Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Magnetic Calorimeter Arrays with High Sensor Inductance and Dense Wiring

We describe prototype arrays of magnetically coupled microcalorimeters fabricated with an approach scalable to very large format arrays. The superconducting interconnections and sensor coils have sufficiently low inductance in the wiring and sufficiently high inductance in the coils in each pixel, to enable arrays containing greater than 4000 sensors and 100,000 X-ray absorbers to be used in future astrophysics missions such as Lynx. We have used projection lithography to create submicron patterns (e.g., 400-nanometer-lines and spaces) in our niobium sensor coils and wiring, integrated with gold-erbium sensor films and gold X-ray absorbers. Our prototype devices will explore the device physics of metallic magnetic calorimeters as feature sizes are reduced to nanoscale.

Magnetism↗

Solar Array (Radiated/Non-Radiated): Materials Characterization and Cryogenic Thermal Cycling Qualification for the Planned Europa Clipper Mission (ECM)

Two special instruments were custom built for our critical study and manufactured and employed to test the SA materials of interest to cryogenic temperature conditions. We have procured custom manufactured two independent systems such as Thermo -Mechanical Analyzer (TMA) with Three Point Bend Probe (TPBP) module and Dilatometer. TMA can be used to measure Young’ s modulus or elastic modulus (e -modulus). Dilatometer can be used to measure Co -efficient of Thermal Expansion (CTE). We have optimized the materials configuration to measure physical properties of radiated and non -radiated materials for CTE and e -modulus, which will be useful to assess materials and processes reliability for cryogenic temperature applications. We have successfully implemented for some materials that are of interest to solar panels for the planned ECM project to measure CTE and Young's modulus. Also a separate study was undertaken to thermal cycle qualify SAs for ECM project. One can do thermal cycling to temperatures of 50 K and 133 K using liquid Helium (Lq He). This is in reality exorbitantly too expensive and is also inefficient. Furthermore, this is not technically controllable test to 133 K and 50 K temperatures. This is also too expensive to accomplish. Therefore, a vacuum set -up was made along with a cryostat successfully. This is a closed loop system where we do not lose the Helium gas. We were able to get to 35 K for a given test coupon size. These temperatures are lower than what we would intend to qualify the solar array technologies. This will allow to have some margin at cold temperatures. We successfully completed the qualification of solar array technologies down to 50 K temperatures. This is the first time we are reporting this accomplishment. In this paper, we will present the solar array materials properties for cryogenic temperatures down to 20 K temperatures and the thermal cycling qualification test results from 133 K to 50 K for three times the mission life of 120 thermal cycles to meet JPL Design.

Ramesham, Rajeshuni↗

Electrospray Thruster Performance with Microfabricated Emitter Arrays and Indium Propellant

The feasibility of a microfabricated indium-fueled electrospray thruster with excellent performance was demonstrated. High efficiency electrospray thrusters with microfabricated components are under development for very compact, distributable propulsion systems that can be employed on both very small and large spacecraft with 10X improvement over SOA in mass, volume and specific impulse The critical components of this technology are the microfabricated emitter arrays and the capillary force driven indium feed system. Grey scale electron-beam lithography patterning and reactive ion dry etching provided the required micron-scale etch precision and uniformity across an array of 400 emitters in 1 cm2. Initial tests of single microfabricated silicon emitters demonstrated better performance than industry standard single emitters and the performance required to achieve 200 micronewtons when scaled up to a thruster with 400 emitters in 1 cm2. Arrays of emitters tested in a preliminary prototype Microfluidic Electrospray Propulsion (MEP) thruster assembly demonstrated stable performance at estimated thrust levels of 5, 50, and 120 µN at extraction voltages less than 4 kV. Current stability was within 0.15 % at 120 µN with only 1.5% of the emitter current collected by the extractor electrode. Post-test inspections revealed that more than 99% of the 400 emitters were electrospraying during the test. Specific impulse was estimated to be >3100 s from measurements of total charge and consumed indium mass at an emitter voltage of 1470 V. The results of this investigation suggest that microfabricated indium electrospray thruster technology is both feasible and capable of excellent performance as a highly compact microthruster.

Marrese-Reading, Colleen M.↗

HgCdTe Avalanche Photodiode Array Detectors with Single Photon Sensitivity and Integrated Detector Cooler Assemblies for Space Lidar Applications

A HgCdTe avalanche photodiode (APD) focal plane array assembly with linear mode photon-counting capability has been developed for space lidar applications. An integrated detector cooler assembly (IDCA) has been built using a miniature Stirling cooler. A microlens array has been included to improve the fill factor. The HgCdTe APD has a spectral response from 0.9- to 4.3-μm wavelengths, a photon detection efficiency as high as 70%, and a dark count rate of <250 kHz at 110 K. The mass of the IDCA is 0.8 kg and the total electrical power consumption is about 7 W. The HgCdTe APD arrays have been characterized at NASA Goddard Space Flight Center. A series of environmental tests have been conducted for the IDCAs, including vibration, thermal cycling, and thermal vacuum tests. A description of the device and the test results at NASA are given in this paper.

Sun, Xiaoli↗

Small and Lightweight Laser Retro-Reflector Arrays for Lunar Landers

A set of small and lightweight laser retro-reflector arrays (LRAs) was fabricated and tested for use on lunar landersunder NASA's Commercial Lunar Payload Service program. Each array contains eight 1.27-cm-diameter cornercube retro-reflectors mounted on a dome-shaped aluminum structure. The arrays are 5.0cmin diameter at the base,1.6 cm in height, and 20 g in mass. They can be tracked by an orbiting laser altimeter, such as the Lunar OrbiterLaser Altimeter, froma distance of a few hundred kilometers or by a landing lidar on future lunar landers. TheLRAsdemonstrated a diffraction-limited optical performance. They were designed and tested to survive and function ontheMoon for decades,well after the lander missions are completed.

Sun, Xiaoli↗

Transformational Solar Array Option I Final Report

This report summarizes the work performed under NASA contract NNC16CA19C from May 2, 2017 through April 2, 2018. This work is directed toward meeting the goals of the associated NASA NRA and, of course, the requirements of the contract. In brief, the goals are: (1) Over 47% beginning of life cell efficiency at 5 AU and -125 °C (2) Over 32% end of life efficiency at the blanket level at 50 W m-2, -125 °C and 4E15 1 MeV e cm-2 (3) Over 8 W kg-1 at EOL for the entire array including structure, deployment, and pointing mechanisms using beginning of life performance. (4) A stowed packaging density of greater than 66 kW m-3 (5) An ability to survive launch and numerous deploy retract cycles without degradation (6) An output higher than 300 V (7) An ability to operate in a plasma generated by xenon thrusters, typically 1E8 cm-3 ions with an average energy of 2 eV (8) A design compatible with electrostatic and magnetic cleanliness (9) Record breaking inverted metamorphic (IMM) 6 junction solar cells (10) IMM solar cells that have no anomalous flat spot behavior at low irradiance and low temperature (11) A mock-up production line for the low-cost manufacture of spacecraft blanket arrays. The Option I phase of the project continued efforts, started in the base-phase, to eliminate or reduce to very low levels the flat spots that reduce power to an unacceptable value in a significant percentage of cells and to reduce outgassing contamination of the concentrators to acceptable levels. Option I adds tasks to increase the efficiency of IMM cells from those produced in the Base Phase, to eliminate delamination of the coatings that were present in previous versions of the concentrator mirrors, to evaluate pressure sensitive adhesive as a method of fixing solar cell assemblies to blankets, to design a magnetically clean brake for ROSA, to test the robustness of a sample blanket in deploy and retract, to test for the adequate performance of a blanket in vibration and thermal environments, and to define the capital equipment needed to optimize production of the Transformational Array. 5 Work for this Final Report showed that the greatest likely improvement in the solar cells would be by emphasizing the effort for the IMM4 solar cells and stopping work on other IMM cells. For this phase, the solar cell work was primarily on the IMM4 cells with little work on IMM5 and none on IMM6 cells.

Gaddy, Edward↗

Structural Analysis Methods for the Roll-Out Solar Array Flight Experiment

The Roll-Out Solar Array (ROSA) flight experiment was launched to the International Space Station (ISS) on June 3rd, 2017. ROSA is an innovative, lightweight solar array with a flexible substrate that makes use of the stored strain energy in its composite structural members to provide deployment without the use of motors. This paper discusses the effort to model the structural dynamics of ROSA using finite element modeling. Two distinct and agnostic approaches were used by separate teams to assess the structural dynamics of the solar array prior to ground vibrational testing and flight testing. Results from each approach are compared to measured dynamics from accelerometers and photogrammetry data gathered on orbit. Advantages and disadvantages of each approach are discussed as are preliminary efforts to calibrate the models to the empirical data for the benefit of future modeling efforts on similar space structures.

Chamberlain, Matthew K.↗

Evidence for Arcing on the International Space Station Solar Arrays

The International Space Station (ISS) is powered by a set of 160 V photovoltaic arrays (PVA) in the US sector. Arcing thresholds for the ISS PVAs measured in the laboratory are shown to vary from -210 V to -457 V depending on the ambient plasma density, where low arcing threshold occurs at high plasma densities. Arcing of ISS PVAs on-orbit is unlikely under normal operating conditions. The net potential of a solar cell relative to space depends on the position of the cell within a string, the (vxB)•L contribution to the potential at the location of the cell, and the frame potential of ISS due to solar array charging. Net potentials on a cell will reach the arcing threshold only on rare occasions. However, the situation changes when damaged PVA strings are considered. Open circuit strings can exhibit voltages exceeding -300 V when the strings are shunted. Under these conditions the local potential on the damaged string can easily exceed arcing thresholds at the low end of the -210 V to -457 V range for ISS PVAs. Because arcing to space on the array will remove some fraction of the net negative charge on the ISS, transient variations in the frame potential are expected during the electrostatic discharge events. We report a new class of transient ISS frame potential variations consistent with arcing on open strings using data from the ISS Floating Potential Measurement Unit’s Floating Potential Probe instrument.

Minow, Joseph I.↗

Boundary Layer Transition Induced by Distributed Roughness Array

The effects of a finite, spanwise-periodic array of cylindrical roughness elements on boundary layer transition over a NACA 0012 airfoil are investigated at a chord-based Reynolds number of 1.44×105 by using hotwire anemometry and infrared thermography. Both the number and the spanwise spacing of roughness elements in the array are varied in order to study their effect on the wake flow topology. Spanwise interaction between the roughness elements has an effect on the connection and the merging of neighbouring low-speed regions, which results in the formation of merged low-speed blobs (MLSs) that modify the spatial distribution and the amplitudes of the velocity streaks. When the spanwise distance between adjacent roughness elements equals 1.5 times the cylinder diameter, the transition location moves rapidly upstream. In this case, the two neighbouring low-speed regions overlap with each other in the near wake of the roughness, leading to the maximum growth in the velocity streak amplitude and the velocity fluctuations. The number of roughness elements affects the total number of MLSs within the boundary layer. For a single MLS behind a pair of cylinders, the Kelvin-Helmholtz instability dominates the growth of velocity fluctuations around the three-dimensional shear layers. When three cylinders are placed in the array, two MLSs appear in the near wake, which coalesce in to one low-speed blob downstream before the onset of transition, revealing the importance of Kelvin-Helmholtz instability.

Qingqing Ye↗

Thermal Impact of Cosmic Ray Interaction with an XRay Microcalorimeter Array

The X-ray Integral Field Unit (X-IFU) instrument on the Athena mission will be positioned at the Lagrangian point L2 and be subject to cosmic rays generated by astrophysics sources, primarily relativistic protons. Previous simulations have shown that particles of energy higher than 150 MeV will make it through the outer layers of the satellite. They will reach the detector wafer with a rate of 3 cts/sq. cm/s and a most probable energy deposited in the Si frame supporting the array at 150 keV. These events can affect the energy resolution of the detectors through the thermal fluctuations that they produce. This study assesses this potential problem and discusses two suggested design approaches to decrease the impact of cosmic ray in order to limit their effect to their allocation of 0.2 eV within the Athena/X-IFU energy-resolution budget. The first is the addition of a coating layer of high heat capacity material (e.g., Pd) and the second is the splitting of this coating into two thermal regions near the TES array to keep the heat away from the array. Implementing these two features is predicted to cause a decrease in the number of events above 1 μK by more than a factor 10 to ~ 1.5 cps when compared to an equivalent design without these features.

Antoine R. Miniussi↗

Thermal crosstalk measurements and simulations for an X-ray microcalorimeter array

Arrays of high-density microcalorimeters require careful heat sinking in order to minimize the thermal crosstalk between nearby pixels. For the array of microcalorimeters developed for the Athena X-ray Integral Field Unit instrument, which has more than 3000 pixels on a 275 µm pitch, it is essential to address this problem in order to meet the energy-resolution requirements. The instrument’s energy-resolution budget requires that the impact of the thermal crosstalk on the energy resolution be a contribution that, added in quadrature to other energy-resolution contributions, is less than 0.2 eV. This value results in a derived requirement that the ratio between the amplitude of the crosstalk signal to an X-ray pulse (for example at 6 keV) is less than 1 × 10(exp −3) (for the first neighbor), less than 4 × 10(exp −4) (for the diagonal neighbor) and less than 8 × 10(exp −5) (for the second nearest neighbor). We have measured the thermal crosstalk levels between pixels in various geometries and configurations. The results show a crosstalk ratio which is at least a factor of 4 lower than the derived requirement. We also developed a finite element (FEM) 2D thermal model to predict the thermal behavior of large-scale arrays. This model successfully simulates the measured data in terms of pulse amplitude and time constants.

Antoine R. Miniussi↗

Optical Characterization of Laser Retroreflector Arrays for Lunar Landers

Laser Retroreflector Array for Lunar Landers (LRALL) is a small optical instrument designed to provide a target for precision laser ranging from a spacecraft in lunar orbit, enabling geolocation of the lander and its instrument suite and establishing a fiducial maker on the lunar surface. Here we describe the optical performance of LRALL at visible and near-infrared wavelengths. Individual corner cube reflectors (CCRs) within LRALL were tested for surface flatness and dihedral angle values. We also imaged the far-field diffraction patterns of individual CCRs as well as the entire retroreflector array over the range of possible incident angles to extract the optical cross section as a function of viewing angle. We also measured the optical properties of one of the CCRs over the lunar temperature range (100 K to 380 K) and found no significant temperature-dependent variance. The test results show LRALL meets the design criteria and can be ranged to from elevation angles above 30° with respect to the instrument base from an orbital laser altimeter such as the Lunar Orbiter Laser Altimeter (LOLA) on the Lunar Reconnaissance Orbiter (LRO). This work summarizes the test data and serves as a guide for future laser ranging to these retroreflector arrays.

Daniel R Cremons↗

Two-element optical array receiver concept demonstartion

The conceptual design, theoretical performance, and experimental verification of a two-telescope optical array receiver currently under development at the Jet Propulsion Laboratory, is described in this paper. A brief summary of optical communications theory for array reception of pulsed laser signals is developed, and the impact of coding discussed. The development of the optical detection, array processing, and data-acquisition assemblies required for experimental demonstration is described, and preliminary results obtained in a field environment are presented and evaluated.

Srinivasan, Meera↗

Design and Implementation of a Deep Space Communications Complex Downlink Array

This paper describes the design and implementation of a frequency domain beamformer that will downlink array the signals of up to eight 34-m or 70-m antennas at each of NASA’s three Deep Space Communications Complexes (DSCC). The array digitizes inputs with an Intermediate Frequency (IF) of 100 to 600 MHz, coherently combines the inputs digitally, and transforms the combined waveform back to analog. Real-time correlation measurements are used for delay and phase calibration, allowing the system to adjust for atmospheric variations. A DSCC Downlink Array system is operational at each DSCC. Initial results from passes with the New Horizons spacecraft are presented and system performance is analyzed.

Wang, Douglas↗

The International Pulsar Timing Array: Second Data Release

In this paper, we describe the International Pulsar Timing Array second data release, which includes recent pulsar timing data obtained by three regional consortia: the European Pulsar Timing Array, the North American Nanohertz Observatory for Gravitational Waves, and the Parkes Pulsar Timing Array. We analyse and where possible combine high-precision timing data for 65 millisecond pulsars which are regularly observed by these groups. A basic noise analysis, including the processes which are both correlated and uncorrelated in time, provides noise models and timing ephemerides for the pulsars. We find that the timing precisions of pulsars are generally improved compared to the previous data release, mainly due to the addition of new data in the combination. The main purpose of this work is to create the most up-to-date IPTA data release. These data are publicly available for searches for low-frequency gravitational waves and other pulsar science.

neutron↗

Modeling the Uncertainties of Solar System Ephemerides for Robust Gravitational-wave Searches with Pular-timing Arrays

The regularity of pulsar emissions becomes apparent once we reference the pulses’ times of arrivals to the inertial rest frame of the solar system. It follows that errors in the determination of Earthʼs position with respect to the solar system barycenter can appear as a time-correlated bias in pulsar-timing residual time series, affecting the searches for low-frequency gravitational waves performed with pulsar-timing arrays. Indeed, recent array data sets yield different gravitational-wave background upper limits and detection statistics when analyzed with different solar system ephemerides. Crucially, the ephemerides do not generally provide usable error representations. In this article, we describe the motivation, construction, and application of a physical model of solar system ephemeris uncertainties, which focuses on the degrees of freedom (Jupiterʼs orbital elements) most relevant to gravitational-wave searches with pulsar-timing arrays. This model, BAYESEPHEM, was used to derive ephemeris-robust results in NANOGravʼs 11 yr stochastic-background search, and it provides a foundation for future searches by NANOGrav and other consortia. The analysis and simulations reported here suggest that ephemeris modeling reduces the gravitational-wave sensitivity of the 11 yr data set and that this degeneracy will vanish with improved ephemerides and with pulsar-timing data sets that extend well beyond a single Jovian orbital period.

M Vallisneri↗

Atacama Compact Array Measurements of the Molecular Mass in the NGC 5044 Cooling-Flow Group

The fate of cooling gas in the centers of galaxy clusters and groups is still not well understood, as is also the case for the complex processes of triggering star formation in central dominant galaxies, reheating of cooled gas by active galactic nuclei (AGN), and the triggering or “feeding” of supermassive black hole outbursts. We present CO observations of the early-type galaxy NGC 5044, which resides at the center of an X-ray bright group with a moderate cooling flow. For our analysis we combine CO(2−1) data from the 7 m antennae of the Atacama Compact Array (ACA) and the ACA total power array (TP). We demonstrate, using the 7 m array data, that we can recover the total flux inferred from IRAM 30 m single-dish observations, which corresponds to a total molecular mass of about 4 × 10(exp 7) M⨀ Most of the recovered flux is blueshifted with respect to the galaxy rest frame and is extended on kiloparsec-scales, suggesting low filling factor dispersed clouds. We find eight concentrations of molecular gas out to a radius of 10” (1.5 kpc), which we identify with giant molecular clouds. The total molecular gas mass is more centrally concentrated than the X-ray emitting gas but is extended in the northeast-southwest direction beyond the IRAM 30 m beam. We also compare the spatial extent of the molecular gas to the Hα emission: The CO emission coincides with the very bright Hα region in the center. We do not detect CO emission in the fainter Hα regions. Furthermore, we find two CO absorption features spatially located at the center of the galaxy, within 5 pc projected distance of the AGN, infalling at 255 and 265 km s(exp −1) relative to the AGN. This indicates that the two giant molecular clouds seen in absorption are most likely within the sphere of influence of the supermassive black hole.

Galaxy clusters↗

Assembly and Integration Process of the High-Density Detector Array Readout Modules for the Simons Observatory

The Simons Observatory will measure the cosmic microwave background tempera-ture and polarization using a suite of new telescopes in the Atacama Desert in Chile. The Simons Observatory will use dichroic transition edge sensor (TES) bolometer arrays spanning six frequency bands from 27 to 280 GHz. The Simons Observa-tory will pioneer the use of a densely packed multiplexing architecture based on the microwave SQUID multiplexer ( 𝜇mux), housing ∼2000 microwave resonators, each coupled to a TES. The Simons Observatory aims to multiplex each array of ∼2000 detectors with a single pair of coaxial cables and requires a multiplexing factor of ∼1000 . The Simons Observatory cryogenic readout system is called the universal microwave multiplexing module (UMM). The UMM couples to both horn and lenslet-coupled detector arrays and is integrated into the universal focal-plane module (UFM) after being independently characterized. We present processes we have developed for highly repeatable and automated integration methods of UMMs, which will be needed for the production of the 49 UFMs required for the first stage of the Simons Observatory.

CMB↗