Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “field testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Digital Tools for the Preventive Conservation of Built Heritage: The Church of Santa Ana in Seville

Historic Building Information Modelling (HBIM) plays a pivotal role in heritage conservation endeavours, offering a robust framework for digitally documenting existing structures and supporting conservation practices. However, HBIM’s efficacy hinges upon the implementation of case-specific approaches to address the requirements and resources of each individual asset and context. This paper defines a flexible and generalisable workflow that encompasses various aspects (i.e., documentation, surveying, vulnerability assessment) to support risk-informed decision making in heritage management tailored to the peculiar conservation needs of the structure. This methodology includes an initial investigation covering historical data collection, metric and condition surveys and non-destructive testing. The second stage includes Finite Element Method (FEM) modelling and structural analysis. All data generated and processed are managed in a multi-purpose HBIM model. The methodology is tested on a relevant case study, namely, the church of Santa Ana in Seville, chosen for its historical significance, intricacy and susceptibility to seismic action. The defined level of detail of the HBIM model is sufficient to inform the structural analysis, being balanced by a more accurate representation of the alterations, through linked orthophotos and a comprehensive list of alphanumerical parameters. This ensures an adequate level of information, optimising the trade-off between model complexity, investigation time requirements, computational burden and reliability in the decision-making process. Field testing and FEM analysis provide valuable insight into the main sources of vulnerability in the building, including the connection between the tower and nave and the slenderness of the columns.

Chaves, Estefanía↗

Centrifuge modeling and numerical analysis on lateral performance of mono-bucket foundation for offshore wind turbines

The lateral loading performance of the mono-bucket foundation for offshore wind turbines is investigated in this study through a series of centrifuge tests and numerical analysis. Six mono-bucket models are considered to assess the influences of aspect ratio under the ultimate condition. The FE model is validated against the centrifuge test results, and the failure mechanism of the foundation is revealed. The parametric study and sensitivity analysis of the soil parameters are performed in the numerical simulations. A modified theoretical calculation method is proposed to estimate the ultimate lateral capacity of the suction bucket foundation by solving the limit equilibrium equations. A correction term is added in the calculation using the “m” method. The position of the rotation center is calculated, demonstrating a better accuracy compared to the previously reported geometric method. The modified calculation method is verified against the field test, the centrifuge test, and the laboratory test. The method is proved to be applicable in estimating the lateral performance of the mono-bucket foundation in a general form. Finally, this study aims to provide well-documented data and design references for practical engineers.

17 WIND ENERGY↗

Comparison of planetary bearing load-sharing characteristics in wind turbine gearboxes

Abstract. In this paper, the planetary load-sharing behavior and fatigue life of different wind turbine gearboxes when subjected to rotor moments are examined. Two planetary bearing designs are compared – one design using cylindrical roller bearings with clearance and the other design using preloaded tapered roller bearings to support both the carrier and planet gears. Each design was developed and integrated into a 750 kW dynamometer tests, the loads on each planet bearing row were measured and compared to finite-element models. Bearing loads were not equally shared between the set of cylindrical roller bearings supporting the planets even in pure torque conditions, with one bearing supporting up to 46 % more load than expected. A significant improvement in planetary bearing load sharing was demonstrated in the gearbox with preloaded tapered roller bearings with maximum loads 20 % lower than the gearbox with cylindrical roller bearings. Bearing life was calculated with a representative duty cycle measured from field tests. The predicted fatigue life of the eight combined planet and carrier bearings for the gearbox with preloaded tapered roller bearings is 3.5 times greater than for the gearbox with cylindrical roller bearings. The influence of other factors, such as carrier and planet bearing clearance, gravity, and tangential pin position error, is also investigated. The combined effect of gravity and carrier bearing clearance was primarily responsible for unequal load sharing. Reducing carrier bearing clearance significantly improved load sharing, while reducing planet clearance did not. Normal tangential pin position error did not impact load sharing due to the floating sun design of this three-planet gearbox.

17 WIND ENERGY↗

Measurement of angular distribution of sound emission from training projectiles in subsonic flight

Training projectiles with nose ring cavities that produce intense whistles in stationary free-jet tests were shot in a relatively straight-line trajectory. A ground based microphone was used to obtain the angular distribution of sound intensity produced from the subsonically flying projectile. Data reduction required calculation of Doppler and attenuation factors which were determined based on a non-linear trajectory. Also, the directional sensitivity of the microphone was measured and used in the data reduction. Significant angular variation of sound intensity produced from the projectile was found which can be used to plot an intensity contour map on the ground. A full-scale field test confirmed the validity of the aeroacoustic concept of producing a relatively intense whistle from the projectile, and the usefulness of a real-time data acquisition system.

Cho, Y. I.↗

Tilted lidar profiling: Development and testing of a novel scanning strategy for inhomogeneous flows

The most common profiling techniques for the atmospheric boundary layer based on a monostatic Doppler wind lidar rely on the assumption of horizontal homogeneity of the flow. This assumption breaks down in the presence of either natural or human-made obstructions that can generate significant flow distortions. The need to deploy ground-based lidars near operating wind turbines for the American WAKE experimeNt (AWAKEN) spurred a search for novel profiling techniques that could avoid the influence of the flow modifications caused by the wind farms. With this goal in mind, two well-established profiling scanning strategies have been retrofitted to scan in a tilted fashion and steer the beams away from the more severely inhomogeneous region of the flow. Results from a field test at the National Renewable Energy Laboratory's 135-m meteorological tower show that the accuracy of the horizontal mean flow reconstruction is insensitive to the tilt of the scan, although higher-order wind statistics are severely deteriorated at extreme tilts mainly due to geometrical error amplification. A numerical study of the AWAKEN domain based on the Weather Research and Forecasting Model and large-eddy simulation are also conducted to test the effectiveness of tilted profiling. It is shown that a threefold reduction of the error on inflow mean wind speed can be achieved for a lidar placed at the base of the turbine using tilted profiling.

17 WIND ENERGY↗

Field evaluation of transgenic hybrid poplars with desirable wood properties and enhanced growth for biofuel production by bicistronic expression of PdGA20ox1 and PtrMYB3 in wood-forming tissue

Background: To create an ideotype woody bioenergy crop with desirable growth and biomass properties, we utilized the viral 2A-meidated bicistronic expression strategy to express both PtrMYB3 ( MYB46 ortholog of Populus trichocarpa , a master regulator of secondary wall biosynthesis) and PdGA20ox1 (a GA20-oxidase from Pinus densiflora that produces gibberellins) in wood-forming tissue (i.e., developing xylem). Results: Transgenic Arabidopsis plants expressing the gene construct DX15::PdGA20ox1-2A-PtrMYB3 showed a significant increase in both stem fresh weight (threefold) and secondary wall thickening (1.27-fold) relative to wild-type (WT) plants. Transgenic poplars harboring the same gene construct grown in a greenhouse for 60 days had a stem fresh weight up to 2.6-fold greater than that of WT plants. In a living modified organism (LMO) field test conducted for 3 months of active growing season, the stem height and diameter growth of the transgenic poplars were 1.7- and 1.6-fold higher than those of WT plants, respectively, with minimal adverse growth defects. Although no significant changes in secondary wall thickening of the stem tissue of the transgenic poplars were observed, cellulose content was increased up to 14.4 wt% compared to WT, resulting in improved saccharification efficiency of the transgenic poplars. Moreover, enhanced woody biomass production by the transgenic poplars was further validated by re-planting in the same LMO field for additional two growing seasons. Conclusions: Taken together, these results show considerably enhanced wood formation of our transgenic poplars, with improved wood quality for biofuel production.

09 BIOMASS FUELS↗

Analysis of Dust and Corrosion Witness Samples Recovered from SNF Dry Storage Systems, Maine Yankee, 2023

This report documents the results of a long-term (5.79 year) exposure of 4-point bend corrosion test samples in the inlet and outlet vents of four spent nuclear fuel dry storage systems at the Maine Yankee Independent Spent Fuel Storage Installation. The goal of the test was to evaluate the corrosiveness of salt aerosols in a realistic near-marine environment, providing a data set for improved understanding of stress corrosion cracking of spent nuclear fuel dry storage canisters. Examination of the samples after extraction showed minor corrosion was present, mostly on rough-ground surfaces. However, dye penetrant testing showed that no SCC cracks were present. Dust collected on coupons co-located with the corrosion specimens was analyzed by scanning electron microscopy and leached to determine the soluble salts present. The dust was mostly organic material (pollen and stellate trichomes), with lesser detrital mineral grains. Salts present were a mix of sea-salts and continental salts, with chloride dominating the anions, but significant amounts of nitrate were also present. Both corrosion samples and dust samples showed evidence of wetting, indicating entry of water into the vents. The results of this field test suggest that the environment at Maine Yankee is not highly aggressive, although extrapolation from the periodically wetted vent samples to the hot, dry, canister surface may be difficult. No stress corrosion cracks were observed, but minor corrosion was present despite high nitrate concentrations in the salts. These observations may help address the ongoing question of the importance of nitrate in suppressing corrosion and SCC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of a Hydroxyapatite Permeable Reactive Barrier to Remediate Uranium at the Old Rifle Site Colorado.

We have performed an initial evaluation and testing program to assess the effectiveness of a hydroxyapatite (Ca10(PO4)6(OH)2) permeable reactive barrier and source area treatment to decrease uranium mobility at the Department of Energy (DOE) former Old Rifle uranium mill processing site in Rifle, western Colorado. Uranium ore was processed at the site from the 1940s to the 1970s. The mill facilities at the site as well as the uranium mill tailings previously stored there have all been removed. Groundwater in the alluvial aquifer beneath the site still contains elevated concentrations of uranium, and is currently used for field tests to study uranium behavior in groundwater and investigate potential uranium remediation technologies. The technology investigated in this work is based on in situ formation of apatite in sediment to create a subsurface apatite PRB and also for source area treatment. The process is based on injecting a solution containing calcium citrate and sodium into the subsurface for constructing the PRB within the uranium plume. As the indigenous sediment micro-organisms biodegrade the injected citrate, the calcium is released and reacts with the phosphate to form hydroxyapatite (precipitate). This paper reports on proof-of-principle column tests with Old Rifle sediment and synthetic groundwater.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lunar Water Resource Demonstration (LWRD) Test Results

NASA has undertaken the In-Situ Resource Utilization (lSRU) project called RESOLVE (Regolith and Environment Science & Oxygen and Lunar Volatile Extraction). This project is an Earth-based lunar precursor demonstration of a system that could be sent to explore permanently shadowed polar lunar craters, where it would drill into regolith, quantify the volatiles that are present, and extract oxygen by hydrogen reduction of iron oxides. The RESOLVE chemical processing system was mounted within the CMU rover "Scarab" and successfully demonstrated on Hawaii's Mauna Kea volcano in November 2008. This technology could be used on Mars as well. As described at the 2008 Mars Society Convention, the Lunar Water Resource Demonstration (LWRD) supports the objectives of the RESOLVE project by capturing and quantifying water and hydrogen released by regolith upon heating. Field test results for the quantification of water using LWRD showed that the volcanic ash (tephra) samples contained 0.15-0.41% water, in agreement with GC water measurements. Reduction of the RH in the surge tank to near zero during recirculation show that the water is captured by the water beds as desired. The water can be recovered by heating the Water Beds to 230 C or higher. Test results for the capture and quantification of pure hydrogen have shown that over 90% of the hydrogen can be captured and 98% of the absorbed hydrogen can be recovered upon heating the hydride to 400 C and desorbing the hydrogen several times into the evacuated surge tank. Thus, the essential requirement of capturing hydrogen and recovering it has been demonstrated. ,

Muscatello, Anthony C.↗

A source-synchronous filter for uncorrelated receiver traces from a swept-frequency seismic source

We have developed a novel algorithm to reduce noise in signals obtained from swept-frequency sources by removing out-of-band external noise sources and distortion caused from unwanted harmonics. The algorithm is designed to condition nonstationary signals for which traditional frequency-domain methods for removing noise have been less effective. The source synchronous filter (SSF) is a time-varying narrow band filter, which is synchronized with the frequency of the source signal at all times. Because the bandwidth of the filter needs to account for the source-to-receiver propagation delay and the sweep rate, SSF works best with slow sweep rates and moveout-adjusted waveforms to compensate for source-receiver delays. The SSF algorithm was applied to data collected during a field test at the University of California Santa Barbara’s Garner Valley downhole array site in Southern California. At the site, a 45 kN shaker was mounted on top of a one-story structure and swept from 0 to 10 Hz and back over 60 s (producing useful seismic waves greater than 1.6 Hz). The seismic data were captured with small accelerometer and geophone arrays and with a distributed acoustic sensing array, which is a fiber-optic-based technique for the monitoring of elastic waves. The result of the application of SSF on the field data is a set of undistorted and uncorrelated traces that can be used in different applications, such as measuring phase velocities of surface waves or applying convolution operations with the encoder source function to obtain traveltimes. Lastly, the results from the SSF were used with a visual phase alignment tool to facilitate developing dispersion curves and as a prefilter to improve the interpretation of the data.

58 GEOSCIENCES↗

Radioxenon Detection for Monitoring Subsurface Nuclear Explosion

The Comprehensive Nuclear-Test-Ban Treaty (CTBT) bans the testing of nuclear weapons anywhere on the earth (atmospheric, surface, underwater and subsurface). Identification of nuclear explosions in the atmosphere, surface, and underwater is relatively straightforward considering a wide range of signatures resulting from such an event. However, for a subsurface explosion, most of the signatures traditionally associated with a nuclear explosion are not readily available. Therefore, the international community has increasingly relied on the atmospheric measurement of noble gases to identify subsurface nuclear weapon explosions. This chapter initially covers the basic principles of subsurface nuclear explosion identification and the importance of detecting radioxenon. This is followed by reviewing some of the early radioxenon detection systems that were developed by research groups around the world in the late 1990s and early 2000s. The detection media employed, results from laboratory and field testing, and some challenges/drawbacks for these systems are detailed. The next section of the chapter is dedicated to innovative detector concepts that have emerged in the past ten to fifteen years using novel detection material, algorithms, and signal readout techniques. The advances achieved in terms of energy resolution, coincidence detection efficiencies, system performance, and the minimum detectable concentration are covered. The final section goes over some of the potential improvements that can be incorporated in the design to enhance detector sensitivity and new detection material that can be explored in the field of radioxenon detection.

Gadey, Harish Reddy↗

Dose-to-water conversion for the backscatter-shielded EPID: A frame-based method to correct for EPID energy response to MLC transmitted radiation

Purpose: To develop a frame-by-frame correction for the energy response of amorphous silicon electronic portal imaging devices (a-Si EPIDs) to radiation that has transmitted through the multileaf collimator (MLC) and to integrate this correction into the backscatter shielded EPID (BSS-EPID) dose-to-water conversion model. Methods: Individual EPID frames were acquired using a Varian frame grabber and iTools acquisition software then processed using in-house software developed inMATLAB. For each EPID image frame, the region below the MLC leaves was identified and all pixels in this region were multiplied by a factor of 1.3 to correct for the under-response of the imager to MLC transmitted radiation. The corrected frames were then summed to form a corrected integrated EPID image. This correction was implemented as an initial step in the BSS-EPID dose-to-water conversion model which was then used to compute dose planes in a water phantom for 35 IMRT fields. The calculated dose planes, with and without the proposed MLC transmission correction, were compared to measurements in solid water using a two-dimensional diode array. Results: It was observed that the integration of the MLC transmission correction into the BSS-EPID dose model improved agreement between modeled and measured dose planes. In particular, the MLC correction produced higher pass rates for almost all Head and Neck fields tested, yielding an average pass rate of 99.8% for 2%/2 mm criteria. A two-sample independentt-test and fisher F-test were used to show that the MLC transmission correction resulted in a statistically significant reduction in the mean and the standard deviation of the gamma values, respectively, to give a more accurate and consistent dose-to-water conversion. Conclusions: The frame-by-frame MLC transmission response correction was shown to improve the accuracy and reduce the variability of the BSS-EPID dose-to-water conversion model. The correction may be applied as a preprocessing step in any pretreatment portal dosimetry calculation and has been shown to be beneficial for highly modulated IMRT fields.

60 APPLIED LIFE SCIENCES↗

Imaging LIDAR through Fog and Dust for Maritime Surveillance

This work supports Airborne Intelligence, Surveillance, and Reconnaissance (ISR) for tactical situational awareness in challenging environments with modified imaging LIDAR (light detection and ranging). LIDAR produces an irradiance-based scene with high, three-dimensional, spatial resolution; differentiating reflecting surfaces and surface textures not just for target detection, but also target recognition. LIDAR is generally prevented from working through all weather; as the traditional source wavelengths are scattered and/or absorbed by fog, clouds, and dust known as degraded visual environments (DVEs). This work identifies and quantifies improved optical wavelength regimes and polarization strategies that should open this otherwise denied operating window for LIDAR. We demonstrate modified imaging LIDAR's utility and ability to produce images in environments that have been challenging for traditional LIDAR (fog, dust) systems. We utilize a state-of-the-art Geiger mode avalanche photodiode (GMAPD) 32X32 detecting array for imaging with an integrated fast timing circuit ROIC per imaging detector pixel. This GMAPD is equivalent to 1024 radar receivers and produces a 3-D point cloud scene for each <lnsec laser interrogation pulse. Through this work, we have demonstrated Sandia's first imaging LIDAR system. We developed significant software to scan the GMAPD array, control data acquisition, and stitch an arbitrary number of images for greater lateral spatial resolution. We designed and built an optical system to evaluate performance, in the laboratory and in field tests, and relate to the performance at tactically important distances. Our use of this system is to study and characterize techniques that extend the range of useful imaging through fog for applications in a maritime environment. We quantify, with simulations, broad wavelength regimes and illuminating polarizations that have benefit in propagating through fog. In particular, we identify circular polarization over broad wavebands as a superior persisting signal technique in extending the useful range of active LIDAR in forward-scattering environments. Finally, we characterize the performance of our LIDAR system and confirm our theoretical predictions in the field and directly evaluate this system as a function of polarization in Sandia's medium-range Fog Tunnel Facility. This technology has potential impacts in improved ISR in maritime environments, but with further development could be revolutionary in tactical ISR by providing real-time three-dimensional full motion video (3D FMV) in DVEs.

47 OTHER INSTRUMENTATION↗

Predicting the Consequences of Workload Management Strategies with Human Performance Modeling

Human performance modelers at the US Army Research Laboratory have developed an approach for establishing Soldier high workload that can be used for analyses of proposed system designs. Their technique includes three key components. To implement the approach in an experiment, the researcher would create two experimental conditions: a baseline and a design alternative. Next they would identify a scenario in which the test participants perform all their representative concurrent interactions with the system. This scenario should include any events that would trigger a different set of goals for the human operators. They would collect workload values during both the control and alternative design condition to see if the alternative increased workload and decreased performance. They have successfully implemented this approach for military vehicle. designs using the human performance modeling tool, IMPRINT. Although ARL researches use IMPRINT to implement their approach, it can be applied to any workload analysis. Researchers using other modeling and simulations tools or conducting experiments or field tests can use the same approach.

Mitchell, Diane Kuhl↗

SU-F-T-216: Evaluating Dosimetry Accuracy of a Treatment Planning System On Small Proton Fields

Purpose: This study is aiming to identify the smallest field size for which a treatment planning system (TPS) can accurately calculate the relative dose distribution. The finding would be used as a guideline to choose the smallest proton field for clinical treatment. Methods: Mevion S250™ double scattering proton delivery system and Eclipse™ TPS (Varian) with pencil beam convolution (PBC) dose algorithm were used in this study. Square sized fields of 1 cm, 2 cm, 3 cm, 4 cm, 5 cm, and 10 cm were planned on a cubical water phantom with iso-center placed at 10 cm depth. All beams used the same proton beam option: range 15 cm and modulation 10 cm. Dose in water was calculated without any compensator. Gafchromic™ EBT3 film and diode detectors were used to measure the central axis dose distribution and lateral dose profiles at 5 cm, 10 cm, and 14 cm depth. Results: The preliminary film measurement shows good agreement between Eclipse calculated lateral dose profiles for all tested field sizes. The differences on full width half maximum were ≤ 1 mm while the differences on the penumbras were between 1 mm and 2 mm between Eclipse and film. For the depth dose, Eclipse results matched well with film measurements for field sizes down to 2 cm{sup 2}. With smaller field size of 1 cm{sup 2}, Eclipse was able to predict the decreasing of SOBP due to the lack of lateral charged particle equilibrium in depth. However, it did not match the film measurement. Diode measurement results will be available at the time of presentation. Conclusion: The PBC dose algorithm in Eclipse can accurately calculate relative dose distribution in double scattered proton system for field size down to 2 cm{sup 2}.

60 APPLIED LIFE SCIENCES↗

A Topographical Lidar System for Terrain-Relative Navigation

An imaging lidar system is being developed for use in navigation, relative to the local terrain. This technology will potentially be used for future spacecraft landing on the Moon. Systems like this one could also be used on Earth for diverse purposes, including mapping terrain, navigating aircraft with respect to terrain and military applications. The system has been field-tested aboard a helicopter in the Mojave Desert. When this system was designed, digitizers with sufficient sampling rate (2 GHz) were only available with very limited memory. Also, it was desirable to limit the amount of data to be transferred between the digitizer and the mass storage between individual frames. One of the novelty design features of this system was to design the system around the limited amount of memory of the digitizer. The system is required to operate over an altitude (distance) range from a few meters to approximately 1 km, but for each scan across the full field of view, the digitizer memory is only able to hold data for an altitude range no more than 100 m. Data acquisition methods in support of the limited 100 m wide altitude range are described.

Liebe, Carl Christian↗

In-Containment Signal Acquisition and Data Transmission via Power Lines within High Dose Areas of Nuclear Power Plants

Signal acquisition and data transmission for innovative sensor systems and networks inside the containment of nuclear power plants (NPPs) is still a challenge with respect to safety, performance, reliability, availability, and costs. This especially applies to equipment upgrades for existing plants, special measurements, but also for new builds. This paper presents a novel method for efficient and cost-effective sensor signal acquisition and data transmission via power lines, in order to cope with the disadvantages of common system architectures that often suffer from poor signal integrity due to raw data transmissions via long cables, huge efforts and costs for installation, and low flexibility with respect to maintenance and upgrades. A transmitter-receiver architecture is proposed that allows multiplexing of multiple sensor inputs for unidirectional point-to-point transmission by superimposing information signals on existing AC or DC supply lines, but also on active and inactive sensor wires, or spare cables, using power line communication (PLC) technology. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter hardware is designed to operate in harsh environment within the containment during full plant operation. The system's modular approach allows application specific trade-offs between redundancy and throughput regarding data transmission, as well as various sensor input front-ends which are compatible with state of the art systems. PLC technology eliminates the need for costly installation of additional cables and wall penetrations, while providing a complementary and diverse communication technology for upgrades of existing systems. At the receiver side in low dose areas, signals are extracted from the power line, demodulated, and de-multiplexed, in order to regain the original sensor signal information and provide it either in analog or digital output format. Successful laboratory qualification tests, field trails, and a demonstrator setup installation within a NPP verify the overall performance of the proposed system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reliability of Open Public Electric Vehicle Direct Current Fast Chargers

The aim was to systematically evaluate the usability of all public electric vehicles (EV) direct current fast chargers (DCFC) in the San Francisco region. To achieve a rapid transition to EVs, a highly reliable and easy to use charging infrastructure is critical to building confidence among consumers. The functionality and usability of all 182 open, public DCFC charging stations with CCS connectors (combined charging system) in the 9 counties of the Bay Area were tested (655 electric vehicle service equipment (EVSE) ports). An EVSE was classified as functional if it charged an EV for 2 minutes. Overall, 73.3% of the 655 EVSEs were functional. The causes of the nonfunctioning EVSEs (23.5%) were blank or unresponsive screens or error messages; payment system failures; charge initiation failures; network failures; or broken connectors. In addition, the cable was too short to reach the EV inlet for 3.2% of the EVSEs. A random sampling of 10% of the EVSEs, approximately 8 days after the first evaluation, found no overall change in functionality. The level of functionality found with field testing conflicts with the 95–98% uptime reported by the EV service providers (EVSPs) who operate the EV charging stations. There is a need for precise and verifiable definitions of uptime, downtime, and excluded time, as applied to public EV chargers. In conclusion, the level of failure of the existing public EV DCFC charge infrastructure highlights the importance of improving the system design and maintenance to improve adoption of EVs.

33 ADVANCED PROPULSION SYSTEMS↗