Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Standardization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Direct CP violation and the ΔI=1/2 rule in K→ππ decay from the standard model

We present a lattice QCD calculation of the Δ I = 1 / 2 , K → π π decay amplitude A 0 and ϵ ' , the measure of direct C P violation in K → π π decay, improving our 2015 calculation [1] of these quantities. Both calculations were performed with physical kinematics on a 32 3 × 64 lattice with an inverse lattice spacing of a - 1 = 1.3784 ( 68 ) GeV . However, the current calculation includes nearly 4 times the statistics and numerous technical improvements allowing us to more reliably isolate the π π ground state and more accurately relate the lattice operators to those defined in the standard model. We find Re ( A 0 ) = 2.99 ( 0.32 ) ( 0.59 ) × 10 - 7 GeV and Im ( A 0 ) = - 6.98 ( 0.62 ) ( 1.44 ) × 10 - 11 GeV , where the errors are statistical and systematic, respectively. The former agrees well with the experimental result Re ( A 0 ) = 3.3201 ( 18 ) × 10 - 7 GeV . These results for A 0 can be combined with our earlier lattice calculation of A 2 [2] to obtain Re ( ϵ ' / ϵ ) = 21.7 ( 2.6 ) ( 6.2 ) ( 5.0 ) × 10 - 4 , where the third error represents omitted isospin breaking effects, and Re ( A 0 ) / Re ( A 2 ) = 19.9 ( 2.3 ) ( 4.4 ) . The first agrees well with the experimental result of Re ( ϵ ' / ϵ ) = 16.6 ( 2.3 ) × 10 - 4 . A comparison of the second with the observed ratio Re ( A 0 ) / Re ( A 2 ) = 22.45 ( 6 ) , demonstrates the standard model origin of this “ Δ I = 1 / 2 rule” enhancement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmological forecasts for future galaxy surveys with the linear point standard ruler: Toward consistent BAO analyses far from a fiducial cosmology

The linear point (LP) standard ruler was identified as the basis of a purely geometric method for exploiting the baryon acoustic oscillations (BAO). The LP exploits the BAO feature imprinted in the galaxy two-point correlation function to measure cosmological distances independent of any specific cosmological model. We forecast the expected precision of future and ongoing spectroscopic galaxy surveys to measure distances leveraging the linear point. We investigate the cosmological implications of our forecasted results. We focus in particular on a relevant working example: the detection of the late-time cosmic acceleration independent of other cosmological probes. Further, our findings show that, even within the Λ⁢CDM standard cosmological paradigm, estimated distances need to be reliable over a very wide parameter range in order to realize their maximum utility. This is particularly relevant if we aim to properly characterize cosmological tensions. The LP is a promising candidate approach to achieve this reliability. In contrast, widely employed procedures in BAO analysis estimate distances keeping fixed cosmological parameters to fiducial values close to cosmic-microwave-background constraints in flat-Λ⁢CDM. It is unclear whether they are purely geometric methods. Moreover, they rely on untested extrapolations to explore the parameter space away from those fiducial flat-Λ⁢CDM values. We recommend that all BAO methodologies be validated across the full range of models and parameters over which their results are quoted, first by means of linear predictions and then N -body simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Delayed recombination and standard rulers

Measurements of baryonic acoustic oscillations (BAOs) in galaxy surveys have been recognized as a powerful tool for constraining dark energy. However, this method relies on the knowledge of the size of the acoustic horizon at recombination derived from cosmic microwave background (CMB) anisotropy measurements. This estimate is typically derived assuming a standard recombination scheme; additional radiation sources can delay recombination altering the cosmic ionization history and the cosmological inferences drawn from CMB and BAO data. In this paper we quantify the effect of delayed recombination on the determination of dark energy parameters from future BAO surveys such as the Baryon Oscillation Spectroscopic Survey and the Wide-Field Multi-Object Spectrograph. We find the impact to be small but still not negligible. In particular, if recombination is nonstandard (to a level still allowed by CMB data), but this is ignored, future surveys may incorrectly suggest the presence of a redshift-dependent dark energy component. On the other hand, in the case of delayed recombination, adding to the analysis one extra parameter describing deviations from standard recombination does not significantly degrade the error bars on dark energy parameters and yields unbiased estimates. This is due to the CMB-BAO complementarity.

39↗

Duality linking standard and tachyon scalar field cosmologies

In this work we investigate the duality linking standard and tachyon scalar field homogeneous and isotropic cosmologies in N+1 dimensions. We determine the transformation between standard and tachyon scalar fields and between their associated potentials, corresponding to the same background evolution. We show that, in general, the duality is broken at a perturbative level, when deviations from a homogeneous and isotropic background are taken into account. However, we find that for slow-rolling fields the duality is still preserved at a linear level. We illustrate our results with specific examples of cosmological relevance, where the correspondence between scalar and tachyon scalar field models can be calculated explicitly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Group velocity and causality in standard relativistic resistive magnetohydrodynamics

Group velocity of electromagnetic waves in plasmas derived by standard relativistic resistive magnetohydrodynamics equations is superluminal. If we assume that the group velocity represents the propagation velocity of a signal, we have to worry about the causality problem. That is, some acausal phenomena may be induced, such as information transportation to the absolute past and a spontaneous decrease in the entropy. Here, we tried to find the acausal phenomena using standard relativistic resistive magnetohydrodynamics numerical simulations in the suggested situation of the acausal phenomena. The calculation results showed that even in such situations no acausal effect happens. The numerical result with respect to the velocity limit of the information transportation is consistent with a linear theory of wave train propagation. Our results assure that we can use these equations without the problems of acausal phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

R K and future b → s ℓ ℓ physics beyond the standard model opportunities

Flavor changing neutral current |ΔB|=|ΔS|=1 processes are sensitive to possible new physics at the electroweak scale and beyond, providing detailed information about flavor, chirality and Lorentz structure. Recently the LHCb collaboration announced a 2.6σ deviation in the measurement of $R_K={\cal{B}}(\bar B \to \bar K \mu \mu)/{\cal{B}}(\bar B \to \bar K ee)$ from the standard model's prediction of lepton universality. We identify dimension six operators which could explain this deviation and study constraints from other measurements. Vector and axial-vector four-fermion operators with flavor structure $\bar s b \bar \ell \ell$ can provide a good description of the data. Tensor operators cannot describe the data. Pseudo-scalar and scalar operators only fit the data with some fine-tuning; they can be further probed with the $\bar B \to \bar K ee$ angular distribution. The data appears to point towards $C_9^{\rm NP \mu} = -C_{10}^{\rm NP \mu }<0$, an $SU(2)_{L}$ invariant direction in parameter space supported by R K , the $\bar B \to \bar K^* \mu \mu$ forward-backward asymmetry and the $\bar B_s \to \mu \mu$ branching ratio, which is currently allowed to be smaller than the standard model prediction. We present two leptoquark models which can explain the FCNC data and give predictions for the LHC and rare decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Higgs boson mass in the standard model at two-loop order and beyond

We calculate the mass of the Higgs boson in the standard model in terms of the underlying Lagrangian parameters at complete 2-loop order with leading 3-loop corrections. A computer program implementing the results is provided. The program also computes and minimizes the standard model effective potential in Landau gauge at 2-loop order with leading 3-loop corrections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraining the top-Higgs sector of the standard model effective field theory

Working in the framework of the Standard Model effective field theory, we study chirality-flipping couplings of the top quark to Higgs and gauge bosons. In this paper, we discuss in detail the renormalization-group evolution to lower energies and investigate direct and indirect contributions to high- and low-energy $CP$-conserving and $CP$-violating observables. Our analysis includes constraints from collider observables, precision electroweak tests, flavor physics, and electric dipole moments. We find that indirect probes are competitive or dominant for both $CP$-even and $CP$-odd observables, even after accounting for uncertainties associated with hadronic and nuclear matrix elements, illustrating the importance of including operator mixing in constraining the Standard Model effective field theory. We also study scenarios where multiple anomalous top couplings are generated at the high scale, showing that while the bounds on individual couplings relax, strong correlations among couplings survive. In conclusion, we find that enforcing minimal flavor violation does not significantly affect the bounds on the top couplings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Complete asymptotically safe embedding of the standard model

We introduce and discuss the “Tetrad Model”, a large color/flavor embedding of the Standard model which has an interacting ultraviolet fixed point. It is demonstrated that its extended-Pati-Salam symmetry is broken radiatively via the Coleman-Weinberg mechanism, while the remaining electroweak symmetry is broken when mass-squared terms run negative. In the IR the theory yields just the Standard Model, augmented by the fact that the Higgs fields carry the same generation indices as the matter fields. It is also shown that the Higgs mass-squareds develop a hierarchical structure in the IR, from a UV theory that is asymptotically flavor symmetric, opening up an interesting direction for explaining the emergence of the observed flavor structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Standard map in magnetized relativistic systems: Fixed points and regular acceleration

We investigate the concept of a standard map for the interaction of relativistic particles and electrostatic waves of arbitrary amplitudes, under the action of external magnetic fields. The map is adequate for physical settings where waves and particles interact impulsively, and allows for a series of analytical result to be exactly obtained. Unlike the traditional form of the standard map, the present map is nonlinear in the wave amplitude and displays a series of peculiar properties. Among these properties we discuss the relation involving fixed points of the maps and accelerator regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Converting Clinical Pathways to BPM+ Standards: A Case Study in Stable Ischemic Heart Disease

Clinical pathways (CPs) are structured healthcare plans designed to implement evidence-based clinical guidelines, medical algorithms, and protocols. In recent years, a community called BPM+ Health has worked to establish a shareable and computer-consumable representation of CP, leveraging standard notations. These notations, collectively referred to as BPM+, include the Business Process Management and Notation (BPMN), Case Management Model and Notation (CMMN), and Decision Model and Notation (DMN), which aim to support clinical management and standardized communication between different stakeholders. However, the adaptation of these notations for the existing guidelines has largely been left unexplored. This paper introduces procedural steps and criteria considerations to apply components of BPM+ notations to reconstruct a guideline for Stable Ischemic Heart Disease. This paper describes how each of the three different notations is mapped to a medical guideline and discusses the advantages and limitations of representing CPs with BPM+ as compared with paper-based medical guidelines.

Chae, Junghoon↗

Evolution of the IEEE P7009 Standard: Towards Fail-Safe Design of Autonomous Systems

Autonomous systems are complex, diverse, and likely be used in environments that change unpredictably. We must develop mechanisms to cope with failures, potentially caused by both the natural stresses of the operating environment and the system's inadequate environmental models. Failures also arise from system component wear. In 2016, the IEEE launched the Global Initiative on Ethics of Autonomous and Intelligent Systems in response to the proliferation of increasingly-autonomous systems. A cornerstone of this initiative is the IEEE P7000 series of projects, which set the standards for the future of ethical intelligent and autonomous technologies. This paper describes the ongoing development of the IEEE P7009 standard on “Fail-Safe Design of Autonomous and Semi-Autonomous Systems”. We provide a collective perspective on the ongoing development of IEEE P7009, and outline the objectives, current approaches, issues under discussion, and two exemplar use cases from different sectors: one high-regulation, the other low-regulation.

Farrell, Marie↗

Changes Required in the PMU standards

The Phasor Measurement Unit (PMU) is a representational measuring instrument that gives time-stamped measurements of the power system on the assumption that the measurand can be represented as sinusoidal. However, two standards defining the measured quantities unnecessarily corrupt the results and limit the capabilities of the PMU, and are beginning to tax communications systems. This paper examines the two mistakes in the PMU standards, and proposes a solution.

PMU measurement, phase, phasor, measurement theory↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Binary pseudorandom array test standard optimized for characterization of large field-of-view optical interferometers

Recently, a technique for calibrating the modulation transfer function (MTF) of a broad variety of metrology instrumentation has been demonstrated. This technique is based on test samples structured as one-dimensional binary pseudo-random (BPR) sequences and two-dimensional BPR arrays (BPRAs). The inherent power spectral density of BPR gratings (sequences) and arrays has a deterministic white-noise-like character that allows direct determination of the MTF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. As such, the BPR samples satisfy the characteristics of a test standard: functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. Here we discuss our recent developments directed to the optimization of the sample design, fabrication, application, and data processing procedures, suitable for thorough characterization of large aperture optical interferometers. Compared with the previous coded-aperture based design, the improved, 'highly randomized' BPRA pattern of the new test standard provides better accuracy and reliability of instrument MTF and aberration characterization, and enables operation optimization of large aperture optical interferometers. We describe the pattern generation algorithm and tests to verify the compliance to desired BPRA topography. The data acquisition and analysis procedures for different applications of the technique are also discussed.

Yashchuk, Valeriy V.↗

Computer-aided detection of interstitial abnormalities in chest radiographs using a reference standard based on computed tomography

A computer-aided detection (CAD) system is presented for the localization of interstitial lesions in chest radiographs. The system analyzes the complete lung fields using a two-class supervised pattern classification approach to distinguish between normal texture and texture affected by interstitial lung disease. Analysis is done pixel-wise and produces a probability map for an image where each pixel in the lung fields is assigned a probability of being abnormal. Interstitial lesions are often subtle and ill defined on x-rays and hence difficult to detect, even for expert radiologists. Therefore a new, semiautomatic method is proposed for setting a reference standard for training and evaluating the CAD system. The proposed method employs the fact that interstitial lesions are more distinct on a computed tomography (CT) scan than on a radiograph. Lesion outlines, manually drawn on coronal slices of a CT scan of the same patient, are automatically transformed to corresponding outlines on the chest x-ray, using manually indicated correspondences for a small set of anatomical landmarks. For the texture analysis, local structures are described by means of the multiscale Gaussian filter bank. The system performance is evaluated with ROC analysis on a database of digital chest radiographs containing 44 abnormal and 8 normal cases. The best performance is achieved for the linear discriminant and support vector machine classifiers, with an area under the ROC curve (A{sub z}) of 0.78. Separate ROC curves are built for classification of abnormalities of different degrees of subtlety versus normal class. Here the best performance in terms of A{sub z} is 0.90 for differentiation between obviously abnormal and normal pixels. The system is compared with two human observers, an expert chest radiologist and a chest radiologist in training, on evaluation of regions. Each lung field is divided in four regions, and the reference standard and the probability maps are converted into region scores. The system performance does not significantly differ from that of the observers, when the perihilar regions are excluded from evaluation, and reaches A{sub z}=0.85 for the system, with A{sub z}=0.88 for both observers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical shape model-based reconstruction of a scaled, patient-specific surface model of the pelvis from a single standard AP x-ray radiograph

Purpose: The aim of this article is to investigate the feasibility of using a statistical shape model (SSM)-based reconstruction technique to derive a scaled, patient-specific surface model of the pelvis from a single standard anteroposterior (AP) x-ray radiograph and the feasibility of estimating the scale of the reconstructed surface model by performing a surface-based 3D/3D matching. Methods: Data sets of 14 pelvises (one plastic bone, 12 cadavers, and one patient) were used to validate the single-image based reconstruction technique. This reconstruction technique is based on a hybrid 2D/3D deformable registration process combining a landmark-to-ray registration with a SSM-based 2D/3D reconstruction. The landmark-to-ray registration was used to find an initial scale and an initial rigid transformation between the x-ray image and the SSM. The estimated scale and rigid transformation were used to initialize the SSM-based 2D/3D reconstruction. The optimal reconstruction was then achieved in three stages by iteratively matching the projections of the apparent contours extracted from a 3D model derived from the SSM to the image contours extracted from the x-ray radiograph: Iterative affine registration, statistical instantiation, and iterative regularized shape deformation. The image contours are first detected by using a semiautomatic segmentation tool based on the Livewire algorithm and then approximated by a set of sparse dominant points that are adaptively sampled from the detected contours. The unknown scales of the reconstructed models were estimated by performing a surface-based 3D/3D matching between the reconstructed models and the associated ground truth models that were derived from a CT-based reconstruction method. Such a matching also allowed for computing the errors between the reconstructed models and the associated ground truth models. Results: The technique could reconstruct the surface models of all 14 pelvises directly from the landmark-based initialization. Depending on the surface-based matching techniques, the reconstruction errors were slightly different. When a surface-based iterative affine registration was used, an average reconstruction error of 1.6 mm was observed. This error was increased to 1.9 mm, when a surface-based iterative scaled rigid registration was used. Conclusions: It is feasible to reconstruct a scaled, patient-specific surface model of the pelvis from single standard AP x-ray radiograph using the present approach. The unknown scale of the reconstructed model can be estimated by performing a surface-based 3D/3D matching.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: Modeling a complex micro-multileaf collimator using the standard BEAMnrc distribution

Purpose: The component modules in the standard BEAMnrc distribution may appear to be insufficient to model micro-multileaf collimators that have trifaceted leaf ends and complex leaf profiles. This note indicates, however, that accurate Monte Carlo simulations of radiotherapy beams defined by a complex collimation device can be completed using BEAMnrc's standard VARMLC component module. Methods: That this simple collimator model can produce spatially and dosimetrically accurate microcollimated fields is illustrated using comparisons with ion chamber and film measurements of the dose deposited by square and irregular fields incident on planar, homogeneous water phantoms. Results: Monte Carlo dose calculations for on-axis and off-axis fields are shown to produce good agreement with experimental values, even on close examination of the penumbrae. Conclusions: The use of a VARMLC model of the micro-multileaf collimator, along with a commissioned model of the associated linear accelerator, is therefore recommended as an alternative to the development or use of in-house or third-party component modules for simulating stereotactic radiotherapy and radiosurgery treatments. Simulation parameters for the VARMLC model are provided which should allow other researchers to adapt and use this model to study clinical stereotactic radiotherapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗