Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Storage System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Arbitrage and Capacity Firming in Coordination with Day-Ahead Bidding of a Hybrid PV Plant: Preprint

A hybrid PV plant (HPP) combines a photovoltaic (PV) plant with a battery energy storage system (BESS), which is considered a promising step towards the future of renewable power plants by the U.S. Department of Energy. When the renewable penetration reaches a significant level, a hybrid PV plant can bid in as a controllable thermal plant in the future electricity market. In this study, a bidding and BESS scheduling model is proposed for the HPP. The robust optimization (RO) technique has been utilized to identify the worst-case scenario of uncertainties during the bidding process. To address the overly conservative issue of the single-stage RO, we have decoupled the BESS schedule for arbitrage and PV capacity firming by a two-stage RO formulation. By comparing the output of single-stage RO and two-stage RO, the two-stage RO bids and schedules in a more aggressive manner, which increases the income of HPP. Also, the penalty of under-generation is considered in our model so that the day-ahead bidding decision and arbitrage schedules can be adjusted based on the potential UNDER-GENERATION penalty. Because the proposed model is non-convex and contains multi-stages, the Column-and-Constraint Generation (C&CG) algorithm is applied to the model as the solution. The proposed model has shown better economic performance compared to a state-of-art single-stage bidding method in case studies.

BESS scheduling↗

A Technical and Economic Assessment of LWR Flexible Operation for Generation and Demand Balancing to Optimize Plant Revenue

With increased penetration of subsidized variable renewable energy (VRE) resources and competition from low natural gas prices, existing light water reactor (LWR) nuclear power plants (NPPs) are struggling to remain economically competitive. This work examines the potential economic competitiveness of various thermal energy storage (TES) technologies when coupled directly or indirectly with a NPP. To highlight their relative economic competitiveness, we contrast several energy storage solutions in stochastic dispatch optimization. We leverage data from recent work analyzing a range of TES technologies with varying capital costs, performance, and technology readiness level (TRL) to establish our case. We explore inserting these technologies into an electricity market with existing nuclear generation and large projected variable renewable energy (VRE) penetration. Although these technologies' projected capital costs may make them unlikely candidates in their current state, this analysis demonstrates a high-fidelity techno-economic analysis of energy storage. Furthermore, as the projected cost of energy storage technologies evolves, this analysis sets a precedent for similar future investigations. One region with projected trends that may be unfavorable for existing nuclear capacity is the New York Independent System Operator (NYISO) market. New York state’s baseload generation has been historically provided by fossil-fired and nuclear assets. However, amid economic pressures from subsidized VREs and low natural gas prices, the state has recently deactivated Indian Point nuclear power plant units 2 and 3. Furthermore, the state plans to meet its zero-emission generation target by 2040 by replacing fossil-fired capacity with significant investments in VRE resources like wind and solar photovoltaic (PV) and battery storage. Increased intermittent resource penetration lowers the baseload power requirement, adding further economic pressure to the state’s three remaining NPPs still in operation. With three NPPs still in operation in New York, this work analyzes potential economic benefits to NPPs on the New York grid when directly or indirectly coupled with various TES technologies. This work requires two modeling steps to analyze the potential economic benefits of various system configurations of the TES directly or indirectly coupled with nuclear. First, this analysis leverages capacity expansion modeling by experts at the Electric Power Research Institute (EPRI). Using their deterministic capacity expansion model, U.S. Regional Economy, Greenhouse Gas, and Energy (US-REGEN), EPRI analysts evaluated the capacity and generation evolution of the New York state energy market under four projection scenarios. These four projection scenarios were developed to represent the potential evolution of the capacity and generation in NYISO from 2015 to 2050 under various economic, technology, and policy constraints. The results from these capacity expansion models are then used as boundary conditions in the second modeling step. The second modeling step uses the Holistic Energy Resource Optimization Network (HERON) for a set of stochastic techno-economic analyses (STEAs) to investigate the potential increase in the economic viability of various configurations of the TES. With no current capacity expansion capabilities, HERON takes the data generated from US-REGEN for 2050 to generate synthetic load, solar, and wind data. Then HERON economically optimizes the capacity and dispatch of the various TES configurations. The potential economic benefit is the differential net present value (NPV) of the TES configurations from the no-TES baseline. As a stochastic techno-economic analysis package, HERON introduces uncertainty into the economic metrics, while US-REGEN trades resolution for reduced computational complexity. Using HERON also allows the modeling of direct thermal coupling, a feature not common in capacity and dispatch models. As expected, with high capital costs, the costs of introducing energy storage for all the technologies considered outweighed the potential economic benefit of this strategy for flexible plant operation. The benefit of this analysis is primarily in demonstrating a workflow that examines innovative solutions to increase NPP revenue via TES coupling. HERON’s stochastic capacity and dispatch optimization process used in this work has proven an effective tool in observing and evaluating the impact of introducing storage technologies in a grid energy system.

25 ENERGY STORAGE↗

Integral Radiator and Storage Tank

A simplified, lightweight system for dissipating heat of a regenerative fuel- cell system would include a heat pipe with its evaporator end placed at the heat source and its condenser end integrated into the wall of the regenerative fuel cell system gas-storage tanks. The tank walls act as heat-radiating surfaces for cooling the regenerative fuel cell system. The system was conceived for use in outer space, where radiation is the only physical mechanism available for transferring heat to the environment. The system could also be adapted for use on propellant tanks or other large-surface-area structures to convert them to space heat-radiating structures. Typically for a regenerative fuel cell system, the radiator is separate from the gas-storage tanks. By using each tank s surface as a heat-radiating surface, the need for a separate, potentially massive radiator structure is eliminated. In addition to the mass savings, overall volume is reduced because a more compact packaging scheme is possible. The underlying tank wall structure provides ample support for heat pipes that help to distribute the heat over the entire tank surface. The heat pipes are attached to the outer surface of each gas-storage tank by use of a high-thermal conductance, carbon-fiber composite-material wrap. Through proper choice of the composite layup, it is possible to exploit the high longitudinal conductivity of the carbon fibers (greater than the thermal conductivity of copper) to minimize the unevenness of the temperature distribution over the tank surface, thereby helping to maximize the overall heat-transfer efficiency. In a prototype of the system, the heat pipe and the composite wrap contribute an average mass of 340 g/sq m of radiator area. Lightweight space radiator panels have a mass of about 3,000 g/sq m of radiator area, so this technique saves almost 90 percent of the mass of separate radiator panels. In tests, the modified surface of the tank was found to have an emissivity of 0.85. The composite wrap remained tightly bound to the surface of the tank throughout the testing in thermal vacuum conditions.

Burke, Kenneth A.↗

Evaluation of Polymer Hermetically Sealed Tantalum Capacitors

Polymer cathode tantalum capacitors have lower ESR (equivalent series resistance) compared to other types of tantalum capacitors and for this reason have gained popularity in the electronics design community. Their use allows improved performance of power supply systems along with substantial reduction of size and weight of the components used. However, these parts have poor thermal stability and can degrade in humid environments. Polymer hermetically sealed (PHS) capacitors avoid problems related to environmental degradation of molded case parts and can potentially replace current wet and solid hermetically sealed capacitors. In this work, PHS capacitors manufactured per DLA LAM DWG#13030 are evaluated for space applications. Several lots of capacitors manufactured over period from 2010 to 2014 were tested for the consistency of performance, electrical and thermal characteristics, highly accelerated life testing, and robustness under reverse bias and random vibration conditions. Special attention was given to analysis of leakage currents and the effect of long-term high temperature storage on capacitors in as is condition and after hermeticity loss. The results show that PHS capacitors might be especially effective for low-temperature applications or for system requiring a cold start-up. Additional screening and qualification testing have been recommended to assure the necessary quality of capacitors for space projects.

ferrite beads↗

Enhancement of conventional concrete mix designs for sensible thermal energy storage applications

The study examines twenty-nine different concrete mix designs with varying constituents to improve thermal performance for energy storage at elevated temperatures up to 420 °C. Effects of variables including the type and volumetric percentage of coarse and fine aggregates, the type and replacement content of supplemental cementitious materials, water-to-cement ratio, the type and quantity of steel fiber reinforcement, and the inclusion of iron oxide powder are experimentally investigated by measuring the mechanical and thermal properties of each mix, with the overall goal of enhancing thermal performance and mitigating mechanical degradation for thermal energy storage (TES) applications. It is found that the use of siliceous aggregate with a high volumetric percentage produces the highest improvement (23 %–37 % at elevated temperatures) of concrete thermal conductivity, while silica fume replacement of Type I cement provides the highest improvement (4 %–8 % at elevated temperatures) of concrete specific heat. To simulate the operation of a TES system, thermal cycling was conducted to examine the change in concrete properties as a function of repetitive heating (during and after 50 total cycles to 420 °C). Based on the results of testing, concrete mix designs with high aggregate percentages (up to 72 % by volume), siliceous coarse aggregate, silica fume replacement of Type I cement (15 % by weight), and steel fiber reinforcement (up to 2 % by volume) facilitate enhanced TES performance by providing consistent thermal conductivity of ~2.2 W/m·K and specific heat of ~3.2 MJ/m 3 ·K under cyclic high temperature exposure.

25 ENERGY STORAGE↗

Room‐Temperature Formate Ester Transfer Hydrogenation Enables an Electrochemical/Thermal Organometallic Cascade for Methanol Synthesis from CO 2

Abstract The reduction of CO 2 to synthetic fuels is a valuable strategy for energy storage. However, the formation of energy‐dense liquid fuels such as methanol remains rare, particularly under low‐temperature and low‐pressure conditions that can be coupled to renewable electricity sources via electrochemistry. Here, a multicatalyst system pairing an electrocatalyst with a thermal organometallic catalyst is introduced, which enables the reduction of CO 2 to methanol at ambient temperature and pressure. The cascade methanol synthesis proceeds via CO 2 reduction to formate by electrocatalyst [Cp*Ir(bpy)Cl] + (Cp*=pentamethylcyclopentadienyl, bpy=2,2′‐bipyridine), Fischer esterification of formate to isopropyl formate catalyzed by trifluoromethanesulfonic acid (HOTf), and thermal transfer hydrogenation of isopropyl formate to methanol facilitated by the organometallic catalyst (H‐PNP)Ir(H) 3 (H‐PNP=HN(C 2 H 4 P i Pr 2 ) 2 ). The isopropanol solvent plays several crucial roles: activating formate ion as isopropyl formate, donating hydrogen for the reduction of formate ester to methanol via transfer hydrogenation, and lowering the barrier for transfer hydrogenation through hydrogen bonding interactions. In addition to reporting a method for room‐temperature reduction of challenging ester substrates, this work provides a prototype for pairing electrochemical and thermal organometallic reactions that will guide the design and development of multicatalyst cascades.

Fernández, Sergio [Department of Chemistry Univers↗

Self-Heating Conductive Ceramic Composites for High Temperature Thermal Energy Storage

The absence of affordable and deployable large-scale energy storage poses a major barrier to providing zero-emission energy on demand for societal decarbonization. High temperature thermal energy storage is one promising option with low cost and high scalability, but it is hindered by the inherent complexity of simultaneously satisfying all of the material requirements. Here we design a class of ceramic–carbon composites based on co-optimizing mechanical, electrical, and thermal properties. Further, these composites demonstrate stability in soak-and-hold tests and direct self-heating up to 1,936 °C and 750 thermal cycles from 500 to 1,630 °C without degradation. This thermal performance derives from their composition and microstructural design as verified by in situ high-temperature transmission electron microscopy and X-ray diffraction. They offer both higher energy density and lower cost than conventional storage technologies with a projected system Levelized Cost of Storage below the U.S. Department of Energy’s 2030 target 5 ¢/kWh (electric).

25 ENERGY STORAGE↗

Principles to adapt financing mechanisms for fully integrated hybrid energy systems

As the electricity sector evolves, and as all energy types (thermal, electric, chemical, etc.) become more coupled, there has been increased interest to develop and deploy hybrid energy systems (HES). This work focuses on fully integrated HES, where there are multiple energy sources and multiple energy products, often coupled through a storage buffer. A significant amount of the available literature on this work describes technology pathways for fully integrated HES; however, it is unclear how financial institutions should treat these systems. Fully integrated HES represent an increase in complexity from their stand-alone counterparts, but they also potentially mitigate financial risk and provide value to the energy system, which has not yet been accounted for in financing mechanisms that could help to enable such systems. This paper provides some examples of fully integrated HES and proposes principles to help adapt financing to adequately capture the value of such systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimizing Grid-interactive Efficient Building Designs with Stacked Value Streams

Grid-interactive efficient buildings (GEBs) are those characterized by the combination of energy efficiency and demand flexibility with smart technologies and communications to not only deliver greater affordability and comfort to buildings, but also help utilities manage grid operations and lower system costs. This paper presents an innovative techno-economic assessment framework to effectively examine different GEB design options, explore various use cases, define technically achievable benefits, and thereby assist in informed decision-making. In particular, building load flexibility, thermal storage, and battery energy storage are considered. Advanced optimal dispatch problem is formulated to maximize the stacked value streams from multiple, competing use cases, subject to the physical capabilities and operational flexibility associated with different designs and configurations. Comprehensive case studies were performed for a real-world building to evaluate the cost-effectiveness of different GEB designs and offer in-depth insights. It was found that the proposed assessment method could effectively capture the costs and benefits linked to each GEB design option. Furthermore, the study revealed that outage mitigation and demand response are the two most significant sources of benefits for GEBs.

Ma, Xu↗

Frequency Control and Dynamics (Part 1) [Slides]

This presentation provides an introductory overview of system dynamics and frequency control in electric power systems, with a focus on concepts relevant to small and interconnected grids such as those in Malawi. It explains foundational principles of AC system frequency, the relationship between generation-demand balance and frequency deviations, and the operational limits of generators and end-use equipment. The deck discusses frequency stability within broader system stability classifications and illustrates how inertia and turbine-governor dynamics shape system response to disturbances. It then outlines the tiered approach to frequency control - primary, secondary, and tertiary - detailing the roles, characteristics, timescales, and response mechanisms of each. Special emphasis is placed on hydro and thermal unit behavior, area control error (ACE), automatic generation control (AGC), and the operational implications of interconnecting small systems with larger grids. The material was developed to support Malawi's electricity sector and the establishment of the Southern Africa Battery Energy Storage Center of Excellence (SABESS CoE).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Control and Dynamics (Part 2) [Slides]

This presentation provides an introductory overview of system dynamics and frequency control in electric power systems, with a focus on concepts relevant to small and interconnected grids such as those in Malawi. It explains foundational principles of AC system frequency, the relationship between generation-demand balance and frequency deviations, and the operational limits of generators and end-use equipment. The deck discusses frequency stability within broader system stability classifications and illustrates how inertia and turbine-governor dynamics shape system response to disturbances. It then outlines the tiered approach to frequency control - primary, secondary, and tertiary - detailing the roles, characteristics, timescales, and response mechanisms of each. Special emphasis is placed on hydro and thermal unit behavior, area control error (ACE), automatic generation control (AGC), and the operational implications of interconnecting small systems with larger grids. The material was developed to support Malawi's electricity sector and the establishment of the Southern Africa Battery Energy Storage Center of Excellence (SABESS CoE).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Propellant thermal stratification

The term thermal stratification is used to express nonuniform heat distribution within the bulk propellant. The nonuniform distribution of heat results in significant temperature variations in booster propulsion propellants and causes an undesirable increase in the self-pressurization rate of cryogen storage systems. A semiempirical prediction method has been developed for high gravity environments and is adequate for design purposes; model accuracy is somewhat limited to similarity in tank geometries, and additional work is needed to extend the correlation range. Several low gravity environment models that cover a broad range of predicted results have been developed. There are no applicable data by which any of these models may be selected in preference over the others.

Winstead, T. W.↗

ATS-6 - Flight performance of the Advanced Thermal Control Flight Experiment

The Advanced Thermal Control Flight Experiment on ATS-6 was designed to demonstrate the thermal control capability of a thermal diode (one-way) heat pipe, a phase-change material for thermal storage, and a feedback-controlled heat pipe. Flight data for the different operational modes are compared to ground test data, and the performance of the components is evaluated on an individual basis and as an integrated temperature-control system.

Kirkpatrick, J. P.↗

Solar heating, cooling, and hot water systems installed at Richland, Washington

The project described is part of the U. S. Department of Energy's solar demonstration program, and became operational in April 1978. The solar system uses 6,000 square feet of flat-plate liquid collectors in a closed loop to deliver solar energy through a liquid-liquid heat exchanger to the building heat-pump duct work or 9,000-gallon thermal energy storage tank. A 25-ton Arkla solar-driven absorption chiller provides the cooling, in conjunction with a 2,000 gallon chilled water storage tank and reflective ponds on three sides of the building surplus heat. A near-by building is essentially identical except for having conventional heat-pump heating and cooling, and can serve as an experimental control. An on-going public relations program was provided from the beginning of the program, and resulted in numerous visitors and tour groups.

Source record↗

Solar thermal propulsion for planetary spacecraft

Previous studies have shown that many desirable planetary exploration missions require large injection delta-V. Solar Thermal Rocket (STR) propulsion, under study for orbit-raising applications may enhance or enable such high-energy missions. The required technology of thermal control for liquid hydrogen propellant is available for the required storage duration. Self-deploying, inflatable solar concentrators are under study. The mass penalty for passive cryogenic thermal control, liquid hydrogen tanks and solar concentrators does not compromise the specific impulse advantage afforded by the STR as compared to chemical propulsion systems. An STR injection module is characterized and performance is evaluated by comparison to electric propulsion options for the Saturn Orbiter Titan Probe (SOTP) and Uranus Flyby Uranus Probe (UFUP) missions.

Sercel, J. C.↗

The Space Infrared Telescope Facility structural design requirements

An effort is currently being carried out by the Jet Propulsion Laboratory (JPL) to study mission feasibility and to define functional requirements for various subsystems of the Space Infrared Telescope Facility (SIRTF). As a major part of this effort, structural design requirements have been derived based on the stated mission objectives. Design concerns addressed by these requirements include the limits on mass and location of the center of gravity, launch stiffness and dynamic characteristics, design loads and analysis criteria, survivability of the TITAN IV/Centaur launch environment, thermal control for maintaining a near absolute-zero operating temperature, and helium cryogen volume and storage for a five-year mission. To illustrate how the structural design requirements can be met, a point design of the SIRTF flight hardware system was developed, modeled, and analyzed. A description of the key features of this point design, along with pertinent modeling and analysis results, are discussed in this Paper.

Macneal, Paul D.↗

Effects of Hybridization on Selective Catalytic Reduction (SCR) Thermal Management of a Medium Heavy-Duty Hybrid Work Truck

The increased market penetration of hybrid electric powertrains in medium heavy-duty (MHD) applications has provided a novel platform for vehicle research. One example of such a platform is the MHD parallel hybrid truck developed by Odyne Systems, LLC. In collaboration with Odyne Systems, LLC and the Department of Energy (DOE), Oak Ridge National Laboratory (ORNL) developed a validated vehicle plant model for this truck and tested the Odyne powertrain in a hardware-in-the-loop (HIL) environment. While testing in the HIL environment, the effects of reduced engine load, and thus catalyst heating, on the selective catalytic reduction (SCR) catalyst produced diminished hybrid improvement as the level of energy storage usage increased. This article will discuss these results and the potentially unforeseen interactions with modern aftertreatment systems when hybridizing conventional powertrains.

33 ADVANCED PROPULSION SYSTEMS↗

The MIST /MIUS Integration and Subsystems Test/ laboratory - A testbed for the MIUS /Modular Integrated Utility System/ program

The MIUS (Modular Integrated Utility System) concept is to be an energy-conserving, economically feasible, integrated community utility system to provide five necessary services: electricity generation, space heating and air conditioning, solid waste processing, liquid waste processing, and residential water purification. The MIST (MIUS Integration and Subsystem Test) integrated system testbed constructed at the Johnson Space Center in Houston includes subsystems for power generation, heating, ventilation, and air conditioning (HVAC), wastewater management, solid waste management, and control and monitoring. The key design issues under study include thermal integration and distribution techniques, thermal storage, integration of subsystems controls and displays, incinerator performance, effluent characteristics, and odor control.

Beckham, W. S., Jr.↗