Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Conduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Cracking in first ramp to power of standard versus high thermal conductivity UO2 pellets via internal nuclear heating

Advanced fuel designs that incorporate thinner fuel UO2 pellets interspaced by high thermal conductivity inserts have been proposed, with the primary goals of reducing peak centerline temperatures and temperature gradients across fuel pellets and enhancing heat transfer from the fuel to the coolant. An initial series of experiments has been performed on this design, including laboratory experiments and a series of experiments using the Idaho National Laboratory (INL) Transient Reactor Test (TREAT) Facility, the latter of which compared thermal gradient driven fracture of standard pellet designs with that in the proposed advanced fuel design. Although reducing fracture is not the primary objective of the new fuel design, the lower thermal gradients are expected to reduce fracture, so it can serve as an indicator of the thermal behavior of this fuel in the reactor. The in-reactor tests were conducted at multiple linear heat generation rates and confirm the expected result that fracture in both the standard and advanced fuel pellets occurs during the first ramp to power in standard light-water reactor conditions. Post-irradiation examination of the experiment material was performed and included quantification of the extent of fracture in the fuel pellets. It was found that the advanced-design pellets reduce the extent of fracture in a statistically significant way. This confirms the expected behavior predicted by two-dimensional axisymmetric models of this experiment. This study is an important first experimental confirmation of the efficacy of the proposed inserts for achieving their desired effect on the thermal behavior of the fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TEM Characterization of Neutron Irradiated HfAl3-Al Composite Specimens

Particles comprised of a thermal neutron absorbing material (HfAl3) are dispersed in a metal matrix material with high thermal conductivity (aluminum) to conduct the heat generated by neutron capture away from the fuel and materials. This metal matrix composite is very promising for use as a conduction-cooled neutron absorber and has the potential to be useful as a shroud or heat sink for testing advanced fast reactor fuels and materials in an existing thermal reactor. To design and optimize the absorber block system for advanced reactor designs, fundamental understanding of the irradiation effect on material properties is necessary. This dataset contains TEM characterization results of neutron irradiated HfAl3-Al composite specimens. It is focused on the irradiation induced defects (dislocation lines and loops) characterization using the on-zone axis bright field STEM technique. This data was collected using a FEI Tecnai G2 F30 S/TEM at the Microscopy and Characterization Suite (MaCS), Center for Advanced Energy Studies (CAES).

Guillen, Donna↗

TEM Characterization of Neutron Irradiated HfAl3-Al Composite Specimens

Particles comprised of a thermal neutron absorbing material (HfAl3) are dispersed in a metal matrix material with high thermal conductivity (aluminum) to conduct the heat generated by neutron capture away from the fuel and materials. This metal matrix composite is very promising for use as a conduction-cooled neutron absorber and has the potential to be useful as a shroud or heat sink for testing advanced fast reactor fuels and materials in an existing thermal reactor. To design and optimize the absorber block system for advanced reactor designs, fundamental understanding of the irradiation effect on material properties is necessary. This dataset contains TEM characterization results of neutron irradiated HfAl3-Al composite specimens. It is focused on the irradiation induced defects (dislocation lines and loops) characterization using the on-zone axis bright field STEM technique. This data was collected using a FEI Tecnai G2 F30 S/TEM at the Microscopy and Characterization Suite (MaCS), Center for Advanced Energy Studies (CAES).

Guillen, Donna↗

Device and method for measuring thermal conductivity of thin films

A device and method are provided for measuring the thermal conductivity of rigid or flexible, homogeneous or heterogeneous, thin films between 50 .mu.m and 150 .mu.m thick with relative standard deviations of less than five percent. The specimen is sandwiched between like material, highly conductive upper and lower slabs. Each slab is instrumented with six thermocouples embedded within the slab and flush with their corresponding surfaces. A heat source heats the lower slab and a heat sink cools the upper slab. The heat sink also provides sufficient contact pressure onto the specimen. Testing is performed within a vacuum environment (bell-jar) between 10.sup.-3 to 10.sup.-6 Torr. An anti-radiant shield on the interior surface of the bell-jar is used to avoid radiation heat losses. Insulation is placed adjacent to the heat source and adjacent to the heat sink to prevent conduction losses. A temperature controlled water circulator circulates water from a constant temperature bath through the heat sink. Fourier's one-dimensional law of heat conduction is the governing equation. Data, including temperatures, are measured with a multi-channel data acquisition system. On-line computer processing is used for thermal conductivity calculations.

Amer, Tahani R.↗

Computationally inexpensive part-scale thermal history of additive friction-stir deposition

This study presents an analytical model for steady-state power generation and tool heat loss in additive friction-stir deposition (AFSD), developed to enable part-scale thermal simulation while remaining computationally inexpensive. The model predicts total generated power, yielding 3.7–4.7 kW across deposition temperature setpoints of 400–460 °C for the deposition of AA6061 with a Be-Cu tool. This corresponds to 90–95% of the reported spindle power. Tool heat loss is experimentally determined by calibrating a steady-state energy balance between the generated power, the substrate-deposition thermal gradient, and a temperature dependent tool heat loss term: q tool (T) = a + b (T - 400°C) with a = 2.7 x 10 6 Wm -2 and b = 9.5 x 10 3 Wm -2 K -1 . The calibration indicates that about 69% of the generated heat is conducted into the tool for this configuration, which is much higher than previously reported. The calibrated heat-source is implemented in finite element software (Adamantine) to simulate the transient thermal history of a 100 cm 3 representative build in 8 min on a standard desktop (at 0.635 mm build-height resolution). For the first three layers, the substrate temperatures between simulation and experiment are within 10% mean absolute percentage error. Sensitivity analysis indicates that uncertainties in average deposition temperature and deformation localization (stir-zone geometry, depth, and spatial dependance of strain-rate and flow stress) dominate model variance, motivating additional experimental verification.

Additive Friction-Stir Deposition↗

Design and construction of high-sensitivity, infrared bolometers for operation at 300 mK

The design and construction of 300-mK composite bolometers developed for millimeter-wave astronomical observations are described. Graphite fibers are used as the electrical leads for the thermistor to reduce the thermal conductance and heat capacity associated with the leads. A mechanical suspension made of Nylon fibers provides the required thermal conductance. Electrical noise equivalent powers below 1 x 10 exp -16 W/sq rt Hz have been achieved for detectors with thermal time constants of 11 ms. The detectors were installed in a millimeter-wave photometer and used to perform observations of the cosmic microwave background from a balloonborne platform. The flight performance was consistent with the measured laboratory properties.

Alsop, D. C.↗

Experimental Investigation of Jet Impingement Heat Transfer Using Thermochromic Liquid Crystals

Jet impingement cooling of a hypersonic airfoil leading edge is experimentally investigated using thermochromic liquid crystals (TLCS) to measure surface temperature. The experiment uses computer data acquisition with digital imaging of the TLCs to determine heat transfer coefficients during a transient experiment. The data reduction relies on analysis of a coupled transient conduction - convection heat transfer problem that characterizes the experiment. The recovery temperature of the jet is accounted for by running two experiments with different heating rates, thereby generating a second equation that is used to solve for the recovery temperature. The resulting solution requires a complicated numerical iteration that is handled by a computer. Because the computational data reduction method is complex, special attention is paid to error assessment. The error analysis considers random and systematic errors generated by the instrumentation along with errors generated by the approximate nature of the numerical methods. Results of the error analysis show that the experimentally determined heat transfer coefficients are accurate to within 15%. The error analysis also shows that the recovery temperature data may be in error by more than 50%. The results show that the recovery temperature data is only reliable when the recovery temperature of the jet is greater than 5 C, i.e. the jet velocity is in excess of 100 m/s. Parameters that were investigated include nozzle width, distance from the nozzle exit to the airfoil surface, and jet velocity. Heat transfer data is presented in graphical and tabular forms. An engineering analysis of hypersonic airfoil leading edge cooling is performed using the results from these experiments. Several suggestions for the improvement of the experimental technique are discussed.

Dempsey, Brian Paul↗

Characterizing Thermal Properties of Melting Te Semiconductor: Thermal Diffusivity Measurements and Simulation

Tellurium is an element for many II-VI and I-III-VI(sub 2) compounds that are useful materials for fabricating many devices. In the melt growth techniques, the thermal properties of the molten phase are important parameter for controlling growth process to improve semiconducting crystal quality. In this study, thermal diffusivity of molten tellurium has been measured by a laser flash method in the temperature range from 500 C to 900 C. A pulsed laser with 1064 nm wavelength is focused on one side of the measured sample. The thermal diffusivity can be estimated from the temperature transient at the other side of the sample. A numerical simulation based on the thermal transport process has been also performed. By numerically fitting the experimental results, both the thermal conductivity and heat capacity can be derived. A relaxation phenomenon, which shows a slow drift of the measured thermal conductivity toward the equilibrium value after cooling of the sample, was observed for the first time. The error analysis and the comparison of the results to published data measured by other techniques will be discussed.

Zhu, Shen↗

Characterizing Thermal Properties of Melting Te Semiconductor: Thermal Diffusivity Measurements and Simulation

Tellurium is an element for many II-VI and I-III-VI(sub 2) compounds that are useful materials for fabricating many devises. In the melt growth techniques, the thermal properties of the molten phase are important parameter for controlling growth process to improve semiconducting crystal quality. In this study, thermal diffusivity of molten tellurium has been measured by a laser flash method in the temperature range from 500 C to 900 C. A pulsed laser with 1064 nm wavelength is focused on one side of the measured sample. The thermal diffusivity can be estimated from the temperature transient at the other side of the sample. A numerical simulation based on the thermal transport process has been also performed. By numerically fitting the experimental results, both the thermal conductivity and heat capacity can be derived. A relaxation phenomenon, which shows a slow drift of the measured thermal conductivity toward the equilibrium value after cooling of the sample, was observed for the first time. The error analysis and the comparison of the results to published data measured by other techniques will be discussed in the presentation.

Zhu, Shen↗

A Thermal Analysis of a Hot-Wire Probe for Icing Applications

This paper presents a steady-state thermal model of a hot-wire instrument applicable to atmospheric measurement of water content in clouds. In this application, the power required to maintain the wire at a given temperature is used to deduce the water content of the cloud. The model considers electrical resistive heating, axial conduction, convection to the flow, radiation to the surroundings, as well as energy loss due to the heating, melting, and evaporation of impinging liquid and or ice. All of these parameters can be varied axially along the wire. The model further introduces a parameter called the evaporation potential which locally gauges the maximum fraction of incoming water that evaporates. The primary outputs of the model are the steady-state power required to maintain a spatially-average constant temperature as well as the variation of that temperature and other parameters along the wire. The model is used to understand the sensitivity of the hot-wire performance to various flow and boundary conditions including a detailed comparison of dry air and wet (i.e. cloud-on) conditions. The steady-state power values are compared to experimental results from a Science Engineering Associates (SEA) Multi-Element probe, a commonly used water-content measurement instrument. The model results show good agreement with experiment for both dry and cloud-on conditions with liquid water content. For ice, the experimental measurements under read the actual water content due to incomplete evaporation and splashing. Model results, which account for incomplete evaporation, are still higher than experimental results where the discrepancy is attributed to splashing mass-loss which is not accounted in the model.

Thermal Analysis↗

Simulation of flame acceleration and deflagration-to-detonation transition with heat transfer in HE product and fractured HE

A simple heat transfer model has been developed for high explosives. For the gaseous high explosive (HE) product, the Smargorinsky eddy viscosity model has been adopted for estimating the turbulent thermal conductivity. Convective heat transfer in the fractured solid HE is modeled as the effective thermal conduction in the porous media, which is equivalent to the enthalpy flux carried by the velocity determined by Darcy’s law with Forchheimer term.Other features of the model include a multi-reaction chain, equation-of-state for each species involved, and a two-phase hotspot model. Test calculations are performed with various initial disturbances. Onset and progress of flame acceleration (FA) and chemical reactions are strongly affected by the heat transfer and initial disturbance. Staged development of FA also affirms the necessity of modeling based on a multi-reaction chain. When conditions warrant,e.g., stronger initial disturbance, FA evolves to deflagration-to-detonation transition (DDT),demonstrating automatic capture of the DDT.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Heat-Transfer and Friction Measurements with Variable Properties for Airflow Normal to Finned and Unfinned Tube Banks

A single-line correlation of both the heat-transfer and pressure- drop data for electrically heated unfinned tubes is obtained by evaluating the density in the Reynolds number, specific heat, thermal conductivity, and viscosity at the film temperature, and the density in the friction coefficient at the bulk temperature. The heat-transfer data for finned tubes also exhibit an effect of physical-property variation which is removed by evaluating all properties, including density, at the primary surface temperature, and using k* = 0.015 square root of T/530 for the thermal conductivity of air where T is the absolute temperature. The pressure drop for finned tubes is correlated by the use of bulk density in both the Reynolds number and friction coefficient. The data reported are for Reynolds numbers from 2000 to 35,000, surface temperatures from 600 to 1400 R, and an air inlet temperature of 530 R.

Ragsdale, Robert G.↗

Thermophysical properties of parahydrogen from the freezing liquid line to 5000 R for pressures to 10000 psia

The tables include entropy, enthalpy, internal energy, density, volume, speed of sound, specific heat, thermal conductivity, viscosity, thermal diffusivity, Prandtl number, and the dielectric constant for 65 isobars. Quantities of special utility in heat transfer and thermodynamic calculations are also included in the isobaric tables. In addition to the isobaric tables, tables for the saturated vapor and liquid are given, which include all of the above properties, plus the surface tension. Tables for the P-T of the freezing liquid, index of refraction, and the derived Joule-Thomson inversion curve are also presented.

Mccarty, R. D.↗

Thermophysical properties of the Ghareb formation relevant for nuclear waste disposal

The Ghareb formation, a shallowly buried porous chalk in Israel, is currently a candidate for nuclear waste disposal. The potential repository is somewhat unique for its host rock and emplacement in shallow (500 m) engineered large diameter boreholes. Herein, the thermal properties of the Ghareb are determined to support design and performance assessment; the relevant properties measured are thermal conductivity, specific heat capacity, thermal diffusivity, and thermal expansion coefficient along with their relationship with varying temperature. For the temperature range of 40 to 275 °C, the thermal conductivity ranges from 0.30 to 1.10 W/m·K, the thermal diffusivity ranges from 0.20 to 0.72 mm 2 /s, and volumetric heat capacity ranges from 0.86 to 2.00 MJ/m 3 ·K. Thermal strain measurements were used to estimate the linear thermal expansion coefficient to be 6·10 –4 –9·10 –2 °C -1 from 40 to 300 °C. These measured properties were used in a thermomechanical model to estimate near-field stresses an hour and 10 years after waste emplacement; the borehole was found to be stable. Thermal loading after 10 years was predicted to elevate local pore pressures by 1–1.5 MPa. The laboratory measurements coupled with analyses are the first attempts at performance assessment characterization for this first of its kind potential repository setting with this chosen host rock.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A 2.2 sq m /24 sq ft/ self-controlled deployable heat pipe radiator - Design and test

An all heat pipe, deployable radiator has been developed which can effectively control pumped fluid loop temperatures under varying loads using variable conductance panel heat pipes. The 2.2 sq m (24 sq ft) aluminum panel can be coupled to either a fluid header or a flexible heat pipe header capable of transporting 850 watts in a 90-deg bent configuration. Test results support the feasibility of using this system to passively control Freon-21 loop temperatures.

Edelstein, F.↗

Vibration-Heating in ADR Kevlar Suspension Systems

The cryogenics group at NASA's Goddard Space Flight Center has a long-standing development and test program for laboratory and space-flight adiabatic demagnetization refrigerators (ADRs). These devices are used to cool components to temperatures as low as 0.05 K. At such low temperatures the ADR systems can provide a few micro-Watts of cooling power, so it is important to minimize the conduction of heat to these cold stages from the surroundings. The cold ADR elements are held in place by thin tensioned strings made of Kevlar, chosen for its high strength and stiffness and low thermal conductivity. During laboratory testing, we have observed that occasional significant additional heat loads on the coldest ADR stages correlate with unusually high vibration levels in the cryostat due to a noisy mechanical cryocooler. We theorized that this heat results from plastic deformation of the Kevlar fibers and frictional interactions among them, driven by the cryostat vibrations. We describe tests and calculations performed in attempt to confirm this source of the heating, and we discuss possible strategies to reduce this effect in future ADR suspension systems.

Vibration-heating↗

Development of a cryocooler conduction-cooled 650 MHz SRF cavity operating at ~10 MV/m cw accelerating gradient

SRF cavities for particle acceleration are conventionally operated immersed in a bath of liquid helium at 4.2 K and below. Although this cooling configuration is practically and economically viable for large scientific accelerator installations, it may not be so for smaller accelerators intended for industrial applications such as the treatment of wastewater, sludge, flue gases, etc. In this paper, we describe a procedure to operate SRF cavities without liquid helium that can be used to construct electron-beam sources for industrial applications of electron irradiation (1-10 MeV electron energy). In this procedure, an elliptical single-cell 650 MHz niobium-tin coated niobium cavity is coupled to a closed-cycle 4.2 K cryocooler using high purity aluminum thermal links. The cryocooler conductively extracts heat (RF dissipation) from the cavity without requiring liquid helium around the cavity. We present construction details of this cryocooler conduction-cooling technique and systematic experiments that have demonstrated ~10 MV/m cw gradient on the cavity. By straightforward scaling up the cavity length and number of cryocoolers, the technique will provide the complete range of 1-10 MeV electron energy for industrial applications.

43 PARTICLE ACCELERATORS↗