Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Optimization of the Swift X-Ray Follow-Up of Advanced LIGO and Virgo Gravitational Wave Triggers in 2015-16

One of the most exciting near-term prospects in physics is the potential discovery of gravitational waves by the Advanced LIGO and Virgo detectors. To maximize both the confidence of the detection and the science return, it is essential to identify an electromagnetic counterpart.This is not trivial, as the events are expected to be poorly localized, particularly in the near-term, with error regions covering hundreds or even thousands of square degrees. In this paper, we discuss the prospects for finding an X-ray counterpart to a gravitational wave trigger with the Swift X-ray Telescope, using the assumption that the trigger is caused by a binary neutron star merger which also produces a short gamma-ray burst. We show that it is beneficial to target galaxies within the GW error region, highlighting the need for substantially complete galaxy catalogues out to distances of 300 Mpc. We also show that nearby, on-axis short GRBs are either extremely rare, or are systematically less luminous than those detected to date. We consider the prospects for detecting afterglow emission from an off-axis GRB which triggered the GW facilities, finding that the detectability, and the best time to look,are strongly dependent on the characteristics of the burst such as circumburst density and our viewing angle.

gravitational waves – methods: observational –↗

The Bright Gamma-Ray Transient GRO J1838-0145: Multiwavelength Studies of X-Ray Novae

We completed the observational work regarding the bright gamma-ray transient GRO J1838-014 that might be a representative of a new class of gamma-ray sources in our Galaxy. A bright gamma-ray flare was detected by EGRET in June 1996. Its time variability (approx. weeks) and the absence of a clearly identified radio-loud (-approx. 1 Jy) blazar in its error box are crucial for our interpretation of GRO J1838-014 as an object different from gamma-ray blazars or isolated pulsars. We also observed the error box with ASCA and SAX pointings without identifying obvious candidate counterparts. The X-ray flux in quiescence, if any, is quite low, and canonical X-ray binary systems are also excluded. GRO J1838-014 is not the only non-blazar gamma-ray transients detected by EGRET in the Galactic plane. An analysis of CGRO Cycle 4 data is being completed in collaboration with R. Mukherjee and J. Mattox with the discussion of other interesting unidentified sources. Pulsars embedded in transient gaseous surroundings (maybe in binary systems) or compact objects in special systems are plausible candidates. A theoretical analysis is being developed. We also continued the study of Galactic X-ray novae, in particular of systems producing radio jets such as GRS 1915+10. The use of Green Bank Interferometer data (of which the MT is the chair of the executive committee) has been of great use to GRO and other satellite missions. We completed a study of X-ray/radio outbursts of GRS 1915+10 with BSAX and Ryle radiotelescope data and CGRO/BATSE simultaneous data. We also continued our theoretical work on gamma-ray bursts.

Tavani, Marco↗

Discovery of the 198 Second X-Ray Pulsar GRO J2058+42

GRO J2058+42, a transient 198 s X-ray pulsar, was discovered by the Burst and Transient Source Experiment (BATSE) on the Compton Gamma Ray Observatory (CGRO) during a "giant" outburst in 1995 September-October. The total flux peaked at about 300 mcrab (20-50 keV) as measured by Earth occultation. The pulse period decreased from 198 to 196 s during the 46 day outburst. The pulse shape evolved over the course of the outburst and exhibited energy-dependent variations. BATSE observed five additional weak outbursts from GRO J2058 + 42, each with a 2 week duration and a peak-pulsed flux of about 15 mcrab (20-50 keV), that were spaced by about 110 days. An observation of the 1996 November outburst by the Rossi X-Ray Timing Explorer (RXTE) proportional counter array (PCA) localized the source to within a 4 s radius error circle (90% confidence) centered on R.A. = 20h 59m.0, decl. = 41 deg 43 s (J2000). Additional shorter outbursts with peak-pulsed fluxes of about 8 mcrab were detected by BATSE halfway between the first four 15 mcrab outbursts. The RXTE All-Sky Monitor detected all eight weak outbursts with approximately equal durations and intensities. GRO J2058 + 42 is most likely a Be/X-ray binary that appears to outburst at periastron and apastron, No optical counterpart has been identified to date, and no X-ray source was present in the error circle in archival ROSAT observations.

Wilson, Colleen A.↗

A fault-tolerant neutral-atom architecture for universal quantum computation

Quantum error correction (QEC) is essential for the realization of large-scale quantum computers. However, owing to the complexity of operating on the encoded ‘logical’ qubits, understanding the physical principles for building fault-tolerant quantum devices and combining them into efficient architectures is an outstanding scientific challenge. Here we use reconfigurable arrays of up to 448 neutral atoms to implement the key elements of a universal, fault-tolerant quantum processing architecture and experimentally explore their underlying working mechanisms. We first use surface codes to study how repeated QEC suppresses errors, demonstrating 2.14(13)x below-threshold performance in a four-round characterization circuit by leveraging atom loss detection and machine learning decoding. We then investigate logical entanglement using transversal gates and lattice surgery and extend it to universal logic through transversal teleportation with three-dimensional [[15,1,3]] codes, enabling arbitrary-angle synthesis with polylogarithmic overhead. Finally, we develop mid-circuit qubit reuse16, increasing experimental cycle rates by two orders of magnitude and enabling deep-circuit protocols with dozens of logical qubits and hundreds of logical teleportations with [[7,1,3]] and high-rate [[16,6,4]] codes while maintaining constant internal entropy. Our experiments show key principles for efficient architecture design, involving the interplay between quantum logic and entropy removal, judiciously using physical entanglement in logic gates and magic state generation, and leveraging teleportations for universality and physical qubit reset. These results establish foundations for scalable, universal error-corrected processing and its practical implementation in neutral atom systems.

atomic and molecular physics↗

Arc-Second Pointer for Balloon-Borne Astronomical Instrument

A control system has been designed to keep a balloon-borne scientific instrument pointed toward a celestial object within an angular error of the order of an arc second. The design is intended to be adaptable to a large range of instrument payloads. The initial payload to which the design nominally applies is considered to be a telescope, modeled as a simple thin-walled cylinder 24 ft (approx.= 7.3 m) long, 3 ft (approx.= 0.91 m) in diameter, weighing 1,500 lb (having a mass of .680 kg). The instrument would be mounted on a set of motor-driven gimbals in pitch-yaw configuration. The motors on the gimbals would apply the control torques needed for fine adjustments of the instrument in pitch and yaw. The pitch-yaw mount would, in turn, be suspended from a motor mount at the lower end of a pair of cables hanging down from the balloon (see figure). The motor in this mount would be used to effect coarse azimuth control of the pitch-yaw mount. A notable innovation incorporated in the design is a provision for keeping the gimbal bearings in constant motion. This innovation would eliminate the deleterious effects of static friction . something that must be done in order to achieve the desired arc-second precision. Another notable innovation is the use of linear accelerometers to provide feedback that would facilitate the early detection and counteraction of disturbance torques before they could integrate into significant angular-velocity and angular-position errors. The control software processing the sensor data would be capable of distinguishing between translational and rotational accelerations. The output of the accelerometers is combined with that of angular position and angular-velocity sensors into a proportional + integral + derivative + acceleration control law for the pitch and yaw torque motors. Preliminary calculations have shown that with appropriate gains, the power demand of the control system would be low enough to be satisfiable by means of storage batteries charged by solar batteries during the day.

Ward, Philip R.↗

The Third EGRET Catalog of High-Energy Gamma-Ray Sources

The third catalog of high-energy gamma-ray sources detected by the EGRET telescope on the Compton Gamma Ray Observatory includes data from 1991 April 22 to 1995 October 3 (Cycles 1, 2, 3, and 4 of the mission). In addition to including more data than the second EGRET catalog (Thompson et al. 1995) and its supplement (Thompson et al. 1996), this catalog uses completely reprocessed data (to correct a number of mostly minimal errors and problems). The 271 sources (E greater than 100 MeV) in the catalog include the single 1991 solar flare bright enough to be detected as a source, the Large Magellanic Cloud, five pulsars, one probable radio galaxy detection (Cen A), and 66 high-confidence identifications of blazars (BL Lac objects, flat-spectrum radio quasars, or unidentified flat-spectrum radio sources). In addition, 27 lower-confidence potential blazar identifications are noted. Finally, the catalog contains 170 sources not yet identified firmly with known objects, although potential identifications have been suggested for a number of those. A figure is presented that gives approximate upper limits for gamma-ray sources at any point in the sky, as well as information about sources listed in the second catalog and its supplement which do not appear in this catalog.

Hartman, R. C.↗

Photovoltaic System Health-State Architecture for Data-Driven Failure Detection

The timely detection of photovoltaic (PV) system failures is important for maintaining optimal performance and lifetime reliability. A main challenge remains the lack of a unified health-state architecture for the uninterrupted monitoring and predictive performance of PV systems. To this end, existing failure detection models are strongly dependent on the availability and quality of site-specific historic data. The scope of this work is to address these fundamental challenges by presenting a health-state architecture for advanced PV system monitoring. The proposed architecture comprises of a machine learning model for PV performance modeling and accurate failure diagnosis. The predictive model is optimally trained on low amounts of on-site data using minimal features and coupled to functional routines for data quality verification, whereas the classifier is trained under an enhanced supervised learning regime. The results demonstrated high accuracies for the implemented predictive model, exhibiting normalized root mean square errors lower than 3.40% even when trained with low data shares. The classification results provided evidence that fault conditions can be detected with a sensitivity of 83.91% for synthetic power-loss events (power reduction of 5%) and of 97.99% for field-emulated failures in the test-bench PV system. Finally, this work provides insights on how to construct an accurate PV system with predictive and classification models for the timely detection of faults and uninterrupted monitoring of PV systems, regardless of historic data availability and quality. Such guidelines and insights on the development of accurate health-state architectures for PV plants can have positive implications in operation and maintenance and monitoring strategies, thus improving the system’s performance.

photovoltaics↗

Discovery of the 198 s X-Ray Pulsar GRO J2058+42

GRO J2058+42, a transient 198 second x-ray pulsar, was discovered by the Burst and Transient Source Experiment (BATSE) on the Compton Gamma-Ray Observatory (CGRO), during a "giant" outburst in 1995 September-October. The total flux peaked at about 300 mCrab (20-50 keV) as measured by Earth occultation. The pulse period decreased from 198 s to 196 s during the 46-day outburst. The pulse shape evolved over the course of the outburst and exhibited energy dependent variations. BATSE observed five additional weak outbursts from GRO J2058+427 each with two week duration and peak pulsed flux of about 15 mcrab (20-50 keV), that were spaced by about 110 days. An observation of the 1996 November outburst by the Rossi X-ray Timing Explorer (RXTE) Proportional Counter Array (PCA) localized the source to within a 4' radius error circle (90% confidence) centered on R.A. = 20 h 59 m.0, Decl. = 41 deg 43 min (J2000). Additional shorter outbursts with peak pulsed fluxes of about 8 mCrab were detected by BATSE halfway between the first four 15 mCrab outbursts. The RXTE All-Sky Monitor detected 8 weak outbursts with approximately equal durations and intensities. GRO J2058+42 is most likely a Be/X-ray binary that appears to outburst at periastron and apastron. No optical counterpart has been identified to date and no x-ray source was present in the error circle in archival ROSAT observations.

Wilson, Colleen A.↗

Enhancing strontium clock atom interferometry using quantum optimal control

Strontium clock atom interferometry is a promising new technology, with multiple experiments under development around the world to explore its potential for dark matter and gravitational wave detection. In these detectors, large momentum transfer using sequences of many laser pulses is necessary, and thus high-fidelity pulses are important since small errors become magnified. Quantum optimal control (QOC) is a framework for developing control pulse waveforms that achieve high fidelity and are robust against experimental imperfections. Resonant single-photon transitions using the narrow clock transition of strontium involve significantly different quantum dynamics than more established atom interferometry methods based on far-detuned two-photon Raman or Bragg transitions, which leads to new opportunities and challenges when applying QOC. Here, we study in simulation QOC pulses for strontium clock interferometry and demonstrate their advantage over basic square pulses (primitive pulses) and composite pulses in terms of robustness against multiple noise channels. In conclusion, this could improve the scale of large momentum transfer in Sr clock interferometers, paving the way to achieving these scientific goals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of slow and fast phase nystagmus

A current literature review of the analog and digital process of vestibular and optical kinetic nystagmus reveals little agreement in the methods used by various labs. The strategies for detection of saccade (fast phase velocity component of nystagmus) vary between labs, and most of the process have not been evaluated and validated with a standard database. A survey was made of major vestibular labs in the U.S. that perform computer analyses of vestibular and optokinetic reflexes to stimuli, and a baseline was established from which to standardize data acquisition and analysis programs. The concept of an Error Index was employed as the criterium for evaluating the performance of the vestibular analysis software programs. The performance criterium is based on the detection of saccades and is the average of the percentages of missed detections and false detections. Evaluation of the programs produced results for lateral gaze with saccadic amplitude of one, two, three, five, and ten degrees with various signal-to-noise ratios. In addition, results were obtained for sinusoidal pursuit of 0.05, 0.10, and 0.50 Hz with saccades from one to ten degrees at various signal-to-noise ratios. Selection of the best program was made from the performance in the lateral gaze with three degrees of saccadic amplitude and in the 0.10 Hz sinusoid with three degrees of saccadic amplitude.

Lessard, Charles S.↗

Screening IMS Seismic Detections using Dynamic Correlation Processor: Progress report for 2020

LLNL completed the FY20 workplan entailing application of the Dynamic Correlation Processor (DCP) to International Monitoring System (IMS) primary seismic data in 2019 and 2020. The effective analysis period was curtailed to January 1 through November 12, 2019 due to a data compression change that rendered later data unusable. Fixing the data compression error is a priority for our data source, and we plan to extend the period of data analysis when the fix is implemented. We found that the percentage overlap between detections generated by the International Data Centre (IDC) DFX software and detections generated by DCP varied widely by station. Overlap is 30-40% at some stations, suggesting that a large percentage of DFX detections could be screened (removed) from the detection-event association algorithm. However, detection overlap was much lower, a few percent, at many stations and the percentage overlap was low at stations known to have many mines and other local sources of seismicity. Unexpectedly low detection overlap at many stations prompted us to examine results for the ARCES station in detail. There is considerable mine activity near ARCES, but our initial FY20 analysis found only ~2% DCP/DFX detection overlap. Differences in the pre-processing (e.g. beam recipes) used by DCP and DFX appear to be the cause of low detection overlap at ARCES. DCP uses wideband filters to improve detector robustness and the IDC uses narrow-band pre-filtering to improve sensitivity. After reprocessing ARCES using the IDC beam recipe, DCP/DFX overlap increased to ~74%. This result shows that we must reprocess the IMS network using the IDC station-specific beam recipes if we are to effectively screen DFX detections and improve automatic event building performance at the IDC.

58 GEOSCIENCES↗

A Diagnostic Analysis of the Kennedy Space Center LDAR Network: Cross-Sensor Studies - 2

Range dependencies in total (intracloud and cloud-to-ground) lightning observed by the Kennedy Space Center Lightning Detection and Ranging (LDAR) network are established through cross-comparison with other lightning sensors. Using total lightning observed by the Lightning Imaging Sensor (LIS), LDAR flash detection efficiency is shown to remain above 90% out to 90-100 km range, and to be below 25% at 200 km range. LDAR VHF source location error distributions are also determined as a function of range, and are found to be asymmetric with first moments increasing roughly as range squared. Range normalization schemes for total VHF source density are tested and shown to yield significant (up to 50%) skill improvements over uncorrected data, when compared with National Lightning Detection Network (NLDN) ground flash counts at hourly, daily, monthly and climatological time scales.

Boccippio, D. J.↗

Application of OMI, SCIAMACHY and GOME-2 Satellite SO2 Retrievals for Detection of Large Emission Sources

Retrievals of sulfur dioxide (SO2) from space-based spectrometers are in a relatively early stage of development. Factors such as interference between ozone and SO2 in the retrieval algorithms often lead to errors in the retrieved values. Measurements from the Ozone Monitoring Instrument (OMI), Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY), and Global Ozone Monitoring Experiment-2 (GOME-2) satellite sensors, averaged over a period of several years, were used to identify locations with elevated SO2 values and estimate their emission levels. About 30 such locations, detectable by all three sensors and linked to volcanic and anthropogenic sources, were found after applying low and high spatial frequency filtration designed to reduce noise and bias and to enhance weak signals to SO2 data from each instrument. Quantitatively, the mean amount of SO2 in the vicinity of the sources, estimated from the three instruments, is in general agreement. However, its better spatial resolution makes it possible for OMI to detect smaller sources and with additional detail as compared to the other two instruments. Over some regions of China, SCIAMACHY and GOME-2 data show mean SO2 values that are almost 1.5 times higher than those from OMI, but the suggested spatial filtration technique largely reconciles these differences.

SO2 retrievals↗

The Disk Wind in the Rapidly Spinning Stellar-mass Black Hole 4U 1630-472 Observed with NuSTAR

We present an analysis of a short NuSTAR observation of the stellar-mass black hole and low-mass X-ray binary 4U 1630−472. Reflection from the inner accretion disk is clearly detected for the first time in this source, owing to the sensitivity of NuSTAR. With fits to the reflection spectrum, we find evidence for a rapidly spinning black hole, a∗ = 0.985(+0.005/−0.014) (1 sigma statistical errors). However, archival data show that the source has relatively low radio luminosity. Recently claimed relationships between jet power and black hole spin would predict either a lower spin or a higher peak radio luminosity. We also report the clear detection of an absorption feature at 7.03 +/- 0.03 keV, likely signaling a disk wind. If this line arises in dense, moderately ionized gas (log xi = 3.6(+0.2/−0.3) and is dominated by He-like Fe xxv, the wind has a velocity of v/c = 0.043(+0.002/−0.007) (12900(+600/−2100) km s(exp −1)). If the line is instead associated with a more highly ionized gas (log xi = 6.1(+0.7/−0.6)), and is dominated by Fe xxvi, evidence of a blueshift is only marginal, after taking systematic errors into account. Our analysis suggests the ionized wind may be launched within 200-1100 Rg, and may be magnetically driven.

accretion disks↗

Fractal Scaling of Explosively Driven Product Gases

ABSTRACT Characterization of the interface between explosive product gases and ambient air in an explosion is a complicated task due to the turbulent mixing and inherently three‐dimensional expansion of the interface. This study aims to quantify the evolution of the interface as a temporally varying Hausdorff dimension. Two test series were conducted with Composition C‐4 charges with masses of 105 and 880 g. Imaging data were collected from the time of detonation until shock wave detachment using ultra‐high‐speed cameras. Gas cloud profiles were extracted using automated image processing algorithms, and the Hausdorff dimension of these two‐dimensional slices of the gas cloud was then estimated using boxcounting algorithms. When scaled with standard gas dynamic nondimensional scalings, the Hausdorff dimension of all explosive events appears to collapse towards a single curve. The fireball was initially nonfractal and began to develop fractal properties as the shock wave separated from the detonation products. Artificial perturbation of the charged surface had no detectable impact on the evolution of the Hausdorff dimension in the early development of the fireball outside of error, despite visible phenomenological differences in the early development of mixing on the fireball surface.

42 ENGINEERING↗

Vacuum-ultraviolet absorption cross-sections of functionalized four-carbon species

Absorption cross-sections were measured in the vacuum ultraviolet from 5.17 – 9.92 eV using differential absorption spectroscopy for 33 four-carbon species: n-butane, trans-2-butene, cis-2-butene, butanal, butyric acid, ethyloxirane, trans-2,3-dimethyloxirane, cis-2,3-dimethyloxirane, 2-methyloxetane, 2,2'-bioxirane, vinyl oxirane, 3,4-epoxybutan-2-one, diacetyl, diethyl ether, ethyl vinyl ether, vinyl acetate, acetic anhydride, 1-butanol, 3-buten-1-ol, 1–hydroxy-butan-2-one, 1–hydroxy-butan-3-one, 2,3-epoxybutan-1-ol, 3,4-epoxybutan-1-ol, 2-oxetanemethanol, butanone, methyl vinyl ketone, 4H-1,3-dioxine, allyl formate, 2-oxobutanal, 4-hydroxybutanal, 2-methyloxetan-3-one, cis–but-2-en-1-ol, and trans-2–but-enal. Uncertainties were quantified in all cases by accounting for errors in gas-phase concentration, experimental repeatability, and signal-to-noise ratio as a function of photon energy. With the exception of 2-oxobutanal, which is reported with an uncertainty of 10%, convolving the sources of error using the root-sum-square method led to an upper limit of 5% uncertainty above the detection limit, which is largely attributable to chemical purity. Here, the primary objective of the present work is to provide absolute cross-sections along with quantified uncertainty limits. The majority of the absorption spectra, which reflect electronic transitions such as σ → σ* and n → σ*, are reported for the first time and provide insight into fundamental chemical physics, such as vibrational band structure and Rydberg transitions. The quantitative spectra in the present work facilitates the discovery of chemical intermediates that support improvement in the accuracy of computational models for low-temperature combustion and atmospheric chemistry.

biofuels↗

Expectation-propagation for weak radionuclide identification at radiation portal monitors

We propose a sparsity-promoting Bayesian algorithm capable of identifying radionuclide signatures from weak sources in the presence of a high radiation background. The proposed method is relevant to radiation identification for security applications. In such scenarios, the background typically consists of terrestrial, cosmic, and cosmogenic radiation that may cause false positive responses. We evaluate the new Bayesian approach using gamma-ray data and are able to identify weapons-grade plutonium, masked by naturally-occurring radioactive material (NORM), in a measurement time of a few seconds. We demonstrate this identification capability using organic scintillators (stilbene crystals and EJ-309 liquid scintillators), which do not provide direct, high-resolution, source spectroscopic information. Compared to the EJ-309 detector, the stilbene-based detector exhibits a lower identification error, on average, owing to its better energy resolution. Organic scintillators are used within radiation portal monitors to detect gamma rays emitted from conveyances crossing ports of entry. The described method is therefore applicable to radiation portal monitors deployed in the field and could improve their threat discrimination capability by minimizing “nuisance” alarms produced either by NORM-bearing materials found in shipped cargoes, such as ceramics and fertilizers, or radionuclides in recently treated nuclear medicine patients.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Verification of redundancy management design

Statistical method checks designs by simulating system operating conditions and adding error factors. Method has potential applicability to commercial and industrial situations where redundancy management system is used to detect and isolate failed components.

Gelderloos, H. C.↗