Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

SECOND SEASON QUIET OBSERVATIONS: MEASUREMENTS OF THE COSMIC MICROWAVE BACKGROUND POLARIZATION POWER SPECTRUM AT 95 GHz

The Q/U Imaging ExperimenT (QUIET) has observed the cosmic microwave background (CMB) at 43 and 95 GHz. The 43 GHz results have been published in a previous paper, and here we report the measurement of CMB polarization power spectra using the 95 GHz data. This data set comprises 5337 hr of observations recorded by an array of 84 polarized coherent receivers with a total array sensitivity of 87 {mu}K{radical}s. Four low-foreground fields were observed, covering a total of {approx}1000 deg{sup 2} with an effective angular resolution of 12.'8, allowing for constraints on primordial gravitational waves and high signal-to-noise measurements of the E-modes across three acoustic peaks. The data reduction was performed using two independent analysis pipelines, one based on a pseudo-C {sub l} (PCL) cross-correlation approach, and the other on a maximum-likelihood (ML) approach. All data selection criteria and filters were modified until a predefined set of null tests had been satisfied before inspecting any non-null power spectrum. The results derived by the two pipelines are in good agreement. We characterize the EE, EB, and BB power spectra between l = 25 and 975 and find that the EE spectrum is consistent with {Lambda}CDM, while the BB power spectrum is consistent with zero. Based on these measurements, we constrain the tensor-to-scalar ratio to r = 1.1{sup +0.9} {sub -0.8} (r < 2.8 at 95% C.L.) as derived by the ML pipeline, and r = 1.2{sup +0.9} {sub -0.8} (r < 2.7 at 95% C.L.) as derived by the PCL pipeline. In one of the fields, we find a correlation with the dust component of the Planck Sky Model, though the corresponding excess power is small compared to statistical errors. Finally, we derive limits on all known systematic errors, and demonstrate that these correspond to a tensor-to-scalar ratio smaller than r = 0.01, the lowest level yet reported in the literature.

79 ASTRONOMY AND ASTROPHYSICS↗

The Mu2e undoped CsI crystal calorimeter

We present the Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Lastly, although the readout electronics were not final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Graph neural network for neutrino physics event reconstruction

Liquid argon time projection chamber (LArTPC) detector technology offers a wealth of high-resolution information on particle interactions, and leveraging that information to its full potential requires sophisticated automated reconstruction techniques. Here, this article describes NUGRAPH 2, a graph neural network for low-level reconstruction of simulated neutrino interactions in a LArTPC detector. Simulated neutrino interactions in the MicroBooNE detector geometry are described as heterogeneous graphs, with energy depositions on each detector plane forming nodes on planar subgraphs. The network utilizes a multihead attention message-passing mechanism to perform background filtering and semantic labeling on these graph nodes, identifying those associated with the primary physics interaction with 98.0% efficiency and labeling them according to particle type with 94.9% efficiency. The network operates directly on detector observables across multiple two-dimensional representations but utilizes a three-dimensional-context-aware mechanism to encourage consistency between these representations. Model inference takes 0.12 s / event on a CPU and 0.005 s / event batched on a GPU. This architecture is designed to be a general-purpose solution for particle reconstruction in neutrino physics, with the potential for deployment across a broad range of detector technologies, and offers a core convolution engine that can be leveraged for a variety of tasks beyond the two described in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Knowledge Network-Based Approach to Facilitate Annotation of Clinical Pathway Component Clusters

Mining electronic health records (EHRs) to identify contextually related clinical concept clusters that tend to co-occur temporarily and consistently could improve data-driven clinical pathway (CP) construction. However, the automatic extraction of contextually related clinical concept clusters contains a vast amount of irrelevant information. Hence, this paper proposes a knowledge network-enabled literature-based discovery (LBD) approach to remove noise from clusters. The authors used published literature to filter spurious concepts from the clusters and used data from the US Department of Veterans Affairs’s major depressive disorder (MDD) cohort of Operation Enduring Freedom/Operation Iraqi Freedom (OEF/OIF) for their experimentation. The approach was applied to 2,967 clusters extracted from the MDD OEF/OIF database. The experimental results demonstrate that the proposed approach can filter 94% of the irrelevant information. Moreover, the authors applied various network mining algorithms to analyze the clusters and demonstrated that LBD, along with network mining techniques, is a useful method for finding accurate contextually related clinical concept clusters. This could help domain researchers perform advanced analytics in CPs.

Hasan, S M Shamimul↗

Modal methods in optimal control synthesis

Efficient algorithms for solving linear smoother-follower problems with quadratic criteria are presented. For time-invariant systems, the algorithm consists of one backward integration of a linear vector equation and one forward integration of another linear vector equation. Furthermore, the backward and forward Riccati matrices can be expressed in terms of the eigenvalues and eigenvectors of the Euler-Lagrange equations. Hence, the gains of the forward and backward Kalman-Bucy filters and of the optimal state-feedback regulator can be determined without integration of matrix Riccati equations. A computer program has been developed, based on this method of determining the gains, to synthesize the optimal time-invariant compensator in the presence of random disturbance inputs and random measurement errors. The program also computes the rms state and control variables of the optimal closed-loop system.

Bryson, A. E., Jr.↗

Compact Radiative Control Structures for Millimeter Astronomy

We have designed, fabricated, and tested compact radiative control structures, including antireflection coatings and resonant absorbers, for millimeter through submillimeter wave astronomy. The antireflection coatings consist of micromachined single crystal silicon dielectric sub-wavelength honeycombs. The effective dielectric constant of the structures is set by the honeycomb cell geometry. The resonant absorbers consist of pieces of solid single crystal silicon substrate and thin phosphorus implanted regions whose sheet resistance is tailored to maximize absorption by the structure. We present an implantation model that can be used to predict the ion energy and dose required for obtaining a target implant layer sheet resistance. A neutral density filter, a hybrid of a silicon dielectric honeycomb with an implanted region, has also been fabricated with this basic approach. These radiative control structures are scalable and compatible for use large focal plane detector arrays.

Brown, Ari D.↗

Accelerated Aging in Electrolytic Capacitors for Prognostics

The focus of this work is the analysis of different degradation phenomena based on thermal overstress and electrical overstress accelerated aging systems and the use of accelerated aging techniques for prognostics algorithm development. Results on thermal overstress and electrical overstress experiments are presented. In addition, preliminary results toward the development of physics-based degradation models are presented focusing on the electrolyte evaporation failure mechanism. An empirical degradation model based on percentage capacitance loss under electrical overstress is presented and used in: (i) a Bayesian-based implementation of model-based prognostics using a discrete Kalman filter for health state estimation, and (ii) a dynamic system representation of the degradation model for forecasting and remaining useful life (RUL) estimation. A leave-one-out validation methodology is used to assess the validity of the methodology under the small sample size constrain. The results observed on the RUL estimation are consistent through the validation tests comparing relative accuracy and prediction error. It has been observed that the inaccuracy of the model to represent the change in degradation behavior observed at the end of the test data is consistent throughout the validation tests, indicating the need of a more detailed degradation model or the use of an algorithm that could estimate model parameters on-line. Based on the observed degradation process under different stress intensity with rest periods, the need for more sophisticated degradation models is further supported. The current degradation model does not represent the capacitance recovery over rest periods following an accelerated aging stress period.

Celaya, Jose R.↗

Observing Tsunamis in the Ionosphere Using Ground Based GPS Measurements

Ground-based Global Positioning System (GPS) measurements of ionospheric Total Electron Content (TEC) show variations consistent with atmospheric internal gravity waves caused by ocean tsunamis following recent seismic events, including the Tohoku tsunami of March 11, 2011. We observe fluctuations correlated in time, space, and wave properties with this tsunami in TEC estimates processed using JPL's Global Ionospheric Mapping Software. These TEC estimates were band-pass filtered to remove ionospheric TEC variations with periods outside the typical range of internal gravity waves caused by tsunamis. Observable variations in TEC appear correlated with the Tohoku tsunami near the epicenter, at Hawaii, and near the west coast of North America. Disturbance magnitudes are 1-10% of the background TEC value. Observations near the epicenter are compared to estimates of expected tsunami-driven TEC variations produced by Embry Riddle Aeronautical University's Spectral Full Wave Model, an atmosphere-ionosphere coupling model, and found to be in good agreement. The potential exists to apply these detection techniques to real-time GPS TEC data, providing estimates of tsunami speed and amplitude that may be useful for future early warning systems.

total electron content (TEC)↗

Virtual Microscope Views of the Apollo 11 and 12 Lunar Samples

The Apollo virtual microscope is a means of viewing, over the Internet, polished thin sections of every rock in the Apollo lunar sample collections via software, duplicating many of the functions of a petrological microscope, is described. Images from the Apollo 11 and 12 missions may be viewed at: www.virtualmicroscope.org/content/apollo. Introduction: During the six NASA missions to the Moon from 1969-72 a total of 382 kilograms of rocks and soils, often referred to as "the legacy of Apollo", were collected and returned to Earth. A unique collection of polished thin sections (PTSs) was made from over 400 rocks by the Lunar Sample Curatorial Facility at the Johnson Spacecraft Center (JSC), Houston. These materials have been available for loan to approved PIs but of course they can't be simultaneously investigated by several researchers unless they are co-located or the sample is passed back and forward between them by mail/hand carrying which is inefficient and very risky for irreplaceable material. When The Open University (OU), the world's largest Distance Learning Higher Education Establishment found itself facing a comparable problem (how to supply thousands of undergraduate students with an interactive petrological microscope and a personal set of thin sections), it decided to develop a software tool called the Virtual Microscope (VM). As a result it is now able to make the unique and precious collection of Apollo specimens universally available as a resource for concurrent study by anybody in the world's Earth and Planetary Sciences community. Herein, we describe the first steps of a collaborative project between OU and the Johnson Space Center (JSC) Curatorial Facility to record a PTS for every lunar rock, beginning with those collected by the Apollo 11 and 12 missions. Method: Production of a virtual microscope dedicated to a particular theme divides into four main parts - photography, image processing, building and assembly of virtual microscope components, and publication on a website. Two large research quality microscopes are used to collect all the images required for a virtual microscope. The first is part of an integrated package that utilizes Leica PowerMosaic software and a motorised XYZ stage to generate large area mosaics. It includes a fast acquisition camera and depending on the PTS size normally is used to produce seamless mosaic images consisting of 100-500 individual photographs. If the sample is suitable, three mosaics of each sample are recorded - plane polarised light, between crossed polars and reflected light. In order for the VM to be a true petrological microscope it is necessary to recreate the features of a rotating stage and perform observations using filters to produce polarised light. Thus the petrological VM includes the capability of seeing changes in optical properties (pleochroism and birefringence) during rotation allowing mineral identification. The second microscope in the system provides the functions of the rotating stage. To this microscope we have added a robotically controlled motor to acquire seventy-two images (5 degree intervals) in plane polarised light and between crossed polars. To process the images acquired from the two microscopes involves a combination of proprietary software (Photoshop) and our own in-house code. The final stage involves assembling all the components in an HTML5 environment. Pathfinder investigations: We have undertaken a number of pilot studies to demonstrate the efficacy of the petrological microscope with lunar samples. The first was to make available on-line images collected from the Educational Package of Apollo samples provided by NASA to the UK STFC (Science and Technical Facilities Council) for loan as educational material e.g. for schools. The real PTSs of the samples are now no longer sent out to schools removing the risks associated with transport, accidental breakage and eliminating the possibility of loss. The availability of lunar sample VM-related material was further extended to include twenty-eight specimens from all of the Apollo missions. Some of these samples were made more generally available through an ibook entitled "Moon Rocks: an introduction to the Geology of the Moon," free from the Apple Bookstore. Research possibilities: Although the Virtual Microscope was originally conceived as a teaching aid and was later recognised as a means of public outreach and engagement, we now realize that it also has enormous potential as a high level research tool. Following discussions with the JSC Curators we have received Curation and Analysis Planning Team for Extraterrestrial Materials (CAPTEM) permission to embark on a programme of digitizing the entire lunar sample PTS collection for all three of the above purposes. By the time of the 47th Lunar and Planetary Science Conference (LPSC) we will have completed 81 rocks collected during the Apollo 11 and 12 missions and the data, with cross-links to the Lunar Sample Compendium will go live on the Web at the 47th LPSC. The VM images of the Apollo 11 (41 VM images) and 12 (40 VM images) missions can be viewed at: http:/www.virtualmicroscope.org/content/apollo. The lunar sample VM will enable large numbers of skilled/unskilled microscopists (professional and amateur researchers, educators and students, enthusiasts and the simply curious non-scientists) to share the information from a single sample. It will mean that all the PTSs already cut, even historical ones, could be available for new joint investigations or private study. The scientific return from the collection will increase exponentially as a result of further debate and discussion. Simultaneously the VM will remove the need for making unnecessary multiple samplings, avoid consignment of delicate/breakable specimens (all of which are priceless) to insecure mail/courier services and reduce direct labour and indirect costs, travel budgets and unproductive travelling time necessary for co-location of collaborating researchers. For the future we have already recognized further potential for virtual technology. There is nothing that a petrologist likes more than to see the original rock as a hand specimen. It is entirely possible to recreate virtual hand specimens with 3-D hard and software, already developed for viewing fossils, located within the Curatorial Facility, http://curator.jsc.nasa.gov/lunar/lsc/index.cfm.

Gibson, E. K.↗

Variation in Global Chemical Composition of PM2.5: Emerging Results from SPARTAN

The Surface PARTiculate mAtter Network (SPARTAN) is a long-term project that includes characterization of chemical and physical attributes of aerosols from filter samples collected worldwide. This paper discusses the ongoing efforts of SPARTAN to define and quantify major ions and trace metals found in fine particulate matter (PM (sub 2.5). Our methods infer the spatial and temporal variability of PM (sub 2.5) in a cost-effective manner. Gravimetrically weighed filters represent multi-day averages of PM (sub 2.5), with a collocated nephelometer sampling air continuously. SPARTAN instruments are paired with AErosol RObotic NETwork (AERONET) sun photometers to better understand the relationship between ground-level PM (sub 2.5) and columnar aerosol optical depth (AOD). We have examined the chemical composition of PM (sub 2.5) at 12 globally dispersed, densely populated urban locations and a site at Mammoth Cave (US) National Park used as a background comparison. So far, each SPARTAN location has been active between the years 2013 and 2016 over periods of 2-26 months, with an average period of 12 months per site. These sites have collectively gathered over 10 years of quality aerosol data. The major PM (sub 2.5) constituents across all sites (relative contribution plus or minus Standard Deviation) are ammoniated sulfate (20 percent plus or minus 11 percent), crustal material (13.4 percent plus or minus 9.9 percent), equivalent black carbon (11.9 percent plus or minus 8.4 percent), ammonium nitrate (4.7 percent plus or minus 3.0 percent), sea salt (2.3 percent plus or minus 1.6 percent), trace element oxides (1.0 percent plus or minus 1.1 percent), water (7.2 percent plus or minus 3.3 percent) at 35 percent relative humidity, and residual matter (40 percent plus or minus 24 percent). Analysis of filter samples reveals that several PM (sub 2.5) chemical components varied by more than an order of magnitude between sites. Ammoniated sulfate ranges from 1.1 microns per cubic meter (Buenos Aires, Argentina) to 17 microns per cubic meter (Kanpur, India in the dry season). Ammonium nitrate ranged from 0.2 microns per cubic meter (Mammoth Cave, in summer) to 6.8 microns per cubic meter (Kanpur, dry season). Equivalent black carbon ranged from 0.7 microns per cubic meter (Mammoth Cave) to over 8 microns per cubic meter (Dhaka, Bangladesh and Kanpur, India). Comparison of SPARTAN vs. coincident measurements from the Interagency Monitoring of Protected Visual Environments (IMPROVE) network at Mammoth Cave yielded a high degree of consistency for daily PM (sub 2.5) (r squared equals 0.76, slope equals 1.12), daily sulfate (r squared equals 0.86, slope equals 1.03), and mean fractions of all major PM (sub 2.5) components (within 6 percent). Major ions generally agree well with previous studies at the same urban locations (e.g. sulfate fractions agree within 4 percent for 8 out of 11 collocation comparisons). Enhanced anthropogenic dust fractions in large urban areas (e.g. Singapore, Kanpur, Hanoi, and Dhaka) are apparent from high Zn to Al ratios. The expected water contribution to aerosols is calculated via the hygroscopicity parameter kappa (sub v (volume)) for each filter. Mean aggregate values ranged from 0.15 (Ilorin) to 0.28 (Rehovot). The all-site parameter mean is 0.20 plus or minus 0.04. Chemical composition and water retention in each filter measurement allows inference of hourly PM (sub 2.5) at 35 percent relative humidity by merging with nephelometer measurements. These hourly PM (sub 2.5) estimates compare favourably with a beta attenuation monitor (MetOne) at the nearby US embassy in Beijing, with a coefficient of variation r squared equals 0.67 (number equals 3167), compared to r squared equals 0.62 when v (volume) was not considered. SPARTAN continues to provide an open-access database of PM (sub 2.5) compositional filter information and hourly mass collected from a global federation of instruments.

Snider, Graydon↗

Application of Noise Cancelling and Damage Detection Algorithms in NDE of Concrete Bridge Decks Using Impact Signals

Delamination is a commonly observed distress in concrete bridge decks. Among all the delamination detection methods, acoustic methods have the advantages of being fast and inexpensive. In traditional acoustic inspection methods, the inspector drags a chain along or hammers on the bridge deck and detects delamination from the 'hollowness' of the sounds. The signals are often contaminated by ambient traffic noise and the detection of delamination is highly subjective. This paper describes the performance of an impact-bases acoustic NDE method where the traffic noise was filtered by employing a noise cancelling algorithm and where subjectivity was eliminated by introducing feature extraction and pattern recognition algorithms. Different algorithms were compared and the best one was selected in each category. The comparison showed that the modified independent component analysis (ICA) algorithm was most effective in cancelling the traffic noise and features consisting of mel-frequency cepstral coefficients (MFCCs) had the best performance in terms of repeatability and separabillty. The condition of the bridge deck was then detected by a radial basis function (RBF) neural network. The performance of the system was evaluated using both experimental and field data. The results show that the selected algorithms increase the noise robustness of acoustic methods and perform satisfactorily if the training data is representative.

42 ENGINEERING↗

Data Set Analysis to Reduce Uncertainty in Formula Assignments of Ultrahigh Resolution Mass Spectra

Environmental samples contain a vast array of organic compounds with diverse elemental compositions and heteroatom content. Molecular formula assignments of ultrahigh resolution mass spectra (HRMS) hold promise for elucidating the molecular composition of these compounds. However, the need to account for an assortment of heteroatoms increases the uncertainty associated with individual assignments – and ultimately the ecological, biological, and biogeochemical insights gleaned from the assignments. To address this challenge, we introduce a formula assignment strategy that leverages HRMS data sets to improve assignment confidence, filter false assignments, and mitigate bias in assignment routines. The strategy, implemented using CoreMS, first identifies the highest confidence assignment for a recurring ion in a data set by assessing the mass accuracy and isotopologue similarity of all assignments to the ion across the data set. The second component of the strategy examines the consistency of mass errors for an assigned ion throughout a data set and flags formulas with statistically unlikely deviations in mass error. Here, we illustrate the application and utility of the strategy by comparing its results against documented misassignment patterns within a set of oceanographic samples that were measured with 21 T Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Because the efficacy of our strategy improves with data set size, it is particularly useful for enhancing assignment confidence in large HRMS data sets common in studies of environmental systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of multichannel analyzer using sound card ADC for nuclear spectroscopy system

This paper describes the development of Multi-Channel Analyzer (MCA) using sound card analogue to digital converter (ADC) for nuclear spectroscopy system. The system was divided into a hardware module and a software module. Hardware module consist of detector NaI (Tl) 2” by 2”, Pulse Shaping Amplifier (PSA) and a build in ADC chip from readily available in any computers’ sound system. The software module is divided into two parts which are a pre-processing of raw digital input and the development of the MCA software. Band-pass filter and baseline stabilization and correction were implemented for the pre-processing. For the MCA development, the pulse height analysis method was used to process the signal before displaying it using histogram technique. The development and tested result for using the sound card as an MCA are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high performance neutron powder diffractometer at 3 MW Triga Mark-II research reactor in Bangladesh

A high performance neutron diffractometer called Savar Neutron Diffractometer (SAND) was built and installed at radial beam port-2 of TRIGA Mark II research reactor at AERE, Savar, Dhaka, Bangladesh. Structural studies of materials are being done by this technique to characterize materials crystallograpohically and magnetically. The micro-structural information obtainable by neutron scattering method is very essential for determining its technological applications. This technique is unique for understanding the magnetic behavior in magnetic materials. Ceramic, steel, electronic and electric industries can be benefited from this facility for improving their products and fabrication process. This instrument consists of a Popovicimonochromator with a large linear position sensitive detector array. The monochromator consists of nine blades of perfect single crystal of silicon with 6 mm thickness each. The monochromator design was optimized to provide maximum flux on 3 mm diameter cylindrical sample with a relatively flat angular dependence of resolution. Five different wave lengths can be selected by orienting the crystal at various angles. A sapphire filter was used before the primary collimator to minimize the first neutron. The detector assembly is composed of 15 linear position sensitive proportional counters placed at either 1.1 m or 1.6 m from the sample position and enclosed in a air pad supported high density polythene shield. Position sensing is obtained by charge division using 1-wide NIM position encoding modules (PEM). The PEMs communicate with the host computer via USB. The detector when placed at 1.1 m, subtends 30° (2θ) at each step and covers 120° in 4 steps. When the detector is placed at 1.6 m it subtends 20° at each step and covers 120° in 6 steps. The instrument supports both low and high temperature sample environment. The instrument supports both low and high temperature sample environment. The diffractometer is a state-of-the art technology for diffraction study in our country.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of low-frequency operational limit of proposed ITER low-field-side reflectometer waveguide run including miter bends

The present design concept for the ITER low-field-side reflectometer transmission line (TL) consists of an ~40 m long, 6.35 cm diameter helically corrugated waveguide (WG) together with ten 90° miter bends. This paper presents an evaluation of the TL performance at low frequencies (33-50 GHz) where the predicted HE11 mode ohmic and mode conversion losses start to increase significantly. Quasi-optical techniques were used to form a near Gaussian beam to efficiently couple radiation in this frequency range into the WG. We observed that the output beams from the guide remained linearly polarized with cross-polarization power levels of ~1.5%-3%. The polarization rotation due to the helical corrugations was in the range ~1°-3°. The radiated beam power profiles typically show excellent Gaussian propagation characteristics at distances >20 cm from the final exit aperture. The round trip propagation loss was found to be ~2.5 dB at 50 GHz and ~6.5 dB at 35 GHz, showing an inverse increase with frequency. This was consistent with updated calculations of miter bend and ohmic losses. At low frequencies (33-50 GHz), the mode purity remained very good at the exit of the waveguide, and the losses are perfectly acceptable for operation in ITER. Finally, the primary challenge may come from the future addition of a Gaussian telescope and other filter components within the corrugated guide, which will likely introduce additional perturbations to the beam profile and an increase in mode-conversion loss.

47 OTHER INSTRUMENTATION↗

Monitoring SARS-CoV-2 in wastewater [Slides]

The monitoring of SARS-CoV-2 through individual testing is subject to inaccuracies. Wastewater biosurveillance has been used around the world to detect the presence of drugs, viruses, and other chemicals present in a population. Fecal shedding of SARS-CoV-2 implies that wastewater can be analyzed in order to detect varying levels of the virus within a given community. Pepper Mild Mottle Virus is present consistently in human fecal matter, and can be used to normalize the amount of SARS-CoV-2 detected. In this experiment, the amount of SARS-CoV-2 in the wastewater sample was compared to the amount of PMMoV present. Wastewater samples were separated into three fractions: direct wastewater, a solid pellet, and filter paper extract. An RT-qPCR test was used on the extracted RNA from each fraction to detect the relative amount of SARS-CoV-2 and PMMoV copies in each sample. The amount of SARS-CoV-2 was successfully normalized to the amount of PMMoV.

59 BASIC BIOLOGICAL SCIENCES↗

A general purpose wideband optical spatial frequency spectrum analyzer

The light scattered at various angles by a transparent media is studied. An example of these applications is the optical Fourier spectrum measurement resulting from various spatial frequencies which were recorded on a photographic emulsion. A method for obtaining these measurements consists of illuminating the test object with parallel monochromatic light. A stationary lens, placed in the resulting wavefield at a distance of one focal length from the object, will focus parallel waves emanating from the test object at a point lying in the focal plane of the lens. A light detector with a small filtering aperture is then used to measure the intensity variation of the light in the focal or transform plane of the lens. Such measurements require the use of a lens which is highly corrected for all of the common aberrations except chromatic aberration.

Ballard, G. S.↗

Development of a household waste treatment subsystem, volume 1

The domestic waste treatment subsystem was developed to process the daily liquid and non-metallic solid wastes provided by a family of four people. The subsystem was designed to be connected to the sewer line of a household which contained water conservation features. The system consisted of an evaporation technique to separate liquids from solids, an incineration technique for solids reduction, and a catalytic oxidizer for eliminating noxious gases from evaporation and incineration processes. All wastes were passed through a grinder which masticated the solids and deposited them in a settling tank. The liquids were transferred through a cleanable filter into a holding tank. From here the liquids were sprayed into an evaporator and a spray chamber where evaporation occurred. The resulting vapors were processed by catalytic oxidation. Water and latent energy were recovered in a combination evaporator/condenser heat exchanger. The solids were conveyed into an incinerator and reduced to ash while the incineration gases were passed through the catalytic oxidizer along with the processed water vapor.

Gresko, T. M.↗