Integration Study of Converter-Interfaced Combined Heat and Power Plants

Combined Heat and Power (CHP) systems, as a proven technology, provide numerous benefits to the plant owner by saving electricity bill, reducing carbon dioxide emissions, and improving electricity service reliability. However, their integration into the distribution grid faces many barriers including the complexity of grid code requirements and the lack of technical expertise in commercial and small industrial plants to interface with the utility and accelerate the interconnection process. To solve these issues, this study proposes a converter-interfaced solution for CHP integration. Simulations including various fault scenarios and load flow under different grid conditions are carried out to compare technical performances of the proposed solution with directly-coupled CHP. Results show that the generator size of converter-interfaced CHP can be reduced by approximately 25% and it also provides advantageous features such as reduced stress level under fault conditions and a better dynamic stability margin. In addition, a power factor controller is designed and reactive power from CHP is dispatched in such a way that the CHP plant is compliant with power factor requirements from utilities under all operating conditions.

Converter, Combined heat and power, Distributed en↗

Control of Low-Inertia Power Systems

Electric power systems are undergoing an unprecedented transition from fossil fuel–based power plants to low-inertia systems that rely predominantly on power electronics and renewable energy resources. This article reviews the resulting control challenges and modeling fallacies, at both the device and system level, and focuses on novel aspects or classical concepts that need to be revised in light of the transition to low-inertia systems. To this end, we survey the literature on modeling of low-inertia systems, review research on the control of grid-connected power converters, and discuss the frequency dynamics of low-inertia systems. Moreover, we discuss system-level services from a control perspective. Overall, we conclude that the system-theoretic mindset is essential to bridge different research communities and understand the complex interactions of power electronics, electric machines, and their controls in large-scale low-inertia power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EVSE DERMS Controls [SWR-26-010]

An MQTT (Message Queuing Telemetry Transport) and OCPP (Open Charge Point Protocol) based remote smart charging controller framework for AC Electric Vehicle Supply Equipments (EVSEs). The code in this repo allows for the National Laboratory of the Rockies (NLR) controls to interface with the real Distributed Energy Resource Management System (DERMS) and EVSEs in NLR's ESIF Optimization and Control Laboratory (OCL). Different charge management algorithms can be tested to determine which power allocation method is most effective with the overall goal of demonstrating clear and well documented test results as well as providing functional control algorithms which could be utilized to provide effective smart charge management (SCM) at EV charging stations. Different power allocation methods are programmed in lab_demo_controller.py and include allocation based on first come first served, equal sharing, state of charge (SOC), priority factors, and behind the meter control methods.

Panossian, Nadia [National Laboratory of the Rocki↗

2020 Standard Scenarios Report: A U.S. Electricity Sector Outlook

This report summarizes the results of 47 forward-looking 'standard scenarios' of the U.S. power sector simulated by the National Renewable Energy Laboratory (NREL) using the Regional Energy Deployment System (ReEDS) and Distributed Generation (dGen) capacity expansion models. The annual Standard Scenarios, which are now in their sixth year, have been designed to capture a range of possible power system futures considering a variety of factors that impact power sector evolution.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Space station power system requirements

Presented is an overview of the requirements on which the Space Station Electric Power System is based as well as a summary of the design itself. The current design, which is based on silicon photovoltaic arrays, NiH2 batteries, and 20 kHz distribution technology, meets all of the requirements.

Dunning, John W., Jr.↗

Space Station power system requirements

Presented is an overview of the requirements on which the Space Station Electric Power System is based as well as a summary of the design itself. The current design, which is based on silicon photovoltaic arrays, NiH2 batteries, and 20 kHz distribution technology, meets all of the requirements.

Dunning, John W., Jr.↗

Design Concepts to Meet EASA SC-VTOL-01 Single Failure Criteria

The objective of the current work is to discuss European Union Aviation Safety Agency (EASA) SC-VTOL-01 single failure criteria, VTOL.2250(c). Prior studies have developed concept distributed propulsion and flight control (DPFC) system architectures and found they comply with EASA SC-VTOL-01 probabilistic failure criteria, VTOL.2510(a). Prior work developed two all-electric DPFC systems utilized in a quadrotor concept aircraft developed by the National Aeronautics and Space Administration (NASA); one uses interconnecting shafts and gearboxes to interconnect redundant motors with each rotor system and the other uses gearboxes to connect redundant motors locally, near each rotor. Common between the two electric DPFC systems were rotor shafts, epicyclic systems, and motors. The current work explores Category I failures in drive systems, relevant research to support fail-safe design practices for gear systems, research and adjacent industry trends in motor fail-safety and reliability, and proposed design concepts to comply with VTOL.2250(c). Continued research in fail-safe design concepts and design guidance will benefit eVTOL and conventional rotorcraft, alike. Continued research in these areas will benefit eVTOL certification against SC-VTOL-01, and could optimistically translate to more widespread adoption of similar fail-safe design concepts into new rotorcraft designs certified against CS-29.

Rotorcraft↗

Distributed electric field sensing using fibre optics in borehole environments

In the past decade, rapid advances in distributed optical fibre sensing technologies have made it possible to record various geophysical data (e.g. strain, temperature and pressure) continuously in both time and space along the fibre, providing an unprecedented quantity and spatial density of data compared to traditional geophysical measurements as well as reducing data acquisition cost. To date, no distributed fibre-based electromagnetic field sensing system has been implemented although electromagnetic sensing could have a broad range of applications to geophysical imaging and monitoring in borehole environments. The goal of this paper is to provide a theoretical feasibility study regarding the design and use of an electromagnetic sensing optical fibre for geophysical applications. First, we present the sensitivity analysis of a ‘hypothetical’ optical fibre coated with polyvinylidene fluoride, a polymer that provides relatively high piezoelectric properties, yet unlike ceramics, is flexible. Next, using a two-dimensional electromagnetic modelling algorithm, we simulate the earth electric-field-to-fibre-strain transfer function and estimate the theoretical sensitivity of the optical fibre to electric fields. Given the state-of-the-art distributed acoustic sensing strain sensitivities in the picometres strain range, our numerical modelling analysis suggests that a perfectly coupled polyvinylidene fluoride–coated optical fibre can measure electric field values in the mV/m to V/m amplitude range. We then apply a cylindrically symmetric modelling algorithm to simulate numerical models demonstrating the applicability of such a fibre in an oilfield environment. Scenarios investigated employ an electric field source and suggest that the measurements can be used to distinguish the oil versus water ratio with a fibre mounted inside a producing steel cased oil well as well as distinguishing between brine and hydrocarbon filled reservoir zones with a fibre located outside of the casing.

58 GEOSCIENCES↗

Design of Distributed Mail-Slot Propulsion System on a Hybrid Wingbody Aircraft

This paper deals with designing a thrust distribution strategy when a Turboelectric Distributed Propulsion (TeDP) system of 16 embedded propulsors is installed on an aerodynamically optimized hybrid wing-body configuration. This HWB previously designed to satisfy conditions of trim, longitudinally static stability and specific cargo space is employed as the baseline configuration for the current study of seeking an optimal propulsion/power system. According to the nature of the entrance flow condition for each distributed propulsion passage in hybrid wing-body aircraft, the ingested boundary layer thickness differs and results in different propulsive reaction. An optimal distribution of thrust and power output is determined by how the system utilizes the propulsive characteristics of each passage. The design space and the number of design variables are selected and described accordingly. An actuator disk model is employed to model thrust generation and shaft power from the propulsor. To carry out the optimization of the propulsion/power system on a computationally expensive CFD model, a Kriging method in conjunction with a Genetic Algorithm (GA) is applied. Throughout the design process, the propulsion performances of the sampled propulsion/power system are analyzed and compared to those of a clean flow engine. The performance metrics includes mass flow rate, fan pressure ratio besides the thrust and shaft power. Minimization of total shaft power from the distributed engine is performed at multiple thrust levels. The benefit of boundary layer ingestion propulsion system is quantified via comparison of thrust equivalent, shaft power and mass flow equivalent clean flow engines with CFD based system design.

Hybrid Wingbody↗

Energy Systems Integration Facility Stewardship Summary: Fiscal Year 2022

A summary of NREL's good stewardship of the nationally unique Energy Systems Integration Facility (ESIF) highlighting performance metrics, infrastructure and capability upgrades, and examples of R&D impact. In fiscal year 2022, ESIF researchers made breakthroughs in everything from long-duration energy storage and cybersecurity visualizations to a world record in heavy-duty hydrogen vehicle fueling, and built out research assets to advance microgrid operation and controls, renewable hydrogen production, electric vehicles, energy-efficient buildings, and more.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Satellite control of electric power distribution

An L-band frequencies satellite link providing the medium for direct control of electrical loads at individual customer sites from remote central locations is described. All loads supplied under interruptible-service contracts are likely condidates for such control, and they can be cycled or switched off to reduce system loads. For every kW of load eliminated or deferred to off-peak hours, the power company reduces its need for additional generating capacity. In addition, the satellite could switch meter registers so that their readings automatically reflected the time of consumption. The system would perform load-shedding operations during emergencies, disconnecting large blocks of load according to predetermined priorities. Among the distribution operations conducted by the satellite in real time would be: load reconfiguration, voltage regulation, fault isolation, and capacitor and feeder load control.

Bergen, L.↗

Proposal and Development of a High Voltage Variable Frequency Alternating Current Power System for Hybrid Electric Aircraft

The development of ultra-efficient commercial vehicles and the transition to low-carbon emission propulsion are seen as thrust paths within NASA Aeronautics. A critical enabler to these paths comes in the form of hybrid-electric propulsion systems. For megawatt-class systems, the best power system topology for these hybrid-electric propulsion systems is debatable. Current proposals within NASA and the Aero community suggest using a combination of AC and DC for power transmission. This paper proposes an alternative to the current thought model through the use of a primarily high voltage AC power generation, transmission, and distribution systems, supported by the Convergent Aeronautics Solutions (CAS) Project. This system relies heavily on the use of dual-fed induction machines, which provide high power densities, minimal power conversion, and variable speed operation. The paper presents background on the project along with the system architecture, development status and preliminary results.

Propulsion↗

Direct Drive Hall Thruster System Development

The sta:us of development of a Direct Drive Ha!! Thruster System is presented. 13 the first part. a s:udy of the impacts to spacecraft systems and mass benefits of a direct-drive architecture is reviewed. The study initially examines four cases of SPT-100 and BPT-4000 Hall thrusters used for north-south station keeping on an EXPRESS-like geosynchronous spacecraft and for primary propulsion for a Deep Space- 1 based science spacecraft. The study is also extended the impact of direct drive on orbit raising for higher power geosynchronous spacecraft and on other deep space missions as a function of power and delta velocity. The major system considerations for accommodating a direct drive Hall thruster are discussed, including array regulation, system grounding, distribution of power to the spacecraft bus, and interactions between current-voltage characteristics for the arrays and thrusters. The mass benefit analysis shows that, for the initial cases, up to 42 kg of dry mass savings is attributable directly to changes in the propulsion hardware. When projected mass impacts of operating the arrays and the electric power system at 300V are included, up to 63 kg is saved for the four initial cases. Adoption of high voltage lithium ion battery technology is projected to further improve these savings. Orbit raising of higher powered geosynchronous spacecraft, is the mission for which direct drive provides the most benefit, allowing higher efficiency electric orbit raising to be accomplished in a limited period of time, as well as nearly eliminating significant power processing heat rejection mass. The total increase in useful payload to orbit ranges up to 278 kg for a 25 kW spacecraft, launched from an Atlas IIA. For deep space missions, direct drive is found to be most applicable to higher power missions with delta velocities up to several km/s , typical of several Discovery-class missions. In the second part, the status of development of direct drive propulsion power electronics is presented. The core of this hardware is the heater-keeper-magnet supply being qualified for the BPT-4000 by Aerojet. A breadboard propulsion power unit is in fabrication and is scheduled for delivery late in 2003.

Hoskins, W. Andrew↗

Multiscale Electricity Modeling for Evaluating Carbon Capture and Sequestration Technologies (MEME-CCS)

This effort employs and adapts a rigorous multiscale electricity modeling platform at the National Renewable Energy Laboratory (NREL) to evaluate carbon capture and sequestration (CCS) and negative emissions technologies (NET) from the ARPA-E FLECCS program. NREL's modeling platform includes the Regional Energy Deployment System (ReEDS) electric sector capacity expansion model, which projects future electricity generation mixes at sub-state-level resolution that are downscaled to the unit-level to enable hourly, zonal or nodal electricity production cost modeling in the PLEXOS model. The ReEDS-PLEXOS modeling suite is well-established for examining electric sector futures with high renewable energy penetrations, energy storage, electrification, and distributed generation. The key advancement proposed herein utilizes collaboration with CCS experts at the University of Wyoming (U.WY) and the FLECCS technology development teams to create innovative methods for representing CCS and NET in the ReEDS and PLEXOS models. Expanded technology options and new operational parameterizations are integrated into these models to allow an unprecedented combination of scope and resolution for exploring the future of CCS and NET. The resulting capabilities permit wide-ranging scenario analysis to assess CCS and NET deployment under alternative scenarios of CO2 prices and competitiveness of flexible CCS and NET technologies. We demonstrate sample deployment and operational outcomes to show how these models are being used to assess the future potential for FLECCS technologies and their impacts on the U.S. electricity system. These products will help an emerging CCS/NET industry in the United States by providing economics-driven guidance to technology developers while informing policy and investment decisions in the public and private sectors.

capacity expansion↗

Storm-DEPART (Damage Estimate Prediction and Recovery Tool)

Storm-DEPART (Damage Estimate Prediction and Restoration Tool): Each year hurricanes and tropical storms in the United States damage critical infrastructure assets, disrupt the services they provide, and cause millions to billions of dollars in economic impacts due to extended recovery times. The Storm-DEPART tool and analytical output enable more impactful data-driven decision-making capabilities and strengthen national-level disaster preparedness, response, and recovery. Storm-DEPART, built through multi-month collaboration between Entergy and INL, combines Entergy’s critical infrastructure inventory data with weather forecasts to predict damages to Electric utility’s assets due to natural disasters and the estimated recovery support needed, including time, materials, and resource allocation. In the event of an approaching hurricane, this innovative solution can assess potential damage to power generation capacity, transmission grids, distribution networks, and communications assets from wind bands, storm surge, and flooding. With more effective predictions, Entergy can more efficiently allocate resources to mitigate impacts and optimize recovery for customers. Storm-DEPART also allows Electric utilities the ability to apply a planning scenario and model expected damage to better inform infrastructure restoration needs leading to enhance system resiliency. The technology is fully transferrable to other electric utilities with the same damage estimating challenges. The INL team is working on the evolution of Storm-DEPART to include ice event damage prediction framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic conversion of solar generated heat to electricity

The effort undertaken during this program led to the selection of the water-superheated steam (850 psig/900 F) crescent central receiver as the preferred concept from among 11 candidate systems across the technological spectrum of the dynamic conversion of solar generated heat to electricity. The solar power plant designs were investigated in the range of plant capacities from 100 to 1000 Mw(e). The investigations considered the impacts of plant size, collector design, feed-water temperature ratio, heat rejection equipment, ground cover, and location on solar power technical and economic feasibility. For the distributed receiver systems, the optimization studies showed that plant capacities less than 100 Mw(e) may be best. Although the size of central receiver concepts was not parametrically investigated, all indications are that the optimal plant capacity for central receiver systems will be in the range from 50 to 200 Mw(e). Solar thermal power plant site selection criteria and methodology were also established and used to evaluate potentially suitable sites. The result of this effort was to identify a site south of Inyokern, California, as typically suitable for a solar thermal power plant. The criteria used in the selection process included insolation and climatological characteristics, topography, and seismic history as well as water availability.

Powell, J. C.↗