Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

VAPRE: A tool to support the design optimization of planetary entry probe missions

The importance of the atmospheric data collected by planetary entry probes has been emphasized since the results of Galileo in 1995 and are reflected in the interest . The results add to our fundamental understanding about the formation and the evolution of our solar system. Of special interest are the Outer Planets Saturn, Uranus and Neptune, serving as missing puzzle pieces to the existing data sets. In order to maximize the data and science return from those missions, the tool VAPRE is developed to facilitate the design optimization of planetary entry probe missions by increasing the trade-space. Using a data set of interplanetary trajectories, it assesses the change in availability and accessibility of entry sites on the planets with respect to their latitudes depending on the hyperbolic arrival velocity. In this paper, we introduce the motivation behind the implementation of VAPRE, the science and engineering input gathered to bridge the knowledge between both fields, the design structure of the implementation as well as the significance and future development and potential of the tool VAPRE for future mission concept developments for planetary probe and lander missions.

Simon, Amy↗

Flagship-Class Uranus Orbiter and Probe Using Aerocapture

Exploration of the Ice Giants, especially Uranus, via orbiter and atmospheric probes, is required to answer pressing science questions that have been raised in the latest Decadal Survey. As the Ice Giants are the farthest planets from Earth, traditional fully-propulsive orbit insertion missions have transit times to the planetary bodies nearing 13-15 years and require a large amount of propellant (wet mass percentages of around 60-70%) for the orbit insertion maneuver, leaving less mass for the scientific payload and a planetary probe. Aerocapture uses aerodynamic forces generated by flight within a planetary atmosphere to decelerate and achieve orbit insertion. Aerocapture has been considered for several past missions but it has not been demonstrated. However, recent developments in thermal protection systems (TPS), guidance and control (G&C), and interplanetary navigation capabilities show the potential for using rigid, heritage entry vehicle configurations already flown at other planetary bodies for Ice Giants aerocapture. Aerocapture can robustly deliver spacecraft to Ice Giant orbits, while substantially increasing on-orbit payload mass (more than 40%) that can be used for a robust atmospheric entry probe. Additionally, the aerocapture maneuver would reduce the interplanetary transit time by 2-5 years (15-30%) relative to fully-propulsive orbit insertion. Recent work has shown that a flagship-class mission can be conducted in a shorter time than fully-propulsive missions if using aerocapture.

S Dutta↗

On the Mesoscale Structure of Coronal Mass Ejections at Mercury’s Orbit: BepiColombo and Parker Solar Probe Observations

On 2022 February 15, an impressive filament eruption was observed off the solar eastern limb from three remote-sensing viewpoints, namely, Earth, STEREO-A, and Solar Orbiter. In addition to representing the most-distant observed filament at extreme ultraviolet wavelengths—captured by Solar Orbiter's field of view extending to above 6 R ⊙ —this event was also associated with the release of a fast (∼2200 km s −1 ) coronal mass ejection (CME) that was directed toward BepiColombo and Parker Solar Probe. These two probes were separated by 2° in latitude, 4° in longitude, and 0.03 au in radial distance around the time of the CME-driven shock arrival in situ. The relative proximity of the two probes to each other and the Sun (∼0.35 au) allows us to study the mesoscale structure of CMEs at Mercury's orbit for the first time. We analyze similarities and differences in the main CME-related structures measured at the two locations, namely, the interplanetary shock, the sheath region, and the magnetic ejecta. We find that, despite the separation between the two spacecraft being well within the typical uncertainties associated with determination of CME geometric parameters from remote-sensing observations, the two sets of in situ measurements display some profound differences that make understanding the overall 3D CME structure particularly challenging. Finally, we discuss our findings within the context of space weather at Mercury's distance and in terms of the need to investigate solar transients via spacecraft constellations with small separations, which has been gaining significant attention during recent years.

Erika Palmerio↗

Methods for radiation detection and characterization using a multiple detector probe

Apparatuses, methods, and systems relating to radiological characterization of environments are disclosed. Multi-detector probes with a plurality of detectors in a common housing may be used to substantially concurrently detect a plurality of different radiation activities and types. Multiple multi-detector probes may be used in a down-hole environment to substantially concurrently detect radioactive activity and contents of a buried waste container. Software may process, analyze, and integrate the data from the different multi-detector probes and the different detector types therein to provide source location and integrated analysis as to the source types and activity in the measured environment. Further, the integrated data may be used to compensate for differential density effects and the effects of radiation shielding materials within the volume being measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct and quantitative broadband absorptance spectroscopy with multilayer cantilever probes

A system for measuring the absorption spectrum of a sample is provided that includes a broadband light source that produces broadband light defined within a range of an absorptance spectrum. An interferometer modulates the intensity of the broadband light source for a range of modulation frequencies. A bi-layer cantilever probe arm is thermally connected to a sample arm having at most two layers of materials. The broadband light modulated by the interferometer is directed towards the sample and absorbed by the sample and converted into heat, which causes a temperature rise and bending of the bi-layer cantilever probe arm. A detector mechanism measures and records the deflection of the probe arm so as to obtain the absorptance spectrum of the sample.

36 MATERIALS SCIENCE↗

Band excitation method applicable to scanning probe microscopy

Scanning probe microscopy may include a method for generating a band excitation (BE) signal and simultaneously exciting a probe at a plurality of frequencies within a predetermined frequency band based on the excitation signal. A response of the probe is measured across a subset of frequencies of the predetermined frequency band and the excitation signal is adjusted based on the measured response.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Band excitation method applicable to scanning probe microscopy

Scanning probe microscopy may include a method for generating a band excitation (BE) signal and simultaneously exciting a probe at a plurality of frequencies within a predetermined frequency band based on the excitation signal. A response of the probe is measured across a subset of frequencies of the predetermined frequency band and the excitation signal is adjusted based on the measured response.

47 OTHER INSTRUMENTATION↗

Positron emission tomography probe to monitor selected sugar metabolism in vivo

The invention disclosed herein discloses selected ribose isomers that are useful as PET probes (e.g. [18F]-2-fluoro-2-deoxy-arabinose). These PET probes are useful, for example, in methods designed to monitor physiological processes including ribose metabolism and/or to selectively observe certain tissue/organs in vivo. The invention disclosed herein further provides methods for making and using such probes.

47 OTHER INSTRUMENTATION↗

Detection of protease and protease activity using a single nanocrescent SERS probe

This invention pertains to the in vitro detection of proteases using a single peptide-conjugate nanocrescent surface enhanced Raman scattering (SERS) probes with at least nanomolar sensitivity. The probe enables detection of proteolytic activity in extremely small volume and at low concentration. In certain embodiments the probes comprise an indicator for the detection of an active protease, where the indicator comprises a nanocrescent attached to a peptide, where said peptide comprises a recognition site for the protease and a Raman tag attached to the peptide.

47 OTHER INSTRUMENTATION↗

Dark Energy Survey Year 1 Results: Multi-Probe Methodology and Simulated Likelihood Analyses

We present the methodology for and detail the implementation of the Dark Energy Survey (DES) 3x2pt DES Year 1 (Y1) analysis, which combines configuration-space two-point statistics from three different cosmological probes: cosmic shear, galaxy-galaxy lensing, and galaxy clustering, using data from the first year of DES observations. We have developed two independent modeling pipelines and describe the code validation process. We derive expressions for analytical real-space multi-probe covariances, and describe their validation with numerical simulations. We stress-test the inference pipelines in simulated likelihood analyses that vary 6-7 cosmology parameters plus 20 nuisance parameters and precisely resemble the analysis to be presented in the DES 3x2pt analysis paper, using a variety of simulated input data vectors with varying assumptions. We find that any disagreement between pipelines leads to changes in assigned likelihood $\Delta \chi^2 \le 0.045$ with respect to the statistical error of the DES Y1 data vector. We also find that angular binning and survey mask do not impact our analytic covariance at a significant level. We determine lower bounds on scales used for analysis of galaxy clustering (8 Mpc$~h^{-1}$) and galaxy-galaxy lensing (12 Mpc$~h^{-1}$) such that the impact of modeling uncertainties in the non-linear regime is well below statistical errors, and show that our analysis choices are robust against a variety of systematics. These tests demonstrate that we have a robust analysis pipeline that yields unbiased cosmological parameter inferences for the flagship 3x2pt DES Y1 analysis. We emphasize that the level of independent code development and subsequent code comparison as demonstrated in this paper is necessary to produce credible constraints from increasingly complex multi-probe analyses of current data.

79 ASTRONOMY AND ASTROPHYSICS↗

Capture probe

A system for sampling a sample material includes a device for directing sample into a capture probe. A probe includes an outer probe housing having an open end. A liquid supply conduit has an outlet positioned to deliver liquid to the open end. An exhaust conduit removes liquid from the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust system can be in fluid connection with the liquid exhaust conduit for removing liquid from the liquid exhaust conduit at a second volumetric flow rate, which exceeds the first volumetric flow rate such that gas with sample is withdrawn with the liquid.

36 MATERIALS SCIENCE↗

Advanced radio frequency sensing probe

A radio-frequency probe system with a transmitting or receiving element integrated into a cable assembly is disclosed. In some embodiments a preferred configuration may contain one or more sensing elements integrated into the transmitting or receiving element. In another embodiment, the radio frequency probe comprises an antenna body fixed to a coaxial cable, in which the center conductor of the coaxial cable serves as the transmitting or receiving element. A method for monitoring, transmitting, or detecting one or more parameters using a single radio frequency probe is also disclosed.

47 OTHER INSTRUMENTATION↗

Probing nucleon's spin structures with polarized Drell-Yan in the Fermilab SpinQuest experiment

Although the proton was discovered about 100 years ago, its spin structure still remains a mystery. Recent studies suggest that the orbital angular momentum of sea quarks could significantly contribute to the proton's spin. The SeaQuest experiment, which recently completed data collection, probed the unpolarized light quark sea distributions of the proton using the Drell-Yan process. Its successor, the SpinQuest (E1039), will access the $\bar{u}$ and $\bar{d}$ Sivers functions using polarized NH$_3$ and ND$_3$ targets. A non-zero Sivers asymmetry, observed in SpinQuest, would be a strong indication of non-zero sea-quark orbital angular momentum. The SpinQuest experiment can also probe the sea quark's transversity distribution, which is relevant for the determination of proton's tensor charge. Recent study suggests that sea-quarks might contribute significantly to deuteron's tensor polarized structure functions. This can be further probed in SpinQuest using tensor polarized ND$_3$ target. The current status and future plan of the experiment are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modified eddy current probe for low conductivity surfaces

A modified eddy current (MEC) probe includes a probe body having a bore formed therein. A printed circuit board (PCB) assembly includes a circuit board defining a plane, has a plurality of electronic components mounted thereon, and is configured for mounting within the bore of the probe body. A coil board assembly is electrically connected to the PCB assembly and comprises a coil board defining a plane, a transmitter coil formed on a first side of the coil board, and a sensor coil formed on second side of the coil board. The plane of the coil board is arranged orthogonally to the plane of the circuit board.

42 ENGINEERING↗

Modified eddy current probe having a faraday shield

A modified eddy current (MEC) probe includes a probe body having a bore formed therein. A printed circuit board (PCB) assembly includes a circuit board defining a plane, has a plurality of electronic components mounted thereon, and is configured for mounting within the bore of the probe body. A coil board assembly is electrically connected to the PCB assembly, defines a plane, and includes a first coil board layer, a second coil board layer bonded to the first coil board layer, a transmitter coil formed on an outside surface of the first coil board layer, a Faraday shield formed on an outside surface of the second coil board layer, and a sensor coil formed on one of an inside surface of the first coil board layer and the second coil board layer, such that the sensor coil is positioned between the first coil board layer and the second coil board layer. The plane of the coil board assembly is arranged orthogonally to the plane of the circuit board.

47 OTHER INSTRUMENTATION↗

Method for error correction in scanning probe microscopy

Disclosed here is a scanning probe microscope system and method for operating the same for producing scanning probe microscope images at fast scan rates and reducing oscillation artifacts. In some embodiments, an inverse consistent image registration method is used to align forward and backward scan traces for each line of the scanning microscope image. In some embodiments, the aligned forward and backward scan traces are combined using a weighting factor favoring the scan trace with higher smoothness. In some embodiments, the scanning probe microscope image is a potentiometry map and a method is provided to extract from the potentiometry map a conductivity map.

47 OTHER INSTRUMENTATION↗

Capture probe

A system for sampling a sample material includes a device for directing sample into a capture probe. A probe includes an outer probe housing having an open end. A liquid supply conduit has an outlet positioned to deliver liquid to the open end. An exhaust conduit removes liquid from the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust system can be in fluid connection with the liquid exhaust conduit for removing liquid from the liquid exhaust conduit at a second volumetric flow rate, which exceeds the first volumetric flow rate such that gas with sample is withdrawn with the liquid.

42 ENGINEERING↗

Advanced radio frequency sensing probe

A radio-frequency probe system with a transmitting or receiving element integrated into a cable assembly is disclosed. In some embodiments a preferred configuration may contain one or more sensing elements integrated into the transmitting or receiving element. In another embodiment, the radio frequency probe comprises an antenna body fixed to a coaxial cable, in which the center conductor of the coaxial cable serves as the transmitting or receiving element. A method for monitoring, transmitting, or detecting one or more parameters using a single radio frequency probe is also disclosed.

Sappok, Alexander↗