Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Polyethylene in Dead-End Silica Nanopores: Forces and Mobility from Non-Equilibrium Statistical Mechanics and Exchange Spectroscopy Nuclear Magnetic Resonance

Billions of tons of plastic have been produced, and only a small fraction of this has been recycled. Tennakoon et al. [Nature Catalysis 3, 893 (2020)] developed a catalyst that repeatedly cleaves C 10 –C 30 hydrocarbons from the end of a polyethylene chain. The reaction occurs at a Pt nanoparticle at the base of a cylindrical silica mesopore with a diameter of 2 nm and a length of 110 nm. Portions of the polymer situated inside the pore can be differentiated from those outside using 13 C nuclear magnetic resonance (NMR), allowing the dynamics and extent of polymer threading to be monitored using two-dimensional (2D) exchange spectroscopy NMR. Here we construct a Fokker–Planck equation for the polymer dynamics by assuming a reptation diffusivity and a graduated adsorption free energy that depends linearly on the depth of polymer penetration in the pore. The solutions allow us to predict the intensities of the 2D NMR resonances as a function of time. We use the solutions to extract a polymer diffusivity at each temperature and estimate the per-segment desorption free energy, enthalpy, and entropy. Random and systematic errors are examined to test key assumptions in the theory and interpretation of the experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards quantifying the role of exact exchange in predictions of transition metal complex properties

We estimate the prediction sensitivity with respect to Hartree-Fock exchange in approximate density functionals for representative Fe(II) and Fe(III) octahedral complexes. Based on the observation that the range of parameters spanned by the most widely employed functionals is relatively narrow, we compute electronic structure property and spin-state orderings across a relatively broad range of Hartree-Fock exchange (0%-50%) ratios. For the entire range considered, we consistently observe linear relationships between spin-state ordering that differ only based on the element of the direct ligand and thus may be broadly employed as measures of functional sensitivity in predictions of organometallic compounds. The role Hartree-Fock exchange in hybrid functionals is often assumed to play is to correct self-interaction error-driven electron delocalization (e.g., from transition metal centers to neighboring ligands). Surprisingly, we instead observe that increasing Hartree-Fock exchange reduces charge on iron centers, corresponding to effective delocalization of charge to ligands, thus challenging notions of the role of Hartree-Fock exchange in shifting predictions of spin-state ordering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanical Design of a UHV Non-magnetic Kappa Diffractometer

A UHV non-magnetic kappa geometry diffractometer has been designed for the resonant soft X-ray scattering (RSXS) branch of the Intermediate Energy X-ray (IEX) beamline at the Advanced Photon Source (APS), Argonne National Laboratory. The kappa geometry allows for a large q-range and space for a sample environment (electric or magnetic fields). To avoid distorting the sample environment field, non-magnetic SmarAct, GmbH stages are used for the 4)-axis, X, Y, and Z linear stages. The ic and 0 axes are controlled by high-precision UHV compatible Physik Instrumente (PI) GmbH & Co. rotation stages. The design goal was to achieve a 50 gm sphere of confusion. To achieve this, iterative designs were developed using FEA and commercial stages were chosen that had minimal wobble, eccentricity, and flatness errors.

X-ray diffractometer↗

Comprehensive scenario for single-crystal growth and doping dependence of resistivity and anisotropic upper critical fields in (Ba1-xKx)Fe2As2 (0.22 <= X <= 1)

Large high-quality single crystals of hole-doped iron-based superconductor (Ba1-xKx)Fe2As2 were grown over a broad composition range 0.22 <= x <= 1 by inverted temperature gradient method. We found that high soaking temperature, fast cooling rate, and an adjusted temperature window of the growth are necessary to obtain single crystals of heavily K-doped crystals (0.65 <= x <= 0.92) with narrow compositional distributions as revealed by sharp superconducting transitions in magnetization measurements and close to 100% superconducting volume fraction. The crystals were extensively characterized by x-ray and compositional analysis, revealing monotonic evolution of the c-axis crystal lattice parameter with K substitution. Quantitative measurements of the temperature-dependent in-plane resistivity rho(T) found doping-independent, constant within error bars, resistivity at room temperature, rho(300 K), in sharp contrast with the significant doping dependence in electron and isovalent substituted BaFe2As2 based compositions. The shape of the temperature-dependent resistivity, rho(T), shows systematic doping-evolution, being close to T-2 in overdoped and revealing significant contribution of the T-linear component at optimum doping. The slope of the upper critical field, d H-c2/dT, scales linearly with T-c for both H parallel to c, H-c2,(c), and H parallel to ab, H-c2,H-ab. The anisotropy of the upper critical field. equivalent to Hc(2,ab)/H-c2,H-c determined near zero-field T-c increases from similar to 2 to 4-5 with increasing K doping level from optimal x similar to 0.4 to strongly overdoped x = 1.

36 MATERIALS SCIENCE↗

Use of a line-pair resolution phantom for comprehensive quality assurance of electronic portal imaging devices based on fundamental imaging metrics

Image guided radiation therapy solutions based on megavoltage computed tomography (MVCT) involve the extension of electronic portal imaging devices (EPIDs) from their traditional role of weekly localization imaging and planar dose mapping to volumetric imaging for 3D setup and dose verification. To sustain the potential advantages of MVCT, EPIDs are required to provide improved levels of portal image quality. Therefore, it is vital that the performance of EPIDs in clinical use is maintained at an optimal level through regular and rigorous quality assurance (QA). Traditionally, portal imaging QA has been carried out by imaging calibrated line-pair and contrast resolution phantoms and obtaining arbitrarily defined QA indices that are usually dependent on imaging conditions and merely indicate relative trends in imaging performance. They are not adequately sensitive to all aspects of image quality unlike fundamental imaging metrics such as the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) that are widely used to characterize detector performance in radiographic imaging and would be ideal for QA purposes. However, due to the difficulty of performing conventional MTF measurements, they have not been used for routine clinical QA. The authors present a simple and quick QA methodology based on obtaining the MTF, NPS, and DQE of a megavoltage imager by imaging standard open fields and a bar-pattern QA phantom containing 2 mm thick tungsten line-pair bar resolution targets. Our bar-pattern based MTF measurement features a novel zero-frequency normalization scheme that eliminates normalization errors typically associated with traditional bar-pattern measurements at megavoltage x-ray energies. The bar-pattern QA phantom and open-field images are used in conjunction with an automated image analysis algorithm that quickly computes the MTF, NPS, and DQE of an EPID system. Our approach combines the fundamental advantages of linear systems metrics such as robustness, sensitivity across the full spatial frequency range of interest, and normalization to imaging conditions (magnification, system gain settings, and exposure), with the simplicity, ease, and speed of traditional phantom imaging. The algorithm was analyzed for accuracy and sensitivity by comparing with a commercial portal imaging QA method (PIPSPRO, Standard Imaging, Middleton, WI) on both first-generation lens-coupled and modern a-Si flat-panel based clinical EPID systems. The bar-pattern based QA measurements were found to be far more sensitive to even small levels of degradation in spatial resolution and noise. The bar-pattern based QA methodology offers a comprehensive image quality assessment tool suitable for both commissioning and routine EPID QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of image quality and image-guidance performance of a preclinical microirradiator

Purpose: To assess image quality and image-guidance capabilities of a cone-beam CT based small-animal image-guided irradiation unit (micro-IGRT). Methods: A micro-IGRT system has been developed in collaboration with the authors' laboratory as a means to study the radiobiological effects of conformal radiation dose distributions in small animals. The system, the X-Rad 225Cx, consists of a 225 kVp x-ray tube and a flat-panel amorphous silicon detector mounted on a rotational C-arm gantry and is capable of both fluoroscopic x-ray and cone-beam CT imaging, as well as image-guided placement of the radiation beams. Image quality (voxel noise, modulation transfer, CT number accuracy, and geometric accuracy characteristics) was assessed using water cylinder and micro-CT test phantoms. Image guidance was tested by analyzing the dose delivered to radiochromic films fixed to BB's through the end-to-end process of imaging, targeting the center of the BB, and irradiation of the film/BB in order to compare the offset between the center of the field and the center of the BB. Image quality and geometric studies were repeated over a 5-7 month period to assess stability. Results: CT numbers reported were found to be linear (R{sup 2}{>=}0.998) and the noise for images of homogeneous water phantom was 30 HU at imaging doses of approximately 1 cGy (to water). The presampled MTF at 50% and 10% reached 0.64 and 1.35 mm{sup -1}, respectively. Targeting accuracy by means of film irradiations was shown to have a mean displacement error of [{Delta}x,{Delta}y,{Delta}z]=[-0.12,-0.05,-0.02] mm, with standard deviations of [0.02, 0.20, 0.17] mm. The system has proven to be stable over time, with both the image quality and image-guidance performance being reproducible for the duration of the studies. Conclusions: The micro-IGRT unit provides soft-tissue imaging of small-animal anatomy at acceptable imaging doses ({<=}1 cGy). The geometric accuracy and targeting systems permit dose placement with submillimeter accuracy and precision. The system has proven itself to be stable over 2 yr of routine laboratory use (>1800 irradiations) and provides a platform for the exploration of targeted radiation effects in small-animal models.

60 APPLIED LIFE SCIENCES↗

Acoustic Codes in 2D Spherical Coordinate

Finite-difference methods are widely used to simulate infrasound propagation in the atmosphere. Flexibility of finite-difference scheme allows implementation of highly heterogeneous media for sound propagation as well as complex source models for sound generation. While full 3-D finite-difference methods have been utilized for local infrasound propagation with pronounced topography, 2-D modeling approach has been preferred for regional and global propagation as full 3-D methods generally require enormous computational resources. Infrasound propagation is often simulated with a second-order finite difference scheme. This lowest-order finite-difference scheme is robust and straightforward to implement complex boundary conditions, but the solution includes large error with numerical dispersion and dissipation. This large numerical error may make the second-order finite-difference not optimal for long range infrasound propagation modeling as the numerical dispersion degrades the accuracy of the solution unacceptably. Here, we developed a high-order finite-difference solver for long-range infrasound simulation. The high-order scheme is particularly popular for linear wave modeling in aeroacoustics owing to its low-dispersive and low-dissipative behavior. We develop and evaluate a high-order finite difference scheme in 2-D axisymmetric coordinates. The axisymmetry allows to approximate 3-D spherical sound propagation and amplitude attenuation by a 2-D method. AC2Dr is developed to simulate infrasound propagation in realistic atmosphere, but can be used for linear acoustic waves in general materials with background flow. AC2Dr in an axisymmetric coordinates allows for spherical radiation of acoustic waves from compact sources.

Sjogreen, Bjorn↗

THE MASS DEPENDENCE BETWEEN PROTOPLANETARY DISKS AND THEIR STELLAR HOSTS

We present a substantial extension of the millimeter (mm) wave continuum photometry catalog for circumstellar dust disks in the Taurus star-forming region, based on a new ''snapshot'' {lambda} = 1.3 mm survey with the Submillimeter Array. Combining these new data with measurements in the literature, we construct a mm-wave luminosity distribution, f(L{sub mm}), for Class II disks that is statistically complete for stellar hosts with spectral types earlier than M8.5 and has a 3{sigma} depth of roughly 3 mJy. The resulting census eliminates a longstanding selection bias against disks with late-type hosts, and thereby demonstrates that there is a strong correlation between L{sub mm} and the host spectral type. By translating the locations of individual stars in the Hertzsprung-Russell diagram into masses and ages, and adopting a simple conversion between L{sub mm} and the disk mass, M{sub d} , we confirm that this correlation corresponds to a statistically robust relationship between the masses of dust disks and the stars that host them. A Bayesian regression technique is used to characterize these relationships in the presence of measurement errors, data censoring, and significant intrinsic scatter: the best-fit results indicate a typical 1.3 mm flux density of {approx}25 mJy for 1 M{sub Sun} hosts and a power-law scaling L{sub mm}{proportional_to}M{sub *}{sup 1.5-2.0}. We suggest that a reasonable treatment of dust temperature in the conversion from L{sub mm} to M{sub d} favors an inherently linear M{sub d} {proportional_to}M{sub *} scaling, with a typical disk-to-star mass ratio of {approx}0.2%-0.6%. The measured rms dispersion around this regression curve is {+-}0.7 dex, suggesting that the combined effects of diverse evolutionary states, dust opacities, and temperatures in these disks imprint a full width at half-maximum range of a factor of {approx}40 on the inferred M{sub d} (or L{sub mm}) at any given host mass. We argue that this relationship between M{sub d} and M{sub *} likely represents the origin of the inferred correlation between giant planet frequency and host star mass in the exoplanet population, and provides some basic support for the core accretion model for planet formation. Moreover, we caution that the effects of incompleteness and selection bias must be considered in comparative studies of disk evolution, and illustrate that fact with statistical comparisons of f(L{sub mm}) between the Taurus catalog presented here and incomplete subsamples in the Ophiuchus, IC 348, and Upper Sco young clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

XCOM intrinsic dimensionality for low-Z elements at diagnostic energies

Purpose: To determine the intrinsic dimensionality of linear attenuation coefficients (LACs) from XCOM for elements with low atomic number (Z = 1-20) at diagnostic x-ray energies (25-120 keV). H{sub 0}{sup q}, the hypothesis that the space of LACs is spanned by q bases, is tested for various q-values. Methods: Principal component analysis is first applied and the LACs are projected onto the first q principal component bases. The residuals of the model values vs XCOM data are determined for all energies and atomic numbers. Heteroscedasticity invalidates the prerequisite of i.i.d. errors necessary for bootstrapping residuals. Instead wild bootstrap is applied, which, by not mixing residuals, allows the effect of the non-i.i.d residuals to be reflected in the result. Credible regions for the eigenvalues of the correlation matrix for the bootstrapped LAC data are determined. If subsequent credible regions for the eigenvalues overlap, the corresponding principal component is not considered to represent true data structure but noise. If this happens for eigenvalues l and l + 1, for any l{<=}q, H{sub 0}{sup q} is rejected. Results: The largest value of q for which H{sub 0}{sup q} is nonrejectable at the 5%-level is q = 4. This indicates that the statistically significant intrinsic dimensionality of low-Z XCOM data at diagnostic energies is four. Conclusions: The method presented allows determination of the statistically significant dimensionality of any noisy linear subspace. Knowledge of such significant dimensionality is of interest for any method making assumptions on intrinsic dimensionality and evaluating results on noisy reference data. For LACs, knowledge of the low-Z dimensionality might be relevant when parametrization schemes are tuned to XCOM data. For x-ray imaging techniques based on the basis decomposition method (Alvarez and Macovski, Phys. Med. Biol. 21, 733-744, 1976), an underlying dimensionality of two is commonly assigned to the LAC of human tissue at diagnostic energies. The finding of a higher statistically significant dimensionality thus raises the question whether a higher assumed model dimensionality (now feasible with the advent of multibin x-ray systems) might also be practically relevant, i.e., if better tissue characterization results can be obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-628: Effect of Dose Rate and Leakage Correction for Dosimetric Leaf Gap Measurement

Purpose: To study the dose rate response of Mapcheck and quantify/correct dose rate/leakage effect on IMRT QA. Evaluate the dose rate/leakage effect on dosimetric leaf gap (DLG) measurement. Methods: Varian Truebeam Linac with HD120 MLC was used for all measurement, it is capable to adjust dose rate from 600MU/min to 5MU/min. Fluke Advanced Therapy Doisemter and PTW 30013 Farmer chamber for chamber measurement; SunNuclear Mapcheck2 with 5cm total buildup for diode measurement. DLG was measured with both chamber and diode.Diode response was measured by varies dose rate, while fixed mapcheck setup and total MU. MLC Leakage was measured with both chamber and diode. Mapcheck measurement was saved as movie file (mcm file), which include measurement updated every 50mSec. The difference between intervals can be converted to dose and dose rate and leakage response correction can be applied to them. Results: DLG measurement results with chamber and diode were showed as follows, the DLG value is 0.36 vs. 0.24mm respectively. Diode dose rate response drops from 100% at 600MU/min to 95.5% at 5MU/min as follows. MLC Leakage measured with diode is 1.021%, which is 9% smaller than 1.112% from chamber measurement. By apply the dose rate and leakage correction, the residue error reduced 2/3. Conclusions: Diode has lower response at lower dose rate, as low as 4.5% for 5MU/min; diode has lower energy response for low energy too, 5% lower for Co-60 than 6MV. It partially explains the leakage difference of 9% between chamber and diode. Lower DLG with diode is because of the lower response at narrower gap, in Eclipse however DLG need to increase to makeup lower response, which is over correction for chamber though. Correction can reduce error by 2/3, the rest 1/3 can be corrected by scatter effect, which is under study.

07 ISOTOPE AND RADIATION SOURCES↗

SU-G-JeP4-01: An Assessment of a Microsoft Kinect V2 Sensor for Voluntary Breath-Hold Monitoring in Radiotherapy

Purpose: To determine whether the Microsoft Kinect Version 2 (Kinect v2), a commercial off-the-shelf (COTS) depth sensors designed for entertainment purposes, were robust to the radiotherapy treatment environment and could be suitable for monitoring of voluntary breath-hold compliance. This could complement current visual monitoring techniques, and be useful for heart sparing left breast radiotherapy. Methods: In-house software to control Kinect v2 sensors, and capture output information, was developed using the free Microsoft software development kit, and the Cinder creative coding C++ library. Each sensor was used with a 12m USB 3.0 active cable. A solid water block was used as the object. The depth accuracy and precision of the sensors was evaluated by comparing Kinect reported distance to the object with a precision laser measurement across a distance range of 0.6m to 2.0 m. The object was positioned on a high-precision programmable motion platform and moved in two programmed motion patterns and Kinect reported distance logged. Robustness to the radiation environment was tested by repeating all measurements with a linear accelerator operating over a range of pulse repetition frequencies (6Hz to 400Hz) and dose rates 50 to 1500 monitor units (MU) per minute. Results: The complex, consistent relationship between true and measured distance was unaffected by the radiation environment, as was the ability to detect motion. Sensor precision was < 1 mm and the accuracy between 1.3 mm and 1.8 mm when a distance correction was applied. Both motion patterns were tracked successfully with a root mean squared error (RMSE) of 1.4 and 1.1 mm respectively. Conclusion: Kinect v2 sensors are capable of tracking pre-programmed motion patterns with an accuracy <2 mm and appear robust to the radiotherapy treatment environment. A clinical trial using Kinect v2 sensor for monitoring voluntary breath hold has ethical approval and is open to recruitment. The authors are supported by a National Institute of Health Research (NIHR) Career Development Fellowship (CDF-2013-06-005). Microsoft Corporation donated three sensors. The views expressed in this publication are those of the author(s) and not necessarily those of the NHS, the National Institute for Health Research or the Department of Health.

60 APPLIED LIFE SCIENCES↗

A coupled multipoint stress–multipoint flux mixed finite element method for the Biot system of poroelasticity

In this work, we present a mixed finite element method for a five-field formulation of the Biot system of poroelasticity that reduces to a cell-centered pressure–displacement system on simplicial and quadrilateral grids. A mixed stress–displacement–rotation formulation for elasticity with weak stress symmetry is coupled with a mixed velocity–pressure Darcy formulation. The spatial discretization is based on combining the multipoint stress mixed finite element (MSMFE) method for elasticity and the multipoint flux mixed finite element (MFMFE) method for Darcy flow. It uses the lowest order Brezzi–Douglas–Marini mixed finite element spaces for the poroelastic stress and Darcy velocity, piecewise constant displacement and pressure, and continuous piecewise linear or bilinear rotation. A vertex quadrature rule is applied to the velocity, stress, and stress–rotation bilinear forms, which block-diagonalizes the corresponding matrices and allows for local velocity, stress, and rotation elimination. This leads to a cell-centered positive-definite system for pressure and displacement at each time step. We perform error analysis for the semidiscrete and fully discrete formulations, establishing first order convergence for all variables in their natural norms. The numerical tests confirm the theoretical convergence rates and illustrate the locking-free property of the method.

42 ENGINEERING↗

Forces from Stochastic Density Functional Theory under Nonorthogonal Atom-Centered Basis Sets

We develop a formalism for calculating forces on the nuclei within the linear-scaling stochastic density functional theory (sDFT) in a nonorthogonal atom-centered basis set representation (Fabian et al. Wiley Interdiscip. Rev.: Comput. Mol. Sci. 2019, 9, e1412, 10.1002/wcms.1412) and apply it to the Tryptophan Zipper 2 (Trp-zip2) peptide solvated in water. We use an embedded-fragment approach to reduce the statistical errors (fluctuation and systematic bias), where the entire peptide is the main fragment and the remaining 425 water molecules are grouped into small fragments. We analyze the magnitude of the statistical errors in the forces and find that the systematic bias is of the order of 0.065 eV/Å (~1.2 × 10 -3 E h / a 0 ) when 120 stochastic orbitals are used, independently of system size. This magnitude of bias is sufficiently small to ensure that the bond lengths estimated by stochastic DFT (within a Langevin molecular dynamics simulation) will deviate by less than 1% from those predicted by a deterministic calculation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomistic non-adiabatic dynamics of the LH2 complex with a GPU-accelerated ab initio exciton model

We recently outlined an efficient multi-tiered parallel ab initio excitonic framework that utilizes time dependent density functional theory (TDDFT) to calculate ground and excited state energies and gradients of large supramolecular complexes in atomistic detail – enabling us to undertake non-adiabatic simulations which explicitly account for the coupled anharmonic vibrational motion of all the constituent atoms in a supramolecular system. Here we apply that framework to the 27 coupled bacterio-chlorophyll-a chromophores which make up the LH2 complex, using it to compute an on-the-fly nonadiabatic surface-hopping (SH) trajectory of electronically excited LH2. Part one of this article is focussed on calibrating our ab initio exciton Hamiltonian using two key parameters: a shift δ, which corrects for the error in TDDFT vertical excitation energies; and an effective dielectric constant ε, which describes the average screening of the transition-dipole coupling between chromophores. Using snapshots obtained from equilibrium molecular dynamics simulations (MD) of LH2, we tune the values of both δ and ε through fitting to the thermally broadened experimental absorption spectrum, giving a linear absorption spectrum that agrees reasonably well with experiment. In part two of this article, we construct a time-resolved picture of the coupled vibrational and excitation energy transfer (EET) dynamics in the sub-picosecond regime following photo-excitation. Assuming Franck–Condon excitation of a narrow eigenstate band centred at 800 nm, we use surface hopping to follow a single nonadiabatic dynamics trajectory within the full eigenstate manifold. Consistent with experimental data, this trajectory gives timescales for B800→B850 population transfer (τ B800→B850 ) between 650–1050 fs, and B800 population decay (τ 800→ ) between 10–50 fs. The dynamical picture that emerges is one of rapidly fluctuating LH2 eigenstates that are delocalized over multiple chromophores and undergo frequent crossing on a femtosecond timescale as a result of the atomic vibrations of the constituent chromophores. The eigenstate fluctuations arise from disorder that is driven by vibrational dynamics with multiple characteristic timescales. The scalability of our ab initio excitonic computational framework across massively parallel architectures opens up the possibility of addressing a wide range of questions, including how specific dynamical motions impact both the pathways and efficiency of electronic energy-transfer within large supramolecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of birefringent fibre joints on the visibility drift in a Mach – Zehnder interferometer

It is shown that imperfect joints of linear birefringent fibres in a fibre interferometer may result in an uncontrolled visibility drift under varying environmental conditions even with a standard phase matching device. As an example, a double Mach – Zehnder interferometer is considered, which is employed in schemes of quantum key distribution. Results of numerical simulation demonstrate the standard deviation of the quantum bit error rate (QBER), which is comparable to an average QBER value. (paper)

36 MATERIALS SCIENCE↗

A Bloom Filter Based Scalable Data Integrity Check Tool for Large-Scale Dataset

Large scale HPC applications are becoming increasingly data intensive. At Oak Ridge Leadership Computing Facility (OLCF), we are observing the number of files curated under individual project are reaching as high as 200 millions and project data size is exceeding petabytes. These simulation datasets, once validated, often needs to be transferred to archival system for long term storage or shared with the rest of the research community. Ensuring the data integrity of the full dataset at this scale is paramount important but also a daunting task. This is especially true considering that most conventional tools are serial and file-based, unwieldy to use and/or can't scale to meet user's demand.To tackle this particular challenge, this paper presents the design, implementation and evaluation of a scalable parallel checksumming tool, fsum, which we developed at OLCF. It is built upon the principle of parallel tree walk and work-stealing pattern to maximize parallelism and is capable of generating a single, consistent signature for the entire dataset at extreme scale. We also applied a novel bloom-filter based technique in aggregating signatures to overcome the signature ordering requirement. Given the probabilistic nature of bloom filter, we provided a detailed error and trade-off analysis. Using multiple datasets from production environment, we demonstrated that our tool can efficiently handle both very large files as well as many small-file based datasets. Our preliminary test showed that on the same hardware, it outperforms conventional tool by as much as 4×. It also exhibited near-linear scaling properties when provisioned with more compute resources.

97 MATHEMATICS AND COMPUTING↗

Dosimetric evaluation of the interplay effect in respiratory-gated RapidArc radiation therapy

Purpose: Volumetric modulated arc therapy (VMAT) with gating capability has had increasing adoption in many clinics in the United States. In this new technique, dose rate, gantry rotation speed, and the leaf motion speed of multileaf collimators (MLCs) are modulated dynamically during gated beam delivery to achieve highly conformal dose coverage of the target and normal tissue sparing. Compared with the traditional gated intensity-modulated radiation therapy technique, this complicated beam delivery technique may result in larger dose errors due to the intrafraction tumor motion. The purpose of this work is to evaluate the dosimetric influence of the interplay effect for the respiration-gated VMAT technique (RapidArc, Varian Medical Systems, Palo Alto, CA). Our work consisted of two parts: (1) Investigate the interplay effect for different target residual errors during gated RapidArc delivery using a one-dimensional moving phantom capable of producing stable sinusoidal movement; (2) Evaluate the dosimetric influence in ten clinical patients’ treatment plans using a moving phantom driven with a patient-specific respiratory curve. Methods: For the first part of this study, four plans were created with a spherical target for varying residual motion of 0.25, 0.5, 0.75, and 1.0 cm. Appropriate gating windows were applied for each. The dosimetric effect was evaluated using EDR2 film by comparing the gated delivery with static delivery. For the second part of the project, ten gated lung stereotactic body radiotherapy cases were selected and reoptimized to be delivered by the gated RapidArc technique. These plans were delivered to a phantom, and again the gated treatments were compared to static deliveries by the same methods. Results: For regular sinusoidal motion, the dose delivered to the target was not substantially affected by the gating windows when evaluated with the gamma statistics, suggesting the interplay effect has a small role in respiratory-gated RapidArc therapy. Varied results were seen when gated therapy was performed on the patient plans that could only be attributed to differences in patient respiratory patterns. Patients whose plans had the largest percentage of pixels failing the gamma statistics exhibited irregular breathing patterns including substantial interpatient variation in depth of respiration. Conclusions: The interplay effect has a limited impact on gated RapidArc therapy when evaluated with a linear phantom. Variations in patient breathing patterns, however, are of much greater clinical significance. Caution must be taken when evaluating patients’ respiratory efforts for gated arc therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗