Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pressurization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

On the structure of pressure fluctuations in simulated turbulent channel flow

Pressure fluctuations in a turbulent channel flow are investigated by analyzing a database obtained from a direct numerical simulation. Detailed statistics associated with the pressure fluctuations are presented. Characteristics associated with the rapid (linear) and slow (nonlinear) pressure are discussed. It is found that the slow pressure fluctuations are larger than the rapid pressure fluctuations throughout the channel except very near the wall, where they are about the same magnitude. This is contrary to the common belief that the nonlinear source terms are negligible compared to the linear source terms. Probability density distributions, power spectra, and two-point correlations are examined to reveal the characteristics of the pressure fluctuations. The global dependence of the pressure fluctuations and pressure-strain correlations are also examined by evaluating the integral associated with Green's function representations of them. In the wall region where the pressure-strain terms are large, most contributions to the pressure-strain terms are from the wall region (i.e., local), whereas away from the wall where the pressure-strain terms are small, contributions are global. Structures of instantaneous pressure and pressure gradients at the wall and the corresponding vorticity field are examined.

Kim, John↗

On the structure of pressure fluctuations in simulated turbulent channel flow

Pressure fluctuations in a turbulent channel flow are investigated by analyzing a database obtained from a direct numerical simulation. Detailed statistics associated with the pressure fluctuations are presented. Characteristics associated with the rapid (linear) and slow (nonlinear) pressure are discussed. It is found that the slow pressure fluctuations are larger than the rapid pressure fluctuations throughout the channel except very near the wall, where they are about the same magnitude. This is contrary to the common belief that the nonlinear source terms are negligible compared to the linear source terms. Probability density distributions, power spectra, and two-point correlations are examined to reveal the characteristics of the pressure fluctuations. The global dependence of the pressure fluctuations and pressure-strain correlations are also examined by evaluating the integral associated with Green's function representations of them. In the wall region where the pressure-strain terms are large, most contributions to the pressure-strain terms are from the wall region (i.e., local), whereas away from the wall where the pressure-strain terms are small, contributions are global. Structures of instantaneous pressure and pressure gradients at the wall and the corresponding vorticity field are examined.

Kim, John↗

Laser Scanning System for Pressure and Temperature Paints

Acquiring pressure maps of aerodynamic surfaces is very important for improving and validating the performance of aerospace vehicles. Traditional pressure measurements are taken with pressure taps embedded in the model surface that are connected to transducers. While pressure taps allow highly accurate measurements to be acquired, they do have several drawbacks. Pressure taps do not give good spatial resolution due to the need for individual pressure tubes, compounded by limited space available inside models. Also, building a model proves very costly if taps are needed because of the large amount of labor necessary to drill, connect and test each one. The typical cost to install one tap is about $200. Recently, a new method for measuring pressure on aerodynamic surfaces has been developed utilizing a technology known as pressure sensitive paints (PSP). Using PSP, pressure distributions can be acquired optically with high spatial resolution and simple model preparation. Flow structures can be easily visualized using PSP, but are missed using low spatial resolution arrays of pressure taps. PSP even allows pressure distributions to be found on rotating machinery where previously this has been extremely difficult or even impossible. The goal of this research is to develop a laser scanning system for use with pressure sensitive paints that allows accurate pressure measurements to be obtained on various aerodynamic surfaces ranging from wind tunnel models to high speed jet engine compressor blades.

Sullivan, John↗

Laser Scanning System for Pressure and Temperature Paints

Acquiring pressure maps of aerodynamic surfaces is very important for improving and validating the performance of aerospace vehicles. Traditional pressure measurements are taken with pressure taps embedded in the model surface that are connected to transducers. While pressure taps allow highly accurate measurements to be acquired, they do have several drawbacks. Pressure taps do not give good spatial resolution due to the need for individual pressure tubes, compounded by limited space available inside models. Also, building a model proves very costly if taps are needed because of the large amount of labor necessary to drill, connect and test each one. The typical cost to install one tap is about $200. Recently, a new method for measuring pressure on aerodynamic surfaces has been developed utilizing a technology known as pressure sensitive paints (PSP). Using PSP, pressure distributions can be acquired optically with high spatial resolution and simple model preparation. Flow structures can be easily visualized using PSP, but are missed using low spatial resolution arrays of pressure taps. PSP even allows pressure distributions to be found on rotating machinery where previously this has been extremely difficult or even impossible. The goal of this research is to develop a laser scanning system for use with pressure sensitive paints that allows accurate pressure measurements to be obtained on various aerodynamic surfaces ranging from wind tunnel models to high speed jet engine compressor blades.

Sullivan, John↗

Neural Network Prediction of Failure of Damaged Composite Pressure Vessels from Strain Field Data Acquired by a Computer Vision Method

This effort used a new and novel method of acquiring strains called Sub-pixel Digital Video Image Correlation (SDVIC) on impact damaged Kevlar/epoxy filament wound pressure vessels during a proof test. To predict the burst pressure, the hoop strain field distribution around the impact location from three vessels was used to train a neural network. The network was then tested on additional pressure vessels. Several variations on the network were tried. The best results were obtained using a single hidden layer. SDVIC is a fill-field non-contact computer vision technique which provides in-plane deformation and strain data over a load differential. This method was used to determine hoop and axial displacements, hoop and axial linear strains, the in-plane shear strains and rotations in the regions surrounding impact sites in filament wound pressure vessels (FWPV) during proof loading by internal pressurization. The relationship between these deformation measurement values and the remaining life of the pressure vessels, however, requires a complex theoretical model or numerical simulation. Both of these techniques are time consuming and complicated. Previous results using neural network methods had been successful in predicting the burst pressure for graphite/epoxy pressure vessels based upon acoustic emission (AE) measurements in similar tests. The neural network associates the character of the AE amplitude distribution, which depends upon the extent of impact damage, with the burst pressure. Similarly, higher amounts of impact damage are theorized to cause a higher amount of strain concentration in the damage effected zone at a given pressure and result in lower burst pressures. This relationship suggests that a neural network might be able to find an empirical relationship between the SDVIC strain field data and the burst pressure, analogous to the AE method, with greater speed and simplicity than theoretical or finite element modeling. The process of testing SDVIC neural network analysis and some encouraging preliminary results are presented in this paper. Details are given concerning the processing of SDVIC output data such that it may be used as back propagation neural network (BPNN) input data. The software written to perform this processing and the BPNN algorithm are also discussed. It will be shown that, with limited training, test results indicate an average error in burst pressure prediction of approximately six percent,

Russell, Samuel S.↗

Dynamic Pressure Probes Developed for Supersonic Flow-Field Measurements

A series of dynamic flow-field pressure probes were developed for use in large-scale supersonic wind tunnels at the NASA Glenn Research Center. These flow-field probes include pitot and static pressure probes that can capture fast-acting flow-field pressure transients occurring on a millisecond timescale. The pitot and static probes can be used to determine local Mach number time histories during a transient event. The flow-field pressure probe contains four major components: 1) Static pressure aerodynamic tip; 2) Pressure-sensing cartridge assembly; 3) Pitot pressure aerodynamic tip; 4) Mounting stem. This modular design allows for a variety of probe tips to be used for a specific application. Here, the focus is on flow-field pressure measurements in supersonic flows, so we developed a cone-cylinder static pressure tip and a pitot pressure tip. Alternatively, probe tips optimized for subsonic and transonic flows could be used with this design. The pressure-sensing cartridge assembly allows the simultaneous measurement of steady-state and transient pressure which allows continuous calibration of the dynamic pressure transducer.

Porro, A. Robert↗

Prevention of Over-Pressurization During Combustion in a Sealed Chamber

The combustion of flammable material in a sealed chamber invariably leads to an initial pressure rise in the volume. The pressure rise is due to the increase in the total number of gaseous moles (condensed fuel plus chamber oxygen combining to form gaseous carbon dioxide and water vapor) and, most importantly, the temperature rise of the gas in the chamber. Though the rise in temperature and pressure would reduce with time after flame extinguishment due to the absorption of heat by the walls and contents of the sealed spacecraft, the initial pressure rise from a fire, if large enough, could lead to a vehicle over-pressure and the release of gas through the pressure relief valve. This paper presents a simple lumped-parameter model of the pressure rise in a sealed chamber resulting from the heat release during combustion. The transient model considers the increase in gaseous moles due to combustion, and heat transfer to the chamber walls by convection and radiation and to the fuel-sample holder by conduction, as a function of the burning rate of the material. The results of the model are compared to the pressure rise in an experimental chamber during flame spread tests as well as to the pressure falloff after flame extinguishment. The experiments involve flame spread over thin solid fuel samples. Estimates of the heat release rate profiles for input to the model come from the assumed stoichiometric burning of the fuel along with the observed flame spread behavior. The sensitivity of the model to predict maximum chamber pressure is determined with respect to the uncertainties in input parameters. Model predictions are also presented for the pressure profile anticipated in the Fire Safety-1 experiment, a material flammability and fire safety experiment proposed for the European Space Agency (ESA) Automated Transfer Vehicle (ATV). Computations are done for a range of scenarios including various initial pressures and sample sizes. Based on these results, various mitigation approaches are suggested to prevent vehicle over-pressurization and help guide the definition of the space experiment.

Gokoglu, Suleyman A.↗

Pressure-Sensitive Paints Advance Rotorcraft Design Testing

The rotors of certain helicopters can spin at speeds as high as 500 revolutions per minute. As the blades slice through the air, they flex, moving into the wind and back out, experiencing pressure changes on the order of thousands of times a second and even higher. All of this makes acquiring a true understanding of rotorcraft aerodynamics a difficult task. A traditional means of acquiring aerodynamic data is to conduct wind tunnel tests using a vehicle model outfitted with pressure taps and other sensors. These sensors add significant costs to wind tunnel testing while only providing measurements at discrete locations on the model's surface. In addition, standard sensor solutions do not work for pulling data from a rotor in motion. "Typical static pressure instrumentation can't handle that," explains Neal Watkins, electronics engineer in Langley Research Center s Advanced Sensing and Optical Measurement Branch. "There are dynamic pressure taps, but your costs go up by a factor of five to ten if you use those. In addition, recovery of the pressure tap readings is accomplished through slip rings, which allow only a limited amount of sensors and can require significant maintenance throughout a typical rotor test." One alternative to sensor-based wind tunnel testing is pressure sensitive paint (PSP). A coating of a specialized paint containing luminescent material is applied to the model. When exposed to an LED or laser light source, the material glows. The glowing material tends to be reactive to oxygen, explains Watkins, which causes the glow to diminish. The more oxygen that is present (or the more air present, since oxygen exists in a fixed proportion in air), the less the painted surface glows. Imaged with a camera, the areas experiencing greater air pressure show up darker than areas of less pressure. "The paint allows for a global pressure map as opposed to specific points," says Watkins. With PSP, each pixel recorded by the camera becomes an optical pressure tap. "Instead of having 100 or 200 pressure taps, you can have in theory several million, up to whatever the resolution of your camera is." Watkins explains that typical wind tunnel testing requires two models: one with very little instrumentation, and a pressure model with a significant amount of sensors applied. "If you can make all of your measurements on one model with PSP, you've decreased your model costs by at least a factor of two and preferably your testing costs by about that much," he says. PSP technology has been around for almost 20 years, but a PSP solution for gathering instantaneous dynamic pressure data from surfaces moving at high speeds, such as rotor blades, was not available until a NASA partnership led to a game-changing innovation.

Source record↗

Are Medications Involved in Vision and Intracrancial Pressure Changes Seen in Spaceflight?

The Food and Drug Association Adverse Event Reports (FDA AER) from 2009-2011 were used to create a database from millions of known and suspected medication-related adverse events among the general public. Vision changes, sometimes associated with intracranial pressure changes (VIIP), have been noted in some long duration crewmembers. Changes in vision and blood pressure (which can subsequently affect intracranial pressure) are fairly common side effects of medications. The purpose of this study was to explore the possibility of medication involvement in crew VIIP symptoms. Reports of suspected medication-related adverse events may be filed with the Food and Drug Administration (FDA) by medical professionals or consumers. Quarterly compilations of these reports are available for public download. Adverse Event Reporting System (AERS) reports from 1/1/2009- 6/30/2012 were downloaded and compiled into a searchable database for this study. Reports involving individuals under the age of 18 and older than 65 were excluded from this analysis. Case reports involving chronic diseases such as cancer, diabetes, multiple sclerosis and other serious conditions were also excluded. A scan of the medical literature for medication-related VIIP-like adverse events was used to create a list of suspect medications. These medications, as well as certain medications used frequently by ISS crew, were used to query the database. Queries for use of suspected medications were run, and the nature of the symptoms reported in those cases were tabulated. Symptoms searched in the FDA AERS were chosen to include the typical symptoms noted in crewmembers with VIIP. Vision symptoms searched were: visual acuity reduced, visual impairment, and vitreous floaters. Pressure changes included: abnormal sensation in eye, intracranial pressure increased, intraocular pressure increased, optic neuritis, optic neuropathy, and papilloedema. Limited demographic information is included with the FDA AERS; relevant data were also sorted by age and sex from each report. RESULTS Steroid-containing oral contraceptives had the highest number of reports associated with vision (n=166) and pressure symptoms (n=54). Corticosteroid-containing medications were also high; prednisone, for example, had 137 reports of vision issues and 79 of pressure issues. Pain relievers were also a medication class with vision and pressure-related adverse events reported. Common over-the-counter medications such as acetaminophen, aspirin and ibuprofen each had multiple reports for both vision and pressure symptoms. Antimicrobial medications ciprofloxacin and diflucan were also associated with a number of vision and pressure-related AERS. Unexpectedly, pseudoephedrine and promethazine were mentioned in fewer than 20 reports each over the 3.5 years of data examined. The FDA AERS represents a wealth of data, but there are several limitations to its use. The data are entered by the public or medical professionals, but are not checked for accuracy or completeness and may even be entered multiple times. The causal relationship between a particular adverse event and a particular medication is not tested. The cases represent a broad spectrum of demographics, occupations, and health histories, and thus do not model the astronaut population well. There is no information on the frequency of use of a medication for comparison purposes; it is not possible to assign a rate for any particular adverse event. Nonetheless, there are compelling trends. Use of corticosteroid-containing medications, pain relievers (even over-the-counter), and oral contraceptives were associated with higher numbers of vision- or intracranial pressure-related adverse events. In general, there were more vision problems than pressure problems reported. Certain medications that were once suspected of playing a role in the crew VIIP syndrome, namely pseudoephedrine and promethazine, were found to have extremely low numbers of VIIP-like AERS in the FDA data. However, crew use of corticosteroid-containing medications and pain relievers may warrant additional investigation

Faust, K. M.↗

Low Pressure Flame Blowoff from the Forward Stagnation Region of a Blunt-Nosed Cast PMMA Cylinder in Axial Mixed Convective Flow

Low-pressure blowoff experiments were conducted with a stagnation flame stabilized on the forward tip of cast PMMA rods in a vertical wind tunnel. Pressure, forced flow velocity, gravity, and ambient oxygen concentration were varied. Stagnation flame blowoff is determined from a time-stamped video recording of the test. The blowoff pressure is determined from test section pressure transducer data that is synchronized with the time stamp. The forced flow velocity is also determined from the choked flow orifice pressure. Most of the tests were performed in normal gravity, but a handful of microgravity tests were also conducted to determine the influence of buoyant flow velocity on the blowoff limits. The blowoff limits are found to have a linear dependence between the partial pressure of oxygen and the total pressure, regardless of forced flow velocity and gravity level. The flow velocity (forced and/or buoyant) affects the blowoff pressure through the critical Damkohler number residence time, which dictates the partial pressure of oxygen at blowoff. This is because the critical stretch rate increases linearly with increasing pressure at low pressure (sub-atmospheric pressures) since a second-order overall reaction rate with two-body reactions dominates in this pressure range.

flammability↗

Pressure-induced phase transitions in acentric BaHf(BO{sub 3}){sub 2}

High-pressure Raman scattering studies revealed that BaHf(BO{sub 3}){sub 2} is more compressible than calcite-type orthoborates and calcite, aragonite or dolomite carbonates. It undergoes a first-order reversible pressure-induced phase transition in the 3.9–4.4 GPa pressure range. Second structural change is observed at 9.2 GPa. The intermediate phase is most likely trigonal. However, Raman results suggest increase in the number of distinct BO{sub 3} groups from two in the ambient pressure phase to at least three in the intermediate phase. This intermediate phase is also strongly compressible and strong pressure dependence of the lattice modes proves that the main changes under pressure occur within the layers built from BaO{sub 6} and HfO{sub 6} octahedra. The second phase transition leads most likely to lowering of the trigonal symmetry, as evidenced by significant increase of the number of observed bands. The pressure coefficients of the Raman bands of the high-pressure phase are relatively small, suggesting more dense arrangement of the metal–oxygen polyhedra and BO{sub 3} groups in this phase. It is worth noting that the high-pressure phase was not reached in the second compression experiment up to 10 GPa. This behavior can be most likely attributed to worse hydrostatic conditions of the first experiment. - Graphical abstract: Raman spectra of BaHf(BO{sub 3}){sub 2} recorded at different pressures during compression showing onset of pressure-induced phase transitions. - Highlights: • High-pressure Raman spectra were measured for BaHf(BO{sub 3}){sub 2.} • BaHf(BO{sub 3}){sub 2} undergoes a reversible first-order phase transition at 3.9–4.4 GPa into a trigonal phase. • The intermediate trigonal phase is strongly compressible second structural transformation is observed at 9.2 GPa under non-perfect hydrostatic conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Capturing Pressure Oscillations in Numerical Simulations of Internal Combustion Engines

In an earlier publication, the authors compared numerical predictions of the mean cylinder pressure of diesel and dual-fuel combustion, to that of measured pressure data from a medium-speed, large-bore engine. In these earlier comparisons, measured data from a flush-mounted in-cylinder pressure transducer showed notable and repeatable pressure oscillations which were not evident in the mean cylinder pressure predictions from computational fluid dynamics (CFD). In this paper, the authors present a methodology for predicting and reporting the local cylinder pressure consistent with that of a measurement location. Such predictions for large-bore, medium-speed engine operation demonstrate pressure oscillations in accordance with those measured. The temporal occurrences of notable pressure oscillations were during the start of combustion and around the time of maximum cylinder pressure. With appropriate resolutions in time steps and mesh sizes, the local cell static pressure predicted for the transducer location showed oscillations in both diesel and dual-fuel combustion modes which agreed with those observed in the experimental data. Fast Fourier transform (FFT) analysis on both experimental and calculated pressure traces revealed that the CFD predictions successfully captured both the amplitude and frequency range of the oscillations. Furthermore, resolving propagating pressure waves with the smaller time steps and grid sizes necessary to achieve these results required a significant increase in computer resources.

33 ADVANCED PROPULSION SYSTEMS↗

High-precision measurements of the compressibility of chalcogenide glasses at a hydrostatic pressure up to 9 GPa

The volumes of glassy germanium chalcogenides GeSe{sub 2}, GeS{sub 2}, Ge{sub 17}Se{sub 83}, and Ge{sub 8}Se{sub 92} are precisely measured at a hydrostatic pressure up to 8.5 GPa. The stoichiometric GeSe{sub 2} and GeS{sub 2} glasses exhibit elastic behavior in the pressure range up to 3 GPa, and their bulk modulus decreases at pressures higher than 2–2.5 GPa. At higher pressures, inelastic relaxation processes begin and their intensity is proportional to the logarithm of time. The relaxation rate for the GeSe{sub 2} glasses has a pronounced maximum at 3.5–4.5 GPa, which indicates the existence of several parallel structural transformation mechanisms. The nonstoichiometric glasses exhibit a diffuse transformation and inelastic behavior at pressures above 1–2 GPa. The maximum relaxation rate in these glasses is significantly lower than that in the stoichiometric GeSe{sub 2} glasses. All glasses are characterized by the “loss of memory” of history: after relaxation at a fixed pressure, the further increase in the pressure returns the volume to the compression curve obtained without a stop for relaxation. After pressure release, the residual densification in the stoichiometric glasses is about 7% and that in the Ge{sub 17}Se{sub 83} glasses is 1.5%. The volume of the Ge{sub 8}Se{sub 92} glass returns to its initial value within the limits of experimental error. As the pressure decreases, the effective bulk moduli of the Ge{sub 17}Se{sub 83} and Ge{sub 8}Se{sub 92} glasses coincide with the moduli after isobaric relaxation at the stage of increasing pressure, and the bulk modulus of the stoichiometric GeSe{sub 2} glass upon decreasing pressure noticeably exceeds the bulk modulus after isobaric relaxation at the stage of increasing pressure. Along with the reported data, our results can be used to draw conclusions regarding the diffuse transformations in glassy germanium chalcogenides during compression.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fresh Water Generation from Aquifer-Pressured Carbon Storage: Interim Progress Report

This project is establishing the potential for using brine pressurized by Carbon Capture and Storage (CCS) operations in saline formations as the feedstock for desalination and water treatment technologies including nanofiltration (NF) and reverse osmosis (RO). The aquifer pressure resulting from the energy required to inject the carbon dioxide provides all or part of the inlet pressure for the desalination system. Residual brine would be reinjected into the formation at net volume reduction. This process provides additional storage space (capacity) in the aquifer, reduces operational risks by relieving overpressure in the aquifer, and provides a source of low-cost fresh water to offset costs or operational water needs. Computer modeling and laboratory-scale experimentation are being used to examine mineral scaling and osmotic pressure limitations for brines typical of CCS sites. Computer modeling is being used to evaluate processes in the aquifer, including the evolution of the pressure field. This progress report deals mainly with our geochemical modeling of high-salinity brines and covers the first six months of project execution (September, 2008 to March, 2009). Costs and implementation results will be presented in the annual report. The brines typical of sequestration sites can be several times more concentrated than seawater, requiring specialized modeling codes typical of those developed for nuclear waste disposal calculations. The osmotic pressure developed as the brines are concentrated is of particular concern, as are precipitates that can cause fouling of reverse osmosis membranes and other types of membranes (e.g., NF). We have now completed the development associated with tasks (1) and (2) of the work plan. We now have a contract with Perlorica, Inc., to provide support to the cost analysis and nanofiltration evaluation. We have also conducted several preliminary analyses of the pressure effect in the reservoir in order to confirm that reservoir pressure can indeed be used to drive the reverse osmosis process. Our initial conclusions from the work to date are encouraging: (1) The concept of aquifer-pressured RO to provide fresh water associated with carbon dioxide storage appears feasible. (2) Concentrated brines such as those found in Wyoming are amenable to RO treatment. We have looked at sodium chloride brines from the Nugget Formation in Sublette County. 20-25% removal with conventional methods is realistic; higher removal appears achievable with NF. The less concentrated sulfate-rich brines from the Tensleep Formation in Sublette County would support >80% removal with conventional RO. (3) Brines from other proposed sequestration sites can now be analyzed readily. An osmotic pressure curve appropriate to these brines can be used to evaluate cost and equipment specifications. (4) We have examined a range of subsurface brine compositions that is potentially pertinent to carbon sequestration and noted the principal compositional trends pertinent to evaluating the feasibility of freshwater extraction. We have proposed a general categorization for the feasibility of the process based on total dissolved solids (TDS). (5) Withdrawing pressurized brine can have a very beneficial effect on reservoir pressure and total available storage capacity. Brine must be extracted from a deeper location in the aquifer than the point of CO{sub 2} injection to prevent CO{sub 2} from migrating to the brine extraction well.

02 PETROLEUM↗

Ball tonometry: a rapid, nondestructive method for measuring cell turgor pressure in thin-walled plant cells

In this article we describe a new method for the determination of turgor pressures in living plant cells. Based on the treatment of growing plant cells as thin-walled pressure vessels, we find that pressures can be accurately determined by observing and measuring the area of the contact patch formed when a spherical glass probe is lowered onto the cell surface with a known force. Within the limits we have described, we can show that the load (determined by precalibration of the device) divided by the projected area of the contact patch (determined by video microscopy) provides a direct, rapid, and accurate measure of the internal turgor pressure of the cell. We demonstrate, by parallel measurements with the pressure probe, that our method yields pressure data that are consistent with those from the pressure probe. Also, by incubating target tissues in stepped concentrations of mannitol to incrementally reduce the turgor pressure, we show that the pressures measured by tonometry accurately reflect the predicted changes from the osmotic potential of the bathing medium. The advantages of this new method over the pressure probe are considerable, however, in that we can move rapidly from cell to cell, taking measurements every 20 s. In addition, the nondestructive nature of the method means that we can return to the same cell repeatedly for periodic pressure measurements. The limitations of the method lie in the fact that it is suitable only for superficial cells that are directly accessible to the probe and to cells that are relatively thin walled and not heavily decorated with surface features. It is also not suitable for measuring pressures in flaccid cells.

NASA Discipline Plant Biology↗

Pressure-induced phase transition on K{sub 2}MoO{sub 4}: A Raman scattering study and ab initio calculations

This work reports high pressure Raman scattering results on dipotassium molybdate (K{sub 2}MoO{sub 4}). The effects of hydrostatic pressure on the vibrational properties of K{sub 2}MoO{sub 4} has been investigated in the pressure range from 0.5 to 7.3 GPa. This study also indicates that K{sub 2}MoO{sub 4} crystals exhibit a pressure-induced first-order phase transition at about 2.2 GPa from monoclinic to an unknown symmetry. Calculaions based on density-functional theory (DFT) unveiled the structural changes undergone by the K{sub 2}MoO{sub 4} system under hydrostatic pressure. The phase transition is connected with the increase of the polyhedral KO{sub 6} distortion due to an increased anionic interaction as volume decrease, therefore leading to tiltings and/or rotations of the MoO{sub 4} tetrahedra. The consequence of such tiltings and/or rotations of the MoO{sub 4} tetrahedra is to increase the disorder of these units. The high-pressure phase transforms directly into the ambient-pressure phase as pressure is released. - Graphical Abstract: Dipotassium molybdate (K{sub 2}MoO{sub 4}) belongs to the class of single molybdates and tungstates with a general composition of the A{sub 2}MO{sub 4} (A=Li, Na, K, Rb, Cs; {Mu}=Mo, W). At room temperature and ambient pressure, the crystal of K{sub 2}MoO{sub 4} is monoclinic and it belongs to the C2/m (C{sub 2h}{sup 3}) space group. This material is attracting a considerable attention due to its interesting structural and thermodynamic properties. This work reports a high pressure study on this system. Highlights: Black-Right-Pointing-Pointer We reports high pressure Raman scattering results on dipotassium molybdate. Black-Right-Pointing-Pointer Our study indicates a pressure-induced first-order phase transition at around 2.16 GPa. Black-Right-Pointing-Pointer DFT calculations indicate that phase transition is connected with the increase of KO{sub 6} distortion. Black-Right-Pointing-Pointer Tiltings and/or rotations of the MoO{sub 4} tetrahedra are related to increased disorder.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pressure-induced amorphization of La{sub 1/3}TaO{sub 3}

La{sub 1/3}TaO{sub 3}, an A-site cation deficient perovskite, has been studied under pressure by synchrotron X-ray powder diffraction and Raman spectroscopy. It undergoes irreversible pressure induced amorphization at P=18.5 GPa. An almost linear unit cell volume decrease vs. pressure is observed from ambient pressure up to the phase transition. The Raman spectroscopy also shows amorphization at the same pressure, with positive shifts of all modes as a function of pressure. The pressure dependence of the E{sub g} and A{sub 1g} Raman modes arising from the octahedral oxygen network is discussed. - Graphical abstract: La{sub 1/3}Tao{sub 3} exhibits linear pressure–volume relation until irreversible pressure induced amorphization at 18.5 Gpa. - Highlights: • La{sub 1/3}TaO{sub 3} has been studied under pressure by synchrotron XRD and Raman spectroscopy. • La{sub 1/3}TaO{sub 3} undergoes irreversible pressure induced amorphization around 18.5 GPa. • The transition is manifested in both XRD and Raman measurements. • A linear P–V relation is observed from ambient pressure up to the phase transition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High pressure powder X-ray diffraction of sillenites Bi{sub 12}MO{sub 20} (M=Si, Ge, Ti) and Bi{sub 4}Ti{sub 3}O{sub 12}

Powder X-ray diffraction experiments of sillenites Bi{sub 12}M O{sub 20} (M=Si, Ge, Ti) were performed with synchrotron radiation at the ESRF, Grenoble, at pressures up to 39 GPa (M=Si), 50 GPa (M=Ge), and 37 GPa (M=Ti), respectively. These three sillenites were investigated for the first time over such a large pressure range and they show no phase transition up to the highest pressures achieved. Birch–Murnaghan equations of state of third order were fitted to the pressure dependence of the lattice parameters. The resulting bulk moduli B{sub 0} and their pressure derivatives B′ are B{sub 0}=63(1)GPa with B′=6.6(3) (M=Si), B{sub 0}=63.0(5)GPa with B′=5.90(7) (M=Ge), and B{sub 0}=48(1)GPa with B′=9.4(5) (M=Ti). In the case of Bi{sub 12}SiO{sub 20} and Bi{sub 12}TiO{sub 20} the equation of state fits were restricted to pressures below 15 GPa, because the experimental data were affected by non-hydrostatic stress at higher pressures. The equation of state of neon was redetermined (V{sub 0}=11.7(6)cm{sup 3}/mol, B{sub 0}=5(1)GPa, B′=5.5(3)GPa) and its use as an internal pressure standard for diffraction experiments is discussed. A second cubic phase could be identified in our Bi{sub 12}TiO{sub 20} sample. This was attributed to eulytite-type Bi{sub 4}Ti{sub 3}O{sub 12}, which has B{sub 0}=50.9(8)GPa and B′=6.9(3). - Graphical abstract: X-ray diffraction at high pressure → Equation of state. - Highlights: • Powder X-ray diffraction experiments of sillenites were performed at high pressures. • Equations of state of sillenites Bi{sub 12}MO{sub 20} (M=Si, Ge, Ti) were determined. • The sillenite structure was shown to be stable at high hydrostatic pressure. • Sillenites are sensitive to non-hydrostatic pressure conditions in neon-loaded DACs. • An eulytite-type Bi{sub 4}Ti{sub 3}O{sub 12} phase was found to exist up to 10 GPa.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗