Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Measurements of supersonic jet aircraft wakes in the stratosphere

Progress is reported in an experimental program consisting of making supersonic aircraft wakes visible in the stratosphere so that photographs can be taken which yield wake dimensions vs time, and so that aircraft equipped with instruments which measure key exhaust species can find and penetrate the wakes. The object is to provide verification of fluid dynamic and chemical models. Three available models are summarized, and the experimental methods used are described. The Lockheed model predictions correspond in general most closely to experimental wake cross-sectional aerea. NO data are in reasonable agreement with NO predictions, but chemical models are relatively undeveloped, and additional measurements of exhaust products are needed before verification of chemical models becomes possible. However, the overall feasibility of wake visualization for model verification is substantiated. It is emphasized that significant model differences exist that must be resolved before reliable predictions can be made in the wake regimes studied.

Farlow, N. H.↗

The Development and Deployment of a Ground-Based, Laser-Induced Fluorescence Instrument for the In Situ Detection of Iodine Monoxide Radicals

High abundances of iodine monoxide (IO) are known to exist and to participate in local photochemistry of the marine boundary layer. Of particular interest are the roles IO plays in the formation of new particles in coastal marine environments and in depletion episodes of ozone and mercury in the Arctic polar spring. This paper describes a ground-based instrument that measures IO at mixing ratios less than one part in 1012. The IO radical is measured by detecting laser-induced fluorescence at wavelengths longer that 500 nm. Tunable visible light is used to pump the A23/2 (v = 2) ← X23/2 (v = 0) transition of IO near 445 nm. The laser light is produced by a solid-state, Nd:YAG-pumped Ti:Sapphire laser at 5 kHz repetition rate. The laser-induced fluorescence instrument performs reliably with very high signal-to-noise ratios (>10) achieved in short integration times (<1 min). The observations from a validation deployment to the Shoals Marine Lab on Appledore Island, ME are presented and are broadly consistent with in situ observations from European Coastal Sites. Mixing ratios ranged from the instrumental detection limit (<1 pptv) to 10 pptv. These data represent the first in situ point measurements of IO in North America.

marine boundary layer↗

Estimation of total ozone from satellite measurements of backscattered ultraviolet earth radiance.

Total ozone is estimated from Nimbus IV satellite measurements of the attenuation of backscattered radiances at wavelengths between 3100 and 3400 A. A measurement of the backscattered radiance at 3800 A, outside the ozone absorption band, is used to determine an equivalent Lambert albedo for the cloud-ground-haze surface viewed by the instrument. The measured relative attenuation at two wavelengths is compared with such values precomputed for a series of standard ozone profiles and corrected for the equivalent Lambert albedo. Total ozone is obtained by interpolation. Two alternative methods are used to assign an equivalent Lambert albedo at the absorbing wavelengths. Total ozone values estimated by these methods are compared with the Dobson (ground-truth) data by linear regression. The available evidence suggests that the true standard error of the satellite data may be 0.015 atm-cm or less for solar zenith angles smaller than 60 deg.

Mateer, C. L.↗

The Giotto three-dimensional positive ion analyser

An instrument to measure the three-dimensional energy distribution of positive ions in order to study the interaction between the solar wind and ionized Halley cometary particles was designed. Two sensors measure the distribution from 10 eV to 20 keV once per spacecraft spin and the distribution from 90 eV to 90 keV, with coarse mass discrimination, once every 32 spins. The instrument was turned on September 8, 1985. The performance throughout all testing was nominal. The spacecraft was greater than 10 million km from the earth in the solar wind. The only population identified is the solar wind. The Fast Ion Sensor follows solar wind variations with its autoranging capability. The Implanted Ion Sensor identifies higher mass ions such as O(6+) and O(5+) in the solar wind.

Johnstone, A. D.↗

A suggested method for measuring turbulence

The desirability of a quantitative measure of turbulence is emphasized, and a possible method of attack on the problem is discussed. Data are presented to show that the hot-wire anemometer has possibilities as an instrument for measuring turbulence. An apparatus consisting essentially of two hot wire, one parallel to the air flow and one at right angles to it, is suggested.

Taylor, Fayette C↗

Improved Devices for Collecting Sweat for Chemical Analysis

Improved devices have been proposed for collecting sweat for biochemical analysis especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca2+ and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca2+ content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca2+ content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available to other analytical instruments for measuring concentrations of substances other than Ca2+.

Feeback, Daniel L.↗

Analysis of the Amplitude Response of a Two-Point and a Two-Line/Multi-Point Focused Laser Differential Interferometer

Experiments were performed with two different focused laser differential interferometer (FLDI) instruments to assess the amplitude response of each instrument to a traveling shock-wave generated by a laser spark. The first FLDI instrument generated two measurement points, with each measurement point providing sensitivity to density fluctuations induced by the shockwave. By performing a cross-correlation between the signals obtained from each measurement point, the phase velocity of density fluctuations can be obtained. The second FLDI instrument generated two measurement lines that are oriented either parallel or orthogonal to the shockwave direction of travel with the resulting interference pattern sampled at multiple equally-spaced points along each line. As a result, this instrument provides density fluctuation measurement capability at multiple points simultaneously. When the measurement lines are oriented parallel to the shockwave direction of travel, the phase velocity, rate of change of the phase velocity, and acceleration of density fluctuations traveling along each line can be obtained by performing a cross-correlation between points along a single line. When the measurement lines are oriented orthogonal to the shockwave direction of travel, the spatially-varying phase velocity can be obtained by performing a cross-correlation between points at the same relative location on each measurement line. Computations of the shockwave generated by the laser spark are used to simulate the response of each instrument and are compared to the experimental results. High-speed Schlieren imaging has also been performed and is compared with the FLDI measurements and computational results.

Focused Laser Differential Interferometer↗

Improved Devices for Collecting Sweat for Chemical Analysis

Improved devices have been proposed for collecting sweat for biochemical analysis - especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca(2+) and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca(2+) content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca(2+) content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available to other analytical instruments for measuring concentrations of substances other than Ca(2+).

Feedback, Daniel L.↗

The FIELDS Instrument Suite for Solar Probe Plus Measuring the Coronal Plasma and Magnetic Field, Plasma Waves and Turbulence, and Radio Signatures of Solar Transients

NASA's Solar Probe Plus (SPP) mission will make the first in situ measurements of the solar corona and the birthplace of the solar wind. The FIELDS instrument suite on SPP will make direct measurements of electric and magnetic fields, the properties of in situ plasma waves, electron density and temperature profiles, and interplanetary radio emissions, amongst other things. Here, we describe the scientific objectives targeted by the SPP/FIELDS instrument, the instrument design itself, and the instrument concept of operations and planned data products.

Solar Probe Plus↗

Conversions to the Lidar Atmospheric Sensing Experiment (LASE) Instrument for Nadir and Zenith Measurements

LASE now has the advantage of being economically upgraded and customized with COTS hardware and software while using "C" software language. These changes are made so as not to destroy the form, fit and functional characteristics required for flights aboard the ER-2 aircraft. The LASE Instrument can now be quickly adapted to fly onboard ER-2, P-3, C-130 and DC-8 aircraft. The adaptability of the CDS upgraded electronics compliments other modular subsystems like the laser optical bench in that it was designed to be a test bed for new technology lasers.

Moore, Alvah S., Jr.↗

Observations Show Charge Density of Volcanic Plumes is Higher Than Thunderstorms

We analyze slow electric field change and lightning mapping measurements to provide insight into the characteristics of volcanic lightning and the associated implications on charging processes and the charge structure of a Vulcanian eruption plume. Data were obtained during a multi-instrumental field campaign at Sakurajima volcano in 2015 when the Showa crater was active. We combine the electric field change and lightning mapping data from one explosive eruption on June 6, 2015 to identify individual flashes. From this, we interpret the flash type and polarity. In addition, the long-time constant of the electric field change instrument allowed measurement of the quasi-static field associated with charge separation in the eruption plume. We find that both intracloud and cloud-to-ground discharges occurred, and the polarity of cloud-to-ground discharges were all negative. The quasi-static field measurement showed the plume carried a net negative charge. We calculate both the total charge transferred by cloud-to-ground discharges and the net charge density of the eruption plume. We find that cloud-to-ground discharges transfer an average of –0.41C per flash and the net charge density was –33C/ km 3 . Here, the percent error is at least 200%, due to uncertainty in the antenna gain. We show that these estimates are consistent with lightning that is 100 m in length. Further, the average flash rate during the first 8 s following the onset of eruption was five flashes per second. After that time, the flash rate abruptly decreased, which may be related to the end of gas-thrust forcing.

58 GEOSCIENCES↗

Solar meter with silicon photocell

Instrument for measuring light falling on given spot uses simple silicon photovoltaic cell as sensing element. It measures all light at location: direct, scattered, reflected, or reradiated. Silicon cell is coated with thick antireflecting layer of silicon monoxide and is enclosed in glass dome. Large heat sink reduces temperature fluctuations. Instrument is accurate within few percentage points over angle of Sun's arc across sky.

Yanow, G.↗

Application of in-flight thrust determination uncertainty

A numerical example is given of a previously proposed methodology for the evaluation of in-flight thrust measurement uncertainty, using data extracted from a performance report comparing two different missile prototypes under a variety of flight conditions. Attention is given to the data for the AGM-68B Air Launched Cruise Missile, which is powered by the F107 dual-spool, mixed flow turbofan engine. Assessments are made of the definition of the measurement process, instrumentation error estimation, the propagation of errors to thrust calculation, mathematical model errors, the in-flight thrust error component, and correction to standard conditions. It is concluded that in-flight thrust measurement uncertainty limits can be evaluated from measurement system error analysis results and test data for the missile evaluation process presently described.

Adams, G. R.↗

Measured unsteady transonic aerodynamic characteristics of an elastic supercritical wing with an oscillating control surface

Transonic steady and unsteady aerodynamic data were measured on a large elastic wing in the NASA Langley Transonic Dynamics Tunnel. The wing had a supercritical airfoil shape and a leading-edge sweepback of 28.8 deg. The wing was heavily instrumented to measure both static and dynamic pressures and deflections. A hydraulically driven outboard control surface was oscillated to generate unsteady airloads on the wing. Representative results from the wind tunnel tests are presented and discussed, and the unexpected occurrence of an unusual dynamic wing instability, which was sensitive to angle of attack, is reported.

Seidel, D. A.↗

Measured unsteady transonic aerodynamic characteristics of an elastic supercritical wing with an oscillating control surface

Transonic steady and unsteady aerodynamic data were measured on a large elastic wing in the NASA Langley Transonic Dynamics Tunnel. The wing had a supercritical airfoil shape and a leading-edge sweepback of 28.8 deg. The wing was heavily instrumented to measure both static and dynamic pressures and deflections. A hydraulically driven outboard control surface was oscillated to generate unsteady airloads on the wing. Representative results from the wind tunnel tests are presented and discussed, and the unexpected occurrence of an unusual dynamic wing instability, which was sensitive to angle of attack, is reported.

Seidel, D. A.↗

Lunar Atmosphere and Dust Environment Explorer Integration and Test

The Lunar Atmosphere and Dust Environment Explorer (LADEE) is a NASA collaborative flight project to explore the lunar exosphere. It is being developed through a unique partnership between NASA's Ames Research Center (ARC) and Goddard Space Flight Center (GSFC). Each center brings its own experience and flight systems heritage to the task of integrating and testing the LADEE subsystems, instruments, and spacecraft. As an "in-house" flight project being implemented at low-cost and moderate risk, LADEE relies on single-string subsystems and protoflight hardware to accomplish its mission. Integration and test (l&T) of the LADEE spacecraft with the instruments will be performed at GSFC, and includes assembly, integration, functional testing, and flight qualification and acceptance testing. Due to the nature of the LADEE mission, l&T requirements include strict contamination control measures and instrument calibration procedures. Environmental testing will include electromagnetic compatibility (EMC), vibro-acoustic testing, and thermal-balance/vacuum. Upon successful completion of spacecraft l&T, LADEE will be launched from NASA's Wallops Flight Facility. Launch of the LADEE spacecraft is currently scheduled for December 2012.

Wright, Michael R.↗

Flight experiments measuring boundary-layer disturbances in laminar flow and correlation with stability analysis

Flight test results are reported from an experiment designed to study the detailed growth of disturbances in the laminar boundary layer. A gloved wing section incorporating closely-spaced flush-mounted streamwise-located instrumentation for measuring instability frequencies and amplitude growths as well as pressure distributions was used. The growth of Tollmien-Schlichting (T-S) and crossflow instabilities is predicted by the linear e exp n method and compared to the measured boundary-layer disturbance frequencies. The predictions showed good agreement with the measured data. The results exhibited fair agreement with previous n(T-S) and n(CF) flight correlations for several of the conditions analyzed. It is inferred from the high n(T-S) values for these data that moderately swept wings at compressible speeds can withstand higher combinations of n(T-S) and n(CF) values and still remain laminar than previously thought.

Lee, Cynthia C.↗