WE-EF-207-10: Striped Ratio Grids: A New Concept for Scatter Estimation

Purpose: To propose a new method for estimating scatter in x-ray imaging. We propose the “striped ratio grid,” an anti-scatter grid with alternating stripes of high scatter rejection (attained, for example, by high grid ratio) and low scatter rejection. To minimize artifacts, stripes are oriented parallel to the direction of the ramp filter. Signal discontinuities at the boundaries between stripes provide information on local scatter content, although these discontinuities are contaminated by variation in primary radiation. Methods: We emulated a striped ratio grid by imaging phantoms with two sequential CT scans, one with and one without a conventional grid, and processed them together to mimic a striped ratio grid. Two phantoms were scanned with the emulated striped ratio grid and compared with a conventional anti-scatter grid and a fan-beam acquisition, which served as ground truth. A nonlinear image processing algorithm was developed to mitigate the problem of primary variation. Results: The emulated striped ratio grid reduced scatter more effectively than the conventional grid alone. Contrast is thereby improved in projection imaging. In CT imaging, cupping is markedly reduced. Artifacts introduced by the striped ratio grid appear to be minimal. Conclusion: Striped ratio grids could be a simple and effective evolution of conventional anti-scatter grids. Unlike several other approaches currently under investigation for scatter management, striped ratio grids require minimal computation, little new hardware (at least for systems which already use removable grids) and impose few assumptions on the nature of the object being scanned.

60 APPLIED LIFE SCIENCES↗

The future of scientific workflows

Today’s computational, experimental, and observational sciences rely on computations that involve many related tasks. The success of a scientific mission often hinges on the computer automation of these workflows. In April 2015, the US Department of Energy (DOE) invited a diverse group of domain and computer scientists from national laboratories supported by the Office of Science, the National Nuclear Security Administration, from industry, and from academia to review the workflow requirements of DOE’s science and national security missions, to assess the current state of the art in science workflows, to understand the impact of emerging extreme-scale computing systems on those workflows, and to develop requirements for automated workflow management in future and existing environments. Here, this paper is a summary of the opinions of over 50 leading researchers attending this workshop. We highlight use cases, computing systems, workflow needs and conclude by summarizing the remaining challenges this community sees that inhibit large-scale scientific workflows from becoming a mainstream tool for extreme-scale science.

97 MATHEMATICS AND COMPUTING↗

An intra-node HPC network architecture with nanosecond-scale photonic switches

We propose a single-stage network architecture for intra-node connectivity that makes use of nanosecond-scale photonic switches. Although buffering at the switch points is of vital importance for complex multi-stage networks, this is not the case for smaller-scale single-stage networks where the end nodes are located only one hop apart. By limiting the buffering to the end points, the proposed architecture manages to minimize the required electro-optic and opto-electronic conversions, leading in this way to both low end-to-end latency and better energy efficiency. Combining these advantages with nanosecond-scale switching times can allow for high-throughput operation even for frequent switch reconfigurations. The performance of the proposed architecture is evaluated via discrete-event simulations for a wide range of synthetic-traffic cases. The simulation results show that high-throughput operation of ≥90% can be achieved even for small message sizes, i.e., 32 KB for all-to-all communication and 2 KB for uniform random traffic, at a data rate of 400 Gb/s and a switch reconfiguration time of ≤72 ns. Moreover, if 100-ns reconfiguration times are achievable as opposed to 150-ns, then for the all-to-all traffic case a 16% and 28% reduction in completion time can be achieved for message sizes of 8 KB and 1 KB, respectively. In a forthcoming era of optically interfaced processors and accelerators, nanosecond-scale photonic switches appear as a highly promising solution for keeping up with the intra-node bandwidth scaling due to their high-bandwidth, low-latency and fast-switching capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ten–Year Assessment Encourages No–Till for Corn Grain and Stover Harvest

Developing a bio-economy by harvesting crop residues from highly productive corn (Zea mays L.) cropping systems requires science-based management decisions to maintain or enhance grain yield and soil, water, and air resources. Which tillage and stover harvest practices are best for accomplishing these goals? Continuous corn grain yield response to either no-till or chisel plowing with two stover harvest rates (3.4 or 5.1 Mg ha -1 yr -1 ) was evaluated for 10 yr in central Iowa. Each tillage and stover removal combination was replicated four times. Year-to-year variation affected grain yield more than tillage practice (0.2 Mg ha -1 ) or stover removal (0.1 Mg ha -1 ). Grain yields were not statistically different (p = 0.33) between tillage systems. Including machinery costs made return on investment for chisel plow and no-till equivalent even though no-till yields were numerically lower. Net stover income per megagram was US $\$2$ to $\$4$ greater at the 3.4 versus 5.1 Mg ha -1 harvest rate because of more efficient harvesting. Among the four practices, no-till with 3.4 Mg ha -1 stover harvest met multiple goals, including providing acceptable corn grain yields, positive net income per megagram stover, and sufficient residues to protect the soil.

54 ENVIRONMENTAL SCIENCES↗

Materials and Security Consolidation Complex Facilities Radioactive Waste Management Basis and DOE Manual 435.1-1 Compliance Tables

Department of Energy Order 435.1, 'Radioactive Waste Management,' along with its associated manual and guidance, requires development and maintenance of a radioactive waste management basis for each radioactive waste management facility, operation, and activity. This document presents a radioactive waste management basis for Idaho National Laboratory's Materials and Security Consolidation Center facilities that manage radioactive waste. The radioactive waste management basis for a facility comprises existing laboratory-wide and facility-specific documents. Department of Energy Manual 435.1-1, 'Radioactive Waste Management Manual,' facility compliance tables also are presented for the facilities. The tables serve as a tool for developing the radioactive waste management basis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Test Reactor Complex Facilities Radioactive Waste Management Basis and DOE Manual 435.1-1 Compliance Tables

U.S. Department of Energy Order 435.1, 'Radioactive Waste Management,' along with its associated manual and guidance, requires development and maintenance of a radioactive waste management basis for each radioactive waste management facility, operation, and activity. This document presents a radioactive waste management basis for Idaho National Laboratory's Advanced Test Reactor Complex facilities that manage radioactive waste. The radioactive waste management basis for a facility comprises existing laboratory-wide and facility-specific documents. U.S. Department of Energy Manual 435.1-1, 'Radioactive Waste Management Manual,' facility compliance tables also are presented for the facilities. The tables serve as a tool to develop the radioactive waste management basis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Research and Education Campus Facilities Radioactive Waste Management Basis and DOE Manual 435.1-1 Compliance Tables

U.S. Department of Energy Order 435.1, 'Radioactive Waste Management,' along with its associated manual and guidance, requires development and maintenance of a radioactive waste management basis for each radioactive waste management facility, operation, and activity. This document presents a radioactive waste management basis for Idaho National Laboratory Research and Education Campus facilities that manage radioactive waste. The radioactive waste management basis for a facility comprises existing laboratory-wide and facility-specific documents. Department of Energy Manual 435.1-1, 'Radioactive Waste Management Manual,' facility compliance tables also are presented for the facilities. The tables serve as a tool to develop the radioactive waste management basis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Materials and Fuels Complex Facilities Radioactive Waste Management Basis and DOE Manual 435.1-1 Compliance Tables

Department of Energy Order 435.1, 'Radioactive Waste Management,' along with its associated manual and guidance, requires development and maintenance of a radioactive waste management basis for each radioactive waste management facility, operation, and activity. This document presents a radioactive waste management basis for Idaho National Laboratory's Materials and Fuels Complex facilities that manage radioactive waste. The radioactive waste management basis for a facility comprises existing laboratory-wide and facility-specific documents. Department of Energy Manual 435.1-1, 'Radioactive Waste Management Manual,' facility compliance tables also are presented for the facilities. The tables serve as a tool for developing the radioactive waste management basis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Central Facilities Area Facilities Radioactive Waste Management Basis and DOE Manual 435.1-1 Compliance Tables

Department of Energy Order 435.1, 'Radioactive Waste Management,' along with its associated manual and guidance, requires development and maintenance of a radioactive waste management basis for each radioactive waste management facility, operation, and activity. This document presents a radioactive waste management basis for Idaho National Laboratory's Central Facilities Area facilities that manage radioactive waste. The radioactive waste management basis for a facility comprises existing laboratory-wide and facilityspecific documents. Department of Energy Manual 435.1-1, 'Radioactive Waste Management Manual,' facility compliance tables also are presented for the facilities. The tables serve as a tool for developing the radioactive waste management basis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dry Cask Storage Inspection and Monitoring. Interim Report.

Recently, the U.S. Nuclear Regulatory Commission (NRC) issued the guidance on the aging management of dry storage facilities that indicates the necessity to monitor the conditions of dry cask storage systems (DCSSs) over extended periods of time.1 Part of the justification of the aging management plans is the requirement for inspection and monitoring to verify whether continued monitoring, inspection or mitigation are necessary. To meet this challenge Argonne National Laboratory (ANL) in collaboration with Idaho National Laboratory (INL) is conducting scoping studies on current and emerging nondestructive evaluation/examination (NDE) and online monitoring (OLM) technologies for DCSS integrity assessments. The scope of work plan includes identification and verification of technologies for long-term online monitoring of DCSSs’ crucial physical parameters such as temperature, pressure, leakage and structural integrity in general. Modifications have been made to the current technologies to accommodate field inspections and monitoring. A summary of the scoping studies and experimental efforts conducted to date as well as plans for future activities is provided below.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Recovery Act: Innovative CO 2 Sequestration from Flue Gas Using Industrial Sources and Innovative Concept for Beneficial CO 2 Use

The overall goal of this DOE Phase 2 project was to further develop and conduct pilot-scale and field testing of a biomimetic in-duct scrubbing system for the capture of gaseous CO 2 coupled with sequestration of captured carbon by carbonation of alkaline industrial wastes. The Phase 2 project, reported on here, combined efforts in enzyme development, scrubber optimization, and sequestrant evaluations to perform an economic feasibility study of technology deployment. The optimization of carbonic anhydrase (CA) enzyme reactivity and stability are critical steps in deployment of this technology. A variety of CA enzyme variants were evaluated for reactivity and stability in both bench scale and in laboratory pilot scale testing to determine current limits in enzyme performance. Optimization of scrubber design allowed for improved process economics while maintaining desired capture efficiencies. A range of configurations, materials, and operating conditions were examined at the Alcoa Technical Center on a pilot scale scrubber. This work indicated that a cross current flow utilizing a specialized gas-liquid contactor offered the lowest system operating energy. Various industrial waste materials were evaluated as sources of alkalinity for the scrubber feed solution and as sources of calcium for precipitation of carbonate. Solids were mixed with a simulated sodium bicarbonate scrubber blowdown to comparatively examine reactivity. Supernatant solutions and post-test solids were analyzed to quantify and model the sequestration reactions. The best performing solids were found to sequester between 2.3 and 2.9 moles of CO 2 per kg of dry solid in 1-4 hours of reaction time. These best performing solids were cement kiln dust, circulating dry scrubber ash, and spray dryer absorber ash. A techno-economic analysis was performed to evaluate the commercial viability of the proposed carbon capture and sequestration process in full-scale at an aluminum smelter and a refinery location. For both cases the in-duct scrubber technology was compared to traditional amine- based capture. Incorporation of the laboratory results showed that for the application at the aluminum smelter, the in-duct scrubber system is more economical than traditional methods. However, the reverse is true for the refinery case, where the bauxite residue is not effective enough as a sequestrant, combined with challenges related to contaminants in the bauxite residue accumulating in and fouling the scrubber absorbent. Sensitivity analyses showed that the critical variables by which process economics could be improved are enzyme concentration, efficiency, and half-life. At the end of the first part of the Phase 2 project, a gate review (DOE Decision Zero Gate Point) was conducted to decide on the next stages of the project. The original plan was to follow the pre-testing phase with a detailed design for the field testing. Unfavorable process economics, however, resulted in a decision to conclude the project before moving to field testing. It is noted that CO 2 Solutions proposed an initial solution to reduce process costs through more advanced enzyme management, however, DOE program requirements restricting any technology development extending beyond 2014 as commercial deployment timeline did not allow this solution to be undertaken.

Dando, Neal↗

LL-08 Electronic Data Storage Devices100818

To ensure that information security requirements are met, line managers and custodians of electronic data storage devices need to be aware of and compliant with their responsibilities.

97 MATHEMATICS AND COMPUTING↗

Exe-Guard Project

The exe-Guard Project is an alliance between Dominion Virginia Power (DVP), Sandia National Laboratories (SNL), Dartmouth University, and Schweitzer Engineering Laboratories (SEL). SEL is primary recipient on this project. The exe-Guard project was selected for award under DE-FOA-0000359 with CFDA number 81.122 to address Topic Area of Interest 4: Hardened platforms and Systems. The exe-Guard project developed an antivirus solution for control system embedded devices to prevent the execution of unauthorized code and maintain settings and configuration integrity. This project created a white list antivirus solution for control systems capable of running on embedded Linux® operating systems. White list antivirus methods allow only credible programs to run through the use of digital signatures and hash functions. Once a system’s secure state is baselined, white list antivirus software denies deviations from that state because of the installation of malicious code as this changes hash results. Black list antivirus software has been effective in traditional IT environments but has negative implications for control systems. Black list antivirus uses pattern matching and behavioral analysis to identify system threats while relying on regular updates to the signature file and recurrent system scanning. Black list antivirus is vulnerable to zero day exploits which have not yet been incorporated into a signature file update. System scans hamper the performance of high availability applications, as revealed in NIST special publication 1058 which summarizes the impact of blacklist antivirus on control systems: Manual or “on-demand” scanning has a major effect on control processes in that they take CPU time needed by the control process (Sometimes close to 100% of CPU time). Minimizing the antivirus software throttle setting will reduce but not eliminate this effect. Signature updates can also take up to 100% of CPU time, but for a much shorter period than a typical manual scanning process. Control systems are vulnerable to performance losses if off-the-shelf blacklist antivirus solutions aren’t implemented with care. This investment in configuration in addition to constant decommissioning to perform manual signature file updates is unprecedented and impractical. Additionally, control systems are often disconnected or islanded from the network making the delivery of signature updates difficult. Exe-Guard project developed a white list antivirus solution that mitigated the above drawbacks and allows control systems to cost-effectively apply malware protection while maintaining high reliability. The application of security patches can also be minimized since white listing maintains constant defense against unauthorized code execution. Security patches can instead be applied in less frequent intervals where system decommissioning can be scheduled and planned for. Since control systems are less dynamic than IT environments, the feasibility of maintaining a secure baselined state is more practical. Because upgrades are performed in infrequent, calculated intervals, it allows a new security baseline to be established before the system is returned to service. Exe-Guard built on the efforts of SNL under the Code Seal project. SNL demonstrated prototype Trust Anchors on the project which are independent monitoring and control devices that can be integrated into untrustworthy components. The exe-Guard team started with the lessons learned under this project then designed commercial solution for white list malware protection. Malware is a real threat, even on islanded or un-networked installations, since operators can unintentionally install infected files, plug in infected mass storage devices, or infect a piece of equipment on the islanded local area network that can then spread to other connected equipment. Protection at the device level is one of the last layers of defense in a security-in-depth defense model before an asset becomes compromised. This project provided non-destructive intrusion, isolation and automated response solution, achieving a goal of the Department of Energy (DOE) Roadmap to Secure Control Systems. It also addressed CIP-007-R4 which requires asset owners to employ malicious software prevention tools on assets within the electronic security perimeter. In addition, the CIP-007-R3 requirement for security patch management is minimized because white listing narrows the impact of vulnerabilities and patch releases. The exe-Guard Project completed all tasks identified in the statement of project objective and identified additional tasks within scope that were performed and completed within the original budget. The cost share was met and all deliverables were successfully completed and submitted on time. Most importantly the technology developed and commercialized under this project has been adopted by the Energy sector and thousands of devices with exe-Guard technology integrated in them have now been deployed and are protecting our power systems today

24 POWER TRANSMISSION AND DISTRIBUTION↗

Foundational Report Series: Advanced Distribution Management Systems for Grid Modernization, Business Case Calculations for DMS

Distribution Management System (DMS) applications require a substantial commitment of technical and financial resources. In order to proceed beyond limited-scale demonstration projects, utilities must have a clear understanding of the business case for committing these resources that recognizes the total cost of ownership. Many of the benefits provided by investments in DMSs do not translate easily into monetary terms, making cost-benefit calculations difficult. For example, Fault Location Isolation and Service Restoration (FLISR) can significantly reduce customer outage duration and improve reliability. However, there is no well-established and universally-accepted procedure for converting these benefits into monetary terms that can be compared directly to investment costs. This report presents a methodology to analyze the benefits and costs of DMS applications as fundamental to the business case.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Utilizing Open Source Software to Manage Training

At Jefferson Lab, Moodle, an Open-Source Course Management System has been used to produce a comprehensive web-based training program for accelerator operators and crew chiefs. The system is simple to use, self-paced, completely trackable, and able to tie into the lab's overall training infrastructure. Moodle serves as the on-line engine that ties together a variety of new and existing materials, including multimedia, and makes the training system manageable without large manpower requirements. This poster session shows how experienced crew chiefs, operators, and system experts create the courses, what the students see as they learn, and how the training each student has received is quantified and tracked.

Vasilauskis, Paul↗

"Safety First: Though on the Other Hand, Time is Critical”

This talk describes the deployment of research-quality software and hardware for open-road driving experiments by fleets of vehicles. Technological advancements in single-vehicle autonomy have expanded beyond the academic community, and are driven largely by industry stakeholders and manufacturers. However, as the penetration rate of cars with advanced driver assistance features increases, the impact on emergent behavior in traffic is still unknown. Compelling reasons to experiment within open-road conditions must be considered alongside the technical and human factor safety issues in deploying experimental controllers. This is even more challenging when it is necessary to deploy experimental fleets at scale. The talk will describe approaches for co-design of a research testbed for societal-scale systems. Discussion is devoted to the research-quality data gathering and control layers and their technical implementation, the different interfaces for experts in other fields to use these testbeds for research without violating safety requirements, and process and management considerations when deploying the platforms at scale when considering training time and operation complexity of human operators.

Sprinkle, Jonathan↗

Approach to Startup Inventory for Viable Commercial Power Plant

Summary • FPP realization within the next 10-15 years will require dedicated efforts to improve DIR, burn fraction, fueling efficiency, and/or processing times. • Modest improvements from either the fuel cycle side or plasma physics side should be possible with considered allocation of R&D funding. • Current gaps in particular include blanket extraction at scale, improved efficiency in isotope separation and detritiation, and maximizing DIR efficiency. • Total costs for FPP construction and commissioning depend heavily on site regulation, so decreases in required SI and OI can lead to large decreases in capital outlay. • Some subsystems in the fuel cycle are required from a environmental management perspective but are both energetically expensive and time consuming, particularly water detritiation. • Low inventories but high capital and operational costs mean a centralized water detritiation plant could greatly improve likelihood of deployment of multiple FPPs on the same time scale.

MALONE, COLLIN↗

Implementation and Operation of Power Flow Control Solutions for Transmission Systems

Power-flow controls (PFCs) technologies provide a suite of alternatives to more-efficiently direct the flow of power on the grid, improving flexibility and enabling the grid to be more responsive and resilient. PFCs can be used in many cases to mitigate overloads and consequently defer the installation of grid-expansion projects. They can also be suitable options in situations where new transmission lines cannot be built because of environmental constraints, land use, or other types of restrictions. Other uses include mitigation of loop or unintended flows, forcing of contractual or scheduled flows, reduction of congestion, and mitigation solutions during large maintenance or construction projects. While many studies have demonstrated the potential economic benefits of PFC for different types of applications, the implementation implications of using multiple PFCs for system operation and reliability have not been analyzed in detail. The lack of information and practical experience on these aspects hinders adoption of this technology. One use case would be that multiple PFCs are required to coordinate congestion management. In such cases, multiple PFCs are deployed in a meshed power system to control power flows across a wide area. The challenges are associated with PFC interaction—namely, the self and mutual power-flow sensitivity of each PFC, which must be accounted for in the calculation of the respective operating setpoints. This report analyzes implementation and operation that must be considered in evaluating transmission solutions using PFCs. The report first analyzes attributes with which PFC-based solutions should comply, based on the objective and characteristics of each particular use case. It then describes different approaches for coordinated control of multiple PFC devices for different applications, including options to avoid adverse interactions and reduce risks due to inappropriate coordination. Control and operation are illustrated through case studies performed on both generic and actual power system models. This report provides insights for transmission planners and operation engineers about the implementation of PFC-based transmission solutions; consequently, it will help them make informed decisions about the adoption of the technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗