Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

AR/D image processing system

General Dynamics has developed advanced hardware, software, and algorithms for use with the Tomahawk cruise missile and other unmanned vehicles. We have applied this technology to the problem of locating and determining the orientation of the docking port of a target vehicle with respect to an approaching spacecraft. The system described in this presentation utilizes a multi-processor based computer to digitize and process television imagery and extract parameters such as range to the target vehicle, approach, velocity, and pitch and yaw angles. The processor is based on the Inmos T-800 Transputer and is configured as a loosely coupled array. Each processor operates asynchronously and has its own local memory. This allows additional processors to be easily added if additional processing power is required for more complex tasks. Total system throughput is approximately 100 MIPS (scalar) and 60 MFLOPS and can be expanded as desired. The algorithm implemented on the system uses a unique adaptive thresholding technique to locate the target vehicle and determine the approximate position of the docking port. A target pattern surrounding the port is than analyzed in the imagery to determine the range and orientation of the target. This information is passed to an autopilot which uses it to perform course and speed corrections. Future upgrades to the processor are described which will enhance its capabilities for a variety of missions.

Wookey, Cathy↗

Composition variations in pulsed-laser-deposited Y-Ba-Cu-O thin films as a function of deposition parameters

The composition of pulsed-ultraviolet-laser-deposited Y-Ba-Cu-O films was examined as a function of position across the substrate, laser fluence, laser spot size, substrate temperature, target conditioning, oxygen pressure and target-substrate distance. Laser fluence, laser spot size, and substrate temperature were found to have little effect on composition within the range investigated. Ablation from a fresh target surface results in films enriched in copper and barium, both of which decrease in concentration until a steady state condition is achieved. Oxygen pressure and target-substrate distance have a significant effect on film composition. In vacuum, copper and barium are slightly concentrated at the center of deposition. With the introduction of an oxygen background pressure, scattering results in copper and barium depletion in the deposition center, an effect which increases with increasing target-substrate distance. A balancing of these two effects results in stoichiometric deposition.

Foote, M. C.↗

The star identification, pointing and tracking system of UVSTAR, an attached payload instrument system for the Shuttle Hitchhiker-M platform

We describe an algorithm for star identification and pointing/tracking of a spaceborne electro-optical system and simulation analyses to test the algorithm. The algorithm will be implemented in the guiding system of UVSTAR, a spectrographic telescope for observations of astronomical and planetary sources operating in the 500-1250 A waveband at approximately 1 A resolution. The experiment is an attached payload and will fly as a Hitchhiker-M payload on the Shuttle. UVSTAR includes capabilities for independent target acquisition and tracking. The spectrograph package has internal gimbals that allow angular movement of plus or minus 3 deg from the central position. Rotation about the azimuth axis (parallel to the Shuttle z axis) and elevation axis (parallel to the Shuttle x axis) will actively position the field of view to center the target of interest in the fields of the spectrographs. The algorithm is based on an on-board catalog of stars. To identify star fields, the algorithm compares the positions of stars recorded by the guiding imager to positions computed from the on-board catalog. When the field has been identified, its position within the guiding imager field of view can be used to compute the pointing corrections necessary to point to a target of interest. In tracking mode, the software uses the past history to predict the quasi-periodic attitude control motions of the shuttle and sends pointing commands to cancel the motion and stabilize UVSTAR on the target. The guiding imager (guider) will have an 80-mm focal length and f/1.4 optics giving a field of view of 6 deg x 4.5 deg using a 385 x 288 pixel intensified CCD. It will be capable of providing high accuracy (better than 2 arc-sec) attitude determination from coarse (6 deg x 4.5 deg) initial knowledge of the pointing direction; and of pointing toward the target. It will also be capable of tracking at the same high accuracy with a processing time of less than a few hundredths of a second.

Decarlo, Francesco↗

Orbital docking system centerline color television camera system test

A series of tests was run to verify that the design of the centerline color television camera (CTVC) system is adequate optically for the STS-71 Space Shuttle Orbiter docking mission with the Mir space station. In each test, a mockup of the Mir consisting of hatch, docking mechanism, and docking target was positioned above the Johnson Space Center's full fuselage trainer, which simulated the Orbiter with a mockup of the external airlock and docking adapter. Test subjects viewed the docking target through the CTVC under 30 different lighting conditions and evaluated target resolution, field of view, light levels, light placement, and methods of target alignment. Test results indicate that the proposed design will provide adequate visibility through the centerline camera for a successful docking, even with a reasonable number of light failures. It is recommended that the flight deck crew have individual switching capability for docking lights to provide maximum shadow management and that centerline lights be retained to deal with light failures and user preferences. Procedures for light management should be developed and target alignment aids should be selected during simulated docking runs.

Mongan, Philip T.↗

Method for ambiguity resolution in range-Doppler measurements

A method for resolving range and Doppler target ambiguities when the target has substantial range or has a high relative velocity in which a first signal is generated and a second signal is also generated which is coherent with the first signal but at a slightly different frequency such that there exists a difference in frequency between these two signals of Delta f(sub t). The first and second signals are converted into a dual-frequency pulsed signal, amplified, and the dual-frequency pulsed signal is transmitted towards a target. A reflected dual-frequency signal is received from the target, amplified, and changed to an intermediate dual-frequency signal. The intermediate dual-frequency signal is amplified, with extracting of a shifted difference frequency Delta f(sub r) from the amplified intermediate dual-frequency signal done by a nonlinear detector. The final step is generating two quadrature signals from the difference frequency Delta f(sub t) and the shifted difference frequency Delta f(sub r) and processing the two quadrature signals to determine range and Doppler information of the target.

Heymsfield, Gerald M.↗

Preliminary design for a reverse Brayton cycle cryogenic cooler

A long life, single stage, reverse Brayton cycle cryogenic cooler is being developed for applications in space. The system is designed to provide 5 W of cooling at a temperature of 65 Kelvin with a total cycle input power of less than 200 watts. Key features of the approach include high speed, miniature turbomachines; an all metal, high performance, compact heat exchanger; and a simple, high frequency, three phase motor drive. In Phase 1, a preliminary design of the system was performed. Analyses and trade studies were used to establish the thermodynamic performance of the system and the performance specifications for individual components. Key mechanical features for components were defined and assembly layouts for the components and the system were prepared. Critical materials and processes were identified. Component and brassboard system level tests were conducted at cryogenic temperatures. The system met the cooling requirement of 5 W at 65 K. The system was also operated over a range of cooling loads from 0.5 W at 37 K to 10 W at 65 K. Input power to the system was higher than target values. The heat exchanger and inverter met or exceeded their respective performance targets. The compresssor/motor assembly was marginally below its performance target. The turboexpander met its aerodynamic efficiency target, but overall performance was below target because of excessive heat leak. The heat leak will be reduced to an acceptable value in the engineering model. The results of Phase 1 indicate that the 200 watt input power requirement can be met with state-of-the-art technology in a system which has very flexible integration requirements and negligible vibration levels.

Swift, Walter L.↗

LET spectra of fragmented 600-MeV/A iron beam on aluminum and polyethylene: A preliminary analysis

An iron beam experiment recently conducted at the Lawrence Berkeley Laboratory Bevalac by Benton et al. provides an opportunity for verifying the new Green's function computer code (GRNTRN) and assessing the related nuclear database. The iron beam with 600 MeV/A at extraction traversed a series of beam transport elements, lead foil, and several triggering devices before impacting the target. Of these, only the 2.24 g/sq cm lead foil and target are considered in the transport analysis with an assumed (inferred from calibration) beam energy of 557 MeV/A. A thin layer of CR-39 plastic nuclear track detector (PNTD) was placed in front of the target to monitor the incident flux and a stack of four PNTD's placed behind to measure the linear energy transfer (LET) distribution of the transported beam. Test data are analyzed for three separate targets: 2 g/sq cm aluminum, 5-cm polyethylene, and 8-cm polyethylene. The two-layer GRNTRN results were mapped into the detector response function for comparison with the measured LET spectra. Reasonable agreement is obtained. Future research and analysis can be improved by using a more accurate isotope set or including other important media which significantly alter the beam. The assumption that the fragmentation cross sections are too small for aluminum is inconclusive because the production of fragments by 2 g/sq cm aluminum can be more significantly affected by the fragment contribution originating from the media in front of the target than that currently considered in the analysis.

Shinn, Judy L.↗

AVIRIS calibration using the cloud-shadow method

More than 90 percent of the signal at an ocean-viewing, satellite sensor is due to the atmosphere, so a 5 percent sensor-calibration error viewing a target that contributes but 10 percent of the signal received at the sensor may result in a target-reflectance error of more than 50 percent. Since prelaunch calibration accuracies of 5 percent are typical of space-sensor requirements, recalibration of the sensor using ground-base methods is required for low-signal target. Known target reflectance or water-leaving radiance spectra and atmospheric correction parameters are required. In this article we describe an atmospheric-correction method that uses cloud shadowed pixels in combination with pixels in a neighborhood region of similar optical properties to remove atmospheric effects from ocean scenes. These neighboring pixels can then be used as known reflectance targets for validation of the sensor calibration and atmospheric correction. The method uses the difference between water-leaving radiance values for these two regions. This allows nearly identical optical contributions to the two signals (e.g., path radiance and Fresnel-reflected skylight) to be removed, leaving mostly solar photons backscattered from beneath the sea to dominate the residual signal. Normalization by incident solar irradiance reaching the sea surface provides the remote-sensing reflectance of the ocean at the location of the neighbor region.

Carder, K. L.↗

Triangulation methods for automated docking

An automated docking system must have a reliable method for determining range and orientation of the passive (target) vehicle with respect to the active vehicle. This method must also provide accurate information on the rates of change of range to and orientation of the passive vehicle. The method must be accurate within required tolerances and capable of operating in real time. The method being developed at Marshall Space Flight Center employs a single TV camera, a laser illumination system and a target consisting, in its minimal configuration, of three retro-reflectors. Two of the retro-reflectors are mounted flush to the same surface, with the third retro-reflector mounted to a post fixed midway between the other two and jutting at a right angle from the surface. For redundancy, two additional retroreflectors are mounted on the surface on a line at right angles to the line containing the first two retro-reflectors, and equally spaced on either side of the post. The target vehicle will contain a large target for initial acquisition and several smaller targets for close range.

Bales, John W.↗

Isotopic Enrichment of Boron in the Sputtering of Boron Nitride with Xenon Ions

An experimental study is described to measure the isotopic enrichment of boron. Xenon ions from 100 eV to 1.5 keV were used to sputter a boron nitride target. An ion gun was used to generate the ion beam. The ion current density at the target surface was approximately 30 microA/sq cm. Xenon ions impinged on the target surface at 50 deg angle to the surface normal. Since boron nitride is an insulator, a flood electron gun was used in our experiments to neutralize the positive charge buildup on the target surface. The sputtered secondary ions of boron were detected by a quadrupole mass spectrometer. The spectrometer entrance aperture was located perpendicular to the ion beam direction and 10 mm away from the target surface. The secondary ion flux was observed to be enriched in the heavy isotopes at lower ion energies. The proportion of heavy isotopes in the sputtered secondary ion flux was found to decrease with increasing primary ion energy from 100 to 350 eV. Beyond 350 eV, light isotopes were sputtered preferentially. The light isotope enrichment factor was observed to reach an asymptotic value of 1.27 at 1.5 keV. This trend is similar to that of the isotopic enrichment observed earlier when copper was sputtered with xenon ions in the same energy range.

Ray, P. K.↗

The Video Guidance Sensor- A Flight Proven Technology

The Video Guidance Sensor (VGS) flew on Shuttle mission STS-95 in October of 1998 to test the VGS functional characteristics on orbit. This was the second flight of the VGS, and during these two flights, both long range and short range data were gathered under a variety of lighting conditions, orbital exposure times, and temperatures. The flight experiment sensor was designed to operate from 1.5 meter range out to 110 meter range, with a field-of-view of 16 X 21 degrees. The VGS tracked its target at a 5 Hz rate and returned 6-degree-of-freedom information on the target's position and attitude relative to the sensor. The VGS was mounted in the Shuttle cargo bay, and its target was mounted on the Spartan spacecraft being carried on this mission. The VGS is a sensor designed to allow an automated vehicle to dock with a spacecraft equipped with a passive target. The VGS is a part of an Automated Rendezvous and Capture (AR&C) system being developed and tested by NASA. The orbital testing included operations with the target on the Shuttle's Remote Manipulator System (RMS) near the start of each flight of the VGS, long-range data (on the STS-95 flight) during the Shuttle rendezvous with the Spartan two days later, and some more RMS operations later in the mission. The data returned from the orbital testing included VGS diagnostics, acquisition, and tracking data, RMS positions, hand-held laser range data, tapes of the data from the VGS video camera, and orbital positioning data from the Spartan and the Shuttle to allow correlation of the VGS data with orbital best-estimate-of-truth data. The Video Guidance Sensor performed well in all phases of the testing, and the VGS is being incorporated into the ground testing of a complete automated rendezvous and docking system. Work on the development of the next generation VGS is continuing.

Howard, Richard T.↗

Rotor Re-Design for the SSME Fuel Flowmeter

The present report describes the process of redesigning a new rotor for the SSME Fuel Flowmeter. The new design addresses the specific requirement of a lower rotor speed which would allow the SSME operation at 1 15% rated power level without reaching a blade excitation by the wakes behind the hexagonal flow straightener upstream at frequencies close to the blade natural frequency. A series of calculations combining fleet flowmeters test data, airfoil fluid dynamics and CFD simulations of flow patterns behind the flowmeter's hexagonal straightener has led to a blade twist design alpha = alpha (radius) targeting a kf constant of 0.8256. The kf constant relates the fuel volume flow to the flowmeter rotor speed, for this particular value 17685 GPM at 3650 RPM. Based on this angle distribution, two actual blade designs were developed. A first design using the same blade airfoil as the original design targeted the new kf value only. A second design using a variable blade chord length and airfoil relative thickness targeted simultaneously the new kf value and an optimum blade design destined to provide smooth and stable operation and a significant increase in the blade natural frequency associated with the first bending mode, such that a comfortable margin could be obtained at 115% RPL. The second design is a result of a concurrent engineering process, during which several iterations were made in order to achieve a targeted blade natural frequency associated with the first bending mode of 1300 Hz. Water flow tests preliminary results indicate a kf value of 0.8179 for the f-irst design, which is within 1% of the target value. The second design rotor shows a natural frequency associated with the first bending mode of 1308 Hz, and a water-flow calibration constant of kf 0.8169.

Marcu, Bogdan↗

Perceptual Repetition Blindness Effects

The phenomenon of repetition blindness (RB) may reveal a new limitation on human perceptual processing. Recently, however, researchers have attributed RB to post-perceptual processes such as memory retrieval and/or reporting biases. The standard rapid serial visual presentation (RSVP) paradigm used in most RB studies is, indeed, open to such objections. Here we investigate RB using a "single-frame" paradigm introduced by Johnston and Hale (1984) in which memory demands are minimal. Subjects made only a single judgement about whether one masked target word was the same or different than a post-target probe. Confidence ratings permitted use of signal detection methods to assess sensitivity and bias effects. In the critical condition for RB a precue of the post-target word was provided prior to the target stimulus (identity precue), so that the required judgement amounted to whether the target did or did not repeat the precue word. In control treatments, the precue was either an unrelated word or a dummy.

Hochhaus, Larry↗

Spatial and Spatial Frequency Spreads of Masking: Measurements and A Contrast-Gain-Control Model

Masked pattern detection is affected by the mask's proximity to the target in both the spatial and the spatial frequency domains. We measured contrast thresholds for detection of a Gabor patch centered in a sample of static band-pass noise with a central noise-free aperture. To examine spatial spread, target and mask frequency were identical, at either 2, 4, or 8 cycles/degree (cpd), and the radius of the aperture was 0, 1/2 or 1 cycle of the noise band's center frequency. The results suggest that the spatial spread of masking is scale invariant, with the largest radius producing little masking. To examine spatial frequency spread, a radius of 0 (no aperture) was used with all pairings of 2, 4, and 8 cpd for target and mask. The results suggest that masking is asymmetrical over log frequency: 8 z 0 cpd noise masks a 2 cpd target, but 2 cpd noise does not mask an 8 cpd target. We have used these results to calibrate a model of contrast-gain-control.

Solomon, Joshua A.↗

Spatial and Spatial Frequency Spreads Of Masking: Measurements and a Contrast-Gain-Control Model

Masked pattern detection is affected by the mask's proximity to the target in both the spatial and the spatial frequency domains. We measured contrast thresholds for detection of a Gabor patch centered in a sample of static band-pass noise with a central noise-free aperture. To examine spatial spread, target and mask frequency were identical, at either 2, 4, or 8 cycles/degree (cpd), and the radius of the aperture was 0, 1/2 or 1 cycle of the noise band's center frequency. The results suggest that the spatial spread of masking is scale invariant, with the largest radius producing little masking. To examine spatial frequency spread, a radius of 0 (no aperture) was used with all pairings of 2,4, and 8 cpd for target and mask. The results suggest that masking is asymmetrical over log frequency: 8 cpd noise masks a 2 cpd target, but 2 cpd noise does not mask an 8 cpd target. We have used these results to calibrate a model of contrast-gain-control.

Solomon, J. A.↗

The Accuracy of Saccadic and Perceptual Decisions in Visual Search

Saccadic eye movements during search for a target embedded in noise are suboptimally guided by information about target location. Our goal is to compare the spatial information used to guide the saccades with that used for the perceptual decision. Three observers were asked to determine the location of a bright disk (diameter = 21 min) in white noise (signal-to-noise ratio = 4.2) from among 10 possible locations evenly spaced at 5.9 deg eccentricity. In the first of four conditions, observers used natural eye movements. In the three remaining conditions, observers fixated a central cross at all times. The fixation conditions consisted of three different presentation times (100, 200, 300 msec), each followed by a mask. Eye-position data were collected, with a resolution of (approximately) 0.2 deg. In the natural viewing condition, we measured. the accuracy with respect to the target and the latency of the first saccade. In the fixation conditions, we discarded trials in which observers broke fixation. Perceptual performance was computed for all conditions. Averaged across observers, the first saccade was correct (closest to the target location) for 56 +/- (SD) % of trials (chance = 10 %) and occurred after a latency of 313 +/- 56 msec. Perceptual performance averaged 53 +/- 4, 63 +/- 4, 65 +/- 2 % correct at 100, 200, and 300 msec, respectively. For the signal-to-noise ratio used, at the time of initiation of the first saccade, there is little difference between the amount of information about target location available to the perceptual and saccadic systems.

Eckstein, Miguel P.↗

Momentum Flux Measuring Instrument for Neutral and Charged Particle Flows

An instrument to measure the momentum flux (total pressure) of plasma and neutral particle jets onto a surface has been developed. While this instrument was developed for magnetized plasmas, the concept works for non-magnetized plasmas as well. We have measured forces as small as 10(exp -4) Newtons on a surface immersed in the plasma where small forces are due to ionic and neutral particles with kinetic energies on the order of a few eV impacting the surface. This instrument, a force sensor, uses a target plate (surface) that is immersed in the plasma and connected to one end of an alumina rod while the opposite end of the alumina rod is mechanically connected to a titanium beam on which four strain gauges are mounted. The force on the target generates torque causing strain in the beam. The resulting strain measurements can be correlated to a force on the target plate. The alumina rod electrically and thermally isolates the target plate from the strain gauge beam and allows the strain gauges to be located out of the plasma flow while also serving as a moment arm of several inches to increase the strain in the beam at the strain gauge location. These force measurements correspond directly to momentum flux and may be used with known plasma conditions to place boundaries on the kinetic energies of the plasma and neutral particles. The force measurements may also be used to infer thrust produced by a plasma propulsive device. Stainless steel, titanium, molybdenum, and aluminum flat target plates have been used. Momentum flux measurements of H2, D2, He, and Ar plasmas produced in a magnetized plasma device have been performed.

Chavers, Greg↗

Laser Image Contrast Enhancement System

An optical image enhancement system provides improved image contrast in imaging of a target in high temperature surroundings such as a furnace. The optical system includes a source of vertically polarized light such as laser and a beam splitter for receiving the light and directing the light toward the target. A retardation plate is affixed to a target-facing surface of the beam splitter and a vertical polarizer is disposed along a common optical path with the beam splitter between the retardation plate and the target. A horizontal polarizer disposed in the common optical path, receives light passing through a surface of the beam splitter opposed to the target-facing surface. An image detector is disposed at one end of the optical path. A band pass filter having a band pass filter characteristic matching the frequency of the vertically polarized light source is disposed in the path between the horizontal polarizer and the image detector. The use of circular polarization, together with cross polarizers, enables the reflected light to be passed to the detector while blocking thermal radiation.

Robert L Kurtz↗