Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Exploring the Potential of ASHRAE Guideline 36 in District Cooling Systems: Preprint

ASHRAE Guideline 36-2021 (G36) provides high-performance control sequences for all-air and hydronic HVAC systems, and it has proven effective at reducing energy use for single building all-air equipment. The most recent version of G36 included control sequences for water-cooled chiller plants, which can be used in district cooling systems (DCSs). Despite not being a traditional application of G36 controls, DCSs could benefit from energy savings that G36 control sequences have demonstrated in single building systems. We therefore investigate the possibility to extend G36 chiller plant control from a single building to district cooling using a real-world district cooling system in Boulder, Colorado as a case study. Four timeframes representing low to peak loads are simulated and analyzed to compare energy use of the district cooling system for three control sequences. Results show that although G36 chiller plant sequences can be applied to DCSs, further analysis and potentially control optimization is needed to ensure energy savings compared to default controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Tracing the Cosmic Evolution of the Cool Circumgalactic Medium of Luminous Red Galaxies with DESI Year 1 Data

We investigate the properties of the cool circumgalactic medium (CGM) of massive galaxies and their cosmic evolution. By using the year 1 dataset of luminous red galaxies (LRGs) and QSOs from the Dark Energy Spectroscopic Instrument survey, we construct a sample of approximately 600,000 galaxy-quasar pairs and measure the radial distribution and kinematics of the cool gas traced by Mg II absorption lines as a function of galaxy properties from redshift 0.4 to redshift 1.2. Our results show that the covering fraction of the cool gas around LRGs increases with redshift, following a trend similar to the global evolution of galaxy star formation rate. At small radii (< 0.3rvir), the covering fraction anti-correlates with stellar mass, suggesting that mass-dependent processes suppress the cool gas content in the inner region. In addition, we measure the gas dispersion by modeling the velocity distribution of absorbers with a narrow and a broad components -- sigma_n ~ 160 and sigma_b ~ 380 km/s -- and quantify their relative contributions. The results show that the broad component becomes more prominent in the outer region, and its relative importance in the central region grows with increasing stellar mass. Finally, we discuss possible origins of the cool gas around massive galaxies, including the contribution of satellite galaxies and the precipitation scenario.

Chang, Yu-Ling [Taiwan, Natl. Taiwan U.] (ORCID:00↗

Summary of Field Measurement on UF6 Cylinders Using Electro-Mechanically Cooled Systems

Measurement of the enrichment of solid state UF6 stored within large metal cylinders is a task commonly performed by plant operators and inspectors. The measurement technologies typically used range from low-resolution, high-efficiency sodium iodide detectors to high-resolution, moderate-efficiency high-purity germanium (HPGe) detectors. The technology used and methods deployed are dependent upon the material being measured, environmental conditions, time constraints, and measurement-precision requirements. Operators and inspectors typically use specially designed, HPGe detectors that are cooled with liquid nitrogen in situations where high-resolution measurements are required. However, the requirement for periodically refilling the system with liquid nitrogen makes remote usage cumbersome and slow. The task of cooling the detector reduces the available time for the inspector to perform other safeguards activities while on site. If the inspector has to reduce the count time for each selected cylinder to ensure that all preselected cylinders are measured during the inspection, the resulting measurement uncertainties may be increased, making it more difficult to detect and verify potential discrepancies in the operator's declarations. However, recent advances in electromechanically cooled HPGe detectors may provide the inspector with an improved verification tool by eliminating the need for liquid nitrogen. This report provides a summary of test results for field measurements performed using electromechanically cooled HPGe detectors on depleted, natural, and low-enriched uranium cylinders. The results of the study provide valuable information to inspectors and operators regarding the capabilities and limitations of electromechanically cooled systems based on true field-measurement conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Role of small lead-cooled fast reactors for international deployment in worldwide sustainable nuclear energy supply.

Most recently, the global nuclear energy partnership (GNEP) has identified, as one of its key objectives, the development and demonstration of concepts for small and medium-sized reactors (SMRs) that can be globally deployed while assuring a high level of proliferation resistance. Lead-cooled systems offer several key advantages in meeting these goals. The small lead-cooled fast reactor concept known as the small secure transportable autonomous reactor (SSTAR) has been under ongoing development as part of the US advanced nuclear energy systems programs. Meeting future worldwide projected energy demands during this century (e.g., 1000 to 2000 GWe by 2050) in a sustainable manner while maintaining CO2 emissions at or below today's level will require massive deployments of nuclear reactors in non-fuel cycle states as well as fuel cycle states. The projected energy demands of non-fuel cycle states will not be met solely through the deployment of Light Water Reactors (LWRs) in those states without using up the world's resources of fissile material (e.g., known plus speculative virgin uranium resources = 15 million tonnes). The present U.S. policy is focused upon domestic deployment of large-scale LWRs and sodium-cooled fast spectrum Advanced Burner Reactors (ABRs) working in a symbiotic relationship that burns existing fissile material while destroying the actinides which are generated. Other major nuclear nations are carrying out the development and deployment of SFR breeders as witness the planning for SFR breeder deployments in France, Japan, China, India, and Russia. Small (less that 300 MWe) and medium (300 to 700 MWe) size reactors are better suited to the growing economies and infrastructures of many non-fuel cycle states and developing nations. For those deployments, fast reactor converters which are fissile self-sufficient by creating as much fissile material as they consume are preferred to breeders that create more fissile material than they consume. Thus, there is a need for small and medium size fast reactors in non-fuel cycle states operating in a converter mode as well as large sodium-cooled fast breeders in fuel cycle states. Desired attributes for exportable small fast reactors include: proliferation resistance features such as restricted access to fuel; long core life further restricting access by reducing or eliminating the need for refueling; restricted potential to be misused in a breeding mode; fuel form that is unattractive in the safeguards sense; and a conversion ratio of unity to self-generate as much fissile material as is consumed. Desired attributes for exportable small reactor deployments in developing nations and remote sites also include: a small power level to match the smaller demand of towns or sites that are off-grid or on immature local grids; low enough cost to be economically competitive with alternative energy sources available to developing nation customers (e.g. diesel generators in remote locations); readily transported and assembled from transportable modules; simple to operate and highly reliable reducing plant operating staff requirements; as well as high reliability and passive safety reducing the number of accident initiators and need for safety systems as well as reducing the size of the exclusion and emergency planning zones. The Lead-Cooled Fast Reactor (LFR) has the desired attributes. An example of a small exportable LFR concept is the 20 MWe (45 MWt) Small Secure Transportable Autonomous Reactor (SSTAR) incorporating proliferation resistance, fissile selfsufficiency, autonomous load following, a high degree of passive safety, and supercritical carbon dioxide Brayton cycle energy conversion for high plant efficiency and improved economic competitiveness.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydronic rooftop cooling systems

A roof top cooling unit has an evaporative cooling section that includes at least one evaporative module that pre-cools ventilation air and water; a condenser; a water reservoir and pump that captures and re-circulates water within the evaporative modules; a fan that exhausts air from the building and the evaporative modules and systems that refill and drain the water reservoir. The cooling unit also has a refrigerant section that includes a compressor, an expansion device, evaporator and condenser heat exchangers, and connecting refrigerant piping. Supply air components include a blower, an air filter, a cooling and/or heating coil to condition air for supply to the building, and optional dampers that, in designs that supply less than 100% outdoor air to the building, control the mixture of return and ventilation air.

42 ENGINEERING↗

Effect of occupant behavior on peak cooling and dehumidification loads in typical and high-efficiency homes

Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure, installing the ductwork in conditioned space, and improving the building's airtightness results in significant reductions in externally-driven sensible and latent cooling loads. As a building's efficiency is improved, occupant-related internal gains become a larger portion of the building sensible and latent loads. Additionally, internal gains are highly uncertain compared to other load components. In this study, we use a stochastic approach to simulate occupant-related internal gains and compare the internal gains to other sensible and latent heat sources in four house efficiency levels in 10 U.S. climates using whole-building energy simulation software. We compare the expected range in occupant-related internal gains to other building characteristics such as cooling set point, air infiltration rate, and mechanical ventilation rate. We show that in high-efficiency homes, sensible internal gains vary from less than 10% to greater than 40% of the building sensible load under peak total cooling conditions depending on climate and internal gain profile. Likewise, latent internal gains vary from less than 10% to more than 60% of the building latent load under peak total cooling and peak dehumidification conditions depending on climate and internal gain profile.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New correlation to predict the heat transfer coefficient in-tube cooling of supercritical CO{sub 2} in horizontal macro-tubes

The heat transfer coefficient during gas cooling process of supercritical CO{sub 2} without lubricating oil in horizontal macro-tubes has experimentally investigated. Investigation has done on two stainless steel circular tubes having inside-diameter of 4.55 mm and 7.75 mm and carried out for CO{sub 2} mass fluxes of 200-600 kg/m{sup 2} s, inlet fluid pressures of 7.5-10.0 MPa, and the inlet fluid temperatures of 90-100 C. The experimental results indicate that the gas cooling pressure, the inner tube diameter, the mass flux and the temperature of CO{sub 2} have significant effects on the heat transfer coefficient, especially near pseudo-critical region. The heat transfer coefficient decreases as the cooling pressure increases otherwise increases as mass flux increases. At any temperatures, smaller inner tube diameter shows higher heat transfer coefficient. In comparison between present experimental data and existing correlations from references, most of supercritical heat transfer correlations show large deviations with this present experimental data. Therefore, based on experimental data obtained in this present work, a new correlation is proposed to predict more accurate heat transfer coefficient of supercritical CO{sub 2} in horizontal macro-tubes under cooling conditions. The majority of the experimental values are within 13% of the values predicted by the new correlation. (author)

42 ENGINEERING↗

Utilization of municipal wastewater for cooling in thermoelectric power plants

A process simulation model has been developed using Aspen Plus® with the OLI (OLI System, Inc.) water chemistry model to predict water quality in the recirculating cooling loop utilizing secondary- and tertiary-treated municipal wastewater as the source of makeup water. Simulation results were compared with pilot-scale experimental data on makeup water alkalinity, loop pH, and ammonia evaporation. The effects of various parameters including makeup water quality, salt formation, NH 3 and CO 2 evaporation mass transfer coefficients, heat load, and operating temperatures were investigated. The results indicate that, although the simulation model can capture the general trends in the loop pH, experimental data on the rates of salt precipitation in the system are needed for more accurate prediction of the loop pH. It was also found that stripping of ammonia and carbon dioxide in the cooling tower can influence the cooling loop pH significantly. The effects of the NH 3 mass transfer coefficient on cooling loop pH appear to be more significant at lower values (e.g., k NH3 < 4×10 -3 m/s) when the makeup water alkalinity is low (e.g., <90 mg/L as CaCO 3 ). The effect of the CO2 mass transfer coefficient was found to be significant only at lower alkalinity values (e.g., k CO2 <4×10 -6 m/s).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental evaluation of thermal-fluids performance of Helium-Cooled Flat Plate (HCFP) divertor

Various helium (He)-cooled solid-tungsten (W) divertor concepts have been proposed for long-pulse magnetic fusion energy reactors. Among these concepts, the He-cooled flat plate divertor (HCFP) modules have the largest plasma-facing surface area of ~0.2 m 2 . Simulations have shown that the most recent version of the design can withstand heat fluxes as great as 8 MW/m 2 . Earlier experimental studies of a single shortened HCFP cooling unit with a slot length of 7.6 cm used air at ambient temperature and pressures below 0.6 MPa. Here, we present initial experimental studies of a copper alloy and steel test section modeling a shortened HCFP cooling unit using He at prototypical pressure of 10 MPa, inlet temperatures T i ≤ 200 °C and steady-state incident heat fluxes q" ≤ 1.2 MW/m 2 . Results for Nusselt number Nu as a function of Reynolds number Re were obtained for Re = 1.2×10 4 –3.4×10 4 , and used to develop a Nu(Re) correlation and validate numerical models of the test section using commercial computational fluid dynamics (CFD) software. Simulations with this model are performed to evaluate the effect of the shortened slot. Furthermore, these analyses are used to estimate the thermal-fluids performance of the HCFP under prototypical conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy and economic assessment of desiccant cooling systems coupled with single glazed air and hybrid PV/thermal solar collectors for applications in hot and humid climate

This paper presents a detailed analysis of the energy and economic performance of desiccant cooling systems (DEC) equipped with both single glazed standard air and hybrid photovoltaic/thermal (PV/t) collectors for applications in hot and humid climates. The use of 'solar cogeneration' by means of PV/t hybrid collectors enables the simultaneous production of electricity and heat, which can be directly used by desiccant air handling units, thereby making it possible to achieve very energy savings. The present work shows the results of detailed simulations conducted for a set of desiccant cooling systems operating without any heat storage. System performance was investigated through hourly simulations for different systems and load combinations. Three configurations of DEC systems were considered: standard DEC, DEC with an integrated heat pump and DEC with an enthalpy wheel. Two kinds of building occupations were considered: office and lecture room. Moreover, three configurations of solar-assisted air handling units (AHU) equipped with desiccant wheels were considered and compared with standard AHUs, focusing on achievable primary energy savings. The relationship between the solar collector's area and the specific primary energy consumption for different system configurations and building occupation patterns is described. For both occupation patterns, sensitivity analysis on system performance was performed for different solar collector areas. Also, this work presents an economic assessment of the systems. The cost of conserved energy and the payback time were calculated, with and without public incentives for solar cooling systems. It is worth noting that the use of photovoltaics, and thus the exploitation of related available incentives in many European countries, could positively influence the spread of solar air cooling technologies (SAC). An outcome of this work is that SAC systems equipped with PV/t collectors are shown to have better performance in terms of primary energy saving than conventional systems fed by vapour compression chillers and coupled with PV cells. All SAC systems present good figures for primary energy consumption. The best performances are seen in systems with integrated heat pumps and small solar collector areas. The economics of these SAC systems at current equipment costs and energy prices are acceptable. They become more interesting in the case of public incentives of up to 30% of the investment cost (Simple Payback Time from 5 to 10 years) and doubled energy prices. (author)

14 SOLAR ENERGY↗

Solar absorption cooling plant in Seville

A solar/gas cooling plant at the Engineering School of Seville (Spain) was tested during the period 2008-2009. The system is composed of a double-effect LiBr + water absorption chiller of 174 kW nominal cooling capacity, powered by: (1) a pressurized hot water flow delivered by mean of a 352 m{sup 2} solar field of a linear concentrating Fresnel collector and (2) a direct-fired natural gas burner. The objective of the project is to indentify design improvements for future plants and to serve as a guideline. We focused our attention on the solar collector size and dirtiness, climatology, piping heat losses, operation control and coupling between solar collector and chiller. The daily average Fresnel collector efficiency was 0.35 with a maximum of 0.4. The absorption chiller operated with a daily average coefficient of performance of 1.1-1.25, where the solar energy represented the 75% of generator's total heat input, and the solar cooling ratio (quotient between useful cooling and insolation incident on the solar field) was 0.44. (author)

14 SOLAR ENERGY↗

Magnetic reconnection with radiative cooling. I. Optically thin regime

Magnetic reconnection processes in many high-energy-density astrophysical and laboratory plasma systems are significantly affected by radiation; hence traditional, nonradiative reconnection models are not applicable to these systems. Motivated by this observation, the present paper develops a Sweet-Parker-like theory of resistive magnetic reconnection with strong radiative cooling. It is found that, in the case with zero guide field, intense radiative cooling leads to a strong plasma compression, resulting in a higher reconnection rate. The compression ratio and the reconnection layer temperature are determined by the balance between ohmic heating and radiative cooling. The lower temperature in a radiatively cooled layer leads to a higher Spitzer resistivity and, hence, a higher reconnection rate. Several specific radiative processes (bremsstrahlung, cyclotron, and inverse Compton) in the optically thin regime are considered for both the zero- and strong-guide-field cases, and concrete expressions for the reconnection parameters are derived, along with the applicability conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress of a room temperature electron cyclotron resonance ion source using evaporative cooling technology at Institute of Modern Physics

A new room temperature ECR ion source, Lanzhou Electron Cyclotron Resonance ion source No. 4 (LECR4, previously named DRAGON), is under intense construction at Institute of Modern Physics. LECR4 is designed to operate with 18 GHz microwave frequency. The maximum axial magnetic fields are 2.3 T at injection and 1.3 T at extraction, and the radial field at the plasma chamber wall of 76 mm inner diameter is 1.0–1.2 T. One of the unique features for LECR4 is that its axial solenoids are winded with solid square copper wires which are immersed in a kind of special evaporative cooling medium for cooling purpose. Till now, a prototype of the cooling system has been successfully constructed and tested, which has demonstrated that the cooling efficiency of the designed system could meet the requirements of LECR4 under the routine operation conditions. All the main components of the ion source have been completed. Assembly and commissioning is ongoing. The latest developments and test results will be presented in this paper.

43 PARTICLE ACCELERATORS↗

THE TAIL OF THE STRIPPED GAS THAT COOLED: H I, Halpha, AND X-RAY OBSERVATIONAL SIGNATURES OF RAM PRESSURE STRIPPING

Galaxies moving through the intracluster medium (ICM) of a cluster of galaxies can lose gas via ram pressure stripping. This stripped gas forms a tail behind the galaxy which is potentially observable. In this paper, we carry out hydrodynamical simulations of a galaxy undergoing stripping with a focus on the gas properties in the wake and their observational signatures. We include radiative cooling in an adaptive hydrocode in order to investigate the impact of a clumpy, multi-phase interstellar medium. We find that including cooling results in a very different morphology for the gas in the tail, with a much wider range of temperatures and densities. The tail is significantly narrower in runs with radiative cooling, in agreement with observed wakes. In addition, we make detailed predictions of H I, Halpha, and X-ray emission for the wake, showing that we generally expect detectable H I and Halpha signatures, but no observable X-ray emission (at least for our chosen ram pressure strength and ICM conditions). We find that the relative strength of the Halpha diagnostic depends somewhat on our adopted minimum temperature floor (below which we set cooling to zero to mimic physics processes not included in the simulation).

79 ASTRONOMY AND ASTROPHYSICS↗

COOLING TIME, FREEFALL TIME, AND PRECIPITATION IN THE CORES OF ACCEPT GALAXY CLUSTERS

Star formation in the universe's largest galaxies—the ones at the centers of galaxy clusters—depends critically on the thermodynamic state of their hot gaseous atmospheres. Central galaxies with low-entropy, high-density atmospheres frequently contain multiphase star-forming gas, while those with high-entropy, low-density atmospheres never do. The dividing line between these two populations in central entropy, and therefore central cooling time, is amazingly sharp. Two hypotheses have been proposed to explain the dichotomy. One points out that thermal conduction can prevent radiative cooling of cluster cores above the dividing line. The other holds that cores below the dividing line are subject to thermal instability that fuels the central active galactic nucleus (AGN) through a cold-feedback mechanism. Here we explore those hypotheses with an analysis of the Hα properties of ACCEPT galaxy clusters. We find that the two hypotheses are likely to be complementary. Our results support a picture in which cold clouds inevitably precipitate out of cluster cores in which cooling outcompetes thermal conduction and rain down on the central black hole, causing AGN feedback that stabilizes the cluster core. In particular, the observed distribution of the cooling-time to freefall-time ratio is nearly identical to that seen in simulations of this cold-feedback process, implying that cold-phase accretion, and not Bondi-like accretion of hot-phase gas, is responsible for the AGN feedback that regulates star formation in large galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Pebble Fuel Handling and Reactivity Control for Salt-Cooled High Temperature Reactors

This report documents the work completed on the X-PREX facility under NEUP Project 11- 3172. This project seeks to demonstrate the viability of pebble fuel handling and reactivity control for fluoride salt-cooled high-temperature reactors (FHRs). The research results also improve the understanding of pebble motion in helium-cooled reactors, as well as the general, fundamental understanding of low-velocity granular flows. Successful use of pebble fuels in with salt coolants would bring major benefits for high-temperature reactor technology. Pebble fuels enable on-line refueling and operation with low excess reactivity, and thus simpler reactivity control and improved fuel utilization. If fixed fuel designs are used, the power density of salt- cooled reactors is limited to 10 MW/m 3 to obtain adequate duration between refueling, but pebble fuels allow power densities in the range of 20 to 30 MW/m 3 . This can be compared to the typical modular helium reactor power density of 5 MW/m3. Pebble fuels also permit radial zoning in annular cores and use of thorium or graphite pebble blankets to reduce neutron fluences to outer radial reflectors and increase total power production. Combined with high power conversion efficiency, compact low-pressure primary and containment systems, and unique safety characteristics including very large thermal margins (>500°C) to fuel damage during transients and accidents, salt-cooled pebble fuel cores offer the potential to meet the major goals of the Advanced Reactor Concepts Development program to provide electricity at lower cost than light water reactors with improved safety and system performance.This report presents the facility description, experimental results, and supporting simulation methods of the new X-Ray Pebble Recirculation Experiment (X-PREX), which is now operational and being used to collect data on the behavior of slow dense granular flows relevant to pebble bed reactor core designs. The X-PREX facility uses novel digital x-ray tomography methods to track both the translational and rotational motion of spherical pebbles, which provides unique experimental results that can be used to validate discrete element method (DEM) simulations of pebble motion. The validation effort supported by the X-PREX facility provides a means to build confidence in analysis of pebble bed configuration and residence time distributions that impact the neutronics, thermal hydraulics, and safety analysis of pebble bed reactor cores. Experimental and DEM simulation results are reported for silo drainage, a classical problem in the granular flow literature, at several hopper angles. These studies include conventional converging and novel diverging geometries that provide additional flexibility in the design of pebble bed reactor cores. Excellent agreement is found between the X-PREX experimental and DEM simulation results. This report also includes results for additional studies relevant to the design and analysis of pebble bed reactor cores including the study of forces on shut down blades inserted directly into a packed bed and pebble flow in a cylindrical hopper that is representative of a small test reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reducing Residential Peak Electricity Demand with Mechanical Pre-Cooling of Building Thermal Mass

This study uses an advanced airflow, energy and humidity modelling tool to evaluate the potential for residential mechanical pre-cooling of building thermal mass to shift electricity loads away from the peak electricity demand period. The focus of this study is residential buildings with low thermal mass, such as timber-frame houses typical to the US. Simulations were performed for homes in 12 US DOE climate zones. The results show that the effectiveness of mechanical pre-cooling is highly dependent on climate zone and the selected pre-cooling strategy. The expected energy trade-off between cooling peak energy savings and increased off-peak energy use is also shown.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗