Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PALLADIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Fabrication and Electromagnetic Characterization of Novel Self-Metallized Thin Films

Unique, self-metallized films were investigated for deployable reflector antenna applications at L-band. Polyamic acid resins or soluble polyimides were doped with metal complexes, cast into films, and thermally cured. Each resulting film had a metallic layer on one side, adhering unfailingly to the polymer. Metallization was successful for silver or palladium in 3,3',4,4'-benzophenonetetracarboxylic acid dianhydride (BTDA) and 4,4'- oxydianiline and for gold in BTDA and 2,2-bis[4-(4- aminophenoxy)phenyl]hexafluoropropane (4-BDAF) or the space durable polyimide, 2,2-bis(3,4-dicarboxyphenyl)- hexafluoropropane dianhydride and 4-BDAF (LaRCCP1). Reflectivity, transmissivity, and emissivity were determined, using an HP 8510 Vector Network Analyzer, to within 0.001 precision and accuracy. A custom-made test fixture/positioner, a thru-reflect-line calibration, and calculated reflection coefficients were used. The Ag film proved most suitable for further study, with 0.9957 reflectivity and 0.0042 emissivity. The Pd films were 0.89 reflective and 0.11 emissive; both Au films tested entirely transmissive. Transmission and scanning electron micrographs, S-parameters, and power coefficients are shown.

Mackenzie, Anne I.↗

Lunar and Planetary Science XXXVI, Part 7

Topics discussed include: Lunar Geologic Mapping: Preliminary Mapping of Copernicus Quad High-Resolution Topography of Layers in the Valles Marineris Via Thermoclinometry ; The Critical Importance of Data Reduction Calibrations in the Interpretability of S-type Asteroid Spectra; (sup 238)U-(sup 206)Pb Age and Uranium-Lead Isotope Systematics of Mare Basalt 10017; Morphological Investigations of Martian Spherules, Comparisons to Collected Terrestrial Counterparts; The Vapor Pressure of Palladium at Temperatures up to 1973K; Areas of Favorable Illumination at the Lunar Poles Calculated from Topography; An Indigenous Origin for the South Pole-Aitken Basin Thorium Anomaly; Ar-Ar Ages of Nakhlites Y000593, NWA998, and Nakhla and CRE Ages of NWA998; Experiments on the Acoustic Properties of Titan-like Atmospheres; Analysis of Downstream Transitions in Morphology and Structure of Lava Channels on Mars; Structure and Bonding of Carbon in Clays from CI Carbonaceous Chondrites; Comparison of Three Hydrogen Distributions at the Equator of Mars; An Impact Origin for the Foliation of Ordinary Chondrites; A New Micrometeorite Collection from Antarctica and Its Preliminary Characterization by Microobservation, Microanalysis and Magnetic Methods; Volcanic Plumes and Plume Deposits on Io; Results of the Alpha-Particle-X-Ray Spectrometer on Board of the Mars Exploration Rovers; Effects of Oceans on Atmospheric Loss During the Stage of Giant Impacts; and Identification of Predominant Ferric Signatures in Association to the Martian Sulfate Deposits

Source record↗

High-Temperature, Thin-Film Strain Gages Improved

Conventional resistance strain gage technology uses "bonded" strain gages. These foil or wire gages are bonded onto the surface of the test article with glue, ceramic cements, or flame-sprayed ceramics. These bonding agents can, in some instances, limit both the degree of strain transmission from the test structure to the gage and the maximum working temperature of the gage. Also, the bulky, bonded gage normally disrupts aerodynamic gas flow on the surface of the test structure because of its intrusive character. To respond to the urgent needs in aeronautic and aerospace research where stress and temperature gradients are high, aerodynamic effects need to be minimized, and higher operational temperatures are required, the NASA Lewis Research Center developed a thin film strain gage. This gage, a vacuum-deposited thin film formed directly on the surface of a test structure, operates at much higher temperatures than commercially available gages do and with minimal disruption of the aerodynamic flow. The gage uses an alloy, palladium-13 wt % chromium (hereafter, PdCr), which was developed by United Technologies Research Center under a NASA contract. PdCr is structurally stable and oxidation resistant up to at least 1100 C (2000 F); its temperature-induced resistance change is linear, repeatable, and not sensitive to the rates of heating and cooling. An early strain gage, which was made of 25-micrometer-diameter PdCr wire and demonstrated to be useable to 800 C, won an R&D 100 award in 1991. By further improving the purity of the material and by developing gage fabrication techniques that use sputter-deposition, photolithography patterning, and chemical etching, we have made an 8- to 10-m PdCr thin-film strain gage that can measure dynamic and static strain to at least 1100 C. For static strain measurements, a 5-m-thick Pt element serves as a temperature compensator to further minimize the temperature effect of the gage. These thin-film gages provide the advantage of minimally intrusive surface strain measurements and give highly repeatable readings with low drift at temperatures from ambient to 1100 C. This is a 300 C advance in operating temperature over the PdCr wire gage and a 500 C advance over commercially available gages made of other materials.

Source record↗

Hydrogen Sensors Demonstrated on the Shuttle

Microelectromechanical-systems- (MEMS-) based hydrogen sensor technology developed by the NASA Glenn Research Center at Lewis Field and Case Western Reserve University was demonstrated on shuttle missions STS-95 (Senator Glenn s mission) and STS-96. These smart sensors, commercialized by Makel Engineering Inc., were part of an "Integrated Vehicle Health Monitoring HEDS Technology Demonstration" series conducted at the NASA Kennedy Space Center. The experiments were designed to demonstrate the effect of technological upgrades on shuttle performance. The hydrogen sensors were micro-fabricated for minimal size, weight, and power consumption. A temperature detector and heater were included on the sensor for temperature control. Two palladium chrome (PdCr) hydrogen detection devices were included in each sensor package: a Schottky diode for low concentrations and a resistor for high concentrations. These sensor designs allow operation in inert environments. "Smart" electronics developed by Makel Engineering were integrated with the sensors to control the sensor temperature and process the output of the various sensors. This complete hydrogen detection system (two sensors on a chip with smart electronics) flew on STS-95 (launched October 1998) and STS-96 (launched May 1999). It was installed in the aft compartment of the shuttle and used to monitor the hydrogen concentration in that region. Up to this time, a mass spectrometer had monitored the hydrogen concentration in the aft compartment before launch, and "grab" bottles had been used after launch. The inside of these bottles is at vacuum. During flight, the grab bottles are pyrotechnically opened for a brief period, and the gas in the aft compartment is captured in the bottle. Several of these bottles are opened at different times during takeoff, and their contents are used to determine the time profile of the gases in the aft chamber. However, this information is not available until after the flight. On the launch pad, results from the new sensor technology paralleled the responses of the mass spectrometer with, in some cases, a quicker response time. In flight, data from the new sensors agreed with those derived from analyzing the contents of the grab bottles. Moreover, this microsensor can monitor the aft compartment continuously and, in principle, could monitor the health of the vehicle in real time during flight.

Hunter, Gary W.↗

Brazing of Stainless Steels to Yttria Stabilized Zirconia (YSZ) Using Silver -Base Brazes

Three silver-base brazes containing either noble metal palladium (Palcusil-10 and Palcusil-15) or active metal titanium (Ticusil) were evaluated for high-temperature oxidation resistance, and their effectiveness in joining yttria stabilized zirconia (YSZ) to a corrosion-resistant ferritic stainless steel. Thermogravimetric analysis (TGA), and optical- and scanning electron microscopy (SEM) coupled with energy dispersive spectrometry (EDS) were used to evaluate the braze oxidation behavior and the structure and chemistry of the YSZ/braze/steel joints. The effect of the braze type and processing conditions on the interfacial microstructure and composition of the joint regions is discussed with reference to the chemical changes that occur at the interface. It was found that chemical interdiffusion of the constituents of YSZ, steel and the brazes led to compositional changes and/or interface reconstruction, and metallurgically sound joints.

Singh, Mrityunjay↗

Processing of Ni30Pt20Ti50 High-Temperature Shape-Memory Alloy Into Thin Rod Demonstrated

High-temperature shape-memory alloys (HTSMAs) based on nickel-titanium (NiTi) with significant ternary additions of palladium (Pd), platinum (Pt), gold (Au), or hafnium (Hf) have been identified as potential high-temperature actuator materials for use up to 500 C. These materials provide an enabling technology for the development of "smart structures" used to control the noise, emissions, or efficiency of gas turbine engines. The demand for these high-temperature versions of conventional shape-memory alloys also has been growing in the automotive, process control, and energy industries. However these materials, including the NiPtTi alloys being developed at the NASA Glenn Research Center, will never find widespread acceptance unless they can be readily processed into useable forms.

Noebe, Ronald D.↗

Chemical Characterization and Thermal Stressing Studies of Perfluorohexane Fluids for Space-Based Applications

Perfluorohexane (PFH), C6F14, is a perfluorocarbon fluid. Several PFH fluids with different isomer concentrations were evaluated for use in an upcoming NASA space experiment. Samples tested included two commercially obtained high-purity n-perfluorohexane (n-PFH) fluids and a technical grade mixture of C6F14 branched and linear isomers (FC-72(TradeMark)). These fluids were evaluated for exact chemical composition, impurity purity and high temperature degradation behavior (pyrolysis). Our investigation involved simulated thermal stressing studies of PFH fluids under conditions likely to occur in the event of an atmospheric breach within the International Space Station (ISS) and subsequent exposure of the vapors to the high temperature and catalyst present in its Trace Contaminant Control Subsystem (TCCS). Exposure to temperatures in the temperature range of 200-450 C in an inert or oxidizing atmosphere, with and without the presence of catalyst was investigated. The most aggressive conditions studied were exposure of PFH vapors to 450 C in air and in the presence of TCCS (palladium) catalyst. Gas chromatography-mass spectrometry (GC-MS) and gas chromatography (GC) analyses were conducted on the perfluorohexane samples before and after pyrolysis. The FC-72 and n-PFH samples showed no significant degradation following pyrolysis even under the most aggressive study conditions. Some trace level impurities associated with the PFH samples such as linear perfluorocarbon monohydrides or monoiodides were destroyed by pyrolysis at the upper limit. Other trace level impurities such as olefinic or cycloolefinic perfluorocarbons were converted into oxidation products by pyrolysis. The purity of PFH following pyrolysis actually increased slightly as a consequence since these trace contaminants were effectively scrubbed from the samples. However, since the initial concentrations of the thermally-impacted impurities were so low, the net effect was trivial. A potential byproduct of exposure of perfluorohexane fluids to high temperatures is the production of perfluoroisobutene (PFiB), which is extremely toxic. An ultra-high sensitivity PFiB-specific analysis based on GC-MS with negative ion chemical ionization (NICI) detection was used to evaluate the samples following thermal stressing. The perfluorohexanes examined here under conditions reflective of the ISS TCCS environment showed no signs of PFiB production with an analytical detection limit of 10 part per billion (ppb v/v).

Arnold, William A.↗

Nanowire sensors and arrays for chemical/biomolecule detection

We report electrochemical growth of single nanowire based sensors using e-beam patterned electrolyte channels, potentially enabling the controlled fabrication of individually addressable high density arrays. The electrodeposition technique results in nanowires with controlled dimensions, positions, alignments, and chemical compositions. Using this technique, we have fabricated single palladium nanowires with diameters ranging between 75 nm and 300 nm and conducting polymer nanowires (polypyrrole and polyaniline) with diameters between 100 nm and 200 nm. Using these single nanowires, we have successfully demonstrated gas sensing with Pd nanowires and pH sensing with polypirrole nanowires.

sensor array↗

Developing Multilayer Thin Film Strain Sensors With High Thermal Stability

A multilayer thin film strain sensor for large temperature range use is under development using a reactively-sputtered process. The sensor is capable of being fabricated in fine line widths utilizing the sacrificial-layer lift-off process that is used for micro-fabricated noble-metal sensors. Tantalum nitride films were optimized using reactive sputtering with an unbalanced magnetron source. A first approximation model of multilayer resistance and temperature coefficient of resistance was used to set the film thicknesses in the multilayer film sensor. Two multifunctional sensors were fabricated using multilayered films of tantalum nitride and palladium chromium, and tested for low temperature resistivity, TCR and strain response. The low temperature coefficient of resistance of the films will result in improved stability in thin film sensors for low to high temperature use.

Wrbanek, John D.↗

Calculation of Free-Atom Fractions in Hydrocarbon-Fueled Rocket Engine Plume

Free atom fractions (Beta) of nine elements are calculated in the exhaust plume of CH4- oxygen and RP-1-oxygen fueled rocket engines using free energy minimization method. The Chemical Equilibrium and Applications (CEA) computer program developed by the Glenn Research Center, NASA is used for this purpose. Data on variation of Beta in both fuels as a function of temperature (1600 K - 3100 K) and oxygen to fuel ratios (1.75 to 2.25 by weight) is presented in both tabular and graphical forms. Recommendation is made for the Beta value for a tenth element, Palladium. The CEA computer code was also run to compare with experimentally determined Beta values reported in literature for some of these elements. A reasonable agreement, within a factor of three, between the calculated and reported values is observed. Values reported in this work will be used as a first approximation for pilot rocket engine testing studies at the Stennis Space Center for at least six elements Al, Ca, Cr, Cu, Fe and Ni - until experimental values are generated. The current estimates will be improved when more complete thermodynamic data on the remaining four elements Ag, Co, Mn and Pd are added to the database. A critique of the CEA code is also included.

Verma, Satyajit↗

Electrochemically Grown Single Nanowire Sensors

We report a fabrication technique that is potentially capable of producing arrays of individually addressable nanowire sensors with controlled dimensions, positions, alignments, and chemical compositions. The concept has been demonstrated with electrodeposition of palladium wires with 75 nm to 350 nm widths. We have also fabricated single and double conducting polymer nanowires (polyaniline and polypyrrole) with 100nm and 200nm widths using electrochemical direct growth. Using single Pd nanowires, we have also demonstrated hydrogen sensing. It is envisioned that these are the first steps towards nanowire sensor arrays capable of simultaneously detecting multiple chemical species.

conducting polymer nanowires↗

Electronically conducting polymers with silver grains

The present invention provides electronically conducting polymer films formed from photosensitive formulations of pyrrole and an electron acceptor that have been selectively exposed to UV light, laser light, or electron beams. The formulations may include photoinitiators, flexibilizers, solvents and the like. These solutions can be used in applications including printed circuit boards and through-hole plating and enable direct metallization processes on non-conducting substrates. After forming the conductive polymer patterns, a printed wiring board can be formed by sensitizing the polymer with palladium and electrolytically depositing copper.

Murphy, Oliver J.↗

High temperature thrust chamber for spacecraft

A high temperature thrust chamber for spacecraft (20) is provided herein. The high temperature thrust chamber comprises a hollow body member (12) having an outer surface and an internal surface (16) defining the high temperature chamber (10). The body member (12) is made substantially of rhenium. An alloy (18) consisting of iridium and at least alloying metal selected of the group consisting of rhodium, platinum and palladium is deposited on at least a portion of the internal surface (16) of the body member (12). The iridium and the alloying metal are electrodeposited onto the body member (12). A HIP cycle is performed upon the body member (12) to cause the coating of iridium and the alloying metal to form the alloy (18) which protects the body member (12) from oxidation.

Chazen, Melvin L.↗

Imide oligomers endcapped with phenylethynyl phthalic anhydrides and polymers therefrom

Controlled molecular weight phenylethynyl terminated imide oligomers (PETIs) have been prepared by the cyclodehydration of precursor phenylethynyl terminated amic acid oligomers. Amino terminated amic acid oligomers are prepared from the reaction of dianhydride(s) with an excess of diamine(s) and subsequently endcapped with phenylethynyl phthalic anhydride(s) (PEPA). The polymerizations are carried out in polar aprotic solvents such as N-methyl-2-pyrrolidinone or N,N-dimethylacetamide under nitrogen at room temperature. The amic acid oligomers are subsequently cyclodehydrated either thermally or chemically to the corresponding imide oligomers. Direct preparation of PETIs from the reaction of dianhydride(s) with an excess of diamine(s) and endcapped with phenylethynyl phthalic anhydride(s) has been performed in m-cresol. Phenylethynyl phthalic anhydrides are synthesized by the palladium catalyzed reaction of phenylacetylene with bromo substituted phthalic anhydrides in triethylamine. These new materials exhibit excellent properties and are potentially useful as adhesives, coatings, films, moldings and composite matrices.

Hergenrother, Paul M.↗

Method of forming electronically conducting polymers on conducting and nonconducting substrates

The present invention provides electronically conducting polymer films formed from photosensitive formulations of pyrrole and an electron acceptor that have been selectively exposed to UV light, laser light, or electron beams. The formulations may include photoinitiators, flexibilizers, solvents and the like. These solutions can be used in applications including printed circuit boards and through-hole plating and enable direct metallization processes on non-conducting substrates. After forming the conductive polymer patterns, a printed wiring board can be formed by sensitizing the polymer with palladium and electrolytically depositing copper.

Murphy, Oliver J.↗

Method of synthesizing metal doped diamond-like carbon films

A method of synthesizing metal doped carbon films by placing a substrate in a chamber with a selected amount of a metalorganic compound. An electron cyclotron resonance is applied to the chamber in order to vaporize the metalorganic compound. The resonance is applied to the chamber until a metal doped carbon film is formed. The metalorganic compound is preferably selected from the group consisting of an organic salt of ruthenium, palladium, gold or platinum.

Ueno, Mayumi↗

PdCr Based High Temperature Static Strain Gage

The program at NASA Lewis Research Center to develop a high temperature static strain gage system for the hypersonic vehicle and turbine engine research has emphasized a palladium- 13wt%chromium (PdCr) alloy. Gages made from this alloy are being developed in both fine wire and thin film form. The wire gage system had platinum wire as a temperature compensator and was coated with a special alumina and zirconia mixture overcoat. This PdCr compensated wire gage responded linearly to the imposed strain to at least i000 microstrain. The strain sensitivity of the gage did not vary much with temperature. The apparent strain of this compensated gage was significantly lower than that of the other gages. It varied within 300 microstrain from room temperature to 800 deg. C with a reproducibility within 50 microstrain between thermal cycles to 800 deg. C. This is a significant advance over the 400 deg. C barrier of previous techniques for resistance static strain gages. The sputtered thin film PdCr strain gage, whose size was 8x8 mm and 10 micron thick, has demonstrated the possibility of extending the use of the PdCr strain gage to a temperature of approximately 1000 deg. C.

Lei, Jih-Fen↗