Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear level density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Potential absence of observed π2 linear-chain structures in 14O via 10C(α,α) resonances scattering

Background: The preference for light nuclear systems to coagulate into -particle clusters has been well-studied. The possibility of a linear chain configuration of -particles would allow for a new way to study this phenomenon. Purpose: A rotational band of states in C has been claimed showing a linear chain structure. The mirror system, O, has been studied here to examine how this linear chain structure is affected by replacing the valence neutrons with protons. Method: A beam of C was incident into a chamber filled with He:CO gas with the tracks recorded inside the TexAT Time Projection Chamber and the recoil -particles detected by a silicon detector array to measure the cross section. Results: The experimental cross section was compared with previous studies and fit using R-Matrix theory with the previously-observed O states being transformed to the C using mirror symmetry. The measured cross section does not replicate the claimed states, with the predicted cross section exceeding that observed at several energies and angles. Conclusion: A series of possibilities are highlighted with the most likely being that the originally-seen C states did not constitute a rotational band with a potentially incorrect spin assignment due to the limitations of the angular correlation method with non-zero spin particles. The work highlights the difficulties in measuring broad resonances corresponding to a linear chain state in a high level density.

Bishop, J.↗

Neutronics Studies of Uranium-bearing Fully Ceramic Micro-encapsulated Fuel for PWRs

Our study evaluated the neutronics and some of the fuel cycle characteristics of using uranium-based fully ceramic microencapsulated (FCM) fuel in a pressurized water reactor (PWR). Specific PWR lattice designs with FCM fuel have been developed that are expected to achieve higher specific burnup levels in the fuel while also increasing the tolerance to reactor accidents. The SCALE software system was the primary analysis tool used to model the lattice designs. A parametric study was performed by varying tristructural isotropic particle design features (e.g., kernel diameter, coating layer thicknesses, and packing fraction) to understand the impact on reactivity and resulting operating cycle length. Moreover, to match the lifetime of an 18-month PWR cycle, the FCM particle fuel design required roughly 10% additional fissile material at beginning of life compared with that of a standard uranium dioxide (UO 2 ) rod. Uranium mononitride proved to be a favorable fuel for the fuel kernel due to its higher heavy metal loading density compared with UO 2 . The FCM fuel designs evaluated maintain acceptable neutronics design features for fuel lifetime, lattice peaking factors, and nonproliferation figure of merit.

10 SYNTHETIC FUELS↗

Roll Compaction of Powdered Radioactive Wastes - 18251

Most of low- and intermediate-level radioactive wastes must be solidified by a proper binding matrix and disposed at the centralized disposal site. So it is desirable to achieve a high loading of radwastes in a drum to reduce the disposal fee while meeting both the national regulations and the waste acceptance criteria of the disposal site. In general, the radioactive wastes (liquid, dried powder and sludge) were solidified by mixing with a proper binding matrix (cement, polymer, asphalt, etc.), but their solidified volume inevitably increases due to the limitation of incorporating of radwaste into a binding matrix. To solve this problem, some Korean NPPs operate both a CTS (Concentrate Treatment System, evaporation and granulation) and a polymer solidification system. The size distribution of granulated wastes produced by CTS is so broad (diameter; several μm ∼ several cm) that a polymer cannot impregnate the void space between particles due to their small size. However, if the powdered radwaste can be compacted into high density pellets, and the pellets can be loaded in a drum with maximum waste loading, then the binding matrix can fill the void between pellets, it might be more desirable to keep the size distribution of pellets constant to reduce the solidified waste volume. This compaction methodology can greatly reduce the disposal fee due to the reduction of the solidified waste volume, and can facilitate polymer solidification due to the constant size of the radwaste pellets. This methodology is also applicable to solidify powdered wastes such a depleted uranium used as a catalyst, ash and sludge. Loading radwaste compacted with bentonite pellets versus particles into a container serves, as an engineered or natural barrier in a deep geologic disposal system. Roll compaction is a typical agglomeration process for dry powders and depends on the device parameters and the material properties. This study, firstly, was focused on the design of roll compactor (briquetting machine), the shape and size of pellet, and secondly the loading method of pellets into a drum, their solidification in polymer, and evaluating the overall volume reduction. We used bentonite (particle size; 85 ∼ 100 μm) as a material to be compacted instead of radwaste powders (concentrates and depleted uranium wastes) without the addition of agglomeration agents. In the design of roll, we considered the diameter (200 mm) and width (41 mm) of roll, two types of pocket shapes (< 9 mm, 0.275 ml), and the surface of the pocket. Fig. 2 shows two pellet shapes, tetragonal and circular. The pressure of roll compactor, one of the main process variables, is > 320 kg f/cm{sup 2}, and the roll gap is 0.5 mm. The powders are compacted in a compaction zone between two counter-rotating rolls according to the complicated mechanisms. As a result of the state and the apparent density of the pellets obtained by changing the pressure from 0 to 286 kg f/cm{sup 2}, the pellets were unstable at pressure=0, but above 148 kg f/cm{sup 2} the pellets were more stable, and the apparent density of the pellets was 2.63 g/cm{sup 3} at 148 kg f/cm{sup 3}, and 2.68 g/cm{sup 3} at 286 kg f/cm{sup 2}. The roller speed (rpm) can determine the capacity (kg/h) of a compactor, and depends on both the compaction pressure and the feeding rate. By increasing the roll speed from 2 to 4 rpm, the apparent density of pellets was decreased gradually from 2.74 g/cm{sup 3} to 1.45 g/cm{sup 3}. We designed the special feeding system in order to feed powders uniformly to the roll gripping zone and to supply powders into the narrowest part of the roll gap. At a constant roll speed (3 rpm) and a constant compaction pressure (286 kg f/cm{sup 2}), the apparent density of the pellets was linearly proportional to the feeding rate from 2.18 to 2.74 g/cm{sup 3} by changing the feeding rate of powders from 8 to 12 rpm. In the polymer solidification of the obtained pellets, we used epoxy resin as a solidification agent, and showed their solidified waste forms in Fig. 5. The incorporation ratio (wt.%) of powders/polymer was about 71.7/28.3 in tetragonal pellets, 71.9/28.1 in circular pellets. We calculated the volume reduction in an aspect of powders itself and the solidified waste form. In powder case, through the comparison of the apparent density of the obtained pellets (2.74 g/cm{sup 3}) and raw powders (0.93 g/cm{sup 3}), the volume reduction was calculated as about 2.74/0.93 = 2.95 times. This means that powders can be compacted to 1/2.95 times. And in waste form case, the weight ratio of powder/polymer in a mixing method (workable) and a compaction method is about 0.42, 2.56, individually. Therefore the volume reduction was calculated as about 2.56/0.42 = 6.01 times. We found a compaction methodology for the volume reduction of powdered radioactive wastes, and their polymer solidification will be more effective to reduce the volume of radwastes to be disposed. After a characterization of the solidified waste form incorporated pellets (including sintered pellets), this methodology will be applied to treat depleted uranium wastes used as catalyst, and to solve the problem of NPPs' polymer solidification system, as mentioned above. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RADIATIVE OPACITY OF IRON STUDIED USING A DETAILED LEVEL ACCOUNTING MODEL

The opacity of iron plasma in local thermodynamic equilibrium is studied using an independently developed detailed level accounting model. Atomic data are generated by solving the full relativistic Dirac-Fock equations. State mixing within one electronic configuration is considered to include part of the correlations between electrons without configuration interaction matrices that are too large being involved. Simulations are carried out and compared with several recent experimental transmission spectra in the M- and L-shell absorption regions to reveal the high accuracy of the model. The present model is also compared with the OPAL, LEDCOP and OP models for two isothermal series at T = 20 eV and T = 19.3 eV. It is found that our model is in good agreement with OPAL and LEDCOP while it has discrepancies with OP at high densities. Systematic Rosseland and Planck mean opacities in the range 10-1000 eV for temperature and 10{sup -5}-10{sup -1} g cm{sup -3} for density are also presented and compared with LEDCOP results, finding good agreement at lower temperatures but apparent differences at high temperatures where the L- and K-shell absorptions are dominant.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Drop Analysis of the Advanced Test Reactor Fresh Fuel Shipping Container with Heavier Low-Enriched Uranium Fuel Contents

The Advanced Test Reactor Fresh Fuel Shipping Container (ATR FFSC) is a rectangular stainless steel container used for shipping radioactive material. The container is described in the ATR FFSC Safety Analysis Report (SAR). Per the ATR FFSC SAR, the ATR FFSC is designated a Type AF-96 packaging per the definition of 10 CFR §71.4, and was originally designed to transport high enriched uranium (HEU) reactor fuel elements for the Advanced Test Reactor (ATR), the Advanced Test Reactor Critical (ATRC) facility, the Massachusetts Institute of Technology Reactor (MITR), and the University of Missouri Research Reactor (MURR). The Department of Energy, National Nuclear Security Administration’s (NNSA), Office of Material Management and Minimization (M3) is working with the Idaho National Laboratory (INL) to develop and qualify new low enriched uranium (LEU) fuels and technologies for use in the ATR, ATRC, MITR, and MURR reactors. The LEU fuel elements will weigh significantly more than the current HEU designs and, combined with their associated Fuel Handling Enclosures for packaging, some configurations will exceed the 50 lbf used in the ATR FFSC qualifying drop tests. There are LEU versions of MITR, MURR, and ATR fuel elements. However, for this evaluation, drop analysis of the ATR FFSC with only the heavier ATR Low Enrichment (LOWE) fuel element is considered in this evaluation because the LOWE fuel element is the heaviest of the considered LEU fuel elements. The ATR HEU fuel element and the ATR LOWE fuel element are identical in every design aspect except for the fuel meat inside the 19 fuel plates. The LEU fuel meats are made using a U-10Mo high-density foil rather than uranium dispersed in aluminum in the HEU fuel elements. The high density of the uranium in the LEU fuel meat increases the LOWE fuel element weight to just under 44 lbf (versus the 22.1 lbf weight of the tested ATR HEU fuel element). ATR fuel elements are placed in a thin-gauge aluminum weldment called a "Fuel Handling Enclosure" during packaging. The Fuel Handling Enclosure is used to cover and protect the element during loading and unloading operations. The ATR Fuel Handling Enclosure weighs about 15 lbf per the drawings in the ATR FFSC SAR and the weight is accounted for in this evaluation. Transporting the heavier LEU fuel elements require evaluation of two issues. The first is the effect of the increased mass of the LEU fuel elements on the survivability of the ATR FFSC package following the requisite drop qualifications. The second is the effect of the increased mass of the fuel plates on the fuel element during the same drops. The ATR FFSC containing an ATR HEU fuel element in an ATR Fuel Handling Enclosure was physically dropped multiple times to qualify the container as a Type AF-96 package. The ATR FFSC SAR describes the drop tests performed with an actual ATR HEU fuel element weighing 22.1 lbf contained in a 14.3 lbf Fuel Handling Enclosure for a total payload of 36.4 lbf. Those drop tests showed that the ATR FFSC maintained containment of the ATR HEU fuel element and the fuel element was not significantly damaged. (Containment herein is not defined as a leak tight but is retention of the radioactive contents.) The purpose of the evaluation is to analytically show that, for a similar set of tests, the ATR FFSC maintains containment of the heavier ATR LOWE fuel element and to assess the damage to the fuel element during the drops. The approach was to create finite element analysis (FEA) models that produce the same results as the physical drops. Those models were then used as the benchmarks for the follow-on analyses using the heavier contents. FEA models of the drops of ATR FFSC using up to a 115 lbf fuel element were run and evaluated. Likewise, drops of a LOWE fuel element weighing 44 lbf in the ATR FFSC were run and evaluated. It is important to note that this report was done at the quality level necessary to be included in a nuclear facility safety basis. However, it is not the intent of this report to conclude the suitability of the ATR FFSC for transporting the heavier payloads. This report only describes the results of the FEA as related to the required drop scenarios. Incorporation of the FEA into the safety basis will be evaluated by the ATR FFSC design authority. The physical drop tests of the HEU fuel element and FEA drop analysis for the LOWE fuel element showed noteworthy damage to the fuel plates. An aluminum protective block was conceived to mitigate the damage. The concept requires the blocks to be placed in the fuel element between the end boxes and fuel plates. Additional FEA drop analyses were performed using the protective block. The addition of the blocks is primarily intended to mitigate the damage to the LOWE fuel element fuel plates. However, FEA drop analyses of the ATR HEU fuel element with the blocks were also performed and included for information.

42 ENGINEERING↗

Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization

Purpose: Dual-energy CT (DECT) is being increasingly used for its capability of material decomposition and energy-selective imaging. A generic problem of DECT, however, is that the decomposition process is unstable in the sense that the relative magnitude of decomposed signals is reduced due to signal cancellation while the image noise is accumulating from the two CT images of independent scans. Direct image decomposition, therefore, leads to severe degradation of signal-to-noise ratio on the resultant images. Existing noise suppression techniques are typically implemented in DECT with the procedures of reconstruction and decomposition performed independently, which do not explore the statistical properties of decomposed images during the reconstruction for noise reduction. In this work, the authors propose an iterative approach that combines the reconstruction and the signal decomposition procedures to minimize the DECT image noise without noticeable loss of resolution. Methods: The proposed algorithm is formulated as an optimization problem, which balances the data fidelity and total variation of decomposed images in one framework, and the decomposition step is carried out iteratively together with reconstruction. The noise in the CT images from the proposed algorithm becomes well correlated even though the noise of the raw projections is independent on the two CT scans. Due to this feature, the proposed algorithm avoids noise accumulation during the decomposition process. The authors evaluate the method performance on noise suppression and spatial resolution using phantom studies and compare the algorithm with conventional denoising approaches as well as combined iterative reconstruction methods with different forms of regularization. Results: On the Catphan©600 phantom, the proposed method outperforms the existing denoising methods on preserving spatial resolution at the same level of noise suppression, i.e., a reduction of noise standard deviation by one order of magnitude. This improvement is mainly attributed to the high noise correlation in the CT images reconstructed by the proposed algorithm. Iterative reconstruction using different regularization, including quadratic orq-generalized Gaussian Markov random field regularization, achieves similar noise suppression from high noise correlation. However, the proposed TV regularization obtains a better edge preserving performance. Studies of electron density measurement also show that our method reduces the average estimation error from 9.5% to 7.1%. On the anthropomorphic head phantom, the proposed method suppresses the noise standard deviation of the decomposed images by a factor of ∼14 without blurring the fine structures in the sinus area. Conclusions: The authors propose a practical method for DECT imaging reconstruction, which combines the image reconstruction and material decomposition into one optimization framework. Compared to the existing approaches, our method achieves a superior performance on DECT imaging with respect to decomposition accuracy, noise reduction, and spatial resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring the Neutron Substructure with Advanced Polarized Helium-3 Targets (Or: How I Learned to Stop Worrying and Love Spectroscopy)

As we seek to understand the smallest, physical aspects of our universe, we cannot simply rely on our senses to probe the world around us as we did in the past. The smallest physical elements of our universe behave in strange, probabilistic ways and are completely invisible to the naked eye/ear/etc. So, we design clever experiments (such as scattering experiments) to probe these minute realms. Then, just as with the larger, observable world, we devise models and equations to describe what we think is happening. Due to the nature of the physical universe at the quantum scale and with the aid of symmetries such as Lorentz invariance, we can write down equations that describe the scattering, but the expressions contain functions, which we call ?form factors? and ?structure functions?, that we cannot compute from first principles. We can, however, formulate models that make predictions for these functions. By comparing our predictions with the observed data, we can gain insight into the validity of our models and thus a better physical understanding of what is happening at these minuscule scales. Studying the constituents inside of the nucleus of an atom adds another layer of difficulty if we can?t remove those components from the nucleus. This is the case with the neutron. When not bound in the nucleus with protons and other neutrons, the neutron will decay into a proton after about 15 minutes. So, we?re forced to study the neutron while it is still bound in the nucleus of an atom such as helium-3 (3He). For the last 1,000 years (rounding up), our group has developed high quality, polarized 3He targets made of an aluminosilicate glass. These targets are made in order to perform experiments at Jefferson Lab (JLab), experiments which let us determine the form factors and structure functions of the neutron by scattering polarized electrons from polarized neutrons (or rather polarized 3He). The specific experiments reported on in this thesis push the bounds of our understanding of the internal structure of the neutron. Good science is often about pushing experimental techniques to a new level. Toward that goal we study our polarized 3He targets both to advance the technology and to choose the best ones for our experiments. We do this using a process called nuclear magnetic resonance (NMR) to gauge the maximum polarization of a target and how fast the polarization decays with time. While these tests primarily provide us information that make analysis of our experimental scattering data possible, they also let us determine whether or not a target-cell is useful or even, dare I say, of spectacular quality. Our latest targets utilize a novel convection design allowing 3He to be polarized and quickly moved in front of the electron-beam, making it possible to use larger targets with higher electron-beam currents than ever before. This means more electrons scatter and we get more data. And by studying our targets in detail prior to using them in our experiments, we have found techniques to take effects which could have been detrimental to target quality and turn them to our advantage! It?s a real case of making lemonade out of lemons. We also use laser spectroscopy to study the absorption lines of alkali-metals in the target (potassium and rubidium, specifically). We add these alkali-metals to our target to facilitate polarizing the 3He. We can use the measurement of these pressure broadened absorption lines to determine the 3He density inside of the target with great precision. Historically, we understood the width of these lines would be dependent on the temperature of the target. Specifically, if I raise the temperature, the width should get bigger. I found that was not the case, which was very confusing at first, though very exciting now that I realize the data are self-consistent and suggestive of unexpected behavior. This thesis details the development of high quality, glass, polarized 3He targets for the 2020 An 1 /dn 2 and 2023 Gn E experiments, which utilized the first 3He convection targets and broke records in target quality. This thesis also covers the initial development of metal windows for the next-generation of 3He target-cells. Finally, this thesis documents the temperature dependence of the width of potassium (K) and rubidium (Rb) absorption lines as measured with laser spectroscopy.

Jantzi, Christopher↗

Effects of refractive index mismatch in optical CT imaging of polymer gel dosimeters

Purpose: Proposing an image reconstruction technique, algebraic reconstruction technique-refraction correction (ART-rc). The proposed method takes care of refractive index mismatches present in gel dosimeter scanner at the boundary, and also corrects for the interior ray refraction. Polymer gel dosimeters with high dose regions have higher refractive index and optical density compared to the background medium, these changes in refractive index at high dose results in interior ray bending. Methods: The inclusion of the effects of refraction is an important step in reconstruction of optical density in gel dosimeters. The proposed ray tracing algorithm models the interior multiple refraction at the inhomogeneities. Jacob’s ray tracing algorithm has been modified to calculate the pathlengths of the ray that traverses through the higher dose regions. The algorithm computes the length of the ray in each pixel along its path and is used as the weight matrix. Algebraic reconstruction technique and pixel based reconstruction algorithms are used for solving the reconstruction problem. The proposed method is tested with numerical phantoms for various noise levels. The experimental dosimetric results are also presented. Results: The results show that the proposed scheme ART-rc is able to reconstruct optical density inside the dosimeter better than the results obtained using filtered backprojection and conventional algebraic reconstruction approaches. The quantitative improvement using ART-rc is evaluated using gamma-index. The refraction errors due to regions of different refractive indices are discussed. The effects of modeling of interior refraction in the dose region are presented. Conclusions: The errors propagated due to multiple refraction effects have been modeled and the improvements in reconstruction using proposed model is presented. The refractive index of the dosimeter has a mismatch with the surrounding medium (for dry air or water scanning). The algorithm reconstructs the dose profiles by estimating refractive indices of multiple inhomogeneities having different refractive indices and optical densities embedded in the dosimeter. This is achieved by tracking the path of the ray that traverses through the dosimeter. Extensive simulation studies have been carried out and results are found to be matching that of experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recycle of Am-241 obtained from long term stored plutonium for use in radioisotope power systems - 15035

Pu-238 has been used as a power source for spacecraft since the early days of space exploration. It has proven to be an effective source of power where the use of solar generated power is impractical. Its application for use in spacecraft power systems was developed by the USA and Russia who have spent many $ 100s of millions on its development and production. However, the original facilities for the production of Pu-238 are no longer in use and existing worldwide stockpiles have reduced to levels sufficient for only one or two further missions. Production of Pu-238 requires considerable facilities including a nuclear reactor and reprocessing plants that are very expensive to build and operate. The European Space Agency (ESA) has assessed the options for post-launch power generation in future European space missions and has made the decision to pursue the use of Am-241 as an alternative isotope to power future European Radioisotope Power Systems (RPS). What makes Am-241 attractive for the European market is its 100% isotopically pure production from the decay of Pu-241 in separated civil plutonium stockpiles. Historically, Europe has relied on collaborations with the USA or Russia to access these nuclear power sources. During 2009, the European Space Agency (ESA) funded a project to examine the cost and practicality of establishing a European source of material suitable for Radioisotope Power Systems (RPS). The study concluded that a small number of radioisotopes could be used in RPSs. On further review two leading candidates, Am-241 and Pu-238, were selected for further study. Whilst Pu-238 was recognized as the isotope of choice for use in RPSs, the costs of setting up a European based production facility was prohibitively expensive. Although Am-241 has a number of limitations compared to Pu-238, the much reduced production costs make Am-241 an attractive option for European based production of RPSs. Despite its lower power density of ∼ 0.11 Wth/g, Am-241 is viewed as a potential alternative to Pu-238 because of its availability within the nuclear fuel cycle. During the reprocessing of spent nuclear fuel plutonium is separated as a chemically pure PuO{sub 2} product, containing around 3-11% w/w of the Pu-241 isotope, and placed into storage. During storage the Pu-241 isotope beta decays to Am-241 with a half-life of 14.4 years. {sub 94}{sup 241}Pu → (β 14.4 y) {sub 95}{sup 241}Am. This process has resulted in many 100 kgs of americium growing into the civil plutonium stockpile in the UK; material that is of value in generating heat sources and is able to be recycled. The key benefit of Am-241 as a potential European RPS source isotope is the availability of feed material along with the facilities to process it. It is expected that aged civil PuO{sub 2} will contain 25-50 g Am-241 per kg PuO{sub 2} depending on the source. A conceptual flowsheet using facilities for separating americium from plutonium is expected to produce on average 8.4 kg Am/year. ESA are now following their published road-map of studies to develop flight ready RTGs and RHUs. This has included the development and testing of the flowsheet to be used for production of Am-241. The project has focused on underpinning the conceptual flowsheet, using aged plutonium in NNL's PuMA laboratory. This has underpinned the design of a plant to produce a steady supply of Am-241. The scope of the overall project is 'store to store' - the starting point is aged plutonium currently housed in existing Sellafield stores and the end point is the storage of separated plutonium and americium powders on the Sellafield site. The full scale process is planned to be housed within the NNL's Central Laboratory in an existing facility designed for plutonium active operations. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tomographic inversion techniques incorporating physical constraints for line integrated spectroscopy in stellarators and tokamaks

Accurate tomographic inversion is important for diagnostic systems on stellarators and tokamaks which rely on measurements of line integrated emission spectra. A tomographic inversion technique based on spline optimization with enforcement of constraints is described that can produce unique and physically relevant inversions even in situations with noisy or incomplete input data. This inversion technique is routinely used in the analysis of data from the x-ray imaging crystal spectrometer (XICS) installed at the Large Helical Device. The XICS diagnostic records a 1D image of line integrated emission spectra from impurities in the plasma. Through the use of Doppler spectroscopy and tomographic inversion, XICS can provide profile measurements of the local emissivity, temperature, and plasma flow. Tomographic inversion requires the assumption that these measured quantities are flux surface functions, and that a known plasma equilibrium reconstruction is available. In the case of low signal levels or partial spatial coverage of the plasma cross-section, standard inversion techniques utilizing matrix inversion and linear-regularization often cannot produce unique and physically relevant solutions. The addition of physical constraints, such as parameter ranges, derivative directions, and boundary conditions, allow for unique solutions to be reliably found. The constrained inversion technique described here utilizes a modified Levenberg-Marquardt optimization scheme, which introduces a condition avoidance mechanism by selective reduction of search directions. The constrained inversion technique also allows for the addition of more complicated parameter dependencies, for example, geometrical dependence of the emissivity due to asymmetries in the plasma density arising from fast rotation. The accuracy of this constrained inversion technique is discussed, with an emphasis on its applicability to systems with limited plasma coverage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of future particle accelerators: issues and mitigations

The ever increasing demands placed upon machine performance have resulted in the need for more comprehensive particle accelerator modeling. Computer simulations are key to the success of particle accelerators. Many aspects of particle accelerators rely on computer modeling at some point, sometimes requiring complex simulation tools and massively parallel supercomputing. Examples include the modeling of beams at extreme intensities and densities (toward the quantum degeneracy limit), and with ultra-fine control (down to the level of individual particles). In the future, adaptively tuned models might also be relied upon to provide beam measurements beyond the resolution of existing diagnostics. Much time and effort has been put into creating accelerator software tools, some of which are highly successful. However, there are also shortcomings such as the general inability of existing software to be easily modified to meet changing simulation needs. In this paper possible mitigating strategies are discussed for issues faced by the accelerator community as it endeavors to produce better and more comprehensive modeling tools. This includes lack of coordination between code developers, lack of standards to make codes portable and/or reusable, lack of documentation, among others.

43 PARTICLE ACCELERATORS↗

Cosmic Shielding Studies at MicroBooNE

MicroBooNE, a 89 ton active volume liquid argon time projection chamber (LArTPC) located on the Fermilab’s Booster Neutrino Beamline, is designed to both probe neutrino physics phenomena, and further the development of LArTPC detector technology and event reconstruction. Since MicroBooNE is located only a few meters below the ground level, without significant shielding, a large flux of cosmic rays are expected to enter the detector volume. We present detailed simulation studies performed in order to quantify cosmogenic event rates in MicroBooNE. One of the most effective ways to reduce the cosmic air shower background is to use a high-density shielding material a few meters above the detector to block or attenuate the incoming cosmic particles. The effect of such an overburden on MicroBooNE backgrounds and event rates is explored and quantified using detailed simulation studies. In particular, the effect of a 3 m concrete overburden on these backgrounds is studied in detail. Special focus is given to cosmogenic electromagnetic showers that can fake an electron-like or photon-like event and pose a serious challenge to studies involving single $e/γ$ searches which form a primary physics goal of MicroBooNE. We find that the addition of a 3 m concrete overburden can help significantly reduce difficult-to-control backgrounds which arise from non-muon cosmic ray primaries.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Risk of theft and malicious use of radiation sources in transit

Remote radioactive source applications require frequent transportation of sources from storage locations to remote sites. This introduces risk of theft of a source during the transportation process, with the level of risk proportional to the radioactivity of the source. To that end, theft of smaller sources, such as microcurie-level moisture density gauges, are of minor concern, but larger sources, such as those used for radiography and well logging, present more risk. Radiography sources include 192 Ir, 75 Se, or 60 Co radionuclides with radioactivity amounts at or exceeding IAEA Category 2. Well-logging sources, primarily 241 Am/Be, are used for their neutron-emission properties. 137 Cs is also used in well-logging at lower activities than in radiography but at levels that still present some risk. The vulnerability for malicious use of such sources to cause contamination and associated economic effects is dependent on the elemental chemical and physical properties, especially melting point and bulk modulus. Theft of radiography sources is somewhat common, well-logging sources less so. Theft of sources commonly occurs in concert with theft of the vehicle, with the source subsequently abandoned. There have been some instances where a source appears to have been specifically targeted. There are a variety of security measures and protocols, available and under development, to mitigate the risk of theft and assist in source recovery.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Robe Development for Electrical Conductivity Analysis in an Electron Gun Produced Helium Plasma

The use of magnetohydrodynamic (MHD) power conversion systems, potentially coupled with a fission power source, is currently being investigated as a driver for an advanced propulsion system, such as a plasma thruster. The efficiency of a MHD generator is strongly dependent on the electrical conductivity of the fluid that passes through the generator; power density increases as fluid conductivity increases. Although traditional MHD flows depend on thermal ionization to enhance the electrical conductivity, ionization due to nuclear interactions may achieve a comparable or improved conductivity enhancement while avoiding many of the limitations inherent to thermal ionization. Calculations suggest that nuclear-enhanced electrical conductivity increases as the neutron flux increases; conductivity of pure He-3 greater than 10 mho/m may be achievable if exposed to a flux greater than 10(exp 12) neutrons/cm2/s.) However, this remains to be demonstrated experimentally. An experimental facility has been constructed at the Propulsion Research Center at the NASA Marshall Space Flight Center, using helium as the test fluid. High energy electrons will be used to simulate the effects of neutron-induced ionization of helium gas to produce a plasma. These experiments will be focused on diagnosis of the plasma in a virtually static system; results will be applied to future tests with a MHD system. Initial experiments will utilize a 50 keV electron gun that can operate at up to a current of 200 micro A. Spreading the electron beam over a four inch diameter window results in an electron flux of 1.5x 10(exp 13) e/sq cm/s. The equivalent neutron flux that would produce the same ionization fraction in helium is 1x10(exp 12) n/sq cm/s. Experiments will simulate the neutron generated plasma modeled by Bitteker, which takes into account the products of thermal neutron absorption in He-3, and includes various ion species in estimating the conductivity of the resulting plasma. Several different probes will be designed and implemented to verify the plasma kinetics model. System parameters and estimated operating ranges are summarized. The predicted ionization fraction, electron density, and conductivity levels are provided in for an equivalent neutron flux of 1x10(exp 12) n/cm2/s. Understanding the complex plasma kinetics throughout a MHD channel is necessary to design an optimal power conversion system for space propulsion applications. The proposed experiments seek to fully characterize the helium plasma and to determine the reliability of each measurement technique, such that they may be applied to more advanced MHD studies. The expected value of each plasma parameter determined from theoretical models will be verified experimentally by several independent techniques to determine the most reliable method of obtaining each parameter. The results of these experiments will be presented in the final paper.

Bragg-Sitton, Shannon M.↗

Mechanical quantum sensing in the search for dark matter

Numerous astrophysical and cosmological observations are best explained by the existence of dark matter, a mass density which interacts only very weakly with visible, baryonic matter. Here, searching for the extremely weak signals produced by this dark matter strongly motivate the development of new, ultra-sensitive detector technologies. Paradigmatic advances in the control and readout of massive mechanical systems, in both the classical and quantum regimes, have enabled unprecedented levels of sensitivity. In this white paper, we outline recent ideas in the potential use of a range of solid-state mechanical sensing technologies to aid in the search for dark matter in a number of energy scales and with a variety of coupling mechanisms.

79 ASTRONOMY AND ASTROPHYSICS↗

Extreme Enhancement-Mode Operation Accumulation Channel Hydrogen-Terminated Diamond FETs with V th < -6 V and High on-Current

In this work, a new Field Effect Transistor device concept based on hydrogen-terminated diamond (H-diamond) is demonstrated that operates in an Accumulation Channel rather than a Transfer Doping regime. The FET devices demonstrate both extreme enhancement-mode operation and high on-current with improved channel charge mobility compared to Transfer-Doped equivalents. Electron-beam evaporated Al 2 O 3 is used on H-diamond to suppress the Transfer Doping mechanism and produce an extremely high ungated channel resistance. A high-quality H-diamond surface with an unpinned Fermi level is crucially achieved, allowing for the formation of a high-density hole accumulation layer by gating the entire device channel which is encapsulated in dual-stacks of Al 2 O 3 . Completed devices with gate/channel length of 1 µm demonstrate record threshold voltage < -6 V with on-current > 80 mA mm -1 . Carrier density and mobility figures extracted by CV analysis indicate a high 2D charge density of ≈ 2 × 10 12 cm -2 and increased hole mobility of 110 cm 2 V -1 s -1 in comparison with more traditional Transfer-Doped H-diamond FETs. These results demonstrate the most negative threshold voltage yet reported for H-diamond FETs and highlight a powerful new strategy to greatly improve carrier mobility and enable enhanced high power and high frequency diamond transistor performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The coincidence counting technique for orders of magnitude background reduction in data obtained with the magnetic recoil spectrometer at OMEGA and the NIF

A magnetic recoil spectrometer (MRS) has been built and successfully used at OMEGA for measurements of down-scattered neutrons (DS-n), from which an areal density in both warm-capsule and cryogenic-DT implosions have been inferred. Another MRS is currently being commissioned on the National Ignition Facility (NIF) for diagnosing low-yield tritium-hydrogen-deuterium implosions and high-yield DT implosions. As CR-39 detectors are used in the MRS, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). The coincidence counting technique was developed to reduce these types of background tracks to the required level for the DS-n measurements at OMEGA and the NIF. Using this technique, it has been demonstrated that the number of background tracks is reduced by a couple of orders of magnitude, which exceeds the requirement for the DS-n measurements at both facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discretized versus continuous models of p-wave interacting fermions in one dimension

We present a general mapping between continuous and lattice models of Bose and Fermi gases in one dimension, interacting via local two-body interactions. For s-wave interacting bosons we arrive at the Bose-Hubbard model in the weakly interacting, low-density regime. The dual problem of p-wave interacting fermions is mapped to the spin-1/2 XXZ model close to the critical point in the highly polarized regime. The mappings are shown to be optimal in the sense that they produce the least error possible for a given discretization length. As an application we examine the ground state of an interacting Fermi gas in a harmonic trap, calculating numerically real-space and momentum-space distributions as well as two-particle correlations. In the analytically known limits the convergence of the results of the lattice model with the continuous one is shown.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗