Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “emulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

A Reduced-Order Aggregated Model for Parallel Inverter Systems with Virtual Oscillator Control

This paper introduces a reduced-order aggregated model for parallel-connected inverters controlled with virtual oscillator control (VOC). The premise of VOC is to modulate inverter dynamics to emulate those of nonlinear oscillators with the goal of realizing a stable ac microgrid in the absence of communication, synchronous generation, or a stiff grid. To obtain a reduced-order model for a system of parallel-connected inverters with VOC, we first formulate a set of scaling laws that describe how the controller and filter parameters of a given inverter depend on its voltage and power rating. Subsequently, we show that N parallel inverters which adhere to this scaling law can be modeled with the same structure and hence the same computational burden of the model of a single inverter. The proposed aggregate model is experimentally validated on a system of three parallel inverters with heterogeneous power ratings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Self-Security for Grid-Interactive Smart Inverters Using Steady-State Reference Model

Smart inverters exchange information with other devices through a shared communication link, making the inverters more prone to receive harmful commands from external parties. This erroneous data can be received due to an anomaly in the system, such as a device fault, unintentional utility operator action, or a cyber-attack. In this paper, a device-level self-security strategy is implemented using reference models for a grid-interactive inverter to examine the incoming power setpoints, detect the anomalies, and protect the system accordingly. The PQ setpoints received from the utility supervisory controller are autonomously examined using the inverter’s normal and stable operating regions before engaging the setpoints to the inverter’s local controller. Grid parameters are estimated in real-time during the examination process. The efficacy of the self-security algorithm is tested using a three-phase 3-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative grid emulator. The results verify that the proposed method can detect harmful PQ setpoints that can cause abnormal or unstable inverter operation.

Gursoy, Mehmetcan↗

Smart Inverter Twin Model for Anomaly Detection

Smart inverters connected to a communication network are vulnerable to various anomalies in the form of cyberattacks. In this paper, a self-security approach is implemented using the digital twin concept for smart inverters. The digital twin is formed using the inverter’s dynamic model. Then, the incoming setpoints are autonomously examined using the digital twin, and only the safe setpoints are engaged to the inverter’s local controller. This paper demonstrates the details of the self-security algorithm and how the inverter’s digital twin is formed. In particular, the stable and unstable operation region is experimentally verified by changing the power setpoints engaged to the local controller, using a laboratory setup including a three-phase 1.5-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative power grid emulator. The results demonstrate that the digital twin model can potentially protect inverters from abnormal operation by examining the incoming commands (new setpoints) using the inverter’s digital twin before engaging the setpoints to the local controller.

Hossen, Tareq↗

Design and Analysis of an Integral MPPT Control Law for Wave Energy Conversion Systems

In this paper, we propose an integral-based maximum power point tracking (MPPT) algorithm for point absorber wave energy conversion (WEC) systems. A permanent magnet synchronous generator (PMSG) is coupled to the point absorber and its drive implements the proposed MPPT control. While the rotating frame of reference of the PMSG implements power control, the slower mechanical frequency of the incident waves are processed with an additional transformation that yields another set of dc dynamics. The computed dc power in the new reference frame, which is focused on slow wave dynamics, is input to the MPPT control law that tunes the emulated resistance of the machine drive to extract peak power from the wave absorber device. We derive a stability condition for the proposed controller and validate our control design on a simulated 10kW system.

wave energy, maximum power point tracking (MPPT), ↗

Biomimetic, Soft-Material Synapse for Neuromorphic Computing: from Device to Network

Neuromorphic computing refers to a variety of brain-inspired computers, devices, and models inspired by the interconnectivity, performance, and energy efficiency of the human brain. Unlike the ubiquitous von Neumann computer architectures with complex processor cores and sequential computation, biological neurons and synapses operate by storing and processing information simultaneously with the capacity of flexible adaptation resulting in massive computational capability with much less power consumption. The search for a synaptic material which can closely imitate bio-synapse has led to an alamethicin-doped, synthetic biomembrane which can emulate key synaptic functions due to generic memristive property enabling learning and computation. This two-terminal, biomolecular memristor, in contrast to its solid-state counterparts, features similar structure, switching mechanism, and ionic transport modality as biological synapses while consuming considerably lower power. In this paper, we outline a methodology for using this biomolecular synapse to build neural networks capable of solving real-world problems. The physical mechanism underlying its volatile memristance is explored followed by the development of a model of this device for circuit simulation. We outline a circuit design technique to integrate this synapse with solid-state neuron circuit for hardware implementation. Based on these results, we develop a high level simulation framework and use a training scheme called Evolutionary Optimization for Neuromorphic System (EONS) to generate networks for solving two problems, namely iris dataset classification and EEG classification task. The small network size and comparable to state-of-the-art accuracy of these preliminary networks show its potential to enhance synaptic functionality in next generation neuromorphic hardware.

Sakib hasan, Md↗

Digital Twin of an ANPC inverter with integrated Design-For-Trust

Reducing costs and increasing manufacturing output while creating reliable products are three essential components needed to keep a business competitive. In the past, having an asset that could address these three challenges at the same time would be challenging. However, recent advances in computer processing capabilities coupled with increases to network speeds allowed such a system to become possible; and this is known as a Digital Twin (DT), which represents a virtual copy of a production system or a product. Here, this work exhibits a DT application of an Active Neutral Point Clamped (ANPC) inverter using a controller. The controller emulates the ANPC responses of a new Digital Signal Processing (DSP) firmware and validates this new firmware by using Design-For-Trust (DFTr) characteristics. If the new firmware is malicious, then it should be rejected, thus adding preemptive protection measures for inverter based distributed energy resources.

cybersecurity↗

Advanced Grid Simulator for Multi-Megawatt Power Converter Testing and Certification

Grid integration testing of inverter-coupled renewable energy technologies is an essential step in the qualification of renewable energy and energy storage systems to ensure the stability of the power system. New types of devices must be thoroughly tested and validated for compliance with relevant grid codes and interconnection requirements. For this purpose, highly specialized custom-made testing equipment is needed to emulate various types of realistic grid conditions that are required by certification bodies or for research purposes. For testing multi-megawatt converters, a high power grid simulator capable of creating controlled grid conditions and meeting both power quality and dynamic characteristics is needed. This paper describes the new grid simulator concept based on ABB's medium voltage ACS6000 drive technology that utilizes advanced modulation and control techniques to create an unique testing platform for various multi-megawatt power converter systems. Its performance is demonstrated utilizing the test results obtained during commissioning activities at the National Renewable Energy Laboratory in Colorado, USA.

17 WIND ENERGY↗

Enhancing Power System Transient Stability by Virtual Synchronous Generator Control Using Wide-Area Measurements

Virtual synchronous generator control provides a potential solution to connect power electronics interfaced sources to the power system. With its flexible control, the emulated inertia may be adaptively changed to enhance system small-signal stability. However, previously proposed methods may have adverse impact to system transient stability. This paper proposes to improve the methods by using wide-area measurements, namely center of inertia frequency. Experimental results are presented to both demonstrate the limitations of previous control schemes, and the effectiveness of the proposed one. The practical implementation of this method is discussed.

Ma, Yiwei↗

Digital Twin for Self-Security of Smart Inverters

Smart inverters connected to a communication network are susceptible to man-in-the-middle attacks. In this paper, a self-security approach is implemented using the digital twin concept for smart inverters. The digital twin is formed using the inverter’s normal operating region and the inverter’s dynamic model. Then, the incoming setpoints are autonomously examined using the digital twin, and only the safe setpoints are engaged to the inverter’s local controller. This paper demonstrates how the inverter’s normal operating region and dynamic model are formed. In particular, the normal operation region is experimentally verified by changing the P and Q setpoints engaged to the local controller, using a laboratory setup including a three-phase 3-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative power grid emulator. The results demonstrate that the self-security technique can potentially protect inverters from man-in-the-middle attacks by examining the incoming commands (new setpoints) using the inverter’s digital twin before engaging the setpoints to the local controller.

Hossen, Tareq↗

Development of a Power Electronics-based Testbed for a Flexible Combined Heat and Power System

A flexible combined heat and power (F-CHP) concept, enabled by a power electronics-based power conditioning system (PCS), has been recently proposed as a cost-effective way for supporting the grid with high penetration of renewable energy sources. To verify the design, control, and performance of the overall system, a laboratory-scale testbed is essential. This paper focuses on the development of a power electronics-based testbed for such a F-CHP system. The developed testbed can test the control, grid-connected mode operation, islanded mode operation, and mode transitions, including planned/unplanned islanding and reconnection, of the F-CHP system. In the grid-connected mode, both the steady state and transients of the ac grid can be emulated, and various grid support functions can be tested with the help of the developed PCS converter. In the islanded mode, the external ac loads can also be supported by the F-CHP system. Also, the central controller, which is implemented in a NI CompactRIO, can be tested. Experimental test results for the grid-connected mode, islanded mode, and mode transitions are provided to validate the testbed design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Internal Model Based Current Control with Embedded Active Damping of a Three-Phase Grid-Connected Inverter with LCL Filter for PV Application

This paper presents an internal model based controller with embedded active damping for a three-phase grid-connected inverter with LCL filter. A strategy to control the grid current based on the internal model principle is presented in this paper. It is known that a third-order LCL filter apart from providing better attenuation also poses the problem of initiating unwanted resonance oscillations especially during transients. To address this problem, an active damping strategy based on virtual resistance emulation on the grid side filter is implemented. Also, to ensure effective active damping, an online parameter update strategy is implemented for the filter parameters. The proposed method provides better attenuation to oscillation damping and achieves good tracking performance without adversely affecting the bandwidth. The architecture is verified based on computer simulations via MATLAB/Simulink and PLECS domain and various important case study results are presented.

grid-connected inverter↗

On Stability of PQ-Controlled Grid-Following and Droop-Control Grid-Forming Inverters

In this paper, the nonlinearity impacts of PQ-control schemes and LCL filter parameter variations on the stability of grid-interactive inverters are studied under weak grid conditions. This work demonstrates that the control nonlinearity and parameter variations can cause unexpected instability at low power levels. This instability issue in the nominal operating range may occur under specific control parameters due to the shift of the low-frequency eigenvalues of PQ-controlled inverters. A full-order small-signal model for PQ-controlled inverters is applied to analyze this instability issue. Furthermore, the impacts of the droop coefficients on the stability of the droop-controlled grid-forming inverter are also investigated using the closed-loop inverter model. The findings are experimentally verified using a small-scale two-level 208 V, 5 kVA inverter feeding a 12 kW NHR 9410 power grid emulator and a hardware setup of a microgrid fed by two 5 kVA 208V inverters.

Hossen, Tareq↗

A Networked Microgrid Framework and Testbed for Communication, Controls, and Optimization Testing

This paper presents the development and experimental results of a networked AC microgrid testbed located at Oak Ridge National Laboratory. The testbed comprises two, 480V three-phase, four wire microgrids designed to operate standalone, grid-tied, or as a network of microgrids. This testbed represents both the state of the industry, by incorporating grid-assets commonly found in real microgrids, and the state of the art, as it is a platform to evaluate advanced controllers. The main elements of this networked microgrid testbed are presented in this paper including a Scenario Manager, local microgrid controls, and a networked microgrid control. The Scenario Manager has the objective of emulating real-world conditions. The local microgrid controller oversees standalone, grid-tied, or islanded operation. The microgrid control is a higher-level control that coordinates interaction between islanded microgrids. This paper delves into these controllers and validates their operation in the networked microgrid testbed showcasing the operational flexibility and advance control capabilities.

Ferrari Maglia, Max↗

Self-Secure Inverters Against Malicious Setpoints

The next generation of grid-interactive inverters brings a communication feature that allows data sharing from utility supervisory controllers and smart devices that are connected to the same network. This feature enhances the control capabilities of grid-interactive inverters to provide services beyond active power injection. However, communication networks entail more vulnerable surfaces to malicious attacks that may result in modifying active and reactive power setpoints and causing weak-grid conditions or abnormal inverter operation. In this paper, steady-state and the dynamic behavior of the inverter for the incoming setpoints are analyzed to detect false data injection attacks and provide device-level security. The steady-state behavior of the inverter in the operating region is determined from the grid parameters such as the grid voltage and the grid impedance. These estimations are accomplished by the proposed self-security technique through a low-frequency signal injection-based approach combined with the recursive least square method. Moreover, a reduced fourth-order inverter model is used as the dynamic reference model, and grid parameters as well as the incoming setpoints are implemented to the reference model to verify whether the dynamic behavior of the inverter is inside the permissible region of operation. The validity and performance of the proposed method are verified experimentally through Allen-Bradley Powerflex 755 three-phase inverter and a 12 kW NHR 9410 regenerative power grid emulator. The results show that the self-secure smart-inverter is able to accept or reject the incoming commands and thus is protected from malicious cyber-physical attacks.

Hossen, Tareq↗

High-Penetration Microgrids Providing Grid Stability Using Frequency Watt Control

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint. Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.

14 SOLAR ENERGY↗

Experimental Analysis of File Transfer Rates over Wide-Area Dedicated Connections

File transfers over dedicated connections, supported by large parallel file systems, have become increasingly important in high-performance computing and big data workflows. It remains a challenge to achieve peak rates for such transfers due to the complexities of file I/O, host, and network transport subsystems, and equally importantly, their interactions. We present extensive measurements of disk-to-disk file transfers using Lustre and XFS file systems mounted on multi-core servers over a suite of 10 Gbps emulated connections with 0-366 ms round trip times. Our results indicate that large buffer sizes and many parallel flows do not always guarantee high transfer rates. Furthermore, large variations in the measured rates necessitate repeated measurements to ensure confidence in inferences based on them. We propose a new method to efficiently identify the optimal joint file I/O and network transport parameters using a small number of measurements. We show that for XFS and Lustre with direct I/O, this method identifies configurations achieving 97% of the peak transfer rate while probing only 12% of the parameter space.

Rao, Nageswara S.↗

Experiments and Analyses of Data Transfers Over Wide-Area Dedicated Connections

Dedicated wide-area network connections are increasingly employed in high-performance computing and big data scenarios. One might expect the performance and dynamics of data transfers over such connections to be easy to analyze due to the lack of competing traffic. However, non-linear transport dynamics and end-system complexities (e.g., multi-core hosts and distributed filesystems) can in fact make analysis surprisingly challenging. We present extensive measurements of memory-to-memory and disk-to-disk file transfers over 10 Gbps physical and emulated connections with 0–366 ms round trip times (RTTs). For memory-to-memory transfers, profiles of both TCP and UDT throughput as a function of RTT show concave and convex regions; large buffer sizes and more parallel flows lead to wider concave regions, which are highly desirable. TCP and UDT both also display complex throughput dynamics, as indicated by their Poincare maps and Lyapunov exponents. For disk-to-disk transfers, we determine that high throughput can be achieved via a combination of parallel I/O threads, parallel network threads, and direct I/O mode. Our measurements also show that Lustre filesystems can be mounted over long-haul connections using LNet routers, although challenges remain in jointly optimizing file I/O and transport method parameters to achieve peak throughput.

Rao, Nageswara S.↗

On Projection of Safe Operation for Grid-Following Inverters - Grid Parameter Estimation

This work investigates the projection of safe operation for grid-following inverters using a reference model. This work applies recursive-least square and model reference adaptive estimation techniques to estimate the unknown grid parameters. The estimated grid parameters are used in a dynamic reference model to project the safe operation of the inverter. This work also demonstrates that the controller nonlinearity and parameter variations can cause unsafe operations, such as unexpected instability at low power levels, namely hidden mode of instability. This instability issue in the nominal operating range may occur for given control parameters in a weak-grid condition. The dynamic reference model for PQ-controlled inverters is applied to analyze this instability issue using the estimated grid parameters. Both adaptive identification techniques can estimate the unknown parameters accurately, and the dynamic reference model can safeguard inverters from an unsafe operation, i.e., hidden instability, by examining the incoming new power setpoints before engaging them to the local controller. The findings are experimentally verified using a small-scale two-level 208 V, 5 kVA inverter feeding a 12 kW NHR 9410 power grid emulator.

Hossen, Tareq↗