Syringe filtration methods for examining dissolved and colloidal trace element distributions in remote field locations

It is well-established that sampling and sample processing can easily introduce contamination into dissolved trace element samples if precautions are not taken. However, work in remote locations sometimes precludes bringing bulky clean lab equipment into the field and likewise may make timely transport of samples to the lab for processing impossible. Straightforward syringe filtration methods are described here for collecting small quantities (15 mL) of 0.45- and 0.02-microm filtered river water in an uncontaminated manner. These filtration methods take advantage of recent advances in analytical capabilities that require only small amounts of waterfor analysis of a suite of dissolved trace elements. Filter clogging and solute rejection artifacts appear to be minimal, although some adsorption of metals and organics does affect the first approximately 10 mL of water passing through the filters. Overall the methods are clean, easy to use, and provide reproducible representations of the dissolved and colloidal fractions of trace elements in river waters. Furthermore, sample processing materials can be prepared well in advance in a clean lab and transported cleanly and compactly to the field. Application of these methods is illustrated with data from remote locations in the Rocky Mountains and along the Yukon River. Evidence from field flow fractionation suggests that the 0.02-microm filters may provide a practical cutoff to distinguish metals associated with small inorganic and organic complexes from those associated with silicate and oxide colloids.

Colloids/analysis↗

Liquefaction of pelleted corn cobs

Liquid slurries at high loadings (pumpable slurries) are critical to handle the streams between the unit operations in a biorefinery. Their liquefaction potential was initially tested with a small-scale method using 3FPU Ctec-2 /g dry biomass, and results were confirmed in 1L bioreactors experiments. Liquid slurries of cobs were observed in small scale tests (based on visual appearance, and reducing sugars released). Results were confirmed in 1L bioreactors under similar experimental conditions. Yield stress value in bioreactor was 34 ± 6Pa at 96 h, and glucan and xylan conversion to glucose and xylose, respectively, were 41 and 21%. In addition, work has been initiated with liquefaction of other pelleted corn stover fractions: Husk/Leaf (A),Husk (B), Stems (D) and controls (whole corn stover; F and G). Compositional analysis of the pellets showed glucan content (%) in the samples ranged from 31.9 to 36.1, xylan from 19.1 to 20.9, total lignin 13.1 to 18.8,and total ash 1.73 to 10.19. The moisture content ranged from 6.21 to 11.66%. Given these similar characteristics, we also examined liquefaction of these other samples, and they also showed that liquid slurries are possible. Work is continuing to define favourable conditions for liquid slurries formation.

Cruz, Antonio↗

Crosslinking of SAVY-4000 O-rings as a Function of Aging Conditions

SAVY-4000 containers were developed as a part of DOE M 441.1-1 to protect workers who handle stored nuclear material from exposure due to loss of containment.1 The SAVY-4000 is comprised of three parts: a lid, a container, and a cross-linked fluoropolymer O-ring. Degradation of the O-ring during use could limit the lifetime of the SAVY-4000. In order to quantify the chemical changes of the Oring over time, the molecular weight between crosslinks was determined as a function of aging conditions using a swelling technique. Because the O-ring is a cross-linked polymer, it will absorb solvent into its matrix without dissolving. The relative amount of solvent uptake can be related to the degree of crosslinking using an equation developed by Paul Flory and John Rehner Jr3. This method was used to analyze O-ring samples aged under thermal and ionizing-radiation conditions. It was found that at the harsher thermal gaining conditions in absence of ionizing-radiation the average molecular weight between crosslinks decreased, indicating a rise in crosslinks, which may be attributable to advanced aging with no ionizing radiation present. Inversely, in the presence of ionizing radiation it was found that material has a higher level of cross-linking with age. This information could be used to help predict the lifetime of the O-rings in SAVY-4000 containers under service conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

International Perspective on the Application of Non-Destructive Assay Technology Platforms for Sentencing and Disposal of Radioactive Waste - 12113

Over the past decade, major technology improvements have been introduced in the field of Non-Destructive Assay (NDA) for the management and disposal of radioactive waste in compliance with an evolving regulatory structure. For example in the United States, various NDA technologies have been successfully developed to meet the stringent characterization requirements of the Department of Energy. The use of this instrumentation, combined with the compliant operational processes and expertise levels that have emerged in parallel, have enabled over 75,000 m{sup 3} (or in excess of 145,000 containers) of contact and remote handled transuranic (TRU) waste to be sentenced to date to the Waste Isolation Pilot Plant from 10 different consignor sites. Many of these techniques have applicability that transcends national borders and can be used for common characterization challenges in waste sentencing and disposal on an international basis. Applicable waste streams could include LLW, ILW, TRU and HLW. There are specific design aspects of assay equipment that must be tailored to meet the applicable regulatory requirements for detection and quantification of a set of nuclides of interest to a prescribed limit of detection and measurement uncertainty. Each host nation will have specific challenges in the form of matrix types and processes, availability of historical information, needs for portable versus fixed instruments and the requirement to measure all containers versus assay of a representative sample. Furthermore, the practice of load management (combining smaller packages into a larger package designed to meet the overall waste acceptance criteria for the bulk container) may not have universal acceptability. An evaluation has been performed on a sample of the most successful technologies that have recently emerged to understand their applicability in other countries. Two types of instrumentation 'suite' are considered for measurements on drums and larger boxes / crates: (i) High Efficiency Neutron Coincidence counting combined with gamma isotopic analysis (e.g. the SuperHENC), and (ii) Portable NDA using neutron slab counters and far field high resolution gamma spectroscopy. Target countries (outside the United States) for these applications are: China, Japan, UK, Sweden and Canada. Specific challenges in each country are addressed and the applicability of the technologies as 'universal platforms' is considered. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Decision Making In A High-Tech World: Automation Bias and Countermeasures

Automated decision aids and decision support systems have become essential tools in many high-tech environments. In aviation, for example, flight management systems computers not only fly the aircraft, but also calculate fuel efficient paths, detect and diagnose system malfunctions and abnormalities, and recommend or carry out decisions. Air Traffic Controllers will soon be utilizing decision support tools to help them predict and detect potential conflicts and to generate clearances. Other fields as disparate as nuclear power plants and medical diagnostics are similarly becoming more and more automated. Ideally, the combination of human decision maker and automated decision aid should result in a high-performing team, maximizing the advantages of additional cognitive and observational power in the decision-making process. In reality, however, the presence of these aids often short-circuits the way that even very experienced decision makers have traditionally handled tasks and made decisions, and introduces opportunities for new decision heuristics and biases. Results of recent research investigating the use of automated aids have indicated the presence of automation bias, that is, errors made when decision makers rely on automated cues as a heuristic replacement for vigilant information seeking and processing. Automation commission errors, i.e., errors made when decision makers inappropriately follow an automated directive, or automation omission errors, i.e., errors made when humans fail to take action or notice a problem because an automated aid fails to inform them, can result from this tendency. Evidence of the tendency to make automation-related omission and commission errors has been found in pilot self reports, in studies using pilots in flight simulations, and in non-flight decision making contexts with student samples. Considerable research has found that increasing social accountability can successfully ameliorate a broad array of cognitive biases and resultant errors. To what extent these effects generalize to performance situations is not yet empirically established. The two studies to be presented represent concurrent efforts, with student and professional pilot samples, to determine the effects of accountability pressures on automation bias and on the verification of the accurate functioning of automated aids. Students (Experiment 1) and commercial pilots (Experiment 2) performed simulated flight tasks using automated aids. In both studies, participants who perceived themselves as accountable for their strategies of interaction with the automation were significantly more likely to verify its correctness, and committed significantly fewer automation-related errors than those who did not report this perception.

Mosier, Kathleen L.↗

Probabilistic Modeling of a Three-Stage Human Landing System Architecture

Unmitigated uncertainties are known to have previously led to failed development programs; in order to combat these uncertainties, risks and their impacts must be understood and handled to ensure program success. In this paper, a probabilistic methodology to handle uncertainties is demonstrated on a three-element Human Landing System (HLS) concept, which allows tracking of current best estimates of the vehicle’s performance and assessment of its robustness against uncertainties. This methodology has two key parts: first, the creation of a dynamic architecture model of a three-element HLS concept; and second, its use with surrogate modeling and range estimating techniques to capture and propagate uncertainties. The DYnamic Rocket EQuation Tool (DYREQT), a space systems synthesis and sizing framework used by NASA, was used as to model the HLS architecture. For the probabilistic analysis, uncertainties of interest within the HLS concept were enumerated and represented as parameters within the DYREQT model as inputs for vehicle stages or mission profile events. Range estimating — a probabilistic method that combines Monte Carlo sampling, focus on critical parameters, and heuristics to assess risk and opportunities — is then adapted with operational parameters as well as vehicle parameters in the DYREQT model to capture mission uncertainty alongside vehicle uncertainty. To perform the range estimation portion of this methodology, the DYREQT model was sampled using a Design of Experiments (DoE) to efficiently explore the architecture design space with respect to the set of uncertainty parameters. Then, the results were used to create surrogate models, multivariate regressions that can visualize hypercube trends in the design space, of the architecture with respect to the uncertainty parameters. Using a correlation matrix constructed for the uncertainty parameters, previously independent samples were transformed to perform a Correlated Monte Carlo on the surrogate models. This probabilistic methodology was proved to provide insight into the underlying uncertainties of the three-element HLS architecture.

Stephanie Y Zhu↗

Probabilistic Modeling of a Three-Stage Human Landing System Architecture

Unmitigated uncertainties are known to have previously led to failed development programs; in order to combat these uncertainties, risks and their impacts must be understood and handled to ensure program success. In this paper, a probabilistic methodology to handle uncertainties is demonstrated on a three-element Human Landing System (HLS) concept, which allows tracking of current best estimates of the vehicle’s performance and assessment of its robustness against uncertainties. This methodology has two key parts: first, the creation of a dynamic architecture model of a three-element HLS concept; and second, its use with surrogate modeling and range estimating techniques to capture and propagate uncertainties. The DYnamic Rocket EQuation Tool (DYREQT), a space systems synthesis and sizing framework used by NASA, was used as to model the HLS architecture. For the probabilistic analysis, uncertainties of interest within the HLS concept were enumerated and represented as parameters within the DYREQT model as inputs for vehicle stages or mission profile events. Range estimating — a probabilistic method that combines Monte Carlo sampling, focus on critical parameters, and heuristics to assess risk and opportunities — is then adapted with operational parameters as well as vehicle parameters in the DYREQT model to capture mission uncertainty alongside vehicle uncertainty. To perform the range estimation portion of this methodology, the DYREQT model was sampled using a Design of Experiments (DoE) to efficiently explore the architecture design space with respect to the set of uncertainty parameters. Then, the results were used to create surrogate models, multivariate regressions that can visualize hypercube trends in the design space, of the architecture with respect to the uncertainty parameters. Using a correlation matrix constructed for the uncertainty parameters, previously independent samples were transformed to perform a Correlated Monte Carlo on the surrogate models. This probabilistic methodology was proved to provide insight into the underlying uncertainties of the three-element HLS architecture.

Stephanie Y. Zhu↗

About a method for compressing X-ray computed microtomography data

The management of scientific data is of high importance especially for experimental techniques that produce big data volumes. Such a technique is x-ray computed tomography (CT) and its community has introduced advanced data formats which allow for better management of experimental data. Rather than the organization of the data and the associated meta-data, the main topic on this work is data compression and its applicability to experimental data collected from a synchrotron-based CT beamline at the Elettra-Sincrotrone Trieste facility (Italy) and studies images acquired from various types of samples. This study covers parallel beam geometry, but it could be easily extended to a cone-beam one. The reconstruction workflow used is the one currently in operation at the beamline. Contrary to standard image compression studies, this manuscript proposes a systematic framework and workflow for the critical examination of different compression techniques and does so by applying it to experimental data. Beyond the methodology framework, this study presents and examines the use of JPEG-XR in combination with HDF5 and TIFF formats providing insights and strategies on data compression and image quality issues that can be used and implemented at other synchrotron facilities and laboratory systems. In conclusion, projection data compression using JPEG-XR appears as a promising, efficient method to reduce data file size and thus to facilitate data handling and image reconstruction

data compression↗

Alpha-Imaging Detector System Development for Large Area Monitoring

Effective management and disposal of legacy nuclear waste are essential for ensuring safe work environments and minimizing environmental impacts. Monitoring airborne actinide contamination is particularly critical due to the high internal dose potential of alpha-emitting radionuclides. Traditional continuous air monitoring systems (CAMs) used in the industry are limited in the volume of air they can sample, potentially leading to inaccurate radiation detection over large areas. For example, in 2018, elevated levels of airborne Plutonium-239 were detected beyond the controlled areas of the Hanford Plutonium Finishing Plant, highlighting the potential risks to both plant workers and nearby residents. To address these challenges, high-efficiency particulate absorbing (HEPA) air purifiers can enhance air flow by up to 1.5 orders of magnitude, thereby increasing monitoring efficiency and providing a cost-effective solution for large-area surveillance. To quantify the activities of alpha-emitting radionuclides on HEPA filters, the Savannah River National Laboratory is developing an advanced alpha-imaging detection system. This system includes scintillating materials combined with a digital scientific camera. A significant concern in operating such a large-area airborne monitoring system is the handling of HEPA filters, which may be contaminated with radioactive particles. To mitigate these hazards, it is crucial to ensure that any contamination is securely fixed onto the filters. Efforts have been made to optimize the sensitivity of scintillator-epoxy composites and apply them to HEPA filters. These materials were characterized using fluoroscence spectroscopy. These techniques confirmed the purity of the raw materials, the dispersion of scintillators in the epoxy matrix, and the stability of their optical and structural properties post-modification. The optimal scintillator-epoxy composite was selected for use on alpha-spiked HEPA filters to evaluate the efficiency of the sprayer. HEPA filters, embedded with alpha particles collected by an air purifier deployed in an airborne radiation area, have been tested to assess detection efficiency. Future work will focus on employing multiple imaging sensors simultaneously to enhance sensitivity across different regions of the HEPA filter.

Pham, Phuong [Savannah River National Laboratory (↗

Examining Nuisance Aerosol Detections in Light of the Origin of the Screening Process (November 2021)

The evolution of philosophy and computations in the International Data Center (IDC) related to aerosol samples have had profound impacts on the number of recorded detections in the network since routine operations began in 2000. Key decisions from policymakers have been the list of triggering radionuclides, the scheme for categorizing these into interest levels 1-5, and an algorithm for determining when an anthropogenic isotope is seen so often that it is no longer interesting, known as the Exponential Weighted Moving Average (EWMA). These are described in the Operations Manual of the IDC. Key parameters that are controlled by the IDC but for which the IDC receives occasional input from policymakers include the constants in EWMA and the peak significance threshold for individual gamma rays, the latter of which directly leads to determination of the presence or absence of a radionuclide in a sample. There are also changes in computations which the IDC makes and informs policy makers about, such as changes in how background is computed, which could also affect the ease of detecting a peak – real or false. Rather than focus on the quantitative changes due to computation changes, this work records some thinking on how isotopes and peak significance levels were chosen, and the resulting detections seen over 18 years during the buildup of the International Monitoring System (IMS). These detections are considered on a global scale to try to determine the relative impact on monitoring, and in some cases, the nature of their existence. Repeated detections of 131I and 133I are the most troublesome, but they are not so frequent to be a major problem for the Verification Regime. These detections could probably be handled adequately using scientific methods currently under development for xenon backgrounds. It is also somewhat problematic that top-level analysis of aerosol backgrounds has not been reported previous to this. The steep increase in the rate of detections after 2016 are a concern, either in the actual backgrounds or from changes in the calculations methods used to generate the Reviewed Radionuclide Report (RRR.) Final conclusions of the authors are that the computational stability of the RRR is very important. With computational stability, changes can be usefully analyzed as being due to changes in radioactivity in Earth’s atmosphere This report is a distillation into text of a talk given in the Radionuclide Experts Group (RNEG) in Vienna during Working Group B (WGB) in February of 2019. This report does not directly contain any IDC data, only summaries by year, or by isotope, or by location. No specific IDC detection by time, location, or isotope is included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rules and management of biomedical waste at Vivekananda Polyclinic: A case study

Hospitals and other healthcare establishments have a 'duty of care' for the environment and for public health, and have particular responsibilities in relation to the waste they produce (i.e., biomedical waste). Negligence, in terms of biomedical waste management, significantly contributes to polluting the environment, affects the health of human beings, and depletes natural and financial resources. In India, in view of the serious situation of biomedical waste management, the Ministry of Environment and Forests, within the Government of India, ratified the Biomedical Waste (Management and Handling) Rules, in July 1998. The present paper provides a brief description of the biomedical waste (Management and Handling) Rules 1998, and the current biomedical waste management practices in one of the premier healthcare establishments of Lucknow, the Vivekananda Polyclinic. The objective in undertaking this study was to analyse the biomedical waste management system, including policy, practice (i.e., storage, collection, transportation and disposal), and compliance with the standards prescribed under the regulatory framework. The analysis consisted of interviews with medical authorities, doctors, and paramedical staff involved in the management of the biomedical wastes in the Polyclinic. Other important stakeholders that were consulted and interviewed included environmental engineers (looking after the Biomedical Waste Cell) of the State Pollution Control Board, and randomly selected patients and visitors to the Polyclinic. A general survey of the facilities of the Polyclinic was undertaken to ascertain the efficacy of the implemented measures. The waste was quantified based on random samples collected from each ward. It was found that, although the Polyclinic in general abides by the prescribed regulations for the treatment and disposal of biomedical waste, there is a need to further build the capacity of the Polyclinic and its staff in terms of providing state-of-the-art facilities and on-going training in order to develop a model biomedical waste management system in the Polyclinic. There is also a need to create awareness among all other stakeholders about the importance of biomedical waste management and related regulations. Furthermore, healthcare waste management should go beyond data compilation, enforcement of regulations, and acquisition of better equipment. It should be supported through appropriate education, training, and the commitment of the healthcare staff and management and healthcare managers within an effective policy and legislative framework.

54 ENVIRONMENTAL SCIENCES↗

Deployable Aeroshell Flexible Thermal Protection System Testing

Deployable aeroshells offer the promise of achieving larger aeroshell surface areas for entry vehicles than otherwise attainable without deployment. With the larger surface area comes the ability to decelerate high-mass entry vehicles at relatively low ballistic coefficients. However, for an aeroshell to perform even at the low ballistic coefficients attainable with deployable aeroshells, a flexible thermal protection system (TPS) is required that is capable of surviving reasonably high heat flux and durable enough to survive the rigors of construction handling, high density packing, deployment, aerodynamic loading and aerothermal heating. The Program for the Advancement of Inflatable Decelerators for Atmospheric Entry (PAIDAE) is tasked with developing the technologies required to increase the technology readiness level (TRL) of inflatable deployable aeroshells, and one of several of the technologies PAIDAE is developing for use on inflatable aeroshells is flexible TPS. Several flexible TPS layups were designed, based on commercially available materials, and tested in NASA Langley Research Center's 8 Foot High Temperature Tunnel (8ft HTT). The TPS layups were designed for, and tested at three different conditions that are representative of conditions seen in entry simulation analyses of inflatable aeroshell concepts. Two conditions were produced in a single run with a sting-mounted dual wedge test fixture. The dual wedge test fixture had one row of sample mounting locations (forward) at about half the running length of the top surface of the wedge. At about two thirds of the running length of the wedge, a second test surface drafted up at five degrees relative to the first test surface established the remaining running length of the wedge test fixture. A second row of sample mounting locations (aft) was positioned in the middle of the running length of the second test surface. Once the desired flow conditions were established in the test section the dual wedge test fixture, oriented at 5 degrees angle of attack down, was injected into the flow. In this configuration the aft sample mounting location was subjected to roughly twice the heat flux and surface pressure of the forward mounting location. The tunnel was run at two different conditions for the test series: 1) 'Low Pressure', and 2) 'High Pressure'. At 'Low Pressure' conditions the TPS layups were tested at 6W/cm2 and 11W/cm2 while at 'High Pressure' conditions the TPS layups were tested at 11W/cm2 and 20W/cm2. This paper details the test configuration of the TPS samples in the 8Ft HTT, the sample holder assembly, TPS sample layup construction, sample instrumentation, results from this testing, as well as lessons learned.

Hughes, Stephen J.↗

Flux Estimation of a PuBe source using Delayed Gamma Neutron Activation Analysis

For handling and storage of a highly radioactive source, it is necessary to have an accurate knowledge of the radioactive source as well as the neutron flux. Recently, due to radiation safety requirements, a PuBe alpha-neutron source at an activation facility at IIT-Kanpur had to be taken out of its original damaged howitzer and placed inside a new shielded container. While, this effort was successful in reducing the radiation dose, and making the setup safe for laboratory measurements, the new source moderator configuration left the new Pu-Be source spectrum unknown. Therefore, in this work we have used delayed gamma neutron activation analysis (DGNAA) of aluminum, copper, iron, manganese (found in iron), and silver for thermal neutron flux estimation of the Pu-Be neutron source. A series of DGNAA measurements with different samples were carried out to find the value of the average thermal neutron flux of a Pu-Be neutron source at Indian Institute of Technology-Kanpur. The order of the thermal neutron flux is found to be nearly 1.64 x 10{sup 5} excluding aluminum. Upon including aluminum, the value of thermal neutron flux decreases to 1.57x10{sup 5}. We have used common metals (like aluminum, silver, copper and iron) to calculate the thermal neutron flux. The calculated value of the thermal neutron flux is consistent for all the metals except for iron. Iron is giving a value almost four times larger than the average calculated value of the thermal neutron flux using other six samples. The reason is currently being investigated. The DGNAA technique came out to be a very useful technique. Now that we know the thermal neutron flux of the Pu-Be source, our future work will include improving the safety and shielding calculations for our activation facility at IIT-Kanpur. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Error statistics and scalability of quantum error mitigation formulas

Quantum computing promises advantages over classical computing in many problems. Nevertheless, noise in quantum devices prevents most quantum algorithms from achieving the quantum advantage. Quantum error mitigation provides a variety of protocols to handle such noise using minimal qubit resources. While some of those protocols have been implemented in experiments for a few qubits, it remains unclear whether error mitigation will be effective in quantum circuits with tens to hundreds of qubits. In this paper, we apply statistics principles to quantum error mitigation and analyse the scaling behaviour of its intrinsic error. We find that the error increases linearly O(ϵN) with the gate number N before mitigation and sublinearly O(ϵ'N γ ) after mitigation, where γ ≈ 0.5, ϵ is the error rate of a quantum gate, and ϵ' is a protocol-dependent factor. The $\sqrt{N}$ scaling is a consequence of the law of large numbers, and it indicates that error mitigation can suppress the error by a larger factor in larger circuits. We propose the importance Clifford sampling as a key technique for error mitigation in large circuits to obtain this result.

97 MATHEMATICS AND COMPUTING↗

F-Hash: Feature-Based Hash Design for Time-Varying Volume Visualization via Multi-Resolution Tesseract Encoding

Interactive time-varying volume visualization is challenging due to its complex spatiotemporal features and sheer size of the dataset. Recent works transform the original discrete time-varying volumetric data into continuous Implicit Neural Representations (INR) to address the issues of compression, rendering, and super-resolution in both spatial and temporal domains. However, training the INR takes a long time to converge, especially when handling large-scale time-varying volumetric datasets. In this work, we proposed F-Hash, a novel feature-based multi-resolution Tesseract encoding architecture to greatly enhance the convergence speed compared with existing input encoding methods for modeling time-varying volumetric data. The proposed design incorporates multi-level collision-free hash functions that map dynamic 4D multi-resolution embedding grids without bucket waste, achieving high encoding capacity with compact encoding parameters. Our encoding method is agnostic to time-varying feature detection methods, making it a unified encoding solution for feature tracking and evolution visualization. Experiments show the F-Hash achieves state-of-the-art convergence speed in training various time-varying volumetric datasets for diverse features. We also proposed an adaptive ray marching algorithm to optimize the sample streaming for faster rendering of the time-varying neural representation.

deep learning↗

High fidelity blade-resolved and actuator line data from a 16 turbine wind farm simulation using ExaWind

This data was generated with the ExaWind code suite (https://github.com/Exawind) as a demonstration of a large, 16 turbine wind farm simulation, calculated using two different levels of fidelity. The lower level of fidelity approach uses an actuator line approach to represent the turbines, and was simulated with AMR-Wind (https://github.com/Exawind/amr-wind/) as the background flow solver, coupled to OpenFAST (https://github.com/OpenFAST/openfast). The higher level of fidelity simulation uses a blade-resolved approach, and is done using AMR-Wind, Nalu-Wind (https://github.com/Exawind/nalu-wind), OpenFAST, and TIOGA (https://github.com/Exawind/tioga). In the blade-resolved simulation, ExaWind couples together a background flow solver, AMR-Wind, and a near-body solver, Nalu-Wind, through an overset technique from the TIOGA application. OpenFAST handles the structural dynamics of the turbine blades and towers, which informs the fluid-structure interaction of the wind turbines with the flow solvers. In the actuator line simulation, a mesh of 295M elements was used for a 5km x 5km domain, and it was simulated using 256 nodes (2048 GPU's) on the Oak Ridge Leadership Computing Facility Frontier supercomputer. For the blade-resolved simulation, 1.5B element mesh was used in the AMR-Wind background 5km x 5km domain, and 16M elements were used for each turbine in the Nalu-Wind domains, for a total of 1.7B elements. This was simulated using 384 nodes on Frontier, with each node using 56 cores for Nalu-Wind and 8 GPU cores. The data in this archive includes the turbine outputs from OpenFAST, 2D sampling planes from AMR-Wind, and full-field solution files from AMR-Wind and Nalu-Wind.

17 WIND ENERGY↗

Phase Behavior of the Ternary NaCl-PuCl 3 -Pu Molten Salt

There is a gap in our understanding of the behavior of fused and molten fuel salts containing unavoidable contamination, such as those due to fabrication, handling, or storage. Therefore, this work used calorimetry to investigate the change in liquidus temperature of PuCl 3 , having an unknown purity and that had been in storage for several decades. Further research was performed by additions of NaCl, making several compositions within the binary system, and summarizing the resulting changes, if any, to the phase diagram. The melting temperature of the PuCl 3 was determined to be 746.5°C, approximately 20°C lower than literature reported values, most likely due to an excess of Pu metal in the PuCl 3 either due to the presence of metallic plutonium remaining from incomplete chlorination or due to the solubility of Pu in PuCl 3 . From the melting temperature, it was determined that the PuCl 3 contained between 5.9 to 6.2mol% Pu metal. Analysis of the NaCl-PuCl 3 samples showed that using the Pu rich PuCl 3 resulted in significant changes to the NaCl-PuCl 3 phase diagram. Most notably an unreported phase transition occurring at approximately 406°C and a new eutectic composition of 52.7mol% NaCl–38.7mol% PuCl 3 –2.5mol% Pu which melted at 449.3°C. Additionally, an increase in the liquidus temperatures was seen for NaCl rich compositions while lower liquidus temperatures were seen for PuCl 3 rich compositions. It can therefore be concluded that changes will occur in the NaCl-PuCl 3 binary system when using PuCl 3 with excess Pu metal. However, melting temperature analysis can provide valuable insight into the composition of the PuCl 3 and therefore the NaCl-PuCl 3 system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wide Temperature Core Loss Characteristics of Transverse Magnetically Annealed Amorphous Tapes for High Frequency Aerospace Magnetics

100 kHz core loss properties of sample transverse magnetically annealed, cobalt-based amorphous and iron-based nanocrystalline tape wound magnetic cores are presented over the temperature range of -150 C to 150 C, at selected values of B(sub peak). For B-fields not close to saturation, the core loss is not sensitive to temperature in this range and is as low as seen in the best MnZn power ferrites at their optimum temperatures. Frequency resolved characteristics are given over the range of 50 kHz to 1 MHz, but at B(sub peak) = 0.1 T and 50 C only. For example, the 100 kHz specific core loss ranged from 50 - 70 mW/cubic cm for the 3 materials, when measured at 0.1 T and 50 C. This very low high frequency core loss, together with near zero saturation magnetostriction and insensitivity to rough handling, makes these amorphous ribbons strong candidates for power magnetics applications in wide temperature aerospace environments.