHYSICS↗

The Semicircular Canal Microphonic

Present experiments were designed to quantify the alternating current (AC) component of the semicircular canal microphonic for angular motion stimulation as a function of stimulus frequency and amplitude. The oyster toadfish, Opsanus tau, was used as the experimental model. Calibrated mechanical indentation of the horizontal canal duct was used as a stimulus to generate hair-cell and afferent responses reproducing those present during head rotation. Sensitivity to polarization of the endolymph DC voltage re: perilymph was also investigated. Modulation of endolymph voltage was recorded using conventional glass electrodes and lock-in amplification over the frequency range 0.2-80 Hz. Access to the endolymph for inserting voltage recording and current passing electrodes was obtained by sectioning the anterior canal at its apex and isolating the cut ends in air. For sinusoidal stimulation below approx.10 Hz, the horizontal semicircular canal AC microphonic was nearly independent of stimulus frequency and equal to approximately 4 microV per micron indent (equivalent to approx. 1 microV per deg/s). A saturating nonlinearity decreasing the microphonic gain was present for stimuli exceeding approx.3 micron indent (approx. 12 deg/s angular velocity). The phase was not sensitive to the saturating nonlinearity. The microphonic exhibited a resonance near 30Hz consistent with basolateral current hair cell resonance observed previously in voltage-clamp records from semicircular canal hair cells. The magnitude and phase of the microphonic exhibited sensitivity to endolymphatic polarization consistent with electro-chemical reversal of hair cell transduction currents.

Rabbitt, R. D.↗

Core Analysis Combining MT (TIPPER) and Dielectric Sensors (Sans EC) in Earth and Space

On terrestrial planets and moons of our solar system cores reveal details about a geological structure's formation, content, and history. The strategy for the search for life is focused first on finding water which serves as a universal solvent, and identifying the rocks which such solvent act upon to release the constituent salts, minerals, ferrites, and organic compounds and chemicals necessary for life. Dielectric spectroscopy measures the dielectric properties of a medium as a function of frequency. Reflection measurements in the frequency range from 300 kHz to 300 MHz were carried out using RF and microwave network analyzers interrogating SansEC Sensors placed on clean geological core samples. These were conducted to prove the concept feasibility of a new geology instrument useful in the field and laboratory. The results show that unique complex frequency spectra can be acquired for a variety of rock core samples. Using a combination of dielectric spectroscopy and computer simulation techniques the magnitude and phase information of the frequency spectra can be converted to dielectric spectra. These low-frequency dielectric properties of natural rock are unique, easily determined, and useful in characterizing geology. TIPPER is an Electro-Magnetic Passive-Source Geophysical Method for Detecting and Mapping Geothermal Reservoirs and Mineral Resources. This geophysical method uses distant lightning and solar wind activity as its energy source. The most interesting deflections are caused by the funneling of electrons into more electrically conductive areas like mineralized faults, water or geothermal reservoirs. We propose TIPPER to be used with SansEC for determining terrain/ocean chemistry, ocean depth, geomorphology of fracture structures, and other subsurface topography characteristics below the ice crust of Jovian moons. NASA envisions lander concepts for exploration of these extraterrestrial icy surfaces and the oceans beneath. One such concept would use a nuclear powered heated tip for melting through the ice sheath of Europa and inserting a down hole SansEC with TIPPER interface. NASA's Juno space probe already on the way to Jupiter as part of the Exploration New Frontiers Program and the planned Europa mission will conduct detailed reconnaissance of Jupiter's moon Europa and investigate whether the icy moon could harbor conditions suitable for life. It has already been observed that Jovian moons have auroras that may serve as naturally occurring active energy sources for a TIPPER instrument.

Mound, Michael C.↗

SOLAR RADIO BURSTS WITH SPECTRAL FINE STRUCTURES IN PREFLARES

Good observations of preflare activities are important for us to understand the origin and triggering mechanism of solar flares, and to predict the occurrence of solar flares. This work presents the characteristics of microwave spectral fine structures as preflare activities of four solar flares observed by the Ondřejov radio spectrograph in the frequency range of 0.8-2.0 GHz. We found that these microwave bursts which occurred 1-4 minutes before the onset of flares have spectral fine structures with relatively weak intensities and very short timescales. They include microwave quasi-periodic pulsations with very short periods of 0.1-0.3 s and dot bursts with millisecond timescales and narrow frequency bandwidths. Accompanying these microwave bursts are filament motions, plasma ejection or loop brightening in the EUV imaging observations, and non-thermal hard X-ray emission enhancements observed by RHESSI. These facts may reveal certain independent, non-thermal energy releasing processes and particle acceleration before the onset of solar flares. They may help us to understand the nature of solar flares and to predict their occurrence.

79 ASTRONOMY AND ASTROPHYSICS↗

Electromagnetic and thermal properties of three-dimensional printed multilayered nano-carbon/poly(lactic) acid structures

A new type of light-weight material produced by 3D printing consisting of nano-carbon doped polymer layer followed by a dielectric polymer layer is proposed. We performed temperature dependent characterization and measured the electromagnetic (EM) response of the samples in the GHz and THz range. The temperature dependent structural characteristics, crystallization, and melting were observed to be strongly affected by the presence and the number of nano-carbon doped layers in the sandwich structure. The electromagnetic measurements show a great potential of such a type of periodic material for electromagnetic compatibility applications in microwave frequency range. Sandwich structures containing only two nano-carbon layers already become not transparent to the microwaves, giving an electromagnetic interference shielding efficiency at the level of 8–15 dB. A sandwich consisting of one nano-carbon doped and one polymer layer is opaque for THz radiation, because of 80% of absorption. These studies serve as a basis for design and realization of specific optimal geometries of meta-surface type with the 3D printing technique, in order to reach a high level of electromagnetic interference shielding performance for real world EM cloaking and EM ecology applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A comparison of digital radiography systems in terms of effective detective quantum efficiency

Purpose: The purpose of this study is to compare digital radiography systems using the metric effective detective quantum efficiency (eDQE), which better reflects digital radiography imaging system performance under clinical operating conditions, in comparison with conventional metrics such as modulation transfer function (MTF), normalized noise power spectra (NNPS), and detective quantum efficiency (DQE). Methods: The eDQE was computed by the calculation of the MTF, the NNPS, the phantom attenuation and scatter, and estimation of x-ray flux. The physical characterization of the systems was obtained with the standard beam conditions RQA5 and RQA9, using the PA Chest phantom proposed by AAPM Report no. 31 simulating the attenuation and scatter characteristics of the adult human thorax. The MTF (eMTF) was measured by using an edge test placed at the frontal surface of the phantom, the NNPS (eNNPS) was calculated from images of the phantom acquired at three different exposure levels covering the operating range of the system (E{sub 0}, which is the exposure at which a system is normally operated, 1/3 E{sub 0}, and 3 E0), and scatter measurements were assessed by using a beam-stop technique. The integral of DQE (IDQE) and eDQE (IeDQE) was calculated over the whole spatial frequency range. Results: The eMTF results demonstrate degradation due to magnification and the presence of scattered radiation. The eNNPS was influenced by the grid presence, and in some systems, it contained structured noise. At typical clinical exposure levels, the magnitude of eDQE(0) with respect to DQE(0) at RQA9 beam conditions was 13%, 17%, 16%, 36%, and 24%, respectively, for Carestream DRX-1, Carestream DRX-1C, Carestream Direct View CR975, Philips Digital Diagnost VM, and GE Revolution XR/d. These results were confirmed by the ratio of IeDQE and IDQE in the same conditions. Conclusions: The authors confirm the robustness and reproducibility of the eDQE method. As expected, the DR systems performed better than the CR systems due to their superior signal-to-noise transfer characteristics. The results of this study suggest the eDQE method may provide an opportunity to more accurately assess the clinical performance of digital radiographic imaging systems by accounting for factors such as the presence of scatter, use of an antiscatter grid, and magnification and focal spot blurring effects, which are not reflected in conventional DQE measures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the feasibility of electron cyclotron heating of overcritical plasma in a magnetic mirror trap

The feasibility of matching electromagnetic radiation in the electron cyclotron frequency range to a dense plasma in an open magnetic trap by producing an inverted (with a minimum on the axis) plasma density profile is discussed. The use of such a profile shows promise for the implementation of efficient cyclotron heating at plasma densities above the critical density, at which the Langmuir frequency is equal to the heating radiation frequency. Examples of the magnetic field and plasma density distributions in a mirror trap are presented for which analysis of the beam trajectories shows the feasibility of efficient electron cyclotron absorption of microwave beams in overcritical plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗