Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

The phase-2 particle x-ray temporal diagnostic for simultaneous measurement of multiple x-ray and nuclear emission histories from OMEGA implosions (invited)

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as T e is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (~15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated T e (t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium- 3 He protons (D 3 Hep). A future upgrade to the system will enable spatially integrated T e (t) with 40 ps time-resolution from cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of Neutron Multiplicity Counting Experiments to Optimal Cross-Section Adjustments

This paper presents the first application of model calibration to neutron multiplicity counting (NMC) experiments for cross-section optimization that is informed by adjoint-based sensitivity analysis (SA) and first-order uncertainty quantification (UQ). We summarize previous work on SA applied to NMC and describe notable modifications and additions. We give the procedure for first-order UQ and Bayesian-inference-based parameter estimation (PE). We then discuss model calibration applied to NMC of a 4.5-kg sphere of weapons-grade, alpha-phase plutonium metal (the BeRP ball) with the nPod neutron multiplicity counter. For the BeRP ball in bare and polyethylene-reflected configurations, we discuss the sensitivity of the first- and second-moment detector responses (i.e., first and second moments of the NMC distribution, respectively) to the cross sections. We describe the sources of uncertainty in the measured and simulated responses. Specifically, uncertainty in the measured responses is due to both random and systematic sources. Uncertainty in the simulated responses is due to the cross-section covariances. We describe in detail the adjustment to the cross sections and cross-section covariances due to the optimization. Due to the contribution of systematic uncertainties to the measured response uncertainties, the adjustment to the cross sections is similar in trend but larger in magnitude compared to that recommended by previous work. We compare the measured responses to responses simulated with nominal and optimized cross sections, demonstrating that the best-estimate cross sections produce simulations of NMC experiments that are more accurate with reduced uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A NEW 24 {mu}m PHASE CURVE FOR {upsilon} ANDROMEDAE b

We report the detection of 24 {mu}m variations from the planet-hosting {upsilon} Andromedae system consistent with the orbital periodicity of the system's innermost planet, {upsilon} And b. We find a peak-to-valley phase curve amplitude of 0.00130 times the mean system flux. Using a simple model with two hemispheres of constant surface brightness and assuming a planetary radius of 1.3 R{sub J} give a planetary temperature contrast of {approx}>900 K and an orbital inclination of {approx}>28{sup 0}. We further report the largest phase offset yet observed for an extrasolar planet: the flux maximum occurs {approx}80{sup 0} before phase 0.5. Such a large phase offset is difficult to reconcile with most current atmospheric circulation models. We improve on earlier observations of this system in several important ways: (1) observations of a flux calibrator star demonstrate the MIPS detector is stable to 10{sup -4} on long timescales, (2) we note that the background light varies systematically due to spacecraft operations, precluding use of this background as a flux calibrator (stellar flux measured above the background is not similarly affected), and (3) we calibrate for flux variability correlated with motion of the star on the MIPS detector. A reanalysis of our earlier observations of this system is consistent with our new result.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization and QC practice of 16-channel ADC ASIC at cryogenic temperature for Liquid Argon TPC front-end readout electronics system in DUNE experiment

ColdADC is a low-noise 16-channel analog-to-digital converter ASIC designed for cold readout electronics of Liquid Argon Time Projection Chambers (LArTPCs) in the Deep Underground Neutrino Experiment (DUNE). ColdADC was specifically designed for operation at cryogenic temperatures (77 K–89 K). Cold electronics is considered to be an enabling technology for liquid argon detectors in neutrino experiments. The main function of the chip is to digitize signals from the 16-channel charge-sensitive amplifier designed at BNL (LArASIC) and send digitized signals to the data aggregator and serializer chip (COLDATA). ColdADC operates with a resolution of 12 bits and a sampling rate of 2 MS/s per channel. A complete characterization of prototype chips was conducted at cryogenic temperature, involving power consumption, noise and linearity performance. In the first DUNE Far-Detector module, 384000 data channels will be read out, corresponding to 24000 ColdADC chips. Therefore, systematic testing of ColdADC chips at cryogenic temperature is vital for the quality and reliability of DUNE Single-Phase modules. We have developed a Quality Control (QC) test stand that includes ColdADC evaluation and characterization at cryogenic temperature. The QC procedure was applied to a first batch of 33 chips, corresponding to 528 data channels. The obtained results meet all the required DUNE specifications for ColdADC. Moreover, the testing outcome allowed us to identify possibilities of performance optimization that are currently being addressed in the design of the next version of the chip. The Quality Control procedure is proved to be successful and will be a reference design for future large-batch production testing of final ColdADC ASICs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum nondemolition photon detection in circuit QED and the quantum Zeno effect

We analyze the detection of itinerant photons using a quantum nondemolition measurement. An important example is the dispersive detection of microwave photons in circuit quantum electrodynamics, which can be realized via the nonlinear interaction between photons inside a superconducting transmission line resonator. We show that the back action due to the continuous measurement imposes a limit on the detector efficiency in such a scheme. We illustrate this using a setup where signal photons have to enter a cavity in order to be detected dispersively. In this approach, the measurement signal is the phase shift imparted to an intense beam passing through a second cavity mode. The restrictions on the fidelity are a consequence of the quantum Zeno effect, and we discuss both analytical results and quantum trajectory simulations of the measurement process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of the Υ ( 10860 ) and Υ ( 11020 ) resonances via σ ( e + e - → Υ ( n S ) π + π - )

In this work, we report new measurements of the total cross sections for e + e - → Υ ( n S ) π + π - ( n = 1 , 2, 3) and e + e - → b b ¯ from a high-luminosity fine scan of the region s = 10.63 – 11.05 GeV with the Belle detector. We observe that the Υ ( n S ) π + π - spectra have little or no nonresonant component and extract from them the masses and widths of Υ ( 10860 ) and Υ ( 11020 ) and their relative phase. We find M 10860 = ( 10891.1 ± 3. 2 - 1.7 + 0.6 ) MeV / c 2 and Γ 10860 = ( 53. 7 - 5.6 - 5.4 + 7.1 + 1.3 ) MeV and report first measurements M 11020 = ( 10987. 5 - 2.5 - 2.1 + 6.4 + 9.0 ) MeV / c 2 , Γ 11020 = ( 6 1 - 19 - 20 + 9 + 2 ) MeV , and Φ 11020 - Φ 10860 = ( - 1.0 ± 0.4 - 0.1 + 1.4 ) rad .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for a Nonrelativistic Boson in Two-Body Antimuon Decay

We demonstrate the feasibility of probing the charged lepton-flavor-violating decay μ + → e + X 0 for the presence of a slow-moving neutral boson X 0 capable of undergoing gravitational binding to large structures and, as such, able to participate in some cosmological scenarios. A short exposure to surface antimuons from beam line M20 at TRIUMF generates a branching ratio limit of ≲ 10 –5 . This is comparable to or better than previous searches for this channel, although in a thus-far-unexplored region of X 0 phase space very close to the kinematic limit of the decay, where m X 0 approaches m μ+ . The future improved sensitivity of the method using a customized p -type point-contact germanium detector is described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the polarization correlation parameter C{sub nn} in the pp elastic scattering with an unpolarized proton target and an unpolarized 1-GeV proton beam

The polarization correlation parameter C{sub nn} in the elastic proton-proton scattering was for the first time measured with a high statistical accuracy at 1 GeV using an unpolarized proton beam incident on an unpolarized proton target. Both outgoing protons from the reaction were detected in coincidence by means of a two-arm focusing magnetic spectrometer installed at nonsymmetric angles corresponding to the center-of-mass scattering angle {Theta}{sub cm} = 62.25{sup o}. The correlation parameter C{sub nn}, as well as polarizations P{sub 1} and P{sub 2} of the secondary protons, were measured by means of multiwire proportional chamber polarimeters placed at the focal planes of each spectrometer arm. The obtained data are compared with the predictions of the phase-shift analysis. The connection with the experiment on C{sub nn} and polarization measurements in the (p, 2p) reaction on {sup 4}He and other light nuclei in similar kinematics is discussed

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Muon reconstruction and identification efficiency in ATLAS using the full Run 2 $pp$ collision data set at $\sqrt{s}=13$ TeV

This article documents the muon reconstruction and identification efficiency obtained by the ATLAS experiment for 139 fb$^{-1}$ of $pp$ collision data at $\sqrt{s}=13$ TeV collected between 2015 and 2018 during Run 2 of the LHC. The increased instantaneous luminosity delivered by the LHC over this period required a reoptimisation of the criteria for the identification of prompt muons. Improved and newly developed algorithms were deployed to preserve high muon identification efficiency with a low misidentification rate and good momentum resolution. The availability of large samples of $Z\to\mu\mu$ and $J/\psi\to\mu\mu$ decays, and the minimisation of systematic uncertainties, allows the efficiencies of criteria for muon identification, primary vertex association, and isolation to be measured with an accuracy at the per-mille level in the bulk of the phase space, and up to the percent level in complex kinematic configurations. Excellent performance is achieved over a range of transverse momenta from 3 GeV to several hundred GeV, and across the full muon detector acceptance of $|\eta|<2.7$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Initial measurement of reactor antineutrino oscillation at SNO+

The SNO+ collaboration reports its first spectral analysis of long-baseline reactor antineutrino oscillation using 114 tonne-years of data. Fitting the neutrino oscillation probability to the observed energy spectrum yields constraints on the neutrino mass-squared difference Δ$m^2_{21}$. In the ranges allowed by previous measurements, the best-fit Δ$m^2_{21}$ is ($8.85^{+1.10}_{-1.33}$) × 10 -5 eV 2 . This measurement is continuing in the next phases of SNO+ and is expected to surpass the present global precision on Δ$m^2_{21}$ with about three years of data. In the following, we first describe the configuration of the SNO+ detector when it was partially filled with scintillator, and a characterization of the detector response using intrinsic radioactivity. Next, we detail the event selection and expectations for reactor IBDs and (α, n) reactions. Then, we present the results of an energy spectrum analysis using 114 tonne-years of data. We conclude with prospects of future results from the SNO+ detector, which has been operating fully-filled with 780 tonnes of scintillator

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extraction of CP Properties of the H(125) Boson Discovered in Proton-Proton Collisions at√s = 7 and 8 TeV with the CMS Detector at the LHC

In this thesis we build a novel analysis framework to perform the direct extraction ofall possible effective Higgs boson couplings to the neutral electroweak gauge bosonsin the H → ZZ (*) → 4 channel also referred to as the golden channel. We use analytic expressions of the full decay differential cross sections for the H → V V → 4process, and the dominant irreducible standard model q q → 4 background where¯4 = 2e2µ, 4e, 4µ. Detector effects are included through an explicit convolution ofthese analytic expressions with transfer functions that model the detector responsesas well as acceptance and efficiency effects. Using the full set of decay observables, weconstruct an unbinned 8-dimensional detector level likelihood function which is continuous in the effective couplings, and includes systematics. All potential anomalouscouplings of HV V where V = Z, γ are considered, allowing for general CP even/oddadmixtures and any possible phases. We measure the CP -odd mixing between thetree-level HZZ coupling and higher order CP -odd couplings to be compatible withzero, and in the range [-0.40, 0.43], and the mixing between HZZ tree-level couplingand higher order CP -even coupling to be in the ranges [-0.66, -0.57] U [-0.15, 1.00];namely compatible with a standard model Higgs. We discuss the expected precisionin determining the various HV V couplings in future LHC runs. A powerful and at first glance surprising prediction of the analysis is that with 100-400 fb -1 , the goldenchannel will be able to start probing the couplings of the Higgs boson to diphotons inthe 4 channel. We discuss the implications and further optimization of the methodsfor the next LHC runs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Standard Model Physics at the HL-LHC and HE-LHC

The successful operation of the Large Hadron Collider (LHC) and the excellent performance of the ATLAS, CMS, LHCb and ALICE detectors in Run-1 and Run-2 with $pp$ collisions at center-of-mass energies of 7, 8 and 13 TeV as well as the giant leap in precision calculations and modeling of fundamental interactions at hadron colliders have allowed an extraordinary breadth of physics studies including precision measurements of a variety physics processes. The LHC results have so far confirmed the validity of the Standard Model of particle physics up to unprecedented energy scales and with great precision in the sectors of strong and electroweak interactions as well as flavour physics, for instance in top quark physics. The upgrade of the LHC to a High Luminosity phase (HL-LHC) at 14 TeV center-of-mass energy with 3 ab$^{-1}$ of integrated luminosity will probe the Standard Model with even greater precision and will extend the sensitivity to possible anomalies in the Standard Model, thanks to a ten-fold larger data set, upgraded detectors and expected improvements in the theoretical understanding. This document summarises the physics reach of the HL-LHC in the realm of strong and electroweak interactions and top quark physics, and provides a glimpse of the potential of a possible further upgrade of the LHC to a 27 TeV $pp$ collider, the High-Energy LHC (HE-LHC), assumed to accumulate an integrated luminosity of 15 ab$^{-1}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Research on data from the ATLAS experiment at CERN

In this report senior investigator Prof. Milind V. Purohit describes research done with data from the ATLAS experiment at CERN. This includes preparing papers on the performance of the CSC detector, searches for SUSY using a new modern ''big data'' technique, and a search for supersymmetry (SUSY) using the "zero leptons razor" (0LRaz) technique. The prediction of the W=Z+jets background processes by the ATLAS simulation prior to the fit is found to be overestimated in the phase space of interest. In all new signal regions presented in this analysis the number of events observed is consistent with the post-fit SM expectations. Assuming R-parity conservation, the limit on the gluino mass exceeds 1150 GeV at 95% confidence level, for an LSP mass smaller than 100 GeV. Other USC personnel who participated in this project during the period of this grant were a graduate student, Anton Kravchenko.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TH-EF-207A-05: Feasibility of Applying SMEIR Method On Small Animal 4D Cone Beam CT Imaging

Purpose: Small animal cone beam CT imaging has been widely used in preclinical research. Due to the higher respiratory rate and heat beats of small animals, motion blurring is inevitable and needs to be corrected in the reconstruction. Simultaneous motion estimation and image reconstruction (SMEIR) method, which uses projection images of all phases, proved to be effective in motion model estimation and able to reconstruct motion-compensated images. We demonstrate the application of SMEIR for small animal 4D cone beam CT imaging by computer simulations on a digital rat model. Methods: The small animal CBCT imaging system was simulated with the source-to-detector distance of 300 mm and the source-to-object distance of 200 mm. A sequence of rat phantom were generated with 0.4 mm{sup 3} voxel size. The respiratory cycle was taken as 1.0 second and the motions were simulated with a diaphragm motion of 2.4mm and an anterior-posterior expansion of 1.6 mm. The projection images were calculated using a ray-tracing method, and 4D-CBCT were reconstructed using SMEIR and FDK methods. The SMEIR method iterates over two alternating steps: 1) motion-compensated iterative image reconstruction by using projections from all respiration phases and 2) motion model estimation from projections directly through a 2D-3D deformable registration of the image obtained in the first step to projection images of other phases. Results: The images reconstructed using SMEIR method reproduced the features in the original phantom. Projections from the same phase were also reconstructed using FDK method. Compared with the FDK results, the images from SMEIR method substantially improve the image quality with minimum artifacts. Conclusion: We demonstrate that it is viable to apply SMEIR method to reconstruct small animal 4D-CBCT images.

60 APPLIED LIFE SCIENCES↗

Detector positioning for the initial subcriticality level determination in accelerator-driven systems

Within the GUINEVERE project (Generation of Uninterrupted Intense Neutrons at the lead Venus Reactor) carried out at SCK-CEN in Mol, the continuous deuteron accelerator GENEPI-3C was coupled to the VENUS-F fast simulated lead-cooled reactor. Today the FREYA project (Fast Reactor Experiments for hYbrid Applications) is ongoing to study the neutronic behavior of this Accelerator Driven System (ADS) during different phases of operation. In particular the set-up of a monitoring system for the subcriticality of an ADS is envisaged to guarantee safe operation of the installation. The methodology for subcriticality monitoring in ADS takes into account the determination of the initial subcriticality level, the monitoring of reactivity variations, and interim cross-checking. At start-up, the Pulsed Neutron Source (PNS) technique is envisaged to determine the initial subcriticality level. Thanks to its reference critical state, the PNS technique can be validated on the VENUS-F core. A detector positioning methodology for the PNS technique is set up in this paper for the subcritical VENUS-F core, based on the reduction of higher harmonics in a static evaluation of the Sjoestrand area method. A first case study is provided on the VENUS-F core. This method can be generalised in order to create general rules for detector positions and types for full-scale ADS. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ICARUS at the Short-Baseline Neutrino Program: First Results

The ICARUS collaboration employed the 760-ton T600 detector in a successful three-year physics run at the underground LNGS laboratory. In 2021, ICARUS started its new operation at Fermilab, collecting a substantial amount of neutrino events from the Booster Neutrino Beam (BNB) and the neutrinos at the Main Injector (NuMI) beam off-axis. These were used to test the ICARUS event selection, reconstruction, and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022, moving then to data taking for neutrino oscillation physics, aiming at first to either confirm or refute the claim by the Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurements of neutrino cross sections in LAr with the NuMI beam and several Beyond Standard Model studies. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this work, preliminary results from the ICARUS data with the BNB and NuMI beams are presented, both in terms of the performance of all ICARUS subsystems and the capability to select and reconstruct neutrino events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resolving Standard and Nonstandard CP Violation Phases in Neutrino Oscillations

Neutrino oscillations can exhibit extra CP violation effects, beyond those expected from the standard Kobayashi-Maskawa phase delta, if non-standard neutrino interactions are at play. We show that it is possible to disentangle the two CP violating effects by measuring muon neutrino appearance using a near-far two detector setting in a neutrino factory experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗