Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multiplex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Sunyaev-Zel'Dovich effect observations of the bullet cluster (1E 0657-56) with APEX-SZ

We present observations of the Sunyaev-Zel'dovich effect (SZE) in the Bullet cluster (1E 0657-56) using the APEX-SZ instrument at 150 GHz with a resolution of 1'. The main results are maps of the SZE in this massive, merging galaxy cluster. The cluster is detected with 23 sigma significance within the central 1' radius of the source position. The SZE map has a broadly similar morphology to that in existing X-ray maps of this system, and we find no evidence for significant contamination of the SZE emission by radio or IR sources. In order to make simple quantitative comparisons with cluster gas models derived from X-ray observations, we fit our data to an isothermal elliptical beta model, despite the inadequacy of such a model for this complex merging system. With an X-ray derived prior on the power-law index, beta = 1.04+0.16-0.10, we find a core radius rc = 142" +- 18", an axial ratio of 0.889 +- 0.072, and a central temperature decrement of -771 +- 71 muKCMB, including a +-5.5percent flux calibration uncertainty. Combining the APEX-SZ map with a map of projected electron surface density from Chandra X-ray observations, we determine the mass-weighted temperature of the cluster gas to be Tmg = 10.8 +- 0.9 keV, significantly lower than some previously reported X-ray spectroscopic temperatures. Under the assumption of an isothermal cluster gas distribution in hydrostatic equilibrium, we compute the gas mass fraction for prolate and oblate spheroidal geometries and find it to be consistent with previous results from X-ray and weak-lensing observations. This work is the first result from the APEX-SZ experiment and represents the first reported scientific result from observations with a large array of multiplexed superconducting transition-edge sensor bolometers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-Time Spatio-Temporal Twice Whitening for MIMO Energy Detector

While many techniques exist for local spectrum sensing of a primary user, each represents a computationally demanding task to secondary user receivers. In software-defined radio, computational complexity lengthens the time for a cognitive radio to recognize changes in the transmission environment. This complexity is even more significant for spatially multiplexed receivers, e.g., in SIMO and MIMO, where the spatio-temporal data sets grow in size with the number of antennae. Limits on power and space for the processor hardware further constrain SDR performance. In this report, we discuss improvements in spatio-temporal twice whitening (STTW) for real-time local spectrum sensing by demonstrating a form of STTW well suited for MIMO environments. We implement STTW on the Coherent Logix hx3100 processor, a multicore processor intended for low-power, high-throughput software-defined signal processing. These results demonstrate how coupling the novel capabilities of emerging multicore processors with algorithmic advances can enable real-time, software-defined processing of large spatio-temporal data sets.

97 MATHEMATICS AND COMPUTING↗

Reaction of the C2H radical with 1-butyne (C4H6): Low Temperature Kinetics and Isomer-Specific Product Detection

The rate coefficient for the reaction of the ethynyl radical (C{sub 2}H) with 1-butyne (H-C{triple_bond}C-CH{sub 2}-CH{sub 3}) is measured in a pulsed Laval nozzle apparatus. Ethynyl radicals are formed by laser photolysis of acetylene (C{sub 2}H{sub 2}) at 193 nm and detected via chemiluminescence (C{sub 2}H + O{sub 2} {yields} CH (A{sup 2}{Delta}) + CO{sub 2}). The rate coefficients are measured over the temperature range of 74-295 K. The C{sub 2}H + 1-butyne reaction exhibits no barrier and occurs with rate constants close to the collision limit. The temperature dependent rate coefficients can be fit within experimental uncertainties by the expression k = (2.4 {+-} 0.5) x 10{sup -10} (T/295 K)-(0.04 {+-} 0.03) cm{sup 3} molecule{sup -1}s{sup -1}. Reaction products are detected at room temperature (295 K) and 533 Pa using a Multiplexed Photoionization Mass Spectrometer (MPIMS) coupled to the tunable VUV synchrotron radiation from the Advanced Light Source at the Lawrence Berkeley National Laboratory. Two product channels are identified for this reaction: m/z = 64 (C{sub 5}H{sub 4}) and m/z = 78 (C{sub 6}H{sub 6}) corresponding to the CH{sub 3}- and H-loss channels, respectively. Photoionization efficiency (PIE) curves are used to analyze the isomeric composition of both product channels. The C{sub 5}H{sub 4} products are found to be exclusively linear isomers composed of ethynylallene and methyldiacetylene in a 4:1 ratio. In contrast, the C{sub 6}H{sub 6} product channel includes two cyclic isomers, fulvene 18({+-}5)% and 3,4-dimethylenecyclobut-1-ene 32({+-}8)%, as well as three linear isomers, 2-ethynyl-1,3-butadiene 8({+-}5)%, 3,4-hexadiene-1-yne 28({+-}8)% and 1,3-hexadiyne 14({+-}5)%. Within experimental uncertainties, we do not see appreciable amounts of benzene and an upper limit of 10% is estimated. Diacetylene (C{sub 4}H{sub 2}) formation via the C{sub 2}H{sub 5}-loss channel is also thermodynamically possible but cannot be observed due to experimental limitations. The implications of these results for modeling of planetary atmospheres, especially of Saturn's largest moon Titan, are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum dot conjugates in a sub-micrometer fluidic channel

A nanofluidic channel fabricated in fused silica with an approximately 500 nm square cross section was used to isolate, detect and identify individual quantum dot conjugates. The channel enables the rapid detection of every fluorescent entity in solution. A laser of selected wavelength was used to excite multiple species of quantum dots and organic molecules, and the emission spectra were resolved without significant signal rejection. Quantum dots were then conjugated with organic molecules and detected to demonstrate efficient multicolor detection. PCH was used to analyze coincident detection and to characterize the degree of binding. The use of a small fluidic channel to detect quantum dots as fluorescent labels was shown to be an efficient technique for multiplexed single molecule studies. Detection of single molecule binding events has a variety of applications including high throughput immunoassays.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

ElectroNeedle Biological Sensor Array

A device that when pressed against the skin can make rapid, multiplexed diagnostic measurements in a point-of-care setting. 2007 R&D 100 winner (SAND2007-1053P)

59 BASIC BIOLOGICAL SCIENCES↗

ElectroNeedle Biological Sensor Array

A device that when pressed against the skin can make rapid, multiplexed diagnostic measurements in a point-of-care setting. 2007 R&D 100 winner (SAND2007-1053P)

59 BASIC BIOLOGICAL SCIENCES↗

Early Events in Ionic Liquid Radiation Chemistry

Ionic liquids are interesting and useful materials whose solvation time scales are up to thousands of times longer than in conventional solvents. The extended lifetimes of pre-solvated electrons and other energetic species in ionic liquids has profound consequences for the radiolytic product distributions and reactivity patterns. We use a newly developed, multiplexed variation of pulse-probe spectroscopy to measure the kinetics of the early dynamical and reactive events in ionic liquids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploiting silicon chip technology for control of electrons on superfluid helium.

Electrons on the surface of superfluid helium have extremely high mobilities and long predicted spin coherence times, making them ideal mobile qubits. Previous work has shown that electrons localized in helium filled channels can be reliably transported between multiple underlying gates. Silicon chips have been designed, fabricated, and post processed by reactive ion etching to leverage the large scale integration capabilities of silicon technology. These chips, which serve as substrates for the electrons on helium research, utilize silicon CMOS for on-chip signal amplification and multiplexing and the uppermost metal layers for defining the helium channels and applying electrical potentials for moving the electrons. We will discuss experimental results for on-chip circuitry and clocked electron transport along etched channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Operational status of the Los Alamos neutron science center (LANSCE)

The Los Alamos Neutron Science Center (LANSCE) accelerator and beam delivery complex generates the proton beams that serve three neutron production sources; the thermal and cold source for the Manuel Lujan Jr. Neutron Scattering Center, the Weapons Neutron Research (WNR) high-energy neutron source, and a pulsed Ultra-Cold Neutron Source. These three sources are the foundation of strong and productive multi-disciplinary research programs that serve a diverse and robust user community. The facility also provides multiplexed beams for the production of medical radioisotopes and proton radiography of dynamic events. The recent operating history of these sources will be reviewed and plans for performance improvement will be discussed, together with the underlying drivers for the proposed LANSCE Refurbishment project. The details of this latter project are presented in a separate contribution.

42 ENGINEERING↗

Improved Frequency-Domain Steady-State Modeling of the Dual-Active-Bridge Converter Considering Finite ZVS Transition Time Effects

This article presents an improved analytical modeling (IAM) approach for the dual-active-bridge (DAB) converter in the frequency-domain. Specifically, finite transition times are incorporated into the improved modeling that are significant in DAB converters operated at high frequency. The IAM approach is first motivated by comparing traditional frequency-domain modeling against realistic simulation results in LTspice. Next, the IAM approach is mathematically developed in an iterative fashion, where the conventional frequency-domain approach is used as the initialization of the operational behavior of the converter. Subsequent iterations of the IAM algorithm incorporate finite rise- and falltimes of device output capacitances based on detailed switching behavior analyses, which may considerably perturb the desired modulation parameters (i.e., phase shift and zero states). While the initially proposed IAM approach demonstrates advantages over ideal modeling, it is still shown to exhibit errors when applied to device transitions with significant nonlinearity in parasitic output capacitance. To account for this, a three-slope approximation to the switching transition is then motivated and developed, which enables significantly improved steady-state prediction accuracy. Simulation and experimental results confirm unacceptable inaccuracies associated with the conventional frequency-domain modeling across a wide range of operating conditions, alongside enhanced accuracy provided by the proposed modeling approach.

14 SOLAR ENERGY↗

Direct Experimental Observation of the Tetrabromine Cluster Br 4 by Synchrotron Photoionization Mass Spectrometry

We present a first spectroscopic characterization of the homoatomic polyhalogen tetrabromine, Br 4 , in the gas phase. Photolysis of CHBr 3 at 248 nm is used to generate atomic bromine radicals in a flow tube reactor. Resulting combination products are detected by photoionization mass spectrometry at the Advanced Light Source of the Lawrence Berkeley National Laboratory. Interpretation of the experimental mass spectra is informed by calculated adiabatic ionization energies carried out at the CCSD(T)/aug-cc-pVTZ//M06-2X/aug-cc-pVTZ and CCSD(T)/aug-cc-pVTZ//cam-B3LYP/6-311++g** levels of theory. Tunable VUV synchrotron radiation enables the collection of the mass-selected photoionization spectra by which Br 4 is assigned using Franck-Condon simulations of a Br 2 dimer with a stretched tetrahedral geometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bioelectrochemical crossbar architecture screening platform for extracellular electron transfer

Electroactive microbes can serve as living components in bioelectronic devices, where their unique ability to transfer electrons enables applications in sensing, energy conversion, and synthesis, but they remain challenging to engineer because the bioelectrochemical systems (BESs) used for characterization are low throughput. Here, we present a bioelectrochemical crossbar architecture screening platform (BiCASP) that uses stacked and orthogonally arrayed electrodes to enable individual sample selection for characterization in arrayed formats. This device reports on the current generated by electroactive bacteria on the minute timescale, decreasing the time for data acquisition by several orders of magnitude compared to conventional BESs. This device increases the throughput of screening engineered biological components in cells, identifying mutants of the membrane protein wire MtrA in Shewanella oneidensis that retain the ability to support extracellular electron transfer (EET). BiCASP may be integrated with bioelectronics that need directed evolution of electroactive proteins.

Shewanella↗

Hybrid classical-quantum communication networks

Over the past several decades, the proliferation of global classical communication networks has transformed various facets of human society. Concurrently, quantum networking has emerged as a dynamic field of research, driven by its potential applications in distributed quantum computing, quantum sensor networks, and secure communications. This prompts a fundamental question: rather than constructing quantum networks from scratch, can we harness the widely available classical fiber-optic infrastructure to establish hybrid quantum–classical networks? This paper aims to provide a comprehensive review of ongoing research endeavors aimed at integrating quantum communication protocols, such as quantum key distribution, into existing lightwave networks. This approach offers the substantial advantage of reducing implementation costs by allowing classical and quantum communication protocols to share optical fibers, communication hardware, and other network control resources—arguably the most pragmatic solution in the near term. In the long run, classical communication will also reap the rewards of innovative quantum communication technologies, such as quantum memories and repeaters. Accordingly, our vision for the future of the Internet is that of heterogeneous communication networks thoughtfully designed for the seamless support of both classical and quantum communications.

Fiber-optic communication↗

Differential structure and functional gene response to geochemistry associated with the suspended and attached shallow aquifer microbiomes from the Illinois Basin, IL

Despite the clear ecological significance of the microbiomes inhabiting groundwater and connected ecosystems, our current understanding of their habitats, functionality, and the ecological processes controlling their assembly have been limited. In this study, an efficient pipeline combining geochemistry, high-throughput Fluidigm TM functional gene amplification and sequencing was developed to analyze the suspended and attached microbial communities inhabiting five groundwater monitoring wells in the Illinois Basin, USA. The dominant taxa in the suspended and the attached microbial communities exhibited significantly different spatial and temporal changes in both alpha- and beta-diversity. Further analyses of representative functional genes affiliated with N 2 fixation (nifH), methane oxidation (pmoA), and sulfate reduction (dsrB, and aprA), suggested functional redundancy within the shallow aquifer microbiomes. While more diversified functional gene taxa were observed for the suspended microbial communities than the attached ones except for pmoA, different levels of changes over time and space were observed between these functional genes. Notably, deterministic and stochastic ecological processes shaped the assembly of microbial communities and functional gene reservoirs differently. While homogenous selection was the prevailing process controlling assembly of microbial communities, the neutral processes (e.g., dispersal limitation, drift and others) were more important for the functional genes. The results suggest complex and changing shallow aquifer microbiomes, whose functionality and assembly vary even between the spatially proximate habitats and fractions. As a result, this research underscored the importance to include all the interface components for a more holistic understanding of the biogeochemical processes in aquifer ecosystems, which is also instructive for practical applications.

54 ENVIRONMENTAL SCIENCES↗

A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca 2+ and pH

Homeostasis of ionized calcium in biofluids is critical for human biological functions and organ systems. Measurement of ionized calcium for clinical applications is not easily accessible due to its strict procedures and dependence on pH. pH balance in body fluids greatly affects metabolic reactions and biological transport systems. Here, we demonstrate a wearable electrochemical device for continuous monitoring of ionized calcium and pH of body fluids using a disposable and flexible array of Ca 2+ and pH sensors that interfaces with a flexible printed circuit board. This platform enables real-time quantitative analysis of these sensing elements in body fluids such as sweat, urine, and tears. Accuracy of Ca 2+ concentration and pH measured by the wearable sensors is validated through inductively coupled plasma-mass spectrometry technique and a commercial pH meter, respectively. Our results show that the wearable sensors have high repeatability and selectivity to the target ions. Real-time on-body assessment of sweat is also performed, and our results indicate that calcium concentration increases with decreasing pH. Finally, this platform can be used in noninvasive continuous analysis of ionized calcium and pH in body fluids for disease diagnosis such as primary hyperparathyroidism and kidney stones.

47 OTHER INSTRUMENTATION↗

Roll-to-Roll Gravure Printed Electrochemical Sensors for Wearable and Medical Devices

As recent developments in noninvasive biosensors spearhead the thrust toward personalized health and fitness monitoring, there is a need for high throughput, cost-effective fabrication of flexible sensing components. Toward this goal, in this paper we present roll-to-roll (R2R) gravure printed electrodes that are robust under a range of electrochemical sensing applications. We use inks and electrode morphologies designed for electrochemical and mechanical stability, achieving devices with uniform redox kinetics printed on 150 m flexible substrate rolls. We show that these electrodes can be functionalized into consistently high performing sensors for detecting ions, metabolites, heavy metals, and other small molecules in noninvasively accessed biofluids, including sensors for real-time, in situ perspiration monitoring during exercise. This development of robust and versatile R2R gravure printed electrodes represents a key translational step in enabling large-scale, low-cost fabrication of disposable wearable sensors for personalized health monitoring applications.

42 ENGINEERING↗

A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis

Wearable sweat sensing is a rapidly rising research area driven by its promising potential in health, fitness, and diagnostic applications. Despite the growth in the field, major challenges in relation to sweat metrics remain to be addressed. These challenges include sweat rate monitoring for its complex relation with sweat compositions and sweat sampling for sweat dynamics studies. Here, we present a flexible microfluidic sweat sensing patch that enhances real-time electrochemical sensing and sweat rate analysis via sweat sampling. The device contains a spiral-patterned microfluidic component that is embedded with ion-selective sensors and an electrical impedance-based sweat rate sensor on a flexible plastic substrate. The patch is enabled to autonomously perform sweat analysis by interfacing the sensing component with a printed circuit board that is capable of on-site signal conditioning, analysis, and transmission. Progressive sweat flow in the microfluidic device, governed by the pressure induced by the secreted sweat, enhances sweat sampling and electrochemical detection via a defined sweat collection chamber and a directed sweat route. The characteristic of the sweat rate sensor is validated through a theoretical simulation, and the precision and accuracy of the flow rate is verified with a commercial syringe pump and a Macroduct sweat collector. On-body simultaneous monitoring of ion (H + , Na + , K + , Cl – ) concentration and sweat rate is also demonstrated for sensor functionality. This sweat sensing patch provides an integrated platform for a comprehensive sweat secretion analysis and facilitates physiological and clinical investigations by closely monitoring interrelated sweat parameters.

47 OTHER INSTRUMENTATION↗

Investigation of 2D photonic crystal structure based channel drop filter using quad shaped photonic crystal ring resonator for CWDM system

In this paper, the design & performance of two dimensional (2-D) photonic crystal structure based channel drop filter is investigated using quad shaped photonic crystal ring resonator. In this paper, Photonic Crystal (PhC) based on square lattice periodic arrays of Gallium Indium Phosphide (GaInP) rods in air structure have been investigated using Finite Difference Time Domain (FDTD) method and photonic band gap is being calculated using Plane Wave Expansion (PWE) method. The PhC designs have been optimized for telecommunication wavelength λ= 1571 nm by varying the rods lattice constant. The number of rods in Z and X directions is 21 and 20, with lattice constant 0.540 nm it illustrates that the arrangement of Gallium Indium Phosphide (GaInP) rods in the structure which gives the overall size of the device around 11.4 µm × 10.8 µm. The designed filter gives good dropping efficiency using 3.298, refractive index. The designed structure is useful for CWDM systems. This device may serve as a key component in photonic integrated circuits. The device is ultra compact with the overall size around 123 µm{sup 2}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗