Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

The Second Skin: A Wearable Sensor Suite that Enables Real-Time Human Biomechanics Tracking Through Deep Learning

Objective: Real-time determination of human kinematics and kinetics could advance biomechanics research and enable valuable applications of biofeedback and generalizable exoskeleton control. Here, this work aims to investigate a taskindependent, user-independent method for obtaining precise realtime joint state estimation across lower-body joints during a wide variety of tasks. Methods: We developed a generalizable sensing approach using a suit comprised of inertial measurement units (IMUs) and pressure insoles. With the suit, we collected a dataset of 33 tasks commonly performed during construction and hazardous waste cleanup (N = 10). We then trained deep learning user-independent, task-agnostic models to estimate joint lowerbody kinematics and dynamics using only worn sensor data. We likewise computed joint kinematics and dynamics analytically from sensor data to serve as a comparison tool for model results. Results: Our models achieved overall angle estimation root-meansquared-errors (RMSE) of 6.56±.92°, 8.60±1.01°, 7.58±.89°, and 6.00±.73° compared to 13.9±.1.3°, 15.31±1.0°, 10.76±.70°, and 7.56±.48° via analytical methods at the lower back, hip, knee, and ankle, respectively. Likewise, our models achieved overall normalized moment estimation RMSEs of .207±.069 Nm/kg, .242±.044 Nm/kg, .202±.038 Nm/kg, and .193±.034 Nm/kg compared to .306±.036 Nm/kg, .407±.021 Nm/kg, 1.18 ±.022 Nm/kg, and 1.73±.071 Nm/kg via analytical methods at the lower back, hip, knee, and ankle, respectively. Conclusion: These results are comparable to other state-of-the-art wearable sensing systems, establishing deep learning as a viable sensing approach that generalizes to new users and tasks. Significance: This work shows promise for enabling accurate real-world biomechanical data collection and enhancement of biofeedback systems and wearable robot control.

Casey, Ryan T. F. [Georgia Institute of Technology↗

Accuracy of Ultrasound-Based Image Guidance for Daily Positioning of the Upper Abdomen: An Online Comparison With Cone Beam CT

Purpose: Image-guided intensity-modulated radiotherapy can improve protection of organs at risk when large abdominal target volumes are irradiated. We estimated the daily positioning accuracy of ultrasound-based image guidance for abdominal target volumes by a direct comparison of daily imaging obtained with cone beam computed tomography (CBCT). Methods and Materials: Daily positioning (n = 83 positionings) of 15 patients was completed by using ultrasound guidance after an initial CBCT was obtained. Residual error after ultrasound was estimated by comparison with a second CBCT. Ultrasound image quality was visually rated using a scale of 1 to 4. Results: Of 15 patients, 7 patients had good sonographic imaging quality, 5 patients had satisfactory sonographic quality, and 3 patients were excluded because of unsatisfactory sonographic quality. When image quality was good, residual errors after ultrasound were -0.1 {+-} 3.11 mm in the x direction (left-right; group systematic error M = -0.09 mm; standard deviation [SD] of systematic error, {sigma} = 1.37 mm; SD of the random error, {sigma} = 2.99 mm), 0.93 {+-} 4.31 mm in the y direction (superior-inferior, M = 1.12 mm; {sigma} = 2.96 mm; {sigma} = 3.39 mm), and 0.71 {+-} 3.15 mm in the z direction (anteroposterior; M = 1.01 mm; {sigma} = 2.46 mm; {sigma} = 2.24 mm). For patients with satisfactory image quality, residual error after ultrasound was -0.6 {+-} 5.26 mm in the x (M = 0.07 mm; {sigma} = 5.67 mm; {sigma} = 4.86 mm), 1.76 {+-} 4.92 mm in the y (M = 3.54 mm; {sigma} = 4.1 mm; {sigma} = 5.29 mm), and 1.19 {+-} 4.75 mm in the z (M = 0.82 mm; {sigma} = 2.86 mm; {sigma} = 3.05 mm) directions. Conclusions: In patients from whom good sonographic image quality could be obtained, ultrasound improved daily positioning accuracy. In the case of satisfactory image quality, ultrasound guidance improved accuracy compared to that of skin marks only minimally. If sonographic image quality was unsatisfactory, daily CBCT scanning improved treatment accuracy distinctly over that of ultrasound. Use of daily ultrasound or CBCT imaging can help to reduce PTV margins and protect organs at risk compared to the use of skin mark-based positioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Improved Algorithm for Estimating Surface Shortwave Radiation: Preliminary Evaluation With MODIS Products

Cloud parameters, as key inputs in radiative transfer algorithms, have a critical impact on surface shortwave radiation (SSR) computation. By introducing a parameterization of cloud transmittance and reflectance, based on radiative transfer simulations, this study improves the accuracy of an existing physically based model which severely underestimates SSR under thick cloud conditions. The cloud parameterization adopts the single-layer cloud model and simulates cloud transmittances and reflectances by varying cloud optical thickness, cloud particle size, and solar zenith angle. The revised model is applied to estimate instantaneous SSR using Moderate-resolution Imaging Spectroradiometer (MODIS) atmospheric and land products. The retrieved SSR is evaluated against observation data from 41 Baseline Surface Radiation Network (BSRN) stations and is also compared with the MODIS official SSR product. The root mean square error (RMSE) of the estimated instantaneous radiation is approximately 52 and 98 W m -2 under clear-sky and all-sky conditions, respectively. The accuracy of the improved parameterization is higher than that of the original model, and there is no obvious underestimation of SSR in the case of high cloud optical thickness. Therefore, the new algorithm improves the accuracy of SSR estimates in the presence of thick clouds. Retrievals with the improved model also achieve higher accuracy than the MODIS official SSR product (MCD18A1). To conclude, the reliable performance of the scheme at most BSRN stations illustrates that the improved model can be used to map SSR on a global scale.

42 ENGINEERING↗

Bayesian Inference for the Seismic Moment Tensor Using Regional Waveforms and Teleseismic- P Polarities with a Data-Derived Distribution of Velocity Models and Source Locations

The largest source of uncertainty in any source inversion is the velocity model used in the transfer function that relates observed ground motion to the seismic moment tensor. However, standard inverse procedure often does not quantify uncertainty in the seismic moment tensor due to error in the Green’s functions from uncertain event location and Earth structure. Here, we incorporate this uncertainty into an estimation of the seismic moment tensor using a data-derived distribution of velocity models based on complementary geophysical data sets, including thickness constraints, velocity profiles, gravity data, surface-wave group velocities, and regional body-wave travel times. The data-derived distribution of velocity models is then used as a prior distribution of Green’s functions for use in Bayesian inference of an unknown seismic moment tensor using regional and teleseismic-P waveforms. The use of multiple data sets is important for gaining resolution to different components of the moment tensor. The combined likelihood is estimated using data-specific error models and the posterior of the seismic moment tensor is estimated and interpreted in terms of the most probable source type.

58 GEOSCIENCES↗

Spatial frequency spectrum of the x-ray scatter distribution in CBCT projections

Purpose: X-ray scatter is a source of significant image quality loss in cone-beam computed tomography (CBCT). The use of Monte Carlo (MC) simulations separating primary and scattered photons has allowed the structure and nature of the scatter distribution in CBCT to become better elucidated. This work seeks to quantify the structure and determine a suitable basis function for the scatter distribution by examining its spectral components using Fourier analysis.Methods: The scatter distribution projection data were simulated using a CBCT MC model based on the EGSnrc code. CBCT projection data, with separated primary and scatter signal, were generated for a 30.6 cm diameter water cylinder [single angle projection with varying axis-to-detector distance (ADD) and bowtie filters] and two anthropomorphic phantoms (head and pelvis, 360 projections sampled every 1°, with and without a compensator). The Fourier transform of the resulting scatter distributions was computed and analyzed both qualitatively and quantitatively. A novel metric called the scatter frequency width (SFW) is introduced to determine the scatter distribution's frequency content. The frequency content results are used to determine a set basis functions, consisting of low-frequency sine and cosine functions, to fit and denoise the scatter distribution generated from MC simulations using a reduced number of photons and projections. The signal recovery is implemented using Fourier filtering (low-pass Butterworth filter) and interpolation. Estimates of the scatter distribution are used to correct and reconstruct simulated projections.Results: The spatial and angular frequencies are contained within a maximum frequency of 0.1 cm{sup −1} and 7/(2π) rad{sup −1} for the imaging scenarios examined, with these values varying depending on the object and imaging setup (e.g., ADD and compensator). These data indicate spatial and angular sampling every 5 cm and π/7 rad (∼25°) can be used to properly capture the scatter distribution, with reduced sampling possible depending on the imaging scenario. Using a low-pass Butterworth filter, tuned with the SFW values, to denoise the scatter projection data generated from MC simulations using 10{sup 6} photons resulted in an error reduction of greater than 85% for the estimating scatter in single and multiple projections. Analysis showed that the use of a compensator helped reduce the error in estimating the scatter distribution from limited photon simulations by more than 37% when compared to the case without a compensator for the head and pelvis phantoms. Reconstructions of simulated head phantom projections corrected by the filtered and interpolated scatter estimates showed improvements in overall image quality.Conclusions: The spatial frequency content of the scatter distribution in CBCT is found to be contained within the low frequency domain. The frequency content is modulated both by object and imaging parameters (ADD and compensator). The low-frequency nature of the scatter distribution allows for a limited set of sine and cosine basis functions to be used to accurately represent the scatter signal in the presence of noise and reduced data sampling decreasing MC based scatter estimation time. Compensator induced modulation of the scatter distribution reduces the frequency content and improves the fitting results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A PARALLAX DISTANCE AND MASS ESTIMATE FOR THE TRANSITIONAL MILLISECOND PULSAR SYSTEM J1023+0038

The recently discovered transitional millisecond pulsar system J1023+0038 exposes a crucial evolutionary phase of recycled neutron stars for multiwavelength study. The system, comprising the neutron star itself, its stellar companion, and the surrounding medium, is visible across the electromagnetic spectrum from the radio to X-ray/gamma-ray regimes and offers insight into the recycling phase of millisecond pulsar evolution. Here, we report on multiple-epoch astrometric observations with the Very Long Baseline Array (VLBA) which give a system parallax of 0.731 {+-} 0.022 milliarcseconds (mas) and a proper motion of 17.98 {+-} 0.05 mas yr{sup -1}. By combining our results with previous optical observations, we are able to use the parallax distance of 1368{sup +42}{sub -{sub 39}} pc to estimate the mass of the pulsar to be 1.71 {+-} 0.16 M{sub Sun }, and we are also able to measure the three-dimensional space velocity of the system to be 126 {+-} 5 km s{sup -1}. Despite the precise nature of the VLBA measurements, the remaining {approx}3% distance uncertainty dominates the 0.16 M{sub Sun} error on our mass estimate.

79 ASTRONOMY AND ASTROPHYSICS↗

Projection of a Measurement of the Nonphotonic Electron v2 in Au+Au Collisions at STAR

We present a method of measuring the elliptic flow (v{sub 2}) of nonphotonic electrons from heavy flavor quark decays using the STAR detector at RHIC in Au + Au collisions at {radical}S{sub NN}. Inclusive electrons are identified in the p{sub T} range 0.5-4 GeV/c at mid-rapidity -1 < {eta} < 0 by the STAR time projection chamber (TPC) and time-of-flight detector. Photonic e{sup +}e{sup -} pairs with characteristic low invariant mass are reconstructed in the TPC and their v{sub 2} is measured using the standard event plane method by subtracting the combinatorial background in the dN/d{Delta}{phi} distributions in each p{sub T} bin. The nonphotonic electron v{sub 2} and its propagated error can be derived from the inclusive and photonic electron v{sub 2}. We estimate the necessary statistics and errors of nonphotonic electron v{sub 2} for a more recent RHIC run.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Estimating traffic volumes for signalized intersections using connected vehicle data

Recently connected vehicle (CV) technology has received significant attention thanks to active pilot deployments supported by the US Department of Transportation (USDOT). At signalized intersections, CVs may serve as mobile sensors, providing opportunities of reducing dependencies on conventional vehicle detectors for signal operation. However, most of the existing studies mainly focus on scenarios that penetration rates of CVs reach certain level, e.g., 25%, which may not be feasible in the near future. How to utilize data from a small number of CVs to improve traffic signal operation remains an open question. In this work, we develop an approach to estimate traffic volume, a key input to many signal optimization algorithms, using GPS trajectory data from CV or navigation devices under low market penetration rates. To estimate traffic volumes, we model in this paper vehicle arrivals at signalized intersections as a time-dependent Poisson process, which can account for signal coordination. The estimation problem is formulated as a maximum likelihood problem given multiple observed trajectories from CVs approaching to the intersection. An expectation maximization (EM) procedure is derived to solve the estimation problem. Two case studies were conducted to validate our estimation algorithm. One uses the CV data from the Safety Pilot Model Deployment (SPMD) project, in which around 2800 CVs were deployed in the City of Ann Arbor, MI. The other uses vehicle trajectory data from users of a commercial navigation service in China. Mean absolute percentage error (MAPE) of the estimation is found to be 9–12%, based on benchmark data manually collected and data from loop detectors. Finally, considering the existing scale of CV deployments, the proposed approach could be of significant help to traffic management agencies for evaluating and operating traffic signals, paving the way of using CVs for detector-free signal operation in the future.

97 MATHEMATICS AND COMPUTING↗

Effects of finite sampling on fatigue damage estimation of wind turbine components: A statistical study

The variability of the wind turbine loads complicates fatigue assessment in the design phase, as performing simulations covering the entire lifetime is computationally expensive. The current work provides important information for assessing the uncertainty in fatigue damage estimation due to finite data. Here we study the sample size effect on mean, variance, and skewness of damage in each wind bin, identify the important wind bins, and study the uncertainty propagation from each wind bin to the lifetime damage using 3600 aeroelastic simulations and bootstrapping. To achieve less than 1% error in the damage estimation across all load channels in the current case study, at least 100 turbulence seeds are needed. Damage in different wind bins follows a lognormal distribution when using the conventional approach of six seeds. The provided insights and information allow the designer to achieve a specific level of accuracy for a given computational cost using strategic bin sampling.

17 WIND ENERGY↗

Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images

Purpose: Applications of cone-beam CT (CBCT) to image-guided radiation therapy (IGRT) are hampered by shading artifacts in the reconstructed images. These artifacts are mainly due to scatter contamination in the projections but also can result from uncorrected beam hardening effects as well as nonlinearities in responses of the amorphous silicon flat panel detectors. While currently, CBCT is mainly used to provide patient geometry information for treatment setup, more demanding applications requiring high-quality CBCT images are under investigation. To tackle these challenges, many CBCT correction algorithms have been proposed; yet, a standard approach still remains unclear. In this work, we propose a shading correction method for CBCT that addresses artifacts from low-frequency projection errors. The method is consistent with the current workflow of radiation therapy. Methods: With much smaller inherent scatter signals and more accurate detectors, diagnostic multidetector CT (MDCT) provides high quality CT images that are routinely used for radiation treatment planning. Using the MDCT image as ''free'' prior information, we first estimate the primary projections in the CBCT scan via forward projection of the spatially registered MDCT data. Since most of the CBCT shading artifacts stem from low-frequency errors in the projections such as scatter, these errors can be accurately estimated by low-pass filtering the difference between the estimated and raw CBCT projections. The error estimates are then subtracted from the raw CBCT projections. Our method is distinct from other published correction methods that use the MDCT image as a prior because it is projection-based and uses limited patient anatomical information from the MDCT image. The merit of CBCT-based treatment monitoring is therefore retained. Results: The proposed method is evaluated using two phantom studies on tabletop systems. On the Catphan(c)600 phantom, our approach reduces the reconstruction error from 348 Hounsfield unit (HU) without correction to 4 HU around the object center after correction, and from 375 HU to 17 HU in the high-contrast regions. In the selected regions of interest (ROIs), the average image contrast is increased by a factor of 3.3. When noise suppression is implemented, the proposed correction substantially improves the contrast-to-noise ratio (CNR) and therefore the visibility of low-contrast objects, as seen in a more challenging pelvis phantom study. Besides a significant improvement in image uniformity, a low-contrast object of {approx}25 HU, which is otherwise buried in the shading artifacts, can be clearly identified after the proposed correction due to a CNR increase of 3.1. Compared to a kernel-based scatter correction method coupled with an analytical beam hardening correction, our approach also shows an overall improved performance with some residual artifacts. Conclusions: By providing effective shading correction, our approach has the potential to improve the accuracy of more advanced CBCT-based clinical applications for IGRT, such as tumor delineation and dose calculation.

60 APPLIED LIFE SCIENCES↗

Treatment planning for prostate focal laser ablation in the face of needle placement uncertainty

Purpose: To study the effect of needle placement uncertainty on the expected probability of achieving complete focal target destruction in focal laser ablation (FLA) of prostate cancer. Methods: Using a simplified model of prostate cancer focal target, and focal laser ablation region shapes, Monte Carlo simulations of needle placement error were performed to estimate the probability of completely ablating a region of target tissue. Results: Graphs of the probability of complete focal target ablation are presented over clinically relevant ranges of focal target sizes and shapes, ablation region sizes, and levels of needle placement uncertainty. In addition, a table is provided for estimating the maximum target size that is treatable. The results predict that targets whose length is at least 5 mm smaller than the diameter of each ablation region can be confidently ablated using, at most, four laser fibers if the standard deviation in each component of needle placement error is less than 3 mm. However, targets larger than this (i.e., near to or exceeding the diameter of each ablation region) require more careful planning. This process is facilitated by using the table provided. Conclusions: The probability of completely ablating a focal target using FLA is sensitive to the level of needle placement uncertainty, especially as the target length approaches and becomes greater than the diameter of ablated tissue that each individual laser fiber can achieve. The results of this work can be used to help determine individual patient eligibility for prostate FLA, to guide the planning of prostate FLA, and to quantify the clinical benefit of using advanced systems for accurate needle delivery for this treatment modality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

BeyondPlanck: XII. Cosmological parameter constraints with end-to-end error propagation

We present cosmological parameter constraints estimated using the Bayesian BEYONDPLANCK analysis framework. This method supports seamless end-to-end error propagation from raw time-ordered data onto final cosmological parameters. As a first demonstration of the method, we analyzed time-ordered Planck LFI observations, combined with selected external data (WMAP 33–61 GHz, Planck HFI DR4 353 and 857 GHz, and Haslam 408 MHz) in the form of pixelized maps that are used to break critical astrophysical degeneracies. Overall, all the results are generally in good agreement with previously reported values from Planck 2018 and WMAP, with the largest relative difference for any parameter amounting about 1σ when considering only temperature multipoles between 30 ≤ ℓ ≤ 600. In cases where there are differences, we note that the BEYONDPLANCK results are generally slightly closer to the high-ℓ HFI-dominated Planck 2018 results than previous analyses, suggesting slightly less tension between low and high multipoles. Using low-ℓ polarization information from LFI and WMAP, we find a best-fit value of τ = 0.066 ± 0.013, which is higher than the low value of τ = 0.052 ± 0.008 derived from Planck 2018 and slightly lower than the value of 0.069 ± 0.011 derived from the joint analysis of official LFI and WMAP products. Most importantly, however, we find that the uncertainty derived in the BEYONDPLANCK processing is about 30 % greater than when analyzing the official products, after taking into account the different sky coverage. We argue that this uncertainty is due to a marginalization over a more complete model of instrumental and astrophysical parameters, which results in more reliable and more rigorously defined uncertainties. We find that about 2000 Monte Carlo samples are required to achieve a robust convergence for a low-resolution cosmic microwave background (CMB) covariance matrix with 225 independent modes, and producing these samples takes about eight weeks on a modest computing cluster with 256 cores.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutron multiplication error in TRU waste measurements

Total Measurement Uncertainty (TMU) in neutron assays of transuranic waste (TRU) are comprised of several components including counting statistics, matrix and source distribution, calibration inaccuracy, background effects, and neutron multiplication error. While a minor component for low plutonium masses, neutron multiplication error is often the major contributor to the TMU for items containing more than 140 g of weapons grade plutonium. Neutron multiplication arises when neutrons from spontaneous fission and other nuclear events induce fissions in other fissile isotopes in the waste, thereby multiplying the overall coincidence neutron response in passive neutron measurements. Since passive neutron counters cannot differentiate between spontaneous and induced fission neutrons, multiplication can lead to positive bias in the measurements. Although neutron multiplication can only result in a positive bias, it has, for the purpose of mathematical simplicity, generally been treated as an error that can lead to either a positive or negative result in the TMU. While the factors that contribute to neutron multiplication include the total mass of fissile nuclides, the presence of moderating material in the matrix, the concentration and geometry of the fissile sources, and other factors; measurement uncertainty is generally determined as a function of the fissile mass in most TMU software calculations because this is the only quantity determined by the passive neutron measurement. Neutron multiplication error has a particularly pernicious consequence for TRU waste analysis because the measured Fissile Gram Equivalent (FGE) plus twice the TMU error must be less than 200 for TRU waste packaged in 55-gal drums and less than 325 for boxed waste. For this reason, large errors due to neutron multiplication can lead to increased rejections of TRU waste containers. This report will attempt to better define the error term due to neutron multiplication and arrive at values that are more realistic and accurate. To do so, measurements of standards and waste drums were performed with High Efficiency Neutron Counters (HENC) located at Los Alamos National Laboratory (LANL). The data were analyzed for multiplication effects and new estimates of the multiplication error were computed. A concluding section will present alternatives for reducing the number of rejections of TRU waste containers due to neutron multiplication error.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bayesian inference for the seismic moment tensor using regional waveforms and a data-derived distribution of velocity models

The largest source of uncertainty in any source inversion is the velocity model used to construct the transfer function employed in the forward model that relates observed ground motion to the seismic moment tensor. However, standard inverse procedures often does not quantify uncertainty in the seismic moment tensor due to error in the Green’s functions from uncertain event location and Earth structure. We attempt to incorporate this uncertainty into an estimation of the seismic moment tensor using a distribution of velocity models calculated in a prior effort based on different and complementary data sets. The posterior distribution of velocity models is then used to construct Green’s functions for use in Bayesian inference of an unknown seismic moment tensor using regional waveform data. The combined likelihood is estimated using data-specific error models and the posterior of the seismic moment tensor is estimated and can be interpreted in terms of most-probable source-type.

58 GEOSCIENCES↗

A comparison of SPH artificial viscosities and their impact on the Keplerian disk

Hydrodynamical simulations of rotating disks play important roles in the field of astrophysical and planetary science. Smoothed particle hydrodynamics (SPH) has been widely used for such simulations. However, it has been known that when using SPH, a cold and thin Kepler disk breaks up due to the unwanted angular momentum transfer. Two possible reasons have been suggested for this breaking up of the disk; the artificial viscosity (AV) and the numerical error in the evaluation of pressure gradient in SPH. Which one is dominant is still unclear. In this paper, we investigate the reason for this rapid breaking up of the disk. We implemented most of the popular formulations of AV and switches, and measured the angular momentum transfer due to both AV and the error of SPH’s estimate of the pressure gradient. We found that the angular momentum transfer due to AV at the inner edge triggers the breaking up of the disk. We also found that the classical von Neumann–Richtmyer–Landshoff type AV with a high-order estimate for ∇⋅v can maintain the disk for ∼100 orbits even when used with the standard formulation of SPH.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrated Nondestructive Assay Systems to Estimate Plutonium in Spent Fuel Assemblies

An integrated nondestructive assay (NDA) system combining active (neutron generator) and passive neutron detection and passive gamma (PG) detection is being analyzed in order to estimate the amount of plutonium, verify initial enrichment, burnup, and cooling time, and detect partial defects in a spent fuel assembly (SFA). Active signals are measured using the differential die-away (DDA), delayed neutron (DN), and delayed gamma (DG) techniques. Passive signals are measured using total neutron (TN) counts and both gross and spectral resolved gamma counts. To quantify how a system of several NDA techniques is expected to perform, all of the relevant NDA techniques listed above were simulated as a function of various reactor conditions such as initial enrichment, burnup, cooling time, assembly shuffling pattern, reactor operating conditions (including temperature, pressure, and the presence of burnable poisons) by simulating the NDA response for five sets of light water reactor assemblies. In this study, we compare the performance of several exploratory model-fitting options (including neural networks, adaptive regression with splines, iterative bias reduction smoothing, projection pursuit regression, and regression with quadratic terms and interaction terms) to relate data simulated with measurement and model error effects from various subsets of the NDA techniques to the total Pu mass. Isotope masses for SFAs and expected detector responses (DRs) for several NDA techniques are simulated using MCNP, and the DRs become inputs to the fitting process. Such responses include eight signals from DDA, one from DN, one from TN, and up to seven from PG; the DG signal will be examined separately. Results are summarized using the root-mean-squared estimation error for plutonium mass in held-out subsets of the data for a range of model and measurement error variances. Different simulation assumptions lead to different spent fuel libraries relating DRs to Pu mass. Some results for training with one library and testing with another library are also given.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Unscented Kalman Filter-based Unbiased Minimum-Variance Estimation for Nonlinear Systems with Unknown Inputs

This paper proposes an unscented Kalman filter (UKF)-based unbiased minimum-variance estimation (UMV) method for the nonlinear system with unknown inputs. By utilizing the statistical linerization, the nonlinear system and measurement functions are transformed into a “linear-like” regression form. The latter preserves the nonlinearity of the system and the measurement models. To this end, the unknown inputs can be estimated by the weighted least-squares. This “linear-like” regression form also allows us to resort to the UMV state estimation framework for the development of new nonlinear filter to handle unknown inputs. Specifically, two approaches have been developed: 1) given the estimated inputs, we derive a filter by minimizing the trace of the state error covariance matrix; 2) without input estimation, we derive the filter by minimizing the trace of the state error covariance matrix subject to a constraint imposed on the gain matrix. We prove that these two approaches provide the same results. Numerical results validate the effectiveness of the proposed method.

Unscented Kalman filter, unbiased minimumvariance ↗