Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

SU-C-18A-04: 3D Markerless Registration of Lung Based On Coherent Point Drift: Application in Image Guided Radiotherapy

Purpose: This study evaluated a new probabilistic non-rigid registration method called coherent point drift for real time 3D markerless registration of the lung motion during radiotherapy. Method: 4DCT image datasets Dir-lab (www.dir-lab.com) have been used for creating 3D boundary element model of the lungs. For the first step, the 3D surface of the lungs in respiration phases T0 and T50 were segmented and divided into a finite number of linear triangular elements. Each triangle is a two dimensional object which has three vertices (each vertex has three degree of freedom). One of the main features of the lungs motion is velocity coherence so the vertices that creating the mesh of the lungs should also have features and degree of freedom of lung structure. This means that the vertices close to each other tend to move coherently. In the next step, we implemented a probabilistic non-rigid registration method called coherent point drift to calculate nonlinear displacement of vertices between different expiratory phases. Results: The method has been applied to images of 10-patients in Dir-lab dataset. The normal distribution of vertices to the origin for each expiratory stage were calculated. The results shows that the maximum error of registration between different expiratory phases is less than 0.4 mm (0.38 SI, 0.33 mm AP, 0.29 mm RL direction). This method is a reliable method for calculating the vector of displacement, and the degrees of freedom (DOFs) of lung structure in radiotherapy. Conclusions: We evaluated a new 3D registration method for distribution set of vertices inside lungs mesh. In this technique, lungs motion considering velocity coherence are inserted as a penalty in regularization function. The results indicate that high registration accuracy is achievable with CPD. This method is helpful for calculating of displacement vector and analyzing possible physiological and anatomical changes during treatment.

60 APPLIED LIFE SCIENCES↗

SEARCHING FOR PLANET NINE WITH COADDED WISE AND NEOWISE-REACTIVATION IMAGES

A distant, as yet unseen ninth planet has been invoked to explain various observations of the outer solar system. While such a “Planet Nine,” if it exists, is most likely to be discovered via reflected light in the optical, it may emit much more strongly at 3−5 μm than simple blackbody predictions would suggest, depending on its atmospheric properties. As a result, Planet Nine may be detectable at 3.4 μm with the Wide-field Infrared Survey Explorer, but single exposures are too shallow except at relatively small distances (d{sub 9}≲430 au). We develop a method to search for Planet Nine far beyond the W1 single-exposure sensitivity, to distances as large as 800 au, using inertial coadds of W1 exposures binned into ∼1 day intervals. We apply our methodology to a ∼2000 square degree testbed sky region which overlaps a southern segment of Planet Nine’s anticipated orbital path. We do not detect a plausible Planet Nine candidate, but are able to derive a detailed completeness curve, ruling out its presence within the parameter space searched at W1 < 16.66 (90% completeness). Our method uses all publicly available W1 imaging, spanning 2010 January to 2015 December, and will become more sensitive with future NEOWISE-Reactivation releases of additional W1 exposures. We anticipate that our method will be applicable to the entire high Galactic latitude sky, and we will extend our search to that full footprint in the near future.

79 ASTRONOMY AND ASTROPHYSICS↗

Unpaired image translation to mitigate domain shift in liquid argon time projection chamber detector responses

Deep learning algorithms often are developed and trained on a training dataset and deployed on test datasets. Any systematic difference between the training and a test dataset may severely degrade the final algorithm performance on the test dataset—what is known as the domain shift problem . This issue is prevalent in many scientific domains where algorithms are trained on simulated data but applied to real-world datasets. Typically, the domain shift problem is solved through various domain adaptation (DA) methods. However, these methods are often tailored for a specific downstream task, such as classification or semantic segmentation, and may not easily generalize to different tasks. This work explores the feasibility of using an alternative way to solve the domain shift problem that is not specific to any downstream algorithm. The proposed approach relies on modern Unpaired Image-to-Image (UI2I) translation techniques, designed to find translations between different image domains in a fully unsupervised fashion. In this study, the approach is applied to a domain shift problem commonly encountered in Liquid Argon Time Projection Chamber (LArTPC) detector research when seeking a way to translate samples between two differently distributed LArTPC detector datasets deterministically. This translation allows for mapping real-world data into the simulated data domain where the downstream algorithms can be run with much less domain-shift-related performance degradation. Conversely, using the translation from the simulated data to a real-world domain can increase the realism of the simulated dataset and reduce the magnitude of any systematic uncertainties. To evaluate the quality of the translations, we use both pixel-wise metrics and a downstream task to measure the effectiveness of UI2I methods for mitigating the domain shift problem. We adapted several popular UI2I translation algorithms to work on scientific data and demonstrated the viability of these techniques for solving the domain shift problem with LArTPC detector data. To facilitate further development of DA techniques for scientific datasets, the ‘Simple Liquid-Argon Track Samples’ dataset used in this study is also published.

97 MATHEMATICS AND COMPUTING↗

The crystal structure of mouse VDAC1 at 2.3 Å resolution reveals mechanistic insights into metabolite gating

The voltage-dependent anion channel (VDAC) constitutes the major pathway for the entry and exit of metabolites across the outer membrane of the mitochondria and can serve as a scaffold for molecules that modulate the organelle. We report the crystal structure of a {beta}-barrel eukaryotic membrane protein, the murine VDAC1 (mVDAC1) at 2.3 {angstrom} resolution, revealing a high-resolution image of its architecture formed by 19 {beta}-strands. Unlike the recent NMR structure of human VDAC1, the position of the voltage-sensing N-terminal segment is clearly resolved. The {alpha}-helix of the N-terminal segment is oriented against the interior wall, causing a partial narrowing at the center of the pore. This segment is ideally positioned to regulate the conductance of ions and metabolites passing through the VDAC pore.

36 MATERIALS SCIENCE↗

SU-E-T-505: CT-Based Independent Dose Verification for RapidArc Plan as a Secondary Check

Purpose: To design and develop a CT-based independent dose verification for the RapidArc plan and also to show the effectiveness of inhomogeneous correction in the secondary check for the plan. Methods: To compute the radiological path from the body surface to the reference point and equivalent field sizes from the multiple MLC aperture shapes in the RapidArc MLC sequences independently, DICOM files of CT image, structure and RapidArc plan were imported to our in-house software. The radiological path was computed using a three-dimensional CT arrays for each segment. The multiple MLC aperture shapes were used to compute tissue maximum ratio and phantom scatter factor using the Clarkson-method. In this study, two RapidArc plans for oropharynx cancer were used to compare the doses in CT-based calculation and water-equivalent phantom calculation using the contoured body structure to the dose in a treatment planning system (TPS). Results: The comparison in the one plan shows good agreement in both of the calculation (within 1%). However, in the other case, the CT-based calculation shows better agreement compared to the water-equivalent phantom calculation (CT-based: -2.8% vs. Water-based: -3.8%). Because there were multiple structures along the multiple beam paths and the radiological path length in the CT-based calculation and the path in the water-homogenous phantom calculation were comparatively different. Conclusion: RapidArc treatments are performed in any sites (from head, chest, abdomen to pelvis), which includes inhomogeneous media. Therefore, a more reliable CT-based calculation may be used as a secondary check for the independent verification.

60 APPLIED LIFE SCIENCES↗

CT based computerized identification and analysis of human airways: A review

As one of the most prevalent chronic disorders, airway disease is a major cause of morbidity and mortality worldwide. In order to understand its underlying mechanisms and to enable assessment of therapeutic efficacy of a variety of possible interventions, noninvasive investigation of the airways in a large number of subjects is of great research interest. Due to its high resolution in temporal and spatial domains, computed tomography (CT) has been widely used in clinical practices for studying the normal and abnormal manifestations of lung diseases, albeit there is a need to clearly demonstrate the benefits in light of the cost and radiation dose associated with CT examinations performed for the purpose of airway analysis. Whereas a single CT examination consists of a large number of images, manually identifying airway morphological characteristics and computing features to enable thorough investigations of airway and other lung diseases is very time-consuming and susceptible to errors. Hence, automated and semiautomated computerized analysis of human airways is becoming an important research area in medical imaging. A number of computerized techniques have been developed to date for the analysis of lung airways. In this review, we present a summary of the primary methods developed for computerized analysis of human airways, including airway segmentation, airway labeling, and airway morphometry, as well as a number of computer-aided clinical applications, such as virtual bronchoscopy. Both successes and underlying limitations of these approaches are discussed, while highlighting areas that may require additional work.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality control for quantitative multicenter whole-body PET/MR studies: A NEMA image quality phantom study with three current PET/MR systems

Purpose: Integrated positron emission tomography/magnetic resonance (PET/MR) systems derive the PET attenuation correction (AC) from dedicated MR sequences. While MR-AC performs reasonably well in clinical patient imaging, it may fail for phantom-based quality control (QC). The authors assess the applicability of different protocols for PET QC in multicenter PET/MR imaging. Methods: The National Electrical Manufacturers Association NU 2 2007 image quality phantom was imaged on three combined PET/MR systems: a Philips Ingenuity TF PET/MR, a Siemens Biograph mMR, and a GE SIGNA PET/MR (prototype) system. The phantom was filled according to the EANM FDG-PET/CT guideline 1.0 and scanned for 5 min over 1 bed. Two MR-AC imaging protocols were tested: standard clinical procedures and a dedicated protocol for phantom tests. Depending on the system, the dedicated phantom protocol employs a two-class (water and air) segmentation of the MR data or a CT-based template. Differences in attenuation- and SUV recovery coefficients (RC) are reported. PET/CT-based simulations were performed to simulate the various artifacts seen in the AC maps (μ-map) and their impact on the accuracy of phantom-based QC. Results: Clinical MR-AC protocols caused substantial errors and artifacts in the AC maps, resulting in underestimations of the reconstructed PET activity of up to 27%, depending on the PET/MR system. Using dedicated phantom MR-AC protocols, PET bias was reduced to −8%. Mean and max SUV RC met EARL multicenter PET performance specifications for most contrast objects, but only when using the dedicated phantom protocol. Simulations confirmed the bias in experimental data to be caused by incorrect AC maps resulting from the use of clinical MR-AC protocols. Conclusions: Phantom-based quality control of PET/MR systems in a multicenter, multivendor setting may be performed with sufficient accuracy, but only when dedicated phantom acquisition and processing protocols are used for attenuation correction.

60 APPLIED LIFE SCIENCES↗

Preliminary results on the feasibility of using ultrasound to monitor intrafractional motion during radiation therapy for pancreatic cancer

Purpose: Substantial intrafraction organ motion during radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor for accurate delivery of RT. The aim of this work is to determine the feasibility of monitoring the intrafractional motion of the pancreas or surrounding structures using ultrasound for RT delivery. Methods: Transabdominal ultrasound (TAUS) and 4DCT data were acquired on ten pancreatic cancer patients during radiation therapy process in a prospective study. In addition, TAUS and MRI were collected for five healthy volunteers. The portal vein (PV) and the head of the pancreas (HP) along with other structures were contoured on these images. Volume changes, distance between the HP and PV, and motion difference between the HP and PV were measured to examine whether PV can be used as a motion surrogate for HP. TAUS images were acquired and processed using a research version of the Clarity autoscan ultrasound system (CAUS). Motion monitoring was performed with the ultrasound probe mounted on an arm fixed to the couch. Video segments of the monitoring sessions were captured. Results: On TAUS, PV is better visualized than HP. The measured mean volume deviation for all patients for the HP and PV was 1.4 and 0.6 ml, respectively. The distance between the HP and PV was close to a constant with 0.22 mm mean deviation throughout the ten breathing phases. The mean of the absolute motion difference for all patients was 1.7 ± 0.8 mm in LR, 1.5 ± 0.5 mm in AP, and 2.3 ± 0.7 mm in SI, suggesting that the PV is a good surrogate for HP motion estimation. By using this surrogate, the HP motion tracking using TAUS was demonstrated. Conclusions: Large intrafractional organ motion due to respiratory and/or bowel motion is a limiting factor in administering curative radiation doses to pancreatic tumors. The authors investigate the use of real-time ultrasound to track pancreas motion. Due to the poor visibility of the pancreas head on an ultrasound image, the portal vein is identified as a surrogate. The authors have demonstrated the feasibility of tracking HP motion through the localization of the PV using TAUS. This will potentially allow real-time tracking of intrafractional motion to justify small PTV-margins and to account for unusual motions, thus, improving normal tissue sparing.

60 APPLIED LIFE SCIENCES↗

Moving metal artifact reduction in cone-beam CT scans with implanted cylindrical gold markers

Purpose: Implanted gold markers for image-guided radiotherapy lead to streaking artifacts in cone-beam CT (CBCT) scans. Several methods for metal artifact reduction (MAR) have been published, but they all fail in scans with large motion. Here the authors propose and investigate a method for automatic moving metal artifact reduction (MMAR) in CBCT scans with cylindrical gold markers. Methods: The MMAR CBCT reconstruction method has six steps. (1) Automatic segmentation of the cylindrical markers in the CBCT projections. (2) Removal of each marker in the projections by replacing the pixels within a masked area with interpolated values. (3) Reconstruction of a marker-free CBCT volume from the manipulated CBCT projections. (4) Reconstruction of a standard CBCT volume with metal artifacts from the original CBCT projections. (5) Estimation of the three-dimensional (3D) trajectory during CBCT acquisition for each marker based on the segmentation in Step 1, and identification of the smallest ellipsoidal volume that encompasses 95% of the visited 3D positions. (6) Generation of the final MMAR CBCT reconstruction from the marker-free CBCT volume of Step 3 by replacing the voxels in the 95% ellipsoid with the corresponding voxels of the standard CBCT volume of Step 4. The MMAR reconstruction was performed retrospectively using a half-fan CBCT scan for 29 consecutive stereotactic body radiation therapy patients with 2–3 gold markers implanted in the liver. The metal artifacts of the MMAR reconstructions were scored and compared with a standard MAR reconstruction by counting the streaks and by calculating the standard deviation of the Hounsfield units in a region around each marker. Results: The markers were found with the same autosegmentation settings in 27 CBCT scans, while two scans needed slightly changed settings to find all markers automatically in Step 1 of the MMAR method. MMAR resulted in 15 scans with no streaking artifacts, 11 scans with 1–4 streaks, and 3 scans with severe streaking artifacts. The corresponding numbers for MAR were 8 (no streaks), 1 (1–4 streaks), and 20 (severe streaking artifacts). The MMAR method was superior to MAR in scans with more than 8 mm 3D marker motion and comparable to MAR for scans with less than 8 mm motion. In addition, the MMAR method was tested on a 4D CBCT reconstruction for which it worked equally well as for the 3D case. The markers in the 4D case had very low motion blur. Conclusions: An automatic method for MMAR in CBCT scans was proposed and shown to effectively remove almost all streaking artifacts in a large set of clinical CBCT scans with implanted gold markers in the liver. Residual streaking artifacts observed in three CBCT scans may be removed with better marker segmentation.

60 APPLIED LIFE SCIENCES↗

Deprotonated Water Dimers: The Building Blocks of Segmented Water Chains on Rutile RuO2(110)

Despite the importance of RuO2 in photocatalytic water splitting and catalysis in general, the interactions of water with even its most stable (110) surface are not well-understood. In this study we employ a combination of high-resolution scanning tunneling microscopy imaging with density functional theory based ab initio molecular dynamics, and we follow the formation and binding of linear water clusters on coordinatively unsaturated ruthenium rows. We find that clusters of all sizes (dimers, trimers, tetramers, extended chains) are stabilized by donating one proton per every two water molecules to the surface bridge bonded oxygen sites, in contrast with water monomers that do not show a significant propensity for dissociation. The clusters with odd number of water molecules are less stable than the clusters with even number, and are generally not observed under thermal equilibrium. For all clusters with even numbers, the dissociated dimers represent the fundamental building blocks with strong intra-dimer hydrogen bonds and only very weak inter-dimer interactions resulting in segmented water chains.

ab initio molecular dynamics↗

4D XCAT phantom for multimodality imaging research

Purpose: The authors develop the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. Methods: Highly detailed whole-body anatomies for the adult male and female were defined in the XCAT using nonuniform rational B-spline (NURBS) and subdivision surfaces based on segmentation of the Visible Male and Female anatomical datasets from the National Library of Medicine as well as patient datasets. Using the flexibility of these surfaces, the Visible Human anatomies were transformed to match body measurements and organ volumes for a 50th percentile (height and weight) male and female. The desired body measurements for the models were obtained using the PEOPLESIZE program that contains anthropometric dimensions categorized from 1st to the 99th percentile for US adults. The desired organ volumes were determined from ICRP Publication 89 [ICRP, ''Basic anatomical and physiological data for use in radiological protection: reference values,'' ICRP Publication 89 (International Commission on Radiological Protection, New York, NY, 2002)]. The male and female anatomies serve as standard templates upon which anatomical variations may be modeled in the XCAT through user-defined parameters. Parametrized models for the cardiac and respiratory motions were also incorporated into the XCAT based on high-resolution cardiac- and respiratory-gated multislice CT data. To demonstrate the usefulness of the phantom, the authors show example simulation studies in PET, SPECT, and CT using publicly available simulation packages. Results: As demonstrated in the pilot studies, the 4D XCAT (which includes thousands of anatomical structures) can produce realistic imaging data when combined with accurate models of the imaging process. With the flexibility of the NURBS surface primitives, any number of different anatomies, cardiac or respiratory motions or patterns, and spatial resolutions can be simulated to perform imaging research. Conclusions: With the ability to produce realistic, predictive 3D and 4D imaging data from populations of normal and abnormal patients under various imaging parameters, the authors conclude that the XCAT provides an important tool in imaging research to evaluate and improve imaging devices and techniques. In the field of x-ray CT, the phantom may also provide the necessary foundation with which to optimize clinical CT applications in terms of image quality versus radiation dose, an area of research that is becoming more significant with the growing use of CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-549: Modeling Relative Biological Effectiveness of Protons for Radiation Induced Brain Necrosis

Purpose: To develop a model of the relative biological effectiveness (RBE) of protons as a function of dose and linear energy transfer (LET) for induction of brain necrosis using clinical data. Methods: In this study, treatment planning information was exported from a clinical treatment planning system (TPS) and used to construct a detailed Monte Carlo model of the patient and the beam delivery system. The physical proton dose and LET were computed in each voxel of the patient volume using Monte Carlo particle transport. A follow-up magnetic resonance imaging (MRI) study registered to the treatment planning CT was used to determine the region of the necrosis in the brain volume. Both, the whole brain and the necrosis volumes were segmented from the computed tomography (CT) dataset using the contours drawn by a physician and the corresponding voxels were binned with respect to dose and LET. The brain necrosis probability was computed as a function of dose and LET by dividing the total volume of all necrosis voxels with a given dose and LET with the corresponding total brain volume resulting in a set of NTCP-like curves (probability as a function of dose parameterized by LET). Results: The resulting model shows dependence on both dose and LET indicating the weakness of the constant RBE model for describing the brain toxicity. To the best of our knowledge the constant RBE model is currently used in all clinical applications which may Result in increased rate of brain toxicities in patients treated with protons. Conclusion: Further studies are needed to develop more accurate brain toxicity models for patients treated with protons and other heavy ions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-207-07: Quantification of Coronary Artery Cross-Sectional Area in CT Angiography Using Integrated Density: A Phantom Study

Purpose: To investigate the feasibility of quantifying the cross-sectional area (CSA) of coronary arteries using integrated density in a physics-based model with a phantom study. Methods: In this technique the total integrated density of the object as compared with its local background is measured so it is possible to account for the partial volume effect. The proposed method was compared to manual segmentation using CT scans of a 10 cm diameter Lucite cylinder placed inside a chest phantom. Holes with cross-sectional areas from 1.4 to 12.3 mm{sup 2} were drilled into the Lucite and filled with iodine solution, producing a contrast-to-noise ratio of approximately 26. Lucite rods 1.6 mm in diameter were used to simulate plaques. The phantom was imaged with and without the Lucite rods placed in the holes to simulate diseased and normal arteries, respectively. Linear regression analysis was used, and the root-mean-square deviations (RMSD) and errors (RMSE) were computed to assess the precision and accuracy of the measurements. In the case of manual segmentation, two readers independently delineated the lumen in order to quantify the inter-reader variability. Results: The precision and accuracy for the normal vessels using the integrated density technique were 0.32 mm{sup 2} and 0.32 mm{sup 2}, respectively. The corresponding results for the manual segmentation were 0.51 mm{sup 2} and 0.56 mm{sup 2}. In the case of diseased vessels, the precision and accuracy of the integrated density technique were 0.46 mm{sup 2} and 0.55 mm{sup 2}, respectively. The corresponding results for the manual segmentation were 0.75 mm{sup 2} and 0.98 mm{sup 2}. The mean percent difference for the two readers was found to be 8.4%. Conclusion: The CSA based on integrated density had improved precision and accuracy as compared with manual segmentation in a Lucite phantom. The results indicate the potential for using integrated density to improve CSA measurements in CT angiography.

60 APPLIED LIFE SCIENCES↗

A versatile machine learning workflow for high-throughput analysis of supported metal catalyst particles

Accurate and efficient characterization of nanoparticles (NPs), particularly regarding particle size distribution, is essential for advancing our understanding of their structure-property relationship and facilitating their design for various applications. In this study, we introduce a novel two-stage artificial intelligence (AI)-driven workflow for NP analysis that leverages prompt engineering techniques from state-of-the-art single-stage object detection and large-scale vision transformer (ViT) architectures. This methodology is applied to transmission electron microscopy (TEM) and scanning TEM (STEM) images of heterogeneous catalysts, enabling high-resolution, high-throughput analysis of particle size distributions for supported metal catalyst NPs. The model's performance in detecting and segmenting NPs is validated across diverse heterogeneous catalyst systems, including various metals (Ru, Cu, PtCo, and Pt), supports (silica (SiO 2 ), γ-alumina (γ-Al 2 O 3 ), and carbon black), and particle diameter size distributions with mean and standard deviations ranging from 1.6 ± 0.2 nm to 9.7 ± 4.6 nm. The proposed machine learning (ML) methodology achieved an average F1 overlap score of 0.91 ± 0.01 and demonstrated the ability to disentangle overlapping NPs anchored on catalytic support materials. The segmentation accuracy is further validated using the Hausdorff distance and robust Hausdorff distance metrics, with the 90th percent of the robust Hausdorff distance showing errors within 0.4 ± 0.1 nm to 1.4 ± 0.6 nm. In conclusion, our AI-assisted NP analysis workflow demonstrates robust generalization across diverse datasets and can be readily applied to similar NP segmentation tasks without requiring costly model retraining.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CdTe Timepix detectors for single-photon spectroscopy and linear polarimetry of high-flux hard x-ray radiation

Single-photon spectroscopy of pulsed, high-intensity sources of hard X-rays — such as laser-generated plasmas — is often hampered by the pileup of several photons absorbed by the unsegmented, large-volume sensors routinely used for the detection of high-energy radiation. Detectors based on the Timepix chip, with a segmentation pitch of 55 μm and the possibility to be equipped with high-Z sensor chips, constitute an attractive alternative to commonly used passive solutions such as image plates. In this report, we present energy calibration and characterization measurements of such devices. The achievable energy resolution is comparable to that of scintillators for γ spectroscopy. Moreover, we also introduce a simple two-detector Compton polarimeter setup with a polarimeter quality of (98 ± 1)%. Finally, a proof-of-principle polarimetry experiment is discussed, where we studied the linear polarization of bremsstrahlung emitted by a laser-driven plasma and found an indication of the X-ray polarization direction depending on the polarization state of the incident laser pulse.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light Detecting and Ranging (LIDAR) for in-situ heliostat optical error assessment

A system and method for optical assessment of a heliostat includes obtaining a point cloud data representing an image of the heliostat; isolating the data; filtering and fitting the filtered heliostat data to a bounding box; translating the heliostat data to a plane to aid in segmentation; segmenting a plurality of facets of the heliostat fitting each of the segmented facets to a respective plane; generating normal vectors characterizing each of the plurality of facets; and calculating a canting angle associated with each respective facet of the plurality of facets. A heliostat with mirrored facets and a scanner are provided. The scanner captures point cloud data representing the heliostat, which is segmented for each facet. Normal vectors characterize the facets and a canting angle is calculated for the respective facet.

Small, Daniel E.↗

Quality and accuracy of cone beam computed tomography gated by active breathing control

The purpose of this study was to evaluate the quality and accuracy of cone beam computed tomography (CBCT) gated by active breathing control (ABC), which may be useful for image guidance in the presence of respiration. Comparisons were made between conventional ABC-CBCT (stop and go), fast ABC-CBCT (a method to speed up the acquisition by slowing the gantry instead of stopping during free breathing), and free breathing respiration correlated CBCT. Image quality was assessed in phantom. Accuracy of reconstructed voxel intensity, uniformity, and root mean square error were evaluated. Registration accuracy (bony and soft tissue) was quantified with both an anthropomorphic and a quality assurance phantom. Gantry angle accuracy was measured with respect to gantry speed modulation. Conventional ABC-CBCT scan time ranged from 2.3 to 5.8 min. Fast ABC-CBCT scan time ranged from 1.4 to 1.8 min, and respiratory correlated CBCT scans took 2.1 min to complete. Voxel intensity value for ABC gated scans was accurate relative to a normal clinical scan with all projections. Uniformity and root mean square error performance degraded as the number of projections used in the reconstruction of the fast ABC-CBCT scans decreased (shortest breath hold, longest free breathing segment). Registration accuracy for small, large, and rotational corrections was within 1 mm and 1 degree sign . Gantry angle accuracy was within 1 degree sign for all scans. For high-contrast targets, performance for image-guidance purposes was similar for fast and conventional ABC-CBCT scans and respiration correlated CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-100: The Combination of Deformable Image Registration and Regions-Of-Interest Mapping Technique to Accomplish Accurate Dose Calculation On Cone Beam Computed Tomography for Esophageal Cancer

Purpose: We introduce a new method combined with the deformable image registration (DIR) and regions-of-interest mapping (ROIM) technique to accurately calculate dose on daily CBCT for esophageal cancer. Methods: Patients suffered from esophageal cancer were enrolled in the study. Prescription was set to 66 Gy/30 F and 54 Gy/30 F to the primary tumor (PTV66) and subclinical disease (PTV54) . Planning CT (pCT) were segmented into 8 substructures in terms of their differences in physical density, such as gross target volume (GTV), venae cava superior (SVC), aorta, heart, spinal cord, lung, muscle and bones. The pCT and its substructures were transferred to the MIM software to readout their mean HU values. Afterwards, a deformable planning CT to daily KV-CBCT image registration method was then utilized to acquire a new structure set on CBCT. The newly generated structures on CBCT were then transferred back to the treatment planning system (TPS) and its HU information were overridden manually with mean HU values obtained from pCT. Finally, the treatment plan was projected onto the CBCT images with the same beam arrangements and monitor units (MUs) to accomplish dose calculation. Planning target volume (PTV) and organs at risk (OARs) from both of the pCT and CBCT were compared to evaluate the dose calculation accuracy. Results: It was found that the dose distribution in the CBCT showed little differences compared to the pCT, regardless of whether PTV or OARs were concerned. Specifically, dose variation in GTV, PTV54, PTV66, SVC, lung and heart were within 0.1%. The maximum dose variation was presented in the spinal cord, which was up to 2.7% dose difference. Conclusion: The proposed method combined with DIR and ROIM technique to accurately calculate dose distribution on CBCT for esophageal cancer is feasible.

60 APPLIED LIFE SCIENCES↗