Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Online Primal-Dual Methods With Measurement Feedback for Time-Varying Convex Optimization

This paper addresses the design and analysis of feedback-based online algorithms to control systems or networked systems based on performance objectives and engineering constraints that may evolve over time. The emerging timevarying convex optimization formalism is leveraged to model optimal operational trajectories of the systems, as well as explicit local and network-level operational constraints. Departing from existing batch and feed-forward optimization approaches, the design of the algorithms capitalizes on an online implementation of primal-dual projected-gradient methods; the gradient steps are, however, suitably modified to accommodate feedback from the system in the form of measurements - hence, the term 'online optimization with feedback.' By virtue of this approach, the resultant algorithms can cope with model mismatches in the algebraic representation of the system states and outputs, they avoid pervasive measurements of exogenous inputs, and they naturally lend themselves to a distributed implementation. Under suitable assumptions, analytical convergence claims are established in terms of dynamic regret. Furthermore, when the synthesis of the feedback-based online algorithms is based on a regularized Lagrangian function, Q-linear convergence to solutions of the time-varying optimization problem is shown.

97 MATHEMATICS AND COMPUTING↗

Multi-objective optimization of root phenotypes for nutrient capture using evolutionary algorithms

Root phenotypes are avenues to the development of crop cultivars with improved nutrient capture, which is an important goal for global agriculture. The fitness landscape of root phenotypes is highly complex and multidimensional. It is difficult to predict which combinations of traits (phene states) will create the best performing integrated phenotypes in various environments. Brute force methods to map the fitness landscape by simulating millions of phenotypes in multiple environments are computationally challenging. Evolutionary optimization algorithms may provide more efficient avenues to explore high dimensional domains such as the root phenotypic space. We coupled the three-dimensional functional–structural plant model, SimRoot, to the Borg Multi-Objective Evolutionary Algorithm (MOEA) and the evolutionary search over several generations facilitated the identification of optimal root phenotypes balancing trade-offs across nutrient uptake, biomass accumulation, and root carbon costs in environments varying in nutrient availability. Our results show that several combinations of root phenes generate optimal integrated phenotypes where performance in one objective comes at the cost of reduced performance in one or more of the remaining objectives, and such combinations differed for mobile and non-mobile nutrients and for maize (a monocot) and bean (a dicot). Functional–structural plant models can be used with multi-objective optimization to identify optimal root phenotypes under various environments, including future climate scenarios, which will be useful in developing the more resilient, efficient crops urgently needed in global agriculture.

59 BASIC BIOLOGICAL SCIENCES↗

Pareto Optimal and Dual-Objective Geometric and Structural Design of an Underwater Kite for Closed-Loop Flight Performance

This paper presents the formulation and results for a control-aware optimization of the combined geometric and structural design of an energy-harvesting underwater kite. Because kite-based energy-harvesting systems, both airborne and underwater, possess strong coupling between closed-loop flight control, geometric design, and structural design, consideration of all three facets of the design within a single codesign framework is highly desirable. However, while prior literature has addressed one or two attributes of the design at a time, this work constitutes the first comprehensive effort aimed at addressing all three. In particular, focusing on the goals of power maximization and mass minimization, we present a codesign formulation that fuses a geometric optimization tool, structural optimization tool, and closed-loop flight efficiency map. The resulting integrated codesign tool is used to address two mathematical optimization formulations that exhibit subtle differences: a Pareto optimal formulation and a dual-objective formulation that focuses on a weighted power-to-mass ratio as the techno-economic metric of merit. Further, based on the resulting geometric and structural designs, using a mediumfidelity closed-loop simulation tool, the proposed formulation is shown to achieve more than three times the powerto-mass ratio of a previously published, unoptimized benchmark design.

42 ENGINEERING↗

Westinghouse waste simulation and optimization software tool

Applications for dynamic simulation can be found in virtually all areas of process engineering. The tangible benefits of using dynamic simulation can be seen in tighter design, smoother start-ups and optimized operation. Thus, proper implementation of dynamic simulation can deliver substantial benefits. These benefits are typically derived from improved process understanding. Simulation gives confidence in evidence based decisions and enables users to try out lots of 'what if' scenarios until one is sure that a decision is the right one. In radioactive waste treatment tasks different kinds of waste with different volumes and properties have to be treated, e.g. from NPP operation or D and D activities. Finding a commercially and technically optimized waste treatment concept is a time consuming and difficult task. The Westinghouse Waste Simulation and Optimization Software Tool will enable the user to quickly generate reliable simulation models of various process applications based on equipment modules. These modules can be built with ease and be integrated into the simulation model. This capability ensures that this tool is applicable to typical waste treatment tasks. The identified waste streams and the selected treatment methods are the basis of the simulation and optimization software. After implementing suitable equipment data into the model, process requirements and waste treatment data are fed into the simulation to finally generate primary simulation results. A sensitivity analysis of automated optimization features of the software generates the lowest possible lifecycle cost for the simulated waste stream. In combination with proven waste management equipments and integrated waste management solutions, this tool provides reliable qualitative results that lead to an effective planning and minimizes the total project planning risk of any waste management activity. It is thus the ideal tool for designing a waste treatment facility in an optimum manner, taking account of the detailed waste stream and specific requirements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimal band selection for target detection with a LWIR multispectral imager

Multispectral imaging can offer many benefits in cost, complexity, resolution, size, weight, and power, relative to hyperspectral imaging. When designing a multispectral system, spectral bandpasses can be selected using optimization algorithms configured to maximally separate target detection scores between target and background regions. A hyperspectral image (HSI) can serve as the source of data from which band groupings can be tested for optimality. The output of an adaptive cosine estimator target detection algorithm is used in an objective function. Three optimization algorithms are compared: particle swarm, dual annealing, and differential evolution. A global optimum is also found using a brute force approach on the Livermore Computing Syrah supercomputer. Three materials are investigated: calcite, gypsum, and limestone. This is done for 3-, 4-, and 5-band systems. The data originate from a longwave infrared HSI of a material display board. The optimization algorithms were run 30 times for every scenario. Performance statistics (maximum, minimum, mean, standard deviation, and median) based on the separation values are given. Additional characterization was performed using receiver operator characteristic (ROC) curves and the area under the ROC curve. While good performance was obtained for the three optimization algorithms, the dual annealing algorithm produced the highest and most consistent detection separation scores on average.

47 OTHER INSTRUMENTATION↗

A technique optimization protocol and the potential for dose reduction in digital mammography

Digital mammography requires revisiting techniques that have been optimized for prior screen/film mammography systems. The objective of the study was to determine optimized radiographic technique for a digital mammography system and demonstrate the potential for dose reduction in comparison to the clinically established techniques based on screen- film. An objective figure of merit (FOM) was employed to evaluate a direct-conversion amorphous selenium (a-Se) FFDM system (Siemens Mammomat Novation{sup DR}, Siemens AG Medical Solutions, Erlangen, Germany) and was derived from the quotient of the squared signal-difference-to-noise ratio to mean glandular dose, for various combinations of technique factors and breast phantom configurations including kilovoltage settings (23-35 kVp), target/filter combinations (Mo-Mo and W-Rh), breast-equivalent plastic in various thicknesses (2-8 cm) and densities (100% adipose, 50% adipose/50% glandular, and 100% glandular), and simulated mass and calcification lesions. When using a W-Rh spectrum, the optimized FOM results for the simulated mass and calcification lesions showed highly consistent trends with kVp for each combination of breast density and thickness. The optimized kVp ranged from 26 kVp for 2 cm 100% adipose breasts to 30 kVp for 8 cm 100% glandular breasts. The use of the optimized W-Rh technique compared to standard Mo-Mo techniques provided dose savings ranging from 9% for 2 cm thick, 100% adipose breasts, to 63% for 6 cm thick, 100% glandular breasts, and for breasts with a 50% adipose/50% glandular composition, from 12% for 2 cm thick breasts up to 57% for 8 cm thick breasts.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intensity modulated proton therapy treatment planning using single-field optimization: The impact of monitor unit constraints on plan quality

Purpose: To investigate the effect of monitor unit (MU) constraints on the dose distribution created by intensity modulated proton therapy (IMPT) treatment planning using single-field optimization (SFO). Methods: Ninety-four energies between 72.5 and 221.8 MeV are available for scanning beam IMPT delivery at our institution. The minimum and maximum MUs for delivering each pencil beam (spot) are 0.005 and 0.04, respectively. These MU constraints are not considered during optimization by the treatment planning system; spots are converted to deliverable MUs during postprocessing. Treatment plans for delivering uniform doses to rectangular volumes with and without MU constraints were generated for different target doses, spot spacings, spread-out Bragg peak (SOBP) widths, and ranges in a homogeneous phantom. Four prostate cancer patients were planned with and without MU constraints using different spot spacings. Rounding errors were analyzed using an in-house software tool. Results: From the phantom study, the authors have found that both the number of spots that have rounding errors and the magnitude of the distortion of the dose distribution from the ideally optimized distribution increases as the field dose, spot spacing, and range decrease and as the SOBP width increases. From our study of patient plans, it is clear that as the spot spacing decreases the rounding error increases, and the dose coverage of the target volume becomes unacceptable for very small spot spacings. Conclusions: Constraints on deliverable MU for each spot could create a significant distortion from the ideally optimized dose distributions for IMPT fields using SFO. To eliminate this problem, the treatment planning system should incorporate the MU constraints in the optimization process and the delivery system should reliably delivery smaller minimum MUs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method for optimizing LINAC treatment geometry for volumetric modulated arc therapy of multiple brain metastases

Purpose: Volumetric modulated arc therapy (VMAT) is a rotational delivery technique in which MLC shapes, dose rate, and gantry rotation speed are optimized to produce conformal dose distributions. The aim of this work is to develop a beam projection method for deriving the optimal table and collimator angles for multilesion treatment planning. Methods: The method consists of four steps. The first step is to define the vector of beam-eye-view (BEV)-Y-axis in the treatment planning CT coordinates. The second step is to project each target onto the BEV-Y-axis vector. In the third step, the best table and collimator angle are found with a brute-force optimization technique that minimizes MLC leaf sharing between lesions. The fourth step is to generate an optimized VMAT plan with appropriate table/collimator angles and evaluate the plan quality. Results: The authors tested the method on three example cases with targets of various locations in the brain and sizes ranging from 1.18 to 17.86 cm{sup 3}. Applying the optimized geometric parameter to generate VMAT plan, a reduction of the 12 Gy volume was more than 6.1% for all cases; the plan homogeneity (D{sub 2%}-D{sub 95%}) was improved from 5.88{+-}1.21 to 5.21{+-}0.93 Gy vs a VMAT plan with the manufacturer recommended table and collimator angles. Conclusions: The authors conclude that the use of the projection method minimizes the sharing of MLC leaves between lesions and improves the plan quality for multilesion VMAT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biological-based optimization and volumetric modulated arc therapy delivery for stereotactic body radiation therapy

Purpose: To describe biological-based optimization and Monte Carlo (MC) dose calculation-based treatment planning for volumetric modulated arc therapy (VMAT) delivery of stereotactic body radiation therapy (SBRT) in lung, liver, and prostate patients. Methods: Optimization strategies and VMAT planning parameters using a biological-based optimization MC planning system were analyzed for 24 SBRT patients. Patients received a median dose of 45 Gy [range, 34-54 Gy] for lung tumors in 1-5 fxs and a median dose of 52 Gy [range, 48-60 Gy] for liver tumors in 3-6 fxs. Prostate patients received a fractional dose of 10 Gy in 5 fxs. Biological-cost functions were used for plan optimization, and its dosimetric quality was evaluated using the conformity index (CI), the conformation number (CN), the ratio of the volume receiving 50% of the prescription dose over the planning target volume (Rx/PTV50). The quality and efficiency of the delivery were assessed according to measured quality assurance (QA) passing rates and delivery times. For each disease site, one patient was replanned using physical cost function and compared to the corresponding biological plan. Results: Median CI, CN, and Rx/PTV50 for all 24 patients were 1.13 (1.02-1.28), 0.79 (0.70-0.88), and 5.3 (3.1-10.8), respectively. The median delivery rate for all patients was 410 MU/min with a maximum possible rate of 480 MU/min (85%). Median QA passing rate was 96.7%, and it did not significantly vary with the tumor site. Conclusions: VMAT delivery of SBRT plans optimized using biological-motivated cost-functions result in highly conformal dose distributions. Plans offer shorter treatment-time benefits and provide efficient dose delivery without compromising the plan conformity for tumors in the prostate, lung, and liver, thereby improving patient comfort and clinical throughput. The short delivery times minimize the risk of patient setup and intrafraction motion errors often associated with long SBRT treatment delivery times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving IMRT-plan quality with MLC leaf position refinement post plan optimization

Purpose: In intensity-modulated radiation therapy (IMRT) planning, reducing the pencil-beam size may lead to a significant improvement in dose conformity, but also increase the time needed for the dose calculation and plan optimization. The authors develop and evaluate a postoptimization refinement (POpR) method, which makes fine adjustments to the multileaf collimator (MLC) leaf positions after plan optimization, enhancing the spatial precision and improving the plan quality without a significant impact on the computational burden. Methods: The authors' POpR method is implemented using a commercial treatment planning system based on direct aperture optimization. After an IMRT plan is optimized using pencil beams with regular pencil-beam step size, a greedy search is conducted by looping through all of the involved MLC leaves to see if moving the MLC leaf in or out by half of a pencil-beam step size will improve the objective function value. The half-sized pencil beams, which are used for updating dose distribution in the greedy search, are derived from the existing full-sized pencil beams without need for further pencil-beam dose calculations. A benchmark phantom case and a head-and-neck (HN) case are studied for testing the authors' POpR method. Results: Using a benchmark phantom and a HN case, the authors have verified that their POpR method can be an efficient technique in the IMRT planning process. Effectiveness of POpR is confirmed by noting significant improvements in objective function values. Dosimetric benefits of POpR are comparable to those of using a finer pencil-beam size from the optimization start, but with far less computation and time. Conclusions: The POpR is a feasible and practical method to significantly improve IMRT-plan quality without compromising the planning efficiency.

60 APPLIED LIFE SCIENCES↗

A linear programming model for optimizing HDR brachytherapy dose distributions with respect to mean dose in the DVH-tail

Purpose: Recent research has shown that the optimization model hitherto used in high-dose-rate (HDR) brachytherapy corresponds weakly to the dosimetric indices used to evaluate the quality of a dose distribution. Although alternative models that explicitly include such dosimetric indices have been presented, the inclusion of the dosimetric indices explicitly yields intractable models. The purpose of this paper is to develop a model for optimizing dosimetric indices that is easier to solve than those proposed earlier.Methods: In this paper, the authors present an alternative approach for optimizing dose distributions for HDR brachytherapy where dosimetric indices are taken into account through surrogates based on the conditional value-at-risk concept. This yields a linear optimization model that is easy to solve, and has the advantage that the constraints are easy to interpret and modify to obtain satisfactory dose distributions.Results: The authors show by experimental comparisons, carried out retrospectively for a set of prostate cancer patients, that their proposed model corresponds well with constraining dosimetric indices. All modifications of the parameters in the authors' model yield the expected result. The dose distributions generated are also comparable to those generated by the standard model with respect to the dosimetric indices that are used for evaluating quality.Conclusions: The authors' new model is a viable surrogate to optimizing dosimetric indices and quickly and easily yields high quality dose distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose optimization in cardiac x-ray imaging

Purpose: The aim of this research was to optimize x-ray image quality to dose ratios in the cardiac catheterization laboratory. This study examined independently the effects of peak x-ray tube voltage (kVp), copper (Cu), and gadolinium (Gd) x-ray beam filtration on the image quality to radiation dose balance for adult patient sizes.Methods: Image sequences of polymethyl methacrylate (PMMA) phantoms representing two adult patient sizes were captured using a modern flat panel detector based x-ray imaging system. Tin and copper test details were used to simulate iodine-based contrast medium and stents/guide wires respectively, which are used in clinical procedures. Noise measurement for a flat field image and test detail contrast were used to calculate the contrast to noise ratio (CNR). Entrance surface dose (ESD) and effective dose measurements were obtained to calculate the figure of merit (FOM), CNR{sup 2}/dose. This FOM determined the dose efficiency of x-ray spectra investigated. Images were captured with 0.0, 0.1, 0.25, 0.4, and 0.9 mm Cu filtration and with a range of gadolinium oxysulphide (Gd{sub 2}O{sub 2}S) filtration.Results: Optimum x-ray spectra were the same for the tin and copper test details. Lower peak tube voltages were generally favored. For the 20 cm phantom, using 2 Lanex Fast Back Gd{sub 2}O{sub 2}S screens as x-ray filtration at 65 kVp provided the highest FOM considering ESD and effective dose. Considering ESD, this FOM was only marginally larger than that from using 0.4 mm Cu at 65 kVp. For the 30 cm phantom, using 0.25 mm copper filtration at 80 kVp was most optimal; considering effective dose the FOM was highest with no filtration at 65 kVp.Conclusions: These settings, adjusted for x-ray tube loading limits and clinically acceptable image quality, should provide a useful option for optimizing patient dose to image quality in cardiac x-ray imaging. The same optimal x-ray beam spectra were found for both the tin and copper details, suggesting that iodine contrast based imaging and visualization of interventional devices could potentially be optimized for dose using similar x-ray beam spectra.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multicriteria optimization of the spatial dose distribution

Purpose: Treatment planning for radiation therapy involves trade-offs with respect to different clinical goals. Typically, the dose distribution is evaluated based on few statistics and dose–volume histograms. Particularly for stereotactic treatments, the spatial dose distribution represents further criteria, e.g., when considering the gradient between subregions of volumes of interest. The authors have studied how to consider the spatial dose distribution using a multicriteria optimization approach.Methods: The authors have extended a stepwise multicriteria optimization approach to include criteria with respect to the local dose distribution. Based on a three-dimensional visualization of the dose the authors use a software tool allowing interaction with the dose distribution to map objectives with respect to its shape to a constrained optimization problem. Similarly, conflicting criteria are highlighted and the planner decides if and where to relax the shape of the dose distribution.Results: To demonstrate the potential of spatial multicriteria optimization, the tool was applied to a prostate and meningioma case. For the prostate case, local sparing of the rectal wall and shaping of a boost volume are achieved through local relaxations and while maintaining the remaining dose distribution. For the meningioma, target coverage is improved by compromising low dose conformality toward noncritical structures. A comparison of dose–volume histograms illustrates the importance of spatial information for achieving the trade-offs.Conclusions: The results show that it is possible to consider the location of conflicting criteria during treatment planning. Particularly, it is possible to conserve already achieved goals with respect to the dose distribution, to visualize potential trade-offs, and to relax constraints locally. Hence, the proposed approach facilitates a systematic exploration of the optimal shape of the dose distribution.

61 RADIATION PROTECTION AND DOSIMETRY↗

A critical evaluation of worst case optimization methods for robust intensity-modulated proton therapy planning

Purpose: To critically evaluate and compare three worst case optimization methods that have been previously employed to generate intensity-modulated proton therapy treatment plans that are robust against systematic errors. The goal of the evaluation is to identify circumstances when the methods behave differently and to describe the mechanism behind the differences when they occur. Methods: The worst case methods optimize plans to perform as well as possible under the worst case scenario that can physically occur (composite worst case), the combination of the worst case scenarios for each objective constituent considered independently (objectivewise worst case), and the combination of the worst case scenarios for each voxel considered independently (voxelwise worst case). These three methods were assessed with respect to treatment planning for prostate under systematic setup uncertainty. An equivalence with probabilistic optimization was used to identify the scenarios that determine the outcome of the optimization. Results: If the conflict between target coverage and normal tissue sparing is small and no dose-volume histogram (DVH) constraints are present, then all three methods yield robust plans. Otherwise, they all have their shortcomings: Composite worst case led to unnecessarily low plan quality in boundary scenarios that were less difficult than the worst case ones. Objectivewise worst case generally led to nonrobust plans. Voxelwise worst case led to overly conservative plans with respect to DVH constraints, which resulted in excessive dose to normal tissue, and less sharp dose fall-off than the other two methods. Conclusions: The three worst case methods have clearly different behaviors. These behaviors can be understood from which scenarios that are active in the optimization. No particular method is superior to the others under all circumstances: composite worst case is suitable if the conflicts are not very severe or there are DVH constraints whereas voxelwise worst case is advantageous if there are severe conflicts but no DVH constraints. The advantages of composite and voxelwise worst case outweigh those of objectivewise worst case.

60 APPLIED LIFE SCIENCES↗

SU-E-T-617: A Feasibility Study of Navigation Based Multi Criteria Optimization for Advanced Cervical Cancer IMRT Planning

Purpose: This study aims to validate multi-criteria optimization (MCO) against standard intensity modulated radiation therapy (IMRT) optimization for advanced cervical cancer in RayStation (v2.4, RaySearch Laboratories, Sweden). Methods: 10 advanced cervical cancer patients IMRT plans were randomly selected, these plans were designed with step and shoot optimization, new plans were then designed with MCO based on these plans,while keeping optimization conditions unchanged,comparison was made between both kinds of plans including the dose volume histogram parameters of PTV and OAR,and were analysed by pairing-t test. Results: We normalize the plan so that 95% volume of PTV achieved the prescribed dose(50Gy). The volume of radiation 10, 20, 30, and 40 Gy of the rectum were reduced by 14.7%,26.8%,21.1%,10.5% respectively(P≥0.05). The mean dose of rectum were reduced by 7.2Gy(P≤0.05). There were no significant differences for the dosimetric parameters for the bladder. Conclusion: In comparision with standard IMRT optimization, MCO reduces the dose of organs at risk with the same PTV coverage,but the result needs further clinical evalution.

60 APPLIED LIFE SCIENCES↗

SU-E-T-618: Dosimetric Comparison of Manual and Beam Angle Optimization of Gantry Angles in IMRT for Cervical Cancer

Purpose: To evaluate the dosimetric characteristics of intensity-modulated radiotherapy (IMRT) treatment plan with beam angle optimization. Methods: Ten post-operation patients with cervical cancer were included in this analysis. Two IMRT plans using seven beams were designed in each patient. A standard coplanar equi-space beam angles were used in the first plan (plan 1), whereas the selection of beam angle was optimized by beam angle optimization algorithm in Varian Eclipse treatment planning system for the same number of beams in the second plan (plan 2). Two plans were designed for each patient with the same dose-volume constraints and prescription dose. All plans were normalized to the mean dose to PTV. The dose distribution in the target, the dose to the organs at risk and total MU were compared. Results: For conformity and homogeneity in PTV, no statistically differences were observed in the two plans. For the mean dose in bladder, plan 2 were significantly lower than plan 1(p<0.05). No statistically significant differences were observed between two plans for the mean doses in rectum, left and right femur heads. Compared with plan1, the average monitor units reduced 16% in plan 2. Conclusion: The IMRT plan based on beam angle optimization for cervical cancer could reduce the dose delivered to bladder and also reduce MU. Therefore there were some dosimetric advantages in the IMRT plan with beam angle optimization for cervical cancer.

60 APPLIED LIFE SCIENCES↗

Sci—Fri AM: Mountain — 05: Unified Optimization and Delivery of Intensity-modulated Radiation Therapy and Volume-modulated Arc Therapy

Purpose: To study the feasibility of a unified intensity-modulated arc therapy (UIMAT) that combines IMRT and VMAT optimization and delivery in order to produce efficient and superior radiation treatment plans. Methods: Inverse planning for UIMAT was prototyped on the Pinnacle treatment planning system (Philips Medical Systems). UIMAT integrates IMRT and VMAT delivery in the same arc where IMRT was delivered with gantry speed close to zero. Optimal gantry angles for the IMRT phases were selected automatically by the inverse optimization algorithm. Optimization of the VMAT phases and IMRT phases were done simultaneously using Pinnacle's direct machine parameter optimization algorithm. Five treatment plans each for prostate, head and neck, and lung were generated using our unified technique and compared with clinical VMAT or IMRT plans. Delivery verification was performed on an ArcCheck phantom (Sun Nuclear) and delivered in clinical mode on a Varian TrueBeam linear accelerator. Results: In this prototype implementation, compared to the VMAT or IMRT plans, with the plans normalized to the same dose coverage to the planning target volumes, the UIMAT plans produced improved OAR sparing for head and neck cases, while for lung and prostate cases, the dosimetric improvements for OARs were not as significant. In this proof-of-concept work, we demonstrated that a novel radiation therapy delivery technique combining VMAT and IMRT delivery in the same arc is feasible. Initial results showed UIMAT has the potential to be superior to either standard IMRT or VMAT.

60 APPLIED LIFE SCIENCES↗

Novel tools for stepping source brachytherapy treatment planning: Enhanced geometrical optimization and interactive inverse planning

Purpose: Dose optimization for stepping source brachytherapy can nowadays be performed using automated inverse algorithms. Although much quicker than graphical optimization, an experienced treatment planner is required for both methods. With automated inverse algorithms, the procedure to achieve the desired dose distribution is often based on trial-and-error. Methods: A new approach for stepping source prostate brachytherapy treatment planning was developed as a quick and user-friendly alternative. This approach consists of the combined use of two novel tools: Enhanced geometrical optimization (EGO) and interactive inverse planning (IIP). EGO is an extended version of the common geometrical optimization method and is applied to create a dose distribution as homogeneous as possible. With the second tool, IIP, this dose distribution is tailored to a specific patient anatomy by interactively changing the highest and lowest dose on the contours. Results: The combined use of EGO–IIP was evaluated on 24 prostate cancer patients, by having an inexperienced user create treatment plans, compliant to clinical dose objectives. This user was able to create dose plans of 24 patients in an average time of 4.4 min/patient. An experienced treatment planner without extensive training in EGO–IIP also created 24 plans. The resulting dose-volume histogram parameters were comparable to the clinical plans and showed high conformance to clinical standards. Conclusions: Even for an inexperienced user, treatment planning with EGO–IIP for stepping source prostate brachytherapy is feasible as an alternative to current optimization algorithms, offering speed, simplicity for the user, and local control of the dose levels.

60 APPLIED LIFE SCIENCES↗