Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TARGET SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Proton Radiography: Cross Section Measurements and Detector Development

Proton radiography has become an important tool for predicting the performance of stockpiled nuclear weapons. Current proton radiography experiments at LANSCE are confined to relatively small targets on the order of centimeters in size because of the low beam energy. LANL scientists have made radiographs with 12 and 24 GeV protons produced by the accelerator at Brookhaven National Laboratory. These energies are in the range required for hydrotest radiography. The design of a facility for hydrotest radiography requires knowledge of the cross sections for producing high-energy particles in the forward direction, which are incorporated into the Monte Carlo simulation used in designing the beam and detectors. There are few existing measurements of neutron production cross sections for proton-nuclei interactions in the 50 GeV range, and almost no data exist for forward neutron production, especially for heavy target nuclei. Thus the data from the MIPP EMCAL and HCAL, for which our group was responsible, are critical to proton radiography. Since neutrons and photons cannot be focused by magnets, they cause a background “fog” on the images. This problem can be minimized by careful design of the focusing system and detectors. The purpose of our research was to measure forward production of neutrons produced by high-energy proton beams striking a variety of targets. The forward-going particles carry most of the energy from a high-energy proton interaction, so these are the most important to proton radiography. This work was carried out in conjunction with the Fermilab E-907 (MIPP) collaboration. Our group was responsible for designing and building the E907 forward neutron and photon calorimeters. With the support of our Stewardship Science Academic Alliances grants, we were able to design, build, and commission the calorimeters on budget and ahead of schedule. The MIPP experiment accumulated a large amount of data in the first run that ended in early 2006. Our group has almost completed the analysis the forward neutron production data. Large dis-crepancies between our neutron production data and Monte Carlo expectations have been found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New description of the four-body breakup reaction

We present a novel method of smoothing discrete breakup cross sections calculated by the method of continuum-discretized coupled channels. The smoothing method based on the complex scaling method is tested with success for a {sup 58}Ni(d,pn) reaction at 80 MeV as an example of three-body breakup reactions and applied to a {sup 12}C({sup 6}He,nn {sup 4}He) reaction at 229.8 MeV as an example of four-body breakup reactions. Fast convergence of the breakup cross section with respect to extending the model space is confirmed. The method is also applied to {sup 12}C({sup 6}He,nn {sup 4}He) and {sup 208}Pb({sup 6}He,nn {sup 4}He) reactions at 240 MeV/A and compared with the experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

THE FREQUENCY OF LOW-MASS EXOPLANETS

We report first results from the Anglo-Australian Telescope Rocky Planet Search-an intensive, high-precision Doppler planet search targeting low-mass exoplanets in contiguous 48 night observing blocks. On this run, we targeted 24 bright, nearby and intrinsically stable Sun-like stars selected from the Anglo-Australian Planet Search's main sample. These observations have already detected one low-mass planet reported elsewhere (HD 16417b), and here we reconfirm the detection of HD 4308b. Further, we have Monte Carlo simulated data from this run on a star-by-star basis to produce robust detection constraints. These simulations demonstrate clear differences in the exoplanet detectability functions from star to star due to differences in sampling, data quality and intrinsic stellar stability. They reinforce the importance of star-by-star simulation when interpreting the data from Doppler planet searches. These simulations indicate that for some of our target stars we are sensitive to close-orbiting planets as small as a few Earth masses. The two low-mass planets present in our 24-star sample indicate that the exoplanet minimum mass function at low masses is likely to be a flat {alpha} {approx} -1 (for dN/dM {proportional_to} M {sup {alpha}}) and that between 15% {+-} 10% (at {alpha} = -0.3) and 48% {+-} 34% (at {alpha} = -1.3) of stars host planets with orbital periods of less than 16 days and minimum masses greater than 3 M {sub +}.

79 ASTRONOMY AND ASTROPHYSICS↗

Target Optimal Aperture Selection

This document describes the computation of optimal pixels for planetary transit targets. The method we describe is based on that used in the End-to-End Model (ETEM), which simulates Kepler science output. An optimal aperture for a target is defined as the set of pixels which maximizes the signal-to-noise ratio (SNR) for that target. The optimal aperture for a target is determined by using catalog data to generate, for that target, a synthetic image with all background stars and signals and a second synthetic image with the target star's flux only. These images are incorporated into a noise model, from which the SNR of each pixel is computed. The pixels around a target are summed in an order that maximizes the SNR with each term. As dimmer and dimmer pixels contribute to this sum, the SNR reaches a maximum and further terms decrease the SNR. The set of pixels whose SNR sums to this maximum value defines the optimal aperture.

Bryson, Stephen↗

Uncertainty Quantification of Monolithic Tungsten Target Block Fatigue

The current STS spallation target design consists of 21 water cooled, tantalum clad, monolithic tungsten blocks. The target wheel assembly rotates such that each target block receives a direct proton pulse every 1.4 seconds (21 blocks / 15 Hz pulses). The quasi-steady heating induced by the repetitive beam pulses creates a significant mean stress distribution in the target. On top of this, the rapid energy deposition from a proton pulse induces dynamic stress waves that are of the same order of magnitude as the mean stresses. Over the design goal of 5,000 operational hours per year for a decade, each target must withstand over 130 million repetitions of these dynamic stress events. The fatigue life prediction of the target blocks is a complex sequence of simulations that depend upon a set of input parameters. For the tungsten block, the end goal is the fatigue factor-of-safety (FOS). This study documents a new structural analysis routine using software available to U.S. national laboratories (e.g. CUBIT, Sierra Multiphysics, Dakota) that enables more rapid target fatigue analysis. The increased throughput is amenable to parameter sensitivity and uncertainty quantification (UQ) studies. A set of input parameters (ultimate strength, fatigue strength, density, elastic modulus, Poisson’s ratio, thermal conductivity, coefficient of thermal expansion, specific heat, flow rate) with expected ranges are documented based on literature data, recent experimental testing, and engineering judgement. UQ bounds the resulting fatigue FOS at [0.5, 3.4] using epistemic interval analysis. These bounds are expected to be wider due to model effects (discretization) and beam effects (focus, offset) that were not included. Parameter sensitivity underscores the importance of ultimate strength and fatigue strength of irradiated tungsten on the fatigue calculations.

43 PARTICLE ACCELERATORS↗

Properties of neutral charmed mesons in pA interactions at 70 GeV

The results of data handling for the E-184 experiment involving the irradiation of the active target, consisting of carbon, silicon, and lead plates by a 70-GeV proton beam are presented. When the two-prong neutral charmed meson decay signal was selected and the cross section for charm production at a near-threshold energy was estimated ({sigma}(cc-bar) = 7.1 {+-} 2.4(stat.) {+-} 1.4(syst.) Micro-Sign b/nucleon), some properties of D{sup 0} and D-bar{sup 0} were investigated. These include the atomic-weight dependence of the cross section on the target mass number (its A dependence); the differential cross sections d{sigma}/dp{sub t}{sup 2} and d{sigma}/dx{sub F}; and the dependence of the parameter {alpha} on x{sub F}, p{sub t}{sup 2}, and p{sub lab}. The experimental results are compared with the predictions of the FRITIOF7.02 program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Autonomous Soaring for Improved Endurance of a Small Uninhabited Air Vehicle

A relatively unexplored method to improve the endurance of an autonomous aircraft is to use buoyant plumes of air found in the lower atmosphere called thermals or updrafts. Glider pilots and birds commonly use updrafts to improve range, endurance, or cross-country speed. This report presents a quantitative analysis of a small electric-powered uninhabited air vehicle using updrafts to extend its endurance over a target location. A three-degree-of-freedom simulation of the uninhabited air vehicle was used to determine the yearly effect of updrafts on performance. Surface radiation and rawinsonde balloon measurements taken at Desert Rock, Nevada, were used to determine updraft size, strength, spacing, shape, and maximum height for the simulation. A fixed-width spiral path was used to search for updrafts at the same time as maintaining line-of-sight to the surface target position. Power was used only when the aircraft was flying at the lower-altitude limit in search of updrafts. Results show that an uninhabited air vehicle with a nominal endurance of 2 hours can fly a maximum of 14 hours using updrafts during the summer and a maximum of 8 hours during the winter. The performance benefit and the chance of finding updrafts both depend on what time of day the uninhabited air vehicle is launched. Good endurance and probability of finding updrafts during the year was obtained when the uninhabited air vehicle was launched 30 percent into the daylight hours after sunrise each day. Yearly average endurance was found to be 8.6 hours with these launch times.

Allen, Michael J.↗

Validation of Hermes-3 turbulence simulations against the TCV-X21 diverted L-mode reference case

Electrostatic flux-driven turbulence simulations with the Hermes-3 code are performed in TCV L-mode conditions in forward and reversed toroidal field configurations, and compared to the TCV-X21 reference dataset (Oliveira et al 2022 Nucl. Fusion 62 096001) qualitatively and with a quantitative methodology. Using only the magnetic equilibrium, total power across the separatrix (120 kW) and total particle flux to the targets (3 x 10 21 s −1 ) as inputs, the simulations produce time-averaged plasma profiles in good agreement with experiment. Shifts in the target peak location when the toroidal field direction is reversed are reproduced in simulation, including the experimentally observed splitting of the outer strike point into two density peaks. The overall normalized discrepancy between simulation and observation is better than any previously reported in the reversed field configuration, and matches the best previously reported in forward field configuration. Differences between simulation and experiment include density profiles inside the separatrix and at the inner target in forward (favorable $\bigtriangledown B$) field configuration. These differences in target temperature in forward field configuration lead to differences in the balance of current to the inner and outer divertor in the private flux region. The cause of these differences is most likely the lack of neutral gas in these simulations, indicating that even in low recycling regimes neutral gas plays an important role in determining edge plasma profiles. These conclusions are consistent with findings in Oliveira et al (2022 https://github.com/SPCData/TCV-X21).

Physics - Plasma physics↗

Convective Heating of the LIFE Engine Target During Injection

Target survival in the hostile, high temperature xenon environment of the proposed Laser Inertial Fusion Energy (LIFE) engine is critical. This work focuses on the flow properties and convective heat load imposed upon the surface of the indirect drive target while traveling through the xenon gas. While this rarefied flow is traditionally characterized as being within the continuum regime, it is approaching transition where conventional CFD codes reach their bounds of operation. Thus ANSYS, specifically the Navier-Stokes module CFX, will be used in parallel with direct simulation Monte Carlo code DS2V and analytically and empirically derived expressions for heat transfer to the hohlraum for validation. Comparison of the viscous and thermal boundary layers of ANSYS and DS2V were shown to be nearly identical, with the surface heat flux varying less than 8% on average. From the results herein, external baffles have been shown to reduce this heat transfer to the sensitive laser entrance hole (LEH) windows and optimize target survival independent of other reactor parameters.

42 ENGINEERING↗

Anatomy-Based Inverse Planning Simulated Annealing Optimization in High-Dose-Rate Prostate Brachytherapy: Significant Dosimetric Advantage Over Other Optimization Techniques

Purpose: To perform an independent validation of an anatomy-based inverse planning simulated annealing (IPSA) algorithm in obtaining superior target coverage and reducing the dose to the organs at risk. Method and Materials: In a recent prostate high-dose-rate brachytherapy protocol study by the Radiation Therapy Oncology Group (0321), our institution treated 20 patients between June 1, 2005 and November 30, 2006. These patients had received a high-dose-rate boost dose of 19 Gy to the prostate, in addition to an external beam radiotherapy dose of 45 Gy with intensity-modulated radiotherapy. Three-dimensional dosimetry was obtained for the following optimization schemes in the Plato Brachytherapy Planning System, version 14.3.2, using the same dose constraints for all the patients treated during this period: anatomy-based IPSA optimization, geometric optimization, and dose point optimization. Dose-volume histograms were generated for the planning target volume and organs at risk for each optimization method, from which the volume receiving at least 75% of the dose (V{sub 75%}) for the rectum and bladder, volume receiving at least 125% of the dose (V{sub 125%}) for the urethra, and total volume receiving the reference dose (V{sub 100%}) and volume receiving 150% of the dose (V{sub 150%}) for the planning target volume were determined. The dose homogeneity index and conformal index for the planning target volume for each optimization technique were compared. Results: Despite suboptimal needle position in some implants, the IPSA algorithm was able to comply with the tight Radiation Therapy Oncology Group dose constraints for 90% of the patients in this study. In contrast, the compliance was only 30% for dose point optimization and only 5% for geometric optimization. Conclusions: Anatomy-based IPSA optimization proved to be the superior technique and also the fastest for reducing the dose to the organs at risk without compromising the target coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ion heating dynamics in solid buried layer targets irradiated by ultra-short intense laser pulses

We investigate bulk ion heating in solid buried layer targets irradiated by ultra-short laser pulses of relativistic intensities using particle-in-cell simulations. Our study focuses on a CD{sub 2}-Al-CD{sub 2} sandwich target geometry. We find enhanced deuteron ion heating in a layer compressed by the expanding aluminium layer. A pressure gradient created at the Al-CD{sub 2} interface pushes this layer of deuteron ions towards the outer regions of the target. During its passage through the target, deuteron ions are constantly injected into this layer. Our simulations suggest that the directed collective outward motion of the layer is converted into thermal motion inside the layer, leading to deuteron temperatures higher than those found in the rest of the target. This enhanced heating can already be observed at laser pulse durations as low as 100 fs. Thus, detailed experimental surveys at repetition rates of several ten laser shots per minute are in reach at current high-power laser systems, which would allow for probing and optimizing the heating dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Postoperative Intensity-Modulated Radiotherapy in Low-Risk Endometrial Cancers: Final Results of a Phase I Study

Purpose: To determine the maximum tolerated dose of short-course radiotherapy (intensity-modulated radiotherapy technique) to the upper two thirds of the vagina in endometrial cancers with low risk of local recurrence. Patients and Methods: A Phase I clinical trial was performed. Eligible patients had low-risk resected primary endometrial adenocarcinomas. Radiotherapy was delivered in 5 fractions over 1 week. The planning target volume was the clinical target volume plus 5 mm. The clinical target volume was defined as the upper two thirds of the vagina as evidenced at CT simulation by a vaginal radio-opaque device. The planning target volume was irradiated by a seven-field intensity-modulated radiotherapy technique, planned by the Plato Sunrise inverse planning system. A first cohort of 6 patients received 25 Gy (5-Gy fractions), and a subsequent cohort received 30 Gy (6-Gy fractions). The Common Toxicity Criteria scale, version 3.0, was used to score toxicity. Results: Twelve patients with endometrial cancer were enrolled. Median age was 58 years (range, 49-74 years). Pathologic stage was IB (83.3%) and IC (16.7%). Median tumor size was 30 mm (range, 15-50 mm). All patients completed the prescribed radiotherapy. No patient experienced a dose-limiting toxicity at the first level, and the radiotherapy dose was escalated from 25 to 30 Gy. No patients at the second dose level experienced dose-limiting toxicity. The most common Grade 2 toxicity was gastrointestinal, which was tolerable and manageable. Conclusions: The maximum tolerated dose of short-course radiotherapy was 30 Gy at 6 Gy per fraction. On the basis of this result, we are conducting a Phase II study with radiotherapy delivered at 30 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enabling High-Energy-Density Physics Using X-Ray Free Electron Lasers

New High-Energy-Density (HED) Physics research facilities, such as x-ray free electron lasers (XFEL) are becoming available to the research community. These new tools can be used to address stockpile stewardship science questions in the HED regime with greater accuracy and in parameter ranges not previously accessible. Two important challenges that must be overcome before using the XFEL are developing simulation tools needed to design the experiment and developing large quantities of inexpensive targets from which the HED state is created. We developed two-dimensional simulations in a new geometry (planar) to determine basic plasma parameters that could be expected in a notional experiment. We developed a postprocessor that used the results of the simulations to predict the x-ray Thomson scattering (XRTS) signal that yield the plasma density and pressure at a specified location and time. Finally, we developed several possible target geometries that are inexpensive and easy to use. With these tools in hand, the risk in designing an experiment for an XFEL is significantly reduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detachment scalings derived from 1D scrape-off-layer simulations

Fusion power plants will require detachment to mitigate sputtering and keep divertor heat fluxes at tolerable levels. Controlling detachment on these devices may require the use of real-time scrape-off-layer modeling to complement the limited set of available diagnostics. In this work, we use the configurable Hermes-3 edge modeling framework to perform time-dependent, fixed-fraction-impurity 1D detachment simulations. Although currently far from real-time, these simulations are used to investigate time-dependent effects and the minimum physics set required for control-relevant modeling. We show that these simulations reproduce the expected rollover of the target ion flux — a typical characteristic of detachment onset. We also perform scans of the input heat flux and impurity concentration and show that the steady-state results closely match the scalings predicted by the 0D time-independent Lengyel–Goedheer model. This allows us to indirectly compare to SOLPS simulations, which find a similar scaling but a lower value for the impurity concentration required for detachment for given upstream conditions. We use this result to suggest a series of improvements for the Hermes simulations, and finally show simulations demonstrating the impact of time-dependence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flow Processes in the Dry Regime: The Effect on Capillary Barrier Performance

Engineered capillary barriers typically consist of two layers of granular materials designed so that the contrast in material hydraulic properties and sloping interface retains infiltrating water in the upper layer. We report here on the results of two bench-top capillary barrier experiments, interpretation, and numerical modeling. We measured hydraulic parameters for two coarse materials using standard methods and found that the materials had similar hydraulic properties despite being morphologically different (round vs. angular). The round sand provided a better functioning capillary barrier than the angular sand, but neither experiment could be characterized as a perfectly working capillary barrier. In both cases, more than 93% of the infiltrating water was successfully diverted from the lower layer, however, infiltration into the underlying layer was observed in both systems. Based on this work, we believe that non-continuum processes such as vapor diffusion and film flow contribute to the observed phenomena and are important aspects to consider with respect to capillary barrier design, as well as dry vadose zone processes in general. Using a theoretical film flow equation that incorporates the surface geometry of the porous material we found that infiltration into the coarse underlying sand layer appeared to be dominated by water film flow. The NUFT (Non-isothermal Unsaturated-saturated Flow and Transport) model was used for qualitative comparison simulations. We were able to reproduce the barrier breach observed in the experiments using targeted parameter adjustment, by which pseudo-film flow was successfully simulated.

36 MATERIALS SCIENCE↗

Optical pattern recognition III; Proceedings of the Meeting, Orlando, FL, Apr. 21, 22, 1992

Consideration is given to transitioning of optical processing into systems (TOPS), optical correlator hardware, phase-only optical correlation filters, optical distortion-invariant correlation filters, and optical neural networks. Particular attention is given to a test target for optical correlators, a TOPS electronic warfare channelizer program, a portable video-rate optical correlator, a joint transform correlator employing electron trapping materials, a novelty filtered optical correlator using a photorefractive crystal, a comparison of correlation performance of smart ternary phase-amplitude filters with gray-scale and binary input scenes, real-time distortion-tolerant composite filters for automatic target identification, landscaping the correlation surface, fast designing of a circular harmonic filter using simulated annealing, feature-based correlation filters for distortion invariance, automatic target recognition using a feature-based optical neural network, and a holographic inner-product processor for pattern recognition.

Casasent, David P.↗

Study of Spherical Array Target for Long-Baseline Neutrino Experiment

Spherical Array Target was studied by implementing the geometry in LBNE's Beam Simulation source code g4lbne version v3r2p4 and Monte Carlo. To compare with Nominal LBNE target, unoscillated Far Detector neutrino flux was produced using different parameters: sphere diameter 17mm and 13mm, different longitudinal positions, two interaction length and less, beam size R/3 and 1.7mm, and beam offset from 50 $\mu$m to 1mm. The 1.86 interaction length (901mm), 17mm diameter target, with beam size 1.7mm gives higher $\nu_{\mu}$ flux up to 10% from 0-3.5 GeV, and suppresses flux up to 70% at energy higher than 3.5 GeV.

43 PARTICLE ACCELERATORS↗

Scheduling strategies for the ESPRESSO follow-up of TESS targets

ABSTRACT Radial-velocity follow-up of stars harbouring transiting planets detected by TESS is expected to require very large amounts of expensive telescope time in the next few years. Therefore, scheduling strategies should be implemented to maximize the amount of information gathered about the target planetary systems. We consider myopic and non-myopic versions of a novel uniform-in-phase scheduler, as well as a random scheduler, and compare these scheduling strategies with respect to the bias, accuracy and precision achieved in recovering the mass and orbital parameters of transiting and non-transiting planets. This comparison is carried out based on realistic simulations of radial-velocity follow-up with ESPRESSO of a sample of 50 TESS target stars, with simulated planetary systems containing at least one transiting planet with a radius below 4R⊕. Radial-velocity data sets were generated under reasonable assumptions about their noise component, including that resulting from stellar activity, and analysed using a fully Bayesian methodology. We find the random scheduler leads to a more biased, less accurate, and less precise, estimation of the mass of the transiting exoplanets. No significant differences are found between the results of the myopic and non-myopic implementations of the uniform-in-phase scheduler. With only about 22 radial velocity measurements per data set, our novel uniform-in-phase scheduler enables an unbiased (at the level of 1 per cent) measurement of the masses of the transiting planets, while keeping the average relative accuracy and precision around 16 per cent and 23 per cent, respectively. The number of non-transiting planets detected is similar for all the scheduling strategies considered, as well as the bias, accuracy and precision with which their masses and orbital parameters are recovered.

Cabona, L.↗