Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Megavoltage Image-Based Dynamic Multileaf Collimator Tracking of a NiTi Stent in Porcine Lungs on a Linear Accelerator

Purpose: To investigate the accuracy and potential limitations of MV image-based dynamic multileaf collimator (DMLC) tracking in a porcine model on a linear accelerator. Methods and Materials: A thermo-expandable NiTi stent designed for kilovoltage (kV) X-ray visualization of lung lesions was inserted into the bronchia of three anaesthetized Goettingen minipigs. A four-dimensional computed tomography scan was used for planning a five-field conformal treatment with circular multileaf collimator (MLC) apertures. A 22.5 Gy single fraction treatment was delivered to the pigs. The peak-to-peak stent motion was 3 to 8 mm, with breathing periods of 1.2 to 4 s. Before treatment, X-ray images were used for image-guided setup based on the stent. During treatment delivery, continuous megavoltage (MV) portal images were acquired at 7.5 Hz. The stent was segmented in the images and used for continuous adaptation of the MLC aperture. Offline, the tracking error in beam's eye view of the treatment beam was calculated for each MV image as the difference between the MLC aperture center and the segmented stent position. The standard deviations of the systematic error {Sigma} and the random error {sigma} were determined and compared with the would-be errors for a nontracking treatment with pretreatment image-guided setup. Results: Reliable stent segmentation was obtained for 11 of 15 fields. Segmentation failures occurred when image contrast was dominated by overlapping anatomical structures (ribs, diaphragm) rather than by the stent, which was designed for kV rather than MV X-ray visibility. For the 11 fields with reliable segmentation, {Sigma} was 0.5 mm/0.4 mm in the two imager directions, whereas {sigma} was 0.5 mm/1.1 mm. Without tracking, {Sigma} and {sigma} would have been 1.7 mm/1.4 mm and 0.8 mm/1.4 mm, respectively. Conclusion: For the first time, in vivo DMLC tracking has been demonstrated on a linear accelerator showing the potential for improved targeting accuracy. The study mimicked the envisioned patient workflow of future patient treatments. Clinical implementation of MV image-based tracking would require markers designed for MV visibility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dentalmaps: Automatic Dental Delineation for Radiotherapy Planning in Head-and-Neck Cancer

Purpose: To propose an automatic atlas-based segmentation framework of the dental structures, called Dentalmaps, and to assess its accuracy and relevance to guide dental care in the context of intensity-modulated radiotherapy. Methods and Materials: A multi-atlas-based segmentation, less sensitive to artifacts than previously published head-and-neck segmentation methods, was used. The manual segmentations of a 21-patient database were first deformed onto the query using nonlinear registrations with the training images and then fused to estimate the consensus segmentation of the query. Results: The framework was evaluated with a leave-one-out protocol. The maximum doses estimated using manual contours were considered as ground truth and compared with the maximum doses estimated using automatic contours. The dose estimation error was within 2-Gy accuracy in 75% of cases (with a median of 0.9 Gy), whereas it was within 2-Gy accuracy in 30% of cases only with the visual estimation method without any contour, which is the routine practice procedure. Conclusions: Dose estimates using this framework were more accurate than visual estimates without dental contour. Dentalmaps represents a useful documentation and communication tool between radiation oncologists and dentists in routine practice. Prospective multicenter assessment is underway on patients extrinsic to the database.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On-Line Use of Three-Dimensional Marker Trajectory Estimation From Cone-Beam Computed Tomography Projections for Precise Setup in Radiotherapy for Targets With Respiratory Motion

Purpose: To develop and evaluate accurate and objective on-line patient setup based on a novel semiautomatic technique in which three-dimensional marker trajectories were estimated from two-dimensional cone-beam computed tomography (CBCT) projections. Methods and Materials: Seven treatment courses of stereotactic body radiotherapy for liver tumors were delivered in 21 fractions in total to 6 patients by a linear accelerator. Each patient had two to three gold markers implanted close to the tumors. Before treatment, a CBCT scan with approximately 675 two-dimensional projections was acquired during a full gantry rotation. The marker positions were segmented in each projection. From this, the three-dimensional marker trajectories were estimated using a probability based method. The required couch shifts for patient setup were calculated from the mean marker positions along the trajectories. A motion phantom moving with known tumor trajectories was used to examine the accuracy of the method. Trajectory-based setup was retrospectively used off-line for the first five treatment courses (15 fractions) and on-line for the last two treatment courses (6 fractions). Automatic marker segmentation was compared with manual segmentation. The trajectory-based setup was compared with setup based on conventional CBCT guidance on the markers (first 15 fractions). Results: Phantom measurements showed that trajectory-based estimation of the mean marker position was accurate within 0.3 mm. The on-line trajectory-based patient setup was performed within approximately 5 minutes. The automatic marker segmentation agreed with manual segmentation within 0.36 {+-} 0.50 pixels (mean {+-} SD; pixel size, 0.26 mm in isocenter). The accuracy of conventional volumetric CBCT guidance was compromised by motion smearing ({<=}21 mm) that induced an absolute three-dimensional setup error of 1.6 {+-} 0.9 mm (maximum, 3.2) relative to trajectory-based setup. Conclusions: The first on-line clinical use of trajectory estimation from CBCT projections for precise setup in stereotactic body radiotherapy was demonstrated. Uncertainty in the conventional CBCT-based setup procedure was eliminated with the new method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SPECT Analysis of Cardiac Perfusion Changes After Whole-Breast/Chest Wall Radiation Therapy With or Without Active Breathing Coordinator: Results of a Randomized Phase 3 Trial

Purpose: Cardiac muscle perfusion, as determined by single-photon emission computed tomography (SPECT), decreases after breast and/or chest wall (BCW) irradiation. The active breathing coordinator (ABC) enables radiation delivery when the BCW is farther from the heart, thereby decreasing cardiac exposure. We hypothesized that ABC would prevent radiation-induced cardiac toxicity and conducted a randomized controlled trial evaluating myocardial perfusion changes after radiation for left-sided breast cancer with or without ABC. Methods and Materials: Stages I to III left breast cancer patients requiring adjuvant radiation therapy (XRT) were randomized to ABC or No-ABC. Myocardial perfusion was evaluated by SPECT scans (before and 6 months after BCW radiation) using 2 methods: (1) fully automated quantitative polar mapping; and (2) semiquantitative visual assessment. The left ventricle was divided into 20 segments for the polar map and 17 segments for the visual method. Segments were grouped by anatomical rings (apical, mid, basal) or by coronary artery distribution. For the visual method, 2 nuclear medicine physicians, blinded to treatment groups, scored each segment's perfusion. Scores were analyzed with nonparametric tests and linear regression. Results: Between 2006 and 2010, 57 patients were enrolled and 43 were available for analysis. The cohorts were well matched. The apical and left anterior descending coronary artery segments had significant decreases in perfusion on SPECT scans in both ABC and No-ABC cohorts. In unadjusted and adjusted analyses, controlling for pretreatment perfusion score, age, and chemotherapy, ABC was not significantly associated with prevention of perfusion deficits. Conclusions: In this randomized controlled trial, ABC does not appear to prevent radiation-induced cardiac perfusion deficits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Expanding the capability of reaction-diffusion codes using pseudo traps and temperature partitioning: Applied to hydrogen uptake and release from tungsten

Simulating the implantation and thermal desorption evolution in a reaction-diffusion model requires solving a set of coupled differential equations that describe the trapping and release of atomic species in Plasma Facing Materials (PFMs). These fundamental equations are well outlined by the Tritium Migration Analysis Program (TMAP) which can model systems with no more than three active traps per atomic species. To overcome this limitation, we have developed a Pseudo Trap and Temperature Partition (PTTP) scheme allowing us to lump multiple inactive traps into one pseudo trap, simplifying the system of equations to be solved. For all temperatures, we show the trapping of atoms from solute is exactly accounted for when using a pseudo trap. However, a single effective pseudo trap energy can not well replicate the release from multiple traps, each with its own detrapping energy. However, atoms held in a high energy trap will remain trapped at relatively low temperatures, and thus there is a temperature range in which release from high energy traps is effectively inactive. By partitioning the temperature range into segments, a pseudo trap can be defined for each segment to account for multiple high energy traps that are actively trapping but are effectively not releasing atoms. With increasing temperature, as in controlled thermal desorption, the lowest energy trap is nearly emptied and can be removed from the set of coupled equations, while the next higher energy trap becomes an actively releasing trap. Each segment is thus calculated sequentially, with the last time step of a given segment solution being used as an initial input for the next segment as only the pseudo and actively releasing traps are modeled. This PTTP scheme is then applied to experimental thermal desorption data for tungsten (W) samples damaged with heavy ions, which display six distinct release peaks during thermal desorption. Without modifying the TMAP7 source code the PTTP scheme is shown to successfully model the D retention in all six traps. In conclusion, we demonstrate the full reconstruction from the plasma implantation phase through the controlled thermal desorption phase with detrapping energies near 0.9, 1.1, 1.4, 1.7, 1.9 and 2.1 eV for a W sample damaged at room temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-performance multiblock PEMs containing a highly acidic fluorinated-hydrophilic domain for water electrolysis

The present paper describes the design and evaluation of novel hydrophilic–hydrophobic poly(arylene ether sulfone) (PAES) multiblock copolymers for their synergistic effects upon transport properties and their potential use in proton exchange membrane water electrolysis. The multiblock copolymers are prepared via a coupling reaction between (i) a hydrophilic segment consisting of a disulfonated quinone fluorinated biphenyl group that contains fluorine moieties next to the sulfonated groups to increase the acidity, and (ii) hydrophobic segments composed of non-sulfonated biphenyl sulfone to provide dimensional stability. Two different lengths (molecular weights; 5k and 10k, where k represents 10 3 g mol -1 ) of hydrophobic segments are used to investigate the effects of the membrane properties compared with those of Nafion® and PAES random copolymer (i.e., BPSH40). Atomic force microscopy images of the BPSH40 and multiblock membranes are shown to agree closely with a mesoscale simulation, thus confirming the importance of the morphological effect upon the transport properties. Furthermore, the multiblock copolymer with a higher proportion of hydrophilic segments (10 k–5k) was shown to provide enhanced performance (3.41 A cm -2 at 1.9 V) compared to the multiblock copolymer with equal proportions of hydrophilic and hydrophobic segments (10 k–10 k) due to the greater continuity of nano-sized ionic channels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-Consistent Theory for Structural Relaxation, Dynamic Bond Exchange Times, and the Glass Transition in Polymeric Vitrimers

Here, we formulate a statistical mechanical theory for how dynamic bond exchange influences the activated hopping-driven relaxation of Kuhn segments in dynamically cross-linked networks or vitrimers over a wide range of temperatures and cross-link densities. The key new methodological aspect is to address in a self-consistent manner the dynamic consequences of bond exchange on the Kuhn segmental alpha relaxation, and vice versa. The predicted temperature dependence of the segmental alpha time of vitrimers at high temperatures remains the same as that of permanent networks, but at lower temperatures, a significant acceleration of relaxation occurs due to bond exchanges. From a mechanistic perspective, the vitrimer local cage barrier is very weakly affected by bond exchange, while the collective elastic barrier contribution decreases significantly in the deeply supercooled regime. The vitrimer glass transition temperature is predicted to grow linearly with the square root of the cross-link density, as previously found for permanent networks. Material-specific chemical effects such as cross-linker size relative to that of the normal Kuhn segment or special attraction of a cross-linker with polymers are crudely considered based on model calculations. The theory is quantitatively applied to recent experiments on dry ethylene vitrimers. Good agreements are found including that the bond exchange time follows an Arrhenius law at high enough temperatures but upward non-Arrhenius deviations emerge in the deeply supercooled regime, and a collapsed master curve of the segment alpha time exists over a wide range of cross-link densities and temperatures. Possible extensions to treat dynamic heterogeneity effects and penetrant transport in vitrimers are briefly discussed.

chemical calculations↗

In situ visualization of metallurgical reactions in nanoscale Cu/Sn diffusion couples

The Cu–Sn metallurgical soldering reaction in two-segmented Cu–Sn nanowires is visualized by in-situ transmission electron microscopy. By varying the relative lengths of Cu and Sn segments, we show that the metallurgical reaction starts at ~ 200 ° with the formation of a Cu–Sn solid solution for the Sn/Cu length ratio smaller than 1:5 while the formation of Cu–Sn intermetallic compounds (IMCs) for larger Sn/Cu length ratios. Upon heating the nanowires up to ~ 500 °C, two phase transformation pathways occur, η-Cu₆Sn₅ → ε-Cu₃Sn → δ-Cu₄₁Sn₁₁ for nanowires with a long Cu segment and η-Cu₆Sn₅ → ε-Cu₃Sn → γ-Cu₃Sn with a short Cu segment. The dynamic in situ TEM visualization of the evolution of Kirkendall voids demonstrates that Cu diffuses faster both in Sn and IMCs than that of Sn in Cu₃ and IMCs, which is the underlying cause of the dependence of the IMC formation and associated phase evolution on the relative lengths of the Cu and Sn segments.

36 MATERIALS SCIENCE↗

Feedback control of an azimuthal oscillation in the E Multiplication-Sign B discharge of Hall thrusters

Feedback control of a low-frequency azimuthal wave known as a 'rotating spoke' in the E Multiplication-Sign B discharge of a cylindrical Hall thruster was demonstrated. The rotating spoke is an m = 1 azimuthal variation in density, electron temperature, and potential that rotates at about 10% of the local E Multiplication-Sign B electron rotation speed. It causes increased electron transport across the magnetic field and is suspected to be an ionization wave. Feedback control of this wave required special consideration because, although it causes a rotating azimuthal variation in the current density to the anode, it does not show up as a signal in the total thruster discharge current. Therefore, an extra source of information was needed to track the oscillation, which was addressed by using a special anode that was split azimuthally into four segments. The current to each segment oscillates as the rotating spoke passes over it, and feedback is accomplished by resistors connected in series with each anode segment which causes the voltage on a segment to decrease in proportion to the current through that segment. The feedback resulted in the disappearance of a coherent azimuthal wave and a decrease in the time-averaged total discharge current by up to 13.2%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Molecular-dynamics simulations of thin polyisoprene films confined between amorphous silica substrates

Constant temperature–constant pressure (NpT) molecular-dynamics computer simulations have been carried out for the united-atom model of a non-crosslinked (1,4) cis-polyisoprene (PI) melt confined between two amorphous, fully coordinated silica surfaces. The Lennard-Jones 12-6 potential was implemented to describe the polymer–silica interactions. The thickness H of the produced PI–silica film has been varied in a wide range, 1 < H/R{sub g} < 8, where R{sub g} is the individual PI chain radius of gyration measured under the imposed confinement. After a thorough equilibration, the PI film stratified structure and polymer segmental dynamics have been studied. The chain structure in the middle of the films resembles that in a corresponding bulk, but the polymer-density profile shows a pronounced ordering of the polymer segments in the vicinity of silica surfaces; this ordering disappears toward the film middles. Tremendous slowing down of the polymer segmental dynamics has been observed in the film surface layers, with the segmental relaxation more than 150 times slower as compared to that in a PI bulk. This effect increases with decreasing the polymer-film thickness. The segmental relaxation in the PI film middles shows additional relaxation process which is absent in a PI bulk. Even though there are fast relaxation processes in the film middle, its overall relaxation is slower as compared to that in a bulk sample. The interpretation of the results in terms of polymer glassy bridges has been discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonstochastic magnetic reversal in artificial quasicrystalline spin ice

We have measured the isothermal DC magnetization of Penrose P2 tilings (P2T) composed of wire segments of permalloy thin film. Micromagnetic simulations reproduce the coercive fields and “knee anomalies” observed in experimental data and show magnetic shape anisotropy constrains segments to be single-domain (Ising spins) at low fields, similar to artificial spin ice (ASI). Mirror symmetry controls the initial reversal of individual segments oriented parallel to the applied field, followed by complex switching of multiple adjacent segments (“avalanches”) of various orientations such that closed magnetization loops (“vortices”) are favored. Ferromagnetic P2T differ from previously studied ASI systems due to their aperiodic translational symmetry and numerous inequivalent pattern vertices, which drive nonstochastic switching of segment polarizations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Self-oscillating AB diblock copolymer developed by post modification strategy

We prepared AB diblock copolymer composed of hydrophilic poly(ethylene oxide) segment and self-oscillating polymer segment. In the latter segment, ruthenium tris(2,2′-bipyridine) (Ru(bpy){sub 3}), a catalyst of the Belousov-Zhabotinsky reaction, is introduced into the polymer architecture based on N-isopropylacrylamide (NIPAAm). The Ru(bpy){sub 3} was introduced into the polymer segment by two methods; (i) direct random copolymerization (DP) of NIPAAm and Ru(bpy){sub 3} vinyl monomer and (ii) post modification (PM) of Ru(bpy){sub 3} with random copolymer of NIPAAm and N-3-aminopropylmethacrylamide. For both the diblock copolymers, a bistable temperature region (the temperature range; ΔT{sub m}), where the block copolymer self-assembles into micelle at reduced Ru(bpy){sub 3}{sup 2+} state whereas it breaks-up into individual polymer chain at oxidized Ru(bpy){sub 3}{sup 3+} state, monotonically extends as the composition of the Ru(bpy){sub 3} increases. The ΔT{sub m} of the block copolymer prepared by PM is larger than that by DP. The difference in ΔT{sub m} is rationalized from the statistical analysis of the arrangement of the Ru(bpy){sub 3} moiety along the self-oscillating segments. By using the PM method, the well-defined AB diblock copolymer having ΔT{sub m} (ca. 25 °C) large enough to cause stable self-oscillation can be prepared. The periodic structural transition of the diblock copolymer in a dilute solution ([Polymer] = 0.1 wt. %) is closely investigated in terms of the time-resolved dynamic light scattering technique at constant temperature in the bistable region. A macroscopic viscosity oscillation of a concentrated polymer solution (15 wt. %) coupled with the periodic microphase separation is also demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polymer dynamics under cylindrical confinement featuring a locally repulsive surface: A quasielastic neutron scattering study

We investigated the effect of intermediate cylindrical confinement with locally repulsive walls on the segmental and entanglement dynamics of a polymer melt by quasielastic neutron scattering. As a reference, we measured the corresponding polymer melt under identical conditions. The locally repulsive confinement was realized by hydrophilic anodic alumina nanopores with a diameter of 20 nm. The end-to-end distance of the hydrophobic infiltrated polyethylene-alt-propylene was close to this diameter. In the case of hard wall repulsion with negligible local attraction, several simulations predicted an acceleration of segmental dynamics close to the wall. Other than in attractive or neutral systems, where the segmental dynamics is slowed down, we found that the segmental dynamics in the nanopores is identical to the local mobility in the bulk. Even under very careful scrutiny, we could not find any acceleration of the surface-near segmental motion. On the larger time scale, the neutron spin-echo experiment showed that the Rouse relaxation was not altered by confinement effects. Moreover, the entanglement dynamics was not affected. Thus at moderate confinement conditions, facilitated by locally repulsive walls, the dynamics remains as in the bulk melt, a result that is not so clear from simulations.

36 MATERIALS SCIENCE↗

Crystal Structures of Multicopper Oxidase CueO Bound to Copper(I) and Silver(I): Functional Role of a Methonine-Rich Sequence

The multicopper oxidase CueO oxidizes toxic Cu(I) and is required for copper homeostasis in Escherichia coli. Like many proteins involved in copper homeostasis, CueO has a methionine-rich segment that is thought to be critical for copper handling. How such segments function is poorly understood. Here, we report the crystal structure of CueO at 1.1 {angstrom} with the 45-residue methionine-rich segment fully resolved, revealing an N-terminal helical segment with methionine residues juxtaposed for Cu(I) ligation and a C-terminal highly mobile segment rich in methionine and histidine residues. We also report structures of CueO with a C500S mutation, which leads to loss of the T1 copper, and CueO with six methionines changed to serine. Soaking C500S CueO crystals with Cu(I), or wild-type CueO crystals with Ag(I), leads to occupancy of three sites, the previously identified substrate-binding site and two new sites along the methionine-rich helix, involving methionines 358, 362, 368, and 376. Mutation of these residues leads to a {approx}4-fold reduction in kcat for Cu(I) oxidation. Ag(I), which often appears with copper in nature, strongly inhibits CueO oxidase activities in vitro and compromises copper tolerance in vivo, particularly in the absence of the complementary copper efflux cus system. Together, these studies demonstrate a role for the methionine-rich insert of CueO in the binding and oxidation of Cu(I) and highlight the interplay among cue and cus systems in copper and silver homeostasis.

59 BASIC BIOLOGICAL SCIENCES↗

Solar wind density spectra around the ion spectral break

This paper presents a large statistical analysis of ≈5800 frequency spectra of the solar wind density fluctuations in the range 0.001–5 Hz (corresponding to spatial scales of 100–5 × 10{sup 5} km). The analysis confirms that the spectrum consists of three segments divided by two breakpoints and that each of the segments can be described by a power-law function with a spectral index α. The first segment corresponds to MHD scales and is followed by a plateau, and the third segment can be associated with the kinetic range. The statistics show that the values of the spectral slopes depend on the density fluctuations; their increasing amplitude leads to a steepening of each segment. The index of −1.8 can typically be found at MHD scales and averaging of the spectra in the frequency domain leads to an index of −8/3 at kinetic scales, whereas averaging in frequencies normalized to the ion gyrostructure frequency, f{sub g}, defined as the ratio of the solar wind bulk speed and thermal ion gyroradius, provides a value of −7/3. Both breakpoint locations are controlled by the gyrostructure frequency.

79 ASTRONOMY AND ASTROPHYSICS↗

THE CORONAL LOOP INVENTORY PROJECT

Most coronal physicists now seem to agree that loops are composed of tangled magnetic strands and have both isothermal and multithermal cross-field temperature distributions. As yet, however, there is no information on the relative importance of each of these categories, and we do not know how common one is with respect to the other. In this paper, we investigate these temperature properties for all loop segments visible in the 171-Å image of AR 11294, which was observed by the Atmospheric Imaging Assembly (AIA) on 2011 September 15. Our analysis revealed 19 loop segments, but only 2 of these were clearly isothermal. Six additional segments were effectively isothermal, that is, the plasma emission to which AIA is sensitive could not be distinguished from isothermal emission, within measurement uncertainties. One loop had both isothermal transition region and multithermal coronal solutions. Another five loop segments require multithermal plasma to reproduce the AIA observations. The five remaining loop segments could not be separated reliably from the background in the crucial non-171-Å AIA images required for temperature analysis. We hope that the direction of coronal heating models and the efforts modelers spend on various heating scenarios will be influenced by these results.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical methodology for treating static and dynamic dislocation problems near a free surface

Abstract Simulation of dislocation dynamics enables researchers and scientists to explore the plastic behavior of crystalline materials under loading. Analytic solutions for the stress field due to a linear dislocation segment near a free surface are case-specific, e.g. dealing with either a horizontal segment or a vertical segment, and therefore hard to implement in time-dependent dislocation dynamics simulations as different dislocation segments could be differently oriented. This article presents a generalized numerical framework to find the stress field beneath a free surface due to the presence of a dislocation segment. The framework can be expanded to non-flat surfaces. Also, three-dimensional discrete dislocation dynamics simulations are performed here, which clearly show the effect of free surfaces on the flow stress of a material.

Siddique, Abu Bakar↗

Semicoherent search strategy for known continuous wave sources in binary systems

We present a method for detection of weak continuous signals from sources in binary systems via the incoherent combination of many short coherently analyzed segments. The main focus of the work is on the construction of a metric on the parameter space for such signals for use in matched-filter based searches. The metric is defined using a maximum likelihood detection statistic applied to a binary orbit phase model including eccentricity. We find that this metric can be accurately approximated by its diagonal form in the regime where the segment length is << the orbital period. Hence, correlations between parameters are effectively removed by the combination of many independent observations. We find that the ability to distinguish signal parameters is independent of the total semicoherent observation span (for the semicoherent span >> the segment length) for all but the orbital angular frequency. Increased template density for this parameter scales linearly with the observation span. We also present two example search schemes. The first use a reparametrized phase model upon which we compute the metric on individual short coherently analyzed segments. The second assumes long >> the orbital period segment lengths from which we again compute the coherent metric and find it to be approximately diagonal. In this latter case we also show that the semicoherent metric is equal to the coherent metric.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗