Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical fluids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Performance Testing of a Prototypic Annular Linear Induction Pump for Fission Surface Power

Results of performance testing of an annular linear induction pump are presented. The pump electromagnetically pumps liquid metal (NaK) through a circuit specially designed to allow for quantification of the performance. Testing was conducted over a range of conditions, including frequencies of 33, 36, 39, and 60 Hz, liquid metal temperatures from 25 to 525 C, and input voltages from 5 to 120 V. Pump performance spanned a range of flow rates from roughly 0.16 to 5.7 L/s (2.5 to 90 gpm), and pressure head <1 to 90 kPa (<0.145 to 13 psi). The maximum efficiency measured during testing was slightly greater than 6%. The efficiency was fairly insensitive to input frequency from 33 to 39 Hz, and was markedly lower at 60 Hz. In addition, the efficiency decreased as the NaK temperature was raised. While the pump was powered, the fluid responded immediately to changes in the input power level, but when power was removed altogether, there was a brief slow-down period before the fluid would come to rest. The performance of the pump operating on a variable frequency drive providing 60 Hz power compared favorably with the same pump operating on 60 Hz power drawn directly from the electrical grid.

Polzin, K. A.↗

Cobalt-substituted perovskite compounds for solid oxide electrochemical cells

Oxygen electrodes are provided, comprising a perovskite compound having Formula (I), Sr(Ti 1-x Fe x-y Co y )O 3-δ wherein 0.90 ≥ x ≥ 0.40 and 0.02 ≥ y ≥ 0.30. Electrochemical devices comprising such oxygen electrodes are also provided, comprising a counter electrode in electrical communication with the oxygen electrode, and a solid oxide electrolyte between the oxygen electrode and the counter electrode. Methods of using such electrochemical devices are also provided, comprising exposing the oxygen electrode to a fluid comprising O 2 under conditions to induce the reaction O 2 +4e − →2O 2− , or to a fluid comprising O 2− under conditions to induce the reaction 2O 2− →O 2 +4e − .

Zhang, Shan-Lin↗

Closed Loop Geothermal Working Group: GeoCLUSTER App, Subsurface Simulation Results, and Publications

To better understand the heat production, electricity generation performance, and economic viability of closed-loop geothermal systems in hot-dry rock, the Closed-Loop Geothermal Working Group -- a consortium of several national labs and academic institutions has tabulated time-dependent numerical solutions and levelized cost results of two popular closed-loop heat exchanger designs (u-tube and co-axial). The heat exchanger designs were evaluated for two working fluids (water and supercritical CO2) while varying seven continuous independent parameters of interest (mass flow rate, vertical depth, horizontal extent, borehole diameter, formation gradient, formation conductivity, and injection temperature). The corresponding numerical solutions (approximately 1.2 million per heat exchanger design) are stored as multi-dimensional HDF5 datasets and can be queried at off-grid points using multi-dimensional linear interpolation. A Python script was developed to query this database and estimate time-dependent electricity generation using an organic Rankine cycle (for water) or direct turbine expansion cycle (for CO2) and perform a cost assessment. This document aims to give an overview of the HDF5 database file and highlights how to read, visualize, and query quantities of interest (e.g., levelized cost of electricity, levelized cost of heat) using the accompanying Python scripts. Details regarding the capital, operation, and maintenance and levelized cost calculation using the techno-economic analysis script are provided. This data submission will contain results from the Closed Loop Geothermal Working Group study that are within the public domain, including publications, simulation results, databases, and computer codes. GeoCLUSTER is a Python-based web application created using Dash, an open-source framework built on top of Flask that streamlines the building of data dashboards. GeoCLUSTER provides users with a collection of interactive methods for streamlining the exploration and visualization of an HDF5 dataset. The GeoCluster app and database are contained in the compressed file geocluster_vx.zip, where the "x" refers to the version number. For example, geocluster_v1.zip is Version 1 of the app. This zip file also contains installation instructions. **To use the GeoCLUSTER app in the cloud, click the link to "GeoCLUSTER on AWS" in the Resources section below. To use the GeoCLUSTER app locally, download the geocluster_vx.zip to your computer and uncompress this file. When uncompressed this file comprises two directories and the geocluster_installation.pdf file. The geo-data app contains the HDF5 database in condensed format, and the GeoCLUSTER directory contains the GeoCLUSTER app in the subdirectory dash_app, as app.py. The geocluster_installation.pdf file provides instructions on installing Python, the needed Python modules, and then executing the app.

15 GEOTHERMAL ENERGY↗

Tabulated Database of Closed-Loop Geothermal Systems Performance for Cloud-Based Technical and Economic Modeling of Heat Production and Electricity Generation: Preprint

To better understand the heat production, electricity generation performance and economic viability of closed loop geothermal systems in hot-dry-rock, the Closed Loop Geothermal Group, a consortium of several national labs and academic institutions has tabulated time-dependent numerical solutions and levelized cost results of two popular closed loop heat exchanger designs (u-tube and co-axial). The heat exchanger designs were evaluated for two working fluids (water and super-critical CO2) while varying seven continuous independent parameters of interest (i.e., mass flow rate, vertical depth, horizontal extent, borehole diameter, formation gradient, formation conductivity, and injection temperature). The corresponding numerical solutions (approximately 1.2 million per heat exchanger design) are stored as multi-dimensional HDF5 datasets and can be queried at off-grid points using multi-dimensional linear interpolation. A Python script was developed to query this database and estimate time-dependent electricity generation using an Organic Rankine cycle (for water) or direct turbine expansion cycle (for CO2) and perform a cost assessment. This document aims to give an overview of the HDF5 database file and highlights how to read, visualize, and query quantities of interest (e.g., levelized cost of electricity, levelized cost of heat) using the accompanying python scripts. Details regarding the capital, operation, and maintenance and levelized cost calculation using the TEA (techno-economic analysis) script are provided.

co-axial↗

A time-dependent gyro-kinetic model of thermal ion upflows in the high-latitude F region

Ample evidence supports the significance of the high-latitude ionospheric contribution to magnetospheric plasma. Assuming flux conservation along a flux tube, the upward field-aligned ion flows observed in the magnetosphere require high-latitude ionospheric field-aligned ion upflows of the order of 10(exp 8) to 10(exp 9)/sq cm/s. Since radar and satellite observations of high-latitude F region flows at times exceed this flux requirement by an order of magnitude, the thermal ionospheric upflows are not simply the ionospheric response to a magnetospheric flux requirement. Several ionospheric ion upflow mechanisms have been proposed, but simulations based on fluid theory do not reproduce all the observed features of ionospheric ion upflows. Certain asymmetries in the statistical morphology of high-latitude F region ion upflows suggest that the ion upflows may be generated by ion-neutral frictional heating. We developed a single-component (O(+)), time-dependent gyro-kinetic model of the high-latitude F region response to frictional heating in which the neutral exobase is a discontinuous boundary between fully collisional and collisionless plasmas. The concept of a discontinuous neutreal exobase and the assumption of a constant and uniform polarization electric field reduce the ion velocity distribution function, from which we can compute the ion density, parallel velocity, parallel and perpendicular temperature, and parallel flux. Using our model, we simulated the response of a convecting flux tube between 500 km and 2500 km to various frictional heating inputs; the results were both qualitatively and quantitatively different from fluid model results, which may indicate an inadequacy of the fluid theory approach. The gyro-kinetic frictional heating model responses to the various simulations were qualitatively similar: (1) initial perturbations of all the modeled parameters propagated rapidly up the flux tube, (2) transient values of the ion parallel velocity, temperature, and flux exceeded 3 km/s, 2 x 10(exp 4) K, and 10(exp 9)/sq cm/s, respectively, (3) a second transient regime developed wherein the parallel temperature drops to very low values (a few hundred Kelvins), and (4) well after heating ceased, large parallel temperatures and large downward parallel velocities and fluxes developed as the flux tube slowly returned to diffusive equilibrium. The ion velocity distributions during the simulation are often non-Maxwellian and are sometimes composed of two distinct ion populations.

Loranc, M.↗

Dynamic model based on voltage transfer curve for pattern formation in dielectric barrier glow discharge

Simulation work is very important for understanding the formation of self-organized discharge patterns. Previous works have witnessed different models derived from other systems for simulation of discharge pattern, but most of these models are complicated and time-consuming. In this paper, we introduce a convenient phenomenological dynamic model based on the basic dynamic process of glow discharge and the voltage transfer curve (VTC) to study the dielectric barrier glow discharge (DBGD) pattern. VTC is an important characteristic of DBGD, which plots the change of wall voltage after a discharge as a function of the initial total gap voltage. In the modeling, the combined effect of the discharge conditions is included in VTC, and the activation-inhibition effect is expressed by a spatial interaction term. Besides, the model reduces the dimensionality of the system by just considering the integration effect of current flow. All these greatly facilitate the construction of this model. Numerical simulations turn out to be in good accordance with our previous fluid modeling and experimental result.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of Play Fairway Analysis of the geothermal potential of Camas Prairie, south-central Idaho, by an exploration well

Abstract Play Fairway Analysis (PFA) methodology was adapted for geothermal exploration at Camas Prairie, Idaho. Geophysical data, structural and geologic mapping, volcanic rock ages and vent locations, and the distribution of thermal springs and wells all indicated a relatively high geothermal potential along the southern margin of the Prairie. An exploration well (USU Camas-1) was drilled to a depth of 618.3 m to validate the PFA. A permeable zone was encountered at ~ 357.5 m with a maximum measured temperature of ~ 80 °C, which was suppressed following the injection of cold water. A moderate transmissivity of ~ 0.25–1 cm 2 /s estimated from an injection test as well a seasonal artesian flow at ~ 0.7 L/s corroborate the presence of a permeable zone. The existence of a lacustrine clay seal was confirmed near the bottom of the basin-fill sediment occupying the upper 314 m of the well. Geothermometers suggest the USU Camas-1 well water equilibrated at a reservoir temperature of ~ 120 °C. Based on the locations of both thermal and cold wells, geothermal fluids appear to be flowing upward along one or both of two fault systems. The presence of young basalts and elevated helium isotope ratios suggest that the heat source of Camas Prairie is magmatic. However, the faults may be acting as a conduit for geothermal fluids to rise from great depth without a shallow magmatic source being present. Camas Prairie is a promising area for geothermal development, but the relatively low reservoir temperatures indicate this resource may not be suitable for electric generation. Perhaps the best use would be for heating.

Lachmar, Thomas E. (ORCID:0000000249640119)↗

The Co-Firing of Pine Biomass and Waste Coal in 100 and 600 MW Power Plants: A Sustainable Approach to Reduce GHG Emissions

Climate change is a global issue that has gained much attention recently. Co-firing biomass with coal/waste coal reduces the electricity sector’s GHG emissions sustainably. This study uses commercial software to model waste coal and biomass co-firing in 100 MW and 600 MW power plants. The objective is to assess the effects of fluid types (subcritical and supercritical), plant capacities (100 MW and 600 MW), boiler types (pulverized coal and circulating fluidized bed boilers), biomass and waste coal co-firing ratios (0:100, 20:80, 40:60, 60:40, 80:20, and 100:0), and carbon capture and storage efficiencies (0%, 90%, 95%, and 97%) on performance parameters such as net plant efficiency, heat rate, net plant CO2 and SO2, and particulate matter emissions. The feedstocks selected for this investigation include anthracite waste coal and loblolly pine biomass. As the biomass fraction increases from 0% to 100%, co-fired power plants net efficiency increases by 3–8%. Supercritical plants had a 6% higher net plant efficiency than the subcritical plants. The study found that the biomass’s high heating value decreased the fuel flow rate and reduced plant CO2 emissions by 10–16%. With 100% biomass power plant feed and 90% carbon capture and storage efficiency, CO2 emissions drop by 83% and SO2 and PM emissions drop to zero.

Bhoi, Prakashbhai R. (ORCID:0000000333104888)↗

Statistical formulation of one-dimensional electron fluid turbulence

A one-dimensional electron fluid model is investigated using the mathematical methods of modern fluid turbulence theory. Nondissipative equilibrium canonical distributions are determined in a phase space whose coordinates are the real and imaginary parts of the Fourier coefficients for the field variables. Spectral densities are calculated, yielding a wavenumber electric field energy spectrum proportional to 1/k squared for large wavenumbers. The equations of motion are numerically integrated and the resulting spectra are found to compare well with the theoretical predictions.

Fyfe, D.↗

NASA Tech Briefs, April 2008

Topics covered include: Gas Sensors Based on Coated and Doped Carbon Nanotubes; Tactile Robotic Topographical Mapping Without Force or Contact Sensors; Thin-Film Magnetic-Field-Response Fluid-Level Sensor for Non-Viscous Fluids; Progress in Development of Improved Ion-Channel Biosensors; Simulating Operation of a Complex Sensor Network; Using Transponders on the Moon to Increase Accuracy of GPS; Controller for Driving a Piezoelectric Actuator at Resonance; Coaxial Electric Heaters; Dual-Input AND Gate From Single-Channel Thin-Film FET; High-Density, High-Bandwidth, Multilevel Holographic Memory; Fabrication of Gate-Electrode Integrated Carbon-Nanotube Bundle Field Emitters; Hydroxide-Assisted Bonding of Ultra-Low-Expansion Glass; Photochemically Synthesized Polyimides; Optimized Carbonate and Ester-Based Li-Ion Electrolytes; Compact 6-DOF Stage for Optical Adjustments; Ultrasonic/Sonic Impacting Penetrators; Miniature, Lightweight, One-Time-Opening Valve; Supplier Management System; Improved CLARAty Functional-Layer/Decision-Layer Interface; JAVA Stereo Display Toolkit; Remote-Sensing Time Series Analysis, a Vegetation Monitoring Tool; PyPele Rewritten To Use MPI; Data Assimilation Cycling for Weather Analysis; Hydrocyclone/Filter for Concentrating Biomarkers from Soil; Activating STAT3 Alpha for Promoting Healing of Neurons; and Probing a Spray Using Frequency-Analyzed Light Scattering.

Source record↗

Modeling ARRM Xenon Tank Pressurization Using 1D Thermodynamic and Heat Transfer Equations

As a first step in understanding what ground support equipment (GSE) is required to provide external cooling during the loading of 5,000 kg of xenon into 4 aluminum lined composite overwrapped pressure vessels (COPVs), a modeling analysis was performed using Microsoft Excel. The goals of the analysis were to predict xenon temperature and pressure throughout loading at the launch facility, estimate the time required to load one tank, and to get an early estimate of what provisions for cooling xenon might be needed while the tanks are being filled. The model uses the governing thermodynamic and heat transfer equations to achieve these goals. Results indicate that a single tank can be loaded in about 15 hours with reasonable external coolant requirements. The model developed in this study was successfully validated against flight and test data. The first data set is from the Dawn mission which also utilizes solar electric propulsion with xenon propellant, and the second is test data from the rapid loading of a hydrogen cylindrical COPV. The main benefit of this type of model is that the governing physical equations using bulk fluid solid temperatures can provide a quick and accurate estimate of the state of the propellant throughout loading which is much cheaper in terms of computational time and licensing costs than a Computation Fluid Dynamics (CFD) analysis while capturing the majority of the thermodynamics and heat transfer.

Xenon storage↗

Modeling Xenon Tank Pressurization using One-Dimensional Thermodynamic and Heat Transfer Equations

As a first step in understanding what ground support equipment (GSE) is required to provide external cooling during the loading of 5,000 kg of xenon into 4 aluminum lined composite overwrapped pressure vessels (COPVs), a modeling analysis was performed using Microsoft Excel. The goals of the analysis were to predict xenon temperature and pressure throughout loading at the launch facility, estimate the time required to load one tank, and to get an early estimate of what provisions for cooling xenon might be needed while the tanks are being filled. The model uses the governing thermodynamic and heat transfer equations to achieve these goals. Results indicate that a single tank can be loaded in about 15 hours with reasonable external coolant requirements. The model developed in this study was successfully validated against flight and test data. The first data set is from the Dawn mission which also utilizes solar electric propulsion with xenon propellant, and the second is test data from the rapid loading of a hydrogen cylindrical COPV. The main benefit of this type of model is that the governing physical equations using bulk fluid solid temperatures can provide a quick and accurate estimate of the state of the propellant throughout loading which is much cheaper in terms of computational time and licensing costs than a Computation Fluid Dynamics (CFD) analysis while capturing the majority of the thermodynamics and heat transfer.

Thermodynamic tank modeling↗

EVALUATION OF ORGANIC RANKINE CYCLES IN AN AIR-BRAYTON COMBINED CYCLE FOR MICROREACTOR APPLICATIONS

Microreactors can be used to provide electrical power up to 10 MWe for emergency situations, remote areas, or military applications. Combined cycles comprised of an air Brayton topping cycle and an Organic Rankine bottoming cycle were evaluated in HYSYS using different working fluids in the bottoming cycle and in different ambient environments. The results suggest that a bottoming ORC can increase the thermal efficiency of the air Brayton cycle up to 40.22%. Exergy analysis was also performed on the combined cycle along with a simple validation of HYSYS on the bottoming cycle. The exergy analysis shows that of available work, most is lost at the reactor or turned into work at the topping cycle. A rudimentary capital cost estimate showed that adding a bottoming cycle is not prohibitively expensive.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cartridge-based thermoelectric systems

Cartridge-based thermoelectric assemblies and systems are provided which include at least one shunt configured to extend around a conduit, a plurality of thermoelectric elements in thermal communication and in electrical communication with the at least one shunt with at least a portion of the at least one shunt sandwiched between the at least one first thermoelectric element and the at least one second thermoelectric element. The thermoelectric elements are electrically isolated from the conduit. The thermoelectric assemblies and systems further include at least one heat exchanger in thermal communication with the at least one shunt and configured to be in thermal communication with a second fluid.

Poliquin, Eric↗

Self-similar and diffusive expansion of nonextensive plasmas

Exact analytical self-similar solution is presented for free collisionless expansion of a two-component plasma of inertial ions and nonextensive electrons into vacuum, using the generalized nonextensive velocity distribution for electrons. Furthermore, a hydrodynamic model of plasma expansion in the presence of the ambipolar diffusion caused by collisions among the plasma species, such as electrons and ions, is developed and a Fokker-Planck-like generalized diffusion equation for steady-state expansion of a nonextensive electron-ion plasma is derived. For the case of generalized statistics and in the absence of particle diffusion, the density, velocity, electric potential, and field of expansion profiles are exactly obtained and studied in terms of the self-similar parameter. It is found that superthermal electrons lead to an accelerated expansion of plasma compared to that of Maxwellian electrons. It is also revealed that the nonextensivity parameter plays a fundamental role on the density, velocity, electric potential, and field configuration of the expansion. Therefore, one is able to distinguish three different regimes q < 1, q = 1, and q > 1 for expansion corresponding to sub-nonextensive, extensive, and super-nonextensive statistical profiles for electrons, respectively. Current research can provide useful information and suggests techniques for investigation of the involved statistical mechanism on the role of the energetic electron fluid in the expansion of plasma in strong pulsed laser-matter interaction experiments. It is also shown that the particle diffusion expansion mechanism becomes more dominant for relatively large values of the nonextensivity parameter, q.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic colloidal assembly pathways via low dimensional models

Here we construct a low-dimensional Smoluchowski model for electric field mediated colloidal crystallization using Brownian dynamic simulations, which were previously matched to experiments. Diffusion mapping is used to infer dimensionality and confirm the use of two order parameters, one for degree of condensation and one for global crystallinity. Free energy and diffusivity landscapes are obtained as the coefficients of a low-dimensional Smoluchowski equation to capture the thermodynamics and kinetics of microstructure evolution. The resulting low-dimensional model quantitatively captures the dynamics of different assembly pathways between fluid, polycrystal, and single crystals states, in agreement with the full N-dimensional data as characterized by first passage time distributions. Numerical solution of the low-dimensional Smoluchowski equation reveals statistical properties of the dynamic evolution of states vs. applied field amplitude and system size. The low-dimensional Smoluchowski equation and associated landscapes calculated here can serve as models for predictive control of electric field mediated assembly of colloidal ensembles into two-dimensional crystalline objects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the sound speed in dense fluid deuterium along the cryogenic liquid Hugoniot

Many experimental studies, spanning several decades of research and using various dynamic compression schemes, have been conducted to investigate cryogenic liquid deuterium under strong shock compression. The consensus emerging from these studies is that of a progressive dissociation of the D 2 molecules into an electrically conducting, atomic plasma, when subjected to shock pressures exceeding ~50 GPa. While state-of-the-art numerical simulations based on density-functional-theory or quantum Monte-Carlo techniques capture this behavior quite well, subtle differences subsist between these simulations and the available experimental data regarding the pressure-density compressibility. Here, leveraging a recently developed analysis method for high-resolution Doppler interferometric velocity data, we present Eulerian sound speed measurements in compressed deuterium to shock pressures between 50 and 200 GPa. These results, extracted from laser-driven shockwave experiments, are found to agree with several of the most accurate equation of state models for deuterium at those conditions up to ~150 GPa. However, the data indicate that these models fail to reproduce the experimentally observed sound speed at higher pressures, approaching 200 GPa. In particular, we unveil a discrepancy between the experimental results and the equation of state model that is most commonly used in inertial confinement fusion at the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗