Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operational Stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Dynamic Interaction of Grid-Forming and Grid-Following Inverters with Synchronous Generators in Hybrid Power Plants

As the integration of renewable energy resources such as wind and solar generation continues to grow, the use of hybrid power plants with both synchronous machines and power electronic inverters operating in parallel becomes more common. This paper studies the impact on small-signal stability for these pairs of devices, first as an isolated two-device system and then as part of a 9-bus test system. Each operational scenario was studied with both a grid-following inverter and a grid-forming inverter. In each scenario, the state variables associated with the synchronous generator's excitation system were found to be responsible for the inception of instability. These results underscore the importance of accurate modeling of excitation systems when modeling power systems with hybrid power plants.

hybrid power plant↗

4 K SRF Operation of the 10 MeV CEBAF Photo-Injector

Superconducting radio-frequency (SRF) accelerating cavities are often operated in superfluid liquid helium with temperature near 2 K to enhance the cavity quality factor Q0 and to help manage heat loads, which are particularly important at large SRF accelerator facilities. This 2 K temperature paradigm, however, need not put SRF technology out of the reach of small institutions or even limit SRF operation at large facilities that need 10-100 MeV beam energy. At the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab there are regularly scheduled maintenance periods during which cryogenic plant often increases the liquid helium temperature from 2 K to 4 K, reducing power consumption by ~ 50 % and saving megawatts of wall-plug power. During recent maintenance periods, we accelerated a continuous-wave electron beam at the CEBAF photo-injector to a total energy of 6.3 MeV at currents up to 80 uA using two 5-cell niobium cavities in the quarter-cryomodule at 4 K. This contribution describes the SRF and cryogenic performance and uses measured beam quality and energy stability as key metrics. These measurements indicate that 4 K operation of niobium SRF cavities in CEBAF is a sensible and cost effective mode for high quality beam operation, provided the cryogenic load associated with lower Q0 is manageable for the number of cavities needed to operate. For Jefferson Lab, this enhances our scientific reach allowing additional low-energy ~ 10 MeV experiments each year.

Drury, Michael↗

Toward Higher Voltage Solid-State Batteries by Metastability and Kinetic Stability Design

The energy density of battery systems is limited largely by the electrochemical window of the electrolyte. Here, the combined thermodynamic and kinetic effects of mechanically induced metastability are shown to greatly widen the operational voltage window of solid-state batteries based on ceramic-sulfide electrolytes. Solid electrolyte voltage stability up to 10 V is achieved with minimal degradation, far beyond the capability of organic liquid electrolytes. Furthermore, combined experiment, ab initio computation, and theoretical modeling identify the nature of mechanically constrained Li 10 GeP 2 S 12 decomposition both within the bulk and at interfaces with cathode materials at very high voltages. Previously unclear kinetic processes are identified that, when properly implemented, can potentially allow solid-state full cells with remarkably high operational voltages.

25 ENERGY STORAGE↗

Impact of Load Tap Changer Control Operation Under Microgrid Conditions

Every microgrid is unique in its diversity of assets, operation, and network structure. This uniqueness presents challenges for each microgrid implementation that need to be understood and addressed to prevent power quality concerns, stability issues, and blackouts. In this research work, we present one challenge faced during microgrid operation that could potentially cause a blackout in some microgrid configurations. Through the incorrect operation of the load tap changer controller during an islanding event for a microgrid with generation present on both primary and secondary busses, the primary voltage will increase or decrease beyond allowable bounds, causing a cascading failure. This work presents the issue first with simulation results to demonstrate the phenomenon and then presents results of load tap changer controller operation using a controller-hardware-in-the-loop experiment. Finally, details of the complete sequence of operation and the blackout scenarios are presented and summarized.

blackout↗

Experimental Studies of Low-Load Limit in a Stoichiometric Micro-Pilot Diesel Natural Gas Engine

While operating at light loads, diesel pilot-ignited natural gas engines with lean premixed natural gas suffer from poor combustion efficiency and high methane emissions. This work investigates the limits of low-load operation for a micro-pilot diesel natural gas engine that uses a stoichiometric mixture to enable methane and nitrogen oxide emission control. By optimizing engine hardware, operating conditions, and injection strategies, this study focused on defining the lowest achievable load while maintaining a stoichiometric equivalence ratio and with acceptable combustion stability. A multi-cylinder diesel 6.7 L engine was converted to run natural gas premix with a maximum diesel micro-pilot contribution of 10%. With a base diesel compression ratio of 17.3:1, the intake manifold pressure limit was 80 kPa(absolute). At a reduced compression ratio of 15:1, this limit increased to 85 kPa, raising the minimum stable load. Retarding the combustion phasing, typically used in spark-ignition engines to achieve lower loads, was also tested but found to be limited by degraded diesel ignition at later timings. Reducing the pilot injection pressure improved combustion stability, as did increasing pilot quantity at the cost of lower substitution ratios. The lean operation further reduced load but increased NOx and hydrocarbon emissions. At loads below the practical dual-fuel limit, a transition to lean diesel operation will likely be required with corresponding implications for the aftertreatment system.

03 NATURAL GAS↗

Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Coal and Biomass – Integration of Combustor Boiler and DCC

Utilities and grid operators worldwide are under significant pressure to incorporate intermittent renewable sources while strategizing on how to maintain the necessary stability and reliability of the grid. The development of a power plant which will be capable of flexible operation to meet the needs of the grid as more intermittent sources like wind and solar energy are incorporated is key to maintain the reliability of the grid. Through the use of innovative and cutting-edge technologies that improve efficiency and reduce carbon emissions, and being small compared to today's conventional utility-scale power plants, the modular Staged, Pressurized Oxy-Combustion (SPOC) process envisioned by and under development at Washington University in St. Louis (WUSTL) has the potential to achieve these goals. Specifically, the process offers: 1) a modular plant design that allows for better operational flexibility; 2) the utilization of fuel-staging and pressurized oxy-combustion, resulting in smaller plant size, improved plant efficiency, and reduced costs for pollutant and CO2 removal compared to traditional power plants with post-combustion capture technology; and 3) the use of small modular boilers and pollutant removal units that can be constructed off-site leading to reduced capital costs for the plant. WUSTL is advancing the development of the critical components for the SPOC power plant, including the integrated combustor-boiler system and the direct contact cooler. To demonstrate the boiler convective section and to obtain critical data for commercial-scale pressurized boiler design, a simulated convective heat transfer boiler test section was designed and integrated with the combustor (radiant section). A direct contact cooler (DCC) was integrated with the combustor-boiler to demonstrate the dynamic operation of the integrated system and the performance of the DCC, including the efficiency for simultaneous removal of NOx and SOx. This talk will present an update on the evaluation of the critical components for system integration, including heat transfer data from the simulated boiler, scrubbing efficiency for the DCC under different operating conditions, and CFD modeling and validation for burner and boiler development.

Magalhaes, Duarte↗

An Aerosol Jet Printed Resistance Temperature Detector‐Micro Hotplate with Temperature Coefficient of Resistance Stabilized by Electrical Sintering

Abstract Aerosol jet printing (AJP) is an emerging direct write tool enabling rapid prototyping and fabrication of electronics components. AJP provides faster and less expensive production of devices with feature sizes of >10 microns compared to traditional MEMS processes. Herein, the fabrication of a resistance temperature detector‐micro hotplate (RTD‐µHP) is reported using AJP printed silver. AJP eliminates sophisticated MEMS processes such as masking, alignment, and etching. The compatibility of the AJP process with a broad range of materials is demonstrated by printing highly resolved lines on rigid and flexible substrates. Optimal thermal sintering conditions of AJP printed silver (Ag) lines are found by in situ resistance measurements. To stabilize the temperature coefficient of resistance (TCR) of the RTD‐µHP at high operating current levels, electrical sintering is performed on the RTD‐µHPs. Electrical sintering improves the conductivity of fully thermally sintered Ag RTD‐µHPs by 32% and provides a burn‐in mechanism for stabilizing the TCR. The TCR of the RTD‐µHPs after electrical sintering is 3.80 × 10 −3 at 22 °C, close to the value for bulk Ag. The performance of the RTD‐µHPs is tested using a reference thermocouple. The RTD‐µHPs show reliable and repeatable heating and temperature sensing up to 70 °C in air.

Sui, Yongkun↗

Design and fabrication of a CMOS-compatible MHP gas sensor

A novel micro-hotplate (MHP) gas sensor is designed and fabricated with a standard CMOS technology followed by post-CMOS processes. The tungsten plugging between the first and the second metal layer in the CMOS processes is designed as zigzag resistor heaters embedded in the membrane. In the post-CMOS processes, the membrane is released by front-side bulk silicon etching, and excellent adiabatic performance of the sensor is obtained. Pt/Ti electrode films are prepared on the MHP before the coating of the SnO{sub 2} film, which are promising to present better contact stability compared with Al electrodes. Measurements show that at room temperature in atmosphere, the device has a low power consumption of ∼19 mW and a rapid thermal response of 8 ms for heating up to 300 °C. The tungsten heater exhibits good high temperature stability with a slight fluctuation (<0.3%) in the resistance at an operation temperature of 300 °C under constant heating mode for 336 h, and a satisfactory temperature coefficient of resistance of about 1.9‰/°C.

36 MATERIALS SCIENCE↗

Tevatron End-of-Run Beam Physics Experiments

Before the Tevatron Collider Run II ended in September of 2011, a number of specialized beam study periods were dedicated to the experiments on various accelerator physics concepts and effects during the last year of the machine operation. The study topics included collimation with bent crystals and hollow electron beams, diffusion measurements and various aspects of beam-beam interactions. In this report we concentrate on the subject of beam-beam interactions, summarizing the results of beam experiments. The covered topics include offset collisions, coherent beam stability, effect of the bunch-length-to-beta-function ratio, and operation of AC dipole with colliding beams.

43 PARTICLE ACCELERATORS↗

Confinement Reconstruction Unlocks Stable Ru Single Atom-Doped IrO x Anodes for Long-Term High-Rate CO 2 Electrolysis

IrO 2 is a commonly employed anode catalyst for CO 2 electrolysis in membrane electrode assembly (MEA) systems. However, under high current densities, its structural reconstruction leads to activity loss and stability degradation, limiting the industrial viability of CO 2 electrolysis. In this work, we demonstrated a confinement reconstruction strategy to precisely regulate the structural evolution during electrolysis. Ethylene glycol serves as a structural modulator, protecting the catalyst surface, suppressing soluble species formation, and promoting ordered structural evolution. Single-atom Ru acts as a stability enhancer, forming robust Ir–O–Ru bridging structures that facilitate an ordered transformation from a 4-fold [RuO 4 ]/[IrO 4 ] to a 6-fold symmetry [RuO 6 ]/[IrO 6 ] octahedral framework, thereby enhancing structural rigidity and long-term stability. As a result, in MEA-based CO 2 electrolysis, the catalyst achieves a stable operation at 200 mA cm –2 for 480 h, maintaining a CO selectivity above 80%. Theoretical calculations further elucidate that the enhanced stability originates from the suppression of oxygen vacancy formation, making the lattice-oxygen-mediated mechanism (LOM) potentially less favorable. This work provides insights into the structural evolution of the OER catalysts under high-current-density conditions, paving the way for large-scale CO 2 electrolysis commercialization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Breaking the Current‐Retention Dilemma in Cation‐Based Resistive Switching Devices Utilizing Graphene with Controlled Defects

Abstract Cation‐based resistive switching (RS) devices, dominated by conductive filaments (CF) formation/dissolution, are widely considered for the ultrahigh density nonvolatile memory application. However, the current‐retention dilemma that the CF stability deteriorates greatly with decreasing compliance current makes it hard to decrease operating current for memory application and increase driving current for selector application. By centralizing/decentralizing the CF distribution, this current‐retention dilemma of cation‐based RS devices is broken for the first time. Utilizing the graphene impermeability, the cation injecting path to the RS layer can be well modulated by structure‐defective graphene, leading to control of the CF quantity and size. By graphene defect engineering, a low operating current (≈1 µA) memory and a high driving current (≈1 mA) selector are successfully realized in the same material system. Based on systematically materials analysis, the diameter of CF, modulated by graphene defect size, is the major factor for CF stability. Breakthrough in addressing the current‐retention dilemma will instruct the future implementation of high‐density 3D integration of RS memory immune to crosstalk issues.

Zhao, Xiaolong↗

Managing an Aging Pump-and-Treat Groundwater Remediation System at the Fernald Preserve - 19557

The Fernald Preserve, Ohio, Site underwent restoration and remediation under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). With the exception of the Great Miami Aquifer, the CERCLA remediation was declared physically complete on October 29, 2006, and the site was turned over to the US Department of Energy Office of Legacy Management for long-term care and maintenance. The Record of Decision under CERCLA specifies a concentration-based cleanup that requires the extraction and treatment of Great Miami Aquifer groundwater above Final Remediation Levels (FRLs) until the full, beneficial use potential of the aquifer is achieved, including use as a drinking water source. The area of the aquifer targeted for remediation is 126.5 hectares (312.70 acres). The groundwater pumping remediation was designed by modeling cleanup with the Variable Saturated Analysis Model in 3 Dimensions (VAM-3D) modeling code, developed by Hydrogeologic Inc. The original design called for 23 extraction wells operating at 379 liters per minute (lpm) (100 gallons per minute [gpm]) to 1135 lpm (300 gpm) each for a system total of 18,073 lpm (4775 gpm). In 2014, the system was optimized down to 20 extraction wells operating at 379 to 1893 lpm each for a system total of 19,180 lpm (5075 gpm). To date, pumping has been an effective remediation technology for the aquifer. At the end of 2017, the area of the aquifer remaining above FRLs was down to 38.2 hectares (94.4 acres). From August 1993 through December 2017 (24 years), 6235 kilograms (kg) (13,733 pounds) of uranium were removed from the aquifer by the pumping of 1.74 x 10{sup 11} liters (46.2 billion gallons) of water. Since 2010, treatment of groundwater to achieve regulatory discharge limits at the Great Miami River has not been needed on a routine basis. The ongoing remediation is now essentially a pumping operation, and this water does not require treatment. Metrics reported in the annual Site Environmental Report for the groundwater remediation indicate that, based on the model-predicted estimate of the mass of uranium that needs to be removed from the aquifer to achieve a concentration-based cleanup, the cleanup is approximately 86% - 87% complete. Current model predictions indicate that pumping will need to continue an additional 16 years (until 2035) in some of the wells. During the additional 16 years, it is estimated that approximately 1012 kg (2231 pounds) of uranium will be removed from the aquifer. System pumping rates are designed to decrease over the course of the remaining 16 years, dropping down to a system total of 11,638 lpm (3075 gpm) in 2022 and a system total of 4163 lpm (1100 gpm) in 2033. Even with the designed decreases in pumping rates, it is estimated that approximately 1 x 10{sup 11} liters (26.6 billion gallons) of water will be pumped from the aquifer to remove 1012 kg (2231 pounds) of uranium. This indicates that the remaining 16 years of operation will be much less efficient than the first 24 years. Decreasing efficiency is common for pumping operations. The worst-case scenario is that decreasing concentration trends stabilize above the cleanup FRLs and remediation goals are never achieved. Performance assessments of the pumping remedy will need to be routinely conducted to determine if pumping should be discontinued, if it should be continued but optimized, or if the pumping technology can be supplemented with a different technology that will improve the outcome of the remediation and make the operation more efficient and successful. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deviations from Vegard's law and evolution of the electrocatalytic activity and stability of Pt-based nanoalloys inside fuel cells by in operando X-ray spectroscopy and total scattering

Catalysts for energy related applications, in particular metallic nanoalloys, readily undergo atomic-level changes during electrochemical reactions. The origin, dynamics and implications of the changes for the catalysts’ activity inside fuel cells though are not well understood. This is largely because they are studied on model nanoalloy structures under controlled laboratory conditions. Here we use combined synchrotron X-ray spectroscopy and total scattering to study the dynamic behaviour of nanoalloys of Pt with 3d-transition metals as they function at the cathode of an operating proton exchange membrane fuel cell. Results show that the composition and atomic structure of the nanoalloys change profoundly, from the initial state to the active form and further along the cell operation. The electrocatalytic activity of the nanoalloys also changes. The rate and magnitude of the changes may be rationalized when the limits of traditional relationships used to connect the composition and structure of nanoalloys with their electrocatalytic activity and stability, such as Vegard's law, are recognized. In particular, deviations from the law inherent for Pt-3d metal nanoalloys can well explain their behaviour under operating conditions. Moreover, it appears that factors behind the remarkable electrocatalytic activity of Pt-3d metal nanoalloys, such as the large surface to unit volume ratio and “size misfit” of the constituent Pt and 3d-transition metal atoms, also contribute to their instability inside fuel cells. The new insight into the atomic-level evolution of nanoalloy electrocatalysts during their lifetime is likely to inspire new efforts to stabilize transient structure states beneficial to their activity and stability under operating conditions, if not synthesize them directly.

25 ENERGY STORAGE↗

On the stability of topological phases on a lattice

We study the stability of anyonic models on lattices to perturbations. We establish a cluster expansion for the energy of the perturbed models and use it to study the stability of the models to local perturbations. We show that the spectral gap is stable when the model is defined on a sphere, so that there is no ground state degeneracy. We then consider the toric code Hamiltonian on a torus with a class of abelian perturbations and show that it is stable when the torus directions are taken to infinity simultaneously, and is unstable when the thin torus limit is taken.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Durable, pure water–fed, anion-exchange membrane electrolyzers through interphase engineering

Anion-exchange membrane water electrolyzers (AEMWEs) promise scalable, low-cost hydrogen production but are limited by the electrochemical instability of their anode ionomers. We report interphase engineering using inorganic-containing molecular additives that coassemble with ionomer, enabling pure water-fed AEMWEs to operate with a degradation rate <0.5 millivolt per hour at 2.0 amperes per square centimeter and 70°C-a >20-fold durability improvement. Analysis of different additives and ionomers shows that the stabilization mechanism involves cross-links between metal oxo/hydroxo oligomers and ionomers. Under operation, the inorganic additive enriches, forming an interphase near the water-oxidation catalyst that passivates the anode ionomer against continuous degradation while maintaining mechanical integrity and hydroxide conductivity. This additive-based interphase-engineering strategy provides a path to durable AEMWEs that operate without supporting electrolytes and is adaptable across diverse catalysts and ionomers for electrochemical technologies.

Hou, Shujin↗

Extracting Topological Orders of Generalized Pauli Stabilizer Codes in Two Dimensions

In this paper, we introduce an algorithm for extracting topological data from translation invariant generalized Pauli stabilizer codes in two-dimensional systems, focusing on the analysis of anyon excitations and string operators. The algorithm applies to Z d qudits, including instances where d is a nonprime number. This capability allows the identification of topological orders that differ from the Z d toric codes. It extends our understanding beyond the established theorem that Pauli stabilizer codes for Z p qudits (with p being a prime) are equivalent to finite copies of Z p toric codes and trivial stabilizers. The algorithm is designed to determine all anyons and their string operators, enabling the computation of their fusion rules, topological spins, and braiding statistics. The method converts the identification of topological orders into computational tasks, including Gaussian elimination, the Hermite normal form, and the Smith normal form of truncated Laurent polynomials. Furthermore, the algorithm provides a systematic approach for studying quantum error-correcting codes. We apply it to various codes, such as self-dual CSS quantum codes modified from the two-dimensional honeycomb color code and non-CSS quantum codes that contain the double semion topological order or the six-semion topological order. Published by the American Physical Society 2024

Physics↗

Vacuum (meta)stability beyond the MSSM

We study the stability of the Higgs potential in the framework of the effective Lagrangian beyond the minimal supersymmetric standard model (MSSM). While the leading nonrenormalizable operators can shift the Higgs boson mass above the experimental bound, they also tend to render the scalar potential unbounded from below. The destabilization is correlated with the Higgs mass increase, so that if quantum corrections are small the problem is severe. We show that a supersymmetric subleading correction stabilizes the potential within the domain of validity of the effective theory. Constraints on MSSM parameters as well as on higher dimensional operators are derived, ensuring that our vacuum has a lifetime longer than the present age of the Universe. In addition we show that when effective operators are responsible for evading the LEP bound, stability constraints imply an upper bound on the scale of new physics in the few TeV range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Stabilizer based Predictive Control Scheme for Smart Inverters in Weak Grid

This paper presents a self-stabilization mechanism based on finite-set model predictive control (FCS-MPC) framework for smart inverters operating in weak grid conditions. As weak grid’s large parasitic impedance and low short-circuitratio (SCR) challenge the stable operation of grid-connected inverters. Specifically, the inverter may experience frequencies that might excite the LCL filter resonance phenomenon. The inverter stability collapses if this LCL resonance is triggered. To address this issue, a robust predictive controller is proposed that features a self-stabilization mechanism for smart inverters interacting with a weak grid. The proposed methodology utilizes the idea that in stiff grid conditions the grid current feedback (GCF) is stable and in weak grid conditions the inverter current feedback (ICF) is stable. Therefore, the proposed FCS-MPC toggles between GCF and ICF to achieve inherent LCL filter resonance damping. The toggling action between GCF and ICF is leveraged by comparing the moving RMS grid current with threshold current as a constrained in the proposed FCS-MPC cost function. The theoretical analyses are verified by several case studies for a single-phase grid-connected inverter. The analysis and results demonstrated that the proposed FCS-MPC operates well under weak, ultra-weak and stiff grid conditions.

Umar, Muhammad Farooq↗