Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Integration of a DER Management System in Riverside. Final report

The tasks in this project covered various aspects, including algorithm development, algorithm integration into a commercial Active Network Management (ANM) platform, hardware-in-the-loop (HIL) testing in an industry-standard testing platform, pilot demonstration in Riverside, California, and also cost and benefit analysis. The DERMS platform in this project can host different algorithms developed on different platforms (e.g., MATLAB and Python) and it can interact with different hardware devices (e.g., different PV inverters, battery inverters, and different sensors). The DER control solution are based on an advanced model-free, layered, and clustered DER control paradigm. At the core of the DER control algorithms was the concept of Extremum Seeking (ES), which is a model-free probing-based control technique. The ES-based control algorithms were tested on major real-world inverters; both individually and in a cluster. It was shown that even legacy equipment (or when paired with a few additional advanced equipment) can support such advanced control. The monitoring algorithms utilize a heterogeneous set of legacy and advanced sensor measurements, such as behind-the-meter DER sensors, distribution-level Phase Measurement Units, distribution-substation Supervisory Control and Data Acquisition (SCADA), and line current sensors, with their limited availability; in order to infer practical network conditions. Sensor data are utilized to achieve resource forecasting, phase identification, and distribution system state estimation. The technology that was developed and demonstrated in this project could be transformational to utilities, including the smaller municipal utilities such as in Riverside, which may not have the resources to deploy advanced distribution system and DERMS solutions in order to support high penetration of solar power integration. This project created a real-world prototype to provide utilities with an assessment of smart grid monitoring and control technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Cybersecurity, Situational Awareness and Resilience in Distribution Grids with High Penetration of Photovoltaics (CARE-PV) (Final Report)

Since legacy distribution systems have very limited visibility beyond the substation, high penetration of PV at the grid edge presents some unique operational challenges. One approach to address these challenges is to use information from advanced metering infrastructure (AMI) and µPMUs. However, exploiting this information is impacted by a number of factors, including multi-timescale measurements, volume of data generated, communication network impairments (e.g., information loss and latency) and susceptibility to cyber-attacks. Therefore, one of the critical tasks involved in the management of a distribution grid is to develop complete situational awareness by integrating cyber-security mechanisms with state estimation strategies and leveraging this situational awareness to assure energy services at strategic locations while exploiting AMI/PV inverter/ µPMU data. This CARE-PV project addresses the fundamental challenges in situational awareness and resilience to cyber and physical vectors by exploiting the synergy between innovative modeling, estimation, data analytics, testing and validation using smart PV inverters designed at K-State and facilities at NREL. Specifically, the project involved the development, testing and validation of the following novel enabling technologies: (Thrust 1) Resilience to cyber vectors that impact data integrity was addressed via a two-level defense strategy that combines cyber intrusion detection using self-learning, cooperative smart PV inverters, and a novel moving target defense framework to combat data integrity attacks. (Thrust 2) Resilience to cyber-physical vectors that impact situational awareness by limiting data availability was addressed via novel centralized and decentralized, sparsity-based static and dynamic state estimation approaches that enhance observability even when the underlying system is unobservable. (Thrust 3) Leveraging a unique probabilistic sensitivity analysis approach accompanied by one-of-a-kind dominant influencer set computation, the vulnerability of critical infrastructure at strategic locations was evaluated so that proactive PV-based control strategies can be used to support operations under normal/outage scenarios. These CARE-PV project innovations were demonstrated on both small-scale IEEE and larger utility-scale testbeds (Thrust 4). Feedback from Industry Advisory Board members was used to formulate a commercialization pathway for a subset of CARE-PV technologies. These CARE-PV technologies will ultimately lead to reliable and secure, large-scale integration of renewable energy and mitigate the risk of energy disruption resulting from cyber incidents and other emerging threats within the energy environment.

14 SOLAR ENERGY↗

Uninterruptible Power Supply Systems, UTrain Course 58423 [Slides]

Identify the principles of operation of uninterruptible power supply (UPS) systems, focusing on double conversion and offline/standby/backup types. The traditional UPS is now referred to as a “double conversion” UPS. The AC input power is rectified into DC. The DC feeds an inverter which provides the AC output. The DC bus is also connected to batteries. It is called double conversion because the first conversion is from AC to DC and the second conversion is from DC to AC. The inverter creates the output waveform to match the bypass input. Because of this, the static bypass switch may be switched between inverter and bypass seamlessly.

42 ENGINEERING↗

DOE 10658 Project Sensitivity-Driven Wide Area Protection (SWAP) Coordination Tools for IBRs

Utilities have seen a rapid increase in solar, wind, and battery energy storage systems that interconnect to their electric system through inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well-known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protects the inverter’s sensitive power electronics devices from damage from conditions such as overcurrent. This results in a low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufacturers and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of focusing on one issue, this report looks broadly at all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspectives from different utility SMEs via questionnaire, the report summarizes the gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Internship Work Report

I worked on two projects during my summer internship at Sandia. My official title was “Intern - Mission Tech Electrical Eng./Computer Eng.- R&D Undergraduate Summer.” I worked at the central location, which is Albuquerque, New Mexico. The department you are placed in at Sandia doesn’t always correspond to the people you will be working with. For example, I only directly worked with one person from my department this summer. On one of my projects, I worked with a diverse team of engineers from many different departments. On my other project, I mainly worked with two departments, as the project had two distinct parts. As mentioned earlier, I worked on two projects during my summer at Sandia. The first project focused on a lightweight embedded controller in an advanced FPGA System-on-Chip for radar signal processing applications. The term “controller” refers to a hardware device that directs the flow of data between two entities. An FPGA is a reprogrammable integrated circuit (as opposed to an integrated circuit with one purpose). An FPGA was used on this project so in order to protype various ideas for our System-on-Chip. My role on the project was to implement designs on the fabric of the FPGA and design a state machine (written in C) for the processor. My second project was also heavily involved with embedded systems but had a different application. It focused on using a Newton-Raphson control algorithm to stabilize an inverted pendulum using a novel microcontroller. The pendulum dynamics were derived, and it was successfully simulated in MATLAB. I worked on integrating the microcontroller with the inverted pendulum machinery, and converting the Newton-Raphson control algorithm from MATLAB into C. The inverted pendulum was successfully stabilized using a simple PID controller and industry-standard microcontroller. The project is still ongoing, and the team is gearing up for more tests using the novel Newton-Raphson control algorithm and novel microcontroller

42 ENGINEERING↗

Controlling Interfacial Charge Separation Energetics and Kinetics

The overall goal is to probe electron transfer kinetics of the Marcus inverted region at interfaces. This project specifically uses a dye‐semiconductor interface with a reversible electron transfer reagent in solution where the semiconductor conduction band and electron transfer reagent ideally have a potential energy difference firmly within the Marcus inverted region. The goals of this project are: (Goal 1) Identify dye design elements that give dyes with low energy ground‐state oxidation potentials while retaining desirable electron transfer kinetics at the semiconductor interface. (Goal 2) Identify dye designs with excited‐state oxidation potentials set to fixed energies through molecular design while the dye ground‐state oxidation potentials are varied to allow for the evaluation of varied electron transfer reagents/redox shuttles (RS) with different free energies for electron transfer. (Goal 3) Within the context of the functionality identified in goals 1 and 2, goal 3 seeks to design dyes with features maximizing charge carrier lifetimes by minimizing recombination losses at metal oxide interfaces with high voltage systems. (Goal 4) Probe electron transfer kinetics in a high voltage‐dye sensitized solar cell with both the oxidized dye and RS firmly within the Marcus inverted region with regard to the TiO2 CB. (Goal 5) Identify tailored sensitizer/redox shuttle pairs with desirable electron transfer kinetics in defined spectral regions capable of “banding off” incident solar irradiation to give high voltage multijunction systems capable of exceeding the Shockley‐Queisser limit and powering catalytic processes.

14 SOLAR ENERGY↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

World’s First Vertical GaN based High Power (200 kW) Multi-level Traction Electric Drive Design

Vertical GaN (vGaN) technology leverages a fully conductive 3D semiconductor structure, enabling superior power density compared to GaN-on-Si and other wide bandgap devices. It offers a pathway to surpass cost and efficiency limitations of Si and SiC devices in traction applications. However, scaling for high-voltage, high-power systems remains challenging. This paper presents the design of an 800V, 200kW traction inverter utilizing vertical GaN devices. The inverter achieves ultra-high efficiency (> 99.5%) through advanced power module integration and employs multilevel neutral-point-less X-type (NPL.X) inverter topology to ensure optimal traction drive system performance. These innovations demonstrate the potential of vGaN for next￾generation electric propulsion systems.

Alam, Khorshed [General Motors LLC, Detroit, MI (U↗

Distributed Transient Safety Verification via Robust Control Invariant Sets: A Microgrid Application

Modern safety-critical energy infrastructures are increasingly operated in a hierarchical and modular control framework which allows for limited data exchange between the modules. In this context, it is important for each module to synthesize and communicate constraints on the values of exchanged information in order to assure system-wide safety. To ensure transient safety in inverter-based microgrids, we develop a set invariance-based distributed safety verification algorithm for each inverter module. Applying Nagumo's invariance condition, we construct a robust polynomial optimization problem to jointly search for safety-admissible set of control set-points and design parameters, under allowable disturbances from neighbors. We use sum-of-squares (SOS) programming to solve the verification problem and we perform numerical simulations using grid-forming inverters to illustrate the algorithm.

Bouvier, Jean-Baptiste H.↗

INTEGRATE - Inverse Network Transformations for Efficient Generation of Robust Airfoil and Turbine Enhancements

The INTEGRATE (Inverse Network Transformations for Efficient Generation of Robust Airfoil and Turbine Enhancements) project is developing a new inverse-design capability for the aerodynamic design of wind turbine rotors using invertible neural networks. This AI-based design technology can capture complex non-linear aerodynamic effects while being 100 times faster than design approaches based on computational fluid dynamics. This project enables innovation in wind turbine design by accelerating time to market through higher-accuracy early design iterations to reduce the levelized cost of energy. INVERTIBLE NEURAL NETWORKS Researchers are leveraging a specialized invertible neural network (INN) architecture along with the novel dimension-reduction methods and airfoil/blade shape representations developed by collaborators at the National Institute of Standards and Technology (NIST) learns complex relationships between airfoil or blade shapes and their associated aerodynamic and structural properties. This INN architecture will accelerate designs by providing a cost-effective alternative to current industrial aerodynamic design processes, including: - Blade element momentum (BEM) theory models: limited effectiveness for design of offshore rotors with large, flexible blades where nonlinear aerodynamic effects dominate - Direct design using computational fluid dynamics (CFD): cost-prohibitive - Inverse-design models based on deep neural networks (DNNs): attractive alternative to CFD for 2D design problems, but quickly overwhelmed by the increased number of design variables in 3D problems AUTOMATED COMPUTATIONAL FLUID DYNAMICS FOR TRAINING DATA GENERATION - MERCURY FRAMEWORK The INN is trained on data obtained using the University of Marylands (UMD) Mercury Framework, which has with robust automated mesh generation capabilities and advanced turbulence and transition models validated for wind energy applications. Mercury is a multi-mesh paradigm, heterogeneous CPU-GPU framework. The framework incorporates three flow solvers at UMD, 1) OverTURNS, a structured solver on CPUs, 2) HAMSTR, a line based unstructured solver on CPUs, and 3) GARFIELD, a structured solver on GPUs. The framework is based on Python, that is often used to wrap C or Fortran codes for interoperability with other solvers. Communication between multiple solvers is accomplished with a Topology Independent Overset Grid Assembler (TIOGA). NOVEL AIRFOIL SHAPE REPRESENTATIONS USING GRASSMAN SPACES We developed a novel representation of shapes which decouples affine-style deformations from a rich set of data-driven deformations over a submanifold of the Grassmannian. The Grassmannian representation as an analytic generative model, informed by a database of physically relevant airfoils, offers (i) a rich set of novel 2D airfoil deformations not previously captured in the data , (ii) improved low-dimensional parameter domain for inferential statistics informing design/manufacturing, and (iii) consistent 3D blade representation and perturbation over a sequence of nominal shapes. TECHNOLOGY TRANSFER DEMONSTRATION - COUPLING WITH NREL WISDEM Researchers have integrated the inverse-design tool for 2D airfoils (INN-Airfoil) into WISDEM (Wind Plant Integrated Systems Design and Engineering Model), a multidisciplinary design and optimization framework for assessing the cost of energy, as part of tech-transfer demonstration. The integration of INN-Airfoil into WISDEM allows for the design of airfoils along with the blades that meet the dynamic design constraints on cost of energy, annual energy production, and the capital costs. Through preliminary studies, researchers have shown that the coupled INN-Airfoil + WISDEM approach reduces the cost of energy by around 1% compared to the conventional design approach. This page will serve as a place to easily access all the publications from this work and the repositories for the software developed and released through this pr...

aerodynamics↗

Volt-Var Curve Reactive Power Control Requirements and Risks for Feeders with Distributed Roof-Top Photovoltaic Systems

The benefits and risks associated with Volt-Var Curve (VVC) control for management of voltages in electric feeders with distributed, roof-top photovoltaic (PV) can be defined using a stochastic hosting capacity analysis methodology. Although past work showed that a PV inverter’s reactive power can improve grid voltages for large PV installations, this study adds to the past research by evaluating the control method’s impact (both good and bad) when deployed throughout the feeder within small, distributed PV systems. The stochastic hosting capacity simulation effort iterated through hundreds of load and PV generation scenarios and various control types. The simulations also tested the impact of VVCs with tampered settings to understand the potential risks associated with a cyber-attack on all of the PV inverters scattered throughout a feeder. The simulation effort found that the VVC can have an insignificant role in managing the voltage when deployed in distributed roof-top PV inverters. This type of integration strategy will result in little to no harm when subjected to a successful cyber-attack that alters the VVC settings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The electrical power subsystem of the Pioneer F/G spacecraft.

The Pioneer F/G spacecraft is the first to use radioisotope thermoelectric generators (RTG's) for a long duration interplanetary mission. This paper describes the design of the spacecraft power subsystem which meets the unique requirements of such a mission. The primary power source consists of four SNAP 19 RTG's. The 4.2 volt dc outputs of the RTG's are inverted to higher voltage ac by four inverters which are connected in parallel at their outputs. A power control unit (PCU) regulates the ac output of the inverters such that the RTG's are operated at near maximum power voltage throughout the mission. The PCU also contains charge and discharge controls for a silver cadmium battery which supplements the RTG's if load requirements temporarily exceed RTG power output. Battery reliability is enhanced by overcharge and cell reversal protection electronics which are provided for each cell. Multiple, low voltage, regulated dc outputs which supply power to the spacecraft subsystems are provided by a central transformer-rectifier-filter unit (CTRF). The CTRF operates directly from the regulated ac bus.

Reppucci, G. M.↗

Local-time survey of plasma at low altitudes over the auroral zones.

Local-time survey of the low-energy proton and electron intensities precipitated into the earth's atmosphere over the auroral zones during periods of magnetic quiescence. This survey was constructed by selecting a typical individual satellite crossing of this region in each of eight local-time sectors from a large library of similar observations with the polar-orbiting satellite Injun 5. The trapping boundary for more-energetic electron intensities, E greater than 45 keV, was found to be a 'natural coordinate' for delineating the boundary between the two major types of lower-energy, 50 less than or equal to E less than or equal to 15,000 eV, electron precipitation commonly observed over the auroral zones at low altitudes. Poleward of this trapping boundary inverted 'V' electron precipitation bands are observed in all local-time sectors. These inverted 'V' electron bands in the evening and midnight sectors are typically more energetic and have greater latitudinal widths than their counterparts in the noon and morning sectors. In general, the main contributors to the electron energy influx into the earth's atmosphere over the auroral zones are the electron inverted 'V' precipitation poleward of the trapping boundary in late evening, the plasma-sheet electron intensities equatorward of this boundary in early morning, and both of these precipitation events near local midnight.

Frank, L. A.↗

Wind-powered asynchronous AC/DC/AC converter system

Two asynchronous ac/dc/ac systems are modelled that utilize wind power to drive a variable or constant hertz alternator. The first system employs a high power 60-hertz inverter tie to the large backup supply of the power company to either supplement them from wind energy, storage, or from a combination of both at a preset desired current; rectifier and inverter are identical and operate in either mode depending on the silicon control rectifier firing angle. The second system employs the same rectification but from a 60-hertz alternator arrangement; it provides mainly dc output, some sinusoidal 60-hertz from the wind bus and some high harmonic content 60-hertz from an 800-watt inverter.

Reitan, D. K.↗

Experimental investigation of the landing dynamics of three-legged spacecraft models

An experimental investigation was conducted to obtain accurate data from two three-legged spacecraft landing systems for purposes of validating current and future computer programs for legged landers. Two landing-gear systems were investigated: an inverted tripod system and a cantilever system. Tests were conducted for eight landing conditions chosen to obtain stability data, maximum loads, and maximum strokes for correlation with analytical results. Data from the two models are not directly comparable because of geometry and mass differences, but both are considered to be typical models of the respective landing-gear systems. Results indicate that maximum accelerations for both models, which occurred during a nearly flat landing on a horizontal surface, were nearly the same (approximately minus 18g). Maximum primary strut forces occurred for landings into a 20 deg slope and were 40 kiloNewtons (9000 lbf) and 47 kiloNewtons (10 500 lbf) for the inverted tripod and cantilever models, respectively; and maximum primary strut strokes for both models were 19 cm (7.4 in.). The inverted tripod model was slightly more stable than the cantilever model because of a larger ratio of footpad radius to center-of-gravity height.

Stubbs, S. M.↗

Research on spacecraft electrical power conversion

The steady state characteristics and starting behavior of some widely used self-oscillating magnetically coupled square wave inverters were studied and the development of LC-tuned square wave inverters is reported. An analysis on high amplitude voltage spikes which occur in dc-to-square-wave parallel converters shows the importance of various circuit parameters for inverter design and for the suppression of spikes. A computerized simulation of an inductor energy storage dc-to-dc converter with closed loop regulators and of a preregulating current step-up converter are detailed. Work continued on the computer aided design of two-winding energy storage dc-to-dc converters.

Wilson, T. G.↗

Aeroacoustic studies of coannular nozzles suitable for supersonic cruise aircraft applications

Research programs were conducted to investigate experimentally the aeroacoustic characteristics of scale model, inverted-velocity profile coannular nozzles. These programs include studies of unsuppressed configurations with and without center plugs over a variety of radius ratios and area ratios. Also included are suppressed configurations, the effect of ejectors, and some simulated flight effects. Unsuppressed inverted-velocity profile coannular nozzles seem to allow jet mixing noise compliance with present FAR-36 regulations when applied to supersonic cruise aircraft engine cycles. Simulated flight tests suggest that the aeroacoustic benefits of the inverted-velocity profile coannular nozzles would be maintained in flight.

Gutierrez, O.↗