At least 1,387 records · Page 77

Full Simulation of CMS for Run-3 and Phase-2

In this contribution we report the status of the CMS Geant4 simulation and the prospects for Run-3 and Phase-2. Firstly, we report about our experience during the start of Run-3 with Geant4 10.7.2, the common software package DD4hep for geometry description, and VecGeom runtime geometry library. In addition, FTFP_BERT_EMM Physics List and CMS configuration for tracking in magnetic field have been utilized. For the first time, for the Grid mass production of Monte-Carlo, this combination of components is used. Further simulation improvements are under development targeting Run-3 such as the switch to the new Geant4 11.1 in production, that provides several features important for the optimization of simulation, for example the new transportation process with built-in multiple scattering, neutron general process, custom tracking manager, G4HepEm sub-library, and others. We will present evaluation of various options, validation results, and the final choice of simulation configuration for 2023 production and beyond. The performance of the CMS full simulation for Run-2 and Run-3 will also be discussed. CMS development plan for the Phase-2 Geant4 based simulation is very ambitious, and it includes a new geometry description, physics, and simulation configurations. The progress on new detector descriptions and full simulation will be presented as well as the R&D in progress to reduce compute capacity needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

R and D of crystal scintillators from enriched isotopes for high sensitivity double β decay experiments

Experiments to search for neutrinoless double beta decay enters to a new phase when a sensitivity on the level of T{sub 1/2}∼10{sup 26}−10{sup 28} yr is required. Scintillating low temperature detectors possess important properties required for high-sensitivity double beta decay experiments: presence of elements of interest, high energy resolution and detection efficiency, low level of background thanks to excellent particle discrimination ability. High concentration of isotope of interest and as low as possible radioactive contamination are important requirements to crystal scintillators. Other crucial issues are maximal output of detectors and minimal loss of enriched materials. Prospects of several scintillation materials, enriched in isotopes promising for double beta decay experiments, are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data transmission by quantum matter wave modulation

Abstract Classical communication schemes exploiting wave modulation are the basis of our information era. Quantum information techniques with photons enable future secure data transfer in the dawn of decoding quantum computers. Here we demonstrate that also matter waves can be applied for secure data transfer. Our technique allows the transmission of a message by a quantum modulation of coherent electrons in a biprism interferometer. The data is encoded in the superposition state by a Wien filter introducing a longitudinal shift between separated matter wave packets. The transmission receiver is a delay line detector performing a dynamic contrast analysis of the fringe pattern. Our method relies on the Aharonov–Bohm effect but does not shift the phase. It is demonstrated that an eavesdropping attack will terminate the data transfer by disturbing the quantum state and introducing decoherence. Furthermore, we discuss the security limitations of the scheme due to the multi-particle aspect and propose the implementation of a key distribution protocol that can prevent active eavesdropping.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design improvements to cables and connectors in the Majorana Demonstrator

The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76 Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radio purity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. In conclusion, we will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.

42 ENGINEERING↗

Experimental strategies for imaging bioparticles with femtosecond hard X-ray pulses

This study explores the capabilities of the Coherent X-ray Imaging Instrument at the Linac Coherent Light Source to image small biological samples. The weak signal from small samples puts a significant demand on the experiment. Aerosolized Omono River virus particles of ~40 nm in diameter were injected into the submicrometre X-ray focus at a reduced pressure. Diffraction patterns were recorded on two area detectors. The statistical nature of the measurements from many individual particles provided information about the intensity profile of the X-ray beam, phase variations in the wavefront and the size distribution of the injected particles. The results point to a wider than expected size distribution (from ~35 to ~300 nm in diameter). This is likely to be owing to nonvolatile contaminants from larger droplets during aerosolization and droplet evaporation. The results suggest that the concentration of nonvolatile contaminants and the ratio between the volumes of the initial droplet and the sample particles is critical in such studies. The maximum beam intensity in the focus was found to be 1.9 × 10 12 photons per µm 2 per pulse. The full-width of the focus at half-maximum was estimated to be 500 nm (assuming 20% beamline transmission), and this width is larger than expected. Under these conditions, the diffraction signal from a sample-sized particle remained above the average background to a resolution of 4.25 nm. Finally, the results suggest that reducing the size of the initial droplets during aerosolization is necessary to bring small particles into the scope of detailed structural studies with X-ray lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ab initio structure determination of nanocrystals of organic pharmaceutical compounds by electron diffraction at room temperature using a Timepix quantum area direct electron detector

A specialized quantum area detector for electron diffraction studies makes it possible to solve the structure of small organic compound nanocrystals in non-cryo conditions by direct methods. Until recently, structure determination by transmission electron microscopy of beam-sensitive three-dimensional nanocrystals required electron diffraction tomography data collection at liquid-nitrogen temperature, in order to reduce radiation damage. Here it is shown that the novel Timepix detector combines a high dynamic range with a very high signal-to-noise ratio and single-electron sensitivity, enabling ab initio phasing of beam-sensitive organic compounds. Low-dose electron diffraction data (∼0.013 e{sup −} Å{sup −2} s{sup −1}) were collected at room temperature with the rotation method. It was ascertained that the data were of sufficient quality for structure solution using direct methods using software developed for X-ray crystallography (XDS, SHELX) and for electron crystallography (ADT3D/PETS, SIR2014)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NCSP IER 422 CED-3b Documentation

A Subcritical Copper-Reflected α-phase Plutonium (SCRαP) integral benchmark experiment has been designed and measured. In this experiment, multiplication is approximated using correlated neutron data from a detector system consisting of 3He tubes inside high density polyethylene (HDPE). Measurements were performed on various subcritical experimental configurations consisting of a weapons-grade plutonium sphere surrounded by different Cu thicknesses. In addition to the proposed base experimental configurations with Cu, additional configurations were performed with the plutonium ball nested in various thicknesses of interleaved HDPE spherical shells mixed in with the Cu shells. The HDPE is intended to provide fast neutron moderation and reflection, resulting in additional measurements with differing multiplication, spectra, and nuclear data sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Event Selections in the NOvA 2024 Analysis

The NuMI Off-axis $\nu_e$ Experiment (NOvA) is a long-baseline neutrino oscillation experiment that studies a neutrino beam produced by the Neutrinos at the Main Injector (NuMI) facility at Fermilab to constrain the PNFS mixing angles, the neutrino mass hierarchy, and the CP-violating phase $\delta_{CP}$. These parameters are extracted by comparing the spectra of muon neutrinos and electron neutrinos measured at the near and far detectors, using an extrapolation of the Near Detector spectra. Accurate event selection is critical to this process, as only interactions with well-reconstructed energies and interaction types should be included in the oscillation analysis to reduce systematic uncertainties. In this work, we describe the selection criteria used for muon and electron neutrinos in the Near and Far Detector. We demonstrate the effectiveness of the criteria by examining the efficiency and purity of the event selections as well as their impact on key variables used in the oscillation analysis.

Chen, Hanyi [Indiana U.]↗

Status of the DUNE experiment

The Deep Underground Neutrino Experiment aims at an unprecedentedly precise neutrino CPviolation phase measurement with a broad-band muon neutrino and antineutrino beam, a 1,300 km baseline, an order of 10skt fiducial mass detector with high particle identification efficiency and low external background.Additionally, the orders of systematic uncertainty should be constrained to 2% for the signal and5% for the background. This uncertainty constraint requires an unprecedented level of robustnessand redundancy in the near detector measurement. In this presentation, the near detector designand the far detector prototyping status are shown. The long-baseline sensitivity and differentphysics potentials are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Differential input preamplifier

Preamplifier chops and amplifies very low level output of thermopile infrared detectors that will be used to measure thermal energy flux of Jupiter and its departure from a blackbody spectrum. Output signal has negligible phase shift. AC signal is RC-coupled to input stage of other amplifiers.

Callaway, P. W.↗

Very high resolution radiometer

A primary sensor used in environmental and earth-resource observation, the Very High Resolution Radiometer (VHRR) was designed for use on the ITOS D series spacecraft. The VHRR provides a 0.47 mile resolution made possible with a mercury-cadmium-telluride detector cooled to approximately 105 K by a passive radiator cooler. The components of this system are described. The optical subsystem of the VHRR consists of a scanning mirror, a Dall-Kirkham telescope, a dichroic beam splitter, relay lenses, spectral filters, and an IR detector. Signal electronics amplify and condition the signals from the infrared and visible light detector. Sync generator electronics provides the necessary time signals. Scan-drive electronics is used for commutation of the motor winding, velocity, and phase control. A table lists the performance parameters of the VHRR.

Aronson, A. I.↗

Manned Mars mission solar physics: Solar energetic particle prediction and warning

There are specific risks to the crew of the manned Mars mission from energetic particles generated by solar activity. Therefore, mission planning must provide for solar monitoring and solar activity forecasts. The main need is to be able to anticipate the energetic particle events associated with some solar flares and, occasionally, with erupting filaments. A second need may be for forecasts of solar interference with radio communication between the manned Mars mission (during any of its three phases) and Earth. These two tasks are compatible with a small solar observatory that would be used during the transit and orbital phases of the mission. Images of the Sun would be made several times per hour and, together with a solar X-ray detector, used to monitor for the occurrence of solar activity. The data would also provide a basis for research studies of the interplanetary medium utilizing observations covering more of the surface of the Sun than just the portion facing Earth.

Suess, S. T.↗

IXPE - The Imaging X-Ray Polarimetry Explorer

The Imaging X-ray Polarimetry Explorer (IXPE) is a Small Explorer Mission that will be proposed in response to NASA's upcoming Announcement of Opportunity. IXPE will transform our understanding of the most energetic and exotic astrophysical objects, especially neutron stars and black holes, by measuring the linear polarization of astronomical objects as a function of energy, time and, where relevant, position. As the first dedicated polarimetry observatory IXPE will add a new dimension to the study of cosmic sources, enlarging the observational phase space and providing answers to fundamental questions. IXPE will feature x-ray optics fabricated at NASA/MSFC and gas pixel focal plane detectors provided by team members in Italy (INAF and INFN). This presentation will give an overview of the proposed IXPE mission, detailing the payload configuration, the expected sensitivity, and a typical observing program.

Ramsey, Brian↗

NO$\nu$A Data Acquisition Software System

NO{nu}A is an accelerator-based neutrino oscillation experiment which has a great potential to measure the last unknown mixing angle {theta}{sub 13}, the neutrino mass hierarchy, and the CP-violation phase in lepton sector with (1) 700 kW beam, (2) 14 mrad off the beam axis, (3) 810 km long baseline. The Near Detector on the Surface is fully functioning and taking both NuMI and Booster beam data. The far detector building achieved beneficial occupancy on April 13. This proceeding will focus on the DAQ software system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Snowmass2021 Cosmic Frontier White Paper: Future Gravitational-Wave Detector Facilities

The next generation of gravitational-wave observatories can explore a wide range of fundamental physics phenomena throughout the history of the universe. These phenomena include access to the universe's binary black hole population throughout cosmic time, to the universe's expansion history independent of the cosmic distance ladders, to stochastic gravitational-waves from early-universe phase transitions, to warped space-time in the strong-field and high-velocity limit, to the equation of state of nuclear matter at neutron star and post-merger densities, and to dark matter candidates through their interaction in extreme astrophysical environments or their interaction with the detector itself. We present the gravitational-wave detector concepts than can drive the future of gravitational-wave astrophysics. We summarize the status of the necessary technology, and the research needed to be able to build these observatories in the 2030s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel

Dark matter lighter than 10 GeV / c 2 encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These studies show that DarkSide-LowMass can achieve sensitivity to light dark matter down to the solar neutrino fog for GeV-scale masses and significant sensitivity down to 10 MeV / c 2 considering the Migdal effect or interactions with electrons. Requirements for optimizing the detector’s sensitivity are explored, as are potential sensitivity gains from modeling and mitigating spurious electron backgrounds that may dominate the signal at the lowest energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterisation of irradiated thin silicon sensors for the CMS phase II pixel upgrade

The high luminosity upgrade of the Large Hadron Collider, foreseen for 2026, necessitates the replacement of the CMS experiment’s silicon tracker. The innermost layer of the new pixel detector will be exposed to severe radiation, corresponding to a 1 MeV neutron equivalent fluence of up to $\Phi _{eq} = 2 \times 10^{16}$ cm$^{-2}$ , and an ionising dose of ${\approx } 5$ MGy after an integrated luminosity of 3000 fb$^{-1}$ . Thin, planar silicon sensors are good candidates for this application, since the degradation of the signal produced by traversing particles is less severe than for thicker devices. In this paper, the results obtained from the characterisation of 100 and 200 $\upmu $ m thick p-bulk pad diodes and strip sensors irradiated up to fluences of $\Phi _{eq} = 1.3 \times 10^{16}$ cm$^{-2}$ are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid state photomultiplier for astronomy, phase 2

Epitaxial layers with varying donor concentration profiles were grown on silicon substrate wafers using chemical vapor deposition (CVD) techniques, and solid state photomultiplier (SSPM) devices were fabricated from the wafers. Representative detectors were tested in a low background photon flux, low temperature environment to determine the device characteristics for comparison to NASA goals for astronomical applications. The SSPM temperatures varied between 6 and 11 K with background fluxes in the range from less than 5 x 10 to the 6th power to 10 to the 13th power photons/square cm per second at wavelengths of 3.2 and 20 cm. Measured parameters included quantum efficiency, dark count rate and bias current. Temperature for optimal performance is 10 K, the highest ever obtained for SSPMs. The devices exhibit a combination of the lowest dark current and highest quantum efficiency yet achieved. Experimental data were reduced, analyzed and used to generate recommendations for future studies. The background and present status of the microscopic theory of SSPM operation were reviewed and summarized. Present emphasis is on modeling of the avalanche process which is the basis for SSPM operation. Approaches to the solution of the Boltzmann transport equation are described and the treatment of electron scattering mechanisms is presented. The microscopic single-electron transport theory is ready to be implemented for large-scale computations.