Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Exclusive photoproduction of quarkonium at the LHC energies within the color dipole approach

The exclusive photoproduction of ψ(2S) meson was investigated and the coherent and the incoherent contributions were evaluated. The light-cone dipole formalism was considered in this analysis and predictions are done for PbPb collisions at the CERN-LHC energy of 2.76 TeV. A comparison is done to the recent ALICE Collaboration data for the ψ(1S) state photoproduction with good agreement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Solid immersion lenses for enhancing the optical resolution of thermal and electroluminescence mapping of GaN-on-SiC transistors

Solid immersion lenses (SILs) are shown to greatly enhance optical spatial resolution when measuring AlGaN/GaN High Electron Mobility Transistors (HEMTs), taking advantage of the high refractive index of the SiC substrates commonly used for these devices. Solid immersion lenses can be applied to techniques such as electroluminescence emission microscopy and Raman thermography, aiding the development device physics models. Focused ion beam milling is used to fabricate solid immersion lenses in SiC substrates with a numerical aperture of 1.3. A lateral spatial resolution of 300 nm is demonstrated at an emission wavelength of 700 nm, and an axial spatial resolution of 1.7 ± 0.3 μm at a laser wavelength of 532 nm is demonstrated; this is an improvement of 2.5× and 5×, respectively, when compared with a conventional 0.5 numerical aperture objective lens without a SIL. These results highlight the benefit of applying the solid immersion lenses technique to the optical characterization of GaN HEMTs. Further improvements may be gained through aberration compensation and increasing the SIL numerical aperture.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real and complex valued geometrical optics inverse ray-tracing for inline field calculations

In this work, a 3-D ray based model for computing laser fields in dissipative and amplifying media is presented. The eikonal equation is solved using inverse ray-tracing on a dedicated nonstructured 3-D mesh. Inverse ray-tracing opens the possibility of using Complex Geometrical Optics (CGO), for which we propose a propagation formalism in a finite element mesh. Divergent fields at caustics are corrected using an etalon integral method for fold-type caustics. This method is successfully applied in dissipative media by modifying the ray-ordering and root selection rules, thereby allowing one to reconstruct the field in the entire caustic region. In addition, we demonstrate how caustics in the CGO framework can disappear entirely for sufficiently dissipative media, making the complex ray approach valid in the entire medium. CGO is shown to offer a more precise modeling of laser refraction and absorption in a dissipative medium when compared to Geometrical Optics (GO). In the framework of Inertial Confinement Fusion (ICF), this occurs mostly at intermediate temperatures or at high temperatures close to the critical density. Additionally, GO is invalid at low temperatures if an approximated expression of the permittivity is used. The inverse ray-tracing algorithm for GO and CGO is implemented in the IFRIIT code, in the framework of a dielectric permittivity described in 3-D using a piecewise linear approximation in tetrahedrons. Fields computed using GO and CGO are compared to results from the electromagnetic wave solver LPSE. Excellent agreement is obtained in 1-D linear and nonlinear permittivity profiles. Good agreement is also obtained for ICF-like Gaussian density profiles in 2-D. Finally, we demonstrate how the model reproduces Gaussian beam diffraction using CGO. The IFRIIT code will be interfaced inline to 3-D radiative hydrodynamic codes to describe the nonlinear laser plasma interaction in ICF and high-energy-density plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of electron–electron interactions on the emission characteristics of ultracold, nanoscale photoemission-based electron sources

For nearly 60 years, cold field emitters have been the source of choice for electron microscopy due to their high brightness and relatively low energy spread. In this paper, we have examined an alternative: nanoscale electron sources based on near-threshold photoemission. While these sources have not yet been realized, they hold the potential to produce significantly brighter beams than cold field emitters. We model electron–electron Coulomb interactions in beams emitted from such sources to calculate the impact of these interactions on the brightness and the energy spread. Our results show that these sources can theoretically deliver more than an order of magnitude brighter electron beams compared to cold field emitters along with more than an order of magnitude smaller energy spread, before being limited by the Coulomb interactions. Electron sources with such high brightness and low energy spread would be transformational for electron microscopy, enabling electron energy loss-based vibrational spectroscopy at the sub-nanometer scale.

Gevorkyan, G S↗

Influence of the resonator parameters and spatially nonuniform amplification on the spatial structure of the fundamental mode of stable resonator lasers

The combined influence of the resonator parameters and spatially nonuniform axially symmetric amplification distribution in a four-level active medium on the spatial structure of the fundamental mode of laser radiation is studied numerically by the Fox-Li method. The model of two beams interacting due to the spatial amplification nonuniformity is used to obtain simple analytic estimates. The transition of the spatial structure of the fundamental mode from the Gaussian one to the structure formed by a set of Laguerre-Gaussian beams is studied. It is shown that near the degenerate configurations of the resonator a decrease in the diameter of the pump beam leads to an increase in the number of Laguerre-Gaussian beams forming the fundamental mode. It is found that the range of detunings from the strong degeneracy within which substantial differences of the spatial structure of the fundamental mode from the Gaussian structure are realised, increases with increasing the gain. (resonators. modes)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Regarding the optimization of O1-mode ECRH and the feasibility of EBW startup on NSTX-U

Recently published scenarios for fully non-inductive startup and operation on the National Spherical Torus eXperiment Upgrade (NSTX-U) [Menard J et al 2012 Nucl. Fusion 52 083015] show Electron Cyclotron Resonance Heating (ECRH) as an important component in preparing a target plasma for efficient High Harmonic Fast Wave and Neutral Beam heating. The modelling of the propagation and absorption of EC waves in the evolving plasma is required to define the most effective window of operation, and to optimize the launcher geometry for maximal heating and current drive during this window. Here in this paper, we extend a previous optimization of O1-mode ECRH on NSTX-U to account for the full time-dependent performance of the ECRH using simulations performed with TRANSP. We find that the evolution of the density profile has a prominent role in the optimization by defining the time window of operation, which in certain cases may be a more important metric to compare launcher performance than the average power absorption. This feature cannot be captured by analysis on static profiles, and should be accounted for when optimizing ECRH on any device that operates near the cutoff density. Additionally, the utility of the electron Bernstein wave (EBW) in driving current and generating closed flux surfaces in the early startup phase has been demonstrated on a number of devices. Using standalone GENRAY simulations, we find that efficient EBW current drive is possible on NSTX-U if the injection angle is shifted below the midplane and aimed towards the top half of the vacuum vessel. However, collisional damping of the EBW is projected to be significant, in some cases accounting for up to 97\% of the absorbed EBW power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predicting the rotation profile in ITER

Determining the toroidal rotation for future tokamaks like ITER is a challenging and important problem. By combining empirical scalings for the intrinsic rotation at the top of the pedestal with the expected neutral beam torque and modeling of momentum transport, the toroidal rotation profile for ITER is predicted with TGYRO using TGLF (SAT0 and SAT1). On axis rotation exceeds 20 krad s –1 and the E x B shear is significant enough to reduce turbulent transport and significantly increase confinement and fusion power when comparing to cases that ignore the effect of rotation. Here, the prediction of the rotation at the top of the pedestal is made with increased confidence due to experiments and modeling in DIII-D that have determined the importance of fast-ion and neutral particle transport effects on intrinsic rotation at this location. In particular, the effect of neutral particles on momentum transport in the pedestal region is found to be insignificant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantifying electron cyclotron power deposition broadening in DIII-D and the potential consequences for the ITER EC system

Abstract The injection of electron cyclotron (EC) waves fulfills a number of important tasks in nuclear fusion devices for which detailed knowledge of the spatial power deposition profile is critical. This deposition profile is commonly determined using forward models such as beam or ray tracing. Recent numerical and experimental studies have shown that small-angle scattering of the EC beam as it passes through the turbulent plasma edge can cause significant broadening of the effective deposition profile, leading to considerable underestimation of the deposition width by forward methods. However, traditional inverse methods to determine the deposition profile from measurements overestimate the deposition profile width due to transport broadening. In this work, we implement three novel methods to resolve the EC power deposition profile from measurements that counteract transport broadening by simultaneously resolving transport and power deposition. We validate their assumptions and compare the results from these methods to the traditional break-in-slope method as well as to the TORAY ray-tracing code in a set of DIII-D discharges spanning five different confinement modes. We show that the four different inverse methods, novel and established, paint a consistent picture of deposition broadening. Specifically, we show that the measured power deposition profile is between 1.6 and 3.6 times wider than the TORAY profiles. Moreover, we show the considerable consequences that this level of broadening can have for ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mapping gravitational lensing of the CMB using local likelihoods

We present a new estimation method for mapping the gravitational lensing potential from observed CMB intensity and polarization fields. Our method uses Bayesian techniques to estimate the average curvature of the potential over small local regions. These local curvatures are then used to construct an estimate of a low pass filter of the gravitational potential. By utilizing Bayesian/likelihood methods one can easily overcome problems with missing and/or nonuniform pixels and problems with partial sky observations (E- and B-mode mixing, for example). Moreover, our methods are local in nature, which allow us to easily model spatially varying beams, and are highly parallelizable. We note that our estimates do not rely on the typical Taylor approximation which is used to construct estimates of the gravitational potential by Fourier coupling. We present our methodology with a flat sky simulation under nearly ideal experimental conditions with a noise level of 1 {mu}K-arcmin for the temperature field, {radical}(2) {mu}K-arcmin for the polarization fields, with an instrumental beam full width at half maximum (FWHM) of 0.25 arcmin.

79 ASTRONOMY AND ASTROPHYSICS↗

Properties of hot-spot emission in a warm plastic-shell implosion on the OMEGA laser system

A warm plastic-shell implosion was performed on the OMEGA laser system. The measured corona plasma evolution and shell trajectory in the acceleration phase are reasonably simulated by the one-dimensional LILAC simulation including the nonlocal and cross-beam energy transfer models. The results from analytical thin-shell model reproduce the time-dependent shell radius by LILAC simulation, and also the hot-spot x-ray emissivity profile at stagnation predicted by Spect3D. In the Spect3D simulations within a clean implosion, a “U”-shaped hot-spot radius evolution can be observed with the Kirkpatrick-Baez microscope response (the photon energy is from 4 to 8 keV). However, a fading away hot-spot radius evolution was measured in OMEGA warm plastic-shell implosion because of mixings. In order to recover the measured hot-spot x-ray emissivity profile at stagnation, a non-isobaric hot-spot model is built, and the normalized hot-spot temperature, density, and pressure profiles (normalized to the corresponding target-center values) are obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Passive Environment-Assisted Quantum Communication with GKP States

Bosonic pure-loss channel, which represents the process of photons decaying into a vacuum environment, has zero quantum capacity when the channel’s transmissivity is less than 50%. Modeled as a beam splitter interaction between the system and its environment, the performance of bosonic pure-loss channel can be enhanced by controlling the environment state. We show that by choosing the ideal Gottesman-Kitaev-Preskill (GKP) states for the system and its environment, perfect transmission of quantum information through a beam splitter is achievable at arbitrarily low transmissivities. Our explicit constructions allow for experimental demonstration of the improved performance of a quantum channel through passive environment assistance, which is potentially useful for quantum transduction where the environment state can be naturally controlled. In practice, it is crucial to consider finite-energy constraints, and high-fidelity quantum communication through a beam splitter remains achievable with GKP states at the few-photon level.

Wang, Zhaoyou [Univ. of Chicago, IL (United States↗

Optimizing the dynamic range extension of a radiochromic film dosimetry system

The authors present a radiochromic film dosimetry protocol for a multicolor channel radiochromic film dosimetry system consisting of the external beam therapy (EBT) model GAFCHROMIC film and the Epson Expression 1680 flat-bed document scanner. Instead of extracting only the red color channel, the authors are using all three color channels in the absorption spectrum of the EBT film to extend the dynamic dose range of the radiochromic film dosimetry system. By optimizing the dose range for each color channel, they obtained a system that has both precision and accuracy below 1.5%, and the optimized ranges are 0-4 Gy for the red channel, 4-50 Gy for the green channel, and above 50 Gy for the blue channel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of statistical iterative reconstruction for dedicated breast CT

Purpose: Dedicated breast CT has great potential for improving the detection and diagnosis of breast cancer. Statistical iterative reconstruction (SIR) in dedicated breast CT is a promising alternative to traditional filtered backprojection (FBP). One of the difficulties in using SIR is the presence of free parameters in the algorithm that control the appearance of the resulting image. These parameters require tuning in order to achieve high quality reconstructions. In this study, the authors investigated the penalized maximum likelihood (PML) method with two commonly used types of roughness penalty functions: hyperbolic potential and anisotropic total variation (TV) norm. Reconstructed images were compared with images obtained using standard FBP. Optimal parameters for PML with the hyperbolic prior are reported for the task of detecting microcalcifications embedded in breast tissue.Methods: Computer simulations were used to acquire projections in a half-cone beam geometry. The modeled setup describes a realistic breast CT benchtop system, with an x-ray spectra produced by a point source and an a-Si, CsI:Tl flat-panel detector. A voxelized anthropomorphic breast phantom with 280 μm microcalcification spheres embedded in it was used to model attenuation properties of the uncompressed woman's breast in a pendant position. The reconstruction of 3D images was performed using the separable paraboloidal surrogates algorithm with ordered subsets. Task performance was assessed with the ideal observer detectability index to determine optimal PML parameters.Results: The authors' findings suggest that there is a preferred range of values of the roughness penalty weight and the edge preservation threshold in the penalized objective function with the hyperbolic potential, which resulted in low noise images with high contrast microcalcifications preserved. In terms of numerical observer detectability index, the PML method with optimal parameters yielded substantially improved performance (by a factor of greater than 10) compared to FBP. The hyperbolic prior was also observed to be superior to the TV norm. A few of the best-performing parameter pairs for the PML method also demonstrated superior performance for various radiation doses. In fact, using PML with certain parameter values results in better images, acquired using 2 mGy dose, than FBP-reconstructed images acquired using 6 mGy dose.Conclusions: A range of optimal free parameters for the PML algorithm with hyperbolic and TV norm-based potentials is presented for the microcalcification detection task, in dedicated breast CT. The reported values can be used as starting values of the free parameters, when SIR techniques are used for image reconstruction. Significant improvement in image quality can be achieved by using PML with optimal combination of parameters, as compared to FBP. Importantly, these results suggest improved detection of microcalcifications can be obtained by using PML with lower radiation dose to the patient, than using FBP with higher dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose reconstruction for real-time patient-specific dose estimation in CT

Purpose: Many recent computed tomography (CT) dose reduction approaches belong to one of three categories: statistical reconstruction algorithms, efficient x-ray detectors, and optimized CT acquisition schemes with precise control over the x-ray distribution. The latter category could greatly benefit from fast and accurate methods for dose estimation, which would enable real-time patient-specific protocol optimization. Methods: The authors present a new method for volumetrically reconstructing absorbed dose on a per-voxel basis, directly from the actual CT images. The authors’ specific implementation combines a distance-driven pencil-beam approach to model the first-order x-ray interactions with a set of Gaussian convolution kernels to model the higher-order x-ray interactions. The authors performed a number of 3D simulation experiments comparing the proposed method to a Monte Carlo based ground truth. Results: The authors’ results indicate that the proposed approach offers a good trade-off between accuracy and computational efficiency. The images show a good qualitative correspondence to Monte Carlo estimates. Preliminary quantitative results show errors below 10%, except in bone regions, where the authors see a bigger model mismatch. The computational complexity is similar to that of a low-resolution filtered-backprojection algorithm. Conclusions: The authors present a method for analytic dose reconstruction in CT, similar to the techniques used in radiation therapy planning with megavoltage energies. Future work will include refinements of the proposed method to improve the accuracy as well as a more extensive validation study. The proposed method is not intended to replace methods that track individual x-ray photons, but the authors expect that it may prove useful in applications where real-time patient-specific dose estimation is required.

60 APPLIED LIFE SCIENCES↗

SU-F-P-07: Applying Failure Modes and Effects Analysis to Treatment Planning System QA

Purpose: A small-scale implementation of Failure Modes and Effects Analysis (FMEA) for treatment planning system QA by utilizing methodology of AAPM TG-100 report. Methods: FMEA requires numerical values for severity (S), occurrence (O) and detectability (D) of each mode of failure. The product of these three values gives a risk priority number (RPN). We have implemented FMEA for the treatment planning system (TPS) QA for two clinics which use Pinnacle and Eclipse TPS. Quantitative monthly QA data dating back to 4 years for Pinnacle and 1 year for Eclipse have been used to determine values for severity (deviations from predetermined doses at points or volumes), and occurrence of such deviations. The TPS QA protocol includes a phantom containing solid water and lung- and bone-equivalent heterogeneities. Photon and electron plans have been evaluated in both systems. The dose values at multiple distinct points of interest (POI) within the solid water, lung, and bone-equivalent slabs, as well as mean doses to several volumes of interest (VOI), have been re-calculated monthly using the available algorithms. Results: The computed doses vary slightly month-over-month. There have been more significant deviations following software upgrades, especially if the upgrade involved re-modeling of the beams. TG-100 guidance and the data presented here suggest an occurrence (O) of 2 depending on the frequency of re-commissioning the beams, severity (S) of 3, and detectability (D) of 2, giving an RPN of 12. Conclusion: Computerized treatment planning systems could pose a risk due to dosimetric errors and suboptimal treatment plans. The FMEA analysis presented here suggests that TPS QA should immediately follow software upgrades, but does not need to be performed every month.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRB-04: 4π Dynamic Conformal Arc Therapy Dynamic Conformal Arc Therapy (DCAT) for SBRT

Purpose: To develop an efficient and effective trajectory optimization methodology for 4π dynamic conformal arc treatment (4π DCAT) with synchronized gantry and couch motion; and to investigate potential clinical benefits for stereotactic body radiation therapy (SBRT) to breast, lung, liver and spine tumors. Methods: The entire optimization framework for 4π DCAT inverse planning consists of two parts: 1) integer programming algorithm and 2) particle swarm optimization (PSO) algorithm. The integer programming is designed to find an optimal solution for arc delivery trajectory with both couch and gantry rotation, while PSO minimize a non-convex objective function based on the selected trajectory and dose-volume constraints. In this study, control point interaction is explicitly taken into account. Beam trajectory was modeled as a series of control points connected together to form a deliverable path. With linear treatment planning objectives, a mixed-integer program (MIP) was formulated. Under mild assumptions, the MIP is tractable. Assigning monitor units to control points along the path can be integrated into the model and done by PSO. The developed 4π DCAT inverse planning strategy is evaluated on SBRT cases and compared to clinically treated plans. Results: The resultant dose distribution of this technique was evaluated between 3D conformal treatment plan generated by Pinnacle treatment planning system and 4π DCAT on a lung SBRT patient case. Both plans share the same scale of MU, 3038 and 2822 correspondingly to 3D conformal plan and 4π DCAT. The mean doses for most of OARs were greatly reduced at 32% (cord), 70% (esophagus), 2.8% (lung) and 42.4% (stomach). Conclusion: Initial results in this study show the proposed 4π DCAT treatment technique can achieve better OAR sparing and lower MUs, which indicates that the developed technique is promising for high dose SBRT to reduce the risk of secondary cancer.

60 APPLIED LIFE SCIENCES↗