Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Formation pathway, structural characterization and optimum processing parameters of synthetic topaz – Al{sub 2}SiO{sub 4}(OH,F){sub 2} – by CVD

A novel synthesis route for topaz (Al{sub 2}SiO{sub 4}(OH,F){sub 2}) by chemical vapor deposition (CVD) using Na{sub 2}SiF{sub 6} as solid precursor was developed. Synthesis tests were conducted with and without a flow of nitrogen, positioning the Al(OH){sub 3} substrate at 0° and 90° with respect to the gas flow direction, at 700 and 750 °C, for 60 and 90 min, respectively. It was found that topaz is synthesized through two pathways, directly and indirectly, involving a series of endothermic and exothermic, heterogeneous and homogeneous reactions between Al(OH){sub 3} and SiF{sub 4}(g). Analytical structural determination confirmed existence of orthorhombic polycrystals with lattice parameters of a =4.6558 Å, b=8.8451 Å and c=8.4069 Å. According to ANOVA, while temperature, time and interaction of substrate angular position with atmosphere (P×A) are the parameters that most significantly influence the variability in the amount of topaz formed – equivalent contributions of 31% – topaz lattice parameters are mostly impacted by the same factors (T, t, P, A), but without the interaction factor. The projected amount of topaz is in good agreement with that obtained in confirmation tests under optimal conditions: Al(OH){sub 3} substrate compact placed at 0°, treated at 750 °C for 90 min in the absence of N{sub 2}. - Highlights: • Topaz synthesis as a unique phase by CVD, using solid precursor Na{sub 2}SiF{sub 6} is feasible. • Two pathways, a series of endothermic/exothermic, heterogeneous/homogeneous reactions. • Crystal structure, orthorhombic polycrystals: a =4.6558 Å, b=8.8451 Å, c=8.4069 Å. • Anova: amount of topaz formed and lattice parameters are impacted by same factors. • Projection of topaz quantity in good agreement with those from confirmation tests.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theoretical and testing performance of an innovative indirect evaporative chiller

An indirect evaporative chiller is a device used to produce chilled water at a temperature between the wet bulb temperature and dew point of the outdoor air, which can be used in building HVAC systems. This article presents a theoretical analysis and practical performance of an innovative indirect evaporative chiller. First, the process of the indirect evaporative chiller is introduced; then, the matching characteristics of the process are presented and analyzed. It can be shown that the process that produces cold water by using dry air is a nearly-reversible process, so the ideal produced chilled water temperature of the indirect evaporative chiller can be set close to the dew point temperature of the chiller's inlet air. After the indirect evaporative chiller was designed, simulations were done to analyze the output water temperature, the cooling efficiency relative to the inlet dew point temperature, and the COP that the chiller can performance. The first installation of the indirect evaporative chiller of this kind has been run for 5 years in a building in the city of Shihezi. The tested output water temperature of the chiller is around 14-20 C, which is just in between of the outdoor wet bulb temperature and dew point. The tested COP{sub r,s} of the developed indirect evaporative chiller reaches 9.1. Compared with ordinary air conditioning systems, the indirect evaporative chiller can save more than 40% in energy consumption due to the fact that the only energy consumed is from pumps and fans. An added bonus is that the indirect evaporative chiller uses no CFCs that pollute to the aerosphere. The tested internal parameters, such as the water-air flow rate ratio and heat transfer area for each heat transfer process inside the chiller, were analyzed and compared with designed values. The tested indoor air conditions, with a room temperature of 23-27 C and relative humidity of 50-70%, proved that the developed practical indirect evaporative chiller successfully satisfy the indoor air conditioning load for the demo building. The indirect evaporative chiller has a potentially wide application in dry regions, especially for large scale commercial buildings. Finally, this paper presented the geographic regions suitable for the technology worldwide. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low temperature oxidation of methylpropyl ether

Ethers are potential high-performance fuels that can be produced from renewable carbon sources such as biomass, but their combustion properties are not clearly understood. The cetane numbers (CN) for ethers, a measure of autoignition tendency, can range from less than 10 to greater than 100, and predictive tools based upon the molecular structures are desirable in order to focus fuel development research. In this study, we used molecular modeling, chemical kinetic modeling, and experimental measurements to understand the important reactions that lead to the autoignition of methylpropyl ether (MPE), a model for ethers containing alkyl chains long enough for intramolecular hydrogen transfer. These reactions are known to be important in the autoignition of alkanes and ethers and we propose to investigate the relationship between alkyl and ether reaction pathways. A reaction mechanism for MPE was created using MIT’s Reaction Mechanism Generator (RMG) and G4 quantum calculation results and models were tested using the ChemKin Pro suite of software. Results from atmospheric pressure, flow tube reactor experiments and rapid compression machine (RCM) experiments were used to test the kinetic model and suggest refinements.

autoignition↗

Low Temperature Oxidation of Methylpropyl Ether

Ethers are potential high-performance fuels that can be produced from renewable carbon sources such as biomass, but their combustion properties are not clearly understood. The cetane numbers (CN) for ethers, a measure of autoignition tendency, can range from less than 10 to greater than 100, and predictive tools based upon the molecular structures are desirable in order to focus fuel development research. In this study, we used molecular modeling, chemical kinetic modeling, and experimental measurements to understand the important reactions that lead to the autoignition of methylpropyl ether (MPE), a model for ethers containing alkyl chains long enough for intramolecular hydrogen transfer. These reactions are known to be important in the autoignition of alkanes and ethers and we propose to investigate the relationship between alkyl and ether reaction pathways. A reaction mechanism for MPE was created using MIT's Reaction Mechanism Generator (RMG) and G4 quantum calculation results and models were tested using the ChemKin Pro suite of software. Results from atmospheric pressure, flow tube reactor experiments and rapid compression machine (RCM) experiments were used to test the kinetic model and suggest refinements.

33 ADVANCED PROPULSION SYSTEMS↗

UF6 Density and Mass Flow Measurements for Enrichment Plants using Acoustic Techniques

A key enabling capability for enrichment plant safeguards being considered by the International Atomic Energy Agency (IAEA) is high-accuracy, noninvasive, unattended measurement of UF6 gas density and mass flow rate. Acoustic techniques are currently used to noninvasively monitor gas flow in industrial applications; however, the operating pressures at gaseous centrifuge enrichment plants (GCEPs) are roughly two orders magnitude below the capabilities of commercial instrumentation. Pacific Northwest National Laboratory is refining acoustic techniques for estimating density and mass flow rate of UF6 gas in scenarios typical of GCEPs, with the goal of achieving 1% measurement accuracy. Proof-of-concept laboratory measurements using a surrogate gas for UF6 have demonstrated signatures sensitive to gas density at low operating pressures such as 10–50 Torr, which were observed over the background acoustic interference. Current efforts involve developing a test bed for conducting acoustic measurements on flowing SF6 gas at representative flow rates and pressures to ascertain the viability of conducting gas flow measurements under these conditions. Density and flow measurements will be conducted to support the evaluation. If successful, the approach could enable an unattended, noninvasive approach to measure mass flow in unit header pipes of GCEPs.

Good, Morris S.↗

Photoacoustic infrared spectroscopy for conducting gas tracer tests and measuring water saturations in landfills

Highlights: Black-Right-Pointing-Pointer Photoacoustic infrared spectroscopy tested for measuring tracer gas in landfills. Black-Right-Pointing-Pointer Measurement errors for tracer gases were 1-3% in landfill gas. Black-Right-Pointing-Pointer Background signals from landfill gas result in elevated limits of detection. Black-Right-Pointing-Pointer Technique is much less expensive and easier to use than GC. - Abstract: Gas tracer tests can be used to determine gas flow patterns within landfills, quantify volatile contaminant residence time, and measure water within refuse. While gas chromatography (GC) has been traditionally used to analyze gas tracers in refuse, photoacoustic spectroscopy (PAS) might allow real-time measurements with reduced personnel costs and greater mobility and ease of use. Laboratory and field experiments were conducted to evaluate the efficacy of PAS for conducting gas tracer tests in landfills. Two tracer gases, difluoromethane (DFM) and sulfur hexafluoride (SF{sub 6}), were measured with a commercial PAS instrument. Relative measurement errors were invariant with tracer concentration but influenced by background gas: errors were 1-3% in landfill gas but 4-5% in air. Two partitioning gas tracer tests were conducted in an aerobic landfill, and limits of detection (LODs) were 3-4 times larger for DFM with PAS versus GC due to temporal changes in background signals. While higher LODs can be compensated by injecting larger tracer mass, changes in background signals increased the uncertainty in measured water saturations by up to 25% over comparable GC methods. PAS has distinct advantages over GC with respect to personnel costs and ease of use, although for field applications GC analyses of select samples are recommended to quantify instrument interferences.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Idaho National Laboratory Advanced Reactor Technologies Quality Assurance Program Plan

This QAPP covers INL ART R&D, licensing, and program support activities. QA implementing procedures will be identified for all activities to ensure work is documented and the results are capable of successfully completing a technical review by DOE. For work performed by other organizations under contract or other agreements with INL, applicable requirements will be flowed down through the contract or other agreements, but the organizations will be responsible to implement the flowed down requirements through their own specific implementing procedures. This QAPP also covers implementation of software QA (SQA) requirements for software used exclusively by INL ART. Software that is used to support multiple INL programs/projects is not covered by this QAPP; the responsibility for implementing SQA requirements for that software resides with the owners and respective managers of the software. This QAPP does not cover activities for installing and operating experiments in the Advanced Test Reactor (ATR) at INL, nor does it cover ATR facility modifications designed to meet INL ART testing needs (such as temperature, pressure, gas flow, and control systems). Those activities are controlled by the INL QAP and specific ATR implementing procedures. ATR facility management and INL ART management jointly approve experiment designs and functional system requirements. This QAPP does apply to INL ART R&D experiments that will be inserted into ATR and any support activities associated with those R&D activities. This QAPP does not cover activities for installing and operating general post irradiation examination (PIE) test equipment in Materials and Fuels Complex (MFC) facilities. Those activities are controlled by the INL QAP and MFC implementing procedures. However, this QAPP does apply to MFC facility modifications designed to meet specific INL ART testing needs. It also applies to INL ART experiments that will have PIE performed on them and any support activities associated with the PIE activities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Micro-Gas-Analyzer MEMS Active Pressure Valves Testing and Design

Micro-Gas-Analyzers have many applications in detecting chemical compounds present in the air. MEMS valves are used to perform sampling of gasses, as they enable control of fluid flow at the micro level. Current generation electrostatically actuated MEMS valves were tested to determine their ability to hold off a given gauge pressure with an applied voltage. Current valve designs were able to hold off 98 psi with only 82 V applied to the valves. The valves were determined to be 1.83 times more efficient than older valve designs, due to increasing the electrostatic area of the valve and trapping oxide between polysilicon layers. Newer valve designs were also proposed and modeled using ANSYS multiphysics, which should be able to hold off 100 psi with only 29 V needed. This performance would be 2.82 times more efficient than current designs, or 5.17 times more efficient than older valve designs. This will be accomplished by further increasing the valve radius and decreasing the gap between the valve boss and electrode.

42 ENGINEERING↗

Computational Fluid Dynamics Modeling of The Dalles Project: Effects of Spill Flow Distribution Between the Washington Shore and the Tailrace Spillwall

The U.S. Army Corps of Engineers-Portland District (CENWP) has ongoing work to improve the survival of juvenile salmonids (smolt) migrating past The Dalles Dam. As part of that effort, a spillwall was constructed to improve juvenile egress through the tailrace downstream of the stilling basin. The spillwall was designed to improve smolt survival by decreasing smolt retention time in the spillway tailrace and the exposure to predators on the spillway shelf. The spillwall guides spillway flows, and hence smolt, more quickly into the thalweg. In this study, an existing computational fluid dynamics (CFD) model was modified and used to characterize tailrace hydraulics between the new spillwall and the Washington shore for six different total river flows. The effect of spillway flow distribution was simulated for three spill patterns at the lowest total river flow. The commercial CFD solver, STAR-CD version 4.1, was used to solve the unsteady Reynolds-averaged Navier-Stokes equations together with the k-epsilon turbulence model. Free surface motion was simulated using the volume-of-fluid (VOF) technique. The model results were used in two ways. First, results graphics were provided to CENWP and regional fisheries agency representatives for use and comparison to the same flow conditions at a reduced-scale physical model. The CFD results were very similar in flow pattern to that produced by the reduced-scale physical model but these graphics provided a quantitative view of velocity distribution. During the physical model work, an additional spill pattern was tested. Subsequently, that spill pattern was also simulated in the numerical model. The CFD streamlines showed that the hydraulic conditions were likely to be beneficial to fish egress at the higher total river flows (120 kcfs and greater, uniform flow distribution). At the lowest flow case, 90 kcfs, it was necessary to use a non-uniform distribution. Of the three distributions tested, splitting the flow evenly between Bay 7 and Bay 8 had hydraulics deemed most beneficial for egress by CENWP fisheries biologists and regional fishery agency representatives. The numerical and physical model results were very similar, building confidence in both hydraulic tools.

13 HYDRO ENERGY↗

Prediction of PbLi fluid flow and temperature field in a thermal convection loop for qualification of fusion materials

Two modeling tools, a thermohydraulics code and a computational model in COMSOL Multiphysics, have been developed, tested and then applied to the analysis of fluid flow and heat transfer in a thermal convection loop (TCL). Such a device has recently been used to experimentally evaluate corrosion compatibility of APMT (Fe–21Cr–5Al–3Mo) steel with high-temperature molten eutectic lead-lithium (PbLi) alloy at Oak Ridge National Lab, TN, USA. Here, the 1-D thermohydraulics code allows for rapid calculations of the loop parameters as a function of the applied heat flux. The supplemental COMSOL finite-element computations provide detailed 3-D velocity and temperature field data but are much more time consuming. Both modelling tools demonstrate an excellent agreement in the computed circulation velocity as well as maximum and minimum temperatures. The performed TCL analysis focuses on flow development in the “hot” and “cold” legs, formation of Dean vortices in corner regions, blocking effect of the immersed samples, and radiative and convective cooling effects under the experiment-relevant conditions for Prandtl number Pr = 0.015, Grashof numbers Gr ~10 7 , and Reynolds numbers Re ~10 4 .

36 MATERIALS SCIENCE↗

Cesium-Technetium Volatility in the DFLAW Flow-Sheet (VSL-21R4780-1 Rev. 0)

The tests were conducted on the DM10 vitrification system with prototypical off-gas treatment system, which includes an SBS and WESP. This allowed determination of the partitioning and speciation of cesium between the melter and the off-gas system components, including liquid effluents from the SBS and WESP. The tests were conducted using simulated Hanford LAW AP-107, which is the planned first feed to DFLAW, at a nominal feed concentration of 5.6 molar Na over about 200 hours of testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Acoustic Techniques for UF6 Density and Mass Flow Measurements

A key enabling capability for enrichment plant safeguards is high-accuracy, non-invasive, unattended measurement of UF6 gas density and mass flow rate. Acoustic techniques are currently used to non-invasively monitor gas flow in industrial applications; however, the operating pressures at gaseous centrifuge enrichment plants (GCEPs) are roughly two orders magnitude below the capabilities of commercial instrumentation. Pacific Northwest National Laboratory is refining acoustic techniques for estimating density and mass flow rate of UF6 gas in scenarios typical of gaseous centrifuge enrichment plants, with the goal of achieving 1% measurement uncertainty. Proof-of-concept laboratory measurements of UF6 have demonstrated signature sensitivity to gas density at pressures equivalent to 10-50 Torr of UF6, typical pressures for GCEP unit header pipes. This sensitivity was clearly observable above background acoustic interference. Current efforts involve developing a test bed for conducting acoustic measurements on flowing surrogate gas, air and SF6, at representative flow rates and pressures to ascertain the viability of conducting gas flow measurements under these conditions. Density and flow measurements will be conducted to support the evaluation. If successful, the approach could enable an unattended, non-invasive approach to measure UF6 density and mass flow in unit header pipes of GCEPs.

International safeguards instrumentation, acoustic↗

Convective Heat Transfer in Decay Heat Exchanger of Sodium-cooled Fast Reactor

Sodium-to-sodium heat exchangers such as the decay heat exchanger (DHX) are key components of the prototype generation [V sodium-cooled fast reactor (PGSFR). The DHX transfers the decay heat generated in the reactor core to the decay heat removal loop after a reactor shutdown. Shell-and-tube type with straight tube arrangement has been widely adopted for the sodium-to-sodium heat exchanger of the sodium-cooled fast reactor. Thus liquid metal heat transfer characteristics inside the tube and around the tube bundle have to be fully understood to design the sodium-to-sodium heat exchanger and evaluate its thermal performance accurately. Plenty of studies on the convective heat transfer of the liquid metals were conducted to present the Nusselt number (Nu) correlations with respect to the Peclet number (Pe). However, those correlations still deviated from each other considerably and few of correlations for low Pe range (less than 100) have been reported. Accordingly, it is difficult for a design code developer to choose a proper heat transfer coefficient correlation for the sodium-to-sodium heat exchanger particularly in a low flow rate range. Recently, a separate effect test for the DHX has been completed using the STELLA-1 facility at KAERI according to the STELLA program which aims at establishment of separate and integral test database (DB) for the design of the PGSFR. The heat transfer performance test of the DHX was successfully conducted under major operating conditions. The objective of this work is to suggest proper convective heat transfer correlations for tube- and shell-sides of the sodium-to-sodium heat exchanger based on the test DB obtained from STELLA-1. The Pe range of the analyzed experimental data is concentrated on less then 100. The adequacy of the suggested correlations is evaluated by applying to the DHX design code, SHXSA. Based on the DHX test DB of the STELLA-1, the proper convective heat transfer correlations for the tube- and shell-side of sodium-to-sodium heat exchangers were suggested. Two correlation combinations for each side were proposed and turned out to be reasonable through the evaluation using the SHXSA design code: Suggestion no. 1: - Lyon correlation (constant = 4) for tube-side; - Lubarsky-Kaufman correlation for shell-side. Suggestion no. 2: - Modified Lyon correlation (constant = 1.45) for tube-side; - Schad-modified correlation for shell-side The Pe ranges of the DHX test DB were 53 - 225 for the tube-side and 45 - 148 for the shell-side, but most of test conditions were concentrated on the Pe range of less than 100. Two correlation suggestions can be practically used for the design of sodium-to-sodium heat exchangers. However, by utilizing more test DB, it needs to be verified which one is closer to real phenomena. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Perspective on the Successes of the NNSS Underground Test Area (UGTA) Activity - 20221

Between 1951 and 1992, 828 underground nuclear tests were performed at the Nevada National Security Site (NNSS). Underground testing was done in five major testing areas, which included (1) Frenchman Flat, (2) Rainier Mesa/Shoshone Mountain, (3) Yucca Flat/Climax Mine (4) Central Pahute Mesa, and (5) Western Pahute Mesa. About one third of the underground tests were detonated near, at or below the water table, and thus radioactive contamination was introduced to the groundwater system. The U.S. Department of Energy's Underground Test Area (UGTA) Activity was established in the late 1990's to address the fate and movement of residual radioactivity in groundwater, and characterize the risk that it may pose to NNSS workers and the offsite public. It has accomplished this goal through a process of iterative groundwater sampling and numerical groundwater flow and transport modeling, and long-term monitoring. The UGTA Activity draws on the expertise of scientists in the fields of geology, hydrology, radiochemistry, and risk assessment from the U.S. DOE staff, the lead contractor (currently Navarro) and many other organizations, in cooperation with the governing regulatory body, the State of Nevada's Division of Environmental Protection (NDEP). Los Alamos National Laboratory (LANL) is one of the participating research organizations involved with the UGTA Activity. Under the direction of DOE and the lead contractor, LANL's role in UGTA has evolved over time from an initial focus on geologic characterization, to conducting field and laboratory experiments, and finally to its current role of providing modeling and geochemistry expertise to characterize the rates and directions of groundwater and radionuclide movement. In its current role, LANL has either developed or provided the numerical tools for developing flow and transport models in each of the four major testing areas. In addition, LANL has provided an independent assessment of future groundwater flow and transport behavior through the analysis of naturally-occurring geochemical and isotopic tracers in groundwater. The five major testing areas are now in different stages of investigation or closure: (1) Frenchman Flat is in its fifth year of post closure modeling; (2) The Rainier Mesa/Shoshone Mountain Closure Report has been submitted to NDEP and is awaiting approval; (3) The Yucca Flat/Climax Mine Closure Report is under development; and (4) Central and (5) Western Pahute Mesa is still undergoing investigation and flow and transport model development. The success of the UGTA Activity in reaching or approaching closure in three of the five major testing areas is primarily due to the DoE's focus on regulatory closure requirements, but also is in part attributable to a rigorous internal review process and the involvement of NDEP and Nye County water professionals as participants and observers in the reviews. County and state involvement in the internal review process has promoted trust that the U.S. DOE is deeply committed to ensuring the present and future safely of NNSS workers and the surrounding communities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Self-regulating behavior of hybrid membrane systems as demonstrated in an element-scale forward osmosis-reverse osmosis hybrid system

Hybrid membrane systems can be difficult to design due to the requisite flow rate matching between up- and downstream unit operations. In this work, we use a forward osmosis-reverse osmosis (FO-RO) hybrid system to demonstrate how some membrane systems can exhibit self-regulating behavior due to osmotic coupling. This can reduce the need for complex control systems for flow balancing. We show this behavior using a module-scale test bed that can mimic the behavior of larger scale operations. The system shows permeate flow rate near-convergence between the FO and RO modules after startup or when perturbed by a change in RO module pressure. The behavior of this hybrid system demonstrates that some membrane operations can exploit osmotic interdependence, rather than expensive control systems, to achieve steady state operation.

Debottlenecking↗

Space-Time Block Preconditioning for Incompressible Flow

Parallel-in-time methods have become increasingly popular in the simulation of time-dependent numerical PDEs, allowing for the efficient use of additional message passing interface processes when spatial parallelism saturates. Most methods treat the solution and parallelism in space and time separately. In contrast, all-at-once methods solve the full space-time system directly, largely treating time as simply another spatial dimension. All-at-once methods offer a number of benefits over separate treatment of space and time, most notably significantly increased parallelism and faster time to solution (when applicable). However, the development of fast, scalable all-at-once methods has largely been limited to time-dependent (advection-)diffusion problems. This paper introduces the concept of space-time block preconditioning for the all-at-once solution of incompressible flow. By extending well-known concepts of spatial block preconditioning to the space-time setting, we develop a block preconditioner whose application requires the solution of a space-time (advection-)diffusion equation in the velocity block, coupled with a pressure Schur complement approximation consisting of independent spatial solves at each time-step, and a space-time matrix-vector multiplication. The new method is tested on four classical models in incompressible flow. Finally, the results indicate perfect scalability in refinement of spatial and temporal mesh spacing, perfect scalability in nonlinear Picard iteration count when applied to a nonlinear Navier--Stokes problem, and minimal overhead in terms of number of preconditioner applications compared with sequential time-stepping.

97 MATHEMATICS AND COMPUTING↗

Final Report Start-Up and Commissioning Tests on the DuraMelter 1200 HLW Pilot Melter System Using AZ-101 HLW Simulants

This document provides the final report on data and results obtained from commissioning tests performed on the one-third scale DuraMelter{trademark} 1200 (DM 1200) HLW Pilot Melter system that has been installed at VSL with an integrated prototypical off-gas treatment system. That system has replaced the DM1000 system that was used for HLW throughput testing during Part BI [1]. Both melters have similar melt surface areas (1.2 m{sup 2}) but the DM1200 is prototypical of the present RPP-WTP HLW melter design whereas the DM1000 was not. These tests were performed under a corresponding RPP-WTP Test Specification and associated Test Plan. This report is a followup to the previously issued Preliminary Data Summary Report. The DM1200 system will be used for testing and confirmation of basic design, operability, flow sheet, and process control assumptions as well as for support of waste form qualification and permitting. This will include data on processing rates, off-gas treatment system performance, recycle stream compositions, as well as process operability and reliability. Consequently, this system is a key component of the overall HLW vitrification development strategy. The results presented in this report are from the initial series of short-duration tests that were conducted to support the start-up and commissioning of this system prior to conducting the main body of development tests that have been planned for this system. These tests were directed primarily at system 'debugging,' operator training, and procedure refinement. The AZ-101 waste simulant and glass composition that was used for previous testing was selected for these tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation of dilatancy-controlled gas migration processes in saturated bentonite using a coupled multiphase flow and elastoplastic H 2 M model

Dilatancy-controlled gas flow in preferential pathways plays a key role in the safety analysis of radioactive waste repositories. This is particularly the case for bentonite, an often-preferred barrier material. Gas flow in preferential pathways is characterized by localization and spontaneous behavior, which is challenging to simulate in numerical models due to strong hydro-mechanical coupling. To analyze a laboratory experiment in the framework of the DECOVALEX-2023 project, this study introduced a new approach of combining continuous modelling methods with spatial material properties derived from material heterogeneities and experimental observations. The proposed model utilized hydro-mechanical spatial distributions, namely Young's modulus and gas entry pressure, and elastoplasticity combined with a linear swelling model. A conceptual strain-dependent permeability approach simulated dilatancy-controlled gas flow based on hydro-mechanical coupling. To test the effectiveness of the presented approach, a gas injection test in a compacted, saturated bentonite sample was simulated using the open-source code OpenGeoSys 5.8 and compared with experimental observations. The presented methodology is capable of simulating localized gas flow in preferential pathways. The spatial distributions of Young's modulus and gas entry pressure affect the swelling pressure, relative permeability and, in combination with the strain-dependent permeability model, also the intrinsic permeability.

42 ENGINEERING↗