Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “consistency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Hydrothermal syntheses, structural, Raman, and luminescence studies of Cm[M(CN){sub 2}]{sub 3}.3H{sub 2}O and Pr[M(CN){sub 2}]{sub 3}.3H{sub 2}O (M=Ag, Au)

We have prepared Cm[Au(CN){sub 2}]{sub 3}.3H{sub 2}O and Cm[Ag(CN){sub 2}]{sub 3}.3H{sub 2}O as a part of our continuing investigations into the chemistry of the 5f-elements' dicyanometallates. Single crystals of Cm[Au(CN){sub 2}]{sub 3}.3H{sub 2}O were obtained from the reaction of CmCl{sub 3} and KAu(CN){sub 2} under mild hydrothermal conditions. Due to similarities in size, the related praseodymium compounds were also synthesized and characterized for comparison with the actinide systems. The compounds crystallize in the hexagonal space group P6{sub 3}/mcm, where the curium and the transition metals interconnect through cyanide bridging. Crystallographic data (Mo K{alpha}, {lambda}=0.71073 A): Cm[Au(CN){sub 2}]{sub 3}.3H{sub 2}O (1), a=6.6614(5) A, c=18.3135(13) A, V=703.77(9), Z=2; Pr[Au(CN){sub 2}]{sub 3}.3H{sub 2}O (3), a=6.6662(8) A, c=18.497(3) A, V=711.83(17), Z=2; Pr[Ag(CN){sub 2}]{sub 3}.3H{sub 2}O (4), a=6.7186(8) A, c=18.678(2) A, V=730.18(14), Z=2. The Cm{sup 3+} and/or Pr{sup 3+} ions are coordinated to six N-bound CN{sup -} groups resulting in a trigonal prismatic arrangement. Three oxygen atoms of coordinated water molecules tricap the trigonal prismatic arrangement providing a coordination number of nine for the f-elements. The curium ions in both compounds exhibit a strong red emission corresponding to the {sup 6}D{sub 7/2}{yields}{sup 8}S{sub 7/2} transition. This transition is observed at 16,780 cm{sup -1}, with shoulders at 17,080 and 16,840 cm{sup -1} for the Ag complex, while the emission is red shifted by {approx}100 cm{sup -1} in the corresponding gold complex. The Pr systems also provide well-resolved emissions upon f-f excitation. - Graphical abstract: Coordination polymeric compounds between a trans-plutonium element, curium and transition metal ions, gold(I) and silver(I), were prepared using the hydrothermal synthetic procedure. The curium ion and the transition metals are interconnected through cyanide bridging. The Cm ion has a tricapped trigonal prismatic coordination environment with coordination number of nine. Detail photoluminescence studies of the complexes are also reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Consistency of vendor-specified activity values for {sup 192}Ir brachytherapy sources

A long-term comparison was done between the manufacturer-stated {sup 192}Ir activity and the measured {sup 192}Ir activities determined with a well-type ionization chamber. Sources for a Nucletron Micro Selectron high-dose-rate (HDR) unit were used for this purpose. The radioactive sources reference activities were determined using a PTW well-type ionization chamber traceable to the National Institute of Standards and Technology Primary Calibration Laboratory. The measurements were taken in a period of 56 months with 17 different radioactive sources. The manufacturer stated activities were taken from the source calibration certificate provided by the manufacturer. These values were compared with the measured activities. The results have shown that both the percentage deviation of the monthly control measurements with the well-type chamber and the ratio between the measured activities to the manufacturer-stated value lie within {+-} 2.5%. These results were compared with similar published data and with uncertainty level (3% of the mean and 5% maximum deviation from mean) for brachytherapy sources calibration recommended by the AAPM. It was concluded that a threshold level of {+-}2.5% can be used as a suitable quality assurance indicator to spot problems in our department. The typical {+-}5% uncertainty as provided by the manufacturers may be tightened to {+-}3% to be more in line with published AAPM reports.

61 RADIATION PROTECTION AND DOSIMETRY↗