Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “annular”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Denoising atomic resolution 4D scanning transmission electron microscopy data with tensor singular value decomposition

Tensor singular value decomposition (SVD) is a method to find a low-dimensional representation of data with meaningful structure in three or more dimensions. Here, tensor SVD has been applied to denoise atomic-resolution 4D scanning transmission electron microscopy (4D STEM) data. On data simulated from a SrTiO 3 [100] perfect crystal and a Si [110] edge dislocation, tensor SVD achieved an average peak signal-to-noise ratio (PSNR) of ~40 dB, which matches or exceeds the performance of other denoising methods, with processing times at least 100 times shorter. On experimental data from SrTiO 3 [100] and LiZnSb [11 2 ¯ 0]/GaSb [110] samples, tensor SVD denoises multiple GB 4D STEM data sets in ten minutes on a typical personal computer. Denoising with tensor SVD improves both convergent beam electron diffraction patterns and virtual-aperture annular dark field images.

36 MATERIALS SCIENCE↗

Persistence and decontamination of surrogate radioisotopes in a model drinking water distribution system

Contamination of a model drinking water system with surrogate radioisotopes was examined with respect to persistence on and decontamination of infrastructure surfaces. Cesium and cobalt chloride salts were used as surrogates for cesium-137 and cobalt-60. Studies were conducted in biofilm annular reactors containing heavily corroded iron surfaces formed under shear and constantly submerged in drinking water. Cesium was not detected on the corroded iron surface after equilibration with 10 and 100 mg L{sup -1} solutions of cesium chloride, but cobalt was detected on corroded iron coupons at both initial concentrations. The amount of adhered cobalt decreased over the next six weeks, but was still present when monitoring stopped. X-ray absorption near-edge spectroscopy (XANES) showed that adhered cobalt was in the III oxidation state. The adsorbed cobalt was strongly resistant to decontamination by various physicochemical methods. Simulated flushing, use of free chlorine and dilute ammonia were found to be ineffective whereas use of aggressive methods like 14.5 M ammonia and 0.36 M sulfuric acid removed 37 and 92% of the sorbed cobalt, respectively.

54 ENVIRONMENTAL SCIENCES↗

Annihilation-gamma-based diagnostic techniques for magnetically confined electron–positron pair plasma

Efforts are underway to magnetically confine electron–positron pair plasmas to study their unique behaviour, which is characterized by significant changes in plasma time and length scales, supported waves and unstable modes. However, use of conventional plasma diagnostics presents challenges with these low-density and annihilating matter–antimatter plasmas. To address this problem, we propose to develop techniques based on the distinct emission provided by annihilation. This emission exhibits two spatial correlations: the distance attenuation of isotropic sources and the back-to-back propagation of momentum-preserving 2 $\gamma$ annihilation. We present the results of our analysis of the $\gamma$ emission rate and the spatial profile of the annihilation in a magnetized pair plasma from direct pair collisions, from the formation and decay of positronium as well as from transport processes. In order to demonstrate the effectiveness of annihilation-based techniques, we tested them on annular $\gamma$ emission profiles produced by a $\beta ^+$ radioisotope on a rotating turntable. Direct and positronium-mediated annihilation result in overlapping volumetric $\gamma$ sources, and the 2 $\gamma$ emission from these volumetric sources can be tomographically reconstructed from coincident counts in multiple detectors. Transport processes result in localized annihilation where field lines intersect walls, limiters or internal magnets. These localized sources can be identified by the fractional $\gamma$ counts on spatially distributed detectors.

Physics↗

Spatial Resolution and Information Transfer in Scanning Transmission Electron Microscopy

The relation between image resolution and information transfer is explored. It is shown that the existence of higher frequency transfer in the image is just a necessary but not sufficient condition for the achievement of higher resolution. Adopting a two-point resolution criterion, we suggest that a 10% contrast level between two features in an image should be used as a practical definition of resolution. In the context of scanning transmission electron microscopy, it is shown that the channeling effect does not have a direct connection with image resolution because sharp channeling peaks do not move with the scanning probe. Through a quantitative comparison between experimental image and simulation, a Fourier-space approach is proposed to estimate defocus and sample thickness. The effective atom size in Z-contrast imaging depends on the annular detector's inner angle. Therefore, an optimum angle exists for the highest resolution as a trade-off between reduced atom size and reduced signal with limited information transfer due to noise.

47 OTHER INSTRUMENTATION↗

Development of Protocols Suitable for Atomic-Scale Imaging of Catalyst Clusters at Catalytic Temperatures

Recent advances in aberration corrected electron microscopy (ACEM) are providing new tools and opportunities for studying chemical processes at gas-solid interfaces at atomic resolutions. In the area of heterogeneous catalysis, STEM-based high-angle annular dark-field imaging (HAADF) has provided the potential for direct observation of single heavy atoms and atom clusters. [1]. This approach has been used to study catalytic properties by directly probing structure development as a result of metal particle-substrate interactions, and used to explore the combined effects of temperature, promoters, and organic ligands on the evolution of catalyst structure [2- 3]. Associated with this new tool is the potential for artifacts, such as electron beam-induced polymerization of organic components [4], and the influence of the electron beam on heavy atom diffusion and nanostructuring [5]. Experiments were conducted in order to develop sample preparation techniques and imaging protocols that are suitable for achieving sub- ngstr m resolutions at ambient temperatures. In-situ heating studies were also conduct using AduroTM heater devices manufactured using MEMS technology by Protochips Inc. (Raleigh, NC) [6].

atomic-scale imaging↗

Imaging ZnO Nanobelts and Nanobelt-Supported Metal Nanocatalysts by Aberration-Corrected Scanning Transmission Electron Microscopy

The development of aberration correctors and their routine applications in transmission and scanning transmission electron microscopy mode have enabled sub- ngstr m imaging of practical nanoscale materials and nanocatalysts. To correctly interpret the observed image contrast of practical samples is, however, still challenging. For example, the contrast of the various features in a high-angle annular dark-field (HA-ADF) image can be affected by many parameters such as sample tilt [1], presence of amorphous materials [2], overlapping crystallites, electron-beam channeling, etc. The visibility and image contrast of individual monomers, dimers or small clusters supported on relatively thick crystalline substrates may be modulated by tilting the substrate crystal away from electron-beam channeling conditions or the major zone axes.

aberration-corrected↗

Surface Channeling in Aberration-Corrected Scanning Transmission Electron Microscopy of Nanostructures

Here, the aberration-corrected scanning transmission electron microscope can provide information on nanostructures with sub-Ångström image resolution. The relatively intuitive interpretation of high-angle annular dark-field (HAADF) imaging technique makes it a popular tool to image a variety of samples and finds broad applications to characterizing nanostructures, especially when combined with electron energy-loss spectroscopy and X-ray energy-dispersive spectroscopy techniques. To quantitatively interpret HAADF images, however, requires full understanding of the various types of signals that contribute to the HAADF image contrast. We have observed significant intensity enhancement in HAADF images, and large expansion of lattice spacings, of surface atoms of atomically flat ZnO surfaces. The surface-resonance channeling effect, one of the electron-beam channeling phenomena in crystalline nanostructures, was invoked to explain the observed image intensity enhancement. A better understanding of the effect of electron beam channeling along surfaces or interfaces on HAADF image contrast may have implications for quantifying HAADF images and may provide new routes to utilize the channeling phenomenon to study surface structures with sub-Ångström spatial resolution.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development of a Novel Environmental Cell for In-Situ Gas Reaction Experiments via Aberration-Corrected STEM Imaging

A novel heating technology composed of a disposable MEMS-based (microelectromechanical systems) device has recently been developed and shown to provide unique in-situ heating capabilities in electron microscopes [1]. Protochips, Inc. (Raleigh, NC) provides the AduroTM heater technology, composed of a disposable MEMS device that serves both as the heating element and the specimen support grid, a TEM holder with electrical feed-throughs, and an external current source. This system has been shown to provide near instantaneous (106 C/s) heating and cooling, and is stable to the limit of the microscope's specimen stage so full sub- ngstr m image resolution in highangle annular dark-field imaging mode can be achieved on our JEOL 2200FS scanning transmission electron microscope (STEM/TEM) instrument, fitted with a hexapole corrector on the probe-forming lenses (CEOS GmbH, Heidelberg, Ger.). This heating technology is being extended to function in a closed cell system that allows heating in a gaseous environment for in-situ elevated temperature reaction studies. The design concepts and early results of testing of the environmental cell (E-cell) performance are detailed here.

aberration-corrected↗

Compositional Analysis With Atomic Column Spatial Resolution by 5th Order Aberration-corrected Scanning Transmission Electron Microscopy

We show in this article that it is possible to obtain elemental compositional maps and profiles with atomic-column resolution across an In{sub x}Ga{sub 1-x}As multilayer structure from 5th-order aberration-corrected high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) images. The compositional profiles obtained from the analysis of HAADF-STEM images describe accurately the distribution of In in the studied multilayer in good agreement with Muraki's segregation model [Muraki, K., Fukatsu, S., Shiraki, Y. & Ito, R. (1992)]. Surface segregation of In atoms during molecular beam epitaxy and its influence on the energy levels in InGaAs/GaAs quantums wells.

36 MATERIALS SCIENCE↗

The three-dimensional point spread function of aberration-corrected scanning transmission electron microscopy

Aberration-correction reduces the depth of field in scanning transmission electron microscopy and allows three-dimensional imaging by depth-sectioning. This imaging mode offers the potential for sub- ngstrom lateral resolution and nanometer-scale depth sensitivity. For biological samples, which may be many microns across and where high lateral resolution may not always be needed, optimizing the depth resolution even at the expense of lateral resolution may be desired, aiming to image through thick specimens. Although there has been extensive work examining and optimizing the probe formation in two-dimensions, there is less known about the probe shape along the optical axis. Here we examine the probe shape in three-dimensions in an attempt to better understand the depth-resolution in this mode. We present examples of how aberrations change the probe shape in three-dimensions and demonstrate that off-axial aberrations may need to be considered for focal series of large areas. We show that oversized or annular apertures theoretically improve the vertical resolution for 3D imaging of nanoparticles. When imaging nanoparticles of several nanometer size, the regular STEM can thereby be optimized such that the vertical full width at half maximum approaches that of the aberration corrected STEM with a standard aperture.

99 GENERAL AND MISCELLANEOUS↗

Combined Scanning Transmission Electron Microscopy Tilt- and Focal Series

In this study, a combined tilt- and focal series is proposed as a new recording scheme for high-angle annular dark-field scanning transmission electron microscopy (STEM) tomography. Three-dimensional (3D) data were acquired by mechanically tilting the specimen, and recording a through-focal series at each tilt direction. The sample was a whole-mount macrophage cell with embedded gold nanoparticles. The tilt focal algebraic reconstruction technique (TF-ART) is introduced as a new algorithm to reconstruct tomograms from such combined tilt- and focal series. The feasibility of TF-ART was demonstrated by 3D reconstruction of the experimental 3D data. The results were compared with a conventional STEM tilt series of a similar sample. The combined tilt- and focal series led to smaller missing wedge artifacts, and a higher axial resolution than obtained for the STEM tilt series, thus improving on one of the main issues of tilt series-based electron tomography.

Dahmen, Tim↗

Advanced FIB-based Preparation of Cryogenically-prepared Specimens for APT Analysis

The utilization of the focused ion beam scanning electron microscope (FIB-SEM) has aided the application of Atom Probe Tomography (APT) to a continually-growing variety of materials, including soft biological materials. However, the regular application of APT to hydrated interfaces such as those found in biological and environmental materials is lacking in large part due to difficulties in specimen preparation under high and ultra-high vacuum conditions. Although a FIB-SEM based cryogenic specimen preparation approach offers a rational route to the preparation of such specimens for APT analysis, many practical aspects such as welding and limitations in the cryo stage manipulation makes it challenging for routine liftout of site-targeted specimens. In this work, we describe our recent efforts in the development of a site-specific liftout and attachment scheme for cryogenically cooled specimens involving a combination of redeposition and overcoating of organic and organometallic molecules, as shown in Fig. 1a-d for a cryogenically-frozen corroded glass sample containing a hydrated porous gel surface layer. Application of an annular milling pattern to the frozen specimens leads to a needle-shaped morphology necessary for APT analysis with the targeted water-ice filled porous corroded silicate glass region of interest near the apex. Using a custom shuttle device and environmental transfer hub at PNNL to facilitate environmentally-protected specimen transfer, APT analysis was applied to directly map, for the first time, a water/solid interface in 3D to reveal the complex nanoscale water-filled porous network of corroded glass. Application of this unique specimen preparation approach to biological specimens will also be discussed, as well as the application of a unique cryo nanomaniupulator with integrated gas injection system to enable controlled FIB-based welding under cryogenic temperatures.

59 BASIC BIOLOGICAL SCIENCES↗

Atomic Resolution Imaging of Light Elements in a Crystalline Environment using Dynamic Hollow-Cone Illumination Transmission Electron Microscopy

Multiple electron scattering and the nonintuitive nature of image formation with coherent radiation complicate the interpretation of conventional transmission electron microscopy images. Precession of the illuminating beam in transmission electron microscopy (TEM) can lead to more robust and interpretable images with some penalty to image contrast, a technique known as dynamic hollow-cone illumination TEM. Here, we demonstrate direct and robust imaging of light and heavy atoms in a crystalline environment with this technique. This method is similar to the annular bright-field technique in scanning transmission electron microscopy, via the principle of reciprocity. Dynamic hollow-cone illumination TEM is challenging in practice due to sensitivity to the misalignment of the precession axis, microscope objective aperture, and crystal zone axis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accessing Atomic-scale Phosphorus Dopant Distribution in Precise Silicon Devices by Advanced STEM Imaging and Spectroscopy

The structural and chemical characterization at the atomic-scale plays a critical role in understanding the structure-property relationship in precise electrical devices such as those produced by atomic-precision advanced manufacturing (APAM). APAM, utilizing hydrogen lithography in a scanning tunneling microscope, offers a potential pathway to ultra-efficient transistors, and has been developed to produce phosphorus (P)-based donor devices integrated into bare Si substrates. Structural characterization of the buried, Si with P dopant (Si:P) delta-layer in the devices by scanning transmission electron microscopy (STEM), however, is a challenge due to similar atomic number and low concentration of the P dopants. In this paper, we describe several efforts of utilizing advanced STEM imagining and spectroscopic techniques to quantify the Si:P deltalayers. STEM imaging combining low-angle and high-angle annular dark-field (LAADF, HAADF) detectors as well as atomic-scale elemental mapping using energy-dispersive X-ray spectroscopy (EDS) are used to reveal the P and defect distribution across the delta-layer processed under various thermal conditions.

47 OTHER INSTRUMENTATION↗

Synthesis and Electrical Properties of a New Compound (BiSe) 0.97 (Bi 2 Se 3 ) 1.26 (BiSe) 0.97 (MoSe 2 ) Containing Metallic 1T-MoSe 2

The synthesis and electrical properties of a new misfit compound containing BiSe, Bi 2 Se 3 , and MoSe 2 constituent layers are reported. The reaction pathway involves competition between the formation of (BiSe) 1+x (Bi 2 Se 3 ) 1+y (BiSe) 1+x (MoSe 2 ) and [(Bi 2 Se 3 ) 1+y ] 2 (MoSe 2 ). Excess Bi and Se are required in the precursor to synthesize (BiSe) 1+x (Bi 2 Se 3 ) 1+y (BiSe) 1+x (MoSe 2 ). High-angle annular dark field-scanning transmission electron microscopy (HAADF-STEM) confirm the stacking sequence of the heterostructure. Small grains of both 2H- and 1T-MoSe 2 are observed in the MoSe 2 layers. X-ray photoelectron spectroscopy (XPS) indicates that there is a significantly higher percentage of 1T-MoSe 2 in (BiSe) 1+x (Bi 2 Se 3 ) 1+y (BiSe) 1+x (MoSe 2 ) than in (BiSe) 0.97 (MoSe 2 ), suggesting that more charge transfer to MoSe 2 occurs due to the additional BiSe layer. The additional charge transfer results in (BiSe) 1+x (Bi 2 Se 3 ) 1+y (BiSe) 1+x (MoSe 2 ) having a low resistivity (14–19 μΩ m) with metallic temperature dependence. Furthermore, the heterogeneous mix of MoSe 2 polytypes observed in the XPS complicates the interpretation of the Hall data as two bands contribute to the electrical continuity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PbI 2 Nanocrystal Growth by Atomic Layer Deposition from Pb(tmhd) 2 and HI

Atomic layer deposition (ALD) allows for fine control over the thickness, stoichiometry, and structural defects of materials. ALD provides a suitable route to deposit lead halides, which can further be converted to perovskites for photovoltaics, photoemission, and photodetection, among other applications. Deposition of lead halides by ALD has already begun to be explored; however, the precursors used in published processes are highly hazardous, require expensive fabrication processes, or contain impurities that can jeopardize the optoelectronic properties of metal halide perovskites after conversion. In this work, we deposited lead iodide (PbI 2 ) by a facile ALD process involving only two readily accessible and low-cost precursors. PbI 2 nanocrystals were grown on soda-lime glass (SLG), silicon dioxide support grids, and silicon wafer substrates and provided the groundwork for further investigation into developing lead halide perovskite processes by ALD. Further, the ALD-grown PbI 2 was characterized by annular dark-field scanning transmission electron microscopy (ADF-STEM), atomic force microscopy (AFM), high resolution transmission electron microscopy (HRTEM), X-ray fluorescence (XRF), and X-ray photoemission spectroscopy (XPS), among other methods. This work presents the first step to synthesize lead halide perovskites with atomic control for applications such as interfacial layers in photovoltaics and for deposition in microcavities for lasing.

36 MATERIALS SCIENCE↗

Delineating the Roles of Mn, Al, and Co by Comparing Three Layered Oxide Cathodes with the Same Nickel Content of 70% for Lithium-Ion Batteries

High-nickel layered oxides continue to prevail in the energy storage market as the frontmost cathode candidates for next-generation lithium-ion batteries. Demand and development of LiNi 1–x–y Mn x Co y O 2 (NMC) and LiNi 1–x–y Co x Al y O 2 (NCA) cathodes are rampantly increasing, particularly for the electric vehicle (EV) industry. However, the continued presence of cobalt in NMC and NCA cathodes raises global concerns due to geopolitical and ethical issues attributed to Co sourcing. We herein introduce a novel cobalt-free, high-nickel cathode LiNi 0.7 Mn 0.25 Al 0.05 O 2 (NMA70) and benchmark it against Co-containing LiNi 0.7 Mn 0.15 Co 0.15 O 2 (NMC70) as well as Co- and Al-free LiNi 0.7 Mn 0.3 O 2 (NM70) cathodes with equivalent 70% Ni contents that are all synthesized in-house. NMA70 displays a high initial C/10 capacity of 210 mA h g –1 , matching that of NMC70 in half cells with a cutoff voltage of 4.5 V. NMA70 also exhibits an impressive high-voltage full cell cycling performance with a cutoff voltage of 4.4 V with a nearly identical capacity retention of 83% compared to that of 82% for NMC70 after 300 cycles. Postmortem X-ray photoelectron spectroscopy (XPS), high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM), and electron energy loss spectroscopy (EELS) analyses indicate a thinner cathode–electrolyte interface (CEI) developed in NMA70 compared to that in NM70 and unveil a more robust solid-electrolyte interface (SEI) passivation on the graphite anode among all samples. The benefits of Al doping are additionally highlighted with enhanced high-voltage CEI and thermal stabilities in NMA70. Furthermore, this work assesses the roles of Mn, Al, and Co to demonstrate both the practicality and feasibility of synthesizing cobalt-free, high-nickel cathodes that are promising alternatives to current NMC- and NCA-based cathodes.

25 ENERGY STORAGE↗

Thermal Stability of Quasi-1D NbS 3 Nanoribbons and Their Transformation to 2D NbS 2 : Insights from in Situ Electron Microscopy and Spectroscopy

Here in situ electron microscopy imaging and spectroscopy enabled us to study the evolution of quasi-1D NbS 3 -IV nanoribbons with respect to morphology and chemical structure at temperatures between room temperature and 1000 °C. Scanning transmission electron microscopy (STEM) experiments included imaging in the secondary electron, (transmitted) bright field, and high-angle annular dark-field modes while operating in the low kV regime. The results showed that NbS 3 -IV samples transform dramatically from smooth nanoribbons into highly textured configurations featuring polyhedral divots and steps. Similar in situ heating experiments conducted with aberration-corrected STEM revealed that bilayers of NbS 3 -IV chains convert topotactically into aligned 2H-NbS 2 sheets upon loss of sulfur. Atomic resolution imaging, fast Fourier transform analysis, and electron energy loss spectroscopy confirmed these chemical changes, from which we propose an atomistic mechanism for the NbS 3 -IV → 2H-NbS 2 conversion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗