Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

SU-E-T-408: Determination of KQ,Q0-Factors From Water and Graphite Calorimetry in a 60 MeV Proton Beam

Purpose: To reduce the uncertainty of the beam quality correction factor k Q,Q0 , for scattered proton beams (SPB). This factor is used in dosimetry protocols, to determine absorbed dose-to-water with ionization chambers. For the Roos plane parallel chambers (RPPICs), the IAEA TRS-398 protocol estimates k Q,Q0 -factor to be 1.004(for a beam quality Rres=2 g.cm{sup 2}), with an uncertainty of 2.1%. Methods: A graphite calorimeter (GCal), a water calorimeter (WCal) and RPPICs were exposed, in a single experiment, to a 60 MeV non-modulated SPB. RPPICs were calibrated in terms of absorbed dose-to-water in a 20 MeV electron beam. The calibration coefficient is traceable to NPL's absorbed dose standards. Chamber measurements were corrected for environmental conditions, recombination and polarity. The WCal corrections include heat loss, heat defect and vessel perturbation. The GCal corrections include heat loss and absorbed dose conversion. Except for heat loss correction and its uncertainty in the WCal system, all major corrections were included in the analysis. Other minor corrections, such as beam profile non-uniformity, are still to be evaluated. Experimental k Q,Q0 -factors were derived by comparing the results obtained with both calorimeters and ionometry. Results: The absorbed dose-to-water from both calorimeters was found to be within 1.3% with an uncertainty of 1.2%. k Q,Q0 -factor for a RPPIC was found to be 0.998 and 1.011, with a standard uncertainty of 1.4% and 0.9% when the dose is based on the GCal and the WCal, respectively. Conclusion: Results suggest the possibility to determine k Q,Q0 -values for PPICs in SPB with a lower uncertainty than specified in the TRS-398 thereby helping to reduce uncertainty on absorbed dose-to-water. The agreement between calorimeters confirms the possibility to use GCal or WCal as primary standard in SPB. Because of the dose conversion, the use of GCal may lead to slightly higher uncertainty, but is, at present, considerably easier to operate.

07 ISOTOPE AND RADIATION SOURCES↗

Measured and Monte Carlo calculated k{sub Q} factors: Accuracy and comparison

Purpose: The journal Medical Physics recently published two papers that determine beam quality conversion factors, k{sub Q}, for large sets of ion chambers. In the first paper [McEwen Med. Phys. 37, 2179-2193 (2010)], k{sub Q} was determined experimentally, while the second paper [Muir and Rogers Med. Phys. 37, 5939-5950 (2010)] provides k{sub Q} factors calculated using Monte Carlo simulations. This work investigates a variety of additional consistency checks to verify the accuracy of the k{sub Q} factors determined in each publication and a comparison of the two data sets. Uncertainty introduced in calculated k{sub Q} factors by possible variation of W/e with beam energy is investigated further. Methods: The validity of the experimental set of k{sub Q} factors relies on the accuracy of the NE2571 reference chamber measurements to which k{sub Q} factors for all other ion chambers are correlated. The stability of NE2571 absorbed dose to water calibration coefficients is determined and comparison to other experimental k{sub Q} factors is analyzed. Reliability of Monte Carlo calculated k{sub Q} factors is assessed through comparison to other publications that provide Monte Carlo calculations of k{sub Q} as well as an analysis of the sleeve effect, the effect of cavity length and self-consistencies between graphite-walled Farmer-chambers. Comparison between the two data sets is given in terms of the percent difference between the k{sub Q} factors presented in both publications. Results: Monitoring of the absorbed dose calibration coefficients for the NE2571 chambers over a period of more than 15 yrs exhibit consistency at a level better than 0.1%. Agreement of the NE2571 k{sub Q} factors with a quadratic fit to all other experimental data from standards labs for the same chamber is observed within 0.3%. Monte Carlo calculated k{sub Q} factors are in good agreement with most other Monte Carlo calculated k{sub Q} factors. Expected results are observed for the sleeve effect and the effect of cavity length on k{sub Q}. The mean percent differences between experimental and Monte Carlo calculated k{sub Q} factors are -0.08, -0.07, and -0.23% for the Elekta 6, 10, and 25 MV nominal beam energies, respectively. An upper limit on the variation of W/e in photon beams from cobalt-60 to 25 MV is determined as 0.4% with 95% confidence. The combined uncertainty on Monte Carlo calculated k{sub Q} factors is reassessed and amounts to between 0.40 and 0.49% depending on the wall material of the chamber. Conclusions: Excellent agreement (mean percent difference of only 0.13% for the entire data set) between experimental and calculated k{sub Q} factors is observed. For some chambers, k{sub Q} is measured for only one chamber of each type--the level of agreement observed in this study would suggest that for those chambers the measured k{sub Q} values are generally representative of the chamber type.

61 RADIATION PROTECTION AND DOSIMETRY↗

Physical Distress, Emotional Status, and Quality of Life in Patients With Nasopharyngeal Cancer Complicated by Post-Radiotherapy Endocrinopathy

Purpose: To explore factors affecting quality of life (QOL) among patients with nasopharyngeal cancer (NPC) complicated by post-radiotherapy endocrinopathy. Methods and Materials: This cross-sectional study was conducted in a tertiary medical center and involved a total of 43 post-radiotherapy, recurrence-free NPC patients with endocrinopathy. They performed self-assessment of their emotional status using the Beck Anxiety Inventory and Beck Depression Inventory-II, and their QoL with the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ-C30) questionnaire and the H and N35 cancer module. Results: Emotional and cognitive functioning of EORTC QLQ-C30 were the most affected. Fatigue, insomnia, and pain were the main concerns. Of the patients, 22 (51.2%) had anxiety and 19 (44.2%) had depression. Both depression and anxiety were negatively correlated with functional scales and global QoL but positively correlated with symptom scales. Multiple linear regression analysis revealed that physical distress symptoms of QLQ-C30 and physical functioning were the significant predictors of global QoL. Emotional and social functioning could predict depression, whereas emotional and physical functioning were significant predictors of anxiety. Conclusions: NPC patients with post-radiotherapy endocrinopathy exhibit impaired cognitive function and negative emotions. Symptoms of physical distress play an important role in QoL perception. Measurement of EORTC QLQ-C30 can be a useful instrument for the early detection of patients' impaired cognitive function and psychological morbidity. The high psychological distress related to the endocrine disturbances or the impact of NPC itself needs further study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correction factors for A1SL ionization chamber dosimetry in TomoTherapy: Machine-specific, plan-class, and clinical fields

Purpose: Recently, an international working group on nonstandard fields presented a new formalism for ionization chamber reference dosimetry of small and nonstandard fields [Alfonso et al., Med. Phys. 35, 5179-5186 (2008)] which has been adopted by AAPM TG-148. This work presents an experimental determination of the correction factors for reference dosimetry with an Exradin A1SL thimble ionization chamber in a TomoTherapy unit, focusing on: (i) machine-specific reference field, (ii) plan-class-specific reference field, and (iii) two clinical treatments. Methods: Ionization chamber measurements were performed in the TomoTherapy unit for intermediate (machine-specific and plan-class-specific) calibration fields, based on the reference conditions defined by AAPM TG-148, and two clinical treatments (lung and head-and-neck). Alanine reference dosimetry was employed to determine absorbed dose to water at the point of interest for the fields under investigation. The corresponding chamber correction factors were calculated from alanine to ionization chamber measurements ratios. Results: Two different methods of determining the beam quality correction factor k{sub Q,Q{sub 0}} for the A1SL ionization chamber in this TomoTherapy unit, where reference conditions for conventional beam quality determination cannot be met, result in consistent values. The observed values of overall correction factors obtained for intermediate and clinical fields are consistently around 0.98 with a typical expanded relative uncertainty of 2% (k = 2), which when considered make such correction factors compatible with unity. However, all of them are systematically lower than unity, which is shown to be significant when a hypothesis test assuming a t-student distribution is performed (p=1.8x10{sup -2}). Correction factors k{sub Q{sub c{sub l{sub i{sub n,Q{sub p{sub c{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub p}{sub c}{sub s}{sub r}}}}}}}}}} and k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, which are needed for the computation of field factors for relative dosimetry of clinical beams, have been found to be very close to unity for two clinical treatments. Conclusions: The results indicate that the helical field deliveries in this study (including two clinical fields) do not introduce changes on the ion chamber correction factors for dosimetry. For those two specific clinical cases, ratios of chamber readings accurately represent field output factors. The values observed here for intermediate calibration fields are in agreement with previously published data based on alanine dosimetry but differ from values recently reported obtained via radiochromic dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Injection Locking of Gigahertz‐Frequency Surface Acoustic Wave Phononic Crystal Oscillator

Low-noise gigahertz (GHz) frequency sources are essential for applications in signal processing, sensing, and telecommunications. Surface acoustic wave (SAW) resonator-based oscillators offer compact form factors and low-phase noise due to their short mechanical wavelengths and high-quality (Q) factors. However, their small footprint makes them vulnerable to environmental variation, resulting in their poor long-term frequency stability. Injection locking is widely used to suppress frequency drift of lasers and oscillators by synchronizing to an ultra-stable reference. Here, injection locking of a 1-GHz SAW phononic-crystal oscillator is demonstrated, achieving 40-dB phase noise reduction at low offset frequencies and unperturbed low noise at large offset frequencies. Compared to a free-running SAW oscillator, which typically exhibits frequency drifts of several hundred hertz over minutes, the injection-locked oscillator reduces the frequency deviation to below 0.35 Hz. The locking range and oscillator dynamics is also investigated in the injection pulling region. The demonstrated injection-locked SAW oscillator could find applications in high-performance portable telecommunications and sensing systems.

injection locking↗

Predictors of Dysgeusia in Patients With Oropharyngeal Cancer Treated With Chemotherapy and Intensity Modulated Radiation Therapy

Objective(s): Dysgeusia is a significant factor reducing quality of life and worsening dysphagia in patients receiving chemoradiation therapy for head and neck cancer. The factors affecting dysgeusia severity are uncertain. We investigated the effects on patient-reported dysgeusia of doses to the oral cavity, salivary output (required to dissolve food particles), and patient-reported xerostomia. Methods and Materials: Seventy-three patients with stage III to IV oropharyngeal cancer (OPC) (N=73) receiving definitive intensity modulated radiation therapy concurrently with chemotherapy participated in a prospective, longitudinal study of quality of life (QOL), including assessment of patient-reported gustatory function by taste-related questions from the Head and Neck QOL instrument (HNQOL) and the University of Washington Head and Neck-related QOL instrument (UWQOL), before therapy and periodically after treatment. At these intervals, patients also completed a validated xerostomia-specific questionnaire (XQ) and underwent unstimulated and stimulated major salivary gland flow rate measurements. Results: At 1, 3, 6, and 12 months after treatment, dysgeusia improved over time: severe dysgeusia was reported by 50%, 40%, 22%, and 23% of patients, respectively. Significant associations were found between patient-reported severe dysgeusia and radiation dose to the oral cavity (P=.005) and tongue (P=.019); normal tissue complication probability for severe dysgeusia at 3 months showed mean oral cavity D{sub 50} doses 53 Gy and 57 Gy in the HNQOL and WUQOL questionnaires, respectively, with curve slope (m) of 0.41. Measured salivary output was not statistically significantly correlated with severe taste dysfunction, whereas patient-reported XQ summary scores and xerostomia while eating scores were correlated with severe dysgeusia in the UWQOL tool (P=.04). Conclusions: Taste impairment is significantly correlated with mean radiation dose to the oral cavity. Patient-reported xerostomia, but not salivary output, was correlated with severe dysgeusia in 1 of the 2 QOL questionnaires. Reduction in oral cavity doses is likely to improve dysgeusia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Finding Uncertainties that Cause the Age Dependence of Dose Limits to Be Immature

Space radiation permissible exposure limits (PEL) are intended to set acceptable levels of cancer risks, and avoid any clinical significant non-cancer effects. The 1989 recommendation of the National Council of Radiation Protection and Measurements (NCRP) recommended a strong age dependence of dose limits that departed drastically from the then mature 1970 dose limits recommendations from the National Academy of Science, which were independent of age. In 2000, the NCRP recommended revised limits that showed a similar trend of risk with age to the 1989 report. In this model, the cancer risk per Sv varies by more than 2-fold for ages between 30- and 50-yr. Therefore for galactic cosmic rays exposure, astronaut age has a larger influence on risk then radiation shielding mass or material composition, vehicle propulsion method, or position in the solar cycle. For considering the control of mission costs and resources, the possibility of using astronaut age as a trade variable in mission design could be considered. However, the uncertainties in describing the age dependence on risk have not been fully explored. We discuss biological factors that influence the age dependence of radiation risks, including susceptibility, expression and latency, and radiation quality. These factors depend not only on the individual s age, but also their genetic sensitivity and interaction with other environmental factors. Epidemiological data is limited in describing the age dependence on risk. The 2005, BEIR VII report recommends an age dependence for cancer risk attributable solely to the life-table disagreeing strongly with the NCRP model. However, BEIR VII also noted the limited power of human data for concomitantly describing both age and age after exposure dependences of cancer risks. Many experimental studies have shown that high LET radiation (e.g., high charge and energy (HZE) nuclei and neutrons) display reduced latency compared to low LET radiation, suggesting distinct biological factors are important. We discuss potential molecular mechanisms that would influence the age dependence of radiation risks. A probability distribution function for the uncertainties in age-dependence of risk models is described and predictions for Mars missions discussed. Our report suggests that theoretical considerations based on new experimental studies are needed to ensure the correct age dependence in space radiation risk models and the resulting Astronaut PEL.

Cucinotta, Francis A.↗

Watershed-Scale Modeling of Land-Use and Altered Environment Impacts on Aquatic Weed Growth in the Delta

The California Sacramento-San Joaquin River Delta is the hub for California's water supply, conveying water from Northern to Southern California agriculture and communities while supporting important ecosystem services, agriculture, and communities in the Delta. Changes in climate, long-term drought, and water quality have all been suspected as playing role in the dramatic expansion of invasive aquatic plants and their impact on ecosystems of the San Francisco Bay / California Delta complex. NASA Ames Research Center, USDA-Agricultural Research Service, the State of California, UC Davis, and local governments have partnered under a USDA sponsored project (DRAAWP) to develop science-based, adaptive-management strategies for invasive aquatic plants in Sacramento-San Joaquin Delta. Critical to developing management strategies is to understand how the Delta is affected by both the magnitude of fluctuations in land-use and climate / drought induced altered environments and how the plants respond to these altered environments. We utilize the Soil Water Assessment Tool (SWAT), a watershed-scale model developed to quantify the impact of land management practices in large and complex watersheds on water quality, as the backbone for a customized Delta model - Delta-SWAT. The model uses land-use, soils, elevation, and hydrologic routing to characterize pesticide and nutrient transport from the Sacramento and San Joaquin rivers watersheds and loading into the Delta. Land-use within the Delta, as well as water extraction to supply those functions, and the resulting return of water to Delta waterways are included in Delta-SWAT. Hydrologic transport within the Delta has required significant attention to address the lack of elevation driven transport processes. Delta-SWAT water quality trend estimates are compared with water quality monitoring conducted throughout the Delta. Aquatic plant response to water quality and other environmental factors is carried out using a customized model component. Plant response to the range of water quality factors, response times, and altered temperature and light regimes of the Delta have required gap-filling studies to provide model parameters. Delta-SWAT provides a tool for evaluating temporal and spatial effects of land-use and altered environments in the Delta and contributing watersheds on aquatic weed growth. Using Delta-SWAT for simulation modeling allows evaluation of historic and current conditions as well as consideration potential climate change and management practice outcomes. Delta-SWAT adds to the scientific understanding of dynamics in the Delta and enhances development of science-informed, management strategies and practices.

Ecosystem↗

Factors affecting the exposure of passengers, service staff and train drivers inside trains to airborne particles

Highlights: • The effect of tunnel environment on train air quality differs for different train cabins. • Interior ventilation has a significant effect on the particles inside the train. • The closed train door in the driver cabin acts as a filter for coarse particles. • Commuters experience the highest particle exposure, but service staff receive the highest daily deposition dose. This study investigated train air conditioning filters, interior ventilation systems, tunnel environments and platform air quality as factors affecting the concentrations of airborne particles inside trains and provides information on the exposure of passengers, train drivers and service staff to particles. Particle sampling was done inside the passenger cabin, the driver cabin and the service staff cabin during on-board measurement campaigns in 2016 and 2017. The results show that interior ventilation plays a key role in maintaining cleaner in-train air. Noticeable increases in PM{sub 10} and PM{sub 2.5} levels were observed for all of the measured cabins when the train was running in the newly opened tunnel. The increases occurred when the doors of the passenger cabin and the service staff cabin were open at underground stations. The door to the driver cabin, which remained closed for the entire measurement period, acted as a filter for coarse particles (PM{sub 2.5–10}). The highest particle exposure occurred in the passenger cabin, followed by the service staff cabin, while the driver had the lowest exposure. The highest deposition dose occurs for the service staff and the lowest for commuters.

54 ENVIRONMENTAL SCIENCES↗

Influence of moisture content, particle size and forming temperature on productivity and quality of rice straw pellets

Highlights: • Optimized conditions were determined for the production of rice straw pellets. • The moisture content and forming temperature are key factors. • High quality rice pellets in the lower heating value and durability were produced. - Abstract: A large amount of rice straw is generated and left as much in paddy fields, which causes greenhouse gas emissions as methane. Rice straw can be used as bioenergy. Rice straw pellets are a promising technology because pelletization of rice straw is a form of mass and energy densification, which leads to a product that is easy to handle, transport, store and utilize because of the increase in the bulk density. The operational conditions required to produce high quality rice straw pellets have not been determined. This study determined the optimal moisture content range required to produce rice straw pellets with high yield ratio and high heating value, and also determined the influence of particle size and the forming temperature on the yield ratio and durability of rice straw pellets. The optimal moisture content range was between 13% and 20% under a forming temperature of 60 or 80 °C. The optimal particle size was between 10 and 20 mm, considering the time and energy required for shredding, although the particle size did not significantly affect the yield ratio and durability of the pellets. The optimized conditions provided high quality rice straw pellets with nearly 90% yield ratio, ⩾12 MJ/kg for the lower heating value, and >95% durability.

09 BIOMASS FUELS↗

Peanut allergy burden survey: Factors associated with health‐related quality of life in adolescents

Abstract Background Patients with peanut allergy (PA) experience significant burden of illness, which impacts health‐related quality of life (HRQoL), particularly in adolescence. There is a paucity of research evaluating drivers of HRQoL scores. Methods A prospective, online survey of adolescents with self‐reported, provider‐diagnosed PA completed from November 2018 to January 2019 was used to explore drivers of the real‐world impact of PA on HRQoL using the Pediatric Quality of Life Inventory 4.0 (PedsQL) and other measures. Univariate and multivariate analyses were used to identify potential factors associated with PedsQL scores and to understand the level of association. Results A total of 102 adolescents were included. The final model included 10 variables: race, reported strict peanut avoidance, satisfaction with prophylaxis, moderate‐to‐severe reaction within the past 12 months, touching peanut as cause of most severe reaction, fear of reaction, age, gender, comorbidities, and daily life limitations. In total, three items were shown to be strong predictors of the PedsQL total score including cause of severe reaction was touching peanut (yes), level of agreement with avoiding peanut (completely agree), and satisfaction with prophylaxis (not very much/not at all). Conclusions There is substantial heterogeneity in the impact of the burden of PA on PedsQL scores across patients. This indicates the importance of shared and individualized decision making for PA management to optimize outcomes and improve HRQoL.

McCann, William A.↗

TH-E-BRE-06: Challenges in the Dosimetry of Flattening Filter Free Beams

Purpose: In current dosimetry protocols [AAPM TG51, IAEA TRS-389] the beam quality correction factor kQ and the water-to-air restricted mass collision stopping-power ratio SPR are related to beam quality specifiers %dd(10){sub x} respectively TPR{sub 20,10} Determining kQ and SPR using these regular beam quality specifiers for conventional accelerators (WFF) and flattening filter free accelerators (FFF) similarly could lead to systemic bias.The influence of the flattening filter on the relationship between various beam quality specifiers and SPR respectively k{sub Q} was studied using Monte Carlo simulations with realistic beam sources. Methods: All Monte Carlo simulations were performed using the BEAMnrc/EGSnrc code system. Radiation transport through nine linear accelerator heads modeled according to technical drawings given by the manufactures and a {sup 60} Co therapy source was simulated with BEAMnrc and then used as a radiation source for further simulations. FFF beam sources were implemented by removing the fattening filter from the WFF model. SPR was calculated applying the user code SPRRZnrc. The mean photon energy below the accelerator head and the mean energies of photons and electrons at the measuring point within the water phantom were calculated using FLURZnrc. Dose calculations within a small water voxel and the thimble ionization chamber PTW-31010 in a water depth of 10 cm were made using the egs-chamber code. Results: SPR and k{sub Q} as a function of fluence spectra based beam quality specifiers as well as conventional beam quality specifiers differ systematically between FFF and WFF beams. According to the results the specifier %dd(10){sub x} revealed the smallest deviation (max. 0.4%) between FFF and WFF beams. Conclusion: The results show that %dd(10){sub x} is an acceptable beam quality specifier for FFF beams. Nevertheless the results confirm the expected bias between FFF and WFF beams which must by further investigated.

07 ISOTOPE AND RADIATION SOURCES↗

Experimental investigation of factors limiting slow axis beam quality in 9xx nm high power broad area diode lasers

GaAs-based broad-area diode lasers are needed with improved lateral beam parameter product (BPP{sub lat}) at high power. An experimental study of the factors limiting BPP{sub lat} is therefore presented, using extreme double-asymmetric (EDAS) vertical structures emitting at 910 nm. Continuous wave, pulsed and polarization-resolved measurements are presented and compared to thermal simulation. The importance of thermal and packaging-induced effects is determined by comparing junction -up and -down devices. Process factors are clarified by comparing diodes with and without index-guiding trenches. We show that in all cases studied, BPP{sub lat} is limited by a non-thermal BPP ground-level and a thermal BPP, which depends linearly on self-heating. Measurements as a function of pulse width confirm that self-heating rather than bias-level dominates. Diodes without trenches show low BPP ground-level, and a thermal BPP which depends strongly on mounting, due to changes in the temperature profile. The additional lateral guiding in diodes with trenches strongly increases the BPP ground-level, but optically isolates the stripe from the device edges, suppressing the influence of the thermal profile, leading to a BPP-slope that is low and independent of mounting. Trenches are also shown to initiate strain fields that cause parasitic TM-polarized emission with large BPP{sub lat}, whose influence on total BPP{sub lat} remains small, provided the overall polarization purity is >95%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV)

Purpose: High energy photon beams are used in calibrating dosimeters for use in brachytherapy since absorbed dose to water can be determined accurately and with traceability to primary standards in such beams, using calibrated ion chambers and standard dosimetry protocols. For use in brachytherapy, beam quality correction factors are needed, which include corrections for differences in mass energy absorption properties between water and detector as well as variations in detector response (intrinsic efficiency) with radiation quality, caused by variations in the density of ionization (linear energy transfer (LET) -distributions) along the secondary electron tracks. The aim of this work was to investigate experimentally the detector response of LiF:Mg,Ti thermoluminescent dosimeters (TLD) for photon energies below 1 MeV relative to {sup 60}Co and to address discrepancies between the results found in recent publications of detector response. Methods: LiF:Mg,Ti dosimeters of formulation MTS-N Poland were irradiated to known values of air kerma free-in-air in x-ray beams at tube voltages 25-250 kV, in {sup 137}Cs- and {sup 60}Co-beams at the Swedish Secondary Standards Dosimetry Laboratory. Conversions from air kerma free-in-air into values of mean absorbed dose in the dosimeters in the actual irradiation geometries were made using EGSnrc Monte Carlo simulations. X-ray energy spectra were measured or calculated for the actual beams. Detector response relative to that for {sup 60}Co was determined at each beam quality. Results: An increase in relative response was seen for all beam qualities ranging from 8% at tube voltage 25 kV (effective energy 13 keV) to 3%-4% at 250 kV (122 keV effective energy) and {sup 137}Cs with a minimum at 80 keV effective energy (tube voltage 180 kV). The variation with effective energy was similar to that reported by Davis et al.[Radiat. Prot. Dosim. 106, 33-43 (2003)] with our values being systematically lower by 2%-4%. Compared to the results by Nunn et al.[Med. Phys. 35, 1861-1869 (2008)], the relative detector response as a function of effective energy differed in both shape and magnitude. This could be explained by the higher maximum read-out temperature (350 deg. C) used by Nunn et al.[Med. Phys. 35, 1861-1869 (2008)], allowing light emitted from high-temperature peaks with a strong LET dependence to be registered. Use of TLD-100 by Davis et al.[Radiat. Prot. Dosim. 106, 33-43 (2003)] with a stronger super-linear dose response compared to MTS-N was identified as causing the lower relative detector response in this work. Conclusions: Both careful dosimetry and strict protocols for handling the TLDs are required to reach solid experimental data on relative detector response. This work confirms older findings that an over-response relative to {sup 60}Co exists for photon energies below 200-300 keV. Comparison with the results from the literature indicates that using similar protocols for annealing and read-out, dosimeters of different makes (TLD-100, MTS-N) differ in relative detector response. Though universality of the results has not been proven and further investigation is needed, it is anticipated that with the use of strict protocols for annealing and read-out, it will be possible to determine correction factors that can be used to reduce uncertainties in dose measurements around brachytherapy sources at photon energies where primary standards for absorbed dose to water are not available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Needs of the transportation community: Present and near future

The impact on the passenger of all aspects of the carrier vehicle physical environment that affect his acceptance of the ride was studied. While motion and vibration are recognized as prime factors affecting subjective reactions, ride quality includes other factors as well (e.g., noise, roominess, etc.) which also can be important. Variables (both subjective and objective) involved and of the interacting effects between variables are identified.

Source record↗

Food Quality and Phytoplankton Community Composition in San Francisco Bay using Imaging Spectroscopy Data from the California HyspIRI Airborne Campaign

The San Francisco Bay (SFB) is the largest estuary on the west coast of the United States. It is an important transition zone between marine, freshwater, and inland terrestrial watersheds. The SFB is an important region for the cycling of nutrients and pollutants and it supports nurseries of ecologically and commercially important fisheries, including some threatened species. Phytoplankton community structure influences food web dynamics, and the taxonomy of the phytoplankton may be more important in determining primary food quality than environmental factors. As such, estimating food quality from phytoplankton community composition can be a robust tool to understand trophic transfer of energy. Recent work explores phytoplankton food quality in SFB through the use of microscopy and phytoplankton chemotaxonomy to evaluate how changes in phytoplankton composition may have influenced the recent trophic collapse of pelagic fishes in the northern part of the SFB. The objective of this study is to determine if the approach can also be applied to imaging spectroscopy data in order to quantify phytoplankton food quality from space. Imaging spectroscopy data of SFB from the Airborne VisibleInfrared Imaging Spectrometer (AVIRIS) was collected during the Hyperspectral Infrared (HyspIRI) Airborne Campaign in California (2013 2015) and used in this study. Estimates of ocean chlorophyll and phytoplankton community structure were determined using standard ocean chlorophyll algorithms and the PHYtoplankton Detection with Optics (PHYDOTax) algorithms. These were validated using in situ observations of phytoplankton composition using microscopic cell counts and phytoplankton chemotaxonomy from the US Geological Surveys ship surveys of the SFB. The findings from this study may inform the use of future high spectral resolution satellite sensors with the spatial resolution appropriate for coastal systems (e.g., HyspIRI) to assess food quality from space.

HyspIRI↗

Effective bichromatic potential for ultra-high Q-factor photonic crystal slab cavities

We introduce a confinement mechanism in photonic crystal slab cavities, which relies on the superposition of two incommensurate one-dimensional lattices in a line-defect waveguide. It is shown that the resulting photonic profile realizes an effective quasi-periodic bichromatic potential for the electromagnetic field confinement yielding extremely high quality (Q) factor nanocavities, while simultaneously keeping the mode volume close to the diffraction limit. We apply these concepts to pillar- and hole-based photonic crystal slab cavities, respectively, and a Q-factor improvement by over an order of magnitude is shown over existing designs, especially in pillar-based structures. Thanks to the generality and easy adaptation of such confinement mechanism to a broad class of cavity designs and photonic lattices, this work opens interesting routes for applications where enhanced light–matter interaction in photonic crystal structures is required.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗