Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Panel Session 11: Featured Country Canada - Remediation of Contaminated Sites

Canada has several unique sites requiring environmental remediation of radiological contaminants. This panel was designed to outline the remediation of contaminated sites across Canada from several perspectives. Remote legacy uranium mining operations, small scale residential locations, and large impacted soil sites all pose different challenges, however there are some common solutions and keys to success. This panel addressed several of those challenges and provided lessons learned on how to successfully plan and execute large scale environmental remediation in both remote and residential locations. This panel focused on the cleaning up several contaminated sites in Canada and monitoring the long-term performance of sites that have already been remediated. Panelists addressed the technical and social challenges associated with various cleanup initiatives North of the 49. Parallel and the solutions that have been adopted to enable these projects to move forward. The panel offered the perspectives of owners, contractors and regulators on current projects and how they are leveraging past experience and learning from others to ensure future undertakings are successful. Presentations proposed include: 1 - Regulating Environmental Remediation in Canada (Michael Rinker, Canadian Nuclear Safety Commission (Canada)); 2 - Integration of Local Knowledge and Engagement/Capacity Building Legacy Uranium Mine Sites (Joe Muldoon, Saskatchewan Research Council (Canada)); 3 - The Path to Institutional Control - Safe, Secure and Stable (R. Liam Mooney, Cameco Corporation (Canada)); 4 - Port Hope Area Initiative: Project Challenges (Scott Parnell, Canadian Nuclear Laboratories (Canada))

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Challenges of Air Monitoring at a Soil Remediation Project in a Suburban Setting - 20448

Air monitoring during soil excavation at a chemically and radiologically impacted site in a suburban setting presents unique challenges. Site activities were conducted in a manner that minimized the release of airborne particulates of concern, principally radionuclides of concern (ROC). Dust and air monitoring were performed to ensure the public was not being exposed to the soil contaminants. The project team collected representative air and dust data while being mindful to not impose on the lives of residents in the area. Due to the close proximity to the public, there was a high level of oversight from the client and regulatory agencies. The challenges involved with air sampling at this soil remediation site located in a suburban setting included the number of contaminants, the ranges of risks and hazards presented by the contaminants and the method of remediation, the concerns of the regulators and the public, and the perception of risk from the public. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

U.S. Department of Energy Consequence Management Under the National Response Framework

Dramatic advances in data management have been made as a result of the Paperless FRMAC initiative, sponsored by the DOE’s Office of Emergency Response (NA-42). The FRMAC (Federal Radiological Monitoring and Assessment Center) is the hub for all radiological monitoring and the production of data products that interpret those measurements in terms of protective action guidelines. As such, very large amounts of data must be quickly assimilated from numerous sources and then widely distributed as graphical interpretations as fast as possible. Paperless FRMAC is a broad initiative to move that data faster, farther and better through telemetry, automation, and networking. This discussion reviews for the first time the status of the now two-year-old Paperless FRMAC initiative. Key features of Paperless FRMAC include multipath telemetry of measurements from DOE field teams, 24/7 Internet presence, early data entry by first responders, support for distance collaborations, and data exchange with the EPA’s SCRIBE database. The heart of the enterprise is the RAMS database, which provides seamless interfacing with GIS, LIMS, and TurboFRMAC for calculations. Paperless FRMAC is presented to users via two Internet websites. The first, FRMAC Portal website, is restricted to the emergency responders for data input, analysis, and product development. The second, CMweb website, is the showroom for completed and approved products, which are made much more widely available. In fact, CMweb offers seamless, single log-in access to all data products for any IMAAC, NARAC or CMweb user.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Measuring Optical Component Radiation Damage

Scintillator based detectors are used to monitor beam losses in the Fermilab accelerator complex. These detectors are approximately 500 times faster than traditional ionization chamber loss monitors and can see beam losses 20 nanoseconds apart. These fast loss monitors are used in areas of the accelerator known to be sources of heavy beam loss and as such, are exposed to high doses of radiation. Over time, radiation exposure reduces the ability of optical components to transmit light by darkening the material. The most dramatic effects are seen in the optical cement and light guide materials comprising the detector. We explore this darkening effect by measuring the transmittance spectra of the detector materials for varying irradiation exposures. Presented here, are the optical transmittance spectra for a variety of radiation exposures and optical materials. The data has revealed an epoxy which withstands exposure far better than traditional optical cements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energetic radiation influence on temperature dependency of Brillouin frequency in optical fibers

We present a post mortem study of the influence of energetic radiation on optical fiber Brillouin sensors, both Brillouin spectrum and its temperature dependency in two different fibers, a photosensitive optical fiber and a SMF28. The target application is nuclear wastes repository monitoring where optical fiber Brillouin sensors might be exposed to energetic radiation. UV exposure induced optical losses, Brillouin frequency shifts up to 28 MHz and even a variation of the temperature dependency. The photosensitive optical fiber resulted more sensitive than SMF28{sup TM}. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Historical Building Stability Monitoring by Means of a Cosmic Ray Tracking System

Cosmic ray radiation is mostly composed, at sea level, by high energy muons, which are highly penetrating particles capable of crossing kilometers of rock. The ubiquitous and steady presence at the Earth's surface and the high penetration capability have motivated the use of cosmic ray radiation also in fields beyond particle physics, from geology, archaeology, speleology to industrial applications and homeland security. In particular, in recent years, the novel technique of muon tomography has been proposed, with the aim of performing non invasive inspection of large non accessible volumes, material atomic number Z and density discrimination, and three dimension image reconstruction of the inspected volume. In the present paper, after a short recall of the physical principles and mathematical formalism on which muon tomography is based, a number of examples of application of the novel technique in industry and homeland security issues is given. Moreover, a new application of cosmic rays detection techniques in the field of civil engineering is proposed. The aim is the monitoring of the stability of large structures, in particular the static monitoring of historical buildings, where conservation constraints are more severe and the time evolution of the deformation phenomena under study may be of the order of months or years. The new technique may be seen, in some way, as the reverse problem of muon tomography. As a significant case study, the monitoring of the wooden vaulted roof of the Palazzo della Loggia in the town of Brescia, in Italy, has been considered. The feasibility as well as the performances and limitations of a monitoring system based on cosmic ray tracking have been studied by Monte Carlo simulation and discussed in comparison with more traditional monitoring systems. (authors)

42 ENGINEERING↗

LDEF contributions to cosmic ray and radiation environments research

LDEF-1 carried three experiments which are producing significant advances in our knowledge of ultra heavy and anomalous cosmic rays, solar flare particles, and heavy nuclei in the trapped belts. Nine other experiments made measurements on the radiation environments or performed dosmetric monitoring. Data from those experiments, and from measurements of induced radioactivity in LDEF components have significantly improved our knowledge of LEO radiation environment. Measurements at various locations shielding depths of radiation absorbed dose, linear energy transfer spectra, proton, neutron and heavy ion fluences, and induced radioactivity have been made, and many of these results have been compared to models. This has allowed the assessment of accuracy, and the potential for improvement, of the models. Serendipitous results from the radiation measurements include the discovery of atmospheric Be-7 plated on the front surface of LDEF, which has motivated a series of new investigations. A sample of measurements and modeling results will be presented, as well as the status of archiving the measurements and models.

Parnell, Thomas A.↗

Optical diffraction radiation from a beam off a circular target

The use of optical diffraction radiation (ODR) as a diagnostic tool has increased in recent years. The potential of this technique has been demonstrated in several experiments at KEK [1], APS [2], FLASH [3] and possibly other facilities. These experiments were performed in extraction beam lines of lepton machines. However this technique can also be applied to high energy hadron beams. In this report we consider the ODR produced by such beams with the target as a round hole and apply the results to the Tevatron. This radiation is produced when a beam passes in the vicinity of a conducting target. The electro-magnetic fields due to the beam induce currents on the target and as the beam propagates, the currents change in time producing radiation both in the direction of beam propagation and along the direction of specular reflection from the target. This latter radiation, also termed backward diffraction radiation (BDR), is more useful for diagnostics since it can be directed out at the same longitudinal location as the target. This radiation is different from optical transition radiation (OTR) in which the beam passes through a metal target. Transition radiation is not suitable for continuous monitoring of a beam in a collider due to the beam energy loss and emittance growth and the fact that the target may be damaged. However the techniques for analyzing ODR are similar in many respects to those for OTR. Measurements of the radiation intensity either in the near field or far-field have been used to determine beam positions and sizes. For example, the beam size and beam position of a 1.28 GeV electron beam were measured in an extraction beam line at KEK [1] using the far-field angular distribution of the radiation. The near-field image was used to monitor the relative beam size of a 7 GeV electron beam in the extraction line at APS [2]. In principle, measurements of the beam divergence are also possible using the interference of ODR between two targets, as has been done with OTR. This paper is motivated by the desire to use this technique in colliders, especially for the LHC and possibly for future colliders envisaged such as the muon collider. A brief report on these prospects was presented earlier [4]. If the technique yields beam measurements with sufficient accuracy and reliability then the non-invasive nature would allow continuous monitoring during the length of a luminosity run. This would be valuable if the beam can be imaged close to the interaction points. Synchrotron radiation is already used as a non-invasive diagnostic tool in the Tevatron and will also be used in the LHC. The principal advantage of ODR is that it can be generated in a straight section and therefore used for imaging in an experimental insertion. The disadvantage is that the ODR flux is less copious than synchrotron radiation (OSR) and imaging will take longer than with OSR. In Section 2 we briefly discuss the parameters of different hadron colliders. In Section 3 we derive the basic results for the angular differential spectrum of ODR from a round hole due to a bunch. We apply these results in Section 4 to find the sensitivity of the spectrum to beam size and offset changes. In Section 5, we calculate the expected photon yield from a bunch per turn as a function of frequency and we use this to find the frequency range where a sufficiently strong ODR signal can be obtained. In Section 6 we do a brief comparison of the ODR spectrum with the OTR spectrum. We briefly list in Section 7 the experimental issues associated with measuring ODR when two beams are present. We end with our conclusions in Section 8. We will use CGS units throughout.

43 PARTICLE ACCELERATORS↗

SNM Radiation Signature Classification Using Different Semi-Supervised Machine Learning Models

The timely detection of special nuclear material (SNM) transfers between nuclear facilities is an important monitoring objective in nuclear nonproliferation. Persistent monitoring enabled by successful detection and characterization of radiological material movements could greatly enhance the nuclear nonproliferation mission in a range of applications. Supervised machine learning can be used to signal detections when material is present if a model is trained on sufficient volumes of labeled measurements. However, the nuclear monitoring data needed to train robust machine learning models can be costly to label since radiation spectra may require strict scrutiny for characterization. Therefore, this work investigates the application of semi-supervised learning to utilize both labeled and unlabeled data. As a demonstration experiment, radiation measurements from sodium iodide (NaI) detectors are provided by the Multi-Informatics for Nuclear Operating Scenarios (MINOS) venture at Oak Ridge National Laboratory (ORNL) as sample data. Anomalous measurements are identified using a method of statistical hypothesis testing. After background estimation, an energy-dependent spectroscopic analysis is used to characterize an anomaly based on its radiation signatures. In the absence of ground-truth information, a labeling heuristic provides data necessary for training and testing machine learning models. Supervised logistic regression serves as a baseline to compare three semi-supervised machine learning models: co-training, label propagation, and a convolutional neural network (CNN). In each case, the semi-supervised models outperform logistic regression, suggesting that unlabeled data can be valuable when training and demonstrating value in semi-supervised nonproliferation implementations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Quantifying the accuracy of the tumor motion and area as a function of acceleration factor for the simulation of the dynamic keyhole magnetic resonance imaging method

Purpose: The dynamic keyhole is a new MR image reconstruction method for thoracic and abdominal MR imaging. To date, this method has not been investigated with cancer patient magnetic resonance imaging (MRI) data. The goal of this study was to assess the dynamic keyhole method for the task of lung tumor localization using cine-MR images reconstructed in the presence of respiratory motion. Methods: The dynamic keyhole method utilizes a previously acquired a library of peripheral k-space datasets at similar displacement and phase (where phase is simply used to determine whether the breathing is inhale to exhale or exhale to inhale) respiratory bins in conjunction with central k-space datasets (keyhole) acquired. External respiratory signals drive the process of sorting, matching, and combining the two k-space streams for each respiratory bin, thereby achieving faster image acquisition without substantial motion artifacts. This study was the first that investigates the impact of k-space undersampling on lung tumor motion and area assessment across clinically available techniques (zero-filling and conventional keyhole). In this study, the dynamic keyhole, conventional keyhole and zero-filling methods were compared to full k-space dataset acquisition by quantifying (1) the keyhole size required for central k-space datasets for constant image quality across sixty four cine-MRI datasets from nine lung cancer patients, (2) the intensity difference between the original and reconstructed images in a constant keyhole size, and (3) the accuracy of tumor motion and area directly measured by tumor autocontouring. Results: For constant image quality, the dynamic keyhole method, conventional keyhole, and zero-filling methods required 22%, 34%, and 49% of the keyhole size (P < 0.0001), respectively, compared to the full k-space image acquisition method. Compared to the conventional keyhole and zero-filling reconstructed images with the keyhole size utilized in the dynamic keyhole method, an average intensity difference of the dynamic keyhole reconstructed images (P < 0.0001) was minimal, and resulted in the accuracy of tumor motion within 99.6% (P < 0.0001) and the accuracy of tumor area within 98.0% (P < 0.0001) for lung tumor monitoring applications. Conclusions: This study demonstrates that the dynamic keyhole method is a promising technique for clinical applications such as image-guided radiation therapy requiring the MR monitoring of thoracic tumors. Based on the results from this study, the dynamic keyhole method could increase the imaging frequency by up to a factor of five compared with full k-space methods for real-time lung tumor MRI.

60 APPLIED LIFE SCIENCES↗

BioSentinel: Mission Development of a Radiation Biosensor to Gauge DNA Damage and Repair Beyond Low Earth Orbit on a 6U Nanosatellite.

We are designing and developing a "6U" (10 x 22 x 34 cm; 14 kg) nanosatellite as a secondary payload to fly aboard NASA's Space Launch System (SLS) Exploration Mission (EM) 1, scheduled for launch in late 2017. For the first time in over forty years, direct experimental data from biological studies beyond low Earth orbit (LEO) will be obtained during BioSentinel's 12- to 18- month mission. BioSentinel will measure the damage and repair of DNA in a biological organism and allow us to compare that to information from onboard physical radiation sensors. In order to understand the relative contributions of the space environment's two dominant biological perturbations, reduced gravity and ionizing radiation, results from deep space will be directly compared to data obtained in LEO (on ISS) and on Earth. These data points will be available for validation of existing biological radiation damage and repair models, and for extrapolation to humans, to assist in mitigating risks during future long-term exploration missions beyond LEO. The BioSentinel Payload occupies 4U of the spacecraft and will utilize the monocellular eukaryotic organism Saccharomyces cerevisiae (yeast) to report DNA double-strand-break (DSB) events that result from ambient space radiation. DSB repair exhibits striking conservation of repair proteins from yeast to humans. Yeast was selected because of 1) its similarity to cells in higher organisms, 2) the well-established history of strains engineered to measure DSB repair, 3) its spaceflight heritage, and 4) the wealth of available ground and flight reference data. The S. cerevisiae flight strain will include engineered genetic defects to prevent growth and division until a radiation-induced DSB activates the yeast's DNA repair mechanisms. The triggered culture growth and metabolic activity directly indicate a DSB and its successful repair. The yeast will be carried in the dry state within the 1-atm P/L container in 18 separate fluidics cards with each card having 16 independent culture microwells, with integral microchannels and filters to supply nutrients and reagents, confine the yeast to the wells, and enable optical measurement. The measurement subsystem will monitor each subgroup of culture wells continuously for several weeks, optically tracking DSBtriggered cell growth and metabolism. BioSentinel will also include physical radiation sensors based on the TimePix sensor, as implemented by JSC's RadWorks group, which record individual radiation events including estimates of their linear-energytransfer (LET) values. Radiation-dose and LET data will be compared directly to the rate of DSB-and-repair events measured by the S. cerevisiae biosentinels. The spacecraft bus will operate in a deep space environment with functions that include command and data handling, communications, power generation (via deployable solar panels) and storage, and attitude determination-and-control system with micropropulsion. Development of the BioSentinel spacecraft will mature and prove multiple nanosatellite advances in order to function well beyond LEO: Communications from distances of ≥ 500,000 km; Autonomous attitude control, momentum management, and safe mode of nanosatellites in deep space; Shielding-, hardening-, design-, and software-derived radiation tolerance for electronics; Reliable functionality for 12 - 18 months of key subsystems for biofluidics, memory, communications, power, etc.; Close integration of living biological radiation event monitors with miniature physical radiation spectrometers; Biological measurement of solar particle events beyond Earth orbit In addition to providing the first biological results from beyond LEO in over 4 decades, BioSentinel will provide an adaptable small-satellite instrument platform to perform a range of human-exploration-relevant measurements that characterize the biological consequences of multiple outer space environments. BioSentinel is being developed under NASA's Advanced Exploration Systems program.

DNA damage↗

First ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The first U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility aerosol chemical speciation monitor (ACSM) users’ meeting was held on April 11-13, 2017, at Aerodyne Research, Inc. in Billerica, Massachusetts, to discuss the Southern Great Plains (SGP) atmospheric observatory ACSM data quality and establish best practices for data collection and processing. The participants examined six years of calibration and processed data. Specific issues raised by data users were addressed and case studies from two field experiments were examined. The most recent data from the ACSM installed in the newly commissioned SGP ARM Mobile Facility 7 (AMF7) were also evaluated. The participants recommended that the SGP ACSM data be reprocessed using calibration values averaged over the history of SGP ACSM calibrations. They also recommended that the data quality be evaluated by comparing (1) observed versus predicted particulate ammonium (NH4+) mass loadings, and (2) ACSM mass loadings versus mass loadings calculated from particle size and light scattering data. The contents of the datastreams from the ACSM were defined based on ARM requirements and the necessary tasks to implement these recommendations were assigned to the mentor and the instrument manufacturer. Some of the recommendations were implemented for the SGP data and are presented in this report. Data from two ARM sites located in marine environments were also analyzed. These analyses as well as instrument intercomparisons have led to further questions about data treatment. These will be addresses in the second users’ meeting scheduled for the summer of 2018.

54 ENVIRONMENTAL SCIENCES↗

First ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The first U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility aerosol chemical speciation monitor (ACSM) users’ meeting was held on April 11-13, 2017, at Aerodyne Research, Inc. in Billerica, Massachusetts, to discuss the Southern Great Plains (SGP) atmospheric observatory ACSM data quality and establish best practices for data collection and processing. The participants examined six years of calibration and processed data. Specific issues raised by data users were addressed and case studies from two field experiments were examined. The most recent data from the ACSM installed in the newly commissioned SGP ARM Mobile Facility 7 (AMF7) were also evaluated. The participants recommended that the SGP ACSM data be reprocessed using calibration values averaged over the history of SGP ACSM calibrations. They also recommended that the data quality be evaluated by comparing (1) observed versus predicted particulate ammonium (NH 4 + ) mass loadings, and (2) ACSM mass loadings versus mass loadings calculated from particle size and light scattering data. The contents of the datastreams from the ACSM were defined based on ARM requirements and the necessary tasks to implement these recommendations were assigned to the mentor and the instrument manufacturer. Some of the recommendations were implemented for the SGP data and are presented in this report. Data from two ARM sites located in marine environments were also analyzed. These analyses as well as instrument intercomparisons have led to further questions about data treatment. These will be addresses in the second users’ meeting scheduled for the summer of 2018.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The first U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility aerosol chemical speciation monitor (ACSM) users’ meeting was held on April 11-13, 2017, at Aerodyne Research, Inc. in Billerica, Massachusetts, to discuss the Southern Great Plains (SGP) atmospheric observatory ACSM data quality and establish best practices for data collection and processing. The participants examined six years of calibration and processed data. Specific issues raised by data users were addressed and case studies from two field experiments were examined. The most recent data from the ACSM installed in the newly commissioned SGP ARM Mobile Facility 7 (AMF7) were also evaluated. The participants recommended that the SGP ACSM data be reprocessed using calibration values averaged over the history of SGP ACSM calibrations. They also recommended that the data quality be evaluated by comparing (1) observed versus predicted particulate ammonium (NH 4 + ) mass loadings, and (2) ACSM mass loadings versus mass loadings calculated from particle size and light scattering data. The contents of the datastreams from the ACSM were defined based on ARM requirements and the necessary tasks to implement these recommendations were assigned to the mentor and the instrument manufacturer. Some of the recommendations were implemented for the SGP data and are presented in this report. Data from two ARM sites located in marine environments were also analyzed. These analyses as well as instrument intercomparisons have led to further questions about data treatment. These will be addresses in the second users’ meeting scheduled for the summer of 2018.

54 ENVIRONMENTAL SCIENCES↗

First ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The first U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility aerosol chemical speciation monitor (ACSM) users’ meeting was held on April 11-13, 2017, at Aerodyne Research, Inc. in Billerica, Massachusetts, to discuss the Southern Great Plains (SGP) atmospheric observatory ACSM data quality and establish best practices for data collection and processing. The participants examined six years of calibration and processed data. Specific issues raised by data users were addressed and case studies from two field experiments were examined. The most recent data from the ACSM installed in the newly commissioned SGP ARM Mobile Facility 7 (AMF7) were also evaluated. The participants recommended that the SGP ACSM data be reprocessed using calibration values averaged over the history of SGP ACSM calibrations. They also recommended that the data quality be evaluated by comparing (1) observed versus predicted particulate ammonium (NH 4 + ) mass loadings, and (2) ACSM mass loadings versus mass loadings calculated from particle size and light scattering data. The contents of the datastreams from the ACSM were defined based on ARM requirements and the necessary tasks to implement these recommendations were assigned to the mentor and the instrument manufacturer. Some of the recommendations were implemented for the SGP data and are presented in this report. Data from two ARM sites located in marine environments were also analyzed. These analyses as well as instrument intercomparisons have led to further questions about data treatment. These will be addresses in the second users’ meeting scheduled for the summer of 2018.

54 ENVIRONMENTAL SCIENCES↗

Comparison of Pyranometers vs. PV Reference Cells for Evaluation of PV Array Performance

As the photovoltaics (PV) industry has grown, the need for accurately monitoring the solar resource of PV power plants has increased. Historically, the PV industry has relied on thermopile pyranometers for irradiance measurements, and a large body of historical irradiance data taken with pyranometers exists. However, interest in PV reference devices is increasing. In this paper, we discuss why PVreference devices are better suited for PV applications, and estimate the typical uncertainties in irradiance measurements made with both pyranometers and PV reference devices. We assert that the quantity of interest in monitoring a PV power plant is the equivalent irradiance under the IEC 60904-3 reference solar spectrum that would produce the same electrical response in the PV array as theincident solar radiation. For PV-plant monitoring applications, we find the uncertainties in irradiance measurements of this type to be on the order of +/-5% for thermopile pyranometers and +/-2.4% for PV reference devices.

14 SOLAR ENERGY↗

Tetris-inspired detector with neural network for radiation mapping

Abstract Radiation mapping has attracted widespread research attention and increased public concerns on environmental monitoring. Regarding materials and their configurations, radiation detectors have been developed to identify the position and strength of the radioactive sources. However, due to the complex mechanisms of radiation-matter interaction and data limitation, high-performance and low-cost radiation mapping is still challenging. Here, we present a radiation mapping framework using Tetris-inspired detector pixels. Applying inter-pixel padding for enhancing contrast between pixels and neural networks trained with Monte Carlo (MC) simulation data, a detector with as few as four pixels can achieve high-resolution directional prediction. A moving detector with Maximum a Posteriori (MAP) further achieved radiation position localization. Field testing with a simple detector has verified the capability of the MAP method for source localization. Our framework offers an avenue for high-quality radiation mapping with simple detector configurations and is anticipated to be deployed for real-world radiation detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Low LET Radiation Spectrometer for Measuring Particle Doses in Space and Aircraft

This paper presents experimental data that demonstrates the feasibility of fabricating a miniature nuclear particle dosimeter for monitoring doses in aircraft and satellites. The basic instrument is a Low Linear-Energy-Transfer (LET) Radiation Spectrometer (LoLRS) that is designed to measure the energy deposited by particles with low LET values. The heart of the instrument is a Silicon-Lithium Drifted Diode (SLDD). Test results show that the LoLRS can be used to monitor the radiation threat to personnel in flights of space- and aircraft and also to generate a comprehensive data base from aviation and satellite measurements that can contribute to the formulation of more accurate environmental radiation models for dose predictions with reduced uncertainty factors.

Stassinopoulos, E. G.↗