Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIMB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

File Specification for MERRA-2 Stratospheric Composition Reanalysis of Aura MLS (M2-SCREAM)

This document provides a brief description of the output collections from the MERRA-2 Stratospheric Composition Reanalysis of the Aura Microwave Limb Sounder (M2-SCREAM) produced at NASA’s Global Modeling and Assimilation Office. These data are generated by assimilating retrievals from the Microwave Limb Sounder (MLS) and the Ozone Monitoring Instrument (OMI) into the Global Earth Observing System (GEOS) Constituent Data Assimilation System (CoDAS) driven by meteorological fields from MERRA-2. M2-SCREAM assimilates hydrochloric acid (HCl), nitric acid (HNO3), stratospheric water vapor (H2O), nitrous oxide (N2O) and ozone with a system equipped with a version of the GEOS general circulation model and a stratospheric chemistry model, StratChem. Assimilated fields are provided globally at 0.5° by 0.625° resolution at three-hourly frequencies from 2004/09/01 to 2021. Assimilation uncertainties for each of the assimilated constituents are calculated from the CoDAS statistical output (Wargan et al., 2022) and provided as global full-resolution three-dimensional monthly files.

Krzysztof Wargan↗

M2-SCREAM: A Stratospheric Composition Reanalysis of Aura MLS Data With MERRA-2 Transport

MERRA-2 Stratospheric Composition Reanalysis of Aura Microwave Limb Sounder (M2-SCREAM) is a new reanalysis of stratospheric ozone, water vapor, hydrogen chloride (HCl), nitric acid (HNO 3 ) and nitrous oxide (N 2 O) between 2004 and the present (with a latency of several months). The assimilated fields are provided at a 50-km horizontal resolution and at a three-hourly frequency. M2-SCREAM assimilates version 4.2 Microwave Limb Sounder (MLS) profiles of the five constituents alongside total ozone column from the Ozone Monitoring Instrument. Dynamics and tropospheric water vapor are constrained by the MERRA-2 reanalysis. The assimilated species are in excellent agreement with the MLS observations, except for HNO 3 in polar night, where data are not assimilated. Comparisons against independent observations show that the reanalysis realistically captures the spatial and temporal variability of all the assimilated constituents. In particular, the standard deviations of the differences between M2-SCREAM and constituent mixing ratio data from The Atmospheric Chemistry Experiment Fourier Transform Spectrometer are much smaller than the standard deviations of the measured constituents. Evaluation of the reanalysis against aircraft data and balloon-borne frost point hygrometers indicates a faithful representation of small-scale structures in the assimilated water vapor, HNO 3 and ozone fields near the tropopause. Comparisons with independent observations and a process-based analysis of the consistency of the assimilated constituent fields with the MERRA-2 dynamics and with large-scale stratospheric processes demonstrate the utility of M2-SCREAM for scientific studies of chemical and transport variability on time scales ranging from hours to decades. Analysis uncertainties and guidelines for data usage are provided.

MERRA-2↗

Seasonal Variation of Thermospheric Composition Observed by NASA GOLD

We examine characteristics of the seasonal variation of thermospheric composition using column number density ratio ∑O/N(2) observed by the NASA Global Observations of Limb and Disk (GOLD) mission from low-mid to mid-high latitudes. We also use ∑O/N(2) derived from the Global Ultraviolet Imager (GUVI) limb measurements onboard the Thermosphere Ionosphere Mesosphere Energetics and Dynamics (TIMED) satellite and estimated by the NRLMSISE-00 empirical model to aid our investigation. We found that the ∑O/N(2) seasonal variation is hemispherically asymmetric: in the southern hemisphere, it exhibits the well-known annual and semiannual pattern, with highs near the equinoxes, and primary and secondary lows near the solstices. In the northern hemisphere, it is dominated by an annual variation, with a minor semiannual component with the highs shifting toward the wintertime. We also found that the durations of the December and June solstice seasons in terms of ∑O/N(2) are highly variable with longitude. Our hypothesis is that ion-neutral collisional heating in the equatorial ionization anomaly region, ion drag, and auroral Joule heating play substantial roles in this longitudinal dependency. Finally, the rate of change in ∑O/N(2) from one solstice season to the other is dependent on latitude, with more dramatic changes at higher latitudes.

thermosphere↗

Online Rapid Analysis of Laser Heterodyne Radiometer (LHR) Data Using the Planetary Spectrum Generator (PSG)

One of the biggest challenges in developing scientific instruments is not just the build and testing of an instrument, but the method for processing the data and producing a consistent, well characterized data product that can be confidently used by the public and scientific community. Raw data products are frequently an array of numbers that are a read-out of voltages. The challenge is to convert these arrays into meaningful information as well as remove noise and interferences. Because this can be a tedious and time-consuming, the goal is to automate the process so that data ca be processed rapidly and be available in real-time for event monitoring. Here we present a rapid analysis method for Laser Heterodyne Radiometer (LHR) data that can be used to analyze data taken from a range of LHR observation modes (column, limb, etc.). This online tool uses the versatile Planetary Spectrum Generator (PSG) and allows LHR users to quickly analyze their own data using a NASA Goddard Space Flight Center (GSFC) monitored capability to ensure quality and reproducibility in the data products. Background: Development of a miniaturized LHR (mini-LHR) as a ground instrument for measuring carbon dioxide (CO 2 ) and methane (CH 4 ) in the atmospheric column started in 2009 with the commercial availability of distributive feedback lasers (DFB) in wavelengths that could measure absorption of gases in the near-IR. As new DFB lasers, detectors and hardware emerged at different wavelengths, additional gases were added to the capability. The mini-LHR was adapted into an occultation-viewing CubeSat with Lawrence Livermore National Laboratory (LLNL) for observing CO 2 , CH 4 , and H 2 O in the limb and was launched in 2019. Other versions of the LHR technology have been designed for observation of water vapor in the lunar exosphere as well as observations of trace gases in planetary atmospheres and plumes from icy moons. The PSG is an online tool developed at GSFC that can be used for synthesizing Earth and planetary spectra (atmospheres and surfaces) over a broad range of wavelengths (0.1 μm to 100 mm) for any observatory, orbiter or lander. Spectra are simulated by combining several state-of-the-art radiative transfer models, spectroscopic databases, planetary databases, as well as modern-era retrospective analysis for research and applications, version 2 (MERRA-2) data set which provides meteorological inputs such as modeled surface pressure for calculating dry-air columns.

Emily Wilson↗

Probing for Evidence of Plumes on Europa With HST/STIS

Roth et al. (2014a) reported evidence for plumes of water venting from a southern high latitude region on Europa: spectroscopic detection of off-limb line emission from the dissociation products of water. Here, we present Hubble Space Telescope direct images of Europa in the far-ultraviolet (FUV) as it transited the smooth face of Jupiter to measure absorption from gas or aerosols beyond the Europa limb. Out of 10 observations, we found 3 in which plume activity could be implicated. Two observations showed statistically significant features at latitudes similar to Roth et al., and the third at a more equatorial location. We consider potential systematic effects that might influence the statistical analysis and create artifacts, and are unable to find any that can definitively explain the features, although there are reasons to be cautious. If the apparent absorption features are real, the magnitude of implied outgassing is similar to that of the Roth et al. feature; however, the apparent activity appears more frequently in our data.

Planets and satellites↗

Chapter 10 - Remote Sensing Measurements of Aerosol Properties

Satellite instruments have proven especially capable at monitoring the quantity of airborne particles in columns of atmosphere, globally. This chapter describes the principles of satellite measurements and retrieval algorithms, and surveys current instruments and their capabilities. We outline the issues associated with retrieval algorithms, such as surface characterization and aerosol proximity to clouds, and the challenges with interpretation of the results. The relationship between measured aerosol properties and climate-relevant aerosol properties simulated in models is outlined, as well as how measurements are used to evaluate models. Most space-based aerosol instruments are passive sensors that measure reflected sunlight at multiple wavelengths, some at multiple viewing angles. A few are active sensors that send out their own laser light and measure the returned signal. Except when clouds are present, the excess amount of light scattered back to space, beyond that expected from the surface and atmospheric gas, is attributed to aerosol. Satellite measurements are used in many ways in aerosol research. They often provide the only method for monitoring hazardous phenomena such as major wildfire and volcanic eruption plumes, especially in remote areas. Stable, long-term, near-global-scale satellite data records make it possible to identify regional and global aerosol trends. Aerosol radiative effects on climate can be quantified on a near-global scale and used to estimate the strength of aerosol–radiation and aerosol–cloud interactions as well as to evaluate climate model simulations of these interactions. Aerosol-type mapping from satellite imagery is helpful for source attribution, model validation, and to constrain particle light-absorption properties that are essential for radiative forcing calculations. The range of aerosol properties retrieved from satellite observations has grown considerably since the first global estimates of aerosol optical depth (τ a) over ocean were made in the late 1970s. Methods for retrieving particle size and light-absorption properties were explored in the 1990s using multispectral, multi-angle observations, and polarization in visible and near-infrared wavelengths. Sensitivity to particle light absorption, primarily from black or brown carbon content, improved with the inclusion of UV channels, and sensitivity to very thin aerosol layers in the upper troposphere and lower stratosphere was advanced with the use of limb-sounding instruments and active sensors. There are limitations to every measurement technique, including satellite aerosol remote sensing. For wide-swath, passive instruments, aerosol retrievals near clouds can present substantial challenges as far as 15 km away due to cloud-scattered light contaminating the signal. In nearly all cases, retrievals over bright snow and ice surfaces are precluded because surface reflectance uncertainties can overwhelm the aerosol signal. Similarly, meteorological cloud is identified and masked out where possible. Data from passive sensors also lack vertical resolution except those that view toward the limb or where multi-angle imagery is acquired over plumes from wildfires, erupting volcanoes, and wind-blown dust. Yet, passive sensors provide vastly more coverage than the active instruments that mitigate these issues. Particle microphysical information is qualitative from all remote sensing techniques, relying on proxies to infer particle composition, hygroscopicity, and the amount of light-absorbing material. Further, particles smaller than about 200 nm diameter cannot be distinguished from atmospheric gas molecules with remote sensing, which hinders studies of cloud condensation nuclei and their effects on clouds. Most satellite instruments dedicated to aerosol observations are in low-Earth, near-polar, sun-synchronous orbits, which means they cross the equator at the same local time each day. Most are set on cycles that repeat approximately every 16 days, which makes it difficult to monitor aerosol evolution locally. Geostationary satellites make it possible to observe changes occurring from minutes to hours over regions up to 8000 km in size, but lack coverage of high latitudes, and often provide more limited constraints on aerosol properties. Ground-truth data are vital for satellite aerosol-retrieval validation. The AErosol RObotic NETwork (AERONET) of sun photometers was created in 1993 and has become an established global network of over 350 instruments for validating satellite measurements. The network, as well as global networks of ground-based lidars, solar flux radiometers and other sun photometers, are widely used for evaluating global satellite retrievals and model simulations. NASA's Earth Observing System (EOS) program beginning in 1999 led to improvements in reliability, spatial resolution, and spectral resolution (and hence, to improved particle size discrimination and light absorption properties). Satellite payloads include advanced broad-swath and multi-angle imagers, along with the first space-based active sensor focused largely on long-term aerosol monitoring. Since about 2002, Europe's SENTINEL and operational meteorological satellite fleets are also providing sustained aerosol observations, with planned continuation until at least 2030. Satellite remote sensing instruments offer valuable data for evaluating aerosol representations in global climate models. They have been used to assess aerosol optical and physical properties, trends and distributions, and are applied increasingly as direct model constraints in data assimilation to create global aerosol reanalysis products. Aerosol optical depth is the most common quantity adopted for routine model evaluation, including multiwavelength data to loosely constrain particle-size distributions. These evaluations of multiple models have revealed general biases in their regional aerosol amounts and seasonal patterns of transport and removal. Although satellite measurements have near-global coverage, substantial errors can be introduced into the model observation comparison unless attention is paid to spatial and temporal collocation, cloud screening, subgrid-scale variability, and measurement uncertainties that vary with retrieval conditions.

aerosol properties↗

Effect of the Heliospheric State on CME Evolution

The culmination of solar cycle 24 by the end of 2019 has created the opportunity to compare the differing properties of coronal mass ejections (CMEs) between two whole solar cycles: solar cycle 23 (SC 23) and solar cycle 24 (SC 24). We report on the width evolution of limb CMEs in SCs 23 and 24 in order to test the suggestion by Gopalswamy et al. that CME flux ropes attain pressure balance at larger heliocentric distances in SC 24. We measure CME width as a function of heliocentric distance for a significantly large number of limb CMEs (∼1000) and determine the distances where the CMEs reach constant width in each cycle. We introduced a new parameter, the transition height (hc) of a CME, defined as the critical heliocentric distance beyond which the CME width stabilizes to a quasi-constant value. Cycle and phase-to-phase comparisons are based on this new parameter. We find that the average value of hc in SC 24 is 62% higher than that in SC 23. SC 24 CMEs attain their peak width at larger distances from the Sun than SC 23 CMEs do. The enhanced transition height in SC 24 is new observational ratification of the anomalous expansion. The anomalous expansion of SC 24 CMEs, which is caused by the weak state of the heliosphere, accounts for the larger heliocentric distance where the pressure balance between CME flux rope and the ambient medium is attained.

Solar coronal mass ejections↗

Arctic Biogeochemical and Optical Properties of Dissolved Organic Matter Across River to Sea Gradients

Arctic landscapes are warming and becoming wetter due to changes in precipitation and the timing of snowmelt which consequently alters seasonal runoff and river discharge patterns. These changes in hydrology lead to increased mobilization and transport of terrestrial dissolved organic matter (DOM) to Arctic coastal seas where significant impacts on biogeochemical cycling can occur. Here, we present measurements of dissolved organic carbon (DOC) and chromophoric DOM (CDOM) in the Yukon River-to-Bering Sea system and two river plumes on the Alaska North Slope which flow into the Beaufort Sea. Our sampling characterized optical and biogeochemical properties of DOM during high and low river discharge periods for the Yukon River-Bering Sea system. The average DOC concentration at the multiple Yukon River mouths ranged from a high of 10.36 mg C L-1 during the ascending limb of the 2019 freshet (late May), 6.4 mg C L-1 during the descending limb of the 2019 freshet (late June), and a low of 3.86 mg C L-1 during low river discharge in August 2018. CDOM absorption coefficient at 412 nm (aCDOM(412)) averaged 8.23 m-1, 5.07 m-1, and 1.9 m-1, respectively. Several approaches to model DOC concentration based on its relationship with CDOM properties demonstrated cross-system seasonal and spatial robustness for these Arctic coastal systems despite spanning an order of magnitude decrease in DOC concentration from the lower Yukon River to the Northern Bering Sea as well as the North Slope systems. “Snapshot” fluxes of DOC and CDOM across the Yukon River Delta to Norton Sound were calculated from our measurements and modeled water fluxes forced with upstream USGS river gauge data. Our findings suggest that during high river flow, DOM reaches the delta largely unaltered by inputs or physical and biogeochemical processing and that the transformations of Yukon River DOM largely occur in the plume. However, during low summer discharge, multiple processes including local precipitation events, microbial decomposition, photochemistry, and likely others can alter the DOM properties within the lower Yukon River and Delta prior to flowing into Norton Sound.

Arctic↗

Validation of OMPS LP Ozone Profile Retrievals Using Solar Occultation Satellite Measurements

The OMPS Limb Profiler (OMPS LP) satellite instrument, launched in October 2011, performs limb measurements of scattered solar radiation in the ultraviolet and visible wavelengths, which allow for the retrieval of ozone profiles from the top of clouds up to 55km. In this study we utilize ozone retrievals from two solar occultation satellite instruments, SAGE III/ISS and ACE-FTS, to validate OMPS LP profile measurements processed with the new NASA GSFC version 2.6 retrieval algorithm. OMPS LP started operational observations in April 2012, whereas ACE-FTS observations started in February 2004, therefore, there are currently 12 years of data overlap to exploit for validation. SAGE III/ISS observations started in June 2017, which provides 7 years of data overlap with OMPS LP. The OMPS LP is a solar scattering instrument that makes observations in the sunlit portion of the Earth, whilst ACE-FTS and SAGE III/ISS are solar occultation instruments that measure ozone only at sunrise and sunset. To account for these differences in measurement times we use the Goddard Diurnal Ozone Climatology (GDOC). Diurnal adjustments using this climatology have been shown to help reduce biases above 30 km. Our analysis shows that biases between OMPS LP v2.6, ACE-FTS, and SAGE III/ISS are <10% between 18 and 45 km, and increase above and below these altitudes, which are comparable to the previous version of OMPS LP ozone retrievals (v2.5). The vertical patterns of the differences are similar across different latitudes and seasons, with larger seasonal variations observed in the Northern Hemisphere.

Atmospheric Science↗

Comparative Analysis of Type III Radio Bursts and Solar Flares: Spatial Localization and Correlation with Solar Flare Intensity

We present a comprehensive study of type III radio bursts and their association with solar flares of magnitude M1.0 and larger, as observed by four widely separated spacecraft (Parker Solar Probe, Solar Orbiter, STEREO-A, and Wind). Our main focus is the introduction and validation of two methods for localizing radio bursts using the available multispacecraft data. The first method utilizes intensity fitting with a circular Gaussian distribution, while the second method is based on the time arrival of radio bursts. We demonstrate the effectiveness of these methods through the analysis of a single type III burst event and compare their results with the traditional radio triangulation technique. Furthermore, we conduct a statistical study of 17 type III bursts associated with M- and X-class solar flares in years 2020–2022. Our findings suggest a possible correlation between solar flare intensities and longitudes, with east limb flares tending to be weaker than west limb flares. We also observe a systematic drift of radio burst longitudes toward the east, potentially explained by a poleward component of the local density gradient. Our results suggest a strong correlation between solar flare intensities and radio burst properties, enhancing our understanding of the relationship between solar flares and type III radio bursts.

Radio astronomy↗

CREST: a Climate Data Record of Stratospheric Aerosols

Climate-related studies need information about the distribution of stratospheric aerosols, which influence the energy balance of the Earth’s atmosphere. In this work, we present a merged dataset of vertically resolved stratospheric aerosol extinction coefficients, which is derived using data from six limb and occultation satellite instruments: SAGE (Stratospheric Aerosol and Gas Experiment) II on ERBS (Earth Radiation Budget Satellite), GOMOS (Global Ozone Monitoring by Occultation of Stars) and SCIAMACHY (Scanning Imaging Spectrometer for Atmospheric Chartography) on Envisat, OSIRIS (Optical Spectrograph and InfraRed Imaging System) on Odin, OMPS (Ozone Monitor Profiling Suite Limb Profiler) on Suomi NPP, and SAGE III on the ISS (International Space Station). The merging of aerosol profiles is performed via the transformation of the aerosol datasets from individual satellite instruments to the same wavelength (750 nm) and their de-biasing and homogenization by adjusting the seasonal cycles. After such homogenization, the data from individual satellite instruments are in good agreement. The merged aerosol extinction coefficient is computed as the median of the adjusted data from the individual instruments. The merged time series of vertically resolved monthly mean aerosol extinction coefficients at 750 nm is provided in 10° latitudinal bins from 90° S to 90° N, in the altitude range from 8.5 to 39.5 km. The time series of the stratospheric aerosol optical depth (SAOD) is created via the integration of aerosol extinction profiles from the tropopause to 39.5 km; it is also provided as monthly mean data in 10° latitudinal bins. The created aerosol climate record covers the period from October 1984 until December 2023, and it is intended to be extended in the future. The merged CREST aerosol dataset (v2) is available at https://doi.org/10.57707/fmib2share.dfe14351fd8548bcaca3c2956b17f665 (Sofieva et al., 2024a). It can be used in various climate-related studies.

Viktoria F Sofieva↗

The Aeolus-Earth DWTS Heliophysics Mission

The Aeolus-Earth Mission (DWTS-Helio) is a recently selected NASA Heliophysics investigation that will apply the innovative Doppler Wind Temperature Sounder (DWTS) technique to the Space Atmosphere Interaction Region (SAIR) at ~105-180 km. The technique, invented by Gordley & Marshall (2011), applies the Doppler Scanning with Gas Filter (DSGF) technique using a cryo-cooled MWIR radiometer to view the limb of the atmosphere from LEO (orbital velocity creates the Doppler shifts required by the technique). For this implementation of DWTS, a Nitric Oxide (NO) low pressure gas cell is used. The limb of the atmosphere is observed from a spacecraft at orbital velocity, and as an observed air volume passes through the field of view, this velocity creates a set of Doppler-shifted images. These images are used to create Doppler Integrated Pass (DIP) signals, from which atmospheric temperature and wind profiles are extracted (it may be considered a converse of the successful in-flight calibration of gas cells used for the HALOE instrument). The technique is relative, removing the need for absolute radiances, and the signal-to-noise ratio for this technique is high, resulting in good measurement precision. Different gas cells can be used to create different altitude coverage and may be combined to measure a more continuous altitude range. For example, using a NO cell captures the lower atmosphere from 30-50km as well as the SAIR, while using the 13 isotopologue of CO2 would capture 50-120km. Due to the desired data volume as well as power and thermal considerations, this initial Aeolus-Earth flight will be more suited for a ‘hosted’ payload on an Orbital Maneuvering Vehicle platform instead of the ‘free-flyer’ option originally investigated. Lastly, the technique is sufficiently powerful that a two-channel system could produce full Mars atmosphere data not currently possible.

DWTS↗

High Dexterity Robotics for Safety and Emergency Response - 17104

Recently, significant advances in robotics have led to increased use in industrial and military applications. For example, the military has used explosive ordnance disposal (EOD) robots to enable responders to remotely investigate hazardous environments. While EOD robots have saved many lives, their utility is hampered by: 1) limited ability to manipulate complex objects and mechanisms (e.g. open a car door, operate power tools or turn valves), and 2) the requirement for significant operator training using joystick-type interfaces. Most robots today have simplistic manipulators and cannot easily operate in environments designed for humans as evidenced by the recent Amazon Picking Challenge and the DARPA Robotics Challenge. Simple tasks that humans perform easily, such as picking up objects or operating a cutting tool, require customized rigs that are expensive and time-consuming to use. The specialized nature of these robots limits their utility in highly unstructured environments, for example during emergency situations where a robot may need to be rapidly re-purposed for an unanticipated situation (i.e. the Fukushima nuclear disaster). Robots are needed that can perform complex human-like tasks and are easy to use for everyday and emergency tasks. In 2005 the Defense Advanced Research Projects Agency (DARPA) initiated the Revolutionizing Prosthetics (RP) Program with the goal of creating prosthetics as capable as the human arm and a human-machine interface enabling highly intuitive operation. The Johns Hopkins University Applied Physics Laboratory (JHU/APL) created the Modular Prosthetic Limb (MPL), originally developed for amputees and paralyzed individuals as part of the RP Program, to replicate the capability of the human hand and arm to the extent technologically possible. With 26 joints and over 180 sensors, it is one of the most sophisticated and fully integrated robotic arms in the world. We have also demonstrated human-machine interface techniques that are highly intuitive requiring minimal training. While the MPL was originally designed as a prosthetic, it has also been incorporated into mobile robotic systems to project human capability. Using tele-operation, we have demonstrated the ability to perform dual-arm remote operations in complex environments. For nuclear facilities, high dexterity robots combined with tele-operation offer the potential to enhance worker safety, productivity and quality. Safety enhancements include enabling remote operation in hazardous environments, remote handling of heavy or dangerous materials, and elimination of injury due to repetitive motions. Because the MPL is designed to function like a human limb, the robot can work in environments designed for humans with limited need for specialized tools. When used for routine operations, it can also maintain a level of familiarity and confidence that effectively accomplishes reinforcement training for use in emergency situations, unlike a specialized robot that might sit unused for months or years at a time. In August 2016 we demonstrated the use of the MPL at the Portsmouth Gaseous Diffusion Plant in Piketon, Ohio. Two robotic platform technologies were demonstrated to familiarize the DOE Emergency Management's (EM) workforce on the potential benefits of this technology. Here we present the results of those efforts, highlight the lessons learned during 'EM Week,' and outline potential future developments that could further advance application of these technologies to enhance worker safety. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Telerobotic Control of Dexterous Dual-Arm Robots for D and D Operations - 18622

Robotic systems hold the potential to significantly reduce exposure of workers to hazardous environments such as in the deactivation and decommissioning (D and D) of nuclear facilities. Our goal is to enable an operator with minimal training to easily control a remote dual-arm robot to perform demolition tasks with hand tools. We propose a system that combines semi-autonomous coordination of the robot's arms with an intuitive operator interface based on virtual reality (VR) technology. A limb coordination system enables independent control of the robot arms, as well as coupled motion required to hold and manipulate rigid bodies such as reciprocating saws, angle grinders and crow bars. Using a VR head mounted display and stereo video from the robot for situational awareness and tracked VR hand controllers to command robot arm movement, an operator will be able to walk up to the control console, pick up the controllers, engage the manipulators, fly the grippers, grasp a tool with one or both robot arms and easily move them in unison to perform tasks. We present preliminary results using simulation and a physical dual-arm platform based on the Johns Hopkins University Applied Physics Laboratory's Modular Prosthetic Limb, an anthropomorphic device that provides hyper-dexterous human-like manipulation capabilities. Anticipated benefits of the robotic system for D and D operations include improved situational awareness, increased mission complexity, and reduced operator training time, workload, and task execution times. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Staff Radiation Doses to the Lower Extremities in Interventional Radiology

The purpose of this study was to investigate the radiation doses to the lower extremities in interventional radiology suites and evaluate the benefit of installation of protective lead shielding. After an alarmingly increased dose to the lower extremity in a preliminary study, nine interventional radiologists wore thermoluminescent dosimeters (TLDs) just above the ankle, over a 4-week period. Two different interventional suites were used with Siemens undercouch fluoroscopy systems. A range of procedures was carried out including angiography, embolization, venous access, drainages, and biopsies. A second identical 4-week study was then performed after the installation of a 0.25-mm lead curtain on the working side of each interventional table. Equivalent doses for all nine radiologists were calculated. One radiologist exceeded the monthly dose limit for a Category B worker (12.5 mSv) for both lower extremities before lead shield placement but not afterward. The averages of both lower extremities showed a statistically significant dose reduction of 64% (p < 0.004) after shield placement. The left lower extremity received a higher dose than the right, 6.49 vs. 4.57 mSv, an increase by a factor of 1.42. Interventional radiology is here to stay but the benefits of interventional radiology should never distract us from the important issue of radiation protection. All possible measures should be taken to optimize working conditions for staff. This study showed a significant lower limb extremity dose reduction with the use of a protective lead curtain. This curtain should be used routinely on all C-arm interventional radiologic equipment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Manual Aspiration Thrombectomy with Stent Placement: Rapid and Effective Treatment for Phlegmasia Cerulea Dolens with Impending Venous Gangrene

Phlegmasia cerulea dolens is an uncommon but potentially life-threatening complication of acute deep vein thrombosis. It is an emergency and delay in treatment may cause death or loss of the patient's limb. Surgical thrombectomy is the recommended treatment in venous gangrene. Catheter-directed intrathrombus thrombolysis has been reported as successful, but it may require a lengthy infusion. Manual aspiration thrombectomy may clear the entire thrombus with no need for thrombolytic administration and provide rapid and effective treatment for patients with phlegmasia cerulea dolens with impending venous gangrene.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy and Safety of the Angioseal Vascular Closure Device Post Antegrade Puncture

In this study, the efficacy and safety of the Angioseal vascular closure device post antegrade puncture of the common femoral artery (CFA) for lower limb vascular interventional procedures are evaluated. A retrospective analysis of the medical records of 60 consecutive patients who were referred for interventional procedures in the superficial femoral artery (SFA) or popliteal artery (popl. art.) was performed. Antegrade puncture was successfully performed in 58 of 60 patients (96.6%). Indications included right SFA angioplasty (n = 35), left SFA angioplasty (n = 17), right popl. art. angioplasty (n = 5), and left popl. art. angioplasty (n = 1). Hemostasis was achieved by, on an intention-to-treat basis, the Angioseal vascular closure device in 46 patients and manual compression in 12 patients. Manual compression was used instead of Angioseal because of severe calcified arterial wall plaques (n = 7), failed deployment of the Angioseal (n = 4), and left SFA dissection (n = 1). There were no major recorded complications in the Angioseal group despite the use of antiplatelet or anticoagulant medications. Twenty-three (50%) of the patients in the Angioseal group were discharged within 24 h. Thirty-seven of the 46 patients who received an Angioseal device had undergone a previous ipsilateral CFA puncture (time range, 2 days to 56 months; mean, 6.2 months). Nine of these patients had undergone ipsilateral Angioseal deployment in the previous 3 months. We conclude that the Angioseal vascular closure device is a safe and efficient means of achieving hemostasis post antegrade puncture.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-Expandable Stent Placement in Infrapopliteal Arteries After Unsuccessful Angioplasty Failure: One-Year Follow-up

The purpose of this prospective study was to evaluate whether stent placement in infrapopliteal arteries is helpful in failed percutaneous transluminal angioplasty (PTA). Infrapopliteal PTA was performed in 70 arteries of 66 patients with chronic critical lower limb ischemia. The group comprised 55 males and 11 females, with an average age of 63.4 (range, 42-82) years. Diabetes mellitus was present in 92.4% of patients. Only the palpable anterior tibial and posterior tibial arteries were evaluated. Stents (Xpert stent; Abbot Vascular, Redwood City, CA, USA) were placed in 16 arteries where PTA was not successful (the failure was defined as residual stenosis >30% after PTA). In 54 arteries simple PTA was performed and was technically successful. Twenty-four nondilated arteries with no significant stenosis served as a comparison group. The 12-month patency rate was evaluated according to a combination of palpation and Doppler ultrasound. In all cases stent placement restored the flow in the artery immediately after unsuccessful PTA. Twelve-month follow-up showed a patency rate of 82% in the PTA group, 78% in the stent group, and 69% in the comparison group. We conclude that stent placement in the case of unsuccessful infrapopliteal PTA changed technical failure to success and restored flow in the dilated artery. At 12-month follow-up the patency rate of infrapopliteal arteries stented for PTA failure did not differ significantly either from nonstented arteries with an optimal PTA result or from a comparison group of nonintervened arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗