Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROGRIDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Photovoltaics module reliability for the terawatt age

Photovoltaics (PV), or solar electricity generation, has become the cheapest form of energy in many locations worldwide and, combined with energy storage, has the potential to satisfy most of our electricity needs. PV has grown at an annual compounded growth rate of approximately 30% in the last three decades. Solar energy systems will continue their impressive growth in distributed energy, microgrids, and utility scale, as efforts are made for dependable electricity in an age with increasing extreme weather. However, within this remarkable success lies a new challenge. The growth curve, combined with rapid product innovation and scale up, means that the majority of PV systems are new, without the three years of performance data that have been required in the past to estimate product lifetime. PV reliability has to address this challenge. In this review we present a brief summary of PV reliability starting with brief historical synopsis, detailing some of the technological challenges and present a framework required for long lifetime.

14 SOLAR ENERGY↗

Resiliency of Distribution Systems Incorporating Asynchronous Information for System Restoration

Resiliency of distribution systems under extreme operating conditions is critical, especially when the utility is not available. With the large-scale deployment of distributed resources, it becomes possible to restore critical loads with local non-utility resources. Distribution system operators (DSOs) need to determine the critical loads to be restored, considering limited resources and distribution facilities. Several studies on resiliency have been conducted for the restoration of distribution systems. However, the inherent asynchronous characteristic on the information availability has not been incorporated. With incomplete and asynchronous information, decisions may be made that result in underutilization of generation resources. In this paper, a new distribution system restoration approach is proposed, considering uncertain devices and associated asynchronous information. It uses a two-module architecture that efficiently optimizes restoration actions using a binary linear programming model and evaluates their feasibility with unbalanced optimal power flow. Networked microgrids are included in the model. The IEEE 123-node test feeder is used for validation. Results show that asynchronous messages may affect the restoration actions significantly and the impacts can be mitigated by the proposed decision support tool for the DSOs.

Bedoya, Juan C.↗

Inverter Model Validation and Calibration Using Phasor Measurement Unit Data

As the penetration of inverter-based renewable energy resources increases in the power grid, especially at the distribution and microgrid levels, the need to accurately represent them in planning studies increases as well. However, due to the lack of well-established standard procedures, and vendor reluctance towards the detailed sharing of proprietary models, automated dynamic model validation and parameter calibration tools for inverter based resources (IBRs) remain scarce. This work presents a model validation and parameter calibration platform for representing IBRs with generic phasor-domain models. Phasor measurements of power system events are used for continuous validation using the data playback method, and model parameters are re-calibrated if a significant mismatch between measurements and model response is observed. Unique features of the proposed platform include- (a) an iterative Bayesian optimization approach towards parameter calibration to address a possible mismatch between the structures of generic models implemented in simulation softwares and actual commercial inverters, (b) error metrics designed to account for a possible mismatch between the time resolution of simulation and measurements, and (c) analysis of the measurement-simulation mismatch to provide guidance to engineering personnel regarding model shortcomings. The performance of the platform has been illustrated using both simulated data and field measurements to validate/calibrate inverter models in GridLAB-D.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seasonal Reconfiguration of Electrical Distribution Systems to Mitigate the Impact of Electric Vehicle Charging

Power grids face challenges in their infrastructure related to the integration of electric vehicles (EV). In particular, EV charging stations may induce instability in key system parameters such as substantial voltage drops, active power losses, and transformer overload due to high demand during charging periods. This article presents a seasonal reconfiguration strategy based on the differential evolution (DE) algorithm, aimed at enhancing system performance under highly variable and stochastic load profiles, particularly those driven by EV charging. The DEA algorithm is hybridized with the find-union (FU) algorithm to efficiently ensure network radiality throughout the optimization process. The proposed methodology is validated on a hybrid distribution system composed of the IEEE 33-bus network, a modified IEEE 13-bus system, and a specific 13-bus microgrid. Results have demonstrated that seasonal reconfiguration significantly reduces active power losses and mitigates transformer loading during critical demand hours, thereby quantifiably increasing the system’s performance. As an integral component of the proposed approach, an analysis of CO2 emissions associated with energy losses is included, allowing a contextualized assessment of the environmental benefits of seasonal reconfiguration in various geographical areas.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Circulating Current Reduction of Back-to-Back MMC with Advanced Grid-Support Functionalities for Medium-Voltage Applications

A Lyapunov energy function based circulating current reduction scheme for a back to back modular multilevel converter based system for a microgrid application has been proposed in this digest. In order to ensure no circulating or zero sequence currents within the modules, the dynamics from one leg of the converter to the other are evaluated. A Lyapunov energy function is then developed and utilizing the circulating current dynamics of the converter the overall control law is implemented. In this digest a decentralized hierarchical control architecture has been implemented for the main current control; where the outer loop or the central controller implements the higher level grid interconnection functions as per IEEE 1547-2018 standards and the inner loop based on synchronous reference frame implements the current control architecture. The inner loops' outputs are the commanded converter voltages either on either side which are augmented by the Lyapunov energy function based circulating current suppression architecture. To evaluate the efficacy of the overall system, the overall system is modeled around a 300kVA back to back SiC multilevel modular converter used as a direct-connected medium voltage (MV) grid intertie based on MATLAB/Simulink domain. Several important case studies are presented in this paper to prove the effectiveness of the proposed architecture. case study results are presented.

circulating current↗

Addressing Data Veracity in Big Data Applications

Big data applications such as in smart electric grids, transportation, and remote environment monitoring involve geographically dispersed sensors that periodically send back information to central nodes. In many cases, data from sensors is not available at central nodes at a frequency that is required for real-time modeling and decision-making. This may be due to physical limitations of the transmission networks, or due to consumers limiting frequent transmission of data from sensors located at their premises for security and privacy concerns. Such scenarios lead to partial data problem and raise the issue of data veracity in big data applications. We describe a novel solution to the problem of making short term predictions (up to a few hours ahead) in absence of real-time data from sensors in Smart Grid. A key implication of our work is that by using real-time data from only a small subset of influential sensors, we are able to make predictions for all sensors. We thus reduce the communication complexity involved in transmitting sensory data in Smart Grids. We use real-world electricity consumption data from smart meters to empirically demonstrate the usefulness of our method. Our dataset consists of data collected at 15-min intervals from 170 smart meters in the USC Microgrid for 7 years, totaling 41,697,600 data points.

97 MATHEMATICS AND COMPUTING↗

Machine Learning-based False Data Injection Attack Detection and Localization in Power Grids

Cyberattacks on critical infrastructures can be catastrophic and bring nations to their knees. Therefore, detecting these attacks is crucial and challenging. This paper presents a novel approach for detecting and locating cyberattacks affecting an electrical power system. The adversary employs a man-in-the-middle technique to inject false data into the communication between distributed energy resources (DER) and Microgrid Controller (MGC) with the goal of disrupting power delivery. The approach for detection and localization is based on integrating multiple machine learning-based anomaly detection models that combine network traffic data and grid measurements. Experiments are performed to assess the method's performance using a hardware-in-the-loop real-time simulation testbed which includes Modbus TCP/IP communication. Power system topology and operating conditions are based on actual topology and real-world data provided by the Holy Cross Energy utility network. Results confirm that the method can be successfully employed for detecting and localizing cyberattacks.

Leao, Bruno P.↗

A Reduced-Order Aggregated Model for Parallel Inverter Systems with Virtual Oscillator Control

This paper introduces a reduced-order aggregated model for parallel-connected inverters controlled with virtual oscillator control (VOC). The premise of VOC is to modulate inverter dynamics to emulate those of nonlinear oscillators with the goal of realizing a stable ac microgrid in the absence of communication, synchronous generation, or a stiff grid. To obtain a reduced-order model for a system of parallel-connected inverters with VOC, we first formulate a set of scaling laws that describe how the controller and filter parameters of a given inverter depend on its voltage and power rating. Subsequently, we show that N parallel inverters which adhere to this scaling law can be modeled with the same structure and hence the same computational burden of the model of a single inverter. The proposed aggregate model is experimentally validated on a system of three parallel inverters with heterogeneous power ratings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power-Sharing between Grid-Forming and Grid-Following Inverters

Power-sharing between the grid-forming and the grid-following inverter in a small microgrid is a challenging task. Specifically, the decentralized droop-based power-sharing is difficult to achieve when the grid-forming inverter regulates the voltage and the frequency. This article proposes controllers for the grid-forming and the grid-following inverters, which ensure proportional power-sharing as well as regulate the voltage and the frequency. Both controllers use active power-frequency and reactive power-voltage droops. Additional secondary loops and secondary forward paths are added to the controller of the grid-forming inverter and the grid-following inverter, respectively, to ensure simultaneous voltage and frequency regulation and power-sharing. The efficacy of the proposed controllers for power-sharing is verified through experiment results in a multi-inverter testbed.

Sadeque, Fahmid↗

Angle Droop Design for Grid-Forming Inverters Considering Impacts of Virtual Impedance Control

Grid-forming inverters (GFMs) based on active power-frequency droop control and reactive power-voltage droop control have been developed in recent years, which can generate voltage and frequency references for islanded power systems or microgrids to improve system-wide synchronization and power-sharing capability. It is known that the control delays in GFMs may cause system harmonic instability. To eliminate this issue, virtual impedance techniques are normally adopted. This paper gives a comprehensive examination of the impacts of virtual impedance control block Z v in GFMs on system stability. It is revealed that although Z v is effective in eliminating system harmonic stability, it may ruin system synchronization stability as a side effect. To compensate for the negative impacts caused by Z v , an active power-angle control block is added into the conventional droop control. Design criteria are also proposed accordingly to ensure system stability over the entire frequency range. Simulations and experimental testing are conducted to validate the analysis and the proposed design guidelines. It can be concluded that the Z v control-caused grid-synchronization instability issues can be eliminated with an appropriate active power-angle droop design.

Kong, Le↗

A Current Limiting Control Strategy for Single-Loop Droop-Controlled Grid-Forming Inverters Under Balanced and Unbalanced Faults

Existing studies reporting current limiting control strategies for grid-forming inverters primarily focus on grid-forming inverters that use a multi-loop control structure. This study reports a current limiting control for grid-forming inverters that uses a single-loop control structure. The proposed current limiting control was implemented at the pulse width modulation (PWM) control layer to guarantee a rapid response. Once an overcurrent caused by severe faults is detected, the proposed control strategy immediately blocks relevant insulated-gate bipolar transistors (IGBTs) using a hysteresis loop, ensuring that the overcurrent is limited within a few PWM cycles. After the fault is cleared, the inverter seamlessly transfers back to droop control mode to maintain stability. The current limiting control has been tested in a microgrid environment operating in the OPAL-RT platform. Study results show that the control strategy can effectively limit the overcurrent under both balanced and unbalanced faults and can maintain system transient stability after the fault is cleared.

Du, Wei↗

On Stability of PQ-Controlled Grid-Following and Droop-Control Grid-Forming Inverters

In this paper, the nonlinearity impacts of PQ-control schemes and LCL filter parameter variations on the stability of grid-interactive inverters are studied under weak grid conditions. This work demonstrates that the control nonlinearity and parameter variations can cause unexpected instability at low power levels. This instability issue in the nominal operating range may occur under specific control parameters due to the shift of the low-frequency eigenvalues of PQ-controlled inverters. A full-order small-signal model for PQ-controlled inverters is applied to analyze this instability issue. Furthermore, the impacts of the droop coefficients on the stability of the droop-controlled grid-forming inverter are also investigated using the closed-loop inverter model. The findings are experimentally verified using a small-scale two-level 208 V, 5 kVA inverter feeding a 12 kW NHR 9410 power grid emulator and a hardware setup of a microgrid fed by two 5 kVA 208V inverters.

Hossen, Tareq↗

Quantitative Small-Signal Stability Analysis of Grid-Forming Inverters in Large-Scale Power Systems

In this paper, the challenges induced by the integration of inverter-based resources (IBRs) into existing power systems are discussed. Although the grid-forming (GFM) control has been used to enhance system performance in multiple sections of electric power systems (e.g., transmission and distribution systems, microgrids, among others), the coupling mechanism between GFM inverter and various types of other components in modern power systems should be clearly explored. Existing analyses mainly focus on qualitative investigations that verify the effectiveness of deploying GFM inverters for stability enhancement. A holistic system-level quantitative analysis is still missing to verify the detailed benefits of GFM inverters and their interactions with other generation units (e.g., synchronous generators [SGs], conventional grid-following [GFL] inverters, synchronous condensers, among others). To fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established along with the customized power flow analysis for varying steady-state operating points. Further, a quantitative method is proposed to identify the impacts of GFM inverters on system performance with an emphasis on a quantifiable stability margin and a complete modal analysis at the system level. Finally, a realistic test system is used to verify the proposed approach.

grid-following↗

Implementation of Advanced Grid Support Functionalities by Smart Operation of Residential Loads with low Cost Converter Interface

This paper investigates a grid-supportive load concept for small-scale residential appliances, focusing on a residential refrigerator. Power consumption is adjusted based on grid conditions to achieve IEEE-1547 grid support functions. Two key aspects are presented: a low-cost refrigerator converter with Lyapunov energy function-based local controllers for speed control, and the impact on a standard microgrid system, demonstrating advanced grid support from the load side. This method enhances grid resilience and reliability and can be extended to other residential loads. The study contributes to efficient and robust grid-supportive load management systems, showing promising performance. This approach has the potential to improve overall grid stability and can be adapted for various types of residential appliances. The modeling and simulations in MATLAB/Simulink and PLECS confirm the feasibility and effectiveness of the proposed solution. Future work will explore real-world implementation and scalability of this concept for broader applications.

grid supportive loads (GSL)↗

A Graph-Net with Node Embeddings to Detect False Data Injection Attacks in Photovoltaic Systems

Distributed energy resources (DER) contribute to the operational stability of the larger power grid both at utility-scale as well as commercial and residential scales in aggregated forms. These DER in-turn are susceptible to increasing cyber threats. An adversary can plug into the same local network that a field photovoltaic (PV) system uses to interconnect its data loggers and inverters and manipulate certain measurements collected from the network or trick existing irradiance and inverter readings through false data injection attacks (FDIA). Control routines that rely on these measurements can propagate the false data, impacting critical decisions that result in a suboptimal operation or even cause intentional harm leading to inverter-tripping or unscheduled loads that need to be shed. To detect FDIA in PV systems, the paper introduces an attention-based graph neural network with node embeddings and applied it to a simple prototypical DC-coupled microgrid with PV, energy storage, and load. The algorithm shows a detection accuracy of up to 98.95%. The proposed FDIA detection technique will provide micro-grid operators with an effective method to safeguard their systems, guaranteeing the secure and reliable operation.

Parvez, Imtiaz [Utah Valley University]↗

Developing Use Cases for Evaluation of ADMS Applications to Accelerate Technology Adoption: Preprint

Grid modernization for the distribution systems comprise of the ability to effectively monitor and manage unplanned events while ensuring reliable operations. Integration of Distributed Energy Resources (DERs) and proliferation of autonomous smart controllers like microgrids and smart inverters in the distribution networks challenge the status quo of distribution system operations. Advanced Distribution Management System (ADMS) technologies are being increasingly deployed to manage the complexities of operating distribution systems. The ability to evaluate the ADMS applications in specific utility environments and for future scenarios will accelerate wider adoption of the ADMS and will lower the risks and costs of their implementation. This paper addresses the first step - identify and define the use cases for evaluating these applications. The applications that are selected for this discussion include Volt-VAr Optimization (VVO), Fault Location Isolation and Service Restoration (FLISR), Online Power Flow (OLPF)/Distribution System State Estimation (DSSE) and Market Participation. A technical description and general operational requirements for each of these applications is presented. The test scenarios that are most relevant to the utility challenges are also addressed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Two-Layer Predictive Controller for V2G and G2V Services Using on Wireless Power Transfer Technology

This paper presents a comprehensive solution that allows electric vehicles (EV) to autonomously charge and discharge their batteries wirelessly during long term parking and/or the transient stops. A two-layer power-flow controller for bidirectional wireless power transfer system (BWPTS) in EVs applications is proposed. The proposed controller can manage the bidirectional power-flow between EV and surrounding infrastructures such as power grid, home microgrid, building micro-grid, road or another vehicle. It consists of two levels of control; the first is responsible for communicating with the surrounding infrastructures and gathering information from driver, charging station, power grid and battery management system and then, based on these information, it estimates the EV's psychological price as a function of its battery's state-of-charge (SOC) and compares it with the energy price to decide whether to charge, discharge or abstain, and how much the charging or discharging rate. The second layer receives the reference signal from the first one and generates the control parameters for two synchronized resonant converters (one is on the vehicle side and the other is on the grid side) to provide the requited power-flow. The proposed controller is adaptively estimating the system parameters to consider the misalignment conditions effects on the system performance. The parameter estimation is achieved using only one voltage sensor. The second layer control is designed based on a new analytical modeling for the power flow in the system. For verification purposes, a prototype for BWPTS was built and driven by the proposed controller, which was implemented using a field-programmable gate array (FPGA) integrated circuit. The proposed controller provides very fast and stable response during both the transient and steady state operation in comparison with the conventional PI controller.

33 ADVANCED PROPULSION SYSTEMS↗

A Low Voltage DC Power Electronic Hub to Support Buildings

This paper presents the communication, control, and architecture, for a low voltage (nominal 480V) hybrid AC/DC microgrid for supporting small commercial buildings with critical data center loads. The proposed system is based on a dc-power electronic hub (PEH) that seamlessly integrates renewable energy resources, energy storage, and back-up generation to support commercial building economical energy management and reliability. This PEH concept provides a parallelization of critical power to the commercial and industrial buildings leading to increased efficiency and reliability compared to traditional uninterruptable power supplies. The demonstration of the proposed PEH architecture and controls is conducted through a controller hardware in the loop validation.

Starke, Michael↗