High Current ESD Test of Advanced Triple Junction Solar Array Coupon

A test was conducted on an Advanced Triple Junction (ATJ) coupon that was part of a risk reduction effort in the development of a high-powered solar array design by SSL. The ATJ coupon was a small, 4-cell, two-string configuration that has served as the basic test coupon design used in previous SSL environmental aging campaigns. The coupon has many attributes of the flight design; e.g., substrate structure with graphite face sheets, integrated by-pass diodes, cell interconnects, RTV grout, wire routing, etc. The objective of the present test was to evaluate the performance of the coupon after being subjected to induced electrostatic discharge testing at two string voltages (100 V, 150 V) and four array current (1.65 A, 2.0 A, 2.475 A, and 3.3 A). An ESD test circuit, unique to SSL solar array design, was built that simulates the effect of missing cells and strings in a full solar panel with special primary arc flashover circuitry. A total of 73 primary arcs were obtained that included 7 temporary sustained arcs (TSA) events. The durations of the TSAs ranged from 50 μs to 2.9 ms. All TSAs occurred at a string voltage of 150 V. Post-test Large Area Pulsed Solar Simulator (LAPSS), Dark I-V, and By-Pass Diode tests showed that no degradation occurred due to the TSA events. In addition, the post-test insulation resistance measured was > 50 G-ohms between cells and substrate. These test results indicate a robust design for application to a high-current, high-power mission application.

Wright, K. H.↗

High Current ESD Test of Advanced Triple Junction Solar Array Coupon

A test was conducted on an Advanced Triple Junction (ATJ) coupon that was part of a risk reduction effort in the development of a high-powered solar array design by SSL. The ATJ coupon was a small, 4-cell, two-string configuration that has served as the basic test coupon design used in previous SSL environmental aging campaigns. The coupon has many attributes of the flight design; e.g., substrate structure with graphite face sheets, integrated by-pass diodes, cell interconnects, RTV grout, wire routing, etc. The objective of the present test was to evaluate the performance of the coupon after being subjected to induced electrostatic discharge testing at two string voltages (100 V, 150 V) and four array current (1.65 A, 2.0 A, 2.475 A, and 3.3 A). An ESD test circuit, unique to SSL solar array design, was built that simulates the effect of missing cells and strings in a full solar panel with special primary arc flashover circuitry. A total of 73 primary arcs were obtained that included 7 temporary sustained arcs (TSA) events. The durations of the TSAs ranged from 50 micros to 2.9 ms. All TSAs occurred at a string voltage of 150 V. Post-test Large Area Pulsed Solar Simulator (LAPSS), Dark I-V, and By-Pass Diode tests showed that no degradation occurred due to the TSA events. In addition, the post-test insulation resistance measured was > 50 G-ohms between cells and substrate. These test results indicate a robust design for application to a high-current, high-power mission application.

Wright, Kenneth H., Jr.↗

P-doped organic semiconductor: Potential replacement for PEDOT:PSS in organic photodetectors

In this work, we present an alternative to the use of PEDOT:PSS as hole transport and electron blocking layers in organic photodetectors processed by solution. As Poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) is known to be sensitive to humidity, oxygen, and UV, removing this layer is essential for lifetime improvements. As a first step to achieving this goal, we need to find an alternative layer that fulfills the same role in order to obtain a working diode with similar or better performance. As a replacement, a layer of poly[(4,8-bis-(2-ethylhexyloxy)-benzo(1,2-b:4,5-b′)dithiophene)-2, 6-diyl-alt-(4-(2-ethylhexanoyl)-thieno[3,4-b]thiophene-)-2-6-diyl)] (PBDTTT-c) p-doped with the dopant tris-[1-(trifluoroethanoyl)-2-(trifluoromethyl)ethane-1,2-dithiolene] (Mo(tfd-COCF{sub 3}){sub 3}) is used. This p-doped layer effectively lowers the hole injection barrier, and the low electron affinity of the polymer prevents the injection of electrons into the active layer. We show similar device performance under light and the improvements of detection performance with the doped layer in comparison with PEDOT:PSS, leading to a detectivity of 1.9 × 10{sup 13} cm (Hz){sup 1/2} (W){sup −1}, competitive with silicon diodes used in imaging applications. Moreover, contrary to PEDOT:PSS, no localization of the p-doped layer is needed, leading to a diode active area defined by the patterned electrodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Baker-Barry Tunnel Lighting: Evaluation of a Potential GATEWAY Demonstrations Project

The U.S. Department of Energy is evaluating the Baker-Barry Tunnel as a potential GATEWAY Demonstrations project for deployment of solid-state lighting (SSL) technology. The National Park Service views this project as a possible proving ground and template for implementation of light-emitting diode (LED) luminaires in other tunnels, thereby expanding the estimated 40% energy savings from 132 MWh/yr to a much larger figure nationally. Most of the energy savings in this application is attributable to the instant-restrike capability of LED products and to their high tolerance for frequent on/off switching, used here to separately control either end of the tunnel during daytime hours. Some LED luminaires rival or outperform their high-intensity discharge (HID) counterparts in terms of efficacy, but options are limited, and smaller lumen packages preclude true one-for-one equivalence. However, LED products continue to improve in efficacy and affordability at a rate unmatched by other light source technologies; the estimated simple payback period of eight years (excluding installation costs and maintenance savings) can be expected to improve with time. The proposed revisions to the existing high-pressure sodium (HPS) lighting system would require slightly increased controls complexity and significantly increased luminaire types and quantities. In exchange, substantial annual savings (from reduced maintenance and energy use) would be complemented by improved quantity and quality of illumination. Although advanced lighting controls could offer additional savings, it is unclear whether such a system would prove cost-effective; this topic may be explored in future work.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-term stability of the Leksell Gamma Knife{sup ®} Perfexion™ patient positioning system (PPS)

Purpose: To assess the long-term mechanical stability and accuracy of the patient positioning system (PPS) of the Leksell Gamma Knife{sup ®} Perfexion™ (LGK PFX). Methods: The mechanical stability of the PPS of the LGK PFX was evaluated using measurements obtained between September 2007 and June 2011. Three methods were employed to measure the deviation of the coincidence of the radiological focus point (RFP) and the PPS calibration center point (CCP). In the first method, the onsite diode test tool with single diode detector was used together with the 4 mm collimator on a daily basis. In the second method, a service diode test tool with three diode detectors was used biannually at the time of the routine preventive maintenance. The test performed with the service diode test tool measured the deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. The third method employed the conventional film pin-prick method. This test was performed annually for the 4 mm collimator at the time of the routine annual QA. To estimate the effect of the patient weight on the performance of the PPS, the focus precision tests were also conducted with varying weights on the PPS using a set of lead bricks. Results: The average deviations measured from the 641 daily focus precision tests were 0.1 ± 0.1, 0.0 ± 0.0, and 0.0 ± 0.0 mm, respectively, for the 4 mm collimator in the X (left/right of the patient), Y (anterior/posterior of the patient), and Z (superior/inferior of the patient) directions. The average of the total radial deviations as measured during ten semiannual measurements with the service diode test tool were 0.070 ± 0.029, 0.060 ± 0.022, and 0.103 ± 0.028 mm, respectively for the central, long, and short diodes for the 4 mm collimator. Similarly, the average total radial deviations measured during the semiannual measurements for the 4, 8, and 16 mm collimators and using the central diode were 0.070 ± 0.029, 0.097 ± 0.025, 0.159 ± 0.028 mm, respectively. The average values of the deviations as obtained from the five annual film pin-prick tests for the 4 mm collimator were 0.10 ± 0.06, 0.06 ± 0.09, and 0.03 ± 0.03 mm for the X, Y, Z stereotactic directions, respectively. Only a minor change was observed in the total radial deviations of the PPS as a function of the simulated patient weight up to 202 kg on the PPS. Conclusions: Excellent long-term mechanical stability and high accuracy was observed for the PPS of the LGK PFX. No PPS recalibration or any adjustment in the PPS was needed during the monitored period of time. Similarly, the weight on the PPS did not cause any significant disturbance in the performance of the PPS for up to 202 kg simulated patient weight.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spin-optoelectronic devices based on hybrid organic-inorganic trihalide perovskites

Recently the hybrid organic-inorganic trihalide perovskites have shown remarkable performance as active layers in photovoltaic and other optoelectronic devices. However, their spin characteristic properties have not been fully studied, although due to the relatively large spin-orbit coupling these materials may show great promise for spintronic applications. Here we demonstrate spin-polarized carrier injection into methylammonium lead bromide films from metallic ferromagnetic electrodes in two spintronic-based devices: a ‘spin light emitting diode’ that results in circularly polarized electroluminescence emission; and a ‘vertical spin valve’ that shows giant magnetoresistance. In addition, we also apply a magnetic field perpendicular to the injected spins orientation for measuring the ‘Hanle effect’, from which we obtain a relatively long spin lifetime for the electrically injected carriers. Our measurements initiate the field of hybrid perovskites spin-related optoelectronic applications.

36 MATERIALS SCIENCE↗

Complete polarization of electronic spins in OLEDs

At low temperatures and high magnetic fields, electron and hole spins in an organic light-emitting diode become polarized so that recombination preferentially forms molecular triplet excited-state species. For low device currents, magnetoelectroluminescence perfectly follows Boltzmann activation, implying a virtually complete polarization outcome. As the current increases, the magnetoelectroluminescence effect is reduced because spin polarization is suppressed by the reduction in carrier residence time within the device. Under these conditions, an additional field-dependent process affecting the spin-dependent recombination emerges, possibly related to the build-up of triplet excitons and their interaction with free charge carriers. Suppression of the EL alone does not prove electronic spin polarization. We therefore probe changes in the spin statistics of recombination directly in a dual singlet-triplet emitting material, which shows a concomitant rise in phosphorescence intensity as fluorescence is suppressed. Finite spin-orbit coupling in these materials gives rise to a microscopic distribution in effective g-factors of electrons and holes, Δg, i.e., a distribution in Larmor frequencies. This Δg effect in the pair, which mixes singlet and triplet, further suppresses singlet-exciton formation at high fields in addition to thermal spin polarization of the individual carriers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of Kr gas mixing in oxygen plasma etching of ferroelectric poly(vinylidene fluoride-trifluoroethylene) copolymer films

Oxygen plasma etching characteristics of ferroelectric poly(vinylidene fluoride-trifluoroethylene) copolymer films are investigated. It was found in MFM (M: metal; F: ferroelectric) capacitors that plasma damage effects to the ferroelectric properties were insignificant when Au metal masks were used. On the contrary, C-V (capacitance versus voltage) characteristics were significantly degraded in plasma-etched MFIS (I: insulator; S: semiconductor) diodes. The origin of this phenomenon is speculated to be degradation of the SiO{sub 2}/Si interface by energetic oxygen ions and then mixing of Kr gas to the oxygen plasma is attempted to decrease the plasma damage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of charge-carrier diffusion length in the photosensing layer of HgCdTe n-on-p photovoltaic infrared focal plane array detectors

In the present paper, we propose a method for evaluating the bulk diffusion length of minority charge carriers in the photosensing layer of photovoltaic focal plane array (FPA) photodetectors. The method is based on scanning a strip-shaped illumination spot with one of the detector diodes at a low level of photocurrents j{sub ph} being registered; such scanning provides data for subsequent analysis of measured spot-scan profiles within a simple diffusion model. The asymptotic behavior of the effective (at j{sub ph} ≠ 0) charge-carrier diffusion length l{sub d} {sub eff} as a function of j{sub ph} for j{sub ph} → 0 inferred from our experimental data proved to be consistent with the behavior of l{sub d} {sub eff} vs j{sub ph} as predicted by the model, while the obtained values of the bulk diffusion length of minority carriers (electrons) in the p-HgCdTe film of investigated HgCdTe n-on-p FPA photodetectors were found to be in a good agreement with the previously reported carrier diffusion-length values for HgCdTe.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Response of asymmetric carbon nanotube network devices to sub-terahertz and terahertz radiation

Demand for efficient terahertz radiation detectors resulted in intensive study of the asymmetric carbon nanostructures as a possible solution for that problem. It was maintained that photothermoelectric effect under certain conditions results in strong response of such devices to terahertz radiation even at room temperature. In this work, we investigate different mechanisms underlying the response of asymmetric carbon nanotube (CNT) based devices to sub-terahertz and terahertz radiation. Our structures are formed with CNT networks instead of individual CNTs so that effects probed are more generic and not caused by peculiarities of an individual nanoscale object. We conclude that the DC voltage response observed in our structures is not only thermal in origin. So called diode-type response caused by asymmetry of the device IV characteristic turns out to be dominant at room temperature. Quantitative analysis provides further routes for the optimization of the device configuration, which may result in appearance of novel terahertz radiation detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrated high-order surface diffraction gratings for diode lasers

High-order surface diffraction gratings acting as a distributed Bragg reflector (DBR) in mesa stripe semiconductor lasers (λ = 1030 nm) have been studied theoretically and experimentally. Higher order interfering radiation modes (IRMs), which propagate off the plane of the waveguide, have been shown to have a crucial effect on the reflection and transmission spectra of the DBR. The decrease in the reflectivity of the DBR in response to the increase in the diffraction efficiency of these modes may reach 80% and more. According to theoretical analysis results, the intensity of the higher order IRMs is determined by the geometry of the DBR groove profile. Experimental data demonstrate that the noncavity modes are responsible for parasitic light leakage losses in the laser cavity. It has been shown that, in the case of nonoptimal geometry of the grating groove profile, the overall external differential quantum efficiency of the parasitic laser emission may exceed 45%, which is more than half of the laser output power. The optimal geometry of the DBR groove profile is trapezoidal, with the smallest possible lower base. Experimental evidence has been presented that this geometry considerably reduces the power of the higher order IRMs and minimises the parasitic light leakage loss. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of output factors for stereotactic radiosurgery beams

Accurate dosimetry of the narrow beam tends to be difficult to perform due to the absence of lateral electronic equilibrium and the steep dose gradient, as well as the finite size of detectors. Thus, although the high dose rate 6 MV beam on the VARIAN Trilogy accelerator is increasingly utilized for stereotactic radiosurgery (SRS) treatment, there is no general agreement in the SRS beam output factor values among the Trilogy user community. Trilogy SRS beams are confined by cone collimators and the available collimator sizes range from 5 and 10 to 30 mm, in every 2 mm increment. A range of the relative output factors are in clinic use. This variation may impair observations of dose response and optimizations of the prescribed dose. It is necessary to investigate an accurate, easily performable, and detector independent method for the narrow beam output factor measurement. In this study, a scanning beam/scanning chamber method was proposed to overcome the limitation/difficulty of using a relatively large detector in narrow beam output factor measurement. Specifically, for the scanning beam method, multiple narrow beams are used for the dose measurement using a finite size chamber. These multiple scanning beams form an equivalent large uniform field which provides lateral electron equilibrium condition. After the measurement, the contributions from neighboring beams are deconvolved and the value is used for output factor determinations. For a Linac that cannot move a beam laterally, the scanning chamber method can be used to achieve the same result. The output factors determined in such a method were compared to chambers (a 0.015 cc PTW PinPoint ion chamber and a 0.125 cc PTW ion chamber) and film measurement, as well as with Monte Carlo simulation. Film and Monte Carlo results are found to be in excellent agreement with the measurement using the scan beam method. However, the VARIAN recommended output factors measured directly by Wellhoefer CC01 chamber and Scanditronix photon field diode are consistently higher for all the cones. Especially for the 5 mm cone, the difference is more than 10%. Overall, the results suggested that the new method can help overcoming the detector volume averaging effect and the positioning uncertainties, which constitute the major challenge in small radiosurgical beam output factor measurement, and provide reliable output factors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final report of Sandia National Laboratories (SNL) contribution to IAEA CRP F11016 on ''Utilization of ion accelerators for studying and modeling of radiation induced defects in semiconductors and insulator''

This is the final report of Sandia National Laboratories’ activities within the International Atomic Energy Agency (IAEA) Collaboration Research Project (CRP) F11016. The goal of this CRP is to study the effects of radiation on semiconductors and insulators with the emphasis on the effect of displacement damage due to MeV energy ions on the performance of semiconductor detectors and microelectronic devices. The devices used in this study were received from the university of Helsinki, but some other commercial diodes from Hamatsu were investigated, too. SNL’s role in the project was to perform irradiation, C-­V and Ion Beam Induced Charge (IBIC) measurements on the devices. In addition we performed Binary Collision Approximation (BCA) calculations to estimate the ionization and damage of the ions used in the experiment by the members of the CRP and created a TCAD model of the irradiation of the devices.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Circuit Controls Turn-On Current

Single choke used in primary circuit with diode arrangement, maintaining dc current flow through choke and setting up a unidirectional magnetic field, limits turn-on current of transformer-rectifier power supply. Technique reduces number and weight of components and minimizes effect of initial inrush surge current on source.

Holmes, K. G.↗

Experimental investigation of the excess charge and time constant of minority carriers in the thin diffused layer of 0.1 Ohm-cm silicon solar cells

The observed low open-circuit voltage in 0.1 Ohm-cm solar cells is probably related to an excessively high diode saturation current. Theoretical studies conducted by Lindholm et al. (1975) and by Godlewski et al. (1975) have shown that a high saturation current could be produced by either high recombination rates or bandgap narrowing effects. A description is given of an investigation which shows that bandgap narrowing effects have a first order significance in determining the charge carrier transport controlling the open-circuit voltage of 0.1 Ohm-cm silicon solar cells.

Godlewski, M. P.↗

Study of Molecular Line Parameters down to Very Low Temperature

The impact of precise spectroscopic measurements on the P(9) multiplet in the v3 band of 12CH4, obtained using a newly developed cold Herriott cell coupled with a tunable diode laser spectrometer, is examined in the context of remote sensing of methane in the atmosphere. More specifically, the influence of the air-broadening temperature dependence, of line narrowing and of line-mixing effects is assessed when fitting high resolution atmospheric spectra recorded from a balloon in the solar occultation mode. This is achieved by considering residuals and retrieved methane volume mixing ratio profiles. By combining data from previous studies together with new measurements, the expression for the temperature dependence of the broadening coefficient has been revisited. It is shown that a correcting factor applied to the usual law gives better results, when considering all the available measurements from room temperature down to about 10-20 K, as compared to the usual expression of the width versus temperature. These results clearly demonstrate that collision broadening is more sensitive to long-range attractive forces when the temperature is decreased.

Mondelain, D.↗

Pd/CeO2/SiC Chemical Sensors

The incorporation of nanostructured interfacial layers of CeO2 has been proposed to enhance the performances of Pd/SiC Schottky diodes used to sense hydrogen and hydrocarbons at high temperatures. If successful, this development could prove beneficial in numerous applications in which there are requirements to sense hydrogen and hydrocarbons at high temperatures: examples include monitoring of exhaust gases from engines and detecting fires. Sensitivity and thermal stability are major considerations affecting the development of high-temperature chemical sensors. In the case of a metal/SiC Schottky diode for a number of metals, the SiC becomes more chemically active in the presence of the thin metal film on the SiC surface at high temperature. This increase in chemical reactivity causes changes in chemical composition and structure of the metal/SiC interface. The practical effect of the changes is to alter the electronic and other properties of the device in such a manner as to degrade its performance as a chemical sensor. To delay or prevent these changes, it is necessary to limit operation to a temperature <450 C for these sensor structures. The present proposal to incorporate interfacial CeO2 films is based partly on the observation that nanostructured materials in general have potentially useful electrical properties, including an ability to enhance the transfer of electrons. In particular, nanostructured CeO2, that is CeO2 with nanosized grains, has shown promise for incorporation into hightemperature electronic devices. Nanostructured CeO2 films can be formed on SiC and have been shown to exhibit high thermal stability on SiC, characterized by the ability to withstand temperatures somewhat greater than 700 C for limited times. The exchanges of oxygen between CeO2 and SiC prevent the formation of carbon and other chemical species that are unfavorable for operation of a SiC-based Schottky diode as a chemical sensor. Consequently, it is anticipated that in a Pd/CeO2/SiC Schottky diode, the nanostructured interfacial CeO2 layer would contribute to thermal stability and, by contributing to transfer of electrons, would also contribute to sensitivity.

Lu, Weijie↗

Source geometric considerations for OMEGA Dante measurements

The Dante is a 15 channel filtered diode array which is installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The system yields the spectrally and temporally resolved radiation flux from 50 eV to 10 keV from various targets (i.e., Hohlraum, gas pipes, etc.). The absolute flux is determined from the radiometric calibration of the x-ray diodes, filters, and mirrors and an unfold algorithm applied to the recorded voltages from each channel. The unfold algorithm assumes an emitting source that is spatially uniform and has a constant area as a function of photon energy. The emitting x-ray source is usually considered to be the laser entrance hole (LEH) of a given diameter for Hohlraum type targets or the effective wall area of high conversion efficiency K-shell type targets. This assumption can be problematic for several reasons. High intensity regions or 'hot spots' in the x-ray are observed where the drive laser beams strike the target. The 'hot spots' create non-uniform emission seen by the Dante. Additionally, thinned walled (50 {mu}m) low-Z targets (C{sub 22}H{sub 10}N{sub 2}O{sub 5}) have an energy dependent source size since the target's walls will be fully opaque for low energies (E < 2-3 keV) yet fully transmissive at higher energies. Determining accurate yields can be challenging for these types of targets. Discussion and some analysis will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗